ICP DAS WISE User Manual_v1.26en_790x

image

Contents

1. Subject Content Note The length of the message cannot exceed 160 characters Figure 5 12 Email setting page Follow the following steps 1 Specify the numbers of email messages you want to set up from the dropdown list of the E mail Amount field ll Specify the email group number from the dropdown list of the Index field ii Enter the IP or the domain name of the SMTP server in the SMTP Server field iv If SMTP server requires account and password validation please select the Authentication Checkbox and continue steps v vi to login into the SMTP server If SMTP server don t need account and password validation uncheck the Authentication Checkbox and skip http wise icpdas com 29 ICP DAS WISE User Manual V1 Vil Vill 1X xi xil steps v vi go directly to step vii Enter the SMTP server login ID in the Login ID field Enter the SMTP server password in the Password field Enter the sender s name in the Sender Name field Enter the sender s email address in the Sender Email Address field Enter the receiver s email address in the 1 5 Receiver Email address field Please note you can input up to 5 receivers at least one email address has to be entered Please enter the email address in sequence to avoid possible error Enter the em
2. oooccccccccnnnonoccnnnnnnnnnononinononos 63 Proute E C Eu NEEN 64 Figure 10 1 The LED display shows network information and channel values 65 http wise icpdas com 5 ICP DAS WISE User Manual Figure 11 1 Figure 11 3 Figure 11 7 Figure 11 8 Figure 11 9 Figure 11 10 Figure 11 11 Figure 11 12 Figure 11 13 Figure 11 14 Figure 11 15 Install WISE Firmware Uploader iii ida cada 66 Figure 11 2 Select installation GINS cloro io dead 67 gt Display installation progress ooooonnnncccccconnnnnnnnnononononnnnncncnncnccnnnnnnnnnonons 67 Figure 11 4 Figure 11 5 Figure 11 6 Complete the instalada 67 Start to remove WISE Firmware Uploader n nnoessseseeeesssssssserressss 68 Remove WISE Firmware Uploader OI 68 Remove WISE Firmware Uploader OO 68 Complete uninstalling WISE Firmware Uploader sseeeeseneeessssseeeeee 69 Launch WISE Pirmiware Uploaded ic 69 Select the WISE module POr ad gue EA 70 EN AC GICSS E 70 select the A VEER iii 71 S D OAC AMIN EE 71 Display firmware update progresg 71 Complete firmware UP Gale EE 12 http wise icpdas com 6 ICP DAS WISE User Manual 1 Introduction WISE Web Inside Smart Engine is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications WISE offers a user friendly and intuitive HMI interface that allows users to
3. PS if you are not sure your editor belongs to which system try both systems to find the accurate one http wise icpdas com 73 ICP DAS WISE User Manual 1 System Data The following table lists the Modbus address of WISE 790x system information Parameter Name Modbus Length Data Range Address Type Coils Output Unit Coil 8 Bits Coils Output Unit Coil Bitsy Input Register Unit Register 16 Bits Web Port 1 65535 Modbus TCP NetID 1 255 Modbus TCP Port 1 65535 Holding Register Unit Register 16 Bits Ethernet IP 1 Ethernet IP 2 Ethernet IP 3 Ethernet IP 4 Subnet Mask 1 Subnet Mask 2 Subnet Mask 3 Subnet Mask 4 Gateway Gateway 2 Gateway 3 Gateway 4 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 t t t t t I I I I I I I I t t t t t Int n n n n n nt n n n n n I I I K http wise icpdas com ICP DAS WISE User Manual 2 Channel Data According to the X Board modules supported by WISE 790x the Modbus Address for each module channel are listed in the following Modbus address table X Board Maximum 14 DI 13 DO 7AI gt 4 AO channel According to the channel numbers of X Board you can look up the address of the X Board channels from the following table Parameter Name Modbus Length Data Range Address Type Coils Outputs Unit Coil 8 Bits Discrete Inputs Unit Discrete Input 8 Bits http wi
4. For each module may carry different I O channels if the related DI Attribute Setting DO Attribute Setting AI Attribute Setting or AO Attribute Setting does not apply to the selected module the corresponding buttons will appear Disable The following sections will describe more detail information for these configurations 5 1 DI Attribute Setting DI Attribute setting page allows to set up detail DI channel counter configuration The configuration page is shown as below http wise icpdas com 19 ICP DAS WISE User Manual 9 2 Attribute Setting Page Module amp Channel BEE Mon RE Filter 0 x 10ms Serge initial Value Figure 5 1 DI Attribute setting page Follow the following steps Vi Specify the channel you are going to configure by selecting channel index from the dropdown list of channel field in Module amp Channel section Input Nickname for each I O channel this nickname will be displayed on the Channel Status page Input the time interval in the Filter field The time interval for filter is the minimum duration a signal has to present to make a change to the DI channel value If the signal last shorter than this filter time interval this signal change will be determined to be noise instead of a valid signal change Default Filter time interval will be O and this value must be multiples of 10ms for example a setting of 20 would mean a 200 ms filter 20 x10 ms Pleas
