Home
Power Supplies
Contents
1. class 4 EN61000 4 1 1 Storage 40 to 85 C Operation 25 to 60 C full power with linear derating to half power from 60 to 70 C Convection cooling no forced air Temperature required Operation up to 50 load permissible with sideways or front side up mounting orientation Humidity lt 90 RH noncondensing IEC 60068 2 2 68 2 3 Immunity O to 3000 meters O to 10 000 feet 2 5 g RMS 10 2000 Hz random three axes for 20 minutes each IEC 60068 2 6 3 g peak three axes 11mseconds for each axis IEC 60068 2 27 5 Year Limited Warranty MTBF gt 500 000 hrs MTBF Nominal voltage full load Tre 25 C G Protection Safet Protected against short circuit overload open circuit Protection class 1 IEC536 degree of protection IP20 IEC 529 eneral Frotection satety Safe low voltage SELV acc EN60950 Over temperature protection LED Alarm Output shutdown with automatic restart Status Indicators Visual 3 status LEDs Input Output Alarm Relay SSR or dry relay contact signal active when Vu 18 5 Vdc 5 Installation Externally fused Not fused Output is capable of providing high currents PowerBoost for motor load startup Simple snap on to DIN TS35 7 5 or TS35 15 rail system Unit should handle normal shock and vibration of industrial use and transportation without falling off the rail Input screw terminals Wiring for the connector will be Ground on the left when looking at the front of the
2. derating to half power from 60 to 70 C Convection cooling emperane no forced air required Operation up to 50 load permissible with sideways or front side up mounting orientation MTBF gt 450 000 hrs gt 500 000 hours demonstrated 5 Year Limited Warranty Protected against continuous short circuit continuous overload continuous open circuit Protection Class 1 IEC536 degree of protection IP20 EN61000 6 1 2001 EN61000 6 2 2001 EN61000 4 2 Level 4 EN61000 4 3 Level 3 EN61000 4 6 Level 3 EN61000 4 4 Level 4 input and level 3 output EN61000 4 5 Isolation class 4 EN61000 4 11 IEC 61000 4 34 voltage dip immunity standard General Protection Safety IEC60529 Safe low voltage SELV acc IEC60950 1 Visual 3 status LEDs Input Output Alarm Status Indicators Relay N O contact rated 200ma 50 Vdc Installation Fusing input internally fused Outputs are capable of providing high currents for short periods of time for inductive load startup or switching Fusing may be required for wire loads if 2x Nominal O P current rating cannot be tolerated Continuous current overload allows for reliable fuse tripping Mounting Simple snap on to DIN TS35 7 5 or TS35 15 rail system Input Screw terminals connector size range 16 10 AWG 1 5 6 mm Input Screw terminals connector size range 16 10 AWG for solid conductors Screw Torque 4 4 Ib in 50 N cm 1 5 6 mm for solid conductors Screw
3. 9 67 aT Nominal Voltage 24 V 23 5 28 5 Vdc Adj lt 2 overall combination Line load time and temperature related changes Initial Voltage Setting 24 5 V 1 e 5 lt 100 mVpp lt 100 mVpp PARDO sis PARD Periodic and Random Deviation 100 mV peak peak max Short Circuit Current 1 5 x Nominal Current at near zero volts at short circuit condition 1 8 x Nominal Current at or near zero volts at short circuit condition Current Limit Switch selectable single unit or parallel unit operation Units will not be l 1 7 Parallel Operation damaged by parallel operation regardless of switch position setting PCIE arallenng Holdup Time gt 20 mS Full load 100 Vac Input T _ 25 C to 95 output voltage Voltage Fall Time lt 150 mS from 95 to 10 rated voltage full load T _ 25 C Line and Load Regulation lt 0 5 EN61000 6 2 2001 EN61000 6 3 2001 Class B EN55011 EN55022 EN61000 6 3 EN61000 6 4 Class B EN55011 EN55022 Radiated and Conducted including Annex A EN61000 3 2 Radiated and Conducted including Annex A EN61000 3 2 EN61000 3 3 EN61000 6 1 EN61000 6 2 EN61000 4 2 Level 4 EN61000 4 3 Level 3 EN61000 4 4 Level 4 input and Level 3 output EN61000 4 5 Installation Class 4 EN61000 4 6 Level 3 EN61000 4 8 EN61000 4 11 SEMI F47 Sag Immunity Transient protection according to VDE 0160 W2 over entire load range T ture Storage 40 C to 85 C Operation 25 C to 60 C full power with linear
