Home

Manual - NEXTLAN

image

Contents

1. Hardware Installation In this paragraph we are going to mention how to install the 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch and the installation points to be attended to it Installation Steps 1 Unpack the Industrial switch packing 2 Check if the DIN Rail is screwed on the Industrial switch or not If the DIN Rail is not screwed on the Industrial switch please refer to DIN Rail Mounting section for DIN Rail installation If user want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5e above cable for Ethernet connection 6 Insert one side of the RJ 45 cable into the Industrial switch Ethernet port and another side to the network device s Ethernet port e g Switch PC or Server The UTP STP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication 7 When all connections are set and L
2. Features m System Interface Performance RJ 45 ports support Auto MDI MDI X Function Embedded 4 port PoE Injection Store and Forward Switching Architecture Back plane Switching Fabric 1 0Gbps 2K MAC Address Table m Power Supply gt DC 48V Redundant Power Case Installation gt IP 30 Protection gt DIN Rail and Wall Mount Design Provides EFT protection 3 000 VDC for power line Supports 6 000 VDC Ethernet ESD protection VV VV WV Package Contents Please refer to the package contents list below to verify them against the checklist 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch User manual Pluggable Terminal Block 2 wall mount plates with screws One DIN Rail attached on the switch Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Hardware Description In this paragraph the Industrial switch s hardware spec port cabling information and wiring installation will be described Physical Dimension 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch dimension W x D x H is 30mm x 95mm x 140mm Front Panel The Front Panel of the 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch is shown as below P1 P2 Fault m E Lantech IPES 0104FT 40 30 FWD m om LOVDINT D fd YMS BLUISNPUl 1093 U 30d Y M X4OOL L XLOOL OL Front Panel of the PoE Injectors Industrial S
3. UTP STP Cat 5 5e cable EIA TIA 568 100 ohm 100m Multi mode 50 125yum 62 5 125um Single mode 9 125um Available distance 2km multi mode 30km single mode Wavelength 1310nm Multi mode Single mode Redundant power DC 48V with removable terminal block 4 6Watts without PoE 58Watts Full load with PoE DIN rail kit for DIN type cabinet install and wall mount ear for wall mounting 40 C to 75 C wide operating temperature model 20 C to 60 C standard model 5 to 95 Non condensing 40 C to 85 C IP 30 30 mm W x 95 mm D x 140mm H FCC Class A CE EN61000 4 2 3 4 5 6 8 1 1 12 CE EN61000 6 2 CE EN61000 6 4 UL cUL CE EN60950 1 IEC60068 2 32 Free fall Stability testing IEC60068 2 27 Shock IEC60068 2 6 Vibration
4. or single mode 30Km When you connect the fiber port to another one please follow the figure below to connect accordingly Wrong connection will cause the port cannot work normally SC Connector Cable Wiring SC to SC Tx A A Rx Tx B _ B Rx the Laser LED Beam ATTENTION This is a Class 1 Laser LED product Don t stare into Cabling m Twisted pair segment can be connected with unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long m Fiber segment using single mode connector type must use 9 125um single mode fiber cable m Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable Wiring the Power Inputs Please follow the steps below to insert the power wire V V V V Insert the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing the wires from loosing Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form an open circuit An application exampl
5. the switch can connect to another switch or workstation without changing straight through or crossover cabling See the below figures for straight through and crossover cable schematic m RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD Switch Router or PC 3 TD gt 3 RD 6 TD 6 RD 1 RD 1 TD 2 RD 2 TD Straight Through Cable Schematic Switch Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic E Fiber Port The fiber port of SC type connector can work in multi mode 2Km
6. ED lights all show in normal the installation is complete Network Application This segment provides the sample to help user have more actual idea of industrial switch application For a sample application of the industrial switch see the figure below A Control center Fiber Cable En LAW Le 4 4 amp VOIP Phone IP Camera Wireless AP IEEE 802 3af Compliant Powered Devices Troubleshooting m Verify that is using the right power cord adapter DC 48V please don t use the power adapter with DC output voltage higher than 48V or it will burn this equipment down Select the proper UTP STP cable to construct your network Please check that is using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Q Category 3 4 or 5 cable for 10Mbps connections 100Q Category 5 cable for 100Mbps connections or 100Q Category 5e above cable for 1000Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet m Diagnosing LED Indicators To assist in identifying problems the Switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions m f the power indicator does not light on when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses or surges at pow
