1. Appendix D Stopping ClearSCADA from Running Automatically The ClearSCADA Server runs as a Service in the Windows OS Generally the server is configured to startup at the same time as the machine boots up however it is possible to setup ClearSCADA so that the database only runs when manually started typically through the server icon To put the ClearSCADA Server Service into manual mode 1 Open the Windows Control Panel 2 Select Administrative Tools and then Services 3 Locate ClearSCADA Server in the list Services File Action View Help Fara By Services Local 3 Services Local ClearSCADA Server Name Description Status Startup Type Log On As By Application Layer G Provides s Started Manual Local Service By Application Manage Provides s Manual Local System SBy ASP NET State Ser Provides s Manual Network 5 Sp ati HotKey Poller Started Automatic Local System Description y Automatic Livelpd Manages t Disabled Local System Tie Samida eon CESI N Sip automatic Updates Enables th Started Automatic Local System ByBackground Intellig Transfers f Started Automatic Local System S pBluetoath Service Handles ins Started Automatic Local System Bycisco Systems Inc Started Automatic Local System SByClearSCADA Licens The Clears Started Automatic Local System CADA Server The Schnei Started Manual Local System Stop the service Restart the service By ClipBook Enables Cli
2. Disabled Local System SS COM Event System Supports S Started Manual Local System Ka COM System Appl Manages t Manual Local System Sa Computer Browser Maintains a Started Automatic Local System Ey Crypkey License Started Automatic Local System Extended Standard 7 21 4 Double Click on ClearSCADA Server ClearSCADA Server Properties Local Computer PR General Log On Recovery Dependencies Service name DBSERVER Display name Description The Schneider Electric ClearSCADA database ae server Path to executable C Program Files Schneider Electric ClearSCADA DBServer exe Startup type Manual v Service status Started Stop You can specify the start parameters that apply when you start the service from here 5 Select the drop down arrow from the Startup Type field and select Manual 6 Click the Apply button and then the OK button to close the dialog 7 Close the Services dialog and Administrative Tools dialog 8 The ClearSCADA Server should now not start up automatically the next time the workstation is started 22 Appendix E ClearSCADA Uninstall Procedure Prior to uninstalling ClearSCADA you should make a backup of required parts of the ClearSCADA database 1 You can either a Export what you want to keep from ViewX by right clicking on the appropriate group and selecting Export b Backup the entire database folder The location of the database
3. folder can be found under System Configuration Location in the server configuration dialog 1 Start the Server Configuration application by right clicking on the Server Icon in the system tray and selecting Configuration 2 Browse to the System Configuration gt Location c Note that you should shut down the server before backing up the database in this manner 2 If you have been issued a ClearSCADA soft license file for your computer locate it and save it somewhere safe It will be a lic file To uninstall ClearSCADA 1 Stop the ClearSCADA server and close ViewX 2 Remove any system DSN using the Schneider Electric ClearSCADA Driver Check in Control Panel Administrative Tools Data Sources ODBC on the System DSN tab 3 Un install Schneider Electric ClearSCADA from Windows using Control Panel Add Remove Programs Remove any ClearSCADA version installed 4 Delete the ClearSCADA install and database directories as well as the settings folder Refer to the table below for folder locations Note that it may be difficult to locate the settings folder if you don t have the Show Hidden Files option turned on Open a Windows Explorer dialog and from the top menu select Tools Folder Options Select the View tab and ensure the Show Hidden Files and Folders radio button is checked 23 Operating System XP Server 2003 82 bit Windows 7 Windows Vista
4. m Click on the Licenses button The Client Licensing dialog will appear m Click on the browse button located to the right of the License File field Note If odd characters exist in the License File field delete them as they prevent the file browser from being displayed m Browse to the license file located on the hard drive and click Open m In the Client Licensing dialog click on Apply m Click on the OK button m Close the ClearSCADA Client dialog m Rejstart ViewX Note the above steps are also used to activate the ViewX license on a remote client Upgrading your License Both the hardware and software licenses may be upgraded after they are installed Upgrading the USB key Hardware License m From the Start menu select Programs Schneider Electric ClearSCADA Dongle Field Exchange Utility m Click on Get Locking Code m Send this locking code and the Dongle serial number in a email to SCADACare controlmicrosystems com Once the email is received our customer support group will reply with a new unlocking code Paste this code into the field below the Get Locking Code field in the Field Exchange Utility Upgrading the Software License Email the following information to SCADACare controlmicrosystems com m Machine ID see above m License serial number located on back of CD case 18 Within one business day you will receive a response to your email complete with the required license