4. SOLAD Power Supplies 3 SDN C Compact DIN Rail Series The SDN C DIN rail power supplies are the next generation of the popular SDN series These models combine high efficiency and compact size with new visual diagnostic LEDs to offer the most performance available from SolaHD Essential industrial features such as Sag Immunity Power Factor Correction and universal voltage input have been retained in this series Wide temperature operating range and parallel operation capability make the new SDN C units suitable to a variety of industrial applications Applications e Industrial Machine Control and Process Control e Conveying Equipment e Material Handling e Vending Machines e Packaging Equipment and Amusement Park Equipment e Semiconductor Fabrication Equipment e DeviceNet Features e Compact packaging to save space on the DIN rail e Visual diagnostic LEDs for input and output status at a glance e High MTBF means high reliability and long life e Higher efficiency saves energy and lowers amount of heat generated in panel e PowerBoost overload capability to start high Inrush loads e Accepts Universal voltage 85 264 Vac 50 60 Hz input e Active Power Factor Correction e Patented DIN rail mounting clip e User Adjustable output voltage accessible via front face e Parallel capability standard e Large rugged accessible screw terminals e Industrial grade design 25 C to 60 C operation without derating e Fully teste
5. Torque 4 4 Ib inch 50 N cm i 10 Connections Output Two terminals per output connector size range 16 10 AWG Output Two terminals per output connector size range 10 6 AWG 1 5 6 mm for solid conductors Screw Torque 7 lb inch 80 N cm 6 14 mm for solid conductors Screw Torque 15 6 lb inch 176 N cm Gase Fully enclosed metal housing with fine ventilation grid to keep out small parts 25 40 mm above and below 10 mm left and right 15 mm in front HxWxD inches in mm 4 85 x 3 42 x 4 98 123 0 x 87 0 x 127 0 4 85 x 7 09 x 4 81 123 0 x 180 0 x 122 0 Weight Ibs kg 2 6 1 20 6 0 2 75 Not UL listed for DC input 6 Peak current is calculated at 24 Volt levels Input Current ratings are conservatively specified with low input worst case 7 All models except the 40amp unit are capable of parallel operation by use of a efficiency and power factor jumper pin accessible by the end user 40 amp unit will have active current sharing 3 Losses are heat dissipation in watts at full load nominal input line signal 4 24 28 Vdc adjustable guaranteed at full load 8 Contact tech support for operation at 25 C 5 Ripple noise is stated as typical values when measured with a 20 MHz bandwidth 9 Demonstrated through extended life test scope and 50 Ohm resistor 10 SDN 40 24 100C only Output signaling terminal block features Shut down Power Good Current Monitor Current Balance signal GND 120 Contac
6. d and burned in at factory e Highly efficient switching technology e Five year limited warranty Certifications and Compliances All Models c s Listed Ind Control Equipment E61379 UL 508 CSA C22 2 No 107 1 Ge Aus CE p E61379 E137632 E234790 e CA us UL Recognized Component ITE E137632 UL 60950 1 CSA C22 2 No 60950 1 2nd Edition CE Low Voltage Directive IEC EN60950 1 2nd Edition e Sag Immunity SEMI F47 e RoHS Compliant Models SDN 20 24 100C SDN 20 24 480CC SDN 40 24 480C CAd us UL Recognized Component Haz Loc E234790 ISA 12 12 01 CSA C22 2 No 213 Class Division 2 Groups A B C D Models SDN 5 24 100C SDN 10 24 100C SDN 40 24 1000 SDN 5 24 480C SDN 10 24 480C CAd us UL Recognized Component Haz Loc E234790 UL 60079 15 CSA E60079 15 Class I Zone 2 AEx nC IIC Ex nC IIC e x ATEX Directive EN60079 0 EN60079 15 113 G Ex nC IIC Go Related Products e SDN P series e SDP series e SCP series e SDU UPS Accessories e Chassis Mount Bracket SDN PMBRkK2 Refer to user manual for installation requirements when used in hazardous locations Contact Technical Services at 800 377 4384 with any questions 117 Visit our website at www solahd com Power Supplies SOLAH D The SolaHD Difference Rugged metal housing Multiple output connections for ease of wiring multiple devices Large IP20 rated screw terminals f