7. EE T E AAGE 1 Package Contents ennenen renerne 2 Hardware Description cccccccseesteeeeeeeeeeeeeeeeeeeneenees 3 Physical DIM NSION cccceeeeeceeeeeaeeeeseeeeeeeeeees 3 Front Panel issaseidsseceocssnacnendes sesdusstsncasdasechsccentinsseseoce 3 TOPVIEW a a a ean ees 4 LE DUINGICAtONS Avi cast tien sen wicerehestew Aiewlaeieeeniies 5 PONS aana atts ee a I is 6 GANG aeaa a 3a eee I ce 8 Wiring the Power Inputs ceeeeeeeeeeeeeeeeeeeeees 9 Wiring the Fault Alarm Contact c eee 10 Mounting Installation ccccssessseeeseeseesseeeeeeeneeees 11 DIN Rail Mounting is sisien 11 Wall Mount Plate Mounting sseeeeeeeseeeeeees 13 Hardware Installation ccccssssssseeeesessessseeeseeeeeees 14 Installation SlICOS sasgui ns tessaeeawsacrendaraiaaieaauaaaeaads 14 Network Application cccccccsecseeseeeeneeeeeeeeeeeeeees 15 Troubleshooting 3 aii hirckcei ae meres 16 Technical Specification cscscccccessnsssssessssesnees 17 Introduction The 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance Besides the industrial switch provides the PoE function for kinds of Powered Devices to receive power as well as data over the RJ 45 cable
8. Lantech IPES 0104FT 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch User Manual V1 01 Nov 2007 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Content IMT FOGUCTION mA E E EE E eereiar eee 1 POAUMCS sas
9. e for the fault alarm contact is shown as below Insert the wires into the fault alarm contact Note The wire gauge for the terminal block should be in the range between 12 24 AWG Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 Use the screws to screw the DIN Rail on the rear side of the industrial switch 2 To remove the DIN Rail reverse the step 1 3 After the DIN Rail is screwed on the rear side of the switch insert the top of DIN Rail into the track 4 Then lightly push the DIN Rail into the track 5 Check if the DIN Rail is tightened on the track or not 6 To remove the industrial switch from the track reverse steps above Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse steps above 13
10. er outlet If you still cannot resolve the problem contact the local dealer for assistance m f the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit Please check your system s Ethernet devices configuration or status Technical Specification The 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch technical specifications is shown as below IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX Fast Ethernet Standard IEEE802 3x Flow Control and Back Pressure IEEE802 3af Power over Ethernet 14 880 pps for 10Base T Ethernet port Transfer Rate 148 800 pps for 100Base TX FX Fast Ethernet port MAC Address 2K MAC address table 10 100TX 4 x RJ 45 with auto MDI MDI X function Supports PoE injector function Connector 100M fiber 1 x SC type connector for Single mode or Multi mode type fiber cable RJ 45 port 1 4 support IEEE 802 3af End point Alternative A mode Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 Data 1 2 3 6 PoE Pin Assignment Per unit Power 1 Green Power 2 Green Fault Red Fiber Link Active Green TX Link Active Green Full duplex Collision Yellow PoE Feeding Power Green Network Cable Optical cable Power Supply Power Consumption Installation Operating Operation Storage 10Base T 2 pair UTP STP Cat 3 4 5 5e cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair
11. witch Top View The top view of the 4 10 100TX 1 100FX w 4 PoE Injector Industrial Switch has one terminal block connector of two DC power inputs PWR2 1A 24V__ PWRI OERS VZN ZEE NVA ViI Vit Fault Top View of the PoE Injectors Industrial Switch LED Indicators The diagnostic LEDs located on the front panel of the industrial switch provide real time information of system and optional status The following table provides the description of the LED status and their meanings for the switch LED Color Description On Power input 1 is active Pi Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 has failed Fault Red Si Power input 1 and 2 are both functional or no power inputs On The port is supplying power to the powered device FWD 1 4 Green 5 Off No powered device attached or power supplying fails On Connected to network 5 LNK ACT ar Green Flashing Networking is active fiber port Off Not connected to network Green On Connected to network Upper Flashing Networking is active LED Off Not connected to network 1 4 RJ 45 Yellow On Full duplex link Lower Flashing Collision occurs LED Off Half duplex link or link down Ports m RJ 45 ports The UTP RJ 45 Fast Ethernet ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that

Download Pdf Manuals

image

Related Search

Related Contents

Port Designs Zurich Trolley  service manual, fork assembly replacement  GK800-T Dedicated User Manual for Tension Control  DSC & D-Cell Manual 2.9mb    Allgemeines Arbeiten mit der Workplace  粕屋町学校給食共同調理場整備運営事業 事業契約書(案)  SEーK。GーKEN ーNC. 超音波噴霧器  Valérie CHAUMARAT Traductrice indépendante  G-Connect 101  

Copyright © All rights reserved.
Failed to retrieve file