Home

Manual - Test Equipment Depot

image

Contents

1. 5 1 Ib Note 1 Some application modes are restricted in Approved models Note 2 1 and 3 models add 0 5kg 11b Non Approved Models Model Capacity Readability d Repeatability Linearity Span Cal Wt Lin Cal Wts NV212 210g 0 01g 1d 2d 200g 100g 200g NV511 510g 0 19 1d 2d 300g 300g 500g NV1101 1100g 0 19 1d 2d 500g 500g 1000g NV2101 2100g 0 19 1d 2d kg 1kg 2kg NV4101 41009 0 29 1d 2d 2kg 2kg 4kg NV5101 5100g 0 59 1d 2d 3kg 3kg 5kg NVL511 510g 0 19 id 2d 300g 300g 500g NVL1101 1100g 0 19 1d 2d 500g 500g 1000g NVL2101 2100g 0 19 1d 2d 1kg 1kg 2kg NVL5101 5100g 0 59 1d 2d 3kg 3kg 5kg NVL10000 100009 1g 1d 2d 5kg 5kg 10kg NVL20000 200009 1g 1d 2d 10kg 10kg 20kg NVT1601 1600g 0 19 id 2d kg 1kg 1 5kg NVT3201 32009 0 29 1d 2d 2kg 2kg 3kg NVT6401 6400g 0 59 1d 2d 5kg 3kg 6kg NVT10001 100009 0 59 1d 2d 5kg 5kg 10kg NVT16000 160009 1g id 2d 10kg 10kg 15kg EN 10 Note 1 1 Factory installed rechargeable battery option 2 LED display 3 LED display with factory installed rechargeable battery option Navigator Approved Models Modelt2 Max e Approval Class Span Cal Wt Lin Cal Wts NV311 310g 0 19 Il 200g 200g 300g NV3100 3100g 1g Il 2kg 2kg 3kg NVT1601 1600g 0 5g IIl 1kg 1kg 1 5kg NVT3200 3200g 1g Il 2kg 2kg 3kg NVT6400 6400g 2g Il 5kg 3kg 6kg NVT1
2. Europe are available online at www ohaus com Choose your country then search for WEEE Thank you for your contribution to environmental protection EN 12 Navigator FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada Note This Class B digital apparatus complies with Canadian ICES 003 ISO 9001 Registration In 1994 OHAUS Corporation USA was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International BVQI confirming that the OHAUS quality management system is compliant with the ISO 9001 standard s requirements On May 15 2003 OHAUS Corporation USA was re registered to the ISO 9001 2000 standard Limited Warranty OHAUS products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period During the war
3. humidity non condensing Height above sea level Up to 4000 m Operability assured at ambient temperatures between 0 C and 40 C Power AC Adapter 12VDC 420mA output 4 batteries or rechargeable battery Protection dust and water Pollution degree 2 Installation category Class Ill EMC See Declaration of Conformity Navigator 6 1 Specifications EN 9 Typical specifications Stabilization Time lt 1 seconds Tare range To capacity by subtraction Application Modes weigh percent parts count check weigh accumulate hold Weighing Units Non Approved ct g kg grn lb oz lb oz ozt N dwt tael 3 tola tical M models g kg ct N models g kg ct Ib oz ozt dwt grn AC Power AC Adapter supplied 12 VDC or 12VAC 420 mA Battery Power NV 4 AA LR6 batteries not supplied NVL NVT 4 C LR14 batteries not supplied or rechargeable battery option Calibration Digital with external weight LCD Display 6 digit 7 segment LCD with white LED backlight LED Display 6 digit 7 segment LED Display Size 20 mm 0 78 digits Keypad 4 button overlay plus two programmable IR sensors Ingress Protection IP43 NVT and NVL models Pan Size W x D NV 190 mmx 138mm NV212 120mm NVL 194 mmx 203mm NVT 230 mm x 174 mm Net Weight NV 0 9kg 2 2 lob NVL 1 5 kg 3 3lb NVT 1 5 kg 3 3 Ib Shipping Weight INV 1 4kg 3 1lb NVL 2 3kg 5 1 lb NVT 2 3 kg
4. the IR sensor to act the same as the related button Display activates the display if Display Auto is set O e ff disables the sensor Navigator EN 7 4 4 Mode Menu This sub menu activates modes so they will be available for use with the Mode button Weigh mode is always active e Parts Count Count on off Set on for the mode to be active e Percent PEr ent on off Set on for the mode to be active e Hold Haid on off Set on for the mode to be active e Accumulate AECUP on off Set on for the mode to be active e Check Weigh EHELF on off Set on for the mode to be active 4 5 Units Menu This sub menu activates units so they will be accessible with the Units button The units in the menu must be turned on to be active The ounce oz and pound ounce lb 0z units include the option of decimal dEc or fractional Fr Ae readouts Due to different agency requirements the grain unit has two icon display options gr or grn Note Available units and modes vary by model and local regulations 4 6 Sealing access to balance settings The Menu Lock switch limits changes to the Cal Setup Mode and Unit menus The switch in type approved models may set some balance settings as required by the approval agency The switch may be secured using paper seals wire seals or plastic ties Locked Unlocked 5 MAINTENANCE 5 1 Troubleshooting The following table lists common problems and possible c