7. ds if 2x Nominal O P current rating cannot be tolerated Continuous current overload allows for reliable fuse tripping Simple snap on to DIN TS35 7 5 or TS35 15 rail system O AW ON crew terminals connector size range Output Two terminals per output connector size range 16 10 AWG 1 5 6 mm for solid conductors Screw torque 7 lb inch 80 N cm Fully enclosed metal housing with fine ventilation grid to keep out small parts 25 mm above and below 10 mm left and right 15 mm in front 4 85 x 1 97 x 4 36 4 85 x 2 36 x 4 36 123 0 x 50 0 x 110 0 123 0 x 60 0 x 110 0 17 0 80 1 Not UL listed for DC input 5 Ripple noise is stated as typical values when measured with a 20 MHz bandwidth 2 Input current ratings are conservatively specified with low input worst case scope and 50 Ohm resistor efficiency and power factor 6 Peak current is calculated at 24 Volt levels 3 Losses are heat dissipation in watts at full load nominal input line 7 Contact tech support for operation at 25 C 4 24 28 Vdc adjustable guaranteed at full load 8 Demonstrated through extended life test Contact Technical Services at 800 377 4384 with any questions 119 Visit our website at www solahd com 3 Power Supplies SO ALH D SDN C Specifications Single Phase SDN 20 24 100C SDN 40 24 100C a Nominal Voltage 115 230 Vac AC Range 85 264 Vac DC Range 90 375 Vdc Frequency 43 67 Hz Eeer T T T S E T 2
8. n Units will not be damaged by parallel operation regardless of switch position setting gt 20 ms Full load 100 Vac Input T 25 C to 95 output voltage lt 150 mS from 95 to 10 rated voltage full load T m 25 C EN61000 6 2 2001 EN61000 6 3 2001 Class B EN55011 EN55022 Radiated and Conducted including Annex A EN61000 3 2 EN61000 6 1 2001 EN61000 6 2 2001 EN61000 4 2 Level 4 EN61000 4 3 Level 3 EN61000 4 6 Level 3 EN61000 4 4 Level 4 input and level 3 output EN61000 4 5 Isolation class 4 EN61000 4 11 IEC 61000 4 34 voltage dip immunity standard Storage 40 C to 85 C Operation 25 C to 60 C full power with linear derating to half power from 60 to 70 C Convection cooling no Temperature forced air required Operation up to 50 load permissible with sideways or front side up mounting orientation MTBF gt 550 000 hrs Warranty 5 Year Limited Warranty General Protection Protected against continuous short circuit continuous overload continuous open circuit Safety Immunity Protection Class 1 IEC536 degree of protection IP20 IEC60529 Safe low voltage SELV acc IEC60950 1 i Visual 3 status LEDs Input Output Alarm Status Indicators Relay N O contact rated 200ma 50 Vdc Installation Internally fused Outputs are capable of providing high currents for short periods of time for inductive load startup or switching Fusing may be required for wire loa
9. or 10 AWG 6 mm for quick easy installation Visual diagnostic LEDs show inout and output status see table below DC OK Relay Single or parallel use selectable by user Adjustable output voltage Clearly labeled front panel Pi EL ne No internal fan no extra cooling E of rt required in any power level Multiple certifications for versatility in applications IND CONT EQ SHAD C cl US LISTED 115 230V 2 2 1 04 50 60 HZ Automatically adjusts for global N L Input voltages No manual a intervention required EJL ET C Narrow width saves panel space LED Light Status Conditions 118 Contact Technical Services at 800 377 4384 with any questions Visit our website at www solahd com SO D Power Supplies 3 SDN C Specifications Single Phase Catalog Number Description SDN 5 24 100C SDN 10 24 100C Nominal Voltage 115 230 Vac AC Range 85 264 Vac DC Range 90 375 Vdc 43 67 Hz Nominal Current 1 65 0 55 A 3 2 1 0A lnrush currentmax Typ lt 15A Typ lt 30 A Efficiency Losses gt 88 typ 14 W gt 90 typ 24 W Power Factor Correction Active power factor correction to better than 0 92 lt 2 overall combination Line load time and temperature related changes lt 35V 10 A 240W Short Circuit Current 1 5 x Nominal Current at near zero volts at short circuit condition Switch selectable single unit or parallel unit operatio
10. ormation 122 Contact Technical Services at 800 377 4384 with any questions Visit our website at www solahd com SOLA HD Power Supplies 3 SDN C Series Mounting Chassis Mounting Dimensional Diagram in mm Instead of snapping a SolaHD SDN unit on the DIN Rail you can also attach it using the screw mounting set SDN PMBRk2 This set consists of two metal brackets which replace the existing two aluminum profiles 70 17 8 43 10 9 23 5 8 LANCE tary 60 15 2 R 03 51 13 0 js 2 16 54 9 1 80 45 7 08 2 0 a Ure 23 5 8741 F 26 6 6 a 52 13 2 52 13 2 21 X 50 LG SLOT QTY 2 15 X 24 LG SLOT WIDTH OF POWER SUPPLY 1 04 DIN Rail Mounting Snap on the DIN Rail 1 Tilt unit slightly backwards Put it onto the DIN Rail Push downwards until stopped Push at the lower front edge to lock O A W N Shake the unit slightly to ensure that the retainer has locked Alternative Panel Mount Using the optional SDN PMBRK2 accessory the unit can be screw mounted to a panel i Click Contact Technical Services at 800 377 4384 with any questions 123 Visit our website at www solahd com
