Home

AT100

image

Contents

1. Average temperature since the previous message 1 hour continuous Average Max Min 24 hours continuous Average Max Min Serial number of the unit MBUS Unique Identification Number Battery status Electronic seal Message formats The messages below are described in plain text Fields marked with green will be encrypted if encryption is activated For detailed information see EN 13757 4 2 3 0x5193 Manufacturer TLS i Ox1B Product type Room sensor Ox7A Cl field Access number increased by each regular 10 11 12 13 Oxnn transmission 0x00 Normal Status 0x04 Low battery level 0x03 Seal open 0x0000 Not Encrypted Encryption settings 14 15 16 Ox Encrypted 17 18 Ox2f2f Idle filler encryption verification Ox02 DIF Current temperature 0x65 VIF signed 16bit 2 decimals Oxnnnn Current temperature with 2 decimals when error set to 0 Ex 2310 23 10 C y 9 N 0 21 22 N SN 0x82 Oxb2 DIF 24 hours continuous average value store value 1 0x82 Reliable Oxb2 Non reliable 00 0x01 DIFE WO 0x65 VIF signed 16bit 2 decimals User Manual AT100 30 31 Oxnnnn 24 hours continuous average temperature 2 decimals when error set to 0 Ex 2310 23 10 C 34 35 Oxnnnn 1 hour continuous Min temperature 2 decimals when error set to 0 Ex 2310 23 10 C 29 Oxnnnn 1 hour continuous Max temperature 2 de
2. e Roughly structured surfaces e Structured wallpaper The unit is activated when it is first opened To verify that the unit is working correctly the LED will light up with a red light showing for ten seconds every time the unit is opened Location For correct recording of the temperature the AT100 should be placed on a spot with even temperature Avoid mounting in the kitchen outside the bathroom and areas exposed to direct sunlight The unit should be placed on an inner wall 1 meter horizontally from the nearest radiator and at a height of at least 150 cm H US Rev l O I 1234567890 Figur 1 taking apart the unit Figur 2 identification and serial number of the unit TUS i Mounting with double sided adhesive tape Note The back of the unit is coated with very strong adhesive tape and removal of the unit will cause damage to the wall surface Please note that the unit can be exchanged without causing damage The product has industrial strength adhesive tape attached to the back To mount the unit 1 Determine the location of the unit 2 Clean the surface on which the unit will be placed 3 Remove the protective film on the back of the unit Press the unit against the wall for about 10 seconds 4 Carefully loosen the lid and pull it straight out to remove it see fig 1 Check that the LED shows a red light for 10 seconds 5 Note down the serial number of the unit and press back the unit into the holder p
3. aying attention to the TOP marking on the circuit board Mounting with screw For mounting the unit on surfaces not suitable for adhesive tape screws can be used instead 1 Determine the location for the unit and centre drill a hole using the template 2 Carefully loosen the lid and pull it straight out to remove it see fig 1 The LED light should light up for 10 seconds 3 On the bottom of the unit there are weaker points where the screws can be used 4 Note down the serial number of the unit and press back the unit into the holder paying attention to the TOP marking on the circuit board Encryption codes and password For security reasons all the encrypted AT100 are delivered with different encryption codes The codes are delivered digitally in a csv file for import to the reading system i Usage Mobile phones with NFC Near Field Communication can be used to gain information about the current temperature by tagging or touching the unit with the back of the mobile phone Mobile phones with NFC function 1 Activate the NFC through the phone settings 2 Drag the back of the phone slowly towards the unit As the antennas align a link will open on the phone showing the temperature reading Communication The unit regularly sends wireless messages with current temperature in a settable interval the messages are in conformity with the Wireless M Bus standard EN 13757 4 in T1 Mode Each message includes
