1. The user code group1 and user code code group2 can contain 40 group passwords If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and the digitals you input before will be cleared at the same time The user code can not be set the same as the master code and temporary code Unlocking of user code When the registered user code has been input using the keypad 1 12 digits the LED indicator group 1 red group 2 blue lights up the buzzer sounds and the electric door strike is unlocked Example group 1 Example group 2 2011 2012 Red LED lights up Blue LED lights up during relay1 operation during relay2 operation red blue d blue ON OFF ON re OFF oe O The time interval during which the button must be pressed is approximately 10 seconds If the time interval exceeds approximately 10 seconds the input value will be cleared If you make a mistake when inputting the user code press the cancel button and input the user code again When the Lockout function has been activated the release function is forbidden and the input operation is disabled for 60 seconds if 10 times incorrect access codes are continuously attempted Lockout function When Lockout is activated the relay 2 doesn t respond the second lock but responds the LOCKOUT function After continuously inputing incorrect access code 10 times LOCKOUT output and the relay 2 will b
2. 2 Wire Prestige video system 596KP User Manual Programming the 596KP keypad Basic set up configuration The manual for the 596KP is quite in depth so please refer to the basic set up as written below but also please read the manual carefully Both door panel and video monitor have DIP switches to the rear of them which are used for different configurations mainly they are used if you have multi door panel installations If you have the basic system of 1 x door panel and 1 x video monitor then you do not need to worry about the DIP switches at all they should all be set to the OFF position To program the 596KP keypad for basic set up configuration in less than two minutes you will need to enter the program mode by entering the master default code The default master code is 1234 so you would press 1234 1 x hash The Red LED will light up to confirm you are now in the programming mode If you do not press any button for up to 60 seconds the keypad will exit from the programming mode To manually exit from the programming mode press the key 1 x star To program a user code only example code 9009 Enter the programming mode by pressing the master code of 1234 1 x hash Press 21 this is user code position 1 Press 9009 this is your new user code if successful the keypad will bleep twice Press to exit 1 x star Press the user code 9009 to test and the Red LED will light to confirm relay one is activated To progra
3. red blue ON ON ON ON ON ON o o Beept Beep Beep Beep o o Beept Beep Inputting of new master code ex 4321 1 12 digits 4321 red blue ON OFF Inputting of code ex 10 range 00 or 10 99 10 blue OFF Inputting of code ex 09 range 01 99 09 red blue red ON o o o o o red OFF blue OFF Beep Beep The unlock time can be set on both monitor and door station and the valid value is the number you set last time The master code is allowed 1 12 digits the same code cannot be set for both the user code and the master code it is recommended that you modify the default master code If the key illumination time is set to 00 the key illumination will light up all the time when power on If the key illumination time is set to 10 99 the key illumination will light up for 10 99 seconds At this mode the key illumination lights off in standby mode touching any digital key can illuminate but this is the invalid digital red blue Input the master code Default 1 2 3 4 o Beep Beep SAA 5 Setting the unlock mode 6 Setting operation tone 7 Reset code setting 8 amp function setting Default C opened Default ON Default Normal Input the setting code Input the setting code Input the setting code Input the setting code 04 05 06 O7 red blue red blue red blue red blue ON ON ON ON N O ON
4. red blue ON OFF o 0 Beep Beep 14 Setting the code for user group1 15 Setting the code for user group2 20 59 Input the setting code ex 21 21 60 99 Input the setting code ex 60 60 red blue red blue ON ON ON ON o Beep Beep o o Beept Beep Inputting of code ex 2011 1 12 digits 2011 red blue ON OFF Inputting of code ex 2012 1 12 digits 2012 red blue ON OFF red blue OFF When the cancel key is pressed the LED lights off the buzzer beeps and the system exits the setting mode OFF When there isn t any operation in 10s the LED lights off the buzzer beeps and the system exits the setting mode o fe When input the correct temporary password to release the door the system will clear the temporary password after 60 seconds automatically But you should know that the password is valid within 60 seconds after inputing the correct temporary password The temporary1 is used to release the first lock and the temporary 2 is used to release the second lock If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and the digitals you input before will be cleared at the same time The temporary code can not be set the same as the master code and user code Beep Beept The user code group1 is used to release the first lock and the user code group2 is used to release the second lock
5. 1 12 digits forTemporary2 Valid keys 0 9 1 12 digits Setting the ae Jct Number of codes 40 group Valid keys 0 9 1 12 digits Number of codes 40 Valid keys 0 9 Setting the code for user group2 Input the master code Default 1 2 3 41t 1 1 Reset all settings Input the setting code 00 red blue ON ON o o Beept Beep Inputting of code 1234 red blue When the cancel key is pressed the LED lights off the buzzer beeps and the system exits the setting mode When there isn t any operation in 10s the LED lights off the buzzer beeps and the system exits the setting mode o AIl settings will restore to their default value When power on or activate the reset all setting item the keypad checking will carry out during this time the key illumination will blink and the touching operation is forbidden after finish checking the key illumination will stop blinking and sent out a long sound of beep red blue Each operation is indicated by the lighting up of the LED indicators on the right section of the unit and by the sounding of the buzzer red blue ON OFF oe o o Beept Beep 2 Setting the master code Default 1234 3 Setting the key illumination time Default 10s 4 Setting the unlock time Default 1s Input the setting code 01 Input the setting code 02 Input the setting code 031 red blue red blue