5. Save button to save the settings This popup window will be closed and return to the Rule settings page 6 1 3 DI Counter DI counter value can be used as evaluation criteria for IF condition statement the editing page for DI counter Condition Setting is shown as follow DI Counter Condition Setting Module Channel Save Figure 6 6 DI counter condition setting page Follow the following steps 1 Select the channel that you are going to use the value as evaluation criteria for IF condition statement Specify the channel from the dropdown list of channel field in the Module amp Channel section 11 Set up the expression statement for this counter value Select an operator from gt lt gt lt or Change If the operator is gt lt gt or lt an evaluation value has to be specified if the DI counter value match the evaluation criteria the result of this condition evaluation will be true If the operator is Change the condition will be true when there is a change to the counter value The action will be executed only once and only at the moment when DO Counter experience a change 11 Click Save button to save the settings This popup window will be closed and return to the Rule settings page http wise icpdas com A0 ICP DAS WISE User Manual 6 1 4 DO Counter DO counter value can be used as evaluation criteria for
6. gt All Programs gt ICPDAS gt WISE and then click WISE Firmware Uploader under the WISE category to start the program Kaes i j Faxes W ge IECH Accessories ICH Startup Feview EZvrew 2 Internet Explorer l EH PISO PS400 3 All Programs f ICPDAS 1 en Mavis m Eh C K WISE Firmware Uploa H U m WISE Firmware Uploader fm PISO Ps400 A ET Msi94H Figure 11 9 Launch WISE Firmware Uploader http wise icpdas com 69 ICP DAS WISE User Manual 11 3 3 Select WISE module type Select the WISE module type from the dropdown list Make sure the module type is WISE 4000 71xx amp 790x Series as shown in the following figure WISE Firmware Uploader version 2 0 AE Module Type WISE 4000 7 te and 790x Series ze Address SS q Upload Firmware About WISE Figure 11 10 Select the WISE module type 11 3 4 Set up Hardware IP Enter the IP address of the hardware device that you are going to update WISE firmware as shown in the following figure WISE Firmware Uploader version 2 0 Module Type WISE 4000 7 tox and 790x Series v SR Upload Firmware About WISE Figure 11 11 Assign IP address 11 3 5 Select WISE firmware file Click Firmware File button browse the file through the File Dialog Box to select the appropriate WISE firmware version As shown in the following figure http wise icpdas com 70 ICP DAS WISE User Manua
7. Condition statements the result of this IF THEN ELSE evaluation will be true In order to avoid signal oscillation that may result in instability to the status changes the user can set up a Deadband value for the AI channel when there is a change to the AI channel the actions will occur when this change matches the evaluation criteria value plus or minus the Deadband value The Al attribute configuration page 1s shown as below Al Attribute Setting Page Chama sp CES Figure 5 3 Al attribute setting page Follow the following steps 1 11 111 IN Specify the channel you are going to configure by selecting channel index from the dropdown list of channel field in Module amp Channel section Input Nickname for each I O channel this nickname will be displayed on the Channel Status page You can set the Deadband value of this AI channel in the Deadband field on the right side of the Deadband field the AI channel value range will be displayed For example the channel value range is 5V 5V in Figure 5 3 The default Deadband value is Q In the Scale field AI channel raw data can be set to operate with linear proportion between MIN and MAX values IF Condition will use the adjusted value in the logic Rule operation and the AI value retrieved from Modbus TCP and Web HMI would be the adjusted value The default value for MAX and MIN is 0 it mean disable the Scale
8. Using other AI channel values from the local module to compare with the AI channel value Module amp Channel ee _ Internal Register Using the internal register value to compare with the AI channel value Module amp Channel em Internal Register v 1v Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 1 2 DI DI channel value can be used as evaluation criteria for IF condition statement the editing page for DI Condition Setting is shown as below DI Condition Setting Module Channel Channel Value Save Figure 6 5 DI condition setting page Follow the following steps 1 Select the channel that you are going to use the value as evaluation criteria for IF condition statement Specify the channel from the http wise icpdas com 39 ICP DAS WISE User Manual dropdown list of channel field in Module amp Channel section 11 Define the evaluation criteria of the status in IF statement to be OFF ON ON to OFF OFF to ON or Change Once the DI channel value matches the evaluation criteria the result of this condition evaluation will be true Please note If the statement involves state transitions ON to OFF OFF to ON and Change the action will be executed only once and only at the moment when the state transition occurs 11 Click
9. lfe Ac lbb 33 UU J454 65 ICP DAS WISE User Manual 11 Firmware Update 11 1 Introduction WISE Firmware Uploader is a software tool provides a user friendly interface to easily update WISE firmware that runs on WISE hardware devices With a few clicks users could upload the latest WISE firmware to the hardware System Requirements O Operating System Windows Server 2003 Windows Server 2008 Windows Vista Windows XP O Make sure you have installed Microsoft NET Framework Version 2 0 or later E You can download Microsoft Net Framework Version 2 0 from the link below http www microsoft com downloads details aspx Fami ly ID 0 sobeacb 4362 4b0d 8edd aabl dcde04f5 amp D1 splayLang en E You can download Microsoft Net Framework Version 3 5 from the link below http www microsoft com downloads details aspx fami ly1d 3 39920FD AE92 4E39 B931 208D97D32A68 d1splaylang en 11 2 Install Uninstall WISE Firmware Uploader 11 2 1 Install WISE Firmware Uploader Follow the steps below to install WISE Firmware Uploader O Obtain the WISE Firmware Uploader setup file WISE Firmware Uploader Setup V2 0 exe O Double click the setup file to install the file you will see a window pop up as below click Next to continue WISE Firmware Uploader version 2 0 Setup Welcome to the WISE Firmware Uploader version 2 0 Setup Wizard This wizard will guide you through the installation of WISE Firmware Uploader version 2 0 is
