Home

Expander 8 dry contacts

image

Contents

1. a ie eer een 7 3 Relay BOX S speciricationi uch 8 1 Introduction 1 1 What is RMS U RB 8 The Relav Box 8 allows for remote use of electrical devices over the Internet It provides eight high power SPDT 5V relays in one array It includes Metal Oxide Varistors MOVs and Snubber circuits to protect the open contact of the relays from high voltage spikes or noise transients It monitors the power load and accepts a control signal which is sent from the unit The RMS U RB 8 is designed to work with the RAMOS Ultra only 1 2 Where to use this RMS U RB 8 e Power Switch e On Off Control e Activate Alarms e Process Control e Energy Management Systems www conteg com All rights reserved CONTEG 2012 2 Installing and configuring Relay Box 8 2 1 Plug it into intelligent sensor port Plug the sensor into one of the RJ45 ports on the rear panel of the unit If you are going to use more than 1 Relay Box 8 unit then a 7 5 volt 3A external power supply is required 2 2 Log in Type the IP address of the RAMOS Ultra unit default 192 168 0 100 into your web browser Log in as the administrator using your administrator password default public You will then be taken to the summary page 2 3 Goto Sensors tab From the summary or main page you need to select the Sensors tab The layout of the next page will vary depending on your unit so please refer to your unit s manual 2 4 Setting You sho
2. Current Windows New Windows Filter Status Enable Disable Relay Control Mode Manual Control Notification Control Time Control Thermostat Toggle 5 Second s Test Relay Toggle Test Relay Control Mode Configuration examples include a Manual Control allows you to manually control each of the eight relays using the Relay Control option You will be able control the cycle of the relay in an on off on or an off on off cycle You can also set the Cycle Time here in seconds and manually test each relay using the Test Relay Cycle button b ee Notification Control allows you to link any of the relays to an action The actions can be selected from the Action drop down menu after clicking on To set notification controlled relay click here The following actions can be chosen Turn on until sensor normal turn off until sensor normal cycle the relay turn on until acknowledged turn off until acknowledged You can also turn the Sensor Normal Relay State to on or off and test each relay using the Test Relay Cycle button c Time Control Displays a calendar to setup what days and times you want or do not want each relay to be active d Thermostat Option to select a thermostat for ports 1 through 8 which will control the relay www conteg com All rights reserved CONTEG 2012 3 Relay Box 8 specification Power Supply 7 5VDC 3A RMS U PW is required Relay contacts r
3. Normal When the relay I is online and its Normal State Field is OFF then the status is Critical If at any time communications with the Relay Box 8 are lost the status is changed to Sensor Error Sensor currently Click to switch online activate this relay port or offline deactivate the relay port Note if you change the relay output to offline it will no longer be displayed on the web interface In order to reactivate it you have to toggle the relay back to online Description of Status When Relay On This field is the custom description which will be displayed in the relay status field when the relay is on The same text is listed as one of the relay actions used to turn on the relay Examples for this field are Open Door Turn Pump On Turn Light On etc This applies to all eight relays in the Relay Box 8 Description of Status When Relay Off This field is the custom description which will be displayed in the relay status field when the relay is off The same text is listed as one of the relay actions used to turn off the relay Examples for this field are Close Door Turn Pump Off Turn Light Off etc This applies to all eight relays in the Relay Box 8 www conteg com All rights reserved CONTEG 2012 2 6 Advanced Setting details Relay 8 2 Normal Settings Advanced Settings Enable Graph On Off Popup Windows on Sensor Name Sensors URL Open linkin
