Home
Invertek solar inverter 600-3000W user manual
Contents
1. 2 5 3 AC connection Before having AC connection match the power requirements of connected devices with the power output of pure sine wave inverter to avoid overload Consult a qualified electrician follow local code for the proper outlet connectors and select the correct outlet reference 2 3 3 AC outlet 3 Maintenance and troubleshooting 3 1 Preventative maintenance The following preventive maintenance routines should be considered as a minimum requirement Your installation and site may require additional preventive maintenance to assure optimal performance from your installed inverter and associated equipment These routines should be performed twice a year more often if required We strongly recommend a contract with pure sine wave inverter customer support services for preventive and remedial maintenance The technician or electrician performing preventive maintenance on the equipment must read and understand thoroughly this manual and be familiar with the indicators controls and operation of the equipment 3 2 Troubleshooting guide If the inverter fails to operate properly use the troubleshooting table to determine the probable cause s and solution s to resolve error conditions For unlisted error conditions please contact your local dealer for technical assistances Troubleshooting table 18 PDF sce EAS pdfFactory Pro TAABOAKGUEE www fineprint cn Invertek user s manual VO 02 Error condition Possible ca
2. WARNING Operation of the inverter without a proper ground connection may result in an electrical safety hazard Battery connector Connect the battery to the positive battery terminal and the negative battery terminal 2 5 Installation 2 5 1 Installation environment 15 PDF SEH pdfFactory Pro whHheAS a et www fineprint cn Invertek user s manual VO 02 The inverter should be installed in a location that meets the following requirements n Dry Do not allow water to drip or splash on the inverter n Safe Do not install in a battery compartment or other areas where flammable fumes may exist such as fuel storage areas or engine compartment n Ventilated Allow at least one inch of clearance around the inverter for air flow Ensure the ventilation opening on the rear and front of the unit are not obstructed n Dust Do not install the inverter in a dusty environments where are dust wood particles or other filings shavings are present Dust can be pulled into the unit when the cooling fan is operating n Close to batteries Avoid excessive cable lengths but do not install the inverter in the same compartment as batteries Also do not mount the inverter where it will be exposed to the gases produced by the battery These gases are very corrosive and prolonged exposure also will damage the inverter M6 screw T PVC WIRE AWG IT F 2 2 0 4 4 0 M Terminal Battery to inverter c
3. is given Then switch on the consumer again Reboot the inverter unit if the inverter can not work normally suggest to send the unit back to supplier Unit start failure DC AC circuit Reboot the inverter unit if the inverter can not work normally suggest to send the unit back to supplier Unit start failure DC DC circuit Reboot the inverter unit if the inverter can not work normally suggest to send the unit back to supplier Unit internal failure DC AC circuit 19 PDF cee EAD pdfFactory Pro TAUABOAGUEE www fineprint cn Invertek user s manual VO 02 No AC output and status LED is orange red blink red one times and yellow one time slow Audible alarm beep always No AC output and input level LED is red solid Audible alarm beep 1 time 1s No AC output and input level LED is orange solid Audible alarm beep 1 time 1s AC output exists and beep alarm 3 times per second 1 Check if output power cables are _ l connected to correctly Unit in parallel failure uu 2 Check if parallel communication cables are connected to correctly Input voltage lower than operating range 10 15V Ensure input voltage in 10V 15VDC range Input voltage higher than operating range 10 15V Reboot the inverter system if the inverter Fan failure can not work normally suggest to send the unit back to supplier 20 PDF cee EAI pdfFactory Pro TiAABOAGUEE www fineprint cn
4. 1j 108 el la Es le a a AAA ls 3000008600000808000064 NEMA 5 15R 2 position 1 IEC 2 position 1 Universal 2 hardwire B O O pr ao wA 0 D D 0 NEMA 5 15R 2 position 2 hardwire Australia New Zealand 2 UU hardwire 000099998800 Ao gt 0008868888088890860886 2 E Cave 2 E Qo00u8000 o e so Bess p g o n Ko tl eesooooo0000 See HI ee e le 000008000000006 000000660600 amp 00086300000350000080800000 s United Kingdom 2 hardwire a NEMA 5 20R 2 position 254 x PDF SARA E pdfFactory Pro TiAABOAGUEE www fineprint cn Invertek user s manual VO 02 2 4 Rear panel description and operation Main switch Remote control port Cooling fan Battery connector Ground terminal Rear panel view 1000W Main switch ON Located the switch to On the machine power on OFF Located the switch to OFF the machine power off REMO Located the switch to REMO the machine can be switched on or off remotely by wired remote control Remote control port Connect the remote control to the port Ground terminal Connect the GND to the ground terminal Please using 6 AWG wire to connect vehicle chassis
