Home
Sign Installation Manual
Contents
1. PoE injector Power over Ethernet Ethernet CAT5 cable Building wall 300 foot maximum length NOTE Only one access point is required in a multiple master sign network however each master sign must have a bridge unit Figure 33 Overview of connecting multiple master signs with the wireless WiFi option EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 35 CONNECTING SIGNS CONNECTIVITY OPTION OVERVIEW Fiber optic network option The following diagram is a guide to the fiber optic network pathway and components Using the Fiber Optic Ethernet option you can connect the sign to your Ethernet network or to a computer with an Ethernet cable To use this option your network must be using the TCP IP protocol This is a direct connection used to install the sign over 300 feet from the network or computer If you are using this type of connection permanently make sure the fiber optic cable is installed inside weather tight conduit Rear of sign see note Ethernet strain l Building wall relief connector Network or computer running Ooh Media software y DLL LA ZZIZ LLL A A N 25ft outdoor Ethernet Ethernet CAT5E cable CATSE cable Fiber optic enclosure with Fiber optic Ethernet converter Fiber optic Ethernet converter Note Network Router can be used between Fiber optic Ethernet converter and computer ST ST multimode fiber optic cabling suppli
2. SF CK SY Uy ED d o xy eS Le Figure 43 Install the strain relief connector or weather tight conduit 5 Route the Ethernet cable through the cover plate and plug it into the Ethernet port from the sign s PoE injector Plug the sensor s cable into the box connector port the connector i only fits one way on the bottom of the sign controller gt Ethernet port Ethernet port i connectivity from PoE gt USB port i not used B Box connector sensor II A J B Ethernet cable from Fiber Optic Box If applicable temperature light sensor cable Figure 44 PoE injector connection EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 43 CONNECTING SIGNS CONNECT THE SIGN S CONNECTIVITY OPTION 6 Secure the cover plate to the junction box being careful not to pinch or crimp the cable A 9 O Minimum cable bend fadius is 1 inch O A Carefully pull the slack out of the cables when placing the cover plate back onto the sign B Secure the cover plate to the sign C Tighten each compression nut until they are snug around the cable VV VV NN NN YN Y Y YN Compression nut Figure 45 Securing the cover plate Note Route the cable s downward from the strain relief connector s directing water condensation build up to flow away from the sign s cable entry point 44 EZViEW X MODULAR CASE 20MM AND 23MM
3. light sensor If you do not have either one of these optional sign accessories go to Connectivity option overview on page 33 e Connect a master and slave sign optional on page 28 e Temperature Light sensor optional on page 30 e Connectivity option overview on page 33 e Connect the sign s connectivity option on page 37 e Setup the sign to communicate on your network on page 45 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 27 CONNECTING SIGNS CONNECT A MASTER AND SLAVE SIGN OPTIONAL Connect a master and slave sign optional When signs are connected in a master slave configuration they will display the same messages at the same time Master and slave signs must be the same size For example if the master sign is 32x96 pixels then each connected slave sign must be 32x96 pixels When multiple signs are used to create a network of message centers the signs will be factory configured as a master sign or a slave sign Master signs are directly controlled with the messaging computer or network Slave signs are controlled by the master sign it is connected to gt Connecting a master and slave sign 1 Identify the master and slave signs Master sign olave sign Figure 19 Sign identification 2 Atthe back of the master sign detach the LVDS cable from the back of the sign 7O Remove the LVDS cable Figure 20 L VDS cable tie wrap 3 Route the LVDS c
4. 50 9 10 11 12 13 14 At the login prompt type admin for the Username and Password click OK Connect to 192 168 1 1 Figure 57 Wireless Access Point login prompt In the left menu area click Wireless and then click Site Survey pe Management Wireless Site Survey TCPAP Settings Wireless Basic Setlings An Tine paga provisa tool bo scars Che wisis rotuecak f any Acco Fm or ECTS we fennel a cod ehaes meet d manuals wir chant mide st enabled epo Signal strength ae AMS l 7 LL MAC Address Click the Refresh button to see current information Figure 58 Wireless site survey window Look in the BSSID column for the Access Point s MAC address recorded in Step 6 Look at the value in the Signal column This represents the signal strength on a scale of 1 100 where 100 is the strongest signal strength Make sure the front of the Bridge s is facing toward the Access Point and there is a clear line of sight between them Adjust the position of the units until you receive the strongest signal strength Mount the Bridge s never to the sign and Access Point at the location you receive the strongest signal Install sign software on the computer that will be used to communicate with the sign refer to Set up the sign to communicate on your network on page 45 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SI
5. Figure 54 PoE injector Graphic shown is representation only 2 Plug an Ethernet cable from your computer or network router into the Network port of the PoE injector 3 Plug the DC inlet of the power adapter into the DC 48V port of the PoE injector and the other end into a power socket in the wall 4 Open a web browser type IP 129 168 1 231 in the Address bar and press the Enter key 5 At the login prompt type admin for the Username and Password click OK Figure 55 Wireless Access Point login prompt 6 Record the MAC address Jh Wireless Accere Point SETUP MENU Microsoft Intereet Explorer Log your MAC Address for reference later during the Site Survey MAC Address Management Access Point Status TCP IP Settings Wireless Ther page shear tea gumeni alaba nd goes hane preng of tihe dee APH iu Disabled APL Dira wa Bssm ODE Su Aria IP Froieral Ford lf IF Address mill Tabari Mak DIDI BID Teefyulg Gateway 0000 Ducr buted OO ra hd Pe Figure 56 Wireless Access Point setup menu 7 Move the Access Point to the selected mounting location facing the direction of the sign 8 At the computer open a web browser and type the Access Point s IP address 192 168 1 2 unless it was changed in the Address bar EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 49 CONNECTING SIGNS SET UP THE SIGN TO COMMUNICATE ON YOUR NETWORK
6. AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX IDENTIFY FIND AND CHANGE AN IP ADDRESS ad coh Media 3 File Sign View Language Tools Help Select your sign x 9 Default Display 144 x 432 mss M Schedule Figure 14 Sign selection ooh Media 3 Click the Set IP button Commands to Sign o set Time and Date e Synchronize with the PC ClearMemoy Set to EXA HH MM 55 Click Set IP fof MM IDD TYTY Change Password Send Figure 15 Command button Enter the sign s new IP address and Subnet Mask click Send Commands to Sign Commands to Sig2 XJ Clear Memory Eoo decimals in the IP address are in the correct position Set Ip rc did Change Password Enter 255 255 0 0 in the Subnet Mask IT Confirm the decimals are in the correct position L Set Time and Date IP Address Enter the new IP address Confirm the Click Send Figure 16 Setting the new IP address The sign will reboot Go to the sign and confirm the new IP address appears on the sign s display during start up If applicable disconnect the sign from the computer and reconnect the sign to the permanent sign connectivity connection established in Connect the sign s connectivity option on page 37 STEP 4 Changing the computer s IP address back to the original settings Contact your network administrator for your computer s original settings an
7. Connection A Right click Local Area Connection Es 9 Networl qe VLA Rh ne Disable Status Diagnose Bridge Connections Create Shortcut r Delete Delete Rename Properties Figure 51 Local area connection B Select Properties 4 Select Internet Protocol Version 4 TCP IPv4 and click the Properties button Y Local Area Connection Properties s Networking Connect using amp VIA Rhine Il Compatible Fast Ethemet Adapter This connection uses the following Rems iv 0 Client for Microsoft Networks vl 005 Packet Scheduler v fS File and Printer Sharing for Microsoft Networks Iv 4 Intemet Protocol Version amp TCP IPvEl v DEN RE HE TCP IPv4 A Select Internet Protocol Version 4 TCP IPv4 W 4 Link Layer Topology Discovery Mapper VO Driver W 4 Link Layer Topology Discovery Responder sra Install B Click Properties button Figure 52 Local area connection properties EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 47 CONNECTING SIGNS SET UP THE SIGN TO COMMUNICATE ON YOUR NETWORK 5 Inthe Internet Protocol Version 4 TCP IPv4 Properties dialog select Use the following IP address and enter the following Internet Protocol Version 4 TCP IPvi Properties V General Alternate Configuration You can get IP settings ass
8. Connection l n Repair Wizard Bridge Connections s Create Shortcut New Rename ammreur B Select Properties Figure 48 Local area connection 5 Select Internet Protocol TCP IP and click the Properties button 6 4 Local Area Connection Properties General Authentication Advanced Connect using E Intel R PRO 1000 MT Network Con This connection uses the following items E Client for Microsoft Networks a File and Printer Sharing for Microsoft Networks vi 2005 Packet Scheduler Y MA A Select Internet Protocol TCP IP reas B Click Properties button Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or no connectivity Figure 49 Local area connection properties In the Internet Protocol TCP IP Properties dialog select Use the following IP address and enter the following Internet Protocol TCP IP Properties n General A Click Use the following IP address You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings B Enter the following Obtain an IP address autamaticall E IP address 1
9. JA eal mm 11 Sign installation guidelines and requirements iissis mmm 12 A C ERBEN RUE HER IEAA RE de Ree oe Sd wd eee 12 Meno TOHLIESTRO DES escasa opaohrid ud DUrETEU LLL TSRST O SU T IP REP E REN 13 Vertagon regen DES OI e RULES EUER QOL ESQ RO RESO ae a DURER E ae RE Eds 14 Recommended mounting Drackels mcr rr cri rr ratas oe dts 15 A BU arrienda 16 Monument installation single sided enclosure iisss mmm 17 Monument installation double sided enclosure a a dec oHG Ro eR eae dew k CRUCE SCR de ER RU e 18 Monument installation view from the front resoria cde or ECHO CERE CARERE QR IC Irc ds 19 Poe Mound MSN pr daban titan 20 Install the sign to the sign structure 1 ccc treet nett ener eben settee ett meme 21 ELECTRICAL INSTALLATION VRP CLP ELA Pa dorada ee PICCHHC al NStallaUOMMOGUIFCINCUNG iad aura RA awd a ia UA ries pde 23 Connect power OMe SION aea ners ga dot alae a vae ane ga dior tae a art dpa a dd Ea i ne eg a ee et 25 Eds OUO SQW spo ca DOE E OE DOR A IA 26 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 3 CONNECTING SIGNS 5 rios doas RO RUE COR d 03 2 Arp AOE USO nse azi Connect a Masterand Slave sign 0PU0nal sd d eae de oie dto d eee eod doe dne vex eto oce eto doe 20 Temperature bgnbsensor O DUONG cusa picante Roscoe Y Ace Cie docct e e canet Pre dn car qt lo me Rb 30 Temperature light sensor installation req
10. air flow Cooler air flow DO NOT allow water from the above ID Sign fascia trim or i flashing to drip directly onto ff D S Ig n the seams of the sign door If the structure above the sign does not extend out Minimum past the sign s door seams Hot air clearance install flashing to the DO NOT allow water to pool 1 Inch structure gather underneath or on top of the sign Always create a pathway for water to escape Minimum E clearance x Air Duct Ventilation installation for wall mounted signs 6 Inches lt q m e Provide 3 5 square inches of ventilation obstruction free space for every 1 square foot of sign per face Consult the Ventilation Requirements Table e Ventilation air ducts MUST be installed across the top and bottom of the sign at evenly spaced intervals e Evenly spaced vents help maintain a consistent air flow around the sign Cool air clearance Use 7 square inches if sign height exceeds 7 feet 1 Inch Figure 8 Ventilation requirements around a wall mounted sign 16 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Monument installation single sided enclosure If there is an obstruction on the outside of the display as in a monument style installation care must be taken to assure that it is able to cool Air ducts must be used in the monument to allow air t
