Home

FX100

image

Contents

1. switched on off for each channel Burnout upscale downscale selectable Burnout condition Normal less than 2 kQ Burnout more than 100 kQ Filter function FX103 On off selectable for each channel Time constant selectable from 2 5 and10 seconds FX106 FX112 Moving average on off selectable for each channel moving average cycles 2 to 16 selectable Calculation Differential computation linear scaling square root Display Display unit 5 5 inch TFT color LCD 320 x 240 pixels Waveform span rate FX103 15 30 sec 1 2 5 10 15 20 30 min 1 2 4 10 hours div selectable FX106 FX112 1 2 5 10 15 20 30 min 1 2 4 10 hours div selectable LCD back light saver function Automatically dims if no key is touched for a certain preset time Timer setpoint 1 2 5 10 30 or 60 min Temperature unit C or F selectable Language English French and German selectable Data Saving Function Internal memory Flash memory 1 2M External storage medium Selectable from 1 None 2 3 5 inch floppy disk 2HD 1 44 MB 3 Compact flash memory card 32 to 512 MB Saving method Manual or automatic selectable Measurement data files Display data and event data Data saving period Display data file Linked with the waveform span rate Event file Linked with the specified sampling period Event File sampling period FX103 Selectable from 250 500 ms and 1 2 5 10 30 60 120 300 600 s FX106 FX112 Selectable fr
2. and all key operations are not permitted User name User ID and password are required to enter the operation mode And key lock by password can be set to prevent to change settings GS 04L20A01 00E 1st Edition Oct 10 2003 00 lt lt Contents gt gt lt lt Index gt gt E SPECIFICATIONS OF OPTIONAL FUNCTIONS Alarm Output Relays A1 A2 A3 Outputs Number of outputs 2 4 6 points An alarm signal is output from the rear panel as a relay contact signal Relay contact rating 250 VDC 0 1 A for resistance load 250 VAC 50 60 Hz 3 A Terminal configuration SPDT NO C NC Energized at alarm deenergized at alarm AND OR and hold non hold actions are selectable Serial Communication Interface C2 C3 Allows the host computer to control and make settings for the recorder as well as receive data from the recorder Connection EIA RS 232 C2 or RS 422 A 485 C3 Protocols YOKOGAWA private protocol Modbus protocol Synchronization method Start stop asynchronous transmission Connection method RS 422 A 485 4 wire half duplex multi drop connection 1 N where N 1 to 32 Transmission speed 1200 2400 4800 9600 19200 or 38400 bps Data length 7 or 8 bits Stop bit 1 bit Parity Odd even or none Communication distance RS 422 A 485 Up to 1 2 km Communication mode ASCII for input output for control and setting ASCII or binary for output of measured data Modbus communicati
3. lt lt Contents gt gt lt lt Index gt gt General FX100 Specifications GS 04L20A01 00E E OVERVIEW FX100 displays real time measurement data on TFT color LCD and saves the data in external media 3 5 FD or Flash memory card or FTP server It comes with a three six or twelve channel As the input signal a DC voltage thermocouple resistance temperature detector or contact signal can be set to each channel NKOLNOLETAWANK 2 GROUP 1 Zy espeennin 216 Sep Bd 2083 15 00 49 RTE E Standard Specifications Construction Dimensions 144 W x 144 H x 234 D mm S Weight FX1xx 0 2 2 kg Z deer e A A am a mis C FX1xx 1 2 5 kg salina L FX1xx 4 2 3 kg Front panel Water and dust proof based on IEC529 IP65 Inputs Input Ranges and Measuring Ranges Number of inputs Input Type Input Range Measuring Range FX103 3 channels 20 00 to 20 00 mV FX106 6 channels Perey FX112 12 channels Measurement interval 200 mV 200 0 to 200 0 mV 2 000 to 2 000 V FX103 250 ms Pav 6v 6 000 to 6 000 V FX106 FX112 1s 2s Inputs VDC DC voltage TC thermocouple RTD eer arse 50 00 to 50 00 V DCV 2V 6V resistance temperature detector DI digital 0 0 to 1760 0 C 32 to 3200 0 F 0 0 to 1760 0 C 32 to 3200 0 F 0 0 to 1820 0 C 32 to 3308 0 F 200 0 to 1370 0 C 328 to 2498 0 F 200 0 to 800 0 C 328 0 to 1472 0 F 200 0 to 1100 0 C 32