5. file and instructions to upgrade your license Appendix C Starting and Stopping ClearSCADA The ClearSCADA Server icon is a separate application and is not part of the Server Service The Server icon may be launched separately from the Server which means that the Server may be running but the icon may not be visible If the ClearSCADA Server is set to start automatically as a service on PC startup the Server icon will appear as normal in the system tray If the icon is not visible you can launch the Server icon by clicking on Windows Start All Programs Schneider Electric ClearSCADA Server icon If the ClearSCADA Server is stopped the Server icon will appear greyed out like this If the ClearSCADA Server is running the Server icon will appear blue like this You can start the server by right clicking on the Server icon and selecting Start Server R E i Start Server Exit TES 4 06 2010 19 Similarly if the server is currently running right click on the icon and select the Shutdown Server option You may be required to log on if security is enabled on your database For the example projects loaded by the Demonstration install enter the username as Eng with no password Status Configuration License Details Archive Volumes Check Integrity Compress Database View DBSnapshot_001 log View DBStartup_001 log a View DB_001 log Shutdown Server TTT 20
6. language support This document is a guide to help new users install ClearSCADA A background in both programmable logic controllers PLC and personal computers PC using Windows is highly recommended If any problems arise during the setup it may be necessary to consult the ClearSCADA User s Manual or call our Technical Support Department for assistance Technical Support The Americas Available Monday to Friday 8 00am 6 30pm Eastern Standard Time Toll free within North America 1 888 226 6876 Direct Worldwide 1 613 591 1943 Email technicalsupport controlmicrosystems com Technical Support Europe Africa Middle East Available Monday to Friday 8 30am 5 30pm Central Europe Standard Time Direct Worldwide 31 71 579 1655 Email euro support controlmicrosystems com Technical Support Asia Pacific Australia Schneider Electric Australia Direct 1300 369 233 Email au helpOschneider electric com Asia Available Monday to Friday 8 00am 6 30pm UTC 05 00 Eastern Time US 8 Canada Direct worldwide 1 613 591 1943 Email technicalsupport controlmicrosystems com 1 Getting Started After inserting the CD the following screen will be displayed ClearSCADA Software for Telemetry Remote SCADA Solutions gt Installation guide gt Install ClearSCADA gt Getting Started gt Release Notes gt Upgrading gt ClearSCADA Website gt Tech Support gt Browse CD gt
7. specification computers depending on the actual configuration NOTE The amount of disk space required is determined by the number of historic and event journal records stored over time This can be calculated from the size of each historic record and event journal record More Information For more information on recommended PC configuration including disk configurations refer to the ClearSCADA online help available on the ClearSCADA install CD 1 Navigate to CD Documentation 2 Open the file ViewX chm this is the ClearSCADA help file 3 Using the tree view on the left hand side navigate to Core Reference gt Server Administration gt Welcome to the Server Administration Guide gt System Server Requirements 4 For information on client requirements navigate to Core Reference gt Client Administration gt Welcome to the ClearSCADA Guide to Client Administration gt Client PC Requirements 5 For further advice please contact Technical Support Application Server Requirement Small stand alone client server with up to 1000 objects Dual core processor 4GB RAM 25GB free disk space Desktop class hardware and operating system Small stand alone client server with up to 10 000 objects and 1 2 remote clients Dual core processor 4GB RAM 50GB free disk space Desktop class hardware and operating system Server with 10 000 objects 5 000 historic points stored for 2 years on line 3 or mo