11. dot on ades dius dees DR DE ERE S 60 Identify find and change an IP address e cos d net ROC A EDI OR ne X Ce UO e De ED A e t eO ee RR 61 akon rH ri ari anio o 69 Connadre te ACCess Polaris 69 Configure the BIGGS arras d ace pe e e pda e eb etn ias 72 HVS Tall ACHR STAG UNS ideato DUE ae terr dert DNE arsed weg Rade ie av d a eee Vel feles 13 Changing the IP address for an Access Point or Bridge iiim 74 TOUPIES NOON SIC COMM CCU UID rotate encanto Seley oro ie era e DM raed en eur eee ia iia ad 15 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A Introduction This manual will guide installers through the sign installation procedure The installation procedure is divided into three separate procedures e Mechanical installation on page 11 e Electrical installation on page 23 e Connecting signs on page 27 sign connectivity and optional sign accessories Related documents CC INN 1181610201 ooh Media Quick Start This quick start provides instructions for quickly getting messages to your sign using ooh M edia TechMemo Preventing Electrostatic Describes the precautions to take to protect electronic components from ESD 305 0005 Discharge ESD Damage damage ous Sign Ventilation Describes the required ventilation for an LED sign 411 0001 3 i gn Safety High voltage WARNING Hazardous voltage Contact with high voltage may cause death or serious injury Always remove power from
12. downward from the strain relief connector s directing water condensation build up to flow away from the sign s cable entry points EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 29 CONNECTING SIGNS TEMPERATURE LIGHT SENSOR OPTIONAL Temperature Light sensor optional When properly installed the temperature light sensor relays signals to the sign s controller board that indicate the accurate ambient temperature near the sign as well as current light levels for proper dimming of the sign s display 10 screw clearance mounting 1 2 inch to 3 4 inch Light sensor Factory installed strain relief connector do not remove Compression nut r Rubber enclosure gasket UB Enclosure nut Compression gasket E Feedthru body Figure 25 Temperature light sensor Temperature light sensor installation requirements Notice Failure to follow the temperature light sensor install requirements may cause intermittent or inaccurate operation and will not be covered by the warranty e Vents on temperature light sensor must point downward e Do NOT attach temperature light sensor directly to the sign e The temperature light sensor cable must have a water tight seal at the entry point of the sign e Do NOT install near sprinklers or water fountains 30 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONN
13. of the power adapter into the DC 48V port of the PoE injector and the other end into a power socket in the wall Change the IP address on the computer 1 Atthe computer click the Start button and then Connect To gt Show All Connections 7 Internet mail L ECO Dad nbn Calculator 3 e gi T peces E Iustrat s P Lag ofr Lo Shut Dorm Figure 23 Windows start menu EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 15 16 APPENDIX WIFI SETUP GUIDE 2 In the Network Connections window right click Local Area Connection and choose Properties Network Connections File Edit View Favorites Tools Advanced Help gt d Search li Folders Address Network Connections LAN or High Speed Internet p meer Disable Status Repair Wizard Bridge Connections ll Create Shortcut New Rename Connecti Properties Figure 24 Network Connections screen Click Internet Protocol TCP IP and then click the Properties button 4 Local Area Connection Properties General Authentication Advanced Connect using E Intel R PRO 1000 MT Network Con This connection uses the following items T E Client for Microsoft Networks a File and Printer Sharing for Microsoft Networks r QoS Packet Scheduler M Description Transmission Control Protocol Intemet Protocol The default wide area network proto
14. s ground lug 2 Route and secure the ground wire pathway to the grounding rod grounding electrode location 3 Pound the ground rod into the ground and secure the ground wire to it Verify the connections at the sign and the ground rod are secured Earth Grounding Outdoor Signs Adaptive DISFLAY SOLUTIONS Signs MUST BE EARTH GROUNDED in accordance with Article 250 of the National Electrical Code NEC and in accordance with local codes Adaptive requires ground res stance of less than 10 ohms Verification of ground resistance is essential The sign must be properly grounded or the warranty will be void If you have any questions consult a certified electrician Grounding electrode grounding rod Foundation Protect the grounding electrode against physical damage Size of ground rod must be in accordance with national and local electrical codes For illustration purposes only Not drawn to scale Document Mo 97107008 rev Figure 18 Earth grounding the sign 26 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A Connecting signs The following section describes how to connect to the sign using one of two connectivity Ethernet and WiFi options installing a temperature light sensor optional and connecting slave signs to master signs optional If you are installing a master slave sign configuration always make that connection first and then if applicable the temperature
15. sign must have a water tight seal m POWER JUNCTION BOX ii electrical wiring conduit into one of the 7 8 inch conduit holes The connection must have a E LABEL Specific sign information such as model number serial number and electrical ratings 8 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A EQUIPMENT DESCRIPTION SIGN EXTERIOR Open the sign case Access the inside of the EzView sign by opening the case doors Each case opens from the front Case doors are secured to the sign case with one hex head screw located in the top center of each display board WARNING Hazardous voltage Contact with high voltage may cause death or serious injury Remove power at the source prior to opening the sign Do not open the sign case doors until the sign is fully installed on the sign structure otherwise the sign may tip causing serious injury and or damage the sign Failure to comply will void the sign s warranty Opening and closing the sign case 1 2 Locate the hex head door screws circled below in each case door At the sign s dedicated circuit breaker turn off power to the sign O La BIND IP IT f COCCO AA PE SEED DoOob5DoDoDoDLoooDbDobobo gt E 2 Lo GIIJJJ ERE SE A EEEESSS Ly 2 iz Pip ulLtu Lv 2b b tuv LP L y ull U C C 9 D O9 C C2 Donbpbonpbpoubpobnbpoonmbm 2 1 E32 t9 2 1 La v D 3 DODD 3 ke Go be be ee DS amp amp OODODUDDO0OODOoo
16. that does not provide an effective ground e Although ground wiring is incorporated with the incoming AC power source the sign still requires an external earth ground attached to the sign s outdoor ground lug e All power wiring must be from circuit breaker protected lines For permanently connected equipment a readily accessible disconnect device shall be incorporated external to the equipment e DO NOT connect the sign to a GFl protected circuit e Atwo pole disconnect device must be installed in the building wiring for each branch circuit supplying the sign e The sign is configured for one of two power configurations only 115VAC single phase or 230VAC single phase power The sign is NOT configured to run off a 208 3 phase power source e The sign must be run on it s own dedicated circuit to ensure proper operation This is particularly important when the sign is installed in a structure containing ballasts for fluorescent lamps They must have their own circuit Not complying with this requirement can lead to intermittent sign operation or malfunction e Do NOT run power to the sign and the ballasts off the same circuit e When ballasts are used in the same vicinity of the Adaptive sign it is recommended that they be of the electronic low harmonic type to further reduce the risk of any interference with the sign e Wire gauge and breakers must be sized or verified in accordance with Adaptive s input power specifications the National Ele
17. the sign F POWER SUPPLY Provides power to all the components in a sign case including display boards Present in all sign cases G JEN Internal mixing fans are used to circulate air inside the sign Present in all sign cases 10 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A Mechanical installation Overview The sign must be installed onto a structure designed to withstand live loads and comply with all national and local codes Live loads include loading from wind and seismic events The method used to install signs varies greatly from location to location therefore it is the installer s responsibility that the installation complies with all national and local codes WARNING Do not open the sign case doors until the sign is fully installed to the sign structure otherwise the sign may tip causing serious injury and or damage the sign Failure to comply will void the sign s warranty Structures defined Sub structure The formed steel angle on the back of the sign top and bottom Factory attached Sign structure Customer or installer supplied structure to which the sign is secured to Sign structures should be approved by a qualified structural engineer as required by local codes ID sign Company name and or logo sign supplied by the customer or installer Sign structure design The design of a sign s support structure depends on a number of factors install methods building
18. the sign to the sign structure PREFERRED METHOD 15 Maximum lifting tilt Lifting bar Lifting bar Lifting strap Ad Ad A ee A d 15 Maximum tilt eed AEE EEES POG COS 08 Figure 14 Lifting the sign 2 Position and secure the sign to the sign structure 3 Remove the sign s lifting eyebolts 22 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A Electrical installation WARNING Hazardous voltage Contact with high voltage may cause death or serious injury Remove power at the source before servicing Failure to properly ground the sign could result in elevated voltage from lightning entering the sign seeking a path to earth High voltage from lightning can result in electric shock fires and destruction of the sign Notice Electrical installation must only be attempted by a qualified electrician Electrical connection must comply with all applicable national and local codes Electrical installation requirements The following electrical installation requirements must be followed or the sign warranty will be voided e The sign must be properly grounded according to the applicable national and local electrical codes for example NEC Article 250 and 600 and IEEE 1100 1999 e DO NOT terminate the ground on metal poles or buildings The metal will corrode resulting in deteriorated grounding properties Additionally metal poles or buildings are often mounted on material
19. to a computer through the connectivity option If applicable do not have the sign connected to a network at this time 2 Atthe computer click the Start button and click Control Panel Internet y My Documents Internet Explorer E mail L3 My Recent Documents Microsoft Outlook iG My Computer E Adobe Illustrator C52 J My Dices Lil Adobe FrameMaker 8 J Control Panel 2 B Click Control Panel 2 Printers and Faxes Adobe Acrobat 8 bids 4 Professional 69 Help and Support amp Adobe Photoshop C52 L q search B VISUAL Mfg 1 7 Bun Microsoft Excel a ECO Database A Click Start All Programs Peso 6 shut oom 2istart O 48 E gt E inbox mi iz Adobe Fra amp 4 Figure 3 Start menu EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 7 APPENDIX IDENTIFY FIND AND CHANGE AN IP ADDRESS 3 Open Network Connections E Control Panel E 3 ziaz Ci QuickTime i Regional and Language Options X Add or Remove Programs Sl Scanners and Cameras de Ey Scheduled Tasks W security Conter senes and Audso Devies Bi Speech SS System nl Tadbar and Start Meris fil ier Accounts divinos Premal Ph wirds Hedas Connect cin Wireless Network Sebup Wizand jme Double click Network Connections Figure 4 Network connections 4 Inthe Network Connections window right click Loca
20. warranty If louvers or air duct covers are used the obstruction free space of the louver air duct cover must be calculated to ensure that it meets the Adaptive requirement For every installation provide adequate ventilation or the sign warranty may be void e DO NOT mount air ducts vents directly to the LED display or its substructure e DO NOT modify the display case or its substructure for ventilation purposes The superstructure design MUST incorporate adequate ventilation e Provide a minimum clearance of one inch above and below the display and six inches behind the display e For EMCs under seven feet in height provide 3 5 square inches of obstruction free ventilation space for every square foot of your display face For EMCs over seven feet high provide seven square inches of ventilation space e Ventilation air ducts MUST be evenly spaced across the top and bottom of the display to help maintain consistent air flow around it e Adaptive recommends that displays installed in a monument structure incorporate outdoor rated fans to draw in cool air through the lower air ducts The sign will cool more efficiently when fans are used to draw in cool air rather than force out hot air EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 13 MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Ventilation requirements chart Ventilation Requirements for EzView Signs up to 7 in H
