Size: 651 kB 5th Jul 2013 BIOMERGE-PX User Manual

image

Contents

1. 5 SP1 SQL 2008 R2 Express BIOMERGE PX 3 Run through the installer which may prompt for several reboots depending on the pre requisites it installs 4 On completion restart the PC NB If the Windows 7 operating system is being used we recommend that User account and Areo themes are disabled and a basic theme used Also the software should only be used with an account having administrator privileges First Time Using BIO MERGE PX Once the PC is rebooted BIO MERGE PX starts automatically BIO MERGE PX can be found in Start gt All Programs gt Start up folder On first run the software requires to be licenced The licence window will popup advising a licence is required Contact your vendor and supply the site id and company name Vendor will generate licence key Enter licence key and press Save Licence If licence key is valid the window disappears RO ND NB Please ensure all respective Paxton ACU s are connected to the Paxton Server otherwise there may be naming issues as BIO MERGE references the readers by their ACU ID ices ST Site ID 1453 fasie 80704 Copy 60096 Paste 00770 0 16 Demo license expires 04 April 2013 BIOMERGE PX PACS Settings On installation BIO MERGE PX is configured to connect to Paxton software on the target machine using the System engineer account and the default password of net2 The credentials can be changed providing the Paxton
2. LED Green LED Data DO Clock D1 Media detect Ov io ee GNDYBK NY INI RE 4 R DY OR 3 W iegand Cable SP E SGJCGJJ _ OUT YE 1 OUTO BE I Wiegand Connections Using the supplied Wiegand connector Connect Black Wiegand Out 0 To D O on ACU Connect Yellow Wiegand Out 1 To D 1 on ACU Connect Brown Ground To OV GND on the ACU BIOMERGE PX 11 TERMINAL SET UP QUICK START GUIDE There are two basic requirements to follow to get your system up and running 1 Set up the terminal IP Server IP and Terminal ID 2 Set up Wiegand output format in the terminal The Virdi terminals communicate via TCP IP to the allocated server where the Biomerge software is installed Please follow the steps below for configuration TCP IP SET UP 1 TERMINAL IP SET UP Press and hold ENT to enter menu Select option 2 Network Select option 1 IP Address Use F4 to delete characters and type in new IP address using keypad Hold Down Enter for next step or to Exit 2 SERVER IP SET UP Press and hold ENT to enter menu Select option 2 Network Select option 2 Server IP Use F4 to delete characters and type in new IP address using keypad Hold Down Enter for next step or to Exit 3 TERMINAL ID SET UP Press and hold ENT to enter menu Select option 2 Network Select option 3 Terminal ID Use F4 to delete characters and type in ID using keypad Press enter and select option 4 Terminal Only H
3. PX The database window is displayed Select the terminal from the drop down list Once selected the data for the terminal will show in the data grid Click the Restore Data to terminal button to restore the data Confirm the message warning N O18 W Uploading Firmware to a Terminal To upgrade a terminal s firmware Right click G icon in the system tray Click on Firmware Upload Select terminal from drop down list The current firmware version is displayed To upgrade the firmware press the Upload Firmware button A file dialogue window appears allowing you to locate the firmware file Select firmware file and click Open Wait until message box confirms success Firmware Upload x O NOOTRO ND Firmware Version ACz1 00 20 51 07 000 05 HLA2K 3 01 1 100 Upload Firmware A BIOMERGE PX Uploading Files to Terminal To upload files Right click F icon in the system tray 1 2 Click on File Upload 3 Select terminal from drop down list 4 Select file type from drop down list 5 Press Upload Files button 6 Select file and click Open 7 Wait until message box confirms success lie Upload Ioj x Terminal File Type r ext C Y v Upload Files Backup Schedule Backup and Restore Backup It is highly recommended to configure at least one scheduled backup and ensure the backup files are regularly stored on another drive to maint
4. ESS F Genie c Paxton Integration Software User Guide BIO MERGE PX Installation Requirements Minimum PC Specification Supported Operating Systems Windows 7 Windows Server 2008 Windows Server 2008 R2 Windows XP 5P3 Processor Pentium IV compatible processor with a minimum speed of 1 GHz RAM Minimum 2GB Graphics 512 MB PCI2 x16 Network Requirements The following network ports should be allowed TCP IP 9870 Virdi reader server Prerequisites Paxton Net2 version 4 27 or later USB desktop reader drivers on installation disk BIO MERGE PX can only be installed on Paxton Server although in certain circumstances this software will run successfully on a Paxton Client using PACS settings The Card Format should be set to Hexa 2 on all AC2500 terminals and to Hexa on AC5000 terminals Software Installation BIO MERGE PX should be installed on the Paxton server PC Before installing please check the minimum specifications and the prerequisites 1 Load the BIO MERGE PX CD ROM and install the desktop reader drivers by clicking the 1 Install Desktop Reader Drivers button on the auto run menu 2 Click 2 Install BIO MERGE PX for Paxton button on the auto run menu Depending on the software already installed the installer will firstly install all the pre requisites All pre requisites are on the installation CD ROM The pre requisites for BIO MERGE PX are Windows Installer 4 5 Net Framework 3
