R16 InstalleR`s ManUal
Contents
1. ONBOARD SIREN FUNCTION BUTTONS PROGRAM ENTER BEEPER OUTPUT OUTPUT TYPE DESCRIPTION Ji SHORT BEEP Keypad Acknowledge key press dde 3 BEEPS RAPID Keypad Valid entry end of Exit Time 4 4 LONG BEEP Keypad Invalid entry Keypad beeper oJ 8 BEEPS RAPID Low battery AC Fail Medical Alarm a gt CONTINUOUS BEEPS Alarm Entry Delay etc Onboard Siren 1 CHIRP Arm External Siren output 3 CHIRPS Disain Onboard Siren DOORBELL TONES The Doorbell has been pressed Onboard Siren SIREN BURST Zone Auto Exclude warning External Siren output Low Volume Onboard Siren SIREN CONTINUOUS Alarm condition Piezo output External Siren output Strobe output STROBE BURST Panel Armed or Disarmed STROBE CONTINUOUS Alarm condition Arm disarm chirps must be enabled P64E 4E If the optional Radio Doorbell is available in your region E Ness R16 Installation and Programming Manual LCD DISPLAY KEYPAD DISPLAY IN OPERATING MODE DISPLAY OFF O ON 3 4 FLASHING ZONES 1 16 zone is sealed Zone is unsealed Zone alarm n zones or system auts Ready to Arm f ARMED Disarmed Armed uS Disarmed Monitor Mode t E MAINS ormal Mains Power is off ormal The panel s backup BATTERY battery is low M ALARM M Mode selected New al i MEMORY ormal emory Mode selecte ew alarms in memory e EXCLUDE ormal Zones a
2. Ness R16 Installation and Programming Manual EJ PROGRAMMING PROGRAM KEYPAD CODES PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT User Code 1 123 Installer Code 000000 All other codes blank Extra Option 1 all codes NOTES User Codes can be 3 to 6 digits in length Codes beginning with 0 zero can be programmed but they will not operate the panel this is an alternative method for disabling user codes The MEMORY E function is recommended for deleting user codes User Code 1 Master Code can be changed but it can not be deleted The MEMORY E sequence simply reverts User Code 1 back to factory default of 123 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected To clear all codes except the Installer Code enter P97E 3E in Installer Program mode See Page 45 Open Close reports are identified by user number when the control panel is central station monitored Shortcut arming ARM E if enabled is sent as User 25 RELATED OPTIONS P10E Program Radio Keys Options P11E P25E allow the programming or deletion of the 15 keypad codes and also setup the Extra Options for user code slots programmed with a Radio Key PROGRAMMING SEQUENCE 1 Press P user number option 11 25 E The existing keypad code will be displayed out one digit at a time on
3. normal entered in Decimal using B Star left or right 11 keypad digits 0 9 Cc ARM 12 D MONITOR 13 However if the account number is E EXCLUDE 14 required in Hex use this table when F MEMORY 15 programming P74E REPORT ZONE ALARMS PROGRAM MODE LEVEL This option selects the zones which will report alarms by dialler Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE 1 16 ON All zones report 1 Press P74E Alarms 2 Press 1 16 E to toggle each zone on or off RELATED OPTIONS Zone light s on indicates which option s are enabled P76E Report Zone Restorals PZE O REPORT MISCELLANEOUS ALARMS See page 38 lO P76E REPORT ZONE RESTORALS PROGRAM MODE LEVEL This option selects the zones which will report Restorals by dialler Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE 1 16 ON All zones report 1 Press P76E Restorals 2 Press 1 16 E to toggle each zone on or off RELATED OPTIONS Zone light s on indicates which option s are enabled P74E Report Zone Alarms P82E 1E 4E Sending Restorals Ness R16 Installation and Programming Manual EA PROGRAMMING REPORT MISCELLANEOUS ALARMS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E ON 3E ON 4E ON 5E ON 6E not used 7E ON 8E OFF RELATED OPTIONS P77E Report Miscellaneous Restorals This option selects the non zone events which will repo
4. 4E Report Fire Alarm 5E Report Tamper Alarm 6E not used 7E Report Keypad Tamper Alarm 8E Report Exit From Installer Mode Report Zone Restorals 1 16 All zones Report Misc Restorals see P75E for full list All ON Report Multiple Zone Alarms 1 16 All OFF P82E 1E _ Send Restoral Immediately when Resealed 2E Send Restoral After Siren Time amp Resealed 3E Send Restoral on Disarm Resealed 4E Send Restoral on Disarm always Test Call Interval 168 hrs Time Before Next Test Call O hrs P85E 1E Auto Pulse or DTMF depending on dial tone 2E Pulse Dialling always 3E DTMF Dialling always P86E 1E Disable Dialler Check For Dial Tone P88E 1E Open Close Reports 5E Alarm Cancel Report 6E Report Supervision Alarms ET Ness R16 Installation and Programming Manual Option No Description Default Page P89E Telephone Line Monitor P90E 1E Remote Access not used Remote Arming Remote Disarming Required Rings to answer incoming calls Clear Event Memory Factory Default Panel Options Factory Default Radio Zones Factory Default User Codes amp Radio Keys Program Installer Code 000000 Ness R16 Installation and Programming Manual EJ NESS LIMITED WARRANTY Ness Security Products Pty Ltd warrants its products to be free from manufacturing defects in materials or workmanship for the warranty period as d
5. OPERATION OPERATING MODES The R16 will operate in one of the following modes ARMED The system is On and ready to detect intrusion DISARMED The system is Off This is the normal mode when the premises are occupied Day Zones and 24 Hour Zones if configured are active DAY MODE The system is Disarmed and a zone or zones have been setup to create an alarm when activated Often used as a doorway alert in a shop See P53E Day Zones MONITOR MODE Allows the system to be partially Armed For example in a house to allow all perimeter zones doors and windows to be Monitored armed at night See P51E Monitor Zones 24HR ZONES Zones that have been setup to be active in any mode Usually used for Tamper switches and Panic buttons See P52E 24hr Zones DOORBELL If this product is available in your region The radio Doorbell operates in any panel mode The doorbell can be triggered using the Doorbell transmitter Most Ness transmitters can be programmed to operate the Doorbell function see page 25 Extra Option for Radio Keys See page 21 for doorbell volume and selectable chimes settings KEYPAD DISPLAY IN MEMORY REVIEW MODE EVENT DISPLAY ICONS Arm ARMED Disarm blank Auto Exclude Zone EXCLUDE 1 16 Mains Fail MAINS Panel Panic Medical Fire EXCLUDE Battery Fail BATTERY Line Fault LINE Dialler Call Fail LINE Zone Alarm 1 16 Tamper Panel Siren TAMPER Tamp
6. POE to P9E The leading zero is not necessary These phone numbers are used to report alarms in Ness Voice Dialling format and can be programmed from User Program mode or Installer Program mode Itis not necessary to program a reporting format Ness Voice Dialling format is automatically selected when alarm reports are sent to the Voice Dialling telephone numbers O voice Dialling is automatically disabled if Central Station telephone number s are programmed at P70E or P71E PROGRAMMING SEQUENCE 1 Press POOE or PO1E e The existing telephone number is displayed e It is not necessary to wait for the display sequence to end You can interrupt the display by entering the new telephone number 2 new telephone number E The new telephone number is displayed EXAMPLE To program Voice Dialling Phone No 1 to be 03 1234 1234 Press POOE 0312341234E TO CLEAR A TELEPHONE NUMBER To clear a telephone number enter the MEMORY key in place of the telephone number E g to clear Voice Dialling Phone No 2 press PO1E MEMORY E SPECIAL CHARACTERS Special characters such as Pauses star or hash characters can be included in a telephone number dialling sequence by using the keys in the table below SPECIAL KEYPAD KEYPAD CHARACTER ENTRY DISPLAYS PAUSE 1 6sec ARM Key 10 Star MONITOR Key 11 Hash EXCLUDE Key 12 EJ Ness R16 Installation and Programming Manual PROGRAMMING DOORBELL VOLUME
7. J R16 RADIO PANEL INSTALLER S MANUAL Ness R16 Radio Control Panel INSTALLATION PROGRAMMING MANUAL isi Head Office eed Ness Security Products Pty Ltd Company ABN 28 069 984 372 1509001 LGN Oca 4 167 Prospect Hwy NSW tes oniy Seven Hills NSW 2147 Australia Security Products Ph 61 2 8825 9222 Admin Fax 61 2 9838 8508 ness ness com au WWW ness com au SYDNEY Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au MELBOURNE MAD E Ph 03 9875 6400 Fax 03 9875 6422 4 IN nessmelb ness com au AUSTRALIA BRISBANE AMAS Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au vi PERTH Ph 08 9328 2511 Fax 08 9227 7073 nessper ness com au Australia s largest designer d ADELAIDE and manufacturer of Ph 08 8152 0000 Fax 08 8152 0100 high quality security products adelaide ness com au NESS R16 INSTALLATION MANUAL REV 1 March 2008 Document Part Number 890 320 For products 100 690 R16 Control Panel APPROVALS EMC COMPLIANCE EN 50130 4 1996 Part 4 Electromagnetic compatability Electrostatic Discharge Radiated RF Immunity Electrical Fast Transient burst Surge Immunity Conducted RF Immunity Voltage Dips and Interruptions Mains Supply Variations AS NZ CISPR 22 2002 Class B Electromagnetic Radiation Terminal Disturbance Voltage EN61000 6 3 2001 Harmonic Current Emissions Voltage fluctuations and Flicker TELECOM TBR21 EU PTC200 NEW ZEALAND TELECOM AS ACIF S002
8. PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 3 Volume level 3 NOTES The Doorbell sounds through the R16 onboard siren RELATED OPTIONS Doorbell Tune POGE Selects the doorbell volume Programmable range is volume level 1 lowest to 4 highest PROGRAMMING SEQUENCE 1 Press POBE Existing value is displayed 2 ENTER NEW VALUE E New value is displayed EXAMPLE To program Doorbell Volume to be Level 2 Press PO5E 2E POSE DOORBELL TUNE PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 3 Ding Dong NOTES RELATED OPTIONS Doorbell Volume PO5E The R16 has nine built in doorbell tunes to choose from The doorbell is activated by the optional Radio Doorbell transmitter Most Ness transmitters can be programmed to operate the Doorbell function see page 25 Extra Option for Radio Keys PROGRAMMING SEQUENCE 1 Press PO6E Existing value is displayed 2 ENTER NEW VALUE E New value is displayed EXAMPLE To program Doorbell Tune to be Tune 1 Westminster Press POGE 1E AVAILABLE TUNES Westminster Westminster 4 notes only Ding Dong Ding Dong Repetitive Star Spangled Banner Fur Elise Home Sweet Home Greensleeves Chime c o o001 0In f the optional Radio Doorbell is available in your region Ness H16 Installation and Programming Manual E PROGRAMMING POSE RADIO SIGNAL STRENGTH TEST