4. of isolated input type N2 can be specified only for FX106 and FX112 A B b legs of FX103 is isolated as standard Pt1000 input N3 Measuring ranges measurement accuracy and resolution of digital display See table of Input and standard performance Pulse input mathematic function PM1 Number of inputs 3 points 8 points are available in case of using remote inputs Max sampling pulse period Max 100 Hz Minimum pulse length 5 ms Allowed input voltage 30 VDC Pulse measuring accuracy 1pulse for instantaneous mode Measuring mode Instantaneous mode setting Pulse count during measuring period Summation mode setting Pulse count summation by mathematical function TLOG SUM Remote Control R1 Number of remote inputs 8 points This option allows the following eight functions to be controlled remotely by a contact input e Start stop of memory level e Trigger for event file trigger 250 ms or longer e Time adjustment adjusting the time to a preset time upon contact signal trigger 250 ms or longer e Start stop of computation level e Reset of computation data trigger 250 ms or longer e Manual data sample trigger 250 ms or longer e Message display Up to 8 different messages can be set trigger 250 ms or longer e Load of setting parameters Up to 3 settings can be set trigger and 250 ms or longer except for non media model e Alarm acknowledgement trigger 250 ms or longer e S
5. 8 0 to 2012 0 F 1a 200 0 to 400 0 C 328 0 to 752 0 F 4 4 Option 6 input for event recording DCA DC current with external shunt resistor attached 0 0 to 1300 0 C 32 to 2372 0 F 0 0 to 2315 0 C 328 0 to 4199 0 F 200 0 to 900 0 C 328 0 to 1652 0 F 200 0 to 400 0 C 328 0 to 752 0 F 0 0 to 2400 0 C 32 to 4352 0 F 200 0 to 600 0 C 328 0 to 1112 0 F RTD 5 200 0 to 550 0 C 328 0 to 1022 0 F 200 0 to 600 0 C 328 0 to 1112 0 F OFF Less than 2 4 V ON More than 2 4 V oo Contact Input ON OFF 1 R S B K E J T N IEC584 1 1995 DIN IEC584 JIS C1602 1995 2 W W 5 Re W 26 Re Hoskins Mfg Co ASTM E988 3 L Fe CuNi DIN43710 U Cu CuNi DIN43710 4 Pt100 JIS C1604 1997 IEC751 1995 DIN IEC751 1996 JPt100 JIS C1604 1989 JIS C1606 1989 Measuring current i 1 mA B WRe W 5 Re W 25 Re Hoskins Mfg Co 6 Measuring current i 0 16 mA GS 04L20A01 00E YOKOGAWA Copyright Oct 2003 1st Edition Oct 2003 lt lt Contents gt gt lt lt Index gt gt Inputs terminal Clamp terminals clamp connector detachable terminal connector Allowable wire size 0 2 to 2 5 mm2 AWG24 12 Integral time of A D converter 20 ms 50 Hz 16 7 ms 60 Hz 100 ms 50 60 Hz for FX106 and FX112 AUTO selectable automatic selection by detection of power supply frequency from 20 ms 16 7 ms Themoccouple Burnout Burnout upscale downscale function can be
6. andard Performance Measuring and Recording Accuracy The following specifications apply to operation of the recorder under standard operation conditions Temperature 23 2 C Humidity 55 10 RH Power supply voltage 90 to 132 or 180 to 250 VAC Power supply frequency 50 60 Hz 1 Warm up time At least 30 min Other ambient conditions such as vibration should not adversely affect recorder operation Input Type Measurement accuracy digital display Erea 0 1 of rdg 2digits 10 mV 0 1 of rdg 3digits 10 mV DC voltage DCV 20 V ON BV EEI 0 15 of rdg 1 C S However R S 3 7 C at 0 to 100 C 1 5 C at 100 to 300 C B 2 C at 400 to 600 C Accuracy at less than 400 C is not guaranteed Thermocouple 0 15 of rdg 0 7 C TC Excluding the However 0 15 of rdg 1 C at 200 to 100 C reference junction 0 15 of rdg 0 5 C compensation owever 0 1 C accuracy 0 15 of rdg 0 7 C at 200 to 100 C 0 15 ofrdg 0 7 C ssi aD 0 15 of rdg 1 00 ssi 0 15 of rdg 0 50 te rons 0 15 of og 0 7 C at 200 to 100 C Wae Pt1000 0 2 of rdg 0 4 C option All Rights Reserved Copyright 2003 Yokogawa Electric Corporation GS 04L20A01 00E 1st Edition Oct 10 2003 00 lt lt Contents gt gt lt lt Index gt gt Measurement accuracy in case of scaling digits measurement accuracy digits lt scaling span digits measurem