5. 6000 16000g 5g Il 10kg 10kg 15kg Note 1 M EC Type approved N NTEP and Measurement Canada approved 1 Factory installed rechargeable battery option 2 LED display 3 LED display with factory installed rechargeable battery option Example NVT3200M 3 Note 2 6 2 Drawings 204 mm 8 in 212 mm 8 4 in 58 mm 2 3 in 204 mm 8 in 282 mm 11 1 in 74 mm 2 9 in 240 mm 9 5 in 250 mm 9 8 in 74 mm 2 9 in Navigator EN 11 6 3 Compliance Compliance to the following standards is indicated by the corresponding mark on the product Mark Standard S This product conforms to the EMC directive 2004 108 EC the Low Voltage Directive 2006 95 EC and the Non automatic Weighing Instrument Directive 2009 23 EC The Declaration of Conformity is available online at www OHAUS com AS NZS4251 1 Emission AS NZS4252 1 Immunity Important notice for verified weighing instruments Weighing Instruments verified at the place of manufacture bear one of the preceding M marks on the packing label and the green M metrology sticker on the descriptive data plate They may be put into service immediately M HMH Weighing Instruments to be verified in two stages have no green M metrology on the descriptive data plate and bear one of the preceding identification marks on the packing label The second stage of the initial verification must be carried out by an authorized and certified service org
6. Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 F OHAUS Navigator Balances Instruction Manual Navigator EN 1 1 INTRODUCTION This manual contains installation operation and maintenance instructions for the Navigator Series Please read the manual completely before using the balance 1 1 Safety Precautions Please follow these safety precautions Verify that the AC Adapter input voltage matches the local AC power supply Only use the balance in dry locations Do not operate the balance in hostile environments Do not drop loads on the platform Service should be performed only by authorized personnel 1 2 Controls Exit ee p Cl Cl pa 4 a CY rin i rin Pd b mean 3 ak i Su NN J OHAUS wt K lt Li iogan 6 an at Under NAVIGATOR Print Function Tare Units Mode Ment Yes No Back Exit Short Press when on Sets display to zero when off Turns balance on Long Press when on Turns the balance off Short Press in Menu Selects accepts displayed setting Short Press See Interface Manual for operation description Long Press Toggles through active units Short Press in Menu Toggles through available settings Function Short Press Selects function setting Mode Long Press Selects active Mode Back Short Press in Menu returns to previous settings Tare Short P
7. anization established within the European Community or by the National Notified Body The first stage of the initial verification has been carried out at the manufacturers work It comprises all tests according to the adopted European standard EN 45501 1992 paragraph 8 2 2 If national regulations limit the validity period of the verification the user of the weighing instrument must strictly observe the re verification period and inform the respective weights and measures authorities Disposal In conformance with the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE this device may not be disposed of in domestic waste This also applies to countries outside the EU per their specific requirements The Batteries Directive 2006 66 EC introduces new requirements from September 2008 on removability of batteries from waste equipment in EU Member States To comply with this Directive this device has been designed for safe removal of the batteries at end of life by a waste treatment facility Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment If you have any questions please contact the responsible authority or the distributor from which you purchased this device Should this device be passed on to other parties for private or professional use the content of this regulation must also be related Disposal instructions in
8. auses and remedies If the problem persists contact OHAUS or your authorized dealer Symptom Possible Cause Remedy No power to balance Verify connections and voltage Improper calibration Perform calibration Unstable environment Move balance to suitable location eannopeaiiraic Unstable environment Move the balance to suitable location Incorrect calibration weight Use correct calibration weight EN 8 Navigator rr 8 3 tond Overoad capi9e aa 5 2 Service Information If the troubleshooting section does not resolve or describe your problem contact your authorized OHAUS service agent For service assistance or technical support in the United States call toll free 1 800 526 0659 between 8 00 AM and 5 00 PM EST An OHAUS product service specialist will be available to provide assistance Outside the USA please visit our web site www ohaus com to locate the OHAUS office nearest you 5 3 Accessories Rechargeable Battery Kit 83032106 NVL NVT RS232 Interface Kit 83032107 NV NVL NVT USB Interface Kit 83032108 NV NVL NVT Ethernet Interface Kit 83032109 NV NVL NVT In Use Cover Kit 83032223 NV 83032222 NVL 83032221 NVT Carrying Case Kit 83032226 NV 83032225 NVL 83032224 NVT Printers and Cables Contact OHAUS 6 TECHNICAL DATA The technical data is valid under the following ambient conditions Ambient temperature 10 C to 40 C Approved models M 0 C to 40 C Relative humidity 20 to 85 relative