21. 0 11 11 253 IP address Subnet mask Default gateway Subnet Mask 255 255 0 0 Use the following DNS server addresses Preferred DNS server Alternate DNS server weet C Click OK Figure 50 Internet protocol properties Click OK to close the Local Area Connections Properties window Your computer is now in the same range as the sign s default IP address 10 11 11 254 Go to Installing sign software on page 51 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS SET UP THE SIGN TO COMMUNICATE ON YOUR NETWORK Setting your computer s IP address to communicate with the sign Windows Vista instructions 1 The sign must be powered on and connected to your computer through the connectivity option 2 Atthe computer click Start gt Control Panel gt Network and Internet gt Network and Sharing Center gt Manage network connections 3 In the Network Connections window right click Local Area Connection and choose Properties Note You may be asked for an administrator password contact your network administrator for the password or the prompt Windows needs your permission to continue will appear provide confirmation Se F lm Network Conne x hy Search E Organize SE Views v Dis able this network device Name Status Device Name Connectivity LAN or High Speed Internet 1 As Local Area
22. 09610101 REV A CONNECTING SIGNS CONNECT THE SIGN S CONNECTIVITY OPTION Connect to the sign using the WiFi option If the WiFi units are going to be used on an existing network confirm with your network administrator that the IP addresses listed are available If the WiFi unit IP addresses are already being used you must change the IP addresses before installation see Changing the IP address for an Access Point or Bridge on page 20 for details WiFi units are shipped with the following IP addresses e Access Point transmitter 192 168 1 2 e Bridge unit receiver 192 168 1 1 e Each additional Bridge Starts at 192 168 1 3 and increments by 1 for example 192 168 1 4 192 168 1 5 and so on Note If you would like to set additional security on your WiFi network go to the WiFi setup guide on page 15 gt Connecting to the sign using the WiFi option 1 Route the Bridge WiFi unit s Ethernet cable to the back of the sign bottom right of sign when facing the back of the sign DO NOT mount the Bridge unit until you have completed the Connect to the sign using the fiber optic option on page 41 2 Remove the cover plate and install the strain relief connector Note The cover may already be removed from a previous procedure v A Remove four screws and the cover plate O B Remove one of the 7 8 inch knock outs E for the strain relief connector C Secure the strain relief connector to the c
23. 9 8s 39x 58 58 893 1 3 9 3 3 328 83 83 i 5 m 9m 8989 5 5 9 38 7 5 14 39 34 945 498 5 Ventilation is defined as obstruction free space 14 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Recommended mounting brackets Mounting the Display Method A e Stronger more stable mounting RECOMMENDED e Better suited for cooling requirements for this display Figure 7 Mounting brackets EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 15 MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Wall mounting Displays require obstruction free space for adequate air ventilation between solid mounting surfaces and the top and bottom surfaces DO NOT drill or cut into the LED display case for ventilation purposes Follow mounting instructions and clearance guidelines to ensure adequate ventilation for your display ES SSS SSS SS SS SSS Ss SS SSS ES SSS ESS ESS ESS i SS SSS EES ESSE Vent M 1 d1 1 1 71 E SS a a a a T N A Vent 331 Cooler A air flow Cooler A
24. ECTING SIGNS TEMPERATURE LIGHT SENSOR OPTIONAL Temperature light sensor installation guidelines Choose an installation location that meets the following criteria otherwise the temperature light sensor will not correctly dim the sign or it may record inaccurate temperature readings e Install the sensor below the sign on the sign structure avoiding the intake of hot air emitted from the sign e Air movement is not restricted by nearby walls or other obstructions e Install location background is light colored and not dark colored e Above vegetation and not above asphalt or blacktop e On the north side of a building to provide protection from the sun e Shield the sensor from the effect of the direct sun reflected heat or any nearby sources of heat such as chimneys lamps vents or HVAC ducts e Atleast six feet off the ground and at least one foot below the eave of a protected overhang so convection currents rising hot air flow are not trapped around the sensor Also make sure convection currents are not blocked by mounting plates e Only one sensor is required in a network of signs but it must be connected to the master sign Alternative install location within 25 feet of the master sign Minimum 1 foot clearance below a protected overhang y E building Minimum 6 foot clearance above D Conduit Sign structure the ground Temperature probe Figure 26 Possible install locations fo
25. EW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX IDENTIFY FIND AND CHANGE AN IP ADDRESS 5 Inthe Internet Protocol Version 4 TCP IPv4 Properties dialog select Use the following IP address and enter the following Internet Protocol Version 4 TCP IPvi Properties V General Alternate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings A Click Use the following IP address B Enter the following IP address 10 11 11 253 Subnet Mask 255 255 0 0 Obtain DNS server address automatically 3 Use the following DNS server addresses ure OAS caras I JL SE YE A C Click 0K cancel Figure 10 Internet protocol properties 6 Click OK to close the Local Area Connections Properties window Your computer is now in the same range as the sign s default IP address 10 11 11 254 7 Qoto STEP 3 Installing sign software on page 12 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 11 APPENDIX STEP 3 Installing sign software IDENTIFY FIND AND CHANGE AN IP ADDRESS 1 If using ooh Media 2009 please see ooh Media 2009 sign software on page 51 2 If using ooh Media 3 please see ooh Media 3 sign software on page 54 Configuring t
26. EZVIEW X Modular Case 20mm and 23mm Pitch Signs Sign Installation Manual November 14 2012 Dynamic outdoor advertising solutions Copyright 2012 Adaptive Micro Systems LLC All rights reserved Adaptive Micro Systems 7840 North 86th Street Milwaukee WI 53224 USA 414 357 2020 414 357 2029 fax http www adaptivedisplays com Adaptive is a registered trademark of Adaptive Micro Systems EzView is a trademark of Adaptive Micro Systems All other brand and product names are trademarks or registered trademarks of their respective companies New IP Address Revision history November 14 2012 Initial release 2 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A Table of Contents INTRODUCTION stat Wid WGN Sede ght REN ema EQUIPMENT DESCRIPTION E deco d ees Modular Cases and display boards oooooccccccoocrr Hmmm mmm 7 Top Siae and e Eo OOO dor aca adopte ardor dor def der Deas tuba and aec td aie aes 8 Open MSG CdSe verano EROR ORC Chess Us eee UR ISO 4 dE RR UP d a Re AERE DUET EO oes 9 nis e 10 Case COMPONCHE reza qc DE ODER EHE NOTER Ed chee a hes ys EX EORR dicU orba aede dei sd 10 MECHANICAL INSTALLATION eee ie OO O E e ee ee ee eer S Sl E E 11 suere PEL 11
27. GNS INSTALLING SIGN SOFTWARE Installing sign software EzView X signs will work with ooh Media 2009 or ooh Media 3 If you are using ooh Media 2009 follow the procedure below If you are using ooh Media 3 follow the procedure on page 54 ooh Media 2009 sign software gt Installing the ooh Media 2009 sign software 1 Insert the ooh Media 2009 software CD in the CD ROM drive on the computer 2 On the first screen click the Install ooh Media button Install oohiMadia E Click Install ooh Media View Warranty waa 90h Viedia ooh Media Helo manual Out of Howe Bn s mg Quick Start Guide Software INSTALLATION or UPGRADE Tips and Tricks NOTE If upgrading you will also need ET Brochure to add signs within Ooh Media and then HET upgrade your sign software Install Diagnostics m Eel Install Adobe POF viewer Figure 59 ooh Media 2009 installation window Click No Figure 60 Changing IP address prompt 4 f you would like to install Paint Shop Pro click Yes If you do not want to install Paint Shop Pro click No GE Do you want to install Paint Shop Pro version 8 Paint Shop Pro can be P used to create and modify GIFs Figure 61 Paint Shop Pro install prompt 5 Follow the prompts until you see this one Click Ok Figure 62 Add signs prompt 6 Register your sign software EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A o1 CONNECTING SIGNS
28. IGN INSTALLATION MANUAL PN 1709610101 REV A 37 CONNECTING SIGNS CONNECT THE SIGN S CONNECTIVITY OPTION 3 Route the Ethernet cable through the cover plate and plug it into the sign controller s Ethernet port Plug the Ethernet cable into the sign a controller s Ethernet port LZ b C4 9 Liv m o o VV VN N NY Y Y NY Y y USB port not used Ethernet port connectivity We 200 Box connector sensor n If applicable LVDS cable fy die If applicable temperature light sensor cable Figure 36 Sign controller s Ethernet RJ45 port 4 Secure the cover plate to the junction box being careful not to pinch or crimp the cable D A O 2 ne cave nena A Carefully pull the slack out of the radius is 1 inch O ES cables when placing the cover plate back onto the sign B Secure the cover plate to the sign C Tighten each compression nut until they are snug around the cable NON VV NN NN Y Y Compression nut Figure 37 Securing the cover plate Note Route the cable s downward from the strain relief connector s directing water condensation build up to flow away from the sign s cable entry point 5 Install sign software on the computer that will be used to communicate with the sign refer to Set up the sign to communicate on your network on page 45 38 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 17
29. INSTALLING SIGN SOFTWARE Configuring the ooh Media 2009 sign settings 1 2 3 52 Open the sign software Start All Programs Adaptive Micro Systems ooh Media 2009 ooh Media 2009 M A j S pr Help Manual E P Setup Utility H eohlivledia 2009 Quick Start Guide Th Registration SY Tips and Tricks E Warranty Figure 63 Opening the ooh Media 2009 sign software In the Sign Option Window use the Auto Detect feature to automatically fill in the sign configuration and communication settings Add a New Display Sign Options Sign Communication IP address Host name Service Port Password Set Dimming Options Show display in My Displays list Figure 64 Sign options Ooh Media 2009 will open EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS INSTALLING SIGN SOFTWARE Using ooh Media 2009 to send a test message to the sign 1 Inthe Insert drop down menu select Text Select Insert insert View Language Background Text _ _ Select Text Date Time Temperature RSS Field Symbol Counter Figure 65 Insert new text 2 Anew text message box appears highlight the text inside the message and type an appropriate test message Figure 66 New text window 3 Extend the length of the message by stretching it
30. ITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A EQUIPMENT DESCRIPTION SIGN INTERIOR Sign interior Case components Front inside view All sign cases contain a power supply and fan 5 ae sign case components inside view of the controller case Description AAA computer used to control the sign In master slave configurations the slave sign has a LVDS repeater CONTROLLER in this location instead of an internal computer Used to bring in sign communication cables such as Ethernet temperature lightsensor optional and master COMMUNICATION slave optional cabling The junction box has two cover plates allowing access to the communication JUNCTION BOX re connections from the inside or the outside of the sign The sign s power entry terminal is located inside this junction box The junction box has two cover plates POWER JUNCTION BOX _ 0 allowing access to the sign s main power terminal from the inside or the outside of the sign PoE INJ ECTOR El T T LOCATION INSIDE OF Only applicable with the WiFi connectivity option The PoE Power over Ethernet device is supplied with the SIGN WiF i Fiber Connectivity options and this location inside the sign is reserved for the PoE devices installation POWER DISTRIBUTION Used to route power from row to row and from power supply to power supply in each row Only present in the TERMINAL left most column of the sign when facing the front of
31. ITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 7 EQUIPMENT DESCRIPTION SIGN EXTERIOR Top side and rear views Figure 2 External views of a sign with multiple case s other sizes are similar em me O QAI SIGN SUB STRUCTURE The 2 x 3 x 0 14 steel angle along the back of the sign top and bottom is used to install the sign Each sign case contains electronic equipment used to display messages on the display boards SIGN CASE l Never drill or cut into the sign case for any reason or the sign warranty will be void Used to lift the sign into position Remove after the sign has been installed D LED DISPLAY BOARDS Used to display messages Also referred to as driver boards When facing the front of the sign the controller case is always the bottom left most case of the sign In master CONTROLLER CASE slave sign configurations the master sign has a controller and the slave sign has a LVDS repeater Used to connect to an earth ground rod Signs must be grounded per NEC 250 and local electrical codes See GROUND LUG Earth ground the sign on page 26 for details Note Never use the sign s ground lug to ground welding or any other installation equipment or the sign warranty will be void COMMUNICATION Route Ethernet communications temperature light sensor optional and master slave optional cabling into JUNCTION BOX one of the three 7 8 inch conduit holes The cable entry point into the
32. Key 2 mms Only use letters A F NB and numbers 0 9 for Encryption Key values Encryption Key 4 E begel Figure 32 Wireless WEP key setup window Although you can leave the WEP Key Encryption value at the default settings doing so would leave the sign and network susceptible to eavesdropping and hacking Consult the 11g Wireless Outdoor Client Bridge AP User s Manual or your networking professional for more information e For Key Length select 128 bit e Set the Key Encryption to the same settings you used for the Access Point see 26 character encryption key on page 17 4 Click Apply Changes 5 Click Close 6 Onthe Wireless Security Setup screen click Apply Changes Install additional Bridge units For point to multi point installations use the IP address labeled on the additional Bridge unit and repeat the Configure the Bridge on page 18 procedure EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 19 APPENDIX CHANGING THE IP ADDRESS FOR AN ACCESS POINT OR BRIDGE Changing the IP address for an Access Point or Bridge 20 If your network configuration requires the Access Point and Bridge units to have different IP addresses you can do so at any time by following these instructions Avoid IP address conflicts disconnect the device with the conflicting IP address from the am computer before connecting the Access Point or Bridge unit or use a different comput
33. PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS Set up the sign to communicat SET UP THE SIGN TO COMMUNICATE ON YOUR NETWORK e on your network Regardless of how the sign will be connected to your network or computer it must have an IP address in the same range as your computer or network The IP address of each sign is set in the factory to 10 11 11 254 This is the default IP address the address will appear on the sign display when first starting the sign security cameras go to Identify fi If your computer will only be used to operate the sign continue with one of the following e Setting your computer s IP address to communicate with the sign Windows XP instructions on page 45 e Setting your computer s IP address to communicate with the sign Windows Vista instructions on page 47 Setting your computer s IP address to communicate with the sign Windows XP instructions 1 The sign must be powered on and connected to your computer through the connectivity option 2 Atthe computer click the Start button If your computer is connected to multiple devices for example a router or switch printers or nd and change an IP address on page 7 and click Control Panel Internet 4 My Documents Internet Explorer ea 7 4 My Recent Documents I Microsoft Outlook q Mr Computer E Adobe Illustrator C52 ty my Pistes z Network i romance e Control Panel B Click Control
34. Panel S a Adobe Photoshop C52 25 VISUAL Mfg x Microsoft Excel ECO Database All Programs A Click Start Esat 23 E gt Figure 46 Start menu 3 Open Network Connections Ini xj Fle Edt view Faves Tools Help E G h jo rad e ah XM IC O SIBE Double click Network Connections Accescblity Options E Add Hardware 1 Judd or Remove Programs y Administrative Tools 13 Printers and Faxes 9 Help and Support y Search 7 7 Bun FA Log oft 0 soon S Ci Quick Tere A hegora and Language Options sh Scanners and Cameras Scheduled Tasks e Security Conder I scores and Audio Devices Time Bf Speech 30 System nl Tadbar and Start Meri BE er Accounts dg wredows Prenal P Windows Media Connect phir A Wireless Hebwork Sebup Wizaid By Power Options Printers and Panes 535 objects Figure 47 Network connections Network Connections he Phone and Modem Opbons I Portable Mecha Devices EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 45 CONNECTING SIGNS SET UP THE SIGN TO COMMUNICATE ON YOUR NETWORK 46 4 In the Network Connections window right click Local Area Connection and choose Properties Network Connections File Edit View Favorites Tools Advanced Help J P 2 Search lig Folders Address e Network Connections LAN or High Speed Internet A Right click Local Area
35. Properly grounding each sign is necessary because it is an essential means of preventing shock shock hazards potential fire hazards and damage to low voltage components Lightning strike protection Though surge protection is incorporated into a sign to protect a sign from high voltage lightning transients additional surge protectors such as an external earth ground need to be installed in accordance with NEC Articles 280 and 285 and local electrical codes A sign bonded to an earth ground has a means of dissipating the high voltage and current from a lightning strike The resistance of the grounding electrode must be as low as possible However damage can still occur to a sign s electronic equipment from lightning voltage transients 24 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A ELECTRICAL INSTALLATION CONNECT POWER TO THE SIGN Connect power to the sign WARNING Hazardous voltage Contact with high voltage may cause death or serious injury Remove power at the source before servicing Connecting power to the sign 1 Run AC power wiring to the back of the sign in weather proof conduit Route the AC power conduit to the back of the sign bottom right most case when facing the back of the sign Ground lug connect to an earth ground rod Power junction box Figure 16 Running power to the sign 2 Connect AC power wiring to the sign s power entry terminal al A Remove
36. UAL PN 1709610101 REV A Appendix Technical specifications Sign label Sign labels are located on the outside near the power junction box Adaptive Micro Systems LLC Ada ptive 7840 N 86th Street Milwaukee WI 53224 USA EZVIEWX A SIGN MODEL 30000000000000000000000 ARE 00 0 000 008400 OUUU UNUDUN AD B S N HNXXXXXXXXXX l tHEXXKXXIXXXXXX VOLTS RKXXXXXXXV FREQUENCY 50 60 Hz AMPS XXAXXAXAAA L Figure 1 Sample sign labels for a 20mm 32x96 pixel sign C ZV 20 RGB 032RX096C MC 115 L Voltage 115VAC Case design MC z Modular case SC Single case extruded Display area Rows and columns in pixels MODEL NUMBER Sign color configuration RGB Full color RED Red AMB Amber LED pitch distance between any two adjacent pixels 20 20mm 23 223mm ZV EzView PARTS SERVICEABLE BY TRAINED TECHNICIANS ONLY DISCONNECT POWER BEFORE SERVICING sone maHa EN SERIAL NUMBER Consecutive unique identification number ELECTRICAL INFORMATION Input voltage frequency and amperage EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 5 APPENDIX TECHNICAL SPECIFICATIONS Display Board DIP switch settings If a display board on the sign is displaying incorrect information the DIP switch settings on the board maybe incorrectly set The following chart is also located inside the sign controller case when facing th
37. able to the slave sign s communication junction box and remove the enclosure nut Remove the enclosure nut Do not remove the rubber from the LVDS cable Ls enclosure gasket Figure 21 Strain relief connector s enclosure nut 28 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS CONNECT A MASTER AND SLAVE SIGN OPTIONAL 4 Install a strain relief connector on the slave sign s cover plate A Remove four screws and the cover plate SOL B Remove one of the 7 8 inch knock outs for the strain relief connector a 4L Do not tighten assembly Loosen the compression nut using the compression nut to adjust the cable length Figure 22 Strain relief connector installation 5 Plug the LVDS cable into the slave sign s LVDS repeater Plug the LVDS cable into the sign s LVDS repeater VV VV NY Y Y Y Y Y LVDS cable Figure 23 LVDS cable connection at the slave sign 6 Secure the slave sign s cover plate to the sign being careful not to pinch or crimp any cables OO 9 O Minimum LVDS cable 7 bend radius is 1 inch _ m A Carefully pull the slack out of the e cable when placing the cover plate back onto the sign D ARH B Secure the cover plate to the sign AY C Tighten the compression nut until it is snug around the cable VV VV NN N Y YN Compression nut Figure 24 Securing the cover plate Note Route the cable s
38. age to the sign Figure 79 Send message icon 7 Verify the message appears on the sign 96 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS INSTALLING SIGN SOFTWARE Using ooh Media 3 to manually add a display ooh Media 3 typically detects a display with the latest firmware when you connect it to a computer or network If it doesn t or if you have a display with older firmware follow these instructions to add it 1 In the upper left of the ooh Media window click Schedule amp ooh Media File Edit Insert 22048 19 e Frame Sequence New Open i Text save z1 RP ad Background Edit Display Query Display Delete Display Send Schedule Ctri U Get Schedule Ctrl D Sign Configuration Sign Communication Hame EM IP sddress Host name 10 11 11 254 Model Service Port a Size in Pixels Height vit Password E____ Color Auto Detect Dimming Opbors Time Zone Unknown Change Date and Time Change Time Zone E Show display in My Displays lest Figure 80 0oh Media 3 Sign Options dialog box 3 Fillin the Sign Configuration information e Enter a unique Name for your display If you have multiple displays it may be helpful to use a title that includes the size or location e Select the display Model from the drop down list e Enter the Height and Width of th
39. art of the sign except for the sign s sub structure Drill holes at the center of the sign s sub structure width Drill holes 1 2 or less D f V V V DO NOT Drill holes closer than 1 to the sign s sub structure edges Drill holes greater than 1 2 Notch the sign s sub structure Drill holes into the side top bottom or front of the sign Figure 13 Drilling guidelines Notice Dissimilar metals must be isolated to avoid galvanic corrosion Any area on the sign from which paint is removed during installation must be recoated with paint that is UL recognized to standard UL 1332 category DTOV2 Failure to repaint the area will result in accelerated corrosion of the sign Adaptive Micro Systems is not responsible for any failure in the sign s structure because of accelerated corrosion Failure to comply will void the sign s warranty EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 21 MECHANICAL INSTALLATION INSTALL THE SIGN TO THE SIGN STRUCTURE Installing the sign to the sign structure WARNING Crush hazard Improperly lifting of a sign can create a crush hazard causing personal injury and damage the sign Only use the sign s lifting eyebolts to lift the sign Lift the sign evenly and level with no more than a 15 degree tilt 1 Use a lifting bar adjusted to the width of the sign s lifting hardware lift
40. bDoobDoot oboobDoobDoobpoopbpbo Ui La hip LA S 2012 iP Phe tL 3 iP E UL E 5 DO Oooo SOOO OOOOOOOD I PEIPER DO D C C amp 5 C D 2C C2 C2 2 C C2 2 C2 C2 2 D OD ODPDODUDDDDoDDoDOopooDbDDOoODDobooDoooDoobDboobbo OUDDODDDODOoDoobDoobOoODoOoODooooo0DoobDbto AAA KE v bb PH Dt Duabppob poubpppubmn C t5 e OOo 12 5 DOD OO OPOPMOMDODMDOOD ODODOoODDoouDbDoobDoobDoUotoDUDoounDbDobopbooobpoobbo DUDDDDUDDDDDDDDDDOoODOoDDoDDoobDDobopbDoobobopo PDOPODOPODODDOD GoOobDoOooOoDoOoDoDoOooDoobooDo OUDDDDDDDDobobpboopbpo D D to tb Lo tb bb OD gt Oooo bt PO bob bo ODobDoopDoobpDooboo ff opDoo5DoobDooboooouo AAA AA There is one hex head door screw in each display board e 1x3 cases have three hex head door screws 1x4 cases have four hex head door screws Figure 3 Door screws are located in the top center of each display board 1x3 case shown 3 Use a 5 32 inch hex tool to release each hex head door screw Turn the screws counter clockwise until they release from the case open the door by pulling it toward you Open the door slowly to prevent damage to internal components 5 32 inch hex tool on 6811 7076 Figure 4 Opening the sign case door 4 To close the case evenly push the door close and secure it to the sign case by turning each hex head screw clockwise 5 Atthe sign s dedicated circuit breaker turn on power to the sign EZViEW X MODULAR CASE 20MM AND 23MM P
