Home
User guide
Contents
1. ResMed ClimateLineAir ClimateLineAir Oxy ALLE WY WIR 17 SUAS Min User guide English ENGLISH About your ClimateLineAir The ClimateLineAir is heated air tubing that delivers the desired temperature at your mask ClimateLineAir Oxy is a variant of the ClimateLineAir that has a built in oxygen connector to attach a supplemental oxygen supply When used with the HumidAir humidifier ClimateLineAir heated air tubing allows you to use Climate Control Climate Control is designed to make therapy more comfortable by enabling constant temperature and maintaining humidity The ClimateLineAir heated air tubing is designed for use with AirSense 10 AirCurve 10 devices Please read this entire user guide together with your device user guide before using your ClimateLineAir heated air tubing Note Not all types of air tubing are available in all regions Setup English 1 1 Make sure the device is connected and turned on 2 Hold the orange cuff of the air tubing and line up the air tubing connector with the connector port 3 Push the cuff until the connector clicks into place ClimateLineAir connected will briefly display on the device screen 4 Connect the assembled mask to the free end of the air tubing Setup with supplemental oxygen To set up the ClimateLineAir Oxy with supplemental oxygen perform the steps outlined in the setup section and the following additional steps 1 Remo
2. eed to change any settings but if the air in the mask feels too warm or cold you can adjust the tube temperature to find what is most comfortable for you You can set the Tube Temperature to anywhere between 60 86 F 16 30 C or turn it off completely My Options My Options lt Home Tube Temp Ramp Time Climate Ctrl Tube Temp Mask Run Mask Fit Airplane Mode English 3 To adjust the Tube Temperature 1 In My Options turn the dial to highlight Tube Temp and then press the dial 2 Turn the dial to adjust the temperature and press the dial to save the change Climate Control Manual Designed to offer you more flexibility and control over your settings Climate Control Manual lets you adjust the temperature and humidity to the setting which is most comfortable for you In Climate Control Manual the tube temperature and the humidity level can be set independently however rainout protection is not guaranteed If rainout does occur first try increasing the tube temperature If the air temperature becomes too warm and rainout continues try decreasing the humidity My Options My Options Home Climate Ctrl Ramp Time lt Cancel Climate Ctrl Auto Tube Temp Manual Mask Run Mask Fit gt Airplane Mode Off To change to Climate Control Manual 1 In My Options turn the dial to highlight Climate Ctrl and then press the dial 2 Turn the dial to select Manual and press the dial t
3. lish 5 Disconnecting 1 Hold the cuff of the air tubing apply gentle pressure to the release buttons and pull it away from the device 2 Hold both the cuff of the air tubing and the swivel of the mask then gently pull apart Note Only hold and pull the cuff of the air tubing Do not hold or pull the tubing itself as it may cause damage Cleaning You should clean the air tubing weekly as described 1 Wash the air tubing in warm water using mild detergent Do not wash in a dishwasher or washing machine 2 Rinse the air tubing thoroughly and allow to dry out of direct sunlight and or heat Checking You should regularly check the air tubing for any damage If there are any holes tears or cracks you should replace it Reconnecting the air tubing When the air tubing is dry you can reconnect it to the device 1 Connect the air tubing firmly to the air outlet located on the rear of the device 2 Connect the free end of the air tubing firmly onto the assembled mask Troubleshooting If you have any problems refer to the troubleshooting section of your device user guide or www resmed com Technical specifications Environmental conditions Operating temperature Operating humidity Operating altitude Storage and transport temperature Storage and transport humidity Electromagnetic compatibility Refer to the device User Guide Temperature Temperature range Cut out Operating pressure range Ma
