Home
User Manual - Title Boxing Equipment
Contents
1. Platinum Platinum Professional Fight amp Gym Timer User Manual Platinum Timer INSTALLATION Secure the Platinum Timer to the wall with two screws or wall anchors Before inserting the plug to the power point control that the data on the power supply plate is compatible with the plug in FUNCTIONING Platinum Timer is ideal to show the time of one or more cycles composed by an action followed by a pause and to signal with a sound of different length the various events start Action end Action end of the complete cycle 0 7 1 4 2 4 seconds The device is particularly indicated for competitions and training sessions in boxing martial arts gymnasium activities etc Five different timers can be programmed separately The timers are easily activated by five associated keys each one with the following four parameters Time of Action Time of Pause Number of Cycles Time of Final Pause Turning the Timer On and Off Turn on and off with the ON OFF key When turned off one separation point between the minutes and the seconds remain lighted up indicating the presence of the feeding current Visualizations If the time to be visualized is less than 10 00 it appears entirely on the right display and the number of cycles appear on the left display otherwise the minutes are visualized on the left display instead of the number of cycles Start and Stop of a Visualized Timer To begin the count of one of the five
2. Timers press the key of the desired Timer Timer x followed by the START STOP key When the key of this Timer is pressed twice the starting time is charged and visualized the START STOP key must then be pressed to begin the count The time count can be stopped and then started again with the START STOP key Timer Booking A Timer can be booked in order to start a count automatically at the end of a Timer that is visualized If the Timer in use is programmed on an infinite cycle the booked Timer will begin at the end of the first pause of the working Timer To make a booking press the key of the Timer x to be booked and then the Timer Booking key Start and Stop of a Blind Timer It is possible to activate any one of the five Timers so that they only issue the audio signals of start end of the various cycles without being visualized press the key of the Timer x chosen and then the Blind Timer START STOP key The time count can be stopped and then restarted with the same key Since the count of the Blind Timer works with different sounds it can function contemporaneously with the Visualized Timer without the risk of creating confusion this allows to time 2 activities simultaneous ly in the same place such as a meeting be tween two boxers and training exercizes performed by other athletes Timers Status With the Timers status key the number of active Timers are visualized for 4 seconds seeFig 1 the timer inuse
3. ction Modification of the value is regulated as for parameter xA xC Number of Cycles or Rounds from 0 99 This parameter defines the number of cycles by Action Pause with xD 0 the number of cycles is infinite and they can be interrupted only by the START STOP key Modify the value with the keys and press continuously to vary quickly xF Time of Final Pause or Stop from 0 00 to 90 00 This parameter sets the Final pause that follows the last Action After the Final pause the entire cycle is repeated with xF 0 the Final pause does not occur and the cycle is performed only once Modification of the value is regulated as for parameter xA EXAMPLES OF PROGRAMMING Following are several examples of how each of the 5 Timers can be programmed to obtain different modalities of functioning Single Action Indicated for visualizing the time of a competition with the final audio signal To program xA Time of Action xP 0 xC 1 and xF 0 Fixed Number of Cycles Indicated for visualizing the time of competitions repeated on various occasions To program xA Time of Action xP Time of Pause xC Number of cycles xF 0 Infinite Number of Cycles Indicated for continuous sequences of training it can be interrupted only by press ing the START STOP key To program xA Time of Action xP Time of Pause xC 0 xF 0 Sequences with a Fixed Number of Cycles and Final Pause Indicated for training sequences with rec
4. eys and select 3 for High 2 for Medium 1 for Low 0 for Off Press PROG to pass onto the follow ing parameter or START STOP to end the pro gramming PROGRAMMING THE TIMERS For each one of the 5 Timers there are 4 programming parameters for a total of 20 pa rameters Each one is identified by the number of the timer 1 2 3 4 5 and by the letter of the parameter A P C F for Timer 1 1A 1P 1C 1F for Timer 2 2A 2P 2C 2F for Timer 3 3A 3P 3C 3F for Timer 4 4A 4P 4C 4F for Timer 5 5A 5P 5C 5F These 20 parameters can be accessed with the PROG key and can be modified with the and keys Immediate access to the first parameter xA of the chosen Timer occurs by pressing PROG and then the desired Timer x key Programming is terminated with the START STOP key The 4 parameters A P C F concerning the 5 Timers x are described as follows xA Time of Action from 0 05 to 90 00 Modify the value with the keys and press continuously to vary quickly There are time steps of 1 second for values from 0 05 to 1 00 time steps of 5 seconds for values from 1 00 to 10 00 time steps of 1 min ute for values from 10 00 to 90 00 Please note that for over 10 minutes the seconds are no longer visualized 2 xP Time of Pause or Reset from 0 00 to 90 00 Determines the Time of Pause fol lowing the A
5. is indicatedwitha flashing number whereas inactive timers 1 User Manual are indicated with fixed lighting If the F1 key is pressed within 4 seconds the Visualized Timer and the Blind functions will be ex changed in this way it is possible to visual ize the Timer that was only present through a sound signal With F2 instead of F1 the pos sible booking will be deleted PROGRAMMING Press the PROG key t o access programming H1 will appear on the left display indicating the first parameter to be programmed and on the right display the respective value will appear which can be modified with the keys and Press PROG once again to pass to the following parameters or START STOP to end the programming H1 Counting Modality forward backward up do This modality defines the direction of the count With the keys and select up for forward counting or do for back ward counting Press PROG to pass to the fol lowing parameter or START STOP to end the programming H2 Type of Sound Trilling or Continuous 1 2 This modality defines the sound type of start end for the various times With the keys and select 1 for a trilling sound and 2 for a continuous sound Press PROG to pass onto the following param eter or START STOP to end the programming H3 Sound Volume High Medium Low Off 3 2 1 0 This modality defines the sound intensity with the k
6. ov ery times pause of differing duration After the Final Pause the entire cycle is repeated it can be interrupted only by pressing the START STOP key To program xA Time of Ac tion xP Time of Pause xC Number of cy cles xF Time of Final Pause Combination of Two Timers The activation of a Timer and the booking of another timer allows to considerably increase the combinations of the time count For ex ample among the many possibilities the count of a certain number of cycles of Action Pause may be performed followed by a different number of cycles with different durations ofAction Pause see Fig 2 REMOTE CONTROL The remote control allows the user to control without cables all of the functions for a dis tance of up to 50 feet The Platinum Timer can be used with or without the remote con trol 3 WARRANTY The Platinum Timer is guaranteed for 2 years from the date of purchase and includes re pairs for material and construction defects Transport costs are not included Battery is excluded from the warranty Warranty does not cover dropped or damaged timers Please make sure the timer sets or hangs on a sturdy and secure surface 4
Download Pdf Manuals
Related Search
Related Contents
Tripp Lite SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD USER MANUAL - Fleet Line Markers Programme Jeune public - Festival Cinéma d`Alès LGS-1012P 液晶プロジェクター VA series - DAS Audio PLC-XU116 Ultra Portable Multimedia Projector Copyright © All rights reserved.