10. 1s shown as below p Recipe Attribute Setting Page Figure 5 15 Recipe setting page Follow the following steps 1 Select the total number of Recipe you are going to use from the dropdown list of the Recipe Amount field 11 Assign an index number to the Recipe from the dropdown list of the Index field 111 Select a THEN ELSE Action from the dropdown list of the Action field IV Click the Add button A THEN ELSE Action Setting page will appear for you to set up related THEN ELSE Action Settings please refer to THEN ELSE Action V After you finish setting up THEN ELSE Action Settings the page will refresh automatically and the Actions will be listed on Recipe Recipe Attribute Setting Page o WISE 7901 X304 DOO ON 2 One Time Repeat AA WISE 7901 X304 ADO 3 5 V One Time Repeat Internal Register1 100 One Time Internal Registert 100 One Time O Repeat Joltimertstat Oe Time Sea Timer Start One Time Olsen e Figure 5 16 Recipe Action management http wise icpdas com 32 ICP DAS WISE User Manual In order to meet application requirement for some Actions WISE offers options to execute the Action one time or repeatedly Oo One Time When the IF Condition is TRUE this Action will be executed once and only once This Action will not be executed again until the IF Condition turns to be TRUE again O Repeat When the IF Condition is TRUE this Action
11. Click Save button to save the settings The popup window will closed and return to the rule settings page http wise icpdas com 43 ICP DAS WISE User Manual 6 1 8 P2P Through P2P function the data DI AI DI DO Counter or Internal Register from remote WISE controllers can be retrieved and can be incorporated into IF Condition statements To set up P2P condition Setting first of all you will need to assign an index number and specify what data you are going to use in the IF condition statements Secondly you will need to set up detail settings for the Condition settings The configuration page for setting up index and condition is shown as below P2P Condition 1 ws COMO Figure 6 11 P2P IF Condition setting page Follow the following steps 1 Assign an index number to the P2P Condition Setting from the dropdown list of the Index field 11 Specify the data for use in the Condition statements from the dropdown list in the Condition field iii Click on the button a Condition setting page will appear for setting up detail information of the Condition settings The configuration page for Condition settings is shown as below http wise icpdas com 44 ICP DAS WISE User Manual TF 01 HANS e 192 168 100 200 P2P Condition Setting index cc P2P Condition Setting SI 192 168 100 200 Remote Al Condition Setting Module amp Channel Operator DE
12. Page HTTP Save Figure 5 14 CGl Command setting page Follow the following steps 1 Specify the numbers of CGI Commands you want to set up from the dropdown list of the CGI Amount field 11 Specify the CGI group number from the dropdown list of the Index field 111 Enter the Remote Server IP Port number and CGI Command in the CGI Command field In addition 1t provides an encoded string that allow user to add current I O channel value into the CGI Command You can use the I O channel selection interface shown as above to add the I O channel encoded string into the CGI Command IV Enter the number in the Retry Count field It means the retry number WISE will try when it can t connect with Remote Server V Enter the number in the Retry Interval field It means the time interval between each retry connection The unit is Second vi Repeat steps 11 v After all CGI groups settings are completed click Save button to save the changes 5 10 Recipe Setting WISE offers up to 12 sets of Recipe setting A sequence of actions can be stored and saved in a Recipe users can setup to execute this sequence of actions that was previously stored in the Recipe when an IF condition is http wise icpdas com 31 ICP DAS WISE User Manual matched A Recipe contains a sequence of actions therefore we can say a Recipe is a macro for Actions The configuration page for Recipe Setting
13. Setn EE 18 EIERE Paria 21 gt Alattib te setting Page E 22 AI Deadband Operation gt or gt a numerical value ooooooononnnnnnn o 23 AI Deadband Operation lt or lt a numerical value oooooonnnnnnnnc 23 AI Deadband Operation a numerical valuei 24 Internal tele 29 IMEF SUN Pas da 26 Provre 5210 Schedule Le 2T Figure 5 11 Schedule Calendar setting page 28 route 5212 gt GERT 29 Figure 5 13 Email channel value encoded syntax c 0ooooooooooooooncccnnnncnnnnonnnonononononanananons 30 Figure 5 14 CGI Command Setting page 31 reeche RECIPE setting Pare 32 Figure 5 16 Recipe Action management SS La Le e CR E E E e EE 33 Figure 5 18 WISE 7100 Controller Selection ooooooooonnnnccnnnnccnnnnnnnnnnnnnnnnnnnononoos 34 Figure 5 19 Select WISE 4000 Controller 0 0000sssseesssseeceeccccecesscceeeenessseeees 35 Fisure 5 20 WISE 7901 Controller Selection cti 35 Lat e een 36 http wise icpdas com 4 ICP DAS WISE User Manual Figure 6 2 Figure 6 3 Figure 6 4 Figure 6 5 Figure 6 6 Figure 6 7 Figure 6 8 Figure 6 9 Figure 6 10 Enable rules edit rules and status display 0neenensessssoeeessssssssseeerssss 36 RUE SO ULI Dai ac bel nest 37 AlconditiOn Seto PAS ci sii ib 38 DI condition setine DAT rara A 39 DI counter condition setting page ii ti 40 DO counter condition setting D ge 41 Internal register condition Setting
