Home

led power blinder 400 user manual

image

Contents

1. Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew TROUBLE SHOOTING Listed below are a few common problems the user may encounter with solutions Unit not respond to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin is hot on some other DMX devices pin 5 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Specifications Model LED Power Blinder 400 Working Position Any safe working position Voltage 90 250V 50 60Hz Power 400W LED Lamp Top level high power leds Warm White 100Watts 4pcs Optical lens 80 Color temperature 3200 3500K DMX Channel 4 8 channel mode Manual pendulum angle left to right 20 Waterproof rate IP20 Ne
2. Down keys to select desired Mode settings Press Enter to confirm the setting Dimmer Mode 1 This function allows you to select dimmer mode to have long delayed dimming Press Enter to use Up Down keys to select desired Mode settings Press Enter to confirm the setting Dimmer Mode 2 This function allows you to select dimmer mode2 to have longer delayed dimming Press Enter to use Up Down keys to select desired Mode settings Press Enter to confirm the setting Dimmer Mode 3 This function allows you to select dimmer mode3 to have longest delayed dimming Press Enter to use Up Down keys to select desired Mode settings Press Enter to confirm the setting No Dimmer Delay This function allows you to select dimmer mode to have no delayed dimming Press Enter to use Up Down keys to select desired Mode settings Press Enter to confirm the setting DMX Chart 4 001 Mode 8 DMX Channels LED1 202 intensity LED3 LED4 50 intensity LED2 LED4 intensity LED1 LED3 50 intensity 120 129 LED1 LED2 LED3 intensity 130 139 LED1 LED2 LED3 LED4 intensity 140 149 LED2 LED3 LED4 intensity CHANNEL VALUE FUNCTION 0 255 LED1 intensity 0 255 LED2 intensity 0 255 LED3 intensity 0 255 LED4 intensity
3. LED POWER 400 User Manual i ___ PLEASE READ THIS MANUAL BEFORE OPERATION Unpacking Thank you for purchasing LED Blinder 400 Every unit has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been found or parts are missing please contact the manufacturer or your dealer for further instructions Do not return this unit to your dealer without first contacting FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING LED BLINDER 400 SAVE IT FOR FUTURE REFERENCE Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture PLEASE consider that damages caused by manual modifications to the device are not subject to warranty Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty In the unlikely event your unit may require service please contact the manufacturer or your dealer PLEASE recycle the shipping carton when ever possible General Instructions To optimize the performance of this product please rea
4. d these operating instructions carefully to familiarize you with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Features Multi Colors Sound Control Color Strobe LED operation menu with function Electronic Dimming 0 100 buttons DMX 512 protocol Daisy Chain Units Together in DMX Master Slave synchronization Mode Safety Precautions To reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Do not spill water or other liquids into or on to your unit Be sure that the local power outlet matches that of the required voltage for your unit Do not attempt to operate this unit if the power cord has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user serviceable parts inside Never operate this unit when it s cover is removed Never plug this unit in to a dimmer pack Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product outdo
5. e colored according to the following table The earth has to be connected If you have any doubts about proper installation consult a qualified electrician Core EU Core US Plug Terminal Marking Brown Live Light blue Neutral Yellow Green Earth DMX512 connection The fixture is equipped with 3 pin or 5 pin XLR sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 3 pin or 5 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another DMX output DMX input XLR mounting sockets rear view XLR mounting plugs rear view 1 Shield 1 Shield 2 Signal 2 Signal 3 Signal 3 Signal 4 Not connected 4 Not connected 5 Not connected 5 Not connected DMX Linking To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Operating Modes You can use the LED Blinder 400 in 4 ways Auto Mode The unit will automatically chase thr
6. ors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See Cleaning for details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance Set Up Power Supply Before plugging your unit in be sure the source voltage in your area matches the required voltage for your LED Blinder 400 The model is Auto power supply It is workable 90 250V 50 60Hz Please make sure your unit voltage matches the wall outlet voltage before attempting to operate you fixture Connection to the mains For protection from electric shock the fixture must be earthed Install a suitable plug on the power cord note that the cores in the power cord ar
7. ough the different colors and built in programs Slave Mode The unit will run under slave mode DMX control mode This function will allow you to control each individual fixtures traits with a standard DMX 512 controller Sound mode This function allows you to control fixture via sound DMX Mode Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs This function also allows you to use your fixtures as spot lights 1 This function will allow you to control each individual fixture s traits with a standard DMX 512 controller 2 The LED Blinder 400 uses 4 8 dmx channels to operate Please see DMX Values and Functions for the DMX traits 3 Torun your fixture in DMX mode plug in the fixture via the XLR connections to any standard DMX controller Set your desired DMX address following the setup specifications that come with your DMX controller Main Control Menu CONTROL BOARD The control board on the fixture base is your interface to access and control al functions on the unit Its digital display gives you a code vide of functions E m 0 MENU UP DOWN ENTER 8Chs Mode 4Chs Mode Fade Scroll Flash Scroll LED1 Intensity LED2 Intensity LED3 Intensity 001 512 001 512 00 99 00 99 000 255 000 255 000 255 LED4 Intensity Strobe Sound Dimmer 000 255 Dimmer Mode This function allows you to select dimmer mode Press Enter to use Up
8. t Weight 14 5Kgs Carton Package 1pcs master box Warranty 1 Year Note All information is subject to change without prior notice

Download Pdf Manuals

image

Related Search

Related Contents

Philips Remote control RC4703  Manual 6050  User`s Guide Guide d`Utilisation Guía del Usuario Guia do Usuário  HCD-GTR33/GTR55/GTR77  YS-S4 Multi Rotor Autopilot User Manual  GB Operating Instructions for Wall Clock »Chalet« F Mode d'emploi  Samsung Xpress C410W Farblaser Drucker (18 / 18 ppm) Benutzerhandbuch  Dodge 2004 Sprinter Cargo Automobile User Manual  

Copyright © All rights reserved.
Failed to retrieve file