8. CEULA is a legal agreement between you hereinafter called the Licensee and Control Microsystems Inc a corporation existing pursuant to the laws of Canada herein the Company for the computer software electronic documentation and the media upon which w 1 do not accept the terms in the Licence Agreement T crel 10 3 Enter your user details and click Next 113 Schneider Electric ClearSCADA 2010 R3 Setup Customer Information Please enter your customer information User Name Organisation pe o ooo 4 Select the Full Recommended option ii Schneider Electric ClearSCADA 2010 R3 Setup x Choose Setup Type Choose the setup type that best suits your needs Full Recommended Installs the necessary components and example projects to develop a ClearSCADA database and run it on one workstation Typical Installs the most common components without example projects Connection between server and client must be configured e Custom A Allows individual components to be selected lt Back Next gt Cancel The following setup types are available m Full Recommended this installs both the client and server components for running ClearSCADA on a single machine This install also includes the example projects and is recommended for new users m Typical this installs the most common server and client components and allows the user to select from Server
9. ClearSCADA Software for Telemetry amp Remote SCADA Solutions Schneider ClearSCADA Getting Started Guide 2011 Control Microsystems Inc All rights reserved Printed in Canada Trademarks ClearSCADA is a registered trademark of Control Microsystems Inc All other product names are copyright and registered trademarks or trade names of their respective owners Table of Contents Welcome to ClearSCADA 0 o 1 Getting Started iia car ae ri ee ha te wage ea 2 System Requirements o e eee eee 3 ClearSCADA Demonstration Version 9 Installing ClearSCADA o 10 Next Steps ks aio rr ara GOP Goan ee I S 15 Appendix A Troubleshoot ClearSCADA Installation 16 Appendix B Adding a licence to your system 16 Appendix C Starting and Stopping ClearSCADA 19 Appendix D Stopping ClearSCADA from Running Automatically 21 Appendix E ClearSCADA Uninstall Procedure 23 Welcome to ClearSCADA Welcome to ClearSCADA our SCADA system software ClearSCADA is a powerful client server SCADA system with m Online configuration including mimics graphic display trends communications objects points schedules reports etc m Built in fully featured historian OPC and ODBC support at both the client and server m Web server and IT integration features m Query based lists of database items m IEC 6 1131 programming
10. Exit aura A number of different options are available a Installation Guide displays this document m Install ClearSCADA starts the ClearSCADA installation program m Getting Started provides short tutorial videos showing you how to get started with ClearSCADA and information on using DNP3 and SCADAPack Modbus protocols Release Notes what s new in this version of ClearSCADA Upgrading information on upgrading existing versions of ClearSCADA m Exit closes the ClearSCADA setup utility System Requirements Operating Systems ClearSCADA can be installed on 32 bit or 64 bit computers Systems running on server hardware need to use server operating systems such as Windows Server 2008 or Windows Server 2003 Server operating systems are designed for servicing entire systems rather than individual computers or small networks and are therefore better suited for larger ClearSCADA systems with more than two clients Systems running on desktop hardware need to run desktop operating systems that are designed for user interaction on the computer on which they are installed ClearSCADA supports the following operating systems Windows 7 Professional and Ultimate editions m Windows Vista Business and Ultimate editions m Windows XP Professional Edition NOTE Windows XP Windows Vista and Windows 7 should not be used for servers with more than two clients as the TCP IP security measures in these operating syst
11. Program Files systems ClearSCADA DatalControlMicrosys ControlMicrosystems tems ClearSCADA ClearSCADA ClearSCADA 2010 C Program Files x86 C Documents and Set C Documents and R2 X and R3 X SchneiderElectric tings All Users Applica _ Settings lt User gt Local ClearSCADA tion Data SchneiderElec Settings Application C Program Files tric ClearSCADA Data SchneiderElectric SchneiderElectric ClearSCADA ClearSCADA ClearSCADA 2009 C Program Files x86 _ C ProgramData CAUsers lt User gt App R2 X ControlMicrosystems ControlMicrosystems DatallLocal ClearSCADA 2010 ClearSCADA ClearSCADA ControlMicrosystems R1 X C Program Files ClearSCADA ControlMicrosystems ClearSCADA ClearSCADA 2010 C Program Files x86 _ C ProgramData CAUsers lt User gt App R2 X and R3 X SchneiderElectric SchneiderElectric Data Local ClearSCADA ClearSCADA SchneiderElectric C Program Files ClearSCADA S chneiderElectricl ClearSCADA 24 48 Steacie Drive Kanata Ontario Canada K2K 2A9 Telephone 613 591 1943 Facsimile 613 591 1022 Technical Support 888 226 6876 888 2CONTROL