41. codes foundation sign dimensions sign weight wind loading and seismic loading If required by local codes sign structure designs sign installations and connections should be approved by a qualified structural engineer Call Adaptive Micro Systems at 1 800 558 7022 for contact information on structural engineering consultants EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 11 MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Sign installation guidelines and requirements Notice Do not use sign s ground lugs for grounding installation equipment such as welding equipment or the sign warranty will be void Only the sign s sub structure may be welded Welding any other part of the sign will void the warranty Sign installers must comply with the following Adaptive requirements or the sign warranty will be void e Any ID sign fascia trim or structure above the sign must either have flashing installed or it must extend past the face of the sign e DO NOT allow water from the above ID sign fascia trim flashing or any other structure to drip directly onto the sign s door seams e DO NOT seal the sign in a structure enclosure that restricts hot air from escaping around the sign e DO NOT drill or cut into the sign case however it is okay to drill into the sign s sub structure e Comply with all sign ventilation and clearance requirements refer to Ventilation requi
42. col that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or no connectivity Figure 25 Local Area Connection Properties window In the Internet Protocol TCP IP Properties dialog select Use the following IP address and enter the following Internet Protocol TCP IP Properties nm General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 10 Subnet mask IP address 192 168 1 10 Subnet Mask 255 255 255 0 Use the following DNS server addresses Preferred DNS server Alternate DNS server EEG NN Figure 26 TCP IP properties window 5 Click OK 6 In the Local Area Connection Properties dialog click OK EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX WIFI SETUP GUIDE Configure security for the Access Point 1 Click Wireless and then click Security 2 For Encryption select WEP Wireless Security Setup This page allows you setup the wireless security Turn on WEP or WPA by using Encryption Keys could prevent any unauthorized access to your wireless network Set WEP Key WEP 64bits WEP 128bit
43. computer with the Ethernet option Rear view of sign Building wall ZI Computer running sign software Ethernet CAT5 300 foot maximum length Network router A Ethernet cable must either be outdoor rated or Ethernet CAT5 cable routed through weather tight conduit 300 foot maximum length Figure 31 Overview of connecting a sign to an Ethernet network with the Ethernet option 34 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS CONNECTIVITY OPTION OVERVIEW WiFi wireless option WiFi units are used to create a wireless bridge between your network or computer and the sign The Access Point is used to transmit information to the sign from the computer The Bridge is connected to the sign and receives information sent from the Access Point AP Both WiFi units receive power through a PoE Power over Ethernet injector Note If applicable connect the AP s PoE into your network router instead of directly into a computer Access point AP Obstruction free line of sight Rear view of sign Building rooftop DA Computer mmm running sign L software NI Ethernet CAT5 cable PoE injector Power over Ethernet VAZZZZZZZZL Ethernet CAT5 cable Building wall 300 foot maximum length Figure 32 Overview of connecting a sign with the wireless WiFi option Computer running sign software
44. ctric Code and applicable local codes Under sizing the wire gauge or breaker size can lead to intermittent sign operation or malfunction e Use minimum 80 C copper wire only e DO NOT route power or communication wires out of the case door and around the side of the sign the wires will be damaged when the door is closed EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 23 ELECTRICAL INSTALLATION ELECTRICAL INSTALLATION REQUIREMENTS Conduit use e DONOT drill additional conduit holes in the sign e All electrical conduit connections must be watertight e DO NOT route communication wiring in close proximity or parallel with power wiring power conduit or high voltage wiring e Separate conduits must be used for communication wires for example Ethernet and for power wires Y Communications Conduit V Y Power Conduit V Power conduit OKOL Figure 15 Correct and incorrect power and communication conduit use Adaptive Explains Is it necessary to run two conduits to a sign If power and communication wires are put in the same conduit there is a chance the communication wires might pick up electrical interference from the power wires For example when a live power cord is placed next to a stereo speaker wire the interference from this cord may cause the speaker to hum In the case of a sign this same effect could disrupt messages sent to the display Earth grounding signs
45. d follow STEP 2 Setting your computer s IP address to communicate with the sign on page 7 but use the original settings or choose Obtain IP address automatically if your network is DHCP enabled EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 13 APPENDIX IDENTIFY FIND AND CHANGE AN IP ADDRESS gt STEP 5 Sending a test message to the sign 1 Open the sign software 2 Inthe Insert drop down menu select Text Select Insert Insert View Language Background Text Select Text Date Time Temperature R55 Field Symbol Counter Figure 17 Insert new text 3 Anew text message box appears highlight the text inside the message and type an appropriate test message Figure 18 New text window 4 Extend the length of the message by stretching it in the Timeline see figure below Extend the message long enough for you to go to the sign and look at it Time in seconds Figure 19 Message length 5 Click the disk icon to save the message 6 Name the message and click Save Figure 20 Saving the test message 7 Click the send message icon to send the message to the sign Figure 21 Send message icon 8 Verify the message appears on the sign 14 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX WIFI SETUP GUIDE WIFI
46. d out Request timed out Request timed out Ping statistics for 192 168 1 231 ackets Sent 4 Received Lost 4 106 loss N Figure 37 Unsuccessful ping screen 22 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A
47. e mounting 4 brackets Vent Cooler AN k gt Cooler air flow air flow Superstructure mounting 4 Vent brackets Clearance requirements Minimum Clearance 1 inch Minimum Clearance 6 inches Minimum Clearance 1 inch Figure 10 Side view of two signs installed in a monument Forced Convection RECOMMENDED FOR HIGH TEMPERATURE ENVIRONMENTS ID Sign TP LE TI the backs of the sign cases e Cooler A air flow Vent Hot air flow MN QS Install fans to pull cooler air into monument cavity Direct the fans toward NL E cooler AP airflow A Vent FAILURE TO FOLLOW THESE GUIDELINES MAY VOID WARRANTY DO NOT allow water from aove ID sign fascia trim nstall flashing onto the structure DO NOT seal off air f ua SF NOT mount sign directly on the base floor EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Monument installation view from the front Hot air flow Hot air flow Provisions for adequate air circulation and ventilation especially the ability of hot air to rise and escape from the unit must be incorporated into the design of the sign structure DO NOT drill or cut into the LED display case for ventilation purposes DO NOT rely on side vents to cool the unit Top and bottom vents must be included for adequate air circulation Installa
48. e display in pixels EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 57 CONNECTING SIGNS INSTALLING SIGN SOFTWARE 4 Update the Time Options Note These settings require the Sign Communication settings to be valid e Click Change Date and Time The Change Date and Time dialog opens Signl Change Date and Time x A 8 Synchronize with the PC _ Set to HH MM SS MM DDPPner e If the display is to have the same time as the controlling PC select Synchronize with the PC e Ifthe display is to have a different time than the controlling PC select Set to and fill in the time and date information e Ifthe display is in a different time zone click Change TimeZone select the appropriate TimeZone from the list and click Ok For details see Change Time Zone Options in the ooh Media User Manual Default Display 144 x 432 Change Time Zone Options x Time Zone Opbons XUTC 06 00 Central Time US 4 Canada 4 Automatically Adjust the Clock of the Display for Daylight Savings Time Changes 5 Inthe Sign Communication area do the following e Click Auto Detect e f ooh Media is unable to automatically detect your display update the IP address Host name Service Port and Password fields 6 If desired check the Show display in My Displays list box 7 Click Ok 98 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MAN
49. e sign it is the bottom left most case Checking the Display Board DIP switch settings 1 Open the case door that the problem display board is located in Refer to Open the sign case on page 9 for details Verify the DIP switch settings on the problem display board are correctly set based on the board s position on the sign If necessary change the DIP switch settings or you may have to replace the display board DIP switch settings for 16x16 display boards DIP switch settings do not change regardless of the sign size SIGN COLUMN E in e 112 176 16 25 26 2 56 27 2 5 7 20 7 2 5 6 7 28 2 5 8 2 6 8 2 5 6 8 R1 C1 R1 C2 R1 C3 R1 C4 R1 C5 R1 C6 R1 C7 R1 C8 R1 C9 R1 C10 R1 C11 32 36 35 6 37 3 5 7 36 7 35 6 7 38 358 3 6 8 3 5 6 8 SIGN ROW R R2 C1 R2 C2 R2 C3 R2 C4 R2 C5 R2 C6 R2 C7 R2 C8 R2 C9 R2 C10 R2 C11 in pixels 2 3 5 2 3 5 48 239 236 2 3 5 6 2 3 7 2 3 5 7 2 3 6 7 2 3 8 2 3 5 8 2 3 6 8 68 R3 C1 R3 C2 R3 C3 R3 C4 R3 C5 R3 C6 e a R3 C8 R3 C9 R3 C10 R3 C11 64 45 46 456 47 457 467 45 6 7 48 45 8 46 8 4 5 6 8 R4 C1 R4 C2 R4 C3 R4 C4 R4 C5 R4 C6 R4 C7 R4 C8 R4 C9 R4 C10 R4 C10 TOP Master sign shown for Slave signs all display boards will also have DIP switch 1 ON DIP switches ee l DIP switch UP number side is OFF T NO DIP switch DOWN is ON ont
50. ed by others Customer supplied weatherproof pathway conduit or innerduct Figure 34 Overview of connecting a sign with the fiber optic network option 36 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS CONNECT THE SIGN S CONNECTIVITY OPTION Connect the sign s connectivity option Depending on the sign s connectivity option follow one of the procedures e Connect to the sign using the Ethernet option on page 37 e Connect to the sign using the WiFi option on page 39 e Connect to the sign using the fiber optic option on page 41 Connect to the sign using the Ethernet option gt Connecting to the sign using the Ethernet option 1 Route the Ethernet cable from the computer network to the back of the sign bottom right of the sign when facing the back of the sign 2 Remove the cover plate and install the strain relief connector or weather tight conduit Note The cover may already be removed from a previous procedure A Remove four screws and the cover plate for the strain relief connector C Secure the strain relief connector to the cover plate This side of the assembly faces away from the sign Do not tighten assembly SF X n S Sf s g ty using the compression nut e N ND GO CS Re QU S e Q CP a O e NY Qe D o Figure 35 Communication junction box location EZViEW X MODULAR CASE 20MM AND 23MM PITCH S
51. ee the option to create a new message as shown in Figure 74 Create a new message using ooh Media 3 If you do not see this option please see Using ooh Media 3 to manually add a display on page 57 to manually add a display using ooh Media 3 File Name New Message 1 Sign NEW Excite 1 mn Color base RGB Figure 74 Create a new message using ooh Media 3 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 55 CONNECTING SIGNS INSTALLING SIGN SOFTWARE Using ooh Media 3 to send a test message to the sign 1 Inthe Insert drop down menu select Text Select Insert J Insert View Language Background Text Select Text Date Time Temperature RSS Field Symbol Counter Figure 75 Insert new text 2 Anew text message box appears highlight the text inside the message and type an appropriate test message Figure 76 New text window 3 Extend the length of the message by stretching it in the Timeline see figure below Extend the message long enough for you to go to the sign and look at it Time in seconds Figure 77 Message length 4 Click the disk icon to save the message 5 Name the message and click Save L My Documents ys My Computer My Nenad Pisces Figure 78 Saving the test message 6 Click the send message icon to send the mess
