Home
RC-200 Owner`s Manual
Contents
1. the Remote Control is turned ON all the circuitry inside the inverter becomes fully alive and the AC output is made available In this condition even when no load is being supplied or if a load is connected but has been switched OFF the inverter draws a small amount of current from the batteries to keep the circuitry alive and is ready to deliver the required power on demand This is called the idle current or the no load current draw When the inverter is turned OFF using this Remote Control some control circuitry is still alive in the inverter and will require very small current draw Hence when the load is not required to be operated turn OFF the ON OFF Switch on the inverter to prevent unnecessary current drain from the battery SECTION 6 SPECIFICATIONS MODEL NUMBERS OF PST 1500 12 PST 1500 24 COMPATIBLE INVERTERS PST 2000 12 PST 2000 24 CABLE SET Over connections Length 5 metres 16 5 OPERATING TEMPERATURE RANGE 0 to 40 C 32 F to 104 F DIMENSIONS L X W X D 110 x 65 x 24 7 mm 4 33 x 2 56 x 0 97 in Weight Without cable with cable 85 gm 256 gm 0 04 Ib 0 12 Ib NOTE Specifications are subject to change without notice 6 SAMLEX AMERICA INC SECTION 7 WARRANTY 2 YEAR LIMITED WARRANTY RC 200 Remote Control manufactured by Samlex America Inc the Warrantor is warranted to be free from defects in workmanship and materials under normal use and service The warr
2. CD Light 3 9 LCD Data 2 10 LCD Ground 1 1 As shown in Figure 2 2 Mirror image of Remote Control Jack due to crossed over rolled over connection of conductors SAMLEX AMERICA INC 5 SECTION 4 INSTALLATION Please refer to Fig 1 The Remote Control can be flush mounted on a wall or a panel by making a suitable cut out to accommodate the projection in the back Connect one end of the cable set to the RJ 50 Modular Jack 7 at the back and the Remote and the other end to the RJ 50 Modular Jack on the inverter Ensure that the connection is firm and the tab on the plug securely locks in the jack SECTION 5 OPERATION Please refer to Fig 1 Please also refer to the Owner s Manual of the inverter for associated details NOTE For the Remote Control to operate the ON OFF Switch on the inverter is required to be in ON condition to activate the control circuitry for the Remote Control Switch on the inverter first with the help of the Power ON OFF Switch on the inverter The output of the inverter can now be switched OFF ON by pressing the ON OFF Push Button 1 See under headings LCD Display and LED Display above for information on the operating conditions Read the Owner s Manual of the inverter for troubleshooting of abnormal conditions indicated by the LEDs No Load Current Draw As stated above the ON OFF Switch on the inverter is required to be in ON condition for the Remote to operate When the ON OFF switch on
3. anty period is 2 years for the United States and Canada and is in effect from the date of purchase by the user the Purchaser Warranty outside of the United States and Canada is limited to 6 months For a warranty claim the Purchaser should contact the place of purchase to obtain a Return Authorization Number The defective part or unit should be returned at the Purchaser s expense to the authorized location A written statement describing the nature of the defect the date of purchase the place of purchase and the Purchaser s name address and telephone number should also be included If upon the Warrantor s examination the defect proves to be the result of defective material or workmanship the equipment will be repaired or replaced at the Warrantor s option without charge and returned to the Purchaser at the Warrantor s expense Contiguous US and Canada only No refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of the equipment including exposure to excessive heat salt or fresh water spray or water immersion No other express warran
4. ghted when the inverter is in ON condition When the inverter is in OFF condition this LED will not be lighted This LED shows that DC input is available to the inverter and that the input section of the inverter is operating normally Red LED 4 marked OVER LOAD When lighted it indicates that the AC output of the inverter has been shut down due to over load Red LED 5 marked OVER TEMP When lighted it indicates that the AC output of the inverter has been shut down due to over temperature Pinout of RJ 50 Modular Jack The pinout of the RJ 50 Modular Jack 7 at the back of the unit is given at Fig 2 below kcn Toggle Avec Ground for LEDs Vee LED Power ON LED Over Temp LED Over Load LCD Light LCD Data LCD Ground 12345678910 Soenavawne Fig 2 Remote Control RC 200 Pinout of Modular Jack RJ 50 The standard numbering system of the pins of a Modular Jack when looking into the Jack is from left to right As the conductors of the cable are cross connected rolled over the pinouts at the Modular Jack in the inverter will be a mirror image of the pinout of the Modular Jack in the Remote Control as shown in table below Pinout of Modular Jack on Pinout of Modular the Remote Control Signal Jack on the inverter 1 Toggle 10 2 Avcc 9 3 Ground for LEDs 8 4 Vcc 7 5 LED POWER ON 6 6 LED OVER TEMP 5 7 LED OVER LOAD 4 8 L