5. Invertek pure sine wave solar inverter 600 3000W User s manual PDF SEH pdfFactory Pro whHheAS Get www fi neprint cn Invertek user s manual VO 02 Contents Manual INS UNO a ME 3 Impornant Sen YSU CU ONS asa a ee is eee 3 POQUER TOUCIO E 5 11 General tUNcuo A descn 0 100 a 5 12258165 MMOGCIS IN OCU NO c amna LECT 7 19 AECC SIDS ING NO OR 7 1 4 Audible aldim eane nnn aeea oa 8 1 5 Environmental specifications 2m nn nnn E e 9 1 6 Fan CONOR aR nnnm nennen nnn nanan na nanan nana manna na nnm 9 1 7 Power limitation menn nnnm nnn nnn nnnm mee 9 10 SNOR CCU 0 C1611 0 LEE I EE 9 19 Werioad PE OLE cion A A A E A 10 2 Iristallauori and Opor aione al 10 2 1 Unpacking and inspection nc nn ncn cena nennen 10 2 2 Handling and Storage nnn nnn nn nnn ne nce nnn nnn ne enna manana mmMMmMMMMM 11 20 5 ONL Panel description dnd op ration AA 12 2 4 Hear Panel descripHor and operation o Apr nn ceeeae nop senseeates 15 ae OPAC S NANO RA ee AA 15 9 Mamtenance a a trouble snooHRg A o nce 18 OL Preventative Male NCAA oa 18 3 2 IMOUBIESIOOUING QUIE A 18 e PDF cee EAI pdfFactory Pro TiAHABOAGUEE www fineprint cn Invertek user s manual VO 02 Manual instruction Purpose The purpose of this manual is to provide explanations and procedures for
6. Use caution to reduce the risk or dropping a metal tool on the battery It could spark or short circuit the battery or other electrical parts and could cause an explosion o Remove all metal items like rings bracelets and watches when working batteries 6 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes f battery acid contacts skin or clothing wash immediately with soap and water If acid enters your eye immediately flood it with running cold water for at least twenty minutes and get medical attention immediately 8 If you need to remove a battery always remove the grounded terminal from the battery first Make sure all accessories are off so you don t cause a spark PDF sce EAI pdfFactory Pro TiAXABOGUEE www fineprint cn Invertek user s manual VO 02 1 Product introduction 1 1 General function description The pure sine wave inverter adopts many superior features and is designed based on the highest standards in the industry The advanced high frequency infrastructure with pure sine wave output is perfectly designed for diverse applications including home office and heavy duty industrial power environments The inverter can operate independently However the unique optional N X parallel redundancy structure design can maximize the expansibility of integrating additional units to the inverter system in the future Pure sine wave inverter promises to provide the extraordina
7. able connection 2 5 2 Battery connection 16 PDF cee EAI pdfFactory Pro TiAABOAGUEE www fineprint cn Invertek user s manual VO 02 Step 1 Following battery polarity guide located near battery terminal Place the battery cable ring terminal over inverter s battery terminal Tighten the M6 nut Do not place anything between the flat part of battery terminal and the battery cable ring terminal or overheating may occur Caution DO NOT place anything between battery cable ring terminals and battery terminals The terminal stud is not designed to carry current Apply anti oxidant paste to terminals after terminals have been torqued otep 2 Connect battery cables to your batteries Single battery connection when using a single battery its voltage must be equal to the voltage of pure sine wave inverter nominal input voltage Caution For the user operation safety we strongly recommend that you should isolate the battery terminals before you start to operate the unit If you parallel more batteries to extend the backup time please make sure that you already use tapes to isolate the rest battery terminals before you start to operating the unit Parallel battery connection when using multiple batteries in parallel each battery s voltage must be equal to the voltage of pure sine wave inverter nominal input voltage SAA UA 9 gt DC wiring connections Please be noted that connect the battery cables to the DC input term
