Carbon Monoxide Meter TM-801 / TM-802
Contents
1. 1000 counts 60mm W x 47mm L monochrome LCD and backlight Sample rate 1 times second Dimension 156x73x35mm LxWxH Weight approx 250g Batteries not included W Power Supply UM 4 AAA 1 5Vx 6 PCS or AC100 240V DC9V 0 5A 9mm Adaptor W Battery life approx 90 hours W Operating Temperature amp Humidity 20 C to 50 gt 8096 W Storage Temperature amp Humidity 10 C to 50 gt lt 70 RH W Data output USB PC serial interface W Standard Accessories UM 4 AAA 1 5V battery x6 PCS User s manual gt USB cable TM 802 AC100 240V DC9V 0 5A 9mm x1 TM 802 Install CD disk TM 802 WARNING To ensure that the accuracy of the meter We recommend for calibration once a month TENMARS This test was designed in accordance with EMC Standards in force and its compatibility has been tested in accordance with EN61326 1 2006 TM 801 TM 802 4 CO LEVELS AND STANDARDS Carbon monoxide content in the air Inspiration time Symptoms and applicable standard 0 1 ppm Normal background levels 9 ppm Maximum indoor air quality level 35 ppm 8 hours The average exposure level per U S OSHA workplace standards 50 ppm 8 hours The maximum average exposure of the U S OSHA workplace standards 0 01 100 ppm 2 3 hours evacuate people from enclosed space if the CO concentration exceeds 100 ppm per OSHA expos
2. EI 114 TAIWAN E mail service tenmars com http www tenmars com
3. Max Socket Pin positive Ground casing negative External Diameter 5 5mm Internal Diameter 2 1mm 21 SAFETY AND MAINTENANCE STANDARDS e Donot put this device in direct sunlight or where it is hot and or damp Operating altitude below 2 000 TENMARS TM 801 TM 802 22 BATTERY REPLACEMENT If the LCD displays symbol please replace the battery immediately Turn off the power and unplug all cables remove the battery and replace into the new battery Please use the correct specification of the battery and correctly installed in the battery holder 23 END OF LIFE Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection pamm and correct disposal If not using the meter please remove the battery to avoid possible damage p 2 TENMARS lt 15 gt Professional Electrical and Environment Test amp Measurement Instruments Battery Capacity Impedance Tester LED light meter Temperature amp Humidity meter Infrared Thermometer Sound level meter Light meter EMF meter UV Light meter RF meter Hot wire Anemometer CO meter Anemometer Lan cable tester CO2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation test Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIP
4. TENMARS Carbon Monoxide Meter TM 801 TM 802 User s Manual TENMARS TM 801 CO Meter Temp 2 8010002 TENMARS ELECTRONICS CO LTD an Cou eec XOT Qo cO QU POI oe TABLE OF CONTENTS 1 GENERAL 1 TECHNICAL SPECIFICATIONS 2 CO LEVELS AND STANDARBDS 4 INSTRUMENT DESCRIPTION 6 LCD 7 POWER ON OFF ive econtra 8 AUTO POWER 8 BACKLIGHT 8 CHANGE THE TEMP 8 DATA HOLD 9 CO ALARM 9 MAXIMUM MINIMUM AVERAGE 10 CHANGE SETL TWA TM 802 10 REC SETTING TM 802 10 CALIBRATION 2 11 PRECAUTIONS eese 13 SOFTWARE INSTALLATION TM 802 13 COMPUTER GRADE 13 EXTERNAL DC POWER 14 SAFETY AND MAINTENANCE STANDARDS 14 BATTERY 15 END OF LIFE 15 TENMARS TM 801 TM 802 1 PREFACE Thank you for purchasing our product Please read the operating instructions
5. UM MINIMUM AVERAGE Press button simultaneously Lockup data maximum and minimum and average value of measuring data Press the button for more than 2 seconds to disable this feature 14 CHANGE SETL OR TWA TM 802 Press button to change SETL or TWA values X SETL Short Term Exposure Limit 15min short term max X TWA Time Weighted Average 8 hours average 15 REC SETTING TM 802 Enter logger setting mode button for times to enter into Press the record setting mode the SET and INTV will display on the LCD Logger Storage interval setting Press C button button to set logger storage interval hh mm press 10 TENMARS TM 801 TM 802 button to exit the logger storage interval setting mode The Down left LCD will display L on or L oF Logger enable disable setting SEL Press button to enable or disable logger L on or L oF press button to exit logger setting Start logging if logger mode is on the will blink on LCD if the data is downloaded the tl will blink on the LCD 16 CALIBRATION Please shutting down the meter first then hold and press MoE button and press button to enter into calibration mode It will show a blinking O ppm on the upper display and the lower left corner of the screen will display the value of the ADC 11 TENMARS TM 801 TM 802 In the calibration must away from the environment or equipmen