9. AUSTRALIA SAFETY EN60950 2000 inc Country Deviations Safety of Information Technology Equipment AS NZ3260 1993 incl AMDTS 1 2 3 amp 4 TS001 1997 ACA Australian Communications Authority NESS SECURITY PRODUCTS Australian Communications Authority Y TELECOMMUNICATIONS COMPLIANCE COPYRIGHT NOTICE All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement O 2008 Ness Security Products Pty Ltd ABN 28 069 984 372 CONTENTS INtTOdU CIO p EE 4 Specifications S 5 INSTALLATION Installation Notices er ia 6 Installation Procedures reine p e es ttp eti Hei Enter 7 GonnectioniDIiagram rd ee e e o e Eia elle 8 Inputs OutpUuls iro d o o d Pret adr ded 9 Keypad ou AE 10 Audible amp Visual feedback ooooonnnnccccocnncconnnanancncnnnonananonnannnnnnnananonononnnoncncnnanrnnnos 10 11 User TOS boite ste Nati a eee 11 OPERATION cut A a eh 12 Keypad Memory Display iiion aa dede de E edd deas 12 Operation Summar krenner ila el tart bae mede eh re qe deest 13 Alarm Type Descriptions i rie pret eite eo deri ttp ep teen 14 System Alarm Desc
10. EXCLUDE E Default ON P62E 3E MONITOR MODE SHORTCUT To enable or disable the Monitor Mode shortcut OFF Shortcut disabled MONITOR USER CODE E ON Shortcut enabled MONITOR E Default ON P62E 4E Not used P62E 5E ARMING SHORTCUT To enable or disable the Arming shortcut OFF Shortcut disabled ARM USER CODE E ON Shortcut enabled ARM E Default ON PROGRAMMING SEQUENCE 1 Press P62E 2 Press 1 5 E to toggle each option on or off Zone light s on indicates which option s are enabled P62E 7E SIREN BURST ON AUTO EXCLUDE PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 7 0N Enabled RELATED OPTIONS P60E 6E Auto Exclude Zones This option enables the 2 second siren burst at end of Exit Time which indicates a zone s has been Auto Excluded The siren burst is a low volume output from the onboard siren and the external siren PROGRAMMING SEQUENCE 1 Press P62E 2 Press 7E to toggle the option on or off Zone light on indicates the option is enabled E Ness R16 Installation and Programming Manual PROGRAMMING P64E 1E 8E MISCELLANEOUS OPTIONS 2 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E ON 3E not used 4E OFF 5E not used 6E ON 7E OFF 8E OFF PROGRAMMING SEQUENCE 1 Press P64E 2 Press 1 8 E to toggle each option on or off Zone light s o
11. PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0 Radio Key test NOTES The signal strength beeps will sound only the first time the radio device is activated The signal strength and device number remains flashing on the display until E is pressed again or the ON button of a valid radio key is pressed The Radio Signal Strength Test can be used to test the radio signal from any Ness radio device The strength of the radio signal received is displayed on the zone lights 1 9 and beeped by the keypad The higher the number displayed and beeped the stronger the signal received Use PO8E OE to test Radio Keys press Panic button Note that in this mode the R16 will respond to radio signals from any programmed radio device To avoid confusion from multiple radio signals this test is best performed while standing out of range of any programmed radio PIRs Use PO8E 1E 8E to test the signal strength of a specific radio device on zones 1 16 TO RESET THE TEST The last signal strength tested remains flashing on the display Press keypad E or Radio Key ON button to exit from the current test The panel is then ready for another radio test To completely exit the Radio Signal Strength test simply go to another programming option or exit Installer Program Mode P E EXAMPLE TO TEST THE SIGNAL STRENGTH OF A RADIO PIR ON ZONE 2 1 Press POBE 2E Radio icon and numeric icon 2 is flashing waiting for r
12. Required rings P90E 3E Remote arming P90E 4E Remote disarming NOTES If the R16 does not receive remote commands for periods longer than 60 seconds it will assume that the call is finished and it will hang up AUDIBLE FEEDBACK e 3 BEEPS Valid command user code J L 1 LONG BEEP Invalid command or user code try again SUMMARY OF TELEPHONE COMMANDS 0 PREPARE TO RECEIVE COMMANDS User Code VERIFIES THE USER 1 4 amm 2 C 8 DISARM HANG UP DIALLER OPERATION REMOTE TELEPHONE ARM DISARM The R16 can be armed and disarmed remotely using a standard fixed or mobile telephone To maintain panel security remote operations can only be activated after entering a valid user code To operate the R16 by telephone you need a DTMF capable telephone a valid User Code and you must know the Telephone number of the line to which the R16 is connected Program options P90E 3E and or 4E must be on to enable remote arming and or disarming Option P91E required rings to answer must be a value other than zero SEQUENCE OF OPERATION 1 Phone the R16 telephone number and listen for the required number of double rings and then hang up 2 Callthe number again within 60 seconds 3 The R16 will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The R16 is now ready to receive telephone commands 4 Pressthe 0 button
13. The zone is in learn mode Along beep indicates that the radio device may already be E programmed on another zone J 3 Connect the battery in the radio device Three beeps indicates device has been successfully programmed R15 Radio PIR EXAMPLE 1 To program radio zone 1 with a Ness Radio PIR 1 Press POSE 1E Zone 1 will start flashing j 2 Connectthe 9V battery to the Radio PIR TO DELETE A RADIO DEVICE To delete an existing Radio Device press PO9E select the zone R12 Radio PIR number to delete 1E 8E then press PO9E again EXAMPLE To delete the radio device programmed on zone 1 Press POSE 1E POSE RR1 Radio Reed Switch RR2 Universal Transmitter Ness R16 Installation and Programming Manual EJ PROGRAMMING PROGRAM RADIO KEYS PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT No radio keys programmed NOTES RELATED OPTIONS P11E P25E Program user codes Extra Options For Radio Codes page 25 HOW TO SEND THE LEARN MESSAGE RK4 RADIO KEY Press and hold Panic for 8 seconds RDB RADIO DOORBELL Press and hold for 8 seconds The R16 will accept up to 14 Ness Radio Keys to be used for remote control wireless Arming Disarming and Panic functions Radio Keys are programmed to one of the 15 User Code slots with the easy to use radio Learn mode A User Code slot can be either a keypad code or a radio key code not both User Code 1 is always
14. the keypad 2 Press new code E new code again E The new keypad code will be displayed on the keypad One beep will sound on the first entry of the new code three beeps will sound on the successful second entry of the new code EXAMPLE To program user code 2 to be 1234 1 Press P12E 1234E 1234E TO DELETE A CODE To delete a User Code enter the MEMORY key in place of the code Example To delete User Code 2 P12E MEMORY E For a list of user option numbers see the USER CODE OPTIONS TABLE on page 25 Open Close reports if enabled by your installer are identified by user number if the control panel is central station monitored EJ Ness R16 Installation and Programming Manual PROGRAMMING ENTRY DELAY TIME PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 20 20 seconds NOTES Programmable range is 1 99 seconds To view the programmed value without making changes press P26E The Entry Delay Time is the time given to Disarm the Panel on entry through an entry delay zone PROGRAMMING SEQUENCE 1 Press P26E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program the entry delay time to be 25 seconds P26E 25E EXIT DELAY TIME PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 60 60 seconds NOTES Programmable range is 1 99 se
15. Enables or disables sending of Open Close reports OFF Open Close reports disabled ON Open Close reports enabled PROGRAMMING SEQUENCE 1 Press P88E 2 Press 1E to turn the option on or off Zone light s on indicates the option is enabled P88E 5E ALARM CANCEL REPORT PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Cancel Report enabled NOTES This option is used to indicate to the Central Station that an alarm has been reset by a valid user Usually used in cases where Open Close reports are normally selected OFF A Cancel Report is sent when a Zone or Miscellaneous Alarm has been reset by a valid User Code or Radio Key disarming If enabled a cancel report will be sent after alarm Contact ID code 406 even if Open Close reports are disabled OFF Cancel Report disabled ON Cancel Report enabled PROGRAMMING SEQUENCE 1 Press P88E 2 Press 5E to turn the option on or off Zone light s on indicates the option is enabled P88E 6E REPORT SUPERVISION ALARMS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Report Supervision Alarms disabled RELATED OPTIONS P67E Radio Supervision Time This option enables the dialler reporting of Radio Supervision alarms OFF Report Supervision Alarms disabled ON Report Supervision Alarms enabled PROGRAMMING SEQUENCE 1 Press P88E 2 Press 6E to turn the option on or
16. Products is not an insurer of either property or safety of the user and limits its liability for any loss or damage including incidental or consequential damages to Ness original selling price There are no warranties expressed or implied which extend beyond the description on the face hereof Ness Security Products recommend that the system is tested weekly to confirm reliable operation
17. for this option Doorway alert for a shop To deselect a zone from this option program it to be Delayed Instant or Handover RELATED OPTIONS Zone light s on indicates which option s are enabled P64E 2E Brief Day alarm Programs the behaviour of Day Zone alarms EJ Ness R16 Installation and Programming Manual P60E 1E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON 2E not used 3E not used 4E ON 5E not used 6E ON TE OFF 8E OFF NOTES PROGRAMMING MISCELLANEOUS OPTIONS P60E 1E ENTRY BEEPS ON Enables keypad beeps during Entry Delay OFF No keypad beeps during Entry Delay Default ON P60E 2E Not used P60E 3E Not used P60E 4E TAMPER SIREN LOCKOUT OFF Tamper alarms can trigger multiple alarms ON Tamper Alarm lockout The siren output sounds once and then locks out if multiple Tamper Alarms occur The siren outputs become active again once the panel has been reset by a User Code Default ON P60E 5E Not used P60E 6E AUTO EXCLUDE ZONES OFF No AutoExclude an unsealed zone will alarm at the end of exit delay ON AutoExclude enabled If the panel is armed with an unsealed zone that zone will be Autoexcluded and the panel will give a 2 second Siren burst at the end of Exit Time to indicate that the panel is armed with a zone s Auto Excluded The 2 sec Siren burst can be disabled by option P62E 7E Default ON