6. ON o oe Beept Beep o o Beept Beep o o Beept Beep o o Beept Beep Inputting of code ex 1 Inputting of code ex 1 Inputting of code Inputting of code ex 1 range 0 open 1 close range 0 on 1 off range 0 normal 1 reverse 1 1 1234 1 red blue red blue red blue red blue ON OFF ON OFF ON OFF ON OFF red blue When the cancel key is pressed the LED lights off the buzzer beeps and the system exits the setting mode OFF OFF When there isn t any operation in 10s the LED lights off the buzzer beeps and the system exits the setting mode o oO Beep Beep The unlock mode can be set on When the operation tone is Cancel all the passwords except When the item is set to 0 press both monitor and door station set to 0 pressing the digital the master code the x button to cancel the input and the valid value is the number keypad will sent out a sound Restore the master code to and press the button to confirm you set last time of beep default value 1 2 3 4 the input When the operation tone is When the item is set to 1 press set to 1 pressing the digital the button to cancel the input keypad will blink one time and press the button to confirm the inout Input the master code Default 1 2 3 4 l 9 Call tone setting Default enable Input the setting code 08 red blue ON ON o eo Beept Beep Inputting of code ex 1 range 0 e
7. e closed for 60 seconds the LED relay 2 will be illuminated for 60 seconds During this time the buzzer will continuously sound about 8 times You can activate the electric door strike by pressing the request to exit button connected to the unit Pressing request to exit button 1 releases relay 1 and pressing request to exit button 2 releases relay 2 The unlock function will work when the request to exit button is pushed even while the Lockout function is operating 1 During calling pressing cancel button can cancel the calling 2 If input the incorrect access code the buzzer will sound of beep beep beep The maximum distance of the wiring is limited in the DT system Using different cables may also affect the maximum distance which the system can reach The farest monitor When Monitor quantity lt 20 CAT5 6 Paired wires 40 80 30 Paralled cable2x0 75mm 30 50 40 Twisted cable 2x0 75mm 60 60 30 Twisted cable 2 x Imm 80 80 40 Non shielded cable only 18
8. m the lock release timer Enter the programming mode by pressing the master code of 1234 1 x hash Press 03 then 09 for 9 seconds Press to exit 1 x star Enter 9009 and the keypad Red LED will light up for 9 seconds To change the master default code of 1234 to 5678 or your chosen number Enter the programming mode by pressing 1234 1 x hash Press 01 Press 5678 this is your new master code if successful the keypad will bleep Press to exit 1 x star Important do NOT forget your new mater code as you cannot reset the keypad without the master code Camera Lens Speaker Touch Sensitive Digital Keypad 23 mm Nameplate Call Button Microphone Rainy Cover e Lock Control Jumper Doorstation Code DIP MIC adjustment e SPK adjustment Main Connect Port amp PL Sit S2 ae AS Lock Control Jumper To select the lock type see section 5 e Doorstation Code DIP Total 4 door stations can be supported see section 6 MIC Adjust the volume of Microphone e SPK Adjust the volume of Speaker Main Connect Port To connect the bus line and the electronic locks e BUS Connect to the bus line no polarity e PL External lock power input connect to the power positive power 1 2 Lock power output to connect 2 locks Lock power output connect to the power inpu
9. nable 1 disable 1 red blue ON OFF o oO Beept red blue ON OFF o O 10 Interference resistant grade setting Default 2 Input the setting code 09 red blue ON ON Beep Beep Inputting of code ex 3 range 0 5 31 red blue ON OFF Oo Whenthe cancel key is pressed the LED lights off the buzzer beeps and the system exits the setting mode When there isn t any operation in 10s the LED lights off the buzzer beeps and the system exits the setting mode If the item is set to 0 the unit will respond a call tone when pressing the CALL button If the item is set to 1 the unit will have no responds when pressing the CALL button The larger you set the interference resistant grade the stronger it will be but the sensitivity of the keypad will be more lower The interference resistant grade setting also will activate the keypad checking Beept Beep red blue OFF OFF O O Beep Beep Input the master code Default 1 2 3 4 1 12 Setting the code forTemporary1 Input the setting code 18 red blue ON ON oe Beept Beep Inputting of code ex 1006 1 12 digits 13 Setting the code forTemporary2 Input the setting code 19 red blue ON ON o Beep Beep Inputting of code ex 2011 1 12 digits 1006 2011 blue OFF red blue red ON OFF N o O o oO
10. t of locks only when using the camera to power the locks if using the external power supply for the locks the S will not be connected Drill holes in the wall to match the size of Connect the cable correctly and adjust screws and attach the rainy cover to the wall right angle for camera i Attach the panel to the rainy cover Use the screwdriver and the screw to fix the panel Placing Name Label Move the plastic cover away to open the transparent name label cover insert a name paper then put the plastic cover back to the panel use a screwdriver to loosen the screw and adjust the 208000 angle for the camera then fix the screw der Setting items Setting range Default value Setting code Reset all settings 1 2 3 4 1 12 digits Setting the master code Valid keys 0 9 1 2 3 4 Setting the key 10 to 99 seconds ee illumination time continually lit Setting the unlock time 01 to 99 seconds 1 seconds Setting the unlock mode 0 opened 1 closed opened Operation tone settings 0 on 1 off Reset code settings 1 2 3 4 X amp function settings 0 Normal 1 Reverse Normal Call tone settings 0 Enable 1 Disable Enable Interference resistant Valid keys 0 5 2 grade settings Reserve not used Reserve Setting the code 1 12 digits forTemporary1 Valid keys 0 9 Setting the code
Download Pdf Manuals
Related Search
Related Contents
User`s Manual - File Management Swiss SA Sharp Y0-P5 User's Manual 取扱説明書(PDF: 0.1 MB) トラクター EcoTra EG-PRO Series プレミアム EG76・EG83 Samsung Galaxy Tab 4 7.0 (LTE) Instrukcja obsługi Ecole Nationale Supérieure d`Informatique et d`Analyse des systèmes SoundGate 3 Bedienungsanleitung Copyright © All rights reserved.