52. eight Use 3 5 square inches of ventilation for every 1 square foot of the display face 7 square inches is equivalent to a 3 air duct Total Case Height Case Width Case Case Ventilation Inches Inches Sq Inches Sq Feet Required Sq Inches Inlet Outlet Ventilation Ventilation Sq Inches Sq Inches Columns EzView 20mm Displays 5 9 s e so s s s s 39 3 1 8 1 58 3 8 38 u IE E 3 m 3 e me 99 28 va B9 39 8 1 89 9 5 35 B58 B5 x e 52 ss 951 12 es Bb Bb 35 o8 9 n a nu 15 58 2329 29 a 134 ss 39 ss es 7 an X8 Om 385 OI sma m 88 42 453 II 7 33 8 3m 3s X8 3 3 au o oum p ome p ome owes oso RO 160 17623 31 115 76 57 88 57 88 EzView 23mm Displays nL E Lx qos T ow ss wwe ur 7 88 71 34 34 ju Ms 134 1805 Bl ee 238 23 18 7 485 3 3 941 Hs 3 589 55 me ms m ama dl s 280 280 s p poe 0 5 IE 57 L3 SI IS E II a a 8 L5 14 me m ux 149 559 3 3 s w 3 5 SG a E Lian LS Rss ses Lis Ca 95 9 3 333 38 59 99 5 i5 85 um 3 3 328 83 8 8 18 8s 143 9
53. er to change the IP addresses with gt To change the IP address for an Access Point or Bridge 1 4 5 6 Ls Make sure your computer is using an IP address within the 192 168 1 X range See Change the IP address on the computer on page 15 At the computer open a web browser and type the IP address of the unit and press the ENTER key e Fora Bridge type 192 168 1 231 or the IP address labeled on the Bridge e Fora Access Point type 192 168 1 232 At the login prompt type admin for the Username and admin for the Password and click OK Connect to 192 168 1 1 Figure 33 Access Point or Bridge unit login prompt In the left menu area click TCP IP Settings and then click LAN Interface Click in the IP address field and type in the IP address to use for the unit LAN Interface Setup This page is used to configure the parameters for local area network which connects to the LAN port of your Access Point Here you may change the setting for IP addresss subnet mask DHCP etc IP Address 192 168 1 2 Subnet Mask 2552562580 Default Gateway 0 0 0 0 DHCP Disabled v DHCP Client Range r Figure 34 LAN interface setup screen Click Apply Changes Click OK EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX TROUBLESHOOTING SIGN CONNECTIVITY Troubleshooting sign connectivity If nothing appears on the sign when you send messages from the sig
54. four screws and the cover plate C C C B Remove one of the 7 8 inch knock outs for the AC power conduit a 9 O C Strip 3 8 inch of insulation off of the incoming AC power wiring D Connect AC wiring according to the wiring label press the button on top of the terminal block and fully insert the power wire NEUTRAL PART NO 1704600201 REV A E Secure the cover plate back onto the sign be careful not to pinch any of the power wires Figure 17 AC power wiring connections The AC power conduit connection to the sign s power junction box must have a water tight seal EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 25 ELECTRICAL INSTALLATION EARTH GROUND THE SIGN Earth ground the sign Contact a qualified electrician if you have any questions regarding earth grounding the sign Adaptive recommends the following Use copper clad ground rods as the grounding electrode Copper clad provides effective grounding for an indefinite period of time e Depending on the local soil conditions and local codes more than one ground rod may need to be installed e Since moisture becomes more stable at greater distances below the earth s surface when possible install the ground rod so that it extends below the frost line to lessen the deviation in the system s resistance gt Earth grounding the sign 1 Connect a 6AWG gauge ground wire grounding conductor to the sign
55. he sign s door seams install flashing to the structure Provide a minimum clearance of 1 inch above and below the sign and 6 inches behind the sign DO NOT allow water from the above ID sign fascia trim or flashing to drip directly onto the LED display s door seams Air Duct Ventilation installation for pole mounted signs Provide 3 5 square inches of ventilation obstruction free space for every 1 square foot of sign per face Consult the Ventilation Requirements Table Ventilation air ducts MUST be installed across the top and bottom of the sign at evenly spaced intervals e Evenly spaced vents help maintain a consistent air flow around the sign Use 7 square inches if sign height exceeds 7 feet 20 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A MECHANICAL INSTALLATION INSTALL THE SIGN TO THE SIGN STRUCTURE Install the sign to the sign structure The methods used to install a sign to a sign structure vary greatly It is the installers responsibility to ensure that the installation complies with all national and local codes When drilling holes or welding the sign s sub structure follow these guidelines or the warranty will be void e DONOT drill or cut into the sign case Drill holes as needed in the sign s sub structure for fasteners e DO NOT use the sign s ground lugs for grounding installation equipment such as welding equipment e DO NOT weld any p
56. he sign settings 1 Open the sign software ooh Media 2009 Start All Programs Adaptive Micro Systems gt ooh Media 2009 gt ooh Media 2009 dH TH Help Manual E P Setup Utility agh Media 2009 Quick Start Guide ps Registration Tips and Tricks 4 Warranty Figure 11 Opening sign software 2 Sign software screen will open click Schedule ooh Media 2009 File Sign Language 1 Sign Management Select a sig Message CE Excite 1E Graphic AS A Tools Legend L unknown edie Detete aca Figure 12 Schedule window Click Schedule ooh Media 2003 Start gt All Programs gt Adaptive Micro Systems gt ooh Media 3 gt ooh Media lt T Help Manual E P Setup Utility 9 KwikTrigger Reference Ya jger amp ooh Media 3 T Quick Start Guide Registration t Tips and Tricks T Warranty Schedule Transmission Legend BE unknewn 3 Select your sign from the list and click the Commands button EI oohiMedia 2009 CE Sign Management Select your sign Graphic PO Tols A a Edit Delete Add unknown Figure 13 Sign selection ooh Media 2009 Fille Sign Language Tools se LE Excite 15248 RGB 16 48 10 11 11 254 Es progress Es success Commpnds Get Schedule Send Schedule Cat Click the Commands button 12 EZVIEW X MODULAR CASE 20MM
57. ial finish for your fiber optic mounting application enclosure Remove the four rubber plugs from the cover of the fiber enclosure and place them over the mounting hardware F Pullthe fiber optic cabling through the weatherproof pathway G Route the fiber optic cabling through the water tight box connector and secure the weatherproof pathway to the connector Fiber converter Transmit Receive ST fiber optic Receive Transmit Fiber converter H Plug the ST fiber ends into both fiber converters The ST fiber ends plug into opposite ports on the two fiber converters shown in diagram Figure 42 Installing the fiber optic enclosure 42 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS CONNECT THE SIGN S CONNECTIVITY OPTION 3 Route the Ethernet cable from the Fiber Optic Option Box to the back of the sign to the back of the sign bottom right of the sign when facing the back of the sign 4 Remove the cover plate and install the strain relief connector or weather tight conduit Note The cover may already be removed from a previous procedure AY a O A Remove four screws and the cover plate for the strain relief connector C Secure the strain relief connector to the cover plate This side of the assembly faces away from the sign SS O O Do not tighten assembly es Y Gg x SS L 4 using the compression nut
58. igned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings A Click Use the following IP address B Enter the following IP address 10 11 11 253 Subnet Mask 255 255 0 0 Obtain DNS server address automatically 3 Use the following DNS server addresses ure OAS caras I JL SE YE A C Click 0K Cancel Figure 53 Internet protocol properties 6 Click OK to close the Local Area Connections Properties window Your computer is now in the same range as the sign s default IP address 10 11 11 254 7 Go to Installing sign software on page 51 48 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS SET UP THE SIGN TO COMMUNICATE ON YOUR NETWORK Conduct a site survey It is recommended to use two or three people and provide a way for them to communicate while conducting the site survey gt Conducting a site survey Power must be supplied to the sign in order to conduct a site survey with the WiFi network 1 Plug the cable from the wireless unit labeled Access Point into the AP Bridge port of the PoE injector NOTE This is a generic view of a PoE injector Please follow the instructions supplied by the manufacturer of the PoE for connecting the Power Network and AP Bridge to the appropriate connection points gj P BRIDGE O NETWORK GROUND
59. igure security for the Bridge The Bridge and Access Point values must be the same or they will not communicate with each other If you skipped this step for the Access Point then you should skip this step for the Bridge 1 Click Wireless and then click Security 2 For Encryption select WEP Jj wireless Client Bridge SETUP MONU Microsoft Internet Explorer Fie Ede View Favorited Took Heb Adress iif bitte 192 068 L L home ase a A 4 EM Toy E ES Wireless LAN Client Bridge na l Management Wireless Security Setup MORIE sens This page alawe yoi eitig tha wirslaze ceci Tum on WEF or WPA by uing Beenie Keyt SAMP Settings cod previsi any nante acera do your wields atliek WA C THE AES WRAL Cipker Suite THIF AEE I ve Shared Key Format Pre Shared Key Mone Esa exception EF ji stead pots ral oer MEF kay value J Reser Figure 31 Wireless security setup window 18 EzViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX WIFI SETUP GUIDE 3 Click the Set WEP Key button The Wireless WEP Key Setup screen opens 3 hittpzif 192 169 1 1 REF Key Setup Microsolt Inlernel Explorer Wireless WEP Key Setup This page allows you setup the WEP key value You could choose use EL bit os 122 bit as ihe ari ryplum key ard aset AG ir lez ace Ube Formal ol equi wahis eu a Key Lengih Key Format De Gamld Tx Fury Encryption Kry l Encryption
60. in the Timeline see figure below Extend the message long enough for you to go to the sign and look at it Time in seconds Figure 67 Message length 4 Click the disk icon to save the message 5 Name the message and click Save L My Documents 3 My Computer My Nenad Pisces Figure 68 Saving the test message 6 Click the send message icon to send the message to the sign Figure 69 Send message icon 7 Verify the message appears on the sign EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 53 CONNECTING SIGNS INSTALLING SIGN SOFTWARE ooh Media 3 sign software 3 Installing the ooh Media 3 sign software 1 Make sure your sign is properly connected to the local area network and is turned on before installing the software The sign must be connected and turned on for ooh Media to automatically detect the display 2 Insert the ooh Media 3 software CD in the CD ROM drive on the computer 3 On the first screen click the Install ooh Media button ADAPTIMI Install oohiMeds E Click Install ooh Media View Warranty Upgrade LED Display oohiMeda Help Tips and Tricks om Home Ml Adve i ing E E Trar Brochure E Install Diagnostics metal Adobe Figure 70 o0oh Media 3 installation window 4 Follow the prompts until you see this one 57 Setup ooh Media 3 Select Components Which components should be installed Select the compo
61. l Area Connection and choose Properties Network Connections File Edit View Favorites Tools Advanced Help gt 27 Search gt Folders a Address e Network Connections LAN or High Speed Internet A Right click Local Area Connection L _ nd Repair Wizard Bridge Connections Sl Create Shortcut New Rename puras B Select Properties Figure 5 Local area connection 5 Select Internet Protocol TCP IP and click the Properties button 4 Local Area Connection Properties General Authentication Advanced Connect using E9 Intel R PRO 1000 MT Network Con This connection uses the following items ied Client for Microsoft Networks ra a File and Printer Sharing for Microsoft Networks M E QoS Packet Scheduler riemet Protocol TCP Y A Select Internet Protocol TCP IP os ote B Click Properties button Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or no connectivity Figure 6 Local area connection properties 8 EzViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX 6 IDENTIFY FIND AND CHANGE AN IP ADDRESS In the Internet Protoc
62. n software the first step is to verify there is communication with the sign You can do this by pinging the sign Ping is a tool used on computer networks to test whether devices are reachable The goal of pinging a device is to get a reply If there is no reply the ping request times out meaning the device is unreachable See To ping the sign Bridge or Access Point on page 22 for instructions If you can successfully ping the sign then the WiFi devices are communicating properly Basic troubleshooting sequence Ping the sign Is there a reply Yes Contact Technical Support No Ping the Access Point There may be a problem with the Access Point s IP address the wireless unit itself orthe internal No network Refer to the manual forthe WiFi device contact your network technician or contact Technical Support Is there a reply Yes Y Ping the Bridge There may be a problem with the Bridge s IP address orthe cabling See your network technician or contact Technical Support Is there a reply iis v Yes Y Try resending the message If the problem continues contact Technical Support EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 21 APPENDIX TROUBLESHOOTING SIGN CONNECTIVITY gt To ping the sign Bridge or Access Point 1 The pi