14. Uploader version 2 0 Setup Wizard WISE Firmware Uploader version 2 0 has been installed on your computer Click Finish to close this wizard Figure 11 4 Complete the installation http wise icpdas com 67 ICP DAS WISE User Manual 11 2 2 Uninstall WISE Firmware Uploader Follow the steps below to uninstall WISE Firmware Uploader O Click Start gt All Programs gt ICPDAS WISE and then click Uninstall under the WISE category pag eeen eee LF tontrol Panel Paint geg KE FA Accessories a w Startup k E Internet Explorer H PISO PS5400 V All Programs fg ICPDAS Mavis e Ge o Til FR PISO PS400 E ET Ms194H D s WISE Firmware Uploa fag WISE Firmware Uploader Erview EXVNTEW Uninstall K T F TF Figure 11 5 Start to remove WISE Firmware Uploader O You will see a window pop up as below click Next to continue WISE Firmware Uploader Uninstall Welcome to the WISE Firmware Uploader version 2 0 Uninstall This wizard will guide you through the uninstallation of WISE Firmware Uploader version 2 0 Before starting the uninstallation make sure WISE Firmware Uploader version 2 0 is not running Click Next to continue Cancel Figure 11 6 Remove WISE Firmware Uploader 1 O Click Uninstall to uninstall the program WISE Finmware Uploader Uninstall Uninstall WISE Firmware Uploader version 2 0 Remo
15. com a Assign Value as x i Figure 6 8 Internal register condition setting page 41 ICP DAS WISE User Manual Follow the following steps 1 11 111 IN Select the Internal Register that you are going to use the value as evaluation criteria for IF condition statement Specify the Internal Register Index from the dropdown list of Index field Set up the expression statement for this Internal Register value W 99 99S 99 99 2099 99 Select an operator from oe Ges or lt Specify the evaluation hie If this Internal Register value match the evaluation criteria the result of this condition evaluation will be true You can compare the Internal Register with the following 3 values for condition evaluation O Self Defined value Giving a self defined value to compare with the Internal Register value index Operator a es ee O AI Channel value Using Al channel values from the local module to compare with the Internal Register value os DE See Internal Register Using other internal register value to compare Value _ _ with the Internal Register value Te Operator Internal Register v E Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 1 6 Timer Timer condition can be used as evaluation criteria for IF condition statement th
16. function Repeat steps 1 iv After all AI Channel settings are completed click Save button to save the changes http wise icpdas com 22 ICP DAS WISE User Manual There are three operation styles for AI Deadband Detail description is as below The AI Channel setting in following examples is OMA 20mA 1 When AI gt or gt a numerical value Assuming the Deadband value is set to be 2 mA and the following statements are defined in the related logic Rule IF AIO gt 10mA THEN DO ON ELSE DO OFF that means when AIO receives a signal that exceed 10mA the DO channel will change to ON immediately however when the AIO channel value drops and becomes lower than 10mA the DO channel will not change back to OFF immediately until the value reaches 8mA 10mA minus the Deadband value 2mA as shown in following figure IF Al gt 10mA THEN DO ON ELSE DO OFF lt DO 0FF ie DON ie DO O FF Figure 5 4 Al Deadband Operation gt or gt a numerical value 2 When AI lt or lt a numerical value Assuming the Deadband value is set to be 2 mA and the following statements are defined in the related logic Rule IF AI0 lt 10mA THEN DO ON ELSE DO OFF that means when AIO receives a signal which is lower than 10mA the DO channel will change to ON immediately however when the AIO channel value exceed 10mA the DO channel will not change back to OFF immediately until the value reaches 12mA 10mA plus the Deadband v
17. 1 SA E 33 O E EE 36 6 1 PEOR E 38 oe ame Os BHAA EE 47 6 3 Summary Ob The AT 57 04 Ue Mann eer a 59 Download to ee UE 62 e WploaG Reeg EE 63 9 Geer LS SEALS E 64 10 EED PENCON ennn 65 i Oe Abe Bee EE 66 LEU uer te EE 66 11 2 Install Uninstall WISE Firmware Uploader ooooooccccncccnnncnnnonnnnns 66 ILS Update WISE TMW aonan a deren 69 Appendix I Modbu us Address Table EE 73 http wise icpdas com 3 ICP DAS WISE User Manual List of Figures Pioure bell WISE Sy Stem architecte sia 7 Figure 1 2 WISE Series Products iia ins 8 Figure 2 1 The switch is located at the back of the controller AAA 10 Figure 2 2 Select Search function on MiniOS7 Ulm 10 Figure 2 3 IP Setting button on MiniOS7 Scan 11 Prstive 2 43 Network Setlines Pace alii 11 Froure sal Losimpase ot WISE Web Ulsa iaa 12 Freure 5 2 Man pace or WISE Web Uli irreenexiatne ne tee 12 Figure 3 3 WISE Web UI Operation Procedures oooooooooconnonccncnnccnnnnnnnnonononononnnannnos 13 Fis te 4 1 Name Sting Paris i 15 Figure 4 2 Figure 4 3 Figure 4 4 Figure 4 5 Figure 4 6 MD ql AAA A A enna 20 Figure 5 1 Figure 5 2 Figure 5 3 Figure 5 4 Figure 5 5 Figure 5 6 AO Atributo setas Pare iii 24 Figure 5 7 Figure 5 8 Figure 5 9 The Name location in WISE Web Page 2 0 ceeeccscccceecceeeseeeeeeeeeeeenaas 15 EE E E 16 tege EEN 17 gt X Board Module setting EE 17 Password