7. ent span digits 2 digits Decimals are rounded off to the next highest number Reference junction compensation INT internal EXT external selectable common for all channels Reference junction compensation accuracy above 0 C in balance of input terminal temperature more than 60 minutes after application of power Types R S B W WRe 1 0 C Types K J E T N L U 0 5 C Note Internal reference junction compensation accuracy for type B is fixed to 0 C Maximum allowable input voltage 10 VDC continuous for less than 200mVDC ranges and TC RTD DI ranges 60 VDC continuous for except above ranges Input resistance Approximately 10 MQ or more for DCV ranges of 200 mVDC or less and TC Approximately 1 MQ for more than 2 VDC ranges Input source resistance VDC TC 2 kQ or less RTD 10 or less per wire The resistance of all three wires must be equal RTD parallel capacity 0 01 uF or less Input bias current 10 nA or less Maximum common mode noise voltage 250 VAC rms 50 60 Hz Maximum noise voltage between channels 250 VAC rms 50 60 Hz Interference between channels 120 dB the input source resistance 500 Q the inputs to other channels 30 V Common mode rejection ratio 120 dB 50 60 Hz 0 1 500 Q imbalance between the minus terminal and ground Normal mode rejection ratio 40 dB 50 60 Hz 0 1 Effects on Operating Conditions Ambient temperature With temperature variation of 10 C F
8. ints 4 o a T A2 Alarm output 4 points 1 A3 Alarm output 6 points 1 RS 232 communication interface including Modbus master slave protocol function 2 3 RS 422 A 485 communication interface including Modbus master slave protocol function 2 3 ic7 Ethernet 10BASE T communication interface FAIL memory end output 4 Mathematical function with report function N2 3 legs isolated RTD Pt1000Q input PM1 Pulse input 3 points control input 5 points including Mathematical function 5 Remote control 8 points 1 A1 A2 A3 cannot be specified together 2 C2 C3 cannot be specified together 3 In case that Modbus master function is utilized M1 or PM1 must be specified 4 If F1 is specified A3 cannot be specified 5 If PM1 is specified each A3 R1 M1 cannot be specified 5 If PM1 is specified A2 and F1 cannot be specified together E Application Software E Optional Accessories Model code Description OS Product Shunt resister Clamp module E Standard Accessories B9968NM 32 MB Product Quantity Mounting brackets Mounting bracket B9900BX 1 For a model with no communication port and no external memory DAQSTANDARD is not attatched 2 Only for FX1xx 4 model All Rights Reserved Copyright 2003 Yokogawa Electric Corporation GS 04L20A01 00E 1st Edition Oct 10 2003 00 lt lt Contents gt gt lt lt Index gt gt E Dimensions Unit m
9. lay output in occurrence of system alarm Manual save mode Relay output before the specified time of overwriting inside memory Selectable from 1 2 5 10 20 50 or 100 hours Auto save mode Relay output when the amount of memory media reaches 90 Relay contact rating 250 VDC 0 1 A for resistance load 250 VAC 50 60 Hz 3 A Mathematical Functions M1 Displays and records computed data assigned to channels Number of computed data assignable channels Up to 12 channels Type of computation General arithmetic operations Four arithmetic operations square root absolute common logarithm exponential power relational operations lt S gt 2 logic operations AND OR NOT XOR Statistical operations Average maximum minimum and summation Long tern rolling average computation is performed on the results of computation Constant Available Up to 30 constants Digital data input via communication Digital data via communication can be used in mathematical expression Up to 12 data Remote status input Remote input status 0 1 can be used in mathematical expression Up to 8 inputs Report functions Report type Hourly daily hourly daily daily weekly and daily monthly Type of computation Average maximum minimum and summation Data format ASCII GS 04L20A01 00E 1st Edition Oct 10 2003 00 lt lt Contents gt gt lt lt Index gt gt 3 legs Isolated RTD Input N2 A B b legs are