18. on the telephone This tells the R16 that telephone commands will follow 5 Now enter a valid User Code followed by the st button The R16 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again 6 Enter the command to arm or disarm the panel See Summary Of Telephone Commands 7 Press to finish This tells the R16 to hang up Also hang up your telephone Ness R16 Installation and Programming Manual 49 NESS RADIO OPTIONAL ACCESSORIES 100 067 RK4 4 BUTTON RADIO KEY RK4 Radio Key is a fully sealed and fully waterproof four channel radio key with click action rubber buttons Functions ON OFF PANIC AUX The RK4 is a sealed unit powered by a Lithium battery with an expected life of 10 years 7 transmissions per day 100 664 RK3 3 BUTTON RADIO KEY RK3 Radio Key fully waterproof radio key Functions ON OFF PANIC Lithium battery supplied 100 683 RK1B RADIO KEY PENDANT Fully waterproof pendant style transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Includes long life lithium battery 100 056 RDB RADIO DOOR BELL The Ness Radio Doorbell requires almost no installation Long life lithium battery powered simply screw it to the wall The doorbell chime is heard through the R16 panel onboard siren Choose from one of 9 doorbell tunes built in to the R16 panel f
19. 1E Brief Monitor alarm PROGRAMMING SEQUENCE 1 Press P51E 2 Press 1 16 E to toggle each zone on or off Zone light s on indicates which option s are enabled ess ETS PROGRAM MODE LEVEL 24hr Zones operate at all times regardless of the mode of panel Installer Remote by PC operation e Armed Disarmed or Monitor When alarmed these zones will activate assigned outputs immediately To reset a 24hr FACTORY DEFAULT 1 16 OFF No 24hr zones zone alarm a valid user code must be entered y Selecting a zone as 24hr will override any other zone type setting NOTES such as Instant Delayed or Handover The Tamper input is always a 24hr zone PROGRAMMING SEQUENCE 1 Press P52E 2 Press 1 16 E to enable each zone for this option To deselect a zone from this option program it to be Delayed Instant or Handover Zone light s on indicates which option s are enabled Ness R16 Installation and Programming Manual EJ PROGRAMMING esa 0525s PROGRAM MODE LEVEL Day Zones operate when the panel is fully disarmed i e when fully Installer Remote by PC disarmed and Monitor mode is off When alarmed Day Zones will FACTORY DEFAULT activate the assigned outputs instantly 1 16 OFF No Day zones This option selects which zones will be Day Zones NOTES Typical uses PROGRAMMING SEQUENCE e Instant alert when a delivery 1 Press P53E door is opened 2 Press 1 16 E to enable each zone
20. 2E 2E Send Restoral after siren time amp resealed P82E SE Send Restoral on Disarm amp resealed P82E 4E Send Restoral on Disarm always PROGRAMMING SEQUENCE 1 Press P82E 2 Press 1 4 E to toggle each option on or off Zone light s on indicates which option is enabled Ness H16 Installation and Programming Manual EJ PROGRAMMING TEST CALL INTERVAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 168 168hrs 7 days NOTES To disable Test Reports program the test call interval to 0 zero hours RELATED OPTIONS P84E Time Before Next Test Call This option sets the time between Test Calls to the Central Station Programmable from 0 255 hours Enter a value between O and 255 A value of 0 zero disables test calls PROGRAMMING SEQUENCE 1 Press P83E The digits of the existing value will be displayed 2 Press new test call interval E The digits of the new value will be displayed TIME BEFORE NEXT TEST CALL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0 Ohrs Immediate on exit from installer program mode NOTES The Time Before Next Test Call is constantly updated When viewed the current value will be displayed not the initially entered value RELATED OPTIONS P83E Test Call Interval DAYS HOURS TABLE E a 2 OJON ajaj N o This option sets the time before the nex
21. 60 seconds Siren Reset Time 5 minutes The client code and telephone numbers are supplied by the central station E Ness R16 Installation and Programming Manual QUICK START RADIO PROGRAMMING As a radio system the R16 can be installed with a minimum of wiring If an external siren or strobe light is not being used the only essential wiring is connection of the plug pack The steps below will show you how to program one Radio PIR and one Radio Key O To enter Installer Program Mode To enter Installer Program Mode on initial power up apply power with the internal tamper open lid open or the external tamper open Or if you have powered up with all tampers sealed see below then press Ces es OODOOO OOGODOO 123 is the factory default This is User Program 000000 six zeros is the factory default This is Installer Progran Master Code Mode The PROGRAM Installer Code Mode The PROGRAM icon is on steady icon is flashing To program a Radio PIR amp Example to program a Radio PIR on zone 1 Press PO DE then press QD CE POSE is the option for Learn mode for zone 1 programming Radio Devices The RADIO icon will be on and the number 1 will be flashing The zone numbers for radio devices already programmed will be ON EZ Insert the battery of the Radio PIR to be programmed Beep beep 3 beeps will be heard if the RADIO PIR was successfully learned Zone icon 1 will then be on steady O
22. ABLE DIALLER PROGRAM MODE LEVEL This option disables the dialler even if telephone numbers and other Installer Remote by PC dialler options are programmed FACTORY DEFAULT Up download or remote telephone access remain enabled FF Dialler is enabled OFF This option is useful for temporary disabling of the dialler without NOTES affecting other dialler options The dialler can also be disabled by deleting all telephone numbers OFF The dialler is enabled The dialler will still remain disabled if no telephone numbers are programmed ON The dialler is disabled PROGRAMMING SEQUENCE 1 Press P86E 2 Press 1E to turn the option on or off Zone light s on indicates the option is enabled P87E 2E CHECK FOR DIAL TONE PROGRAM MODE LEVEL The dialler normally dials only if a dial tone is detected or it can be Installer Remote by PC forced to dial without a dial tone Allows use on PABXs with non FACTORY DEFAULT standard dial tones ON Check for dial tone OFF Does not check for dial tone NOTES ON Check for dial tone hang up on busy tone PROGRAMMING SEQUENCE 1 Press P87E 2 Press 2E to turn the option on or off Zone light s on indicates the option is enabled Ness R16 Installation and Programming Manual EN PROGRAMMING P88E 1E ENABLE OPEN CLOSE REPORTS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Open Close reports disabled NOTES
23. Delay Time Siren Reset Time Instant Zones Zones 3 16 Entry Delay Zones Zone 1 Handover Zones Zone 2 Reset Lockout Zones All zones Monitor Zones No zones 24hr Zones No zones Day Zones No zones Entry beeps not used not used Tamper Siren Lockout not used Auto Exclude Zones Keypad Backlight Blanking Disable onboard siren El Ness R16 Installation and Programming Manual INES Page 2 of 4 Option No Description Default Page P62E 1E Memory Display Shor tcut 2E Zone Exclude Shortcut 3E Monitor Mode Shortcut 4E not used 5E Arming Shortcut Siren Burst On Auto Exclude P64E 1E Brief Monitor Alarm 2E Brief Day Alarm 3E not used 4E Siren chirps Arm Disarm 6E Keypad Panic Alarm 7E Fire Alarm 8E Medical Alarm Pe5E 1E Radio Jamming Alarm 2E Radio Substitution Alarm Radio Supervision Time Radio Key Arming Warning Central Station Telephone No 1 Central Station Telephone No 2 Client Account No m Options marked u can be programmed in User Program Mode m E All options can be programmed in Installer Program Mode Ness R16 Installation and Programming Manual EJ INES Page 3 of 4 Option No Description Default Page Report Zone Alarms 1 16 All zones P75E 1E Report Duress Alarm 2E Report Medical Alarm 3E Report Panic Alarm
24. ING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 4 0FF disabled NOTES Setting this option on allows an external siren chirp warning if there is an unsealed zone when the panel is armed by a Radio Key otherwise only internal beeper warning is given OFF Radio Key Arming Warning disabled ON Radio Key Arming Warning enabled Default OFF PROGRAMMING SEQUENCE 1 Press P68E 2 Press 4E to toggle the option on or off Zone light on indicates the option is enabled Ness R16 Installation and Programming Manual EJ PROGRAMMING P70E P71E CENTRAL STATION TELEPHONE NUMBERS 1 amp 2 PROGRAM MODE LEVEL The telephone numbers programmed at P70E P71E are used to Installer Remote by PC report alarms to a central station in Contact ID format FACTORY DEFAULT It is not necessary to program a reporting format Contact ID format Both Telephone Numbers is automatically selected when alarm reports are sent to the Central blank Station telephone numbers NOTES If P7OE or P71E is PROGRAMMING SEQUENCE programmed non blank 1 Press P70E or P71E then Ness Voice Dialling e The existing telephone number is displayed format is disabled POOE e It is not necessary to wait for the display sequence to end You can POE interrupt the display by entering the new telephone number 2 new telephone number E RELATED OPTIONS ia POOE PO1E Ness Voice The new telephone number is display
25. OUS RESTORALS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 8 ON All Miscellaneous Alarms report Restorals RELATED OPTIONS P75E Report Miscellaneous Alarms This option selects the miscellaneous alarms which will report Restorals by dialler See P75E page 38 for a list of Miscellaneous Alarms PROGRAMMING SEQUENCE 1 Press P77E 2 Press 1 8 E to toggle each option on or off Zone light s on indicates which option s is enabled REPORT MULTIPLE ZONE ALARMS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 16 OFF All zones report alarms once only RELATED OPTIONS P74E Report Zone Alarms Zones selected to Report Multiple Zone Alarms will report each time the zone alarms The number of reports is a maximum of 15 Zones not selected will report only once until reset by an opening or a valid code PROGRAMMING SEQUENCE 1 Press P78E 2 Press 1 16 E to toggle each zone on or off Zone light s on indicates which option s is enabled RESTORAL REPORTING OPTIONS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 4E ON Send Restoral on Disarm always RELATED OPTIONS P74E Report Zone Alarms This option selects when the dialler sends Zone Restoral Reports Only one of the following options may be selected Restoral reporting options also apply to 24hr zones P82E 1E Send Restoral immediately when resealed P8