18. 321 or later http ftp icpdas com pub cd 8000cd napdos minios7 utility minios7_utility On toolbar select Connection gt Search shown as below A MiniOS7 Scan window will pop up and automatically start searching controllers in the network i MiniOS Utility Ferion 3 2 1 Ga File b Connection de Command E a a a a Dr eee n n n n n n n n n n n n a n n n n n New connection EZ a MN LastComnection AE Disconnect Ctrl F Search Fl Figure 2 2 Select Search function on MiniOS7 Utility http wise icpdas com 10 ICP DAS WISE User Manual After finish searching find the target controller and click TCP Broadcast and then click IP Setting button on the toolbar as shown below DAMA P Stop Options Connect Clear Help E sil me W po D TCP BroadLast 192 169 1000 235 WISE F 39010 Figure 2 3 IP Setting button on MiniOS7 Scan Click IP Setting button a network settings window will pop up Input the information and click the Set button to complete the settings T IP Setting JE Recommend Settings IP 192 168 255 1 Mask 255 255 0 0 Gateway 192 168 0 1 Alas DHEP Disable Enable E Cancel Figure 2 4 Network Settings page 9 After finish Network settings reboot the controller for the changes to take effect http wise icpdas com ICP DAS WISE User Manual 3 Website Overview Please use IE or Firefox browser t
19. AI or DI channels in the IF Condition statement they have to be pre defined in Advanced Setting first The subjects that already being defined in Advanced Setting will appear on the dropdown list of IF Condition Select the subject you want to use and then click right side button a window will pop up for you to edit detail information 6 1 1 Al AI channel value can be used as evaluation criteria for IF condition statement the editing page for AI Condition Setting 1s shown as below Al Condition Setting Module amp Channel Assign Value as x WISE 7901 X304 el Ch 0 x 0 Figure 6 4 Al condition setting page Follow the following steps 1 Select the channel that you are going to use the value as evaluation criteria for IF condition statement Specify the channel from the dropdown list of channel field in the Module amp Channel section 11 Set up the expression statement for this channel value Select an http wise icpdas com 38 ICP DAS WISE User Manual e 99 99 99 99 2099 99 operator from oe Ges or lt 11 Specify the a value If this AI channel value match the evaluation criteria the result of this condition evaluation will be true You can compare the AI channel value with the following 3 values for condition evaluation O Self Defined value Giving a self defined value to compare with the AI channel value Module amp Channel O AI Channel value
20. Action http wise icpdas com 47 ICP DAS WISE User Manual statement the editing page for AO Action is shown as follow AO Action Setting Module amp Channel Assign Value as se WISE 7901 X304 el Ch 0 0 Figure 6 15 AO action page Follow the following steps i From the dropdown list of the Module amp Channel field select the AO channel index to execute actions 11 Specify the Operator in the Operator field The 3 operators are as follow Indicate assign the new AO channel value as the value in Value field o i Indicate assign the new AO channel value as the original AO channel value plus the value in Value field o Indicate assign the new AO channel value as the original AO channel value minus the value in Value field 111 In the Value field 4 sources can be used as value O Self Defined Value giving a value defined by user Module 8 Channel Value Reg Pea deeg O AI Channel value using AI channel values from the local module Module amp Channel Value WISE 7901 X304 el ch 0 x Tnn o O AO Channel value using AO channel values from the local module Module amp Channel Value WISE 7901 X304 y Ch 0 x WISE 7901 x304 v Ch 0 v O Internal Register using value of Internal Register Module amp Channel Value ESCHER http wise icpdas com 48 ICP DAS WISE User Manual iv
21. Basic Setting section users can set up Name Setting Time Setting Ethernet Setting Module Setting and Password Setting for controllers 4 1 Name Setting Name Setting Page is for you to give your controller a name for easy recognition and identification Name Setting Page is shown as follow Name Setting Page WISE 7901 Module 1 Figure 4 1 Name Setting page If you have already given a name to this controller when you get on this page the name you previously set up will be shown on the pane After you modify or input the name click Save to save the name The name you input will appear on the top of the page as shown below Please note the Save button on Name Setting Page 1s for temporary storage only to complete the Name Setting and save the change to the controller please finish the process of Download to Module Name WISE 7901 Module 1 Figure 4 2 The Name location in WISE Web Page 4 2 Time Setting Time Setting is for setting up time on hardware devices The following figure illustrates the set up interface http wise icpdas com 15 ICP DAS WISE User Manual Time Setting Page pe CAM Daye 22 v 9 ivi 30ivig0 iv Save Time SNTP Time Server time windows Com IP or Domain Name rm Range 1 65599 Save Figure 4 3 Time setting page On every entry you make this page will display current date and time that are read from the hardware device clock You can remote