10. m approx inch 0 95 2 30 24 1 175 6 89 58 4 9 4 0 37 pie min space for mounting 7 5 0 30 dimension after mounting La RS 232 or RS 422A 485 Ethernet Power Supply Terminal Option Terminal Input Terminal 1 to 12ch All Rights Reserved Copyright 2003 Yokogawa Electric Corporation The TCP IP software used in this product and the document for that TCP IP software are based in part on BSD networking software Release 1 licensed from The Regents of the University of California e Microsoft MS and Windows are registered trademarks of Microsoft Corporation USA e Lotus and 1 2 3 are registered trademark of Lotus Development Corporation e Ethernet is a registered trademark of XEROX Corporation e Modbus is a registered trademark of AEG Schneider e Other company and or product names are registered trade mark of their manufactures GS 04L20A01 00E 1st Edition Oct 10 2003 00
11. napshot trigger 250 ms or longer Load of setting parameters is not be available for non media model All Rights Reserved Copyright 2003 Yokogawa Electric Corporation E APPLICATION SOFTWARE DAQSTANDARD Operating environment OS Microsoft Windows 98 Me NT4 0 2000 XP Basic function packages Configuration software External memory medium configuration of setup and set mode Configuration via communication configuration of setup and set mode without communication configuration ex address Data viewer Numbers of display channels 32 channels for each group at most 30 groups Display function Waveform display digital display circular display list display TLOG display report display etc File connection display Connect data files that are divided by auto save during measuring data or power failure can connect up to total a million Section computation Max value Min value average value effective value p p value Data conversion File conversion to ASCII Lotus 1 2 3 or MS Excel format Print out Print out retrieved data GS 04L20A01 00E 1st Edition Oct 10 2003 00 lt lt Contents gt gt lt lt Index gt gt T E Model Code Model Suttix code Optioncode Description eos o oen oo exo doen oo en o oaae ooo External memory 0 None o a frp sine 4am o Compactnash memory card 82MB Display Language 2 English GermaniFrench oo Option im _ Alarmoutput2po
12. om 1 2 5 10 30 60 120 300 and 600 s All Rights Reserved Copyright 2003 Yokogawa Electric Corporation Alarm Function Number of alarm levels Up to four levels for each channel Alarm types High and low limits differential high and low limits high and low rate of change limits and delay high and low Interval time of rate of change alarms The measurement interval times 1 to 15 The alarm status type is displayed in the digital value display area upon occurrence of an alarm A common alarm indication is also displayed The alarming behavior Non hold or hold type can be selectable for common to all channels Hysteresis On 0 5 of display span off selectable common to all channels and alarm levels Outputs Number of points 2 4 or 6 points optional Relay action Energized deenergized and hold non hold selectable The times of alarm occurrences recoveries alarm types etc are stored in the memory Up to 120 latest alarm events are stored Display Memory Normal Operating Conditions Ambient temperature 0 to 50 C when using FDD 0 to 40 C Ambient humidity 20 to 80 RH at 0 to 40 C 10 to 50 RH at 40 to 50 C Vibration 10 to 60 Hz 0 2 m s or less Shock Not acceptable Magnetic field 400 AT m or less DC and 50 60 Hz Noise Normal mode 50 60 Hz VDC The peak value including the signal must be less than 1 2 times the measuring range TC The peak value including the signal m