5. ain the data in the event of a crash m Bio Merge PX Recovery Backup Backup Recover Modity Schedules 1 Right click Gy icon in the oooO system tray Backup Location 2 Click on Backup Restore and heed Schedule 3 Enter a name for the backup 4 Select a location by pressing the button or enter a file path Select Now Press Apply The application closes after backup succeeded Now Schedde N O OT BIOMERGE PX Scheduled Backup To upload files 1 Right click F icon in the e system tray 2 Click on Backup Restore ee and Schedule Backup Location 3 Select a location by E pressing the button or enter a file path 4 Select Schedule 5 Enter first date and time 6 Select Frequency Daily C Weekly Weekly or Monthly Monthly 7 Press OK 8 Application closes when schedule is applied s successfully Recover a Backup To upload files Backup Recover modiy Schedules 1 Right click F icon in the na Nin system tray 2 Click on Backup Restore and Schedule 3 Select the Recover tab 4 Enter file path of backup file or use browse button to select file 5 Press Apply 6 Application closes on successful restore BIOMERGE PX 10 Recover a Backup To upload files i Bio Merge PX Recovery 1 Backup Recover Mod y Schedules Right click y icon in the cc a system tray Click on Backu
6. old Down Enter or to Exit Press F4 twice until you see option to SAVE Press 1 for YES To Save Followed by Enter WIEGAND SET UP Please ensure Wiegand is enabled in the Virdi terminal by following these steps 1 Press and hold ENT to enter reader menu Select option 5 Terminal Select option 4 Wiegand Press ENT to select Wiegand out format Press 3 to select 26 Bit Select site code if applicable or leave as 0 Press and Hold ENT to exit Press F4 twice until you see option to SAVE Press 1 for YES To Save Followed by Enter O e Gol eM GENIE CCTV LTD CCTV House City Park Watchmead Welwyn Garden City Hertfordshire AL7 ILT Tel 44 0 1707 330541 Fax 44 0 1707 330543 www geniecctv com Edition GN July 2013
7. p Restore i and Schedule Select the Recover tab Enter file path of backup file or use browse button to select file Press Apply Application closes on successful restore Modify Schedule To upload files 1 2 Select the Modify Highlight schedule you wish Right click Gy icon in the system tray Click on Backup Restore and Schedule Schedules tab to change Press the Edit Schedule button First tab shows with existing schedule details Amend and press Apply when OK Application closes on successful change BIOMERGE PX Integration Notes amp Connections Overview The Virdi AC5000 fingerprint reader connects to the Paxton NET2 ACU via Wiegand connections and Ground A successful transaction on the Virdi terminal is then interpreted as a Wiegand ID and this is communicated to the NET2 ACU via the conventional Wiegand data connections Power Requirements The AC 5000 reader may be powered from the ACU provided the power supply can provide at least 2 Amps for the Virdi terminal to function correctly under load Alternatively please use the power supply which is supplied with the Virdi terminal In this instance ensure the ground cable brown from the supplied Wiegand cable 5P is connected to O Volt Ground in the NET2 ACU as per illustration below AC 5000 PAXTON NET2 CONNECTIONS Net Reader Connections i2v Red LED Amber
8. synced to the terminal readers BIOMERGE PX Advanced Enrol The Advanced Enrol dialogue box appears Select desired options and click OK The finger print enrolment screen appears click Next Select finger to enrol Read fingerprint on desktop reader Click Finish 0 Fingerprints are automatically synced to the terminal readers OONOD OOF ioj xj Authentication type allows you to select Authentication Type alternative methods for authenticating a user Options are Fingerprint only Fingerprint and Card Fingerprint or Card Card Only Fingerprint and Card When selecting an option that includes a card the card information becomes available The Read Card button allows you to read the card using the desktop reader Note Terminal card format should be set to Hexa AC5000 or Hexa 2 AC2500 Admin User check box turns user into terminal admin This locks normal users from making changes to terminals locally Delete User Users are deleted automatically when they are removed from Paxton or their access level is set to No Access Note BIO MERGE PX should be running at all times to ensure full system synchronisation Restoring Data to Terminal All data that is send to the terminals is stored in a database When required there is an option to restore a terminal using BIO MERGE PX To restore a terminal 1 Right click F icon in the system tray 2 Select Restore Terminal BIOMERGE
9. user has system engineer rights To change the credentials 1 Right click Gy icon in the system tray 2 Select PACS Settings 3 The PACS Settings window appears 4 Enter new details and click OK KET IGI Pacs Server 192 168 2 20 Pacs User Name System engineer PACS Password New Terminal Registration Whenever a new terminal registers with BIO MERGE PX a Terminal Registration window appears Select or type a name for the terminal and select Terminal Type Select send all users to terminal to send existing fingerprints to terminal iti Terminal Name Terminal 3 Send allusers to terminal 00 Yes No BIOMERGE PX Adding a New User 1 2 3 Bio Merge Px 2 of 1000 Users Dix Terminals 1 Biometric Reader 1 2 Terminal 2 Add the user using Paxton Software and select token type as Fingerprint verification card Ensure the user has access rights No access will be ignored BIO MERGE PX dialogue box pops up 3 The Admin User check box enables the user to enter in to terminal ad ministration Check the box To enrol user click on Quick Enrol or Advanced Enrol Fingerprint Number 9 User Name New User UserlD E eiz I Admin User Quick Enrol 4 5 6 r 8 The finger print enrolment screen appears click Next Select finger to enrol Read fingerprint on desktop reader Click Finish Fingerprints are automatically

Download Pdf Manuals

image

Related Search

Related Contents

KORDOFAN BIO  Conectando o Iomega StorCenter ix4-200d  Samsung SEW-5HR122AX User Manual  Symantec Firewall/VPN 200R  HT-FS1  M1.75TC1B41の仕様図はこちら(PDF)  SMART Signage TV Manuale dell`utente  Delta Electronics EMV-APP01 User's Manual  Simulator Configuration Guide for Synopsys Models  Page 1 Page 2 ー全てが次世代記員 魅力のコンパク トボディであり  