63. nents you want to install dear the components you do not want to install Click Next when you are ready to continue Core Files Media Library Jasc Paint Shop Pro Current selection requires at least 404 8 MB of disk space Figure 71 Select ooh Media 3 components to install 5 Click the box to place a check mark next to each component you wish to install To deselect a component click to remove the check mark from the box 6 Click Next to continue the installation 94 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS INSTALLING SIGN SOFTWARE 7 Follow the prompts until you see this one ooh Media 3 Completing the ooh Media 3 Setup Wizard Setup has finished installing ooh Media 3 on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Figure 72 Completing the installation of ooh Media 3 sign software 3 Configuring the ooh Media 2003 sign settings 1 Open the sign software Start gt All Programs gt Adaptive Micro Systems gt ooh Media 3 gt ooh Media 3 Ai B E Tu Help Manual E IP Setup Utility KwikTrigger Referrence b ger 4 ooh Media 3 TE Quick Start Guide Tu Registration pes Tips and Tricks u Warranty Figure 73 Opening the ooh Media 3 sign software 2 Ifthe software was able to automatically detect your display during the loading of the ooh Media 3 software you will s
64. ng command is performed from within the Windows command prompt window also referred to as the DOS window To open the command prompt click the Start button and select Run A command window similar to the following appears c C WINDOWS system3 cmd exe Microsoft Windows XP Version 5 1 2666 lt C gt Copyright 1985 2661 Microsoft Corp U N gt Figure 35 Windows command screen 2 Type ping followed by the IP address of the unit as in the following example ping 192 168 1 2 A successful ping looks similar to the following c C WINDOWS system3 cmd exe Microsoft Windows XP Version 5 1 26001 lt C Copyright 1985 2661 Microsoft Corp Uz gt ping 192 168 1 16 Pinging 192 168 1 18 with 32 bytes of data Reply from 192 168 1 16 bytes 32 time 133ms TTL 126 Reply from 192 168 1 10 bytes 32 time 126ms TTL 126 Reply from 192 168 1 18 bytes 32 time 138ms TTL 126 Reply from 192 168 1 180 bytes 32 time 131ms TTL 126 Ping statistics for 192 168 1 1 Packets Sent 4 Received 4 Lost z loss gt Approximate round trip times in milli seconds Minimum 126ms Maximum 138ms Average 132ms IER Figure 36 Successful ping screen An unsuccessful ping looks similar to the following mar I Microsoft Windows Version 6 1 76611 Copyright lt c gt 2689 Microsoft Corporation All rights reserved Uz gt ping 192 168 1 231 Pinging 192 168 1 231 with 32 bytes of data Request timed out Request time
65. o flow behind the sign and to help hot air escape Natural Convection ID Sign Superstructure mounting bracket Hot air flow SS _ ____ 2 F Air ducts HA II i yi Cooler air flow E Cooler air flow Superstructure mounting bracket Monument Clearance requirements Superstructure mounting bracket Minimum clearance 1 inch Minimum clearance 6 inches Minimum clearance Superstructure 1 inch mounting bracket Monument Figure 9 Side view of single sign installed in a monument Forced Convection RECOMMENDED FOR HIGH TEMPERATURE ENVIRONMENTS Superstructure mounting bracket Air duct Hot air flow 4 FLA ad QU Install fans to pull cooler air into monument cavity Direct the fans toward the backs of the sign cases Air duct Superstructure mounting bracket E Monument Cooler air flow DO NOT allow water from the miso fascia trim or sign s door seams ory top of the sign JO NOT seal off air flow DO NOT allow water to pog underneath the sign DO NOT mount sig on the base e Monument EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 17 MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Monument installation double sided enclosure Natural Convection Vent Hot air Hot air flow flow Superstructur
66. ol TCP IP Properties dialog select Use the following IP address and enter the following Internet Protocol TCP IP Properties a General A Click Use the following IP address B Enter the following You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automaticall IP address 10 11 11 253 IP address E Subnet Mask 255 255 0 0 Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server set Ji Click OK Figure 7 Internet protocol properties Click OK to close the Local Area Connections Properties window Your computer is now in the same range as the sign s default IP address 10 11 11 254 Go to STEP 3 Installing sign software on page 12 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 9 APPENDIX IDENTIFY FIND AND CHANGE AN IP ADDRESS Windows Vista instructions 1 The sign must be powered on and connected to a computer through the connectivity option If applicable do not have the sign connected to a network at this time 2 At the computer click Start gt Control Panel gt Network and Internet gt Network and Sharing Center gt Manage network connections 3 Inthe Network Connections window right click Local A
67. omputer network page 41 All connectivity options require the computer or network to have the TCP IP Transmission Control Protocol Internet Protocol protocol installed and configured Today most operating systems include and install the TCP IP protocol by default For most people there is no need to look for this protocol However if you encounter communication issues we recommend contacting your network administrator The other requirement to getting your sign s to communicate with your network or computer is to assign it an IP address in the same range as your network or computer EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 33 CONNECTING SIGNS CONNECTIVITY OPTION OVERVIEW Ethernet option Using the Ethernet option you can connect the sign to your Ethernet network or to a computer with an Ethernet crossover cable To use this option your network must be using the TCP IP protocol This direct connection is most often used to install the sign If you are using this type of connection permanently make sure the Ethernet crossover cable is outdoor rated or inside weather tight conduit Rear view of sign Building wall a MS OO Computer running sign software Ethernet CAT5 crossover cable 300 foot maximum length Ethernet crossover cable must either be outdoor rated N or routed through weather tight conduit N S Figure 30 Overview of connecting a sign directly to a
68. over plate This side of the assembly faces away from the sign s o Do not tighten assembly 2 S S e e E Cf SS e using the compression nut amp e e SO Py S S N Q S N Oy S se e Si on Figure 38 Communication junction box EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 39 CONNECTING SIGNS 40 CONNECT THE SIGN S CONNECTIVITY OPTION 3 Route the Ethernet cable through the cover plate and plug it into the Ethernet port from the sign s PoE injector only fits one way on the bottom of the sign controller Ethernet port connectivity Plug the sensor s cable into the box connector port the connector Ethernet port from PoE p USB port not used Box connector sensor If applicable LVDS cable J Ethernet cable from WiFi Bridge If applicable temperature light sensor cable Figure 39 PoE injector connection 4 Secure the cover plate to the junction box being careful not to pinch or crimp the cable Compression nut 0o 2 eel cana pena A Carefully pull the slack out of the radius is 1 inch 0 cables when placing the cover plate back onto the sign B Secure the cover plate to the sign C Tighten each compression nut until s they are snug around the cable VV VY VV VV YN Y Y lt Figure 40 Securing the cover plate Note Route the cable s do
69. pplement ventilation outlets as needed Note Shading the back of the sign will enhance thermal performance Ventilation Basics How does the sign cool itself Since these LED displays are completely enclosed and in most situations require no forced air ventilation they rely on natural convection to cool their internal electronic components The top and back surfaces of the display act as heat sinks to cool the inside case temperatures Internal fans mix the air inside the case bringing it all to a more uniform temperature Excite EzView and StreetSmart displays are enclosed to keep out contaminants and prevent corrosion and dirt buildup which adversely affects the sign s performance and interferes with its ability to cool itself What is natural convection Natural convection is a type of heat transportation In natural convection air surrounding a heat source receives heat becomes less dense and rises The surrounding cooler air then moves to replace it This cooler air is then heated and rises and the process continues forming a convection current How does Adaptive define obstruction free space and why is so important Because proper air circulation is key to the optimal performance and longevity of your Adaptive LED display we recommend that there be a certain amount of open area on all sides of your display Bricking in or otherwise enclosing the case may cause overheating and other failures that will not be covered by your
70. r the temperature light sensor Install the temperature light sensor Only one temperature light sensor is used even in a master slave sign configuration In master slave sign configurations the master sign will relay the temperature readings and dimming settings to the connected slave sign gt Installing the temperature light sensor 1 Install the temperature light sensor according to the requirements and guidelines Route and secure the sensor cable s pathway to the back of the master sign s communication junction box 2 Remove the enclosure nut from the strain relief connector on the sensor cable Remove the enclosure nut Do not remove the rubber from the sensor cable P di enclosure gasket Figure 27 Strain relief connector s enclosure nut EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 31 CONNECTING SIGNS TEMPERATURE LIGHT SENSOR OPTIONAL Notice If you have a master slave sign configuration you must loosen the LVDS cable s compression nut on the master sign or damage to the sign controller may occur 3 Secure the strain relief connector to the master sign s communication junction box cover plate o UI A Remove four screws and the cover plate B Remove one of the 7 8 inch knock outs i for the strain relief connector C Secure the strain relief connector to the cover plate Enclosure nut Cover plate d di Do not tigh
71. rea Connection and choose Properties Note You may be asked for an administrator password contact your network administrator for the password or the prompt Windows needs your permission to continue will appear provide confirmation DD ES Network Conne e Search E Organze Views Y Disable this network device Name Status Device Name Connectivity LAN or High Speed Internet 1 we Local Area Connection A Right click Local Area Connection cw Network zd VIA Rh ne Disable Status Diagnose Bridge Connections Create Shortcut Delete Rename Rees i B Select Properties Figure 8 Local area connection 4 Select Internet Protocol Version 4 TCP IPv4 and click the Properties button oe Pity en aaa aaa Y Local Area Co nnection Properties EXA Networking Connect using amp VIA Rhine Il Compatible Fast Ethemet Adapter Configure This connection uses the following tems iv 0 Client for Microsoft Networks vl E QoS Packet Scheduler v fS File and Printer Sharing for Microsoft Networks Iv 4 Intemet Protacol Version E TCP IPv IA intemet Protaco Version 4 TCP IPv4 A Select Internet Protocol Version 4 TCP IPv4 Iv Link Layer Topology Discovery Mapper 1 0 Driver W 4 Link Layer Topology Discovery Responder ar B Click Properties button Figure 9 Local area connection properties Install 10 EZVI
72. rements on page 13 for details Sign painting or wrapping Notice Painting or vinyl wrapping the top and or the back of the sign will void the warranty The sides and bottom of the sign may be painted or vinyl wrapped without affecting the product warranty When painting the sign follow the paint manufacturer s instructions for surface preparation of mill finish aluminum Never paint or wrap the back or top of the sign Z CZ Painting or wrapping these areas will inhibit the ALLA 2 a ZZ sign s ability to cool through natural convection T SILLA E LEELA ETAPA D rr ALE Fa BLEED DLL JL rA LLLA LLLP LL Rear bottom view of sign A Front top view of sign Figure 6 Painting or wrapping the sign EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A MECHANICAL INSTALLATION SIGN INSTALLATION GUIDELINES AND REQUIREMENTS Ventilation requirements Notice Inadequate ventilation around the sign will ultimately result in sign component failure that may not be covered under warranty Introduction Adaptive s Excite EzView and StreetSmart displays require obstruction free space for adequate air ventilation between solid mounting surfaces and the top bottom and sides of the sign This is required for all wall monument and pole mounted signs Always take into consideration other neighboring heat sources such as backlit signs lighting sources etc and su