4. cimals when error set to 0 Ex 2310 23 10 C e OE 1 42 43 Oxnnnn 24 hours continuous Min temperature 2 decimals when error set to 0 Ex 2310 23 10 C 1 24 hours Max temperature 2 decimals when error set to 0 Ex 2310 23 10 C i a i cid ii 50 Oxnn Number of seal breakings accumulated at each opening mo User Manual AT100 nd VIF 16bit signed integer Manufacturer specific Technical specifications 0 55 C 10 55 C Temperature accuracy 18 24 C Safety AT100 must only be installed by competent personnel and all safety instructions must be followed during installation and use Documentation regarding the installation and use of the product shall be forwarded to parties involved The battery must not be recharged and may only be replaced by qualified service personnel approved by TLS Energimatning Installation or use may not start until the instructions are read The circuit board is sensitive to static electricity hence during the installation the circuit board must not be touched without the use of ESD bracelets or similar The product markings may not be removed amended or in any other way made unidentifiable 10
5. i TS mnt AT100 Wireless temperature sensor for indoor use User manual i All the information in this manual is applicable at the time of publication and may be subject to changes without notice We recommend that prior to the installation you make sure that you have the most recent edition The document may contain errors TLS Energimatning is not responsible for damages obligations or losses caused by the use of this product This document may not be copied in its entirety or in part Contact TLS Energimatning AB Sankt Eriksgatan 117A 11343 Stockholm Sweden info tls se www tls se www tls se Recycling The packaging is recyclable The product except for the battery follows the WEEE directive for recycling When disposing of your product follow the local regulations on recycling The product and or the battery must never be thrown away or subjected to fire but taken care of in accordance with your local regulations regarding chemical waste i Innehallsforteckning MVS CANA CLOUD E a E E EAE EE A E EAE E ETE 4 UC MUU respecte see actos crnce Se ves acicaien tsa etwas oem ceneeiieenmaeeuesdenateotaebeaieen esouenaecanessauseuisesmeuasiaescesesreseneencunseseadeeseseucenes 4 Mounting with double sided adhesive tape ss ssssssssssuusnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 M n np with SCV W sssaaa RaO aE cect ese EEEE E EErEE 5 Encryption codes and
6. password s ssssnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnan nnnnnnnnn nanana 5 Oe e e E E PA A O E A E A A E 6 Mobile phones with NFC funktion ssssusenunnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nn 6 CGT CAOT sorsas aara Na EA Ea a EEA NAANA EANNAN NANNAN ENAN ANEA 6 M ssage formatS ssssiisossisnisnsaaiaan ian n ties vaisausteteespensdeandaneauesiacsbeatinesssanniacinnanloninniasmunlennnneinaeeees 6 Tecnnical specin ONS a E E eee cacaa ten scnsu neue sctelaceresceemenvonsueceeceaseseces 9 SATOI a E tia dees ete E ves taeseadenc anueatusueuneiane 10 Introduction AT100 is a wireless sensor for air temperature for indoor use The sensor reads and transmits regularly the temperature to a wireless MBUS master that stores the readings The unit also contains an electronic seal which indicates if someone has been manipulating the unit Order and purchase To facilitate the installation we recommend that you order the units with or without encryption activated to avoid configuration at the point of installation AT100 E YES i TUS Installation The unit can be mounted using either double sided adhesive tape or a screw The double sided tape is recommended on surfaces such as e Painted walls and ceilings e Painted woodwork e Wallpaper without structure The double sided tape is not recommended for surfaces such as

Download Pdf Manuals

image

Related Search

AT100 at1000hs-ptt-qd-g at1000hs-g at1000 hach at100tg at1000 maya at100tt at1000s at100 antibody at100e cartridge at1000 tube tester

Related Contents

LEDD-60023MN-LD9  SA-WZ8 - Sony Asia Pacific  Fluke 1522 User's Manual  Ordinateur mobile  AgfaPhoto sensor 830s Manual de usuario  UVR61-3    SX-LN131 MOUNTING - 株式会社モデュレックス|ModuleX Inc.  集合形漏電検出装置 取 扱 説 明 書  Page 1 Page 2 Page 3 Page 4 面強圧性能 ー 耐久性能に優れた高  

Copyright © All rights reserved.
Failed to retrieve file