8. e entertainment electronics television VCRs video games stereos musical instruments satellite equipment 1 2 Series models introduction PDF sce EAI pdfFactory Pro wHIWRA Gt www fineprint cn Invertek user s manual VO 02 To fulfill the diverse environments and power demands the pure sine wave inverter has complete lines for meeting the requirements from the clients The inverter system ranges from 600W to 3000W that can fulfill the majority power demands from home small business to industrial heavy duty environment 1 2 1 Product line 1 2 2 Physical specifications Weigh 270 L 160 W 70 H 425 L 245 W 95 H 495 L 245 W 95 H PDF cee ERI pdfFactory Pro wHIWRA Gt www fineprint cn Invertek user s manual VO 02 1000W dimension mm 42 392 ic UU Y 2000W dimension mm 49 462 JU RE fd 3000W dimension mm 1 2 3 Certification Safety Comply with EN60950 UL 458 Standard EMC FCC part 15 class B EN55022 Class B IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 1 3 Electrical specifications Nominal voltage 12VDC a Operating range 10VDC 15VDC Nominal output voltage 110 115 120VAC 220 230 240VAC Output frequency 50 60Hzx0 196 PDF cee EAI pdfFactory Pro TiAABOGUEE www fineprint cn Invertek user s manual VO 02 Output current 110 115 120 Output current 220 230 240 THD lt 3 linear load Peak output current Peak ou
9. ge If the inverter is going to be stored it should be stored in a cool dry well ventilated location where the rain splashing water chemical agents etc will not reach based on the environment specification standard The equipment should be covered with a tarpaulin or plastic wrapper to protect it from dust dirt paint or other materials aTi PDF 4I pdfFactory Pro WHW Gt www fineprint cn Invertek user s manual VO 02 The equipment can be lifted from the front panel by drawing out the handle Firstly screw off the steel bolt then drawing out the handle until the whole module out When the inverter module has to be installed in the shelf the bolt should be screwed down 2 3 Front panel description and operation Power saving Frequency setting LED indicator we AC OUTPUT I TERMINAL Com port 5 AC output outlet Parallel port Front panel view 1000W 2 3 1 LED indicator Refer to the above figure There are 3 dual color LED indicators on the front panel 1 Unit status indicator 2 Load level indicator 3 Input voltage indicator 1 Unit status indicator Blink fast Short circuit Orange and red interchanged slow Unit internal failure DC AC circuit Orange red LED Blink slow Unit internal failure DC DC circuit Orange and red interchanged fast Unit in parallel failure 2 Load level indicator 600W 0 30W 30 198W 198 450W 450 576W Over 576W D2 PDF SEH pdfFactory Pro wiHheAS Ge
10. inals of the pure sine wave inverter Your cables should be as short as possible ideally less than 6 feet 1 8 meters enough to handle the required current in accordance with the electrical codes or regulations application Cables are not an adequate gauge too narrow or too long will decrease the inverter performances such as poor surge capability and low input voltage warnings frequently and shutdowns If the cables longer or narrower the greater the voltage drop Increasing your DC cable size will help improve the situation The following cable recommendations are for the best performance of inverter apply both 120V and 220V versions le PDF ocfFBEH pdfFactory Pro WAIRERE www fineprint cn Invertek user s manual VO 02 Model P N Wire AWG Invertek600 120A Invertek1000 160A Invertek2000 2 0 320A Invertek3000 4 0 480A Warning 1 Connect the cables to the power input terminals on the rear panel of the inverter The red terminal is positive and black terminal is negative Insert the cables into the terminals and tighten screw to clamp the wires securely 2 Also use only high quality copper wire and keep cable length short a maximum of 3 6 feet Make sure all the DC connections are tight Loose connections could result overheat in a potential hazard 3 Carefully check that all wiring is disconnected from any electrical sources Do not connect the output terminals of the inverter to an incoming AC source
11. o add other more modules into the system achieve parallel function you can choose the propositional packaging if any missing or damage is discovered repack the unit and return it to the original place of purchasing Invertek pure sine wave solar inverter 600 3000 10 PDF ocfFBEH pdfFactory Pro TiAABOAGUEE www fineprint cn Invertek user s manual VO 02 Packing of inverter In addition some optional accessories are available could work with pure sine wave inverter Please base on your application and then choose the suitable package A necessary kit for the in parallel application It can make Sync hub 4 modules parallel and achieve synchronized operation Max in parallel ports 4 Used to connect the sync hub and inverter module oync cable 0 6M Cable length 0 6M Used for in parallel DC and AC power cords Terminal blocks 10P RS232 data line for communication between computer and Serial comm cable 1 8M inverter to monitor inverter s state and parameters setting Cable length 1 8M Designed for controlling the inverter unit remotely Cable length 10M Remote panel Accessories list table Standard package Package contents Sync hub 4 Sync cable 1 0 6M 4 pcs Package S1 Terminal blocks 10P Package S2 Serial comm cable 1 8M Remote panel 1 pc Sync hub 4 Sync cable 1 0 6M 4 pcs Package S3 Terminal blocks 10P Serial comm cable 1 8M 1 pc Remote panel Propositional packaging list 2 2 Handling and stora