6. ess 9 button to turn on or turn off the meter It will be unable to turn off under setting up alarm and correction 8 AUTO POWER OFF The duration of auto power off time is 15 minutes If you want disable auto power off please hold button and press 2 button at the power shutdown mode When you see the n SL display on the LCD that means the auto power off function is off If you want enable auto power off please restart the meter The auto power off will disable if the alarm is enabled 9 BACKLIGHT Press 8 button to turn on the backlight press this button again to turn it off The backlight time is 15 seconds 10 CHANGE THE TEMP UNIT Press 58 button to change the temperature F unit TENMARS TM 801 TM 802 11 DATA HOLD Freezes the reading present on the LCD screen at the moment the button is pressed 12 CO ALARM SETTING Hold and press button for more than 2 seconds to enter into the alarm setting mode SEL press button to choose and press button to turn on A on or turn off A oF the alarm If you select the alarm to be turned on A on press 8 button to select alarm value 25 50 100 250 400 800 0000 and press button to enable If you select the 0000 press button button to enable Hold and press button to High value adjustment the highest setting value is 1200 and the lowest is O to adjust the value and press TENMARS TM 801 TM 802 13 MAXIM
7. in details before you use this CO meter so you will operate the meter correctly This meter can be operated in industry and home Non compliance warning and or operating instructions may damage the instrument or its parts or injuring the operator 2 GENERAL DESCRIPTION W Adjustable alarm Adjustable alarm threshold level 25 35 50 100 250 400 800 Randomly Adjustable Enable Disable alarm Dual and digital display of the CO and temperature measuring Maximum Minimum Average hold Data hold HOLD Low battery indication LED Backlight Auto power OFF and disable function USB PC Interface TM 802 Data logging capacity up to 8000 1 TENMARS TM 801 TM 802 reading TM 802 Choose the recording interval TM 802 3 TECHNICAL SPECIFICATIONS 3 1 Characteristics Accuracy is indicated as V6 of reading ppm It is referred to the following reference conditions 23 C 5 C with RH 7595 CO Carbon monoxide Range 0 1000ppm Resolution 1 5 2 Repeatability lt 2 Response time 30 seconds Zero drift in long term lt 5 Sensitivity drift lt 5 per year Typical sensor life 3 years The response time refers to the fixed value of 9096 of the value Temperature Range 20 50 C 4 122 F Resolution 0 1 C 0 1 F Accuracy 1 0 C 1 8 F TENMARS TM 801 TM 802 3 2 General data W 4dgt LCD with maximum
8. t with electromagnetic waves 0 ppm Calibration The meter is running 0 ppm calibration as default Put the meter in an area free of CO and enter the calibration mode It calibrates automatically The duration of calibration time is 5 minutes 100 ppm 500 ppm Calibration After end of the 0 ppm calibration the screen will display 100 ppm then press 2 button to select 100 ppm or 500 ppm value button to start calibration It and press will show a blinking 100 ppm or 500 ppm on the upper display and the lower left corner of the screen will display the value of the ADC and place the meter into the sealed box filled with standard gas e g 100 ppm 500 ppm for 5 minutes then the calibration will be done automatically 12 TENMARS TM 801 TM 802 X Check if the reading meets calibration value If it does the calibration is not repeat the procedure 17 PRECAUTIONS Keep the meter away from electromagnetic interference EMI which may cause erratic readings Recovering time is required when meter exposed to high level CO The longer the exposure the longer recovering time is needed 18 SOFTWARE INSTALLATION TM 802 Please refer to the TM 802 installation CD execution 19 COMPUTER GRADE CPU Pentium III 1000MHZ RAM SDRAM 256MB HARD DISK 200MB OS Windows 2000 Windows XP DISPLAY 800x600 256 color TENMARS TM 801 TM 802 20 EXTERNAL DC POWER External AC to DC adapter Voltage 9 Vpc 8 14 Vpc
9. ure limit Mild headache 0 04 400 ppm 1 2 hours Headache occur in 2 5 hours to 3 5 hours 0 08 800 ppm 45 min Dizziness nausea cramps convulsions 0 16 1600 ppm 20 min Headache dizziness and will be dead within 2 hours TENMARS 801 802 Headache dizziness 0 32 3200 ppm 5 10 min vomiting and will be dead in 30 minutes Headache dizziness and 0 6496 6400 ppm 1 2 min will be dead within 10 to 15 minutes 1 2896 12800 ppm 1 3 min Will die TENMARS TM 801 TM 802 5 INSTRUMENT DESCRIPTION 1 HOLD Button 10 CO SENSOR 2 Power Button 11 USB 3 MAX MIN AVG 12 DC POWER Button 4 MODE Button 13 HOLDER 5 Backlight Button 14 Battery Holder 6 SEL Button 15 Battery Cover 7 LCD 8 Temperature Sensor 9 Earphone Jack TENMARS TM 801 TM 802 6 LCD DESCRIPTION 9 2 2 0 SET HOLD REC AVG STEL TW HI 11 2844 SET symbol HOLD symbol REC symbol MAX symbol MIN symbol AVG symbol STEL symbol TWA symbol Numeral reading value 10 PPM unit 11 Temperature unit 12 Temperature Reading 13 Reading symbol 14 Memory symbol 15 Alarm symbol 16 Time constant symbol 17 Interval symbol 18 Time display 19 Auto power off 20 CO symbol 21 Low Battery symbol TENMARS TM 801 TM 802 7 POWER ON OFF Pr
Download Pdf Manuals
Related Search
Related Contents
Intel ECB-862 User's Manual manuale DIFFUSIONE BIG.pmd VBrick Systems MPEG-1 User's Manual Sandisk Memory Stick PRO Duo™ 4GB New Registration - Office of Company Registrar Sun Netra CP3240 Advanced Mezzanine Card LED Userճ Guide Bio-Dot® SF Microfiltration Apparatus Instruction Manual CONTROL UNIT E6LDC FOR FIRE DOORS WITH ONE DRIVE UNIT Copyright © All rights reserved.