Home

Grain moisture Schaller

image

Contents

1. 5 up to 50 depending on the material 0 C up to 40 C 20 C up to 60 C Automatically 4 pcs 1 5Volt AA Alkaline batteries 1800 measurements After app 6 minutes adjustable 55 mA with light 128 x 64 matrix display lighted 260 x 70 x 250 mm app 1 3 kg with batteries IP 40 Plastic case Digital scale 1000g Measuring cup 0 5 litre 4x 1 5Volt AA Alkaline Batteries software LogMemorizer
2. User manual short version P Grain special fruit moisture meter humimeter FS4 E sem La S STEP Systems GmbH al Gan Em rou Pratiessiuriil Gysen Duisburger Str 44 D 90451 Numberg Systems H E S Tel GO49 05 911 96 26 05 0 Fax 00d 05 911 36 26 05 9 e Mail infatistepsystems de Internet www stepsystems de User manual short version 1 Place the empty provided cup 0 5 litre on the scale and turn the scale on It shows 0 0 gram 2 Fill up the cup with the sample material 1 0g The fill quantity is shown on the upper left corner on the display of the humimeter FS4 3 Make sure that the measuring chamber is completely empty It is important that no e material is left in the measuring chamber when you turn on the device 4 Switch on the humimeter FS4 by pressing the power button OO for 3 sec 5 As the next step please do the self calibration The word calibrate will show up on your display Accept by pressing the button 6 In case a menu point is shown press the left button W until you reach the measuring window 7 Select the right calibration curve for your material under test using the buttons A or 8 Fill up the measuring device with the sample material The filling needs to be done slowly and constantly to ensure reproducible results 9 The display shows the measuring result 10 To save the results in the stor me
3. nu press the nl A button The storage g was successful when the number mr front of the symbol KW increased To reach the store menu please press Ge until the dl appears 11 To name the saved results press the button 12 Empty the humimeter and ensure that no grain rests are accumulated in the measuring chamber Calibration curves Name of Calibration Material under test Fill quantity curve 200g corn hand tegen mm mmm me mme mee mm amog Wwheaispe ne wheat speltpesied mm mere barey mm mes om mm wm me 8008 Zig pumpkin pumpkin seed mm mes peas f og 300g soybean soybean 300g 295g horse bean horse bean 295g a0grice pesed vricepeeled mp 2B5grawcotpee vraw coffee peeled 2859 180g coffee kib coffee kibbled mm teng coffeeroa coffee roastet mm 300g poppy poppy mm mme e e gt Reference To test the humimeter FS4 Do not use for measuring the moisture gt There are another 10 empty calibration curves stored in the measurement device These can be used from the customers for special fruits or variety calibration Menu There are 4 menu levels The symbols show the key functions in the different menus 1 Type Selection 2 Store Menu 3 Additional level 4 Main menu Edit Logs Manual Logs Clear Logs Print Logs Last Log All Logs Clear Send Logs Manual Logs Clear Logs Options Date Time Log Time Language Unlock GOAT G boy G D Ke
4. of as the batterie cap und pull it back 2 Remove the empty batteries 3 Put four new batteries in the device Make sure the position of the battery poles is correct 4 Press down the batteries and close the Cap Determination of the material moisture The principle is a comparison measurement with the drying out method according to DIN 103850 1967 09 Take the measured sample and weigh it Dry it out in an oven and weigh it again Following formula can be taken to determine the absolute moisture Note The dried material may not be used any more for measuring purposes Mn Mt X Mn F 100 Mn Mass with average moisture content M Mass of the dried sample F Calculated absolute moisture Exemption from liability For miss readings and wrong measurements and of this resulting damage we refuse any liability This is a device for quick determination of moisture The moisture depends on multiple conditions and multiple materials Therefore we recommend a plausibility check of the measuring results Each device includes a serial number and the guarantee stamp If those are broken no claims for guarantee can be made Technical data Resolution of the display Measuring range Operation temperature Storage temperature Temperature compensation Power supply Auto Switch OFF Current consumption Display Dimensions Weight Degree of protection Scope of supply 0 1 water content 0 5 C temperature
5. ypad symbols Measuring window Rolling Menu Power ON OFF Switch upper Switch lower Save Hold Watch the measuring rows gt gontren Suppliers data can be added 4 Enter A Switch upper F Switch lower Exit 0 9 Enter numbers DS Enter letters Ke Next or right vi Left af Yes A No de Shift OK OK Design of the device Name of calibration curve Filler assistance Measuring chamber POWER button Batteries slot flipside Most common reasons for miss readings e Product temperature out of application range Material below 0 C resp above 40 C 82 to 104 F may causes faulty measurements The storage of cold material in a warm storage area usually creates condensed water which may lead to major measuring errors e Not adjusted material Let your humimeter FS4 adjust to the surrounding temperature of the material for approx half an hour A very high temperature difference has a negative effect on the stability of the measurement result IMPORTANT please read e Wrong calibration curve Before you measure your sample doublecheck the correct selection of the calibration curve e Wrong fill quantity Fill exactly the right weight 1 0 g in the measuring chamber e Wet or mouldy material e Frozen measuring material Changing batteries Your new device is provided with batteries Changes the batteries 1 Press with your finger onto the arrow

Download Pdf Manuals

image

Related Search

Related Contents

844R_3Ph_multi_rev B  Selección de una emisora de radio  

Copyright © All rights reserved.
Failed to retrieve file