Home

Kam LED Partybar V2

image

Contents

1. INSTRUCTION MANUAL LED PARTYBAR V2 otand or floor mount LED par can kit M A N U A L V E R S IO N 1 0 08 09 11 Superb colour wash effects LED RGB lighting Fully positional par cans Complete with a lighting stand footswitch controller and rig bags Compact slimline low profile lights Adjustable lighting stand Built in auto programs Built in sound activated programs Two peddle footswitch for easy operation DMX512 mode Sound to Light mode Master Slave operation 81 LEDs per light 27 x red LEDs 27 x green LEDs 27 x blue LEDs For the latest instruction manual updates and information on the entire Kam range visit www kam co uk Kam products are manufactured by Lamba plc Unit 1 Southfields Road Dunstable Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal Due to continuous product development specifications and appearance are subject to change Copyright Lamba plc 2010 E amp OE Thank you for purchasing this KAM product we are sure that it will serve you for many years to come To optimise the performance of this product please read these operating instructions carefully to familiarise yourself with the basic operations of this unit After you have read the instructions please retain them for fut
2. Please make a note of this number as you will need it for your warranty it is a good idea to keep a copy of the serial number for your own records Function The unit has five working modes Auto mode Built in programs not controlled by foot pedal controller Manual mode RGB colour mix Audio mode automatic built in programs Sound activated DMX512 mode DMX512 control via controller Foot Switch mode Hold black out and control programs via the foot pedal Ob 3 mode this allows control of unit using just 3 dmx channels RGB Control functions via Built in control menu MENU UP DOWN ENTER Use the MENU button to select the mode required Once you have made a selection then press ENTER to confirm This product has a memory function It will go directly into DMX mode after switching on it shows A001 Once a menu has been selected the next time it is powered on the unit will show the mode you previously finished on _ ENTER UP DOWN ENTER Mode Digital display DMX512 A 001 A 512 A 512 A 001 mode DMX address selection DMX address selection AP01 AP12 AP12 AP0 Built in programs built in programs Auto mode F 00 F 08 F 08 F 00 8 speed options note 00 is 8 speed options note 00 is Static static r 00 r 08 r 08 r 00 intensity of red colour 0O off intensity of red colour 00 off 08 brightest 08 brightest a g 00 g 08 g 08 g 00 Specificatio
3. 6 Internal program running 5 Mode 7 Internal program running 6 Mode 8 Internal program running 7 Mode 9 Internal program running 8 Mode 10 Internal program running 9 Mode 11 Internal program running 10 Mode 12 Internal program running 11 Mode 13 Internal program running 12 Mode 14 250 255 4 kinds of Audio mode Options Note to operate Ch1 Ch3 must have a speed value set CH2 Dimmer 0 100 Rgb brightness 0 100 a Strobe speed chase speed No Strobe Strobe or Running speed choose Working mode Options Stand alone Mode Stand alone You can choose between Auto Manual mode Audio mode Use the MENU UP DOWN and ENTER buttons to select the desired mode Stand alone master slave Connecting several units together without a DMX controller Setting the master unit 1 Press the menu button to select the desired mode auto sound manual RGB 2 Press enter to confirm Setting the slave units 1 Press the menu button until A is displayed 2 Use the up down buttons to select A001 3 Press the enter button to confirm 4 All slave units must be set to A001 Please note only one unit must be set as a master The slave units will follow the controls from the master unit The foot pedal can be connected to the master unit to control all attached units Light Remember 4 pan eiee uc te ware to connect AC Power Master Using a DMX controller Each unit uses 15 DMX channels To control all units the same the DMX value must be set t
4. er to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons Caution to prevent the risk of electric shock do not attempt to open the unit No user serviceable parts inside Refer all servicing to qualified service personnel The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance Any modification carried out on the unit may invalidate the unit s warranty If applicable only use the stand tripod or bracket specified or sold with the apparatus Select the installation location of your unit carefully Avoid placing it in direct sunlight or locations subject to vibration and excessive dust Do not use the unit where there are extremes in temperature below 41 F 5 C or exceeding 95 F 35 C Unpacking and safety Please unpack your new product carefully your new product should reach you in perfect condition Please check that no damage has occurred during transit If any damage is found do not operate your unit Please contact the retailer you purchased it from immediately If there is any damage to the mains cable do not use the device Always disconnect the unit from the mains supply when carrying out any servicing or cleaning of the unit The serial number for this equipment should be located on the rear or underside of the unit