5. output current in A Active AC output power in Watts W Apparent Output AC Power in Volt SAMLEX AMERICA INC 3 Amps VA and Power Factor PF will not be displayed will be displayed as 0 This is necessary because at power output lt 2 5W the noise on the output side may be comparable to the low value of the load and the logic may not be able to differentiate noise from load and hence may display wrong values for these parameters Power Saving Sleep Mode in the LCD Display To save power the LCD display will remain ON for 3 minutes from the time the Display Push Button 2 is pressed and will then switch OFF into Sleep Mode To wake up press the Display Push Button 2 amp samlexpower o o DISPLAY 9 A gt Hz gt W gt VA PF EE o e 8 ety gi EA a mooeLrc20 5 6 110 Pure Sine Wave E aan Front View Overall Depth 25 5 n R2 98 i 80 gt i Back View LEGEND Power ON OFF Push Button TEF Push Button to Change Display Screen NOTE All dimensions in mm LCD Screen LED Overload LED Over Temp LED Power RJ 50 Modular Jack NOW awn Fig 1 Remote Control RC 200 Layout and Dimensional Drawing 4 SAMLEX AMERICA INC LED Display The following LED displays are available Green LED 6 marked POWER This LED will be li
6. samlexpower Remote Owner s Please read this manual BEFORE Control for Manual operating your Inverter RC 200 Remote Control RC 200 OWNER S MANUAL SECTION 1 Safety denem A dnetee tenn 3 SECTION 2 Descipion T persans e te aster stee ete eect eee 3 SECTION 3 Layout of Controls Indications amp Dimensional Drawings cecccccseceseseeeeseseeeeseseesestecescaeeeetaeeeees 3 SECTION 4 Installation copse erir a 6 SECTION 5 o 1 614 0 RNC ceererrerre meer seerr N ere peeret ere 6 SECTION 6 SOeCIICAHONS 25 2 058 2c tedden ki eles 6 SECTION 7 Warranty ccizniscaijecs tetova pests ante E E EE i EE 7 DETAILED PRODUCT INFORMATION For a complete user manual including specifications application notes installation instructions trouble shooting and more please visit the web page for this product on samlexamerica com Product page can be found using the search by model field 2 SAMLEX AMERICA INC SECTION 1 SAFETY Before using this Remote Control please follow the Safety Instructions given in the Owner s Manual for the inverter SECTION 2 DESCRIPTION RC 200 is a wired Remote Control that is compatible with the following series of Inverters PST 1500 12 PST 1500 24 and PST 2000 12 PST 2000 24 It is used to switch ON and switch OFF the inverter from a remote location It also displays the operational status using LCD display and colored LEDs It is provided with 5 Metres 16 5 Fee
7. t of connecting cable set with RJ 50 Modular Plugs 10P10C The conductors of the cable set have crossed over rolled over connections on the two RJ 50 plugs SECTION 3 LAYOUT OF CONTROLS INDICATIONS amp DIMENSIONAL DRAWING Fig 1 page 4 shows the layout of controls and indications and dimensional drawing ON OFF Control ON OFF Push Button 1 is used to switch ON and switch OFF the inverter Every time the ON OFF Push Button is pressed a beep will be heard LCD Display LCD screen 3 is used to display the following 6 output parameters in a se quential loop as given below The screen changes to show the successive parameter in a sequential manner every time the Display Push Button 2 is pressed Sequence is Screen1 2 3 4 5 6 1 2 3 1 AC output voltage in Volts V 2 AC output current in Amps A 3 AC output frequency in Hertz Hz 4 Active AC output power in Watts W The display is limited to a range of 2 5W 3500W 5 Apparent Output Power in Volt Amps VA 6 Power Factor PF When the inverter is switched ON using the ON OFF Push Button 1 the LCD screen displays information as follows It takes 2 to 6 sec for booting initialization During this time all the above 6 parameters will be displayed as 0 If the load is gt 2 5W all the above 6 parameters will be available for display after end of booting initialization period If the AC output power is less than 2 5W parameters AC
8. ty is hereby given and there are no warranties which extend beyond those described herein This warranty is expressly in lieu of any other expressed or implied warranties including any implied warranty of merchantability fitness for the ordinary purposes for which such goods are used or fitness for a particular purpose or any other obligations on the part of the Warrantor or its employees and representatives There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any persons or damage to person or persons or damage to property or loss of income or profit or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment including any possible failure of malfunction of the equipment or part thereof The Warrantor assumes no liability for incidental or consequential damages of any kind Samlex America Inc the Warrantor www samlexamerica com SAMLEX AMERICA INC 7 Contact Information Toll Free Numbers Ph 800 561 5885 Fax 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders samlexamerica com A samlexamerica
Download Pdf Manuals
Related Search
Related Contents
三菱電機株式会社 中津川製作所 L80 Tape Library Manuale dell`utente 〈取扱説明書〉 A B C - 株式会社リッチェル ペット用品 [ 富士ドライケム プラズマフィルター PF ] ≫PDF Siig eSATA II ExpressCard RAID Tahiti X - AVSIM Online User manual Sony DCR-TRV730 Camcorder User Manual VM0808 Copyright © All rights reserved.
Failed to retrieve file