12. Select the Security tab 4 Select the Trusted Sites icon 5 Select the Sites button to display the Trusted Sites dialog box The URL of the WebX connection to the server should be shown in the Add this website to the zone field 6 Add the URL to the list of Trusted Sites e f you use secure URLs https select the Add button The connection to the ClearSCADA server is now added to your list of Trusted Sites and will be unaffected by the XSS filter issue e f you use non secure URLs http you should clear the Require server verification https for all sites in this zone check box This allows you to add non secure sites to the Trusted Zone Then select the Add button to add the connection to the ClearSCADA server to your list of Trusted Sites 7 On the Security tab select the Trusted Sites icon and then select the Custom Level button This displays the Security Settings dialog box 8 Scroll down to the Enable XSS Filter setting 9 Select Disable for the Enable XSS Filter setting 10 Select the OK button 11 On the Internet Options dialog box select the Close button 12 Repeat this process on each Webx client Alternatively you could access the Custom Level settings for the Internet zone and disable the Enable XSS Filter setting However this would apply to all connections over the Internet not just those to a ClearSCADA server For this reason we recommend that you use the Trusted Sites work around as des
13. This relates to a problem with IE9 s Cross Site Scripting XSS filter and only occurs if you use WebX to access a ClearSCADA server m Over the Internet m Over an Intranet connection where m anode name is used in the URL and m the security settings for the Local Intranet zone have been modified so that the XSS filter is enabled m By using an IP address to reference the ClearSCADA server rather than a node name Typically the hanging occurs when displaying Query lists including Events Lists that have complex filters For example if you use WebX to display an Events List that has multiple WHERE AND OR filters specified in its query IE9 may hang A common situation in which this can occur is when the Display Events action is selected for an object on a Mimic There is a simple and effective work around that will allow you to display filtered query lists in WebX You need to add the connection to the server to the list of Trusted Sites and then disable the XSS Filter setting To add a WebX to ClearSCADA server connection to your Trusted Sites 1 Using a WebxX client log on to the ClearSCADA server you want to access You will need to use a Username and Password that is valid for a ViewX User account and that User account has to have the appropriate permissions to access the server 2 Once you have logged on to the server select Tools gt Internet Options to display the IE9 Internet Options dialog box 3
14. Windows Server 2008 32 bit Server 2003 64 bit Windows 7 Windows Vista Windows Server 2008 64 bit Windows Server 2008 R2 64 bit ClearSCADA Install Database Global Version Directory Location Settings ClearSCADA 2009 C Program Files C Documents and Set C Documents and R2 X ControlMicrosystems tingsWAll Users Applica Settingsi lt User gt Local ClearSCADA 2010 ClearSCADA tion Data ControlMicro SettingsApplication R1 X systems ClearSCADA DatalControlMicrosys lems ClearSCADA ClearSCADA 2010 C Program Files C Documents and Set C Documents and R2 X and R3 X SchneiderElectric tings All UsersApplica Settingsi lt User gt Local ClearSCADA tion Data SchneiderElec Settings Application tric ClearSCADA Data SchneiderElectric ClearSCADA ClearSCADA 2009 C Program Files C ProgramData C Users lt User gt App R2 X ControlMicrosystems ControlMicrosystems DatallLocal ClearSCADA 2010 ClearSCADA ClearSCADA ControlMicrosystems R1 X ClearSCADA ClearSCADA 2010 C Program Files C ProgramData C Users lt User gt App R2 X and R3 X SchneiderElectric SchneiderElectric Data Local ClearSCADA ClearSCADA SchneiderElectric ClearSCADA ClearSCADA 2009 C Program Files x86 C Documents and Set C Documents and R2 X ControlMicrosystems tingsWAll Users Applica Settingsi lt User gt Local ClearSCADA 2010 ClearSCADA tion Data ControlMicro SettingsApplication R1 X C
