Home
1311 and 1312
Contents
1. A Discharged battery notification a When the battery of a configured transmitter is almost discharged the 4 red LED will flash several times every three seconds The number of y times the red LED flashes indicates the zone in which the transmitter is i A configured A 1 pulse is the STANDARD zone I j amp 2 pulses is the FALL DET zone 3 pulse is the 24hZONE zone a A The transmitter will continue to operate but replace the battery as soon tw as possible When the receiver is switched off an alarm tone will also sound to indicate that a discharged battery notification is stored in memory On the rear is a sticker on which a combination of letters and numbers can be marked Mark the same combination on a configured device such as an Optiscan sensor to indicate that these are configured to work together Receiver 230W 50HF A B C D E F G H 1 1 2 3 4 5 6 7 8 9 10 1311050137 a Neat Generation CE uN Although this 1311 receiver has an earthed plug it don t require an earthed wall socket this receiver is double insulated therefore the earth pin is not connected
2. 1311 and 1312 User manual Receiver and Plug amp Play Receiver These receivers are used in combination with various wireless equipment such as Optiscan sensors the Optiseat chair alarm door window switches neck chain pendant transmitters with and without man down function etc The manner in which these receivers function depends on their programming Because it is not possible to provide a separate user manual for each configuration this manual is based upon the standard most common situation Connection of the receiver to a nurse call system Place the receiver in the electrical socket near the connection for the nurse call system Because the Plug amp Play receiver art no 1312 obtains power via the link cable this step does not apply to this model Use the provided cable to connect the receiver to the nurse call system After several seconds a short beep will be heard l The receiver is now ready for use Use of the receiver without a nurse call system When no nurse call system is present the receiver will be programmed to produce an acoustic signal Place it in an electrical socket where the caregiver can hear the alarm This must however be within range of the transmitter that is configured to this receiver on average 40 metres Always test the range Switching on the receiver By default pressing the button on the receiver will switch it on and cause a green lamp in the button to lig
3. ht It may be however that due to a change to the receiver s programming the button must be held for several seconds before it will switch on or off If may also be if so configured that the green lamp goes out after two seconds Upon alarm During an alarm the red lamp in the button will light By default this will also automatically go out Depending on the programming it may be that it remains lit until confirmation is received from the caregiver In this case the alarm is confirmed by pressing the button This option will often be used if no nurse call system is present the receiver will continue to beep until it is reset Alarm zones In total 16 different transmitters can be configured to 1 receiver This receiver works with zone programming This means that certain devices are configured to the appropriate zone There are a total of 3 types of zones Of these two produce alarms even when the receiver is off These are used for devices such as the neck chain pendant transmitter with or without man down function the Optiseat chair alarm door switches and smoke detectors The Optiscan sensor is configured to the zone that is controlled via the on off function In this manner in a situation where both an Optiscan sensor and a neck chain pendant transmitter are configured to a single receiver it is possible to switch the Optiscan off via the receiver while the alarms from the neck chain pendant transmitter are still produced
Download Pdf Manuals
Related Search
Related Contents
Rommelsbacher TA 1200 tea maker 取扱説明書 詳細操作編 Home Decorators Collection 1598300310 Use and Care Manual OLIMEXINO-5510 USER`S MANUAL USB2512A USB 2.0 Hi-Speed 2-Port Hub Controller Data Sheet Hampton Bay 15039 Installation Guide 仕様書(PDF:114KB) GG F -IT Copyright © All rights reserved.
Failed to retrieve file