26. P60E 7E KEYPAD BACKLIGHT BLANKING OFF Keypad Backlighting is always on ON Keypad Backlighting blanking enabled The backlighting on the keypad can be programmed to blank after 4 minutes of no keypad use Any action that causes a beep will restore the back lighting or press E to manually restore backlighting Default OFF P60E 8E DISABLE ONBOARD SIREN OFF Onboard Siren enabled ON Onboard Siren disabled When the onboard siren is disabled keypad beeps are still active but are disabled during an alarm condition Keypad beeps will be reactivated on the next disarm This option also disables the PIEZ internal screamer output Default OFF PROGRAMMING SEQUENCE 1 Press P60E 2 Press 1 8 E to toggle each option on or off Zone light s on indicates which option s are enabled Ness H16 Installation and Programming Manual EN PROGRAMMING OPERATION SHORTCUTS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON 2E ON 3E ON 4E not used 5E ON Some keypad operations can be programmed to operate with or without a User Code P62E 1E MEMORY DISPLAY SHORTCUT To enable or disable the View Memory shortcut OFF Shortcut disabled MEMORY USER CODE E ON Shortcut enabled MEMORY E Default ON P62E 2E ZONE EXCLUDE SHORTCUT To enable or disable the Zone Exclude shortcut OFF Shortcut disabled EXCLUDE USER CODE E ON Shortcut enabled
27. TTERY lt BACK HOUSING o Q MOUNTING HOLES p Slotted x 4 07 U LLL B WIRING gt OV ground for accessories 100mA max Hardwired Zone Input 2K2 EOL resistor OV ZONE TAMP U N O Tamper Switch I e a Strobe Light Max Qty 1 External Screamer Max Qty 1 SIREN PIEZ PIEZ External Horn Speaker Max Qty 1 Xx 17VAC Earth Plug Pack 17VAC 300mA Supplied QD QD O qp QD O O O O am Lac al Lsme TERMINAL BOARD gt 12V for accessories 100mA max ES Ness R16 Installation and Programming Manual INPUTS OUTPUTS INPUTS ZONE Zone input for optional hardwired detection devices Operates in series with any radio devices on zone 16 The input must be terminated with a 2K2 2200 ohm end of line EOL resistor even if unused This input is normally used for connecting an optional hardwired reed switch or a 12V powered smoke detector TAMP 24hr input for connection of external tamper switches This input operates in series with the internal tamper switch The input must be terminated with a 2K2 2200 ohm end of line EOL resistor even if unused AC EARTH AC power input and earth connection Use the supplied 17V AC 300mA plug pack OUTPUTS SIREN Timed siren output for connection of maximum one 1 8 Ohm horn speaker 2A Auto reset fuse protected STR Output
28. To program a Radio Key Example to program a Radio Key to user slot 2 Press POE then press Qe P10E is the option for Learn mode for User 2 programming Radio Keys The RADIO icon will be on and the number 2 will be flashing Numbers 2 15 show the status of the user slots ON Radio Keys programmed OFF blank flashing learn mode Q Press and hold the PANIC button for 8 seconds on the Radio Key to be programmed Beep beep 3 beeps will be heard if the RADIO KEY was successfully learned Number 2 will then be on steady A long beep means the Radio Key is already programmed to another user slot See page 24 Q To exit Installer Program Mode Press P followed by E The PROGRAM icon will turn off Ness H16 Installation and Programming Manual 17 This page is intentionally blank ES Ness R16 Installation and Programming Manual USER PROGRAM MODE User Program Mode allows the owner to program All User Codes Entry and Exit times Note The panel will automatically drop out of User Program Mode to Operating Mode if no keypad buttons are pressed for 4 minutes INSTALLER PROGRAM MODE Installer Program Mode allows access to ALL program options Note The panel will remain in Installer Program Mode indefinitely Factory default Master Code 123 Factory default Installer Code 000000 PROGRAMMING PROGRAM MODE LEVELS Power up with the box lid open Usually on firs
29. a keypad code PROGRAMMING SEQUENCE 1 Press P10E e The RADIO icon will turn on and zone numbers 2 15 will show which user code slots have radio devices programmed 2 Press user number 2 15 E The selected user number is flashing The user slot is in learn mode Along beep means the Radio Key may already be programmed to another user slot 3 Press the required Radio Key button to send the Learn message See How To Send The Learn Message e Three beeps indicates the radio key has been successfully programmed EXAMPLE To program a Radio Key to user slot 2 Press P10E 2E then press and hold the PANIC button on the Radio Key TO DELETE A RADIO KEY To delete an existing Radio Key press P10E select the user number to delete 2E 15E then press P10E again EXAMPLE To delete the Radio Key on user slot 2 Press P10E 2E P10E RKP RADIO KEYPAD Insert the battery or consult the Radio Keypad manual RK1B RADIO PANIC Press 3 times f the optional Radio Doorbell is available in your region EI Ness R16 Installation and Programming Manual FACTORY DEFAULT Extra Option 1E Panic is the factory default for all user slots NOTES When programming the Radio Doorbell the Extra Option for that user slot must be 5E Each user code slot is defaulted with Extra Option 1E enabled Panic alarm The Extra Option for a user code slot can be programmed after a radio key has been programmed to t
30. ad Codes and Radio Key codes Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE not applicable 1 Press P97E 2 Press 3E Factory defaults are restored Ness R16 Installation and Programming Manual ES DIALLER OPERATION DIALLING SEQUENCE The dialler follows the re dial procedure shown until the message is successfully reported The dialler cycles around the Panel telephone numbers skipping numbers not programmed If P70E or P71E are programmed then the Voice Dialling numbers POOE and PO1E are ignored A successful report is defined as a report which has been kissed off by the Central Station or by a hash tone in the case of Audible Format dialling to a private number 1 Dial Central Station Ph No 1 P70E and report alarms in Contact ID format If not kissed off 2 Dial Central Station Ph No 2 P71E and report alarms in Contact ID format 3 If P7OE and P71E are blank dial Voice Dialling Ph No 1 POOE and report alarms in Ness Voice Dialling format If not kissed off 4 If P70E and P71E are blank dial Voice Dialling Ph No 2 PO1E and report alarms in Ness Voice Dialling format Accumulate maximum of 15 failed attempts Attempt to dial unsuccessful numbers a second time after 30 seconds a total of 10 attempts Wait 5 minutes then subsequent attempts are 1 hour apart A maximum of 15 dial attempts for the same event New events re start the sequence at 1 NED OTE No more
31. adio data 2 Trigger the radio device on zone 2 3 The display will alternate flashing signal strength value and radio key detector slot number E g The signal strength will be flashed on the display and the panel will beep signal strength value Then the radio icon and detector key number will be on steady EXAMPLE TO TEST THE SIGNAL STRENGTH OF A RADIO KEY 1 Press PO8E OE Radio icon is flashing waiting for radio data 2 Press and hold the Panic button for 2 seconds on the Radio Key being tested 3 The display will alternate flashing signal strength value and radio key slot number E g The signal strength will be flashed on the display and the panel will beep signal strength value Then the radio icon and detector key number will be on steady 22 Ness R16 Installation and Programming Manual PROGRAMMING PO9E PROGRAM RADIO DEVICES PROGRAM MODE LEVEL The R16 has sixteen radio zones which can accept Ness radio devices Installer Remote by PC such as radio PIRs radio reed switches radio smoke detectors FACTORY DEFAULT Each of the sixteen radio zones will accept one radio device No radio devices programmed Radio devices are programmed with the easy to use radio learn mode PROGRAMMING SEQUENCE 1 Press PO9E e The RADIO icon will turn on and zone numbers 1 16 will show which zones have radio devices programmed 2 Press zone number E The selected zone number is flashing
32. ansmission from device with low battery turn them off when a transmission from a device without a low battery is received Indicates a low battery condition A low battery alarm occurs when the detector operates Flash the BATTERY RADIO and zone number icons LOW BATTERY Control Panel RADIO SUPERVISION FAIL Radio PIR or Fixed Radio Panic Button The control panel backup battery is periodically load tested A low battery condition is cleared when the battery passes load test Battery is tested once every 1 hour and on every disarm Flash the BATTERY icon A radio supervisory message or other message has not been received from a detector for the programmed supervision period Flash the RADIO and zone number icons MAINS POWER FAIL Indicates AC mains power to Panel is not connected or power is off Flash the MAINS icon FAIL TO COMMUNICATE Indicates the dialler was not able to successfully contact the central monitoring station Flash the LINE icon All alarm types can be reported to the Central station See page 48 for a full list of Contact ID reporting codes Ness R16 Installation and Programming Manual 15 QUICK START PANEL PROGRAMMING The R16 is supplied pre programmed with factory default values that should suit most installations The steps below will show you how to program the Master Code User Code 1 and the Client Code and telephone number for central station monitoring O To enter Ins
33. conds To view the programmed value without making changes press P28E The Exit Delay Time is the time given to secure and exit the premises after the R16 is Armed All zones except 24hr zones are inactive during the Exit Delay time PROGRAMMING SEQUENCE 1 Press P28E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program the exit delay time to be 50 seconds P28E 50E SIREN RESET TIME PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5 5 minutes NOTES Programmable range is 1 10 minutes To view the programmed value without making changes press P29E The Siren Reset Time sets the alarm duration of the Siren and Reset outputs PROGRAMMING SEQUENCE 1 Press P29E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program the siren reset time to be 4 minutes P29E 4E Ness H16 Installation and Programming Manual 27 PROGRAMMING INSTANT ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 3 16 ON Zones 3 16 are instant NOTES When a zone is selected as Instant it is automatically deselected from Entry Delay or Handover Instant Zones operate only in the Armed state Once armed at the expiry of exit time Instant Zones will activate assigned outputs imm