5. he same on all units example A001 To control units individually each unit must have its own dmx start address and each address must be at least 15 channels apart No DMX address values must cross Example unit 1 set to A001 unit 2 set to A016 etc each 15 channels apart Using ob 3 mode To select ob 3 mode 1 Press the menu button until ob 3 is displayed 2 Press enter to confirm This is designed to use a basic 3 channel DMX controller and will only give control of the RGB of all par cans Individual control of each can is not available nor are any of the built in programs Trouble Shooting Check list Trouble Shooting 1 Check if the power cord is connect in the input 1 Make sure there is mains present to the mains socket of the party Bar cable check the fuse or replace cable 2 Check if the ambient temperature in a safe 2 After the temperature is suitable the protect range function will cancel automatically No Output The product does not work l 1 Check if the power cord is connect in the input 1 Make sure the mains input voltage is the LED dimmed mains socket of the party Bar correct voltage 1 Check the cable is damaged or Whether the polarity of the pin connections is correct No DMX input 2 Check If it is in DMX mode 3 Check If there are 2pcs master in the whole circuit 1 Correct the DMX polarity or change the cable 2 Set up the function mode as DMX 3 Set 1pcs in slave mode
6. irm Function introduction DMX512 mode To receive DMX512 controller and the slave data Auto mode There are 12 modes under this the auto mode from AP01 to AP12 on every mode you can set the running speed Manual mode Direct R GB control of colour and strobe speed can be manually set under this mode The display will show r 00 r 08 as you increase the value the LED brightness increase and change The display will show g 00 g 08 as you increase the value the LED brightness increase and change The display will show b 00 b 08 as you increase the value the LED brightness increase and change F 00 F 08 is the Strobe Speed option and as you increase the value the Strobe speed will increase and change Audio mode Under this mode please adjust the Audio Sensitivity control knob on the rear panel to a suitable position meanwhile there are 4 modes from SP00 to SP03 as you increase the value the sound mode will increase and change Use the MENU button to select the mode required Once you have made a selection then press ENTER to confirm Foot Switch mode There are 20 modes that can be selected APO1 AP12 is the internal auto program ALL means these 12 internal programs running constantly DMX Channels Channels Function DMX542 Description O Z o Z Mode 1 0 97 RGB Color adjustment Mode 2 Internal program running 1 Mode 3 Internal program running 2 Mode 4 Internal program running 3 Mode 5 Internal program running 4 Mode
7. n intensity of green colour intensity of green colour modification QO off 00 off Save and Manual 08 brightest 08 brightest run b 00 b 08 b 08 b 00 intensity of blue colour intensity of blue colour 00 off 00 off 08 brightest 08 brightest F 00 F 08 F 08 F 00 Increase Strobe speed 00 Decrease Strobe speed 00 static 08 fast strobe static 08 fast strobe SP00 SP03 SP03 SP00 Audio mode Increase 4 possible audio Decrease 4 possible audio sensitivity sensitivity Obey3 eon No function No function dmx only rgb Foot switch The foot switch has 2 pedals The left pedal is blackout on Pressing the left pedal once will blackout the unit and all par cans will go off Pressing the left pedal once again the unit will light and return to the position the unit was in before black out was pressed In blackout mode the display will show HAA Using the right hand foot pedal programs poc4 By pressing the program pedal the unit will step through the built in options Auto programs 1 12 and Auto programs ALL The digital display will read APon gt AP01 gt AP02 gt AP03 gt AP04 gt AP05 gt AP06 gt AP07 gt AP08 gt AP09 gt AP10 gt AP11 gt AP12 gt ALL as you step through the selection You also can step on the PROGRAMS footplate again to select into R gt G gt B gt RG gt GB gt RB gt RGB gt modes Use the MENU button to select the mode required Once you have made a selection then press ENTER to conf
8. ure reference This unit has been tested at the factory before being shipped to you To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture To prevent a fire hazard do not expose the unit to any naked flame sources Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time When installing the unit please ensure you leave enough space around the unit for ventilation Slots and openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating To prevent fire hazard the openings should never be blocked or covered Always handle the power cable by the plug Never pull out the plug by pulling on the cable Never touch the power cable when your hands are wet as this could cause an electric shock Do not tie a knot in the cable The power cable should be placed such that it is not likely to be stepped on A damaged power cable can cause a fire or give you an electrical shock Check the power cord periodicaly if you ever find that it is damaged replace it before using the unit again Contact your retailer for a replacement The voltage of the available power supply differs according to country or region Be sure that the power supply voltage of the area where this unit is to be used meets the required written on the unit The lightning flash symbol inside a triangle is intended to alert the us

Download Pdf Manuals

image

Related Search

Related Contents

ダウンロードはこちらから(容量 10242KB)  Pocket-Pro Joinery System.indd  Manual de Instruções de Uso  気象警報発令時の対応について  "Pas les gaz€!" - Grands Reporters  Series 35 Rover Manual V2  TBB45402EU| Targus 13 - 14.1 inch / 33  Instrucciones de servicio Edición 05/2005 - Services  Samsung HT-DB750 Instrukcja obsługi  JSNDI 2008 年秋期 UT レベル 1,レベル 2 実技試験対策講習会のご案内  

Copyright © All rights reserved.
Failed to retrieve file