15. You will not be able to configure 2 or more ClearSCADA Servers in a redundant configuration in Demonstration Mode If you wish to evaluate ClearSCADA in a redundant configuration then we suggest that you discuss this with your ClearSCADA distributor See Appendix B for details on requesting and installing a ClearSCADA license Installing ClearSCADA Before beginning the installation please ensure the following m You are logged onto your computer with administrator privileges m All firewalls are turned off i e Norton ZoneAlarm BlackICE etc m All other applications are closed 1 Select the Install ClearSCADA option from the ClearSCADA Setup window and then Next to begin the installation NOTE The ClearSCADA installer will install any prerequisites before beginning the main installer Schneider Electric ClearSCADA 2010 R3 Setup E x Welcome to the Schneider Electric ClearSCADA 2010 R3 Setup Wizard The Setup Wizard will install Schneider Electric ClearSCADA 2010 R3 on your computer Click Next to continue or Cancel to exit the Setup Wizard 2 Review the Licence Agreement and select I accept the terms in the Licence Agreement Click Next fe Schneider Electric ClearSCADA 2010 R3 Licence Agreement t xj End User Licence Agreement Please read the following licence agreement carefully END USER LICENSE AGREEMENT FOR ClearSCADA IMPORTANT READ CAREFULLY This End User License Agreement
16. and clients clients only or data access components Example projects are not installed This is recommended for more advanced users 11 m Custom this allows the user to define the required installation components This is recommended for users familiar with ClearSCADA operation 5 ClearSCADA will prompt you to create a username and password for the Super User account Enter a username and password The Super User has security privileges above and beyond all other Users on the system Click Next ig Schneider Electric ClearSCADA 2010 R3 Setup Super User Account Please enter the username and password for the super user account User Name Password oo Confirm Password JT Disable super user account omn 6 Click Install to begin the installation fe Schneider Electric ClearSCADA 2010 R3 Setup 3 x Ready to Install The Setup Wizard is ready to begin the Full installation Click Install to begin the installation IF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard 12 7 Select Finish to allow the Demo Projects launcher to begin i Schneider Electric ClearSCADA 2010 R3 Setup E x Completing the Schneider Electric ClearSCADA 2010 R3 Setup Wizard Click the Finish button to exit the Setup Wizard cora 8 The ClearSCADA Server will start the ViewX client will start and the example databa
17. cribed above NOTE Crystal Reports XI Release 2 is not supported by the vendor on Windows Server 2008 or Windows Server 2008 R2 For users with installed Server 2008 or Server 2008 R2 systems it is recommended that the Crystal development application is installed on a Server that is NOT running Windows Server 2008 or Windows Server 2008 R2 64 bit Operating Systems ClearSCADA can be installed on computers using the following operating systems Server Hardware m Windows Server 2008 Release 2 Standard and Enterprise editions initial release and Service Pack 1 m Windows Server 2008 Standard and Enterprise editions initial release and Service Pack 2 m Windows Server 2003 Release 2 Standard and Enterprise editions Service Pack 2 m Windows Server 2003 Standard and Enterprise editions Service Pack 2 Recommended PC Configurations The following table lists the recommended PC configurations for a variety of client and server scenarios In the table the term object refers to a database item whereas point refers to a specific type of database item that stores I O a database point Historic points are database points that have the Historic feature enabled NOTE The typical point to object ratio is around 1 2 so for a system with 50 000 points this equates to around 100 000 objects However ratios vary per system and this should only be regarded as an estimate Some ratios may require lower or higher
18. e ViewX shortcut may be used to launch the ViewX client for any subsequent ClearSCADA evaluation sessions view 14 The ClearSCADA Server shortcut is used to display the status of the ClearSCADA server in the system tray Next Steps A number of tools are available to help new users get started with ClearSCADA 1 Videos from the ClearSCADA Setup utility select Getting Started From this page three videos are available a Introduction to ClearSCADA this provides a general introduction to the concepts used in ClearSCADA This video will take you through creating points mimics alarms trends and object menus b Introduction to DNP3 this video will show you how to create database objects to communicate with a DNP3 device c Introduction to SCADAPack Modbus this video will show you how to create database objects to communicate with a SCADAPack RTU 2 ClearSCADA Tutorial the online help contains a Tutorial for users to step through their first configuration This will explore concepts such as using ViewX using the WebX client configuration as well as templates and instances 3 Presentation as part of the installed Example Projects a presentation is available that describes the key features and benefits of ClearSCADA and how ClearSCADA differs from other products This provides a great overview of the key concepts that will be useful as you start to design and build ClearSCADA systems 4 Exam