34. d encrypted messages are received a minimum time apart the alarm is raised 2 ENCRYPTION HACKING In this case an attempt is made to crack the encrypted changing part of a message using multiple transmissions If 20 messages are received with a valid ID but fail decryption the alarm is raised Arming and disarming resets this count The dialler reports a radio jamming radio substitution alarm RADIO JAMMING After accumulating a no radio signal reference level 10 minutes after power up the system will raise a radio jamming alarm if 30 seconds of continuous in band radio signal is detected DIALLER LINE FAULT Indicates minimum telephone line DC voltage was not detected for a 2 minute period If Telephone Line Monitor is enabled flash the LCD LINE icon and beep keypad E Ness R16 Installation and Programming Manual SYSTEM ALARM DESCRIPTIONS System Alarm indication icons are active in all Operate modes All system alarms sound beeper until the E key is pressed If the panel is armed the beeper is sounded on disarm While the alarm persists the beeper is sounded on each disarm System alarms can be reported if the system is monitored by a central monitoring station ALARM TYPE DESCRIPTION LOW BATTERY Radio Key Radio Panic Radio Doorbell LOW BATTERY Radio PIR Indicates a low battery condition A low battery alarm occurs when the key operates Flash the BATTERY and RADIO icons after a tr
35. e Panic button for at least 2 seconds 9 User Code E To disarm and report a silent Duress alarm to the monitoring station add the digit 9 before a valid user code when disarming Extra Options for the Panic Option P75E 1E must be on to enable the button must be set for Duress dialler to report the alarm P12E P25E 2E EXCLUDING ZONES Zones can be Excluded in the disarmed state then enter the zone number s E for each zone to be Excluded Zone No E Zone No E then press to exit Exclude mode VIEW MEMORY Memory can be viewed in the disarmed state Shortcut method Arming shortcut must be on P62E 5E 5 then press repeatedly to display the last 20 events in memory then press E to exit Memory mode Ness R16 Installation and Programming Manual 13 ALARM TYPE DESCRIPTIONS ALARM TYPE DESCRIPTION ALARM Detector A zone goes unsealed in a mode causing an alarm Non restoring detectors which have alarmed will send a Restore report on Disarming if Restore reporting is enabled Restoring detectors e g a reed switch programmed with Restore which have alarmed will report a Restore only when they are sealed if Restore reporting is enabled TAMPER Panel Siren Panel housing tamper switch and external siren housing tamper switch are wired to the same Tamper Input When alarmed will report a Restore only when sealed if Restore r
36. ed Dialling Format Telephone EXAMPLE Numbers 1 amp 2 page 20 To program Central Station Telephone No 1 to be 03 1234 e P86E 1E Disable Dialler 1234 page 41 Press P70E 0312341234E ar TO CLEAR A TELEPHONE NUMBER Dialling Sequence page 46 To clear a telephone number enter the MEMORY key in place of the telephone number E g to clear Central Station Telephone Number 1 press P7OE MEMORY E SPECIAL CHARACTERS Special characters such as Pauses star or hash characters can be included in a telephone number dialling sequence by using the keys in the table below SPECIAL KEYPAD KEYPAD CHARACTER ENTRY DISPLAYS PAUSE 1 6sec ARM Key 10 Star MONITOR Key 11 Hash EXCLUDE Key 12 EJ Ness R16 Installation and Programming Manual PROGRAMMING P72E CLIENT ACCOUNT NUMBER PROGRAM MODE LEVEL The 4 digit Client Account Number identifies the panel to the central Installer Remote by PC station when reporting alarms in Contact ID format The number can FACTORY DEFAULT be entered and reported in Decimal or Hex 0000 PROGRAMMING SEQUENCE 1 Press P72E The digits of the existing value will be displayed 2 Press new account number E The digits of the new value will be displayed This is to program the account number in Decimal See below for Hex EXAMPLE To program the Account Number to be 1234 P72bE 1234E HEX ACCOUNT NUMBER HEX KEYPAD KEYPAD The Client Account Number is DIEM DISPLAY
37. ediately when triggered PROGRAMMING SEQUENCE 1 Press P40E 2 Press 1 16 E e This enables the zone for this option To deselect a zone from this option program it to be Entry Delay or Handover e Zone light on indicates the option is enabled ENTRY DELAY ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 ON Zone 1 is Delayed NOTES When a zone is selected as Entry Delay it is automatically deselected from Instant or Handover Entry Delay zones operate only in the Armed state When Armed at the expiry of exit time these zones will activate the Entry Delay Timer P26E when they are triggered If the panel is not disarmed before the expiry of the Entry Delay Timer the alarm outputs will be activated PROGRAMMING SEQUENCE 1 Press P41E 2 Press 1 16 E to enable each zone for this option e To deselect a zone from this option program it to be Instant or Handover Zone light s on indicates which option is enabled HANDOVER ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 2 ON Zone 2 is Handover NOTES When a zone is selected as Handover it is automatically deselected from Entry Delay or Instant Handover zones are delayed only if entry is made through an Entry Delay zone first If a Handover zone is triggered first the zone behaves as an instant zone Normally the point of entry zone should be Delay zone with any othe
38. eporting is enabled TAMPER Keypad Detect entry of consecutive invalid codes in Armed mode alarm sirens on 4 failed attempt TAMPER Radio detector Radio detector housing tamper switch activation When alarmed will report a Restore only when sealed if Restore reporting is enabled PANIC Keypad Instant when both PANIC buttons pressed together or ii delayed when either PANIC button is pressed and held for 1 5 seconds PANIC Radio Press and hold the device PANIC button for the required length of time DURESS Keypad Enter a valid code prefixed with a 9 The response is the same as for a keypad Panic alarm but no sirens or strobe are active DURESS Radio With a radio key programmed as Duress press and hold the device PANIC button for the required length of time No sirens or strobe are active MEDICAL Keypad Press and hold Right Hand keypad Star key for 2 seconds MEDICAL Key With a radio key programmed as Medical press and hold the device PANIC button for the required length of time FIRE Keypad Press and hold Left Hand keypad Star key for 2 seconds This triggers the fire siren sound and the dialler reports a Fire alarm if enabled by P75E 4E RADIO 1 CODE GRABBER SUBSTITUTION A code grabber may be used to capture a transmitted user message and re transmit a fixed copy of this message in an attempt to defeat the system If two consecutive identical vali
39. er 4 failed attempts TAMPER PROGRAM Radio Jamming RADIO Radio Substitution RADIO Radio Key Low Battery RADIO BATTERY 2 15 Radio Key Panic Medical RADIO EXCLUDE Detector Tamper RADIO TAMPER 1 16 Detector Low Battery RADIO BATTERY 1 16 Detector Supervision Fail RADIO 1 16 Pendant Supervision Fail RADIO MONITOR 1 15 12 Ness R16 Installation and Programming Manual ACTION OPERATION SUMMARY KEYPAD OPERATION RADIO KEY OPERATION ARM The panel must be in the disarmed state first Arming with a user code User Code E Shortcut method Arming shortcut must be on P62E 5E Press The ON button once arm E DISARM Press the OFF User Code E button once MONITOR MODE Arming Monitor with a user code Press the ON button The panel must be in the User Code E alce Wiha disarmed state first MN Shortcut method Monitor shortcut must seconds Note The panel will ignore be on P62E 3E Monitor Mode arming if no i monitor zones are selected at P51E PANIC ALARM 4 A Press the Keypad Panic is indicated on the LCD display by the EXCLUDE icon flashing Press both star keys together Panic shortcut must be on P62E 3E Panic button for at least 2 seconds DURESS ALARM Duress alarm should only used by arrangement with your monitoring station Press th
40. etailed in Ness Terms and Conditions of Sale and all other obligations detailed in those Terms and Conditions Whilst Ness Security Products the manufacturer is accredited to ISO9001 and all possible care and diligence has been applied during manufacture to ensure the reliable operation of this unit there are various external factors that MAY impede or restrict the operation of this unit in accordance with the product s specification These factors include but are not limited to 1 Failure to communicate to the monitoring company due to a telephone service provider s line fault or due to the incorrect configuration of the telephone Product to the Telephone Network It is the responsibility of a qualified Installer to ensure correct configuration to the telephone network 2 Erratic or reduced radio range as detailed in the manufacturer s specifications Ness radio based products are sophisticated low power devices however the presence of in band radio signals high power transmissions or interference caused by electrical appliances e g computers televisions etc MAY reduce the range performance Whilst such occurrences are unusual they are possible none the less If a problem such as this is encountered and the performance is unsatisfactory the installer of the product should be contacted immediately 3 Unauthorised tampering physical damage electrical interruptions such as mains failure electrical spikes or lightning Ness Security
41. for connection of 1 x strobe light As a power saving feature the strobe output times out after 11 hours If mains power is off the output will time out after 1 hour 1 5A Auto reset fuse protected PIEZ Timed output for connection of maximum 1 x 12V screamer 500mA Auto reset fuse protected ONBOARD SIREN Built in The onboard piezo siren is an integral part of the R16 electronics It is used for keypad beeps doorbell chime arm disarm chirps and internal siren on alarm The internal Siren can be disabled by program option P60E 8E When the Internal Siren function is disabled the onboard siren still outputs keypad beeps and other audible features 500mA Auto reset fuse protected 12V SUPPLY FOR ACCESSORIES If 12V power is required for a device such as a hardwired smoke detector use Zone Input OV negative and SIREN positive No more than 100mA should be drawn from these terminals Ness H16 Installation and Programming Manual EN R16 KEYPAD AUDIBLE amp VISUAL FEEDBACK The R16 onboard keypad provides the facility for user level and installer level programming and all user operation and emergency functions The keys are soft touch silicon rubber and are backlit for high visibility Any keypress will turn on the backlighting for 4 minutes ARMED ARM2 ALARM MEMORY BACKLIT LCD DISPLAY FIRE MEDICAL PANIC