9. ay shows the calibration weight value Place the specified calibration mass on the pan blinks while the reading is stored The balance returns to the previous application mode and is ready for use Required Span Calibration Mass sold separately Capacity Capacity Capacity 210g 1600g 2100g 1kg 2b 6400g 10kg 5kg 10lb 310g 510g 300g 3100g 4100g 2kg 5lb 16kg 20kg 10kg 201b 100g 500g tIb 5100g 3kg 5lb_ P Pound masses are used when calibrating in the Ib unit EN 4 Navigator 3 OPERATION All modes except for weighing must be activated in the User Menu before they are available see Section 4 3 1 Weigh Mode 1 Press and hold Mode until UE 16H Weigh is displayed 2 If required place an empty container on the pan and press Tare 3 Add material to the container The display shows the weight of the material 3 2 Parts Counting Mode This mode counts large numbers of items based on the weight of a reference count 1 Place an empty container on the pan and press Tare 2 Press and hold Mode until Count Count is displayed Et r RPU Clear Average Piece Weight will then display 3 Press No to use the stored APW Proceed to step 6 4 Press Yes to establish an APW The balance will then display the stored sample size i e Put iG Press No or Back to toggle the choices 5 10 20 50 or 100 5 Put the indicated number of pieces on the pan then press Yes to calculate the APW The d
10. e held weight value 3 5 Accumulation Mode This mode allows the user to store the total of a series of weight measurements With an Interface Option the component weights and the total weight can be transmitted 1 Press and hold Mode until AECUF Accumulate is displayed fir Ace clear accumulate will then display 2 Press Yes to clear the stored value or No to continue adding to the stored total 3 If required place an empty container on the pan and press Tare 4 Add first item its weight is displayed Press Function to store the weight the Accum indicator will flash and the display will show the total weight 5 Remove the first item and add the next item The balance will display its weight Press Function to store its weight The Accum indicator will flash and the new total weight will be displayed 6 Repeat step 5 for all of the items to be added Note While the display indicates zero press Function to view the current total number of samples and the total weight 7 To clear the stored total press and hold Mode until ACCUP is displayed Press Yes when Cir Aec is displayed 3 6 Checkweigh Mode This mode sets low and high weight limits for portion control processes 1 Press and hold Mode until CHEE Check is displayed Et r r EF clear references will then display 2 Press No to use the stored reference weight limits and proceed to step 5 Note Press Function to view the low and high reference weig
11. er the balance when battery power is not needed oh he Input Jack Battery Cover Connect the AC Adapter plug to the Connect AC Adapter to the input jack proper AC supply Battery installation without optional internal battery Remove battery cover and install 4 batteries using the polarity indications as shown in the compartment Optional rechargeable battery NVL and NVT models only Balances with the optional rechargeable battery will need to be charged for 12 hours before the balance can be operated on battery power for the first time The battery is protected from overcharging so the balance can remain connected to the AC power When the battery is fully charged the battery indicator on the display will stop blinking To remove the rechargeable battery option and install C cell batteries reference the Recharging Battery Option instruction manual for step by step instructions as well as disposal instructions Caution Risk of explosion can occur if the rechargeable battery is replaced with the s wrong type or if it is not properly connected 2 5 Initial Calibration When the balance is first installed it should be calibrated to ensure accurate results Press and hold Menu until PERU Menu is displayed When the button is released the display will display A i Press Yes to accept SPAR will then be shown Press Yes again to begin the span calibration E blinks while zero reading is stored Next the displ
12. ht limits 3 Press Yes to establish new reference values The balance will then display SEt Lo Press Yes to view the Low limit value Press Yes to accept or No to edit the Low limit value The stored value then displays with the first digit highlighted 09 088 kg Repeatedly press No until the desired number appears Press Yes to accept and highlight the next digit Repeat until all the digits are correct Press Yes to accept the low limit value SEt H will be displayed 4 Repeat the same procedure to accept or edit the high value 5 Place sample material on the Pan The Accept indicator will now show that the sample weight is within the acceptable range 6 To clear the stored reference values press and hold Mode until CHEE is displayed Press Yes when Ctir r EF is displayed EN 6 Navigator 4 SETTINGS The User Menu allows the customizing of balance settings Note Additional Sub Menus may be available if Interface Options are installed See Interface User Manual for the additional setting information 4 1 Menu Navigation User Menu ct g kg grn lb oz Ib oz Menu Items ozt N dwt thk tsg ttw tola tical End Press and hold Menu until PRENU Menu is displayed When released the first sub menu 4 t Cal will be shown Press Yes to enter the displayed sub menu or press No to advance to the next Selecting a sub menu will display the first menu item Press Yes to vie