19. ems can cause significant delays 32 bit Operating Systems ClearSCADA can be installed on computers using the following operating systems Server Hardware m Windows Server 2008 Standard and Enterprise editions initial release and Service Pack 2 m Windows Server 2003 Release 2 Standard and Enterprise editions Service Pack 2 m Windows Server 2003 Standard and Enterprise editions Service Pack 2 Desktop Hardware m Windows 7 Professional and Ultimate editions initial release and Service Pack 1 m Windows Vista Business and Ultimate editions Service Pack 1 and Service Pack 2 m Windows XP Professional Edition Service Pack 3 ClearSCADA also requires Internet Explorer 6 7 8 or 9 Other browsers are not supported Support for Internet Explorer 9 There is a known issue with Internet Explorer 9 s Cross Site Scripting XSS Filter that can cause Internet Explorer 9 to hang This only applies when m Using IE9 to connect to ClearSCADA over the Internet m Using IP addresses in the URL for the ClearSCADA server m The default security settings for the Local Intranet zone have been modified Please read the section below for more information about this issue and instructions on how to prevent or correct this issue Internet Explorer 9 XSS Filter Issue Hanging A bug in Internet Explorer 9 may cause hanging IE9 will freeze and be unable to display the requested information
20. iguration log files etc A separate 4TB redundant array of disks for historic data Server class hardware and 64 bit operating system Server with 450 000 objects 250 000 historic points stored for 2 years on line multiple clients 2 x Quad core server class processor 48GB RAM 100GB free space on a redundant array of disks for configuration log files etc A separate 8TB redundant array of disks for historic data Server class hardware and 64 bit operating system ClearSCADA Demonstration Version When installing ClearSCADA for the first time it is recommended that you install the Full Recommended Version The Full Recommended Version installs a subset of common drivers and core functionality of the ClearSCADA software and ViewX client as well as the following m Overview Tutorial m Sample Projects m Symbol Library The Demonstration version of ClearSCADA does contain some limitations as compared to the fully licensed version of ClearSCADA These include m The ClearSCADA Server will run for 2 hours at a time then automatically shut down m The ClearSCADA Server is limited to 1000 points Once you exceed this number you will be unable to create additional points in the database m The ClearSCADA Server will allow you to connect 2 ViewX clients 1 OPC client 1 Data access client and 2 Web clients If you purchase a license for ClearSCADA it will define the number of clients that can attach to your server m
21. ion be made to the PC i e adding a new network card that changes the PC s machine ID the software license may become invalid and a new license will need to be installed A software license cannot be transferred from one PC to another It is PC specific To obtain a software license 1 Start the ClearSCADA Server and right click on the ClearSCADA Server icon in the system tray lower right corner of screen Select License Details from the menu Note the Machine ID number To avoid transcription errors we suggest that you copy and paste this number into an email see step 2 2 Email the following information to SCADACare controlmicrosystems com m Machine ID this should be copied and pasted from Step 1 m License serial number located on back of CD case Within one business day you will receive a response to your email complete with the required license file and instructions to activate your license To activate your software license for the server m Save the attached license file to your computer remember the location where you place the file m Right click on the server icon in the system tray m Select License Details m Browse to the license file m Select file and click Open 17 To activate your license for the local embedded client m From the Start menu select Programs Schneider Electric ClearSCADA Configure ClearSCADA Connections The ClearSCADA Client dialog will appear
22. ple Projects the example projects installed as a part of the Demonstration Installation show you how to configure a real database considering concepts such as database structure security as well as templates and instances Further information is available on our Resource Centre and you can obtain support from other ClearSCADA users on the SCADAForum Links to both sites are available on our website 15 Appendix A Troubleshoot ClearSCADA Installation The installation may take a few minutes and is completed automatically unless m There is insufficient disk space If you have this problem you need to make more disk space available by deleting files or installing additional disk space m The source files cannot be found If this occurs you need to ensure that ClearSCADA can access the installation files on the ClearSCADA CD ROM m There has been an error in the installation procedure If this occurs you should contact Technical Support m Your Microsoft Windows user account does not have the administrator level privileges Refer to your Microsoft Windows documentation for more information m You have a software firewall running during the installation that interferes with the installation While the installer should work with firewalls if you have problems try running the installer with the firewall disabled Appendix B Adding a licence to your system Once installed when the ClearSCADA Server is started it