42. ged both telephone numbers will be alternately dialled up to a maximum of 15 attempts per alarm event ACKOWLEDGING THE ALARM The person receiving the call can acknowledge the alarm by pressing the key on their telephone Press the key for 2 seconds during pauses in the audible message On mobile phones press the key in short bursts Many mobile phones enter sub menus if the key is pressed continuously When the alarm is acknowledged the dialler will hang up and not make any more calls Further alarms on other zones will restart the dialling sequesnce Ness R16 Installation and Programming Manual EA DIALLER OPERATION CENTRAL STATION MONITORING MONITORING STATION MONITORED PREMISES TELEPHONE LINE RESTORAL REPORTS Restores are always sent for the following alarms when the device alarm condition is physically removed 137 Siren box tamper 302 Panel low battery 383 Tamper Detector 381 Radio device supervision poll fail Restores are always sent for the following alarms on disarming when a valid code is entered if Restores are enabled 101 Radio Key Medical alarm 120 Panic alarm 121 Duress alarm 130 Burglary alarm 133 24 hour alarm 355 Radio jamming alarm CENTRAL STATION MONITORING The dialler sends alarm reports to a central station using Central Station Telephone numbers 1 and 2 P70E amp P71E Page 36 It is not necessary to program a reporting format Alarm rep
43. hat slot PROGRAMMING EXTRA OPTIONS FOR RADIO CODES Each user code slot has five Extra Options which control the behaviour of Radio Keys and the Radio Doorbell transmitter when they are programmed to a user code slot on the R16 The Extra Options are 1E Panic The Panic Button will trigger the audible Panic alarm default 2E Duress The Panic Button will trigger the silent Duress alarm See P75E 1E 3E Medical The Panic Button will trigger the Medical alarm 4E Ignore Panic Disables Panic Button on radio keys 5E Doorbell The Panic Button will sound the R16 doorbell feature PROGRAMMING SEQUENCE FOR EXTRA OPTIONS 1 Press P user number option 12 25 E e If a Radio Key is programmed to the user slot the RADIO icon will be on Icons 1 5 show which Extra Option is currently selected 2 Press 1 5 E e This selects a new Extra Option EXAMPLE A Radio Key is programmed to User Code slot 2 To change the Extra Option to Ignore Panic press P12E 4E USER CODE OPTIONS TABLE RADIO CODES KEYPAD CODES USER CODE SLOT DESCRIPTION OPTION NOs OPTION NOs DEFAULT User Code 1 Master Code User Code 2 P10E 2E User Code 3 3E User Code 4 4E User Code 5 5E User Code 6 6E User Code 7 7E User Code 8 8E User Code 9 9E User Code 10 10E User Code 11 User Code 12 User Code 13 User Code 14 User Code 15 Always a Keypad Code
44. is 000000 PROGRAMMING SEQUENCE 1 Press P 99 E e The existing installer code will be displayed 2 Press new installer code E new installer code again E The new installer code will be displayed One beep will sound on the first entry of the new code three beeps Will sound on the second entry of the new code if the code was successfully programmed EN Ness R16 Installation and Programming Manual PROGRAMMING ENNIO conse eony PROGRAM MODE LEVEL This option erases the Event Memory as well as memory locations Installer Remote by PC where events and time stamps are stored for uploading status FACTORY DEFAULT PROGRAMMING SEQUENCE 1 Press P96E The Event Memory is erased not applicable P97E 1E FACTORY DEFAULT PANEL OPTIONS PROGRAM MODE LEVEL This option erases all program options and restores the factory Installer Remote by PC default values There are no exceptions This defaults all program FACTORY DEFAULT options not applicable PROGRAMMING SEQUENCE 1 Press P97E 2 Press 1E Factory defaults are restored P97E2E FACTORY DEFAULT RADIO ZONES PROGRAM MODE LEVEL This option erases all Radio Zones programmed by option PO9E Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE not applicable 1 Press P97E 2 Press 2E Factory defaults are restored P97E 3E FACTORY DEFAULT USER CODES PROGRAM MODE LEVEL This option erases all Keyp
45. is not turned on at this stage Connect siren wires and external tamper inputs as required 6 Replace the battery POWER UP PROCEDURE The power up procedure assumes that installation of the R16 is completed and the plug pack is wired 7 Connectthe battery lead to the BATTERY socket on the main board 8 Turn on the plug pack Note 1 When power is applied the R16 will enter Disarmed mode unless it was in Armed or Monitor mode when previously running in which case it will resume in the previous mode UNLESS the box tamper or external tamper inputs are unsealed See note 2 Note 2 To enter Installer Program Mode on initial power up apply power with the internal tamper open lid open or the external tamper open Note 3 The BATTERY icon will flash if the initial battery voltage is low and will turn off when the battery has reached full charge Ness R16 Installation and Programming Manual Ka CONNECTION DIAGRAM Bottom L o FRONT HOUSING gt rear an oO XR 3 E Em INTERNAL TAMPER o RA SWITCH 2 a 3 Battery g z Hn MAIN VERTU E BOARD S o o DA 11 L 3 o EE TERMINAL gegeseosegon do SEO MESS CABLE ENTRY z poe E 12V 0 8AH BA
46. list label 2K2 resistors re uper ek ek E 0 0 Removing the Front housing BACK HOUSING a ir i LIII T Cable entry via cavity wall CONDUIT TERMINAL BOARD CABLE TIE o BACK HOUSING 0 ITI II Cable entry via conduit INSTALLATION INSTALLATION PROCEDURE The location of the main panel housing should be in an area that is within the protected area of the premises A linen closet or cupboard are good examples as these are generally located in the centre of the premises 1 Remove the front housing by first removing the bottom locking screw screw is not fitted for shipping then unclip the bottom of the front housing and lift upwards 2 Disconnect the 12 way wire loom from the main board on the front housing 3 Unclip and remove the terminal board from the back housing and remove the battery The battery lead connects to the main board on the front housing It is not plugged in for shipping The terminal board and battery must be removed to reveal all four mounting holes in the back housing 3 Mount the back housing to the wall using the 4 slotted mounting holes 4 Replace the Terminal Board in the back housing and reconnect the 12 way wire loom to the main board 5 Connectthe plug pack wiring to the Terminal Board making sure that mains power
47. man body can generate static electricity when it is insulated from earth for instance by walk ing over carpet ESD occurs and a small shock is sometimes felt if an earthed metal object is then touched The installer should be aware that if he generates static electricity while installing the panel and then discharges this static electricity into the internal components on the main circuit board or the keypad board then ESD damage may occur The circuit board should not be unwrapped until it is actually ready to be installed Methods to avoid electrostatic build up 1 Use a foot strap a wrist strap or a grounding mat The aim is to connect the body to earth to discharge static before it builds up The connection is a high resistance for personnel safety If the above is not available then it is advisable to wear clothing that will minimise the build up of static Handle circuit boards by the edges Avoid touching any components on the board as the inte grated circuits in particular are not guaranteed by their manufacturers to be safe from ESD To minimise the build up of static avoid walking around as much as possible while working on the installation Touch an earthed object to discharge any static before working on the installation EN Ness R16 Installation and Programming Manual PACKING LIST R16 Control panel Plug pack 17VAC 300mA Battery 12V 0 8Ah Telephone lead User manual Installer manual Zone
48. n indicates which option s are enabled P64E 1E BRIEF MONITOR ALARM This option programs the behaviour of alarms in Monitor Mode OFF NORMAL MONITOR ALARMS Outputs are on for the Siren Reset Time and dialler reporting is enabled ON BRIEF MONITOR ALARM Outputs are on for 2 seconds internal piezo at half volume strobe There is no dialler report no external piezo and no external siren Default OFF P64E 2E BRIEF DAY ALARM This option programs the behaviour of Day Zone alarms OFF NORMAL DAY ALARMS Siren amp Reset output will be on while a Day Zone is unsealed ON BRIEF DAY ALARM Outputs are on for 2 seconds internal piezo at half volume strobe There is no dialler report no external piezo and no external siren Default ON P64E 3E Not used P64E 4E SIREN CHIRPS ARM DISARM When this option is enabled the external siren output and the onboard siren will chirp on arm disarm by radio key The strobe output always flashes on arm disarm by radio key independent of this program option 1 chirp arming 3 chirps disarming OFF Siren chirps disabled ON Siren chirps enabled Default OFF P64E 5E Not used P64E 6E KEYPAD PANIC ALARM Keypad Panic can be triggered by pressing both star keys together The dialler reports a Panic alarm if enabled by P75E SE OFF NO KEYPAD PANIC ON KEYPAD PANIC IS ENABLED Default ON P64E 7E FIRE ALARM The Fire Alarm can be t
49. ndard DTMF telephone or mobile phone OFF Remote Arming is disabled ON Remote Arming is enabled Default OFF P90E 4E REMOTE DISARMING Allows the remote Disarming of the control panel using a standard DTMF telephone or mobile phone OFF Remote Disarming is disabled ON Remote Disarming is enabled Default 2 OFF PROGRAMMING SEQUENCE 1 Press P90E 2 Press 1 4 E to toggle each zone on or off Zone light s on indicates which option s are enabled Ness H16 Installation and Programming Manual E PROGRAMMING REQUIRED RINGS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 12 1 double ring NOTES Sets the number of double rings before an incoming call is answered This is used for Remote Access Programmable from 1 to 16 rings Enter a value between 1 and 16 PROGRAMMING SEQUENCE 1 Press P91E The digits of the existing value will be displayed 2 Press required rings E The digits of the new value will be displayed PROGRAM THE INSTALLER CODE PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 000000 NOTES The Installer code cannot begin with the digit O zero The Installer code can be changed but it cannot be deleted Any attempt to delete the installer code will make it revert back to the factory default of 000000 Programs the installer code This code can be 3 to 6 digits long The factory default installer code