13. on Operation mode RTU MASTER or RTU SLAVE Ethernet Communication C7 Connection Ethernet 10BASE T Protocols SMTP HTTP1 0 FTP TCP UDP IP ARP ICMP E mail inform function Kinds of inform The following information can be informed by E mail selectable from inform misinform for each group Alarm inform Informs in occurring alarm canceling alarm System inform Informs in recovering power failure informs the time of recovering informs the rest of time before rewriting on Inside memory manual save mode informs the rest of amount in reaching 90 of media volume and media error auto save mode Schedule time inform Inform the moment value at a certain time or interval Report inform Inform report data in report timeup All Rights Reserved Copyright 2003 Yokogawa Electric Corporation Web server function Displays an image alarm information and moment values of FX screen by browser soft Enables message input from browser screen FTP client function File auto transfer from FX display data file event file report file and snapshot FTP server function Manual transfer of file in the outside media from host computer directory operation information of file elimination and of rest of amount of memory in media Real time monitoring function Real time monitoring FX data by communication Yokogawa private protocol Fail Memory End Output F1 The relay contact output in following cases System Error Re
14. or VDC and TC range 0 1 of rdg 1 digit or less For RTD inputs 0 1 of rdg 2 digits or less Power supply With variation within 90 to 132 V and 180 to 250 VAC 50 60 Hz 1 digit or less With variation of 2 Hz from rated power frequency at 100 VAC 0 1 of rdg 1 digit or less Magnetic field AC 50 60 Hz and DC 400 A m fields 0 1 of rdg 10 digits or less All Rights Reserved Copyright 2003 Yokogawa Electric Corporation Input source resistance With variation of 1 KQ 1 VDC range Ranges of 200 mV or less within 10 uV Ranges of 2 V or greater approximately 0 1 of rdg 2 TC range Within 10 uV 100 uV when the burnout upscale downscale function is switched on 3 RTD range Pt100 With variation of 10 Q per wire resistance of all three wires must be equal 0 1 of rdg 1 digit With maximum difference of 40 mQ between wires Approximately 0 1 C Other Specifications Clock With calendar function year of grace The time can be adjusted by a remote contact with the remote option Summer winter time Summer and wintertime can be set Accuracy of clock 100 ppm excluding a delay of 1 second maximum caused each time the power is turned on Memory backup A built in lithium battery backs up the setup parameters battery life approximately ten years at room temperature Key lock function ON OFF and password can be set Log in function Power on with log out mode
15. ust be less than 1 2 times the measuring thermal electromotive force RTD 100 mV or less Common mode noise voltage 50 60 Hz 250 V AC rms or less for all ranges Maximum noise voltage between channels 50 60 Hz 250 V AC rms or less Warm up time At least 30 min after power on Transport and Storage Conditions Ambient temperature 25 C to 60 C Humidity 5 to 95 RH No condensation is allowed Vibration 10 to 60 Hz 4 9 m s maximum Shock 392 m s maximum while being packed Safety and EMC Standards Safety standards CSA22 2 No 1010 1 UL61010B B CSA NRTL C EN61010 1 EMC standard EN61326 EN55011 Class A EN61000 3 2 EN61000 3 3 GS 04L20A01 00E 1st Edition Oct 10 2003 00 lt lt Contents gt gt lt lt Index gt gt 3 Power Supply Dielectric strength Power supply to ground terminal Rated power supply l ee a Contact Aa ate EAE Allowable power supply voltage range i 90 to 132 or 180 to 264 VAC ee OODD ee ENIN Measuring input terminal to ground terminal 1500 VAC 50 60 Hz 1 min Between measuring input terminals 1000 VAC 50 60 Hz 1 min except for b LOD eave mods Normal Max terminal of RTD input of non isolated Pp y g Between remote control terminal to ground terminal 1000 VDC 1 min 1000 VDC 1 min Insulation resistance Each terminal to ground terminal 20 MV or greater at 500 VDC Rated power supply frequency 50 60 Hz automatic switching Power consumption St