13. isplay shows the piece count Note Press Function to view the current APW 6 Add additional pieces until the desired count is reached 7 To clear the stored APW press and hold Mode until fount is displayed Press Yes when Cir APu is displayed 3 3 Percent Mode This mode measures the weight of a sample as a percentage of a reference weight 1 Place an empty container on the pan and press Tare Press and hold Mode until PEr ent is displayed Et r r EF clear reference will then display Press No to use the stored reference weight and proceed to step 6 Press Yes to establish a new reference Balance will now display Put r EF Add the desired reference material to the container Press Yes to store the reference weight The display shows 100 Note Press Function to view the current reference weight 6 Replace the reference material with the sample material The display shows the percentage of the sample compared to reference weight 7 To clear the stored reference press and hold Mode until PEr cnt is displayed Press Yes when Cir r EF is displayed o1 amp GW PP Navigator EN 5 3 4 Display Hold Mode This mode holds the highest stable weight value for easy reference 1 Press and hold Mode until Hot d is displayed 2 Place samples to be weighed on the pan When the balance detects the highest stable weight the Hold Indicator will blink and the displayed weight will not change 3 Press Function to release th
14. ranty period OHAUS will repair or at its option replace any component s that proves to be defective at no charge provided that the product is returned freight prepaid to OHAUS This warranty does not apply if the product has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than OHAUS In lieu of a properly returned warranty registration card the warranty period shall begin on the date of shipment to the authorized dealer No other express or implied warranty is given by OHAUS Corporation OHAUS Corporation shall not be liable for any consequential damages As warranty legislation differs from state to state and country to country please contact OHAUS or your local OHAUS dealer for further details Product Registration Protect your investment Register your product with your local OHAUS dealer Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com
15. ress Enter clear a Tare value Menu Long Press Enters User Menu Short Press in Menu Quickly exit User Menu IR Sensor Left IR Sensors can be programmed to act as touchless buttons See the IR Sensor Right User Menu section 4 3 for the available settings The IR Sensors can be activated by a hand or other object that is placed about 12mm 12 inch above the sensor locations The sensor activation distance will vary based on the reflective nature of the object If unwanted activations occur due to unique situations the sensors can be turned off EN 2 Navigator i So TIN ate oe DOI O Oas Ofa d EEUE i N de OH HE k OhOO 4 O O V Under fenu Mode NAVIGATOR eis Function Tare Mode 3 Menu p4 Back Exit Approved models shown with LCD display 2 INSTALLATION 2 1 Package Contents e Balance e Power Adapter e Warranty Card e Pan e Instruction Manual 2 2 Transportation Lock The Transportation Lock is located under the balance Rotate the pointer to the unlocked position Locked Position Pointer Unlocked Position Note No shipping lock on Approved models 2 3 Location Use the balance on a firm steady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes Adjust the leveling feet so the bubble is centered in the circle YES NO Navigator EN 3 2 4 Power The AC Adapter is used to pow
16. w the menu item setting or press No to move to the next menu item When viewing the setting press Yes to accept the setting or press No to change the setting When End is displayed press Yes to return to the sub menu selections or No to return to the first item in the current menu 4 2 Cal Sub Menu e Span SPAR yes no Initiates a span calibration procedure zero and span A span calibration is important when initially setting up the balance e Lin t n yes no Initiates a linearity calibration procedure zero mid point and span 4 3 Setup Sub Menu The backlit LCD and red LED displays will have different menu items or settings based on the functionality e Auto Off R OFF on off When Auto Off is set to on the balance will turn off automatically after 5 minutes of inactivity Auto off is used to save battery power e Display d SPLY on auto dim LED off LCD This setting controls the LCD backlight or the LED digits constant on automatic turn off after 5 seconds of balance inactivity dimming of the LED after 60 seconds of balance inactivity or LCD backlight always off e Bright br Sht hi mid low This setting controls the brightness of the LED display LCD models will not see this menu item e R Sensor Left tr LEFE Right ir She Off Tare Function Print Zero Display These settings determine the role of the IR Sensors Zero Print Function or Tare allows