50. off Zone light s on indicates the option is enabled 42 Ness R16 Installation and Programming Manual PROGRAMMING P89E 5E TELEPHONE LINE MONITOR PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Telephone Line Monitor disabled NOTES When enabled the panel will test the telephone line every 20 seconds Ifthe telephone line is not found the keypad LINE icon will commence flashing If the line fault continues for 2 minutes then the keypad beeps a warning OFF Telephone Line Monitor disabled ON Telephone Line Monitor enabled PROGRAMMING SEQUENCE 1 Press P89E 2 Press 5E to turn the option on or off Zone light s on indicates the option is enabled UP DOWNLOAD OPTIONS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E not used 3E OFF 4E OFF NOTES Option P90E 1E Remote Access applies only to upload download by computer and modem If PSOE 1E is disabled remote Arm Disarm is still available if options P90E 3E and or 4E are on and P91E is not zero These options enable remote upload download features P90E 1E REMOTE ACCESS When selected on this option allows the panel to be remotely upload downloaded by a remote computer OFF Remote Access is disabled ON Remote Access is enabled Default 2 OFF P9OE 2E Not used P90E 3E REMOTE ARMING Allows the remote Arming of the control panel using a sta
51. orts are automatically sent in Contact ID format to the telephone numbers programmed at P70E and or P71E Events are reported to the central station using the Contact ID format as follows SSSS 18 Q XYZ GG CCCE SSSS18 Client Account Number 4 Contact ID identifier Q Event qualifier 1 New Event 3 Restore XYZ Event code GG Group Number always 00 CCC Qualifier 0 9 User ID uu Zone ID zz or Unique Code 030 099 E Checksum CONTACT ID REPORTS CONTACT ID CODE REPORT NAME alez jes menm Zone Alarm q 130 Ozz Yes Zone 24 Hour Alarm q 133 Ozz Yes Keypad Panic q 120 032 Yes Keypad Radio Key Duress q 121 1uu Yes Keypad Medical q 100 033 Yes Keypad Fire q 110 034 Yes Radio Key Panic q 120 1uu Yes Radio Key Medical q 101 1uu Yes Radio Detector Supervision q 381 4zz Radio Panic Button Supervision q 381 1uu Radio Jamming or Substitution q 355 060 Panel Siren Tamper q 137 040 Yes Keypad Tamper q 137 042 Yes Radio Sensor Tamper q 383 3zz Yes Mains Fail q 301 050 Panel Battery Low q 302 052 Radio Detector Battery Low q 384 3zz Open Disarm 1 401 Ouu Close Arm 3 401 Ouu Shorcut Arm ARM E 3 401 025 Cancel Disarm 1 406 Ouu Zone Manual Exclude q 573 Ozz Zone Auto Exclude q 380 Ozz Exit Install mode 1 306 035 Test Report 1 602 063 ES Ness R16 Installation and Programming Manual RELATED OPTIONS P91E
52. programming amp user functions LCD DISPLAY High contrast icon display PLUG PACK 220 240V AC 50 60Hz output 17V AC 300mA QUIESCENT CURRENT DRAW 10 mA in power save mode if mains is off BUILT IN BACKUP BATTERY 12 volt 0 8 Amp hour sealed lead acid DYNAMIC BATTERY TEST Every Hour and on arming disarming FUSES Siren Output 2A Auto reset Strobe Output 1 5A Auto reset Piez Output 500mA Auto reset Built in Piezo 500mA Auto reset SIREN OUTPUT 1x8 Ohm horn speaker max ON BOARD PIEZO SIREN 110 dB PIEZ RESET OUTPUT 12V DC 300mA max STROBE OUTPUT 12V DC 1 strobe light max DIMENSIONS 210 w x 145 h x 40 d mm Ness R16 Installation and Programming Manual 5 INSTALLATION WARNING Installation and maintenance shall be performed by qualified service personnel only CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions on the battery ESD WARNING Electrostatic Discharge ADSL NOTICE ADSL broadband data can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines in all premises with an alarm dialler installed Once properly installed Ness control panels are well protected from ESD However take note of the following precautions during installation The hu
53. r zones in the entry path programmed as Handover zones PROGRAMMING SEQUENCE 1 Press P42E 2 Press 1 16 E to enable each zone for this option To deselect a zone from this option program it to be Delayed or Instant Zone light s on indicates which option s are enabled EJ Ness R16 Installation and Programming Manual PROGRAMMING P4E RESET LOCKOUT ZONES PROGRAM MODE LEVEL All zones can be programmed to Lockout i e cause the RESET Installer Remote by PC OUTPUT to sound only once whilst the panel is armed FACTORY DEFAULT The RESET OUTPUT is then locked out for that alarmed zone until 1 16 ON All zones are entering a valid code has reset the panel Lockout zones NOTES PROGRAMMING SEQUENCE This option applies to the 1 Press P44E RESET output the SIREN output always locks out 2 Press 1 16 E to toggle each zone on or off Zone light s on indicates which option s are enabled RELATED OPTIONS P60E 4E Tamper Reset Lockout PSIE O MONITOR ZONES PROGRAM MODE LEVEL This option selects which zones will be armed in Monitor mode Installer Remote by PC y Monitor zones allow you to Arm selected zones while others are FACTORY DEFAULT ignored Typically used for perimeter zones such as windows and 1 16 OFF No Monitor doors while you are at home Example Upstairs zones are Disarmed zones while downstairs zones are Armed in Monitor mode RELATED OPTIONS P64E
54. re excluded LT TAMPER ormal Tamper alarm 9 ormal Receiving radio signal Indicates that a Radio Key or A RADIO g g other radio device has a low battery A f Phone line fault or LINE ormal Dialler is on line failure to communicate PROGRAM ormal User Program Mode Installer Program Mode The flashing RADIO fault icon could be indicating that the radio key device has either low battery or supervision failure or other radio related problems The numeric display 1 15 will show which device is sending the signal See page 19 The table KEYPAD DISPLAY IN MEMORY REVIEW MODE provides further detail KEYPAD BEEPER NOTE If the onboard siren is disabled P60E 8E on keypad beeps are also disabled during an alarm condition Keypad beeps will be reactivated on the next disarm USER TESTS Test functions can be invoked by pressing and holding the specified keypad button as follows The Panel must be in Disarmed mode BUTTON TEST PERFORMED 9 Dialler Listen in Press and hold keypad button 9 for 3 seconds to enable the Dialler Listen in function All dialler tones are output through the onboard siren This allows the installer to hear dial tone dialling tones central station handshake and kiss off tones This test automatically turns off after 2 minutes E Display Test Press and hold keypad button E for 1 5 seconds Turns on all LCD icons while the button is pressed Ness R16 Installation and Programming Manual 1
55. riggered by pressing the FIRE key for at least 2 seconds left hand STAR key This triggers the fire siren sound and the dialler reports a Fire alarm if enabled by P75E 4E OFF No Keypad Fire Alarm ON Keypad Fire Alarm is enabled Default OFF P64E 8E MEDICAL ALARM The Medical Alarm can be triggered by pressing the MEDICAL key for at least 2 seconds right hand STAR key The keypad beeper will sound 8 warning beeps The dialler reports a Medical alarm if enabled by P75E 2E OFF No Medical Alarm ON Keypad Medical Alarm is enabled Default OFF Ness H16 Installation and Programming Manual EN PROGRAMMING RADIO JAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E OFF 2E OFF NOTES Radio Jamming and Radio Substitution alarms if enabled are reported to the central station and displayed by the RADIO icon on the LCD display P65E 1E RADIO JAMMING ALARM The R16 will raise a radio jamming alarm if 30 seconds of continous in band radio signal is detected Note The R16 needs to be powered up for a minimum of 10 minutes to obtain a no radio signal reference level before it is able to detect a radio jamming signal OFF Radio Jamming Alarm disabled ON Radio Jamming Alarm enabled Default OFF P65E 2E RADIO SUBSTITUTION ALARM The Radio Substitution alarm helps protect against 1 Code Grabber A code grabber may be used to capture a transmi
56. riptions i oet e o E p hat E coe Pede 15 Quick Start Panel Programming essen 16 Quick Start RADIO Programming esssseeeeeneenenneeneeneee nennen 17 PROGRAMMING usaste 19 How to enter Program Mode oooocococcccnoccnocccnonccnnnncnnon nro nn raro ron emen nnne 19 PANEL PROGRAMMING OPTIONS sse nennen nennen 20 35 DIALLER PROGRAMMING OPTIONS esee eene 37 43 FACTORY DEFAULT OPTIONS adni deie ekora 45 Diallet Operatior n er aa DU oni EE ced rua 46 Audible Voice Diallirig 1 tirer tribe et eter neg te 47 Central Station Monitoring esiis i e onea eaaa nnne enne enne 48 Contact ID reporting codes sesessssssseseeeeeneeenenne nennen nnne 48 Remote Telephone Operation esssssseeeeeeeeeeennee nnne 49 Radio ACCESSOMOS si necs Pret ree EE lidia Tirano Socr canada 50 51 PROGRAM OPTIONS SUMMARY 52 55 INTRODUCTION The Ness R16 is a unique fully self contained radio control panel The panel has a built in keypad for programming and user operation a built in piezo siren built in LCD display built in radio receiver built in battery backup and built in dialler The R16 supports up to 16 Ness Radio PIRs and up to 14 Ness Radio Keys All Ness supervised and encrypted radio devices are supported There is even a Doorbell feature with selectable tunes when used with the Ness Radio Doorbell transmitter If
57. rt alarms by dialler P75E 1E REPORT DURESS ALARM OFF Duress Alarm reporting is disabled ON Duress Alarm reporting is enabled Default OFF P75E 2E REPORT MEDICAL ALARM OFF Medical Alarm reporting is disabled ON Medical Alarm reporting is enabled Default ON P75E 3E REPORT PANIC ALARM This option applies to keypad panic and radio key panic OFF Panic Alarms reporting is disabled ON Panic Alarms reporting is enabled Default ON P75E 4E REPORT FIRE ALARM OFF Fire Alarm reporting is disabled ON Fire Alarm reporting is enabled Default ON P75E 5E REPORT TAMPER ALARM This option applies to panel tamper and external tamper OFF Tamper Alarm reporting is disabled ON Tamper Alarm reporting is enabled Default ON P75E 6E Not used P75E 7E REPORT KEYPAD TAMPER ALARM Reports entry of consecutive invalid codes in Armed mode alarm on 4th failed attempt OFF Keypad Tamper Alarm reporting is disabled ON Keypad Tamper Alarm reporting is enabled Default ON P75E 8E REPORT EXIT FROM INSTALLER MODE OFF Exit From Installer Mode reporting is disabled ON Exit From Installer Mode reporting is enabled Default OFF PROGRAMMING SEQUENCE 1 Press P75E 2 Press 1 8 E to toggle each option on or off Zone light s on indicates which option s are enabled EJ Ness R16 Installation and Programming Manual PROGRAMMING REPORT MISCELLANE