22. Click Save button to save the settings The popup window will be closed and will return to the rule setting page 6 2 2 DO You can execute an action in DO channel in the THEN ELSE Action statement the editing page for DO Action is shown as follow DO Action Setting Module 8 Channel WISE 7901 X303 Channel 0 Channel Value Save Figure 6 16 DO action page Follow the following steps i Select the DO channel to execute actions from the dropdown list of channel field in the Module amp Channel section 11 Specify the output value of DO Channel from the dropdown list of the Channel Value field The output value can be OFF ON or Pulse Output Please note to make Pulse Output option available here you have to enable Pulse Output in Advanced Setting before editing Rules Setting 11 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 3 DI Counter You can reset DI counter in the THEN ELSE Action statement the editing page for DI counter Action is shown as follow DI Counter Action Setting Module amp Channel WISE 7901 X303 el Channel 0 e Figure 6 17 DI counter action page Follow the following steps i Select the DI channel to reset DI counter from the dropdown list of channel field in the Module amp Channel section http wise icpdas com 49 ICP DAS WISE User Manual 11 Cl
23. ICP DAS WISE oy wise Manual E 790x D Serie S Version 1 26 Kay ICP DAS WISE User Manual Warning ICP DAS Inc LTD assumes no lability for damages consequent to the use of this product ICP DAS Inc LTD reserves the right to change this manual at any time without notice The information furnished by ICP DAS Inc is believed to be accurate and reliable However no responsibility 1s assumed by ICP DAS Inc LTD for its use or for any infringements of patents or other rights of third parties resulting from its use Copyright and Trademark Information Copyright 2009 by ICP DAS Inc LTD All rights reserved worldwide Trademark of Other Companies The names used for identification only maybe registered trademarks of their respective companies License The user can use modify and backup this software on a single machine The user may not reproduce transfer or distribute this software or any copy in whole or in part http wise icpdas com 9 ICP DAS WISE User Manual Table of Contents C cs AA inetd iih T S 7 2 BELO COMEN decos 10 3 Website EE 12 VAS ICS EE 15 4 1 Name SOU EE 15 AD AEO EE 15 4 3 CST AA E 17 dde IV erte E EE 17 4 5 PASS WOE SC e 18 De ACSS a 19 5 1 PLADO E rss 19 Se DOANDO Setas nna a 20 5 3 Ad PUTS E Zz JE E E uge EE EE 24 5 5 Internal Resister Setting tdci 25 MO TPO EEN 26 SE Schedule etnia ill alaicu na 21 5 8 L t 29 5 9 CGI Command Stun EN 31 LO RECIPES 3
24. IF condition statement the editing page for DO counter Condition Setting is shown as follow DO Counter Condition Setting Module amp Channel WISE 7901 X303 Channel D Figure 6 7 DO counter condition setting page Follow the following steps 1 11 111 6 1 5 Select the channel that you are going to use the value as evaluation criteria for IF condition statement Specify the channel from the dropdown list of channel field in the Module amp Channel section Set up the expression statement for this counter value Select an operator from gt lt gt lt or change If the operator is gt lt gt or lt an evaluation value has to be specified if this DO counter value match the evaluation criteria the result of this condition evaluation will be true If the operator is Change the condition will be true when there is a change to the counter value The action will be executed only once and only at the moment when DO Counter experience a change Click Save button to save the settings This popup window will be closed and return to the Rule settings page Internal Register Internal Register value can be used as evaluation criteria for IF condition statement the editing page for Internal Register Condition Setting is shown as follow Internal Register Condition Setting indes 1 Vawe http wise icpdas
25. Rule Content X X rule sequence index will appear If the rule content of the rule location is blank 1t will be specified as None To reorder a rule select the target rule from the dropdown list the corresponding Rule content X font will http wise icpdas com 60 ICP DAS WISE User Manual http wise icpdas com turn to blue from its usual black Click on Move Up Move Down buttons to move the selected rule to the desired location and then click Save to save the settings Swap Exchange the Rule content of a pair of rules Click Swap button a window as shown below will pop up Rule Swap Rule 1 Swap Figure 6 34 Rule Swap setting page From the left side drop down list select the first rule has to be previously edited and select the second rule from the right side drop down list the rule content can be blank click Save to swap the rule content Reset All Settings Reset all settings and rules already done in Basic Setting page Advanced Setting page and Rule Setting page This function is used for the requirement to restart all setting of the controller If you just want to reset all rules you can use the Reset function in Rule Manager After you click the Reset All Settings button inadvertently to reset all rules and settings you can still retrieve all settings and rules from the controller and edit them again by pressing the Upl