11. t Technical Services at 800 377 4384 with any questions Visit our website at www solahd com SO L D Power Supplies 3 SDN C Specifications Three Phase Catalog Number apse uh SDN 5 24 480C SDN 10 24 480C SDN 20 24 480CC SDN 40 24 480C S ne A Aa T Cege O O y oo SSS BT S E T S S T S S tpg lt 2 overall o Ripples SOO 20 A 480 tant not Nominal Current 5 A 120 W 10 A 240 W l a per 40 A 960 W Dering ty Wty Wty Wty ABW Voltage Fall Time lt 150 ms from 95 to 10 rated voltage full load T me 25 C lt 50 ms from 95 to 10 rated voltage full load Ta n 25 C Parallel 0 tion Single or Parallel operation selectable via front switch For redundant Kees sachidee scab operation use of external diode module is preferred g SLE e ee eC a ee ee en EE Fully enclosed metal housing with fine ventilation grid to keep out small parts 25mm above and below or 25mm above and below or 7Omm above and below or 7Omm above and below 15mm in Free Space 15mm in front 10mm in front 25mm in front and 25mm left amp right front 25mm left amp right 123 0 x 50 0 x 111 0 123 0 x 60 0 x 111 0 123 0 x 85 0 x 119 0 123 0 x 180 0 x 119 0 EN61000 6 3 2001 Class B EN55011 EN55022 Radiated and Conducted including Annex A EN61000 3 2 EN61000 6 1 2001 EN61000 6 2 2001 EN61000 4 2 Level 4 EN61000 4 3 Level 3 EN61000 4 6 Level 3 EN61000 4 4 Level 4 input and level 3 output EN61000 4 5 Isolation
12. t full load Power Good Current Monitor Current Balance signal GND 6 Ripple noise is stated as typical values when measured with a 20 MHZ bandwidth 10 70 maximum rated load Contact Technical Services at 800 377 4384 with any questions 121 Visit our website at www solahd com 3 Power Supplies SOL Ag D SDN C Series Dimensions q W gt Catalog Dimensions inches mm Number OOO A H i W D SDN 5 24 100C 4 85 123 0 1 97 60 0 4 36 111 0 oa al SDN 10 24 100C 4 85 123 0 2 36 60 0 4 36 111 0 ie SDN 20 24 100C 4 85 123 0 3 42 87 0 4 98 127 0 SOLA SDN 5 24 480C 4 85 123 0 1 97 50 0 4 36 111 0 Power Supply eee ee ee SDN 10 24 480C 4 85 123 0 2 36 60 0 4 36 111 0 SDN 20 24 480CC 4 85 123 0 3 35 85 0 4 68 A 19 0 SDN 40 24 100C and SDN 40 24 480C Dimensions Power Supply 5 51 in 139 96 mm Signal Connector D 0 54 in 13 80 mm Catalog Dimensions inches mm Number H W SDN 40 24 100C 4 85 123 0 7 09 180 0 4 66 118 0 SDN 40 24 480C 4 85 123 0 7 09 180 0 4 81 122 0 1 SDN 40 24 100C and SDN 40 24 480C output signaling terminal block features Shut Down Power Good Current Monitor Current Balance GND and active current sharing through ILSHARE connectors See Signals Manual for connection inf
13. unit connector size range 16 10AWG 1 5 6mm7 for solid conductors Screw Torque 4 4 Ib in 50 N cm Output connector size range wire gauge Connections 7 6 AWG 10 6 13 mm2 for solid conductors Screw Torque 15 6 Ib inch 176 N cm for SDN40 all other models 16 10AWG 1 5 6mm for solid conductors Screw Torque 7 lb inch 80 N cm 1 SDN 20 will operate at 75 load SDN 40 will operate at 50 load under loss of 1 scope and 50 Ohm resistor phase SDN 5 and SDN 10 will operate with single phase input power at 100 of load 7 SDN 20 and 40 unit will go to HICCUP mode SDN 5 and 10 will maintain min 4 Unit will shut down if thermal threshold is exceeded under this condition secs to deliver 150 load then drops to almost zero Vu The output voltage will im 2 Unit passed input voltage overstress test at 600 Vac without failure mediately drop to almost zero when load rises above 150 3 Input current ratings are specified with low input line conditions worst case ef 8 All models except the 40amp unit are capable of parallel operation by use of a ficiency values and power factor spikes Input Current at nominal input settings will jumper pin accessible by the end user 40 amp unit will have active current sharing typically be half these values signal 4 Losses are heat dissipation in watts at full load nominal line 9 SDN 40 24 100C only Output signaling terminal block features Shut down 5 24 28 Vdc adjustable guaranteed a