4. o save the change Humidity Level The humidifier moistens the air and is designed to make therapy more comfortable If you are getting a dry nose or mouth turn up the humidity If you are getting any moisture in your mask turn down the humidity You can set the Humidity Level to Off or between 1 and 8 where 1 is the lowest humidity setting and 8 is the highest humidity setting My Options u My Options Home Humidity Level Ramp Time Climate Ctrl Tube Temp Humidity Level Mask Run Mask Fit To adjust the Humidity Level 1 In My Options turn the dial to highlight Humidity Level and then press the dial 2 Turn the dial to adjust the humidity level and press the dial to save the change If you have been using Climate Control Manual and want to return to Climate Control Auto follow the instructions below My Options u My Options lt Home Climate Ctrl Ramp Time lt Cancel Climate Ctrl Manual Auto Tube Temp Manual Humidity Level 4 Mask Run Mask Fit To change to Climate Control Auto 1 In My Options turn the dial to highlight Climate Ctrl and then press the dial 2 Turn the dial to select Auto and then press the dial to save the change Caring for your ClimateLineAir It is important that you regularly clean your air tubing to make sure you receive optimal therapy The following sections will help you with disconnecting cleaning checking and reconnecting your air tubing Eng
5. ollection reuse and recycling systems available in your region The use of these collection reuse and recycling systems is designed to reduce pressure on natural resources and prevent hazardous substances from damaging the environment If you need information on these disposal systems please contact your local waste administration The crossed bin symbol invites you to use these disposal systems If you require information on collection and disposal of your ResMed device please contact your ResMed office local distributor or go to www resmed com environment Limited warranty Refer to your device user guide ResMed ResMed Ltd DISTRIBUTED BY 1 Elizabeth Macarthur Drive ResMed Corp 9001 Spectrum Center Boulevard San Diego ME Bella Vista NSW 2153 Australia CA 92123 USA EC REP ResMed UK Ltd 96 Jubilee Ave Milton Park Abingdon Oxfordshire 0X14 4RW UK See www resmed com for other ResMed locations worldwide For patent and other intellectual property information see www resmed com ip AirSense AirCurve ClimateLine and HumidAir are trademarks of ResMed Ltd ClimateLine is registered in U S Patent and Trademark Office C 2014 ResMed Ltd 378174 3 2014 12 0123 ResMed com NEIN III III NN 378174
6. ve the cap from the oxygen connector 2 Connect the oxygen supply tubing to the oxygen connector Make sure it is firmly attached Notes e Before adding oxygen familiarize yourself with the specific warnings relating to the use of supplemental oxygen These can be found at the end of your device User Guide e If you use the ClimateLineAir Oxy without supplemental oxygen make sure the cap of the oxygen connector is firmly attached Climate Control Climate Control is an intelligent system that controls the humidifier and the ClimateLineAir heated air tubing to deliver constant comfortable temperature and humidity levels during therapy Designed to prevent dryness of the nose and mouth it maintains the set temperature and relative humidity while you sleep Climate Control can be set to either Auto or Manual and is only available when both the ClimateLineAir and the HumidAir humidifier are attached Climate Control Auto Climate Control Auto is the recommended and default setting Climate Control Auto is designed to make therapy as easy as possible so there is no need to change the temperature or humidity settings The Tube Temperature is set to Auto 80 F 27 C and Climate Control adjusts the humidifier output to maintain a constant comfortable humidity level of 85 relative humidity while protecting against rainout water droplets in the air tubing and mask Tube Temperature In Climate Control Auto there is no n
7. ximum recommended pressure Physical Air tubing Material ClimateLineAir Flexible plastic and electrical components ClimateLineAir Oxy Design life Air tubing Standard SlimLine ClimateLineAir ClimateLineAir Oxy Flexible plastic and Symbols electrical components 41 F to 95 F 5 C to 35 C Note The air flow for breathing produced by this therapy device can be higher than the temperature of the room Under extreme ambient temperature conditions 104 F 40 C the device remains safe 10 to 95 relative humidity non condensing Sea level to 8 500 2 591 m air pressure range 1013 hPa to 738 hPa 4 F to 140 F 20 C to 60 C 5 to 95 relative humidity non condensing 60 to 86 F 16 to 30 C 106 F 41 C 25 cm H20 25 hPa Length Inner diameter 6 6 2 m 0 6 15 mm 6 4 1 9 m 0 75 19 mm 6 months The following symbols may appear on the product or packaging onal Manufacturer EC REP European Authorized Representative Catalog number Batch code Rx Only Prescription only In the US Federal law restricts these devices to sale by or on the order of a physician S Humidity limitation i Temperature limitation China pollution control logo 1 China pollution control logo 2 English 7 ye Environmental information This device should be disposed of separately not as unsorted municipal waste To dispose of your device you should use appropriate c