12. operating maintaining and troubleshooting the pure sine wave inverter This manual should be read through carefully before installations and operations Please retain this manual for future reference Scope This document defines the functional requirements of pure sine wave inverter intended for worldwide use in electronic processing equipment The inverter unit shall contain a fan for forced air cooling The inverter may be used singly or in redundant configurations All manuals are applicable under all operating conditions when installed in the end use system unless otherwise stated Order of precedence This manual is intended for anyone who needs to install and operate the inverter In the event of a conflict between this manual and references cited herein this manual shall take precedence Organization This manual is composed of three chapters Chapter 1 product introduction contains the information about general description features and specifications of inverter Chapter 2 installation and operation provides the information about installation and operation of inverter Chapter 3 maintenance and troubleshooting contains the information of how to maintain and troubleshoot inverter Important safety instructions WARNING Before using the Inverter read and save the safety Instructions General safety precautions 1 Before installing and using the inverter read all instructions and cautionary markings on the inverte
13. r and all appropriate sections of this guide Be sure to read all instructions and cautionary markings for any equipment attached to this unit PDF cee ERY pdfFactory Pro AMARA www fineprint cn Invertek user s manual VO 02 2 his unit is designed for indoor use only Do not expose the inverter to rain snow or spray 3 To reduce risk of fire hazard do not cover or obstruct the ventilation openings Do not install the inverter in a zero clearance compartment 4 Use only attachments recommended or sold by the manufacturer Doing otherwise may result in a risk of fire electric shock or injury to persons 5 To avoid a risk of fire and electric shock make sure that existing wiring is in good condition and that wire is not undersized Do not operate the inverter module with damaged or substandard wiring 6 Do not operate the inverter module if it has received a sharp blow been dropped or otherwise damaged in any way Precautions when working with batteries To avoid personal injury and property damage read these battery precautions on handling charging and disposing batteries 1 Not reverse INPUT and INPUT to battery 2 Keeps the battery away from heat sources including direct sunlight open fires microwave ovens and high voltage container Temperatures over 60 C may cause damage Make sure the area around the battery is well ventilated 3 Never smoke or allow a spark or flame near the engine or batteries 4
14. ry performance in terms of reliability and flexibility all environments from home to heavy duty industrial 1 1 1 Features Adopts new pure sine wave inverter topology High power density with superior reliability and performance Surge rating 2 power rating Input output isolated design Optional N X redundancy function Design for harsh environment and various equipments All master dynamic mechanism eliminate single point failure to optimize reliability Pure sine wave output T HD lt 3 for wide range of applications and harsh environment Output frequency 50 60Hz switch selectable Low power power saving mode to conserve energy Capable of driving highly reactive amp capacitive loads at start moment LED indicators display Advanced DSP control Protection input low voltage overload short circuit low battery alarm input over voltage over lt We lt I We XL Wer We O Ws Ner X Ne Xe KXK temperature high output voltage low output voltage unit internal failure unit parallel failure 1 1 2 Application Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors Office equipment computers printers monitors facsimile machines scanner Household items vacuum cleaners fans fluorescent and incandescent lights shavers sewing machines Kitchen appliances coffee makers blenders ice markers toasters Industrial equipment metal halide lamp high pressure sodium lamp Hom