73. rs 0 9 in the Encryption Key 1 field Note Write down the encryption key in the space provided You will need this same key to configure security for the wireless Bridge unit 26 character encryption key LL EL LLL EL PL Pp 4 ILLE 4 Click Apply Changes 5 Click Close 6 On the Wireless Security Setup screen click Apply Changes EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 17 APPENDIX WIFI SETUP GUIDE Configure the Bridge Setup and configure the hardware 1 Swap the unit labeled Bridge with the Access Point you just configured 2 Open a web browser type 192 168 1 231 or the IP address labeled on the Bridge in the Address bar and press the Enter key 3 Atthe login prompt type admin for the Username and admin for the Password and click OK Figure 29 Wireless Bridge login prompt After you login in the screen appears similar to the following Oh Wireless Ciian Bridge 5E ILIP WENU MipernsnfE marna Esplarer Fle Ed Ves Fawonkes Tonk Help Address d htec ESO B 8 1 oras srp E D M ee F3 d n i Management Client Bridge Status A Settings Wireless Ties pepe boe the cireni elles cord some base dettes of the desser Ligon JSdurIihdmuila v1 37 lnfrastrucbacs Chal Beige JAGR LETER 3 Disabled onn an oe on Storm Ford IP Ve 16 1123322320 0000 Taeahled DOO BE ob Se Figure 30 Wireless LAN client Bridge screen Conf
74. s Enterprise RADIUS Personal Pre Shared Key WPA Cipher Suite TKIP AES WPA2 Cipher Suite TKIP AES Pre Shared Key Format Pre Shared Key Enable Pre Authentication Authentication RADIUS Server Pot LL E adarosg P asowara Note When encryption WEP is selected you must set WEP key value Figure 27 Wireless security setup screen 3 Click the Set WEP Key button The Wireless WEP Key Setup screen opens a http 192 168 1 2 WEP Key Setup Microsoft Internet Explorer Wireless WEP Key Setup This page allows you setup the WEP key value You could choose use 64 bit or 128 bit as the encryption key and select ASCII or Hex as the format of input value Key Length 128 bit v Key Format Hex 26 characters v Default Tx Key Keyl Y in Only use letters A F Encryption Key2 a 8 and numbers 0 9 for Encryption Key3 eene Encryption Key values Encryption Key 4 l Done 8D Internet Figure 28 Wireless WEP key setup window Although you can leave the WEP Key Encryption value at the default settings doing so would leave the sign and network susceptible to eavesdropping and hacking Consult the 11g Wireless Outdoor Client Bridge AP User s Manual or your networking professional for more information e For Key Length select 128 bit Set the Key Encryption Set at least the first key encryption value To do this enter 26 characters only letters A F and numbe
75. setup guide If the WiFi units are going to be used on an existing network confirm with your network administrator that the IP addresses listed are available If the WiFi unit IP addresses are already being used you must change the IP addresses see Changing the IP address for an Access Point or Bridge on page 20 for details WiFi units are shipped with the following IP addresses e Access Point transmitter 192 168 1 232 e Bridge unit receiver 192 168 1 231 e Each additional Bridge Starts at 192 138 1 233 and increments by 1 for example 192 138 1 234 192 138 1 235 and so on Configure the Access Point Note The following instructions for connecting the hardware are made a generic as possible due to the varieties and changes made by manufactures of PoE injectors and devices Always refer to the manufacturers documentation for definitive instructions on use of device Connect the hardware 1 Plug the Ethernet cable from the wireless unit labeled Access Point into the AP Bridge port of the Power over Ethernet PoE injector NOTE This is a generic view of a PoE injector Please follow the instructions supplied by the manufacturer of the PoE for connecting the Power Network and AP Bridge to the appropriate connection points cM e P BRIDGE O NETWORK GROUND Figure 22 PoE injector ports Plug an Ethernet cable from your computer or network into the Network port of the PoE injector 3 Plug the DC inlet
76. sign prior to servicing High leakage current and earth grounding WARNING It is essential to earth ground the sign before connecting the sign to a power source Contacting signs that are not earth grounded may cause death or serious injury Do not ground equipment to the sign before the sign itself is grounded This may cause death or serious injury and damage the sign and the equipment Other Other safety messages appear throughout this manual where appropriate EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 5 INTRODUCTION THIS PAGE INTENTIONALLY BLANK 6 EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A Equipment description Use this section to become more familiar with the sign s external and internal components Components shown in this section are critical to the sign s installation procedure Sign exterior Modular Cases and display boards EzView signs are modular case signs consisting of 1x3 1x4 and 1x5 cases or a combination of each size case Each 16x16 pixel area of a case is referred to as a display board or driver board A 1x3 case consists of three display boards a 1x4 case consists of four display boards and a1x5 case consists of five display boards Display board 16x16 pixels 1x4 case 16 pixels z lt 16 pixels gt Figure 1 Modular case and display boards EZVIEW X MODULAR CASE 20MM AND 23MM P
77. tat ate EXAMPLE Rear ew ofa display board 3 9 With DIP switch 3 5 and 7 ON the display board must be Pape R2 c5 positioned in Row 2 Column 5 R2 C5 of a master sign Figure 2 DIP switch settings for all EzView sign sizes Close the case door refer to Open the sign case on page 9 for details EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A APPENDIX IDENTIFY FIND AND CHANGE AN IP ADDRESS Identify find and change an IP address The sign and the computer network that will communicate with the sign must have IP addresses in the same range The following documentation provides detailed step by step procedures e STEP 1 Finding an available IP address for your sign STEP 2 Setting your computer s IP address to communicate with the sign e STEP 3 Installing sign software STEP 4 Changing the computer s IP address back to the original settings e STEP 5 Sending a test message to the sign gt STEP 1 Finding an available IP address for your sign Use one of the following methods e Contact your network administrator for an available IP Address in your network for the sign and go to STEP 2 Setting your computer s IP address to communicate with the sign on page 7 gt STEP 2 Setting your computer s IP address to communicate with the sign Windows XP instructions continue or go to Windows Vista instructions on page 10 1 The sign must be powered on and connected
78. ten assembly Loosen the compression nut using the compression nut to adjust the cable length Figure 28 Strain relief connector installation 4 Plug the sensor cable into the bottom box connector port on the sign controller Plug the sensor s cable into the box connector port the connector gt only fits one way on the bottom of the sign controller i If applicable E Ethernet port Ethernet port connectivity from PoE 4 USB port not used Box connector sensor Xx Temperature light sensor cable If applicable LVDS cable Figure 29 Temperature light sensor cable connection at the master sign Do not reattach the cover plate on the master sign it will be reattached later in the connectivity option 32 EZVIEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS CONNECTIVITY OPTION OVERVIEW Connectivity option overview Each master sign comes with a connectivity option Adaptive offers two options each of which you can use to connect the sign s to a computer or network An overview of each type of connectivity option is provided in this section Connectivity options Ethernet option kit direct cable connection between the sign and computer network page 37 p WiFi option kit wireless connection between the sign and computer network page 39 Fiber Optic Fiber optic option kit fiber connection between the sign and c
79. tions in high temperature climates may require the addition of fans to pull cooler air into the monument cavity and distribute this cooler air evenly across the back surface of the LED display cases Air Duct Ventilation installation for monument enclosed signs e Provide 3 5 square inches of ventilation obstruction free space for every 1 square foot of sign per face Consult the Ventilation Requirements Table e Ventilation air ducts MUST be installed across the top and bottom of the sign at evenly spaced intervals e Evenly spaced vents help maintain a consistent air flow around the sign Use 7 square inches if sign height exceeds 7 feet Figure 11 Monument enclosure ventilation EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 19 MECHANICAL INSTALLATION Pole Mounted Installation Correct spacing between ID Sign and LED Display Fe eee ee ee AE RT T M Incorrect spacing between ID Sign and LED Display TODD DAD V Figure 12 EzView sign pole installation If air flow is blocked display can overheat and malfunction Cooler air flow SIGN INSTALLATION GUIDELINES AND REQUIREMENTS DO NOT allow water to pool gather underneath or on top of the sign Always create a pathway for water to escape DO NOT drill or cut into the LED display case for ventilation purposes If the structure above the sign does not extend out past t
80. uirements iiiss mmm 30 Temperature MIGHESENSOF Installation GUIASINES 3 3 td c dt aged e o ee CO Pb eee tre ch esc 31 Metal Me Temperatures MORE SES OR ccs i uso lbs dotar iet ba e beca de genta be dre ord og ed Qe noe St dec ah 31 CONNEC ODIOM OVCIVICW p Staat doa aret ime hala iota adr ird SX v Ed xat Ganda cals acia s edu 33 EENE CODIO TR cour ching E ua LIMEN ME aU MUR MT E ctu t pi d ENA 34 WIPE OIESIGSS ODIO tro fonde erai E Rn ra ESTO ERO A doo agro Vc ritus RO E eds 35 ll ODBOI qs toG o uh EU aet Diod org ad od dd et cited a ETEA quit car E ar 36 Connect mesion Connec ONION x3 toos doeet A a oaa die i a Dat 31 Connect to tne sigmusingne EMPEORA ee HC heh 31 Connect o me SIGHMUSING NE VIE opio 4 aco beide eiie e ade deiecta aote aid dlc dece ot obo 39 Connect to the sign using the fiber optic option iiis mmm 41 Set ub tne sign to communicate on your network s voice aC e CY E CE RC DU RR RU DC CV de CN oA n 45 CONGU CE Ste SUD CV tra tr tat Tetas eC MUR eU eM ROE IO bok Pd eem ned edt 49 INSUMOS ISO WAS ERR E RITE ETE E ITI 51 OoniMdIa2009 SIgfi SOItWO G 6 24 55 39 p Xr fatte oe a X3 o eed a 51 oon ME IN SOW E ccc Rip Ae a Enel SO e Ron a eH esce ies Pe a Ul ae kes qoi anu doa ove ted daa a 54 APPENDI Caida aida dy PECHMICAS OCCINEQUONISS errar pira dore ON d y d durfte Peto aos 59 A se Doc dide de tee e eden de tete ot eee eee ee ee dod Pate ke ee 59 Display Board DIP SWICED SeLDIIO Sr 620 9088 dedos oed ond oe edle
81. wnward from the strain relief connector s directing water condensation build up to flow away from the sign s cable entry point EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A CONNECTING SIGNS CONNECT THE SIGN S CONNECTIVITY OPTION Connect to the sign using the fiber optic option gt Connecting to the sign using the fiber optic option 1 Mount the Fiber Optic Box up to 25 feet away from the sign Use the cable supplied with the box for maximum distance possible It is not recommended to mount the box further than 25 feet The box should not be mounted to the back of the sign with fasteners that penetrate the signs housing Figure 41 Fiber optic enclosure dimensions 2 Install the fiber optic enclosure Locate a site to install the fiber optic enclosure within 25 feet of the sign Installations over 25 feet are not recommended Do not mount the fiber optic enclosure on the sign with fasteners that penetrate the sign enclosure EZViEW X MODULAR CASE 20MM AND 23MM PITCH SIGN INSTALLATION MANUAL PN 1709610101 REV A 41 CONNECTING SIGNS CONNECT THE SIGN S CONNECTIVITY OPTION B Drill an opening near the Ethernet strain relief connector on the fiber optic enclosure for the water tight box connector C Secure the Attach the fiber optic enclosure to the mounting water tight box location Use 8 size screws or bolts and connector to the appropriate hardware mater
Download Pdf Manuals
Related Search
Related Contents
SIEMENS - Dimplex Istruzioni d`uso - VEGA Americas, Inc. Fujitsu CELSIUS H270 ChinaMed 2014 Service Manual Contact compagnie Handbuch - Ecopumpen.de CONTRAT DE LOCATION DES SALLES USER MANUAL 1.0.0 Powermate IH1195023 User's Manual la lettre des référents culture de l`académie de Toulouse Copyright © All rights reserved.