23. re clients Quad core server class processor 8GB RAM 25GB free space on a redundant array of disks for configuration log files etc A separate redundant array of disks for historic data Server class hardware and 64 bit operating system Server with 50 000 objects 25 000 historic points stored for 2 years on line multiple clients Quad core server class processor 8GB RAM 25GB free space on a redundant array of disks for configuration log files etc A separate 500GB redundant array of disks for historic data Server class hardware and 64 bit operating system Server with 100 000 objects 75 000 historic points stored for 2 years on line multiple clients Quad core server class processor 16GB RAM 50GB free space on a redundant array of disks for configuration log files etc A separate 1TB redundant array of disks for historic data Server class hardware and 64 bit operating system Server with 175 000 objects 100 000 historic points stored for 2 years on line multiple clients Quad core server class processor 16GB RAM 50GB free space on a redundant array of disks for configuration log files etc A separate 2TB redundant array of disks for historic data Server class hardware and 64 bit operating system Server with 250 000 objects 150 000 historic points stored for 2 years on line multiple clients 2 x Quad core server class processor 32GB RAM 100GB free space on a redundant array of disks for conf
24. se with sample programs and overview tutorial will be imported This may take a few minutes please be patient ClearSCADA Demo Launcher N Project Example Projects sde v Install Starting server OK Creating dient system OK Starting database OK Importing demo group You should now be running the ClearsCADA Server This is indicated by the presence of the blue icon in the system tray lower right corner of the screen If this icon is not present or is another color the ClearSCADA Server is not running properly If the server is not running properly please refer to Appendix A Troubleshoot ClearSCADA Installation at the back of this document 13 You should also be running the ViewX client as indicated in the screen shot below Please note that the demo projects in the Demonstration Version will trigger system alarms resulting in an audible alarm bell To silence the alarm right click on the large red 10 button this number may be different on your screen in the lower left corner of the screen and select Disable Bell na Mo DD es0eneee DESTE i naar eet B ua mest ClearSCADA Enterprise software for remote SCADA gt Presentation gt Projects Schneider q o w Soru tmang cer open aee comer 0 Three new shortcuts have been added to your desktop The ClearSCADA Service Manager is used for manually starting and stopping the ClearSCADA Server Th
25. will run in demo mode for a period of 2 hours Once the 2 hour period has expired the Server will shut down Changes to the database and historic logged data will not be lost when this happens A user simply needs to restart the server to re establish a connection to the database Licensing ClearSCADA can be performed in one of the following two ways m Hardware License USB dongle m Software License lic file Hardware License The USB key hardware license has the advantage of not being PC specific The key can be used on any PC running ClearSCADA which means a user may in effect take their license with them The downside to the USB key hardware license is that once removed ClearSCADA reverts back to demo mode which means the USB key must be inserted at all times in order for the license to be seen as valid by the ClearSCADA Server 16 Hardware licenses are typically shipped with the ClearSCADA CD at the time of order To obtain a USB key hardware license email your inquiry to SCADACare controlmicrosystems com Within one business day you will receive a response to your email complete with instructions of delivery Software License The software license has the advantage of being permanently installed on the PC thereby ensuring that ClearSCADA will always be licensed on that machine The downside to the software license is that it is hard coded to the PC s machine ID Should a hardware configurat