26. S Assign Value as Figure 6 12 P2P IF Condition detail setting page iv For detail information of Condition Setting please refer to IF Condition sections regarding DI AI DI Counter DO Counter and Internal Register v Click Save button to save the settings The popup Condition Setting page will be closed and return to P2P Condition setting page vi On the P2P Condition setting page click Save button to save the settings The P2P Condition setting page will be closed and return to the Rule Setting page 6 1 9 Rule Status The Rule Status 1f the Rule is disabled or enabled can be used as evaluation criteria for IF condition statement Please note there must be at least one edited rule on WISE controller for setting up Rule Status in the IF Condition Setting page The editing page for Rule Status Condition Setting is shown as below Rule Status Condition Setting index y san ee Figure 6 13 Rule Status IF Condition setting page http wise icpdas com 45 ICP DAS WISE User Manual Follow the following steps 1 11 111 http wise icpdas com Specify the index number of the Rule that is going to be used in the IF Condition statement from the dropdown list of the Index field Specify the Rule status to be Disable or Enable from the dropdown list of the Status field When the Rule status matches the specified status the evaluation result will be t
27. ables may no longer exist Therefore in case you make any modification please double check your settings and Rules definition to make sure no errors are present Click the Edit button the Rules Setting page will appear Deseas O THEN None H None mE None m H EA Action a a MEE Ware B Le aa Figure 6 3 Rule setting page The rule number will be displayed at the top of the page The Description field provides a space for users to make a brief description of this Rule An IF THEN ELSE Rule setting table appears under the description section Each Rule offer 3 IF conditions The user could create IF condition statements by selecting appropriate operator AND OR from the dropdown list In order to avoid possible errors the design of this table is foolproof The user has to finish setting up Condition before moving on Condition2 and so on Each Rule also offers 3 THEN actions and 3 ELSE actions More detail information will follow http wise icpdas com 37 ICP DAS WISE User Manual 6 1 IF Condition In IF Condition statement the following values or their status can be included as evaluation criteria Al DI DI Counter DO Counter Internal Register Timer Schedule P2P Rule Status K A A A A a AAA If the hardware device equips with AI or DI channel their corresponding AI or DI channel will automatically appear on the list To include subjects other than
28. ail subject in the Subject field Enter the content in the Content field The length of the content cannot exceed 160 characters In addition Email provides an encoded string that allow user to add current channel value into Email content The syntax 1s shown as below Variables are prefixed with a dollar sign to get the value of the current channel The variable type Sai Lao AO channel value aly The channel index Please note Do not do DO channel value input the un existed channel index Internal Register Figure 5 13 Email channel value encoded syntax The user can also add channel value encoded string into Email content from the I O channel selection interface Repeat steps 11 xi After all email groups settings are completed click Save button to save the changes Please note WISE 790x Email sending function can only work with the SMTP Email server that uses port 25 and must be without SSL cryptographic protocols A self hosted SMTP server is recommended for Email sending function Please visit WISE FAQ web page http wise icpdas com FAQ html for more Email setting information http wise icpdas com 30 ICP DAS WISE User Manual 5 9 CGI Command Setting WISE offers up to 12 sets of CGI Command setting This function allows sending pre input CGI Command to pre set Remote Server under certain conditions The configuration page is shown as below CGi Command Setting
29. alue 2mA as shown in following figure IF Al lt 10mA THEN DO ON ELSE DO OFF 12mA 10mA lt DO OFF gt lt DO ON _ DO OF F Figure 5 5 Al Deadband Operation lt or lt a numerical value http wise icpdas com 93 ICP DAS WISE User Manual 3 When AI a numerical value Assuming the Deadband value is set to be 1 mA and the following statements are defined in the related logic Rule IF AIO 9mA THEN DO ON ELSE DO OFF that means when AIO receives a signal between Sm A 9mA minus the deadband value ImA and 10mA 9mA plus the deadband value 1mA the DO channel will change to ON immediately However when the AIO channel value exceed 10mA or is lower than 8mA the DO channel will change to OFF as shown in following figure IF Al 9mA THEN DO ON ELSE DO OFF 10mA 9mA 8mA lt DO 0FF gt DO DO 0FF DO 0N DO 0FF Figure 5 6 Al Deadband Operation a numerical value 5 4 AO Attribute Setting AO Attribute Setting page allows to set up initial value of the AO channel The configuration page is shown as below AO Attribute Setting Page Module amp Channel WISE 7901 X304 v Channel Power On Value Figure 5 7 AO Attribute setting page Follow the following steps i Specify the channel you are going to configure by selecting channel index from the dropdown list of channel field in Module amp Channel section ii Input Nickname for each I O channel t