58. t test call and is used to set the preferred time for Test Calls Programmable from 0 255 hours Enter a value between 0 and 255 A value of 0 zero triggers the next test call immediately on exit from Installer program Mode PROGRAMMING SEQUENCE 1 Press P84E The digits of the existing value will be displayed 2 Press new time before next test call E The digits of the current value will be displayed PROGRAMMING EXAMPLE To set the time before the first test call E g If you are programming the panel at 5pm and you want test calls to be sent at 1am Enter P84E 8E 5pm 8hrs 1am P83E and P84E timers start on exit from Installer program Mode 40 Ness R16 Installation and Programming Manual PROGRAMMING POSE CALLING uero PROGRAM MODE LEVEL The dial format is determined by the detected Dial Tone By default Installer Remote by PC if no dial tone is detected after looping the line then the dialler will attempt to dial regardless alternating between PULSE Decadic first FACTORY DEFAULT pare ON Automatic Pulse or DTMF and then DTME dialling NOTES P85E 1E Automatic PULSE or DTMF determined by the detected dial tone E f P85E 2E Pulse Dialling always Turning ON one of the options P85E 3E DTMF Dialli will turn OFF any other mene aang aways PROGRAMMING SEQUENCE 1 Press P85E 2 Press 1 3 E to turn an option on Zone light s on indicates which option is enabled P86E 1E DIS
59. t time installation INSTALLER PROGRAM Mode PROGRAM LIGHT IS FLASHING P E P INSTALLER CODE E Factory default Installer Code 000000 t mp E t P MASTER CODE E Factory default Master Code 123 NORMAL OPERATING Mode PROGRAM LIGHT IS OFF HOW TO ENTER PROGRAM MODE FROM POWER UP 1 Power up with the internal box tamper or external tamper open The R16 will then be in Installer Program Mode USING THE KEYPAD The panel must be Disarmed dcs Press P MASTER CODE E The keypad will respond with 3 beepss This is User Program Mode PROGRAM light is ON 2 Then press P INSTALLER CORE The keypad will respond with 3 beeps sae This is Installer Program Mode PROGRAM light is FLASHING HOW TO EXIT PROGRAM MODE 1 Press P then E This is Operating Mode PROGRAM light is OFF Ness R16 Installation and Programming Manual 19 PROGRAMMING POOE PO1E VOICE DIALLING TELEPHONE NUMBERS 1 4 2 PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT Both Telephone Numbers blank NOTES These program options can also be accessed by pressing POE and P1E The leading zero is not mandatory RELATED OPTIONS P70E P71E Central Station Telephone Numbers 1 4 2 page 36 Ness Voice Dialling format see page 47 Dialling Sequence page 46 GENERAL NOTE Program options POOE to PO9E can also be accessed by pressing
60. taller Program Mode To enter Installer Program Mode on initial power up apply power with the internal tamper open lid open or the external tamper open Or if you have powered up with all tampers sealed see below then press gx es OOOOO E OOGODOO 123 is the factory default This is User Program 000000 six zeros is the factory default This is Installer Prograr Master Code Mode The PROGRAM Installer Code Mode The PROGRAM icon is on steady icon is flashing To program the Master Code Example to program the Master Code to be 1234 Press PUE DOOM OOOO P11E is the option for Enter the new Master Code Enter the new Master Code again the Master Code followed by E followed by E To program the dialler Client Account Number Example Client Code is 9876 Press PADRE YOOOO P72E is the option for Enter the new Client Account the Client Code Number followed by E To program the central station telephone number Example telephone number is 1234 7890 Press POE DOSIDOVE P70E is the option for Enter the new telephone number followed by E Telephone Number 1 Q To exit Installer Program Mode Press P followed by E The PROGRAM icon will turn off THE PANEL IS NOW PROGRAMMED AS FOLLOWS Master Code 1234 Dialler Client Account Number 9876 Central Station Telephone number 1 1234 7890 Zone 1 Delay Zone 2 Handover Zones 3 16 Instant Entry Delay Time 20 seconds Exit Delay Time
61. than 20 dial events will be reported between each disarming of the panel MESSAGE QUEUE The panel places event reports in a queue Multiple simultaneous reports or reports previously unsuccessfully dialled will be included in the current call The oldest report on the queue is sent first If the queue is full 8 messages a new report will overwrite the oldest report The current dialler queue is cancelled and the dialler buffer is erased on entry to installer program mode ES Ness R16 Installation and Programming Manual AUDIBLE MONITORING MONITORED l TELEPHONE LINE ANY TELEPHONE PREMISES NOTE The R16 can be monitored by Central Station or by Voice Dialling to a private phone but not by both simultaneously Any telephone numbers programmed in options P70E amp P71E must be erased to allow the Voice Dialling telephone numbers to work Ask your installer DIALLER OPERATION NESS VOICE DIALLING The dialler sends alarm reports to a private telephone mobile telephone or fixed telephone using Voice Dialling Telephone numbers 1 and 2 POOE PO1E ENABLING VOICE DIALLING Voice Dialling Format is enabled simply by programming the Voice Dialling phone number options POOE and PO1E See side note Central Station Monitoring must be disabled to enable Voice Dialling OPERATION The word ALARM is repeated for 30 seconds until the alarm is acknowledged see below Ifthe alarm is not acknowled
62. the optional Radio Doorbell is available in your region 100 283 RPB RADIO EMERGENCY BUTTON The Ness Radio Emergency Button is designed to be wall mounted as an easy to install alternative to hardwired emergency buttons Long life Lithium battery is supplied 100 001 RKP RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the control panel as well as operating Home Mode and provides a Panic alarm m iz ES Ness R16 Installation and Programming Manual NESS RADIO OPTIONAL ACCESSORIES 100 663 R15 RADIO PIR The Ness R15 Radio PIR has a detection range of 15m automatic temperature compensation and vertical creep zones Features Radio Supervision and Encryption when used with a compatible Ness control panel With Pulse Count battery saving mode and low battery reports 9V Lithium battery supplied 100 663PET R15 PET AWARE RADIO PIR The Ness R15PET Pet Aware model detects humans but is immune to PET AWARE JA household pets Allows you to protect your home with your pets inside 100 691 R12 RADIO PIR Radio PIR with 12m detection range and automatic temperature compensation Features Radio Supervision and Encryption when used with a compatible Ness control panel With Pulse Count battery saving mode and low battery reports 9V Lithium battery supplied Ness Quantum mounting bracket supplied 100 662 RR1 RADIO REED SWITCH Ness Radio Reed S
63. the radio doorbell is available in the local frequency In addition to radio devices the R16 has 1 hardwired zone and 1 hardwired tamper input for connection of a wired detection device and external siren cover tamper switch RADIO DOOR SWITCHES RADIO DETECTION The built in piezo siren provides high volume audible warning The R16 also has Siren Piezo and Strobe outputs for additional hardwired noisemakers The R16 has a number of sophisticated power saving features designed to provide at least 48 hours service running on the backup battery alone This includes one full alarm condition with sirens strobe and dialler The built in dialler uses Contact ID format for central station monitoring as well as audible monitoring to any telephone The user can also dial into the system for remote arming and disarming over the telephone line RADIO KEYS RADIO DOORBELL PLUGPACK Supplied MENMI L PHONE LEAD Supplied ZONE INPUT HARDWIRE EXTERNAL SIREN OUTPUT STROBE OUTPUT TAMPER INPUT INTERNAL PIEZO OUTPUT Ness R16 Installation and Programming Manual SPECIFICATIONS RADIO ZONES 16 HARDWIRED ZONES 1 operates in series with zone 16 HARDWIRED TAMPER ZONES 1 RADIO COMPATIBILITY DIALLER FORMAT Ness supervised amp encrypted radio devices Contact ID Format Audible Voice Format ON BOARD KEYPAD Backlit
64. tted user message and re transmit a fixed copy of this message in an attempt to defeat the system If 2 consecutive identical valid encrypted messages are received a minimum time apart the alarm is raised 2 Encryption Hacking In this case an attempt is made to crack the encrypted changing part of amessage using multiple transmissions If 20 messages are received with a valid ID but fail decryption the alarm is raised Arming and disarming resets this count OFF Radio Substitution Alarm disabled ON Radio Substitution Alarm enabled Default OFF PROGRAMMING SEQUENCE 1 Press P65E 2 Press 1 2 E to toggle each option on or off Zone light s on indicates which option s are enabled ET Ness R16 Installation and Programming Manual PROGRAMMING RADIO SUPERVISION TIME PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0 disabled NOTES RELATED OPTIONS P88E 6E Report Supervision Alarms The SUPERVISION TIME is the time allowed between radio transmissions received by the R16 from any Supervised Radio Detector The SUPERVISION TIME setting is from 1 to 168 hours Supervision is disabled by setting time of O zero PROGRAMMING SEQUENCE 1 Press P67E The digits of the existing value will be displayed 2 Press new time E The digits of the new value will be displayed EXAMPLE To program Radio Supervision Time to be 6 hours P67E 6E P68E 4E RADIO KEY ARMING WARN
65. witch for wireless door and window protection Includes long life lithium battery 100 527 RR2 MULTI PURPOSE TRANSMITTER The Ness Universal Transmitter is a 9V battery operated transmitter with onboard reed switch an external input and vibration analyser The external input can be used to take inputs from normally closed reed switches or emergency buttons This allows connection of any type of N C switch or button to send an alarm signal The external input can also be used to connect a Nessensor vibration sensor for completely wireless vibration sensing with sensitivity adjustment 106 040 RSM RADIO SMOKE DETECTOR The Ness Radio Smoke Detector provides a wireless smoke detection option which can sound the R16 siren s and dialler if required or as programmed by your installer The Ness Radio Smoke Detector uses Photo electric smoke detection technology On board sounder and test button for the sounder and radio transmitter A single battery powers the smoke detector and the transmitter Includes 9V lithium battery Ness R16 Installation and Programming Manual EB INES Page 1 of 4 Option No Description Default Page Voice Dialling Format Tel No 1 Voice Dialling Format Tel No 2 Doorbell Volume Doorbell Tune Radio Signal Strength Test Program Radio Devices Program Radio Keys P11E Program Master Code Keypad Code 1 P12E P25E Program Keypad Codes 2 15 Entry Delay Time Exit