15. t is set as the normal value for inverter if output voltage is less than 40VAC and output current is higher than 2A for 4 cycles Inverter will judged as short circuit fault maybe happened and the short circuit protection algorithm will go to the second stage otage 2 unit resumed from short circuit condition The short current is regulated to 50 normal value if output voltage is less than 50VAC and output current is higher than 2A for 30 seconds the inverter system will consider the short circuit occurs and the short current is set to a small value 4A otherwise the short circuit alarm will be cleared 1 9 Over load protection Over load protection consists of 2 stages otage 1 The overload protection will happen if the load power exceeds the rated power With the conditions of 20s of 125 overload 10s of 15096 overload 5s of 200 overload the inverter system will judge as overload and de rate the output power less than the rated power Then the protection algorithm goes to the second stage otage 2 The inverter system remains operating with the de rating power If the load power is less than 1096 for 10s the system will recover back to the normal operation status 2 Installation and operation 2 1 Unpacking and inspection Once receiving your pure sine wave inverter remove the unit from its packaging and inspect it for scratches cracks broken connection Your purchase of inverter unit should ship with the manual If you want t
16. t www fineprint cn Invertek user s manual VO 02 1000W 0 50W 50 330W 330 750W 750 960W Over 960W 2000W 0 100W 100 660W 660 1500W 1500 1920W Over 1920W 3000W 0 150W 150 990W 990 2250W 2250 2880W Over 2880W 3 Input voltage indicator Battery cut off level 12VDC 2 3 2 Power saving frequency setting 1 Power saving mode can be set by 3 dip switches SW1 SW2 and SW3 on front panel For example when the power saving watt setting is 15W if load level215W the inverter will go to normal operation if load level lt 15W the inverter will go to the power saving mode SIT 20W 40W OFF OFF ow sow OFF OFF cow ew OFF BW 2 Frequency can be set by a dip switch SW4 on front panel LI PDF cee EAD pdfFactory Pro TAUABOAGUEE www fineprint cn Invertek user s manual VO 02 2 3 2 AC outlets AU poo 000 88000006 88000008 Q B pe88 0008800 pea8 0008830 J F E C zd ep D loD E E 62808000808080 to 0009980000 D 0000000000808080 0060008080000 De ul _ rs al a 005028 D3COJ00703c07035CBI0 al sm IMPZOZONIRSOIOCOCO l mO s gu ungaa 1 e a 8D wem SO Te HM i M JO HE e os g 00 C DOCOOZOL050CO02026C800 a TET S i quoe E eig E a e em pj zz An a i
17. tput current No load current draw Invertek600 1000 lt 6W Power saving recovery time 5 seconds Protection Overload short circuits reverse polarity Stand by current draw Over under input voltage over temperature Over under output voltage unit internal failure Unit in parallel failure 1 4 Audible alarm PDF cee EAI pdfFactory Pro iwWHIWRA GME www fineprint cn Invertek user s manual VO 02 1 Alarm Beep 1 time 1s Input level battery low level or battery high level Load 15096 Beep 2 time 1s Power limitation by temperature 1 5 Environmental specifications Operation temperature 20 C to 70 C Operating temperature 5 C to 40 C with full performance otorage temperature 30 C to 70 C Operating humidity 90 relative humidity no condense Operating attitude 1500M Load and temperature controlled cooling fan 1 6 Fan control 1 7 Power limitation Load Power limited curve Rated load 34 rated x oc M l rated Y rated A ridad 5 25 40 50 60 70 Temperature C Power de rating V S ambient temperature 1 8 Short circuit protection PDF cee ERI pdfFactory Pro TiAUHABOGUEE www fineprint cn Invertek user s manual VO 02 Short circuit protection algorithm consists of 2 stages Stage 1 power limited during short circuit The short curren
18. use Recommendation No AC output and all LEDs off No AC output and status LED is red blink fast No AC output and status LED is red blink slow Audible alarm beep always No AC output and status LED is red solid Audible alarm beep always No AC output and status LED is orange blink fast Audible alarm beep always No AC output and status LED is orange blink slow Audible alarm beep always No AC output and status LED is orange red blink red one time and Yellow one time slow Audible alarm beep always 1 Check if input cables are all firmly connected to power source 2 Check if power source is not yet switched on or is low in power 3 Check if input cables are connected to correct polarity positive to positive negative to negative reverse connect will lead to the fuse open need be repaired Lack of input power 1 Check if the devices connect to the AC output is damaged Short circuit Turn off the input power source remove the load and check the connection then switch on the input power to restart the inverter Reboot the inverter unit If the inverter can not work normally suggest to send the unit back to supplier Unit internal failure DC DC circuit 1 The inverter has been overheated switch off the inverter and the consumer and wait for approx 2 minutes and switch on the Over temperature inverter only suggest reduce the loading and make sure that a better ventilation for the inverter
Download Pdf Manuals
Related Search
Related Contents
Propellerhead Balance Mode d`emploi Sanyo PLC-XC50 data projector Belinea-1905S1 ODP 200 H-II - Support Technique AURES Procédure IMPR_RESU aux formats `RESULTAT` et Energy-Recovery Ventilation System Service Manual Bruciatori di gas ad aria soffiata Gas-Gebläsebrenner Three Hundred Two Manual de usuario Copyright © All rights reserved.