4. Online Click on a port to display or configure its settings nn Temperature Sensors on Port 8 Relay Port 8 1 The each line present z Relav Port 8 3 one relav and with click ern e Relay Port 8 5 you will open a setting Relay Port 8 6 Relay Port 8 7 Relay Port 8 8 Click on a relay to open setting shown below 1 2 3 4 5 6 7 8 Auto Sense __ Auto Sense __MAutosense_ __ Auto Sense _ I Auto Sense __ E Auto Sense E Auto Sense __MAutosense L I Auto Sense 7 E A Online Temperature Relay 8 2 Normal Settings Advanced Settings Sensor Name elay Port 8 2 Status Off Sensor Currently E Online _ Description of Status When Relay On On Description of Status When Relay off Off Each relay setting is entered on this page including the advanced settings www conteg com All rights reserved CONTEG 2012 2 5 Normal Setting details l Sensor Name Relay Port 8 2 Advanced Settings Status Off Sensor Currently E Online _ Description of Status When Relay On On Description of Status When Relay Off off Sensor Name Here you can enter a new name for the relay output This name will be displayed on the Summary page Status Shows the current state of the relay output When the relay box is offline the relay status is No Status When the relay is online and its Normal State field is ON then the status is
5. RMS U RB 8 Relay box 8 User Manual Wee un be ok tl Gie Version 1 1 28 05 2014 www conteg com 2013 CONTEG spol s r o All rights reserved No part of this publication may be used reproduced photocopied transmitted or stored in any retrieval system of any nature without the written permission of the copyright owner Although this manual was prepared and checked with the best care CONTEG spol s r o cannot accept any liability for omissions or errors in this publication Due to the continuous development and progress CONTEG spol s r o also reserves the right to change details and technical specifications of the products described in this manual Such changes along with eventual errors or printing errata shall not constitute grounds for compensation www conteg com All rights reserved CONTEG 2012 Content i 11 dere 310 Tl ON apse aca eat tuna cas ona R E squnn secede enaqs E R 3 KE VRR RMS URD sects ee ee tec ee 3 1 2 Where to use this RMS UFRB 32 onen 3 2 Installing and configuring the Relay BOX 8 ccccccssccccssseccceseccceenecceesescceseeseceseeaeceeeeusecessuaeceseuneceteeges 4 2 1 Plug it ON intelligent sensor POMt cc eecccesecccsecceeseecceseceeencecaenceceueceseeceeeeeesencesseecessnecessneceneness 4 2 2 On ee werk 4 2 9 GOTOR g S10 BA De ee ee ee ee ee ee A ee ee 4 24 SEK ee ee re A 4 25 Normal settifie details ian tai ee ka i a a ee 6 26 Aavgneea settima
6. ated at 15 A 220 VAC 25VDC with Resistive Load 8 A 220 VAC 25VDC with Inductive Load P F 0 4 L R 7 mS Contact Material AgCdO Max Operating Voltage 380 VAC 125 VDC Max Switching Capacity 4 000 VA 480W with Resistive Load 2 000 VA 240W with Inductive Load P F 0 4 Power Consumption Typically 2 5 W 0 5A Communications cable RJ 45 jack to sensor using UTP Cat 5 wire Sensor type Open Close contact switches 8 The unit auto detects the presence of Relay Box 8 Full autosense including disconnected alarm Metal Oxide Varistors MOVs and Snubber circuit protect the open contacts of the relays from high voltage spike LEDs across the front panel indicate the status of each Relay and the Power Supply Dimensions 216 W x 138 H x 46 D mm Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C 8 7 6 5 4 3 2 1 ere ee aaa r www conteg com All rights reserved CONTEG 2012
7. uld now be able to configure the settings of your Relay Box including the sensor name the descriptions of each relay status the relay control mode etc The first screen shot below shows our 8 Port Sensor Control Relay on port 8 of our unit en G GCONTFEG RAMS to complete your networi ULTRA Location System Location Current System Time 21 10 2013 09 39 05 Summary Map Sound Log Sensors Notification Access Control Settings Applications Help Sensor Settings Sensors Menu Host Name Main Module Sensor Ports Sound Detector 4 Power Meter Virtual Sensors 1 2 3 4 5 6 rd This page shows the sensor ports and their Status GO e amp e e e respective status and state Online Click on a port to display or configure its ig m Temperature Airflow NIC NIC NIC NIC NIC Move cursor over the intelligent port where is connected the Relay Box 8 You will be able to see all relays and select each for individual settings including advanced settings www conteg com All rights reserved CONTEG 2012 w X CONTEG RAMOS p Location System Location Current System Time 21 10 2013 09 43 41 Summary Map Sound Log Sensors Notification Access Control Settings Applications Help Sensor Settings Sensors Menu aa Host Name jain Module Expansion Boards Save Reset __ Sound Detector Power Meter Virtual Sensors Help Auto Sense This page shows the sensor ports and their Status respective status and state