Home

SIMADYN D Digital Control System Memory Board MS41

image

Contents

1. SIMADYN D User Manual Digital Control System Memory Board MS41 Edition 04 97 DK No 252341 User Manual Memory Board MS41 Memory Board MS4 MS41 03 91 Memory Board MS4 MS41 05 95 Memory Board MS41 04 97 Copying of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utility model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are thankful for any recommendations or suggestions Contents Contents Warning TOMAN ia a o ld ald cd ie dt 1 t Ordering NO MN O ii tad 3 2 FUNCION A eScAptiON isi diia da ns 3 IAB AAN tarea lo locas 3 4 Application Into MON ti dead eno 4 5 Gonnector assi Mii debida 4 6 Fechnicaldata terea iria iia idad 5 7 STRUC L mask in the master prOglaM ooooccccnnnnccccnnonaccnnnnnn anncnnnnncc nn nan nn cnn nan ncn nn arrancan 5 Si Ata MS e e a ed bcc 5 8 1 Dimension drawing and table of the CONNectoFS ooooooccccnnoccccconacnncnnon cnnnnnnnnnancnanannnan ns 5 9 ESDAASTUICUOANAS o a a od a e e
2. apacity in kbyte EPROM 512 EEPROM 2 Starting address hex EPROM 80000 EEPROM 7C000 Access time when writing MS41 EPROM 70 ns EEPROM 300 ns Data format EPROM 16 bit EEPROM 8 bit Write cycle EEPROM max 2 ms Siemens AG Dk No 252341 Edition 04 97 3 SIMADYN D Hardware User Manual Application information 4 Application information The modules may not be programmed when they have been warmed up e g after they have been removed from the erase device The MS41 board uses components which can be destroyed by electrostatic discharge ESD The following protective measures must be observed when handling the boards Only touch the board if a grounded object is simultaneously touched e g cabinet ground grounding panel Only transport the board in the original conductive packing Only set the board down on conductive surfaces It must not come into contact with highly insulating materials e g plastic articles of clothing manufactured from man made fibers The MS41 board could be destroyed when programming in an office environment carpets It is necessary to set up a special programming station with grounded desktop and grounding band for the operating personnel Labels are provided with every memory board These labels must be attached over the EPROMs after the board has been programmed to protect it from light 5 Connector assignment The three row 48 pin plug connector has the following assignmen
3. dd 6 Siemens AG Dk No 252341 Edition 04 97 SIMADYN D Hardware User Manual Warning information Edition 04 97 Siemens AG Dk No 252341 SIMADYN D Hardware User Manual Warning information NOTE The information in this Manual does not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes please contact your local Siemens office Further the contents of this Manual shall not become a part of or modify any prior or existing agreement committment or relationship The sales contract contains the entire obligation of Siemens The warranty contained in the contract between the parties is the sole warranty of Siemens Any statements contained herein do not create new warranties nor modify the existing warranty Warning information WARNING Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to this can result in severe bodily injury and material damage Only appropriately qualified personnel may work on this equipment or in its vicinity This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual The successful and safe operation of this equi
4. pment is dependent on prope handling installation operation and maintenance Siemens AG Dk No 252341 Edition 04 97 1 SIMADYN D Hardware User Manual Warning information Definitions QUALIFIED PERSONNEL For the purpose of this User Manual and product labels a Qualified person is someone who is familiar with the installation mounting start up and operation of the equipment and the hazards involved He or she must have the following qualifications 1 Trained and authorized to energize de energize clear ground and tag circuits and equipment in accordance with established safety procedures 2 Trained in the proper care and use of protective equipment in accordance with established safety procedures 3 Trained in rendering first aid DANGER For the purpose of this User Manual and product labels Danger indicates death severe personal injury and or substantial property damage will result if proper precautions are not taken WARNING For the purpose of this User Manual and product labels Warning indicates death severe personal injury or property damage can result if proper precautions are not taken CAUTION For the purpose of this User Manual and product labels Caution indicates that minor personal injury or material damage can result if proper precautions are not taken NOTE For the purpose of this User Manual Note indicates information about the product or the respective part of the U
5. ser Manual which is essential to highlight CAUTION This board contains components which can be destroyed by electrostati discharge Prior to touching any electronics board your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact WARNING Hazardous voltages are present in this electrical equipment during operation Non observance of the safety instructions can result in severe personal injury or property damage It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed 2 Edition 04 97 Siemens AG Dk No 252341 SIMADYN D Hardware User Manual Ordering information 1 Ordering information 6DD 1610 OAG1 MS41 memory board A SIMADYN D Parallel Programmer is required to program the boards 2 Function description The MS41 memory board is a small PC board with one 28 pin and four 32 pin slots The EPROMs contain the machine code for the operating system and the configured user program Changing operating parameters for example controller gains are stored in the EEPROM The MS41 memory board is inserted in the processor board through a cut out in the front panel 3 Board design Small PC circuit board with a 48 pin plug connector CMOS EPROMs can be used for operation with self ventilation Memory c
6. t eee oe a a Fs Tono Vpp OE P5 6 EPROM 5V power supply voltage 6V or 6 25V when programming P5 EEPROM power supply voltage GND Ground Axx Address lines 0 to 16 Dxx Data lines 0 to 15 CSx Chip select 1 to 4 for the EPROM Chip select 5 for the EEPROM OEx Output enable 1 and 2 4 Edition 04 97 Siemens AG Dk No 252341 SIMADYN D Hardware User Manual Technical data 6 Technical data Insulation group A acc to VDE 0110 Para 13 Group 2 at 5V DC Ambient temperature 0 to 55 degrees C Storage temperature 40 to 70 degrees C Humidity rating F acc to DIN 40040 Dimensions 101 4 53 3 mm Weight in kg 0 08 Current drain P5 Typ inmA 150 Typ at 16MHz 250 max 7 STRUC L mask in the master program MS41 Memory board 512k 8 Attachments 8 1 Dimension drawing and table of the connectors Dimension drawing and table of the connectors 3SE 465 610 9006 01 MB Siemens AG Dk No 252341 Edition 04 97 5 SIMADYN D Hardware User Manual ESD instructions 9 ESD instructions Components which can be destroyed by electrostatic discharge ESD Generally electronic boards should only be touched when absolutely necessary The human body must be electrically discharged before touching an electronics board This can be simply done by touching a conductive grounded object directly beforehand e g bare metal cubicle components socket outlet protective conductor contact Boards must not come into contac
7. t with highly insulating materials e g plastic foils insulated desktops articles of clothing manufactured from man made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive packing material e g conductive foam rubber or household aluminum foil The necessary ESD protective measures are clearly shown in the following diagram a Conductive floor surface d ESD overall b ESD table e ESD chain c ESD shoes f Cabinet ground connection 6 Edition 04 97 Siemens AG Dk No 252341 SIMADYN D Hardware User Manual ESD instructions Siemens AG Dk No 252341 Edition 04 97 7 SIMADYN D Hardware User Manual ESD instructions Drives and Standard Products Motors and Drive Systems Group Postfach 3269 D 91050 Erlangen System Based Drive Technology Edition 04 97 Siemens AG Dk No 252341 SIMADYN D Hardware User Manual ESD instructions Siemens AG Dk No 252341 Edition 04 97 9 SIMADYN D Hardware User Manual