30. been uploaded from hardware devices to the web page you can modify and download the edited rules to the hardware devices later again http wise icpdas com 63 ICP DAS WISE User Manual 9 Channel Status Channel Status function offers an easy to view monitoring page that allows users to view important controller information in real time without SCADA software The Channel Status page is shown as below Channel Status Page DI Channel 1 0 0 0 0 0 DO Channel eeng o pp pp y D o Eo Eo Eo Eo ei META ven noo Two IW TI non wm O Figure 9 1 Channel Status page The Channel Status page will show the values of DI DO AI AO channel DIDO counter and the Internal Register If you give nicknames to the I O channels or Internal Registers the nicknames will be shown on this page as well You can modify the values of the DO AO IR channels with the value buttons on this page This page will be updated once every 10 seconds showing the latest data of the controllers http wise icpdas com 64 ICP DAS WISE User Manual 10 LED Functions Each WISE 7901D controller equips with a 5 Digit 7 segment LED display that will display network information and channel values in sequence The information is displayed as below Figure 10 1 The LED display shows network information and channel values http wise icpdas com 3 Gateway 1
31. device is power on Select the value from the dropdown list of Power On Value field The default value is OFF You can set the trigger criteria for triggering the counter to count There are three criteria HI to LOW LOW to HI and Status Change This field cannot be Disable if you want to use the counter function of this channel You can also specify the initial value of the counter in the Initial Value field This counter will start counting from the initial count value The default initial value is O If you check the Enable pulse output checkbox it will allow this DO channel to perform pulse output In Pulse Output mode the selected DO channel will generate a square wave according to specified parameters Pulse High and Pulse Low Pulse High and Pulse Low are required and has to be entered in multiples of 10ms Pulse High indicates the ON time duration and Pulse Low indicates the OFF time duration in a periodic Pulse cycle Repeat steps 1 v After all DO channel settings are completed click Save button to save the changes http wise icpdas com 21 ICP DAS WISE User Manual 5 3 Al Attribute Setting AI Attribute Setting section is for specifying a Deadband value and a scale range for the AI channel on the WISE controller As we know when the controller receives a signal from AI channel if the change of this value received matches the evaluation criteria that was previously defined in
32. dures are as follows Basic Setting Advanced Seiting Rules Setting Download to Module Figure 3 3 WISE Web UI Operation Procedures Please note DO NOT refresh the Web page when you are editing the pages otherwise the contents of all previous settings will be gone And please remember all settings will take effect only when they have been downloaded to modules if you close the Web page before finishing Download to Module all settings will be disappeared as well In addition there is a language selection menu on the left region of the main page WISE Web UI offers English Traditional Chinese and Simplified Chinese for users to choose their prefer languages The system will memorize previous language selection and will automatically switch to the previously chosen language next time when connected to the WISE Web UI Please note do not select the language during the process of Rule edition otherwise the previous edited content might disappear It is recommended to perform language selection at the beginning when connected to the WISE Web UI or after finishing Download to Module http wise icpdas com 13 ICP DAS WISE User Manual WISE 790x equips v1 20 or later firmware would upload the rule setting automatically when the web page is connected More detail information of each button will be given in the following parts http wise icpdas com 14 ICP DAS WISE User Manual 4 Basic Setting Under the
33. e editing page for timer condition setting is shown as follow http wise icpdas com 42 ICP DAS WISE User Manual Time Condition Setting T Figure 6 9 Timer condition setting page Follow the following steps 1 Select the timer that you are going to use its status as evaluation criteria for IF condition statement Specify the timer index from the dropdown list of the Index field 11 Define the evaluation criteria of the timer status in IF statement to be Not timeout or Timeout If the timer status match the evaluation criteria the result of this condition evaluation will be true 11 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 1 7 Schedule Schedule condition can be used as evaluation criteria for IF condition statement the editing page for Schedule condition Setting 1s shown as follow Schedule Condition Setting Figure 6 10 Schedule condition setting page Follow the following steps 1 Select the schedule that you are going to use its status as evaluation criteria for IF condition statement Specify the schedule index from the dropdown list of the Index field 11 Define the evaluation criteria of the status in IF statement to be Out of Range or In Range If the status of the schedule matches the evaluation criteria the result of this condition evaluation will be true lll
34. e set the trigger criteria for triggering the counter to count There are three criteria HI to LOW LOW to HI and Status Change If you select Disable indicates that the counter of this DI channel will not function You can set the initial value of the counter in the Initial Value field This counter will start counting from the initial count value The default initial value is 0 Repeat steps 1 v After all DI channel settings are completed click Save button to save the changes DO Attribute Setting DO Attribute Setting page allows to set up detail configuration of DO channel including Power On value Counter and Pulse Output You don t need to finish all configurations configure the one s according to your http wise icpdas com 20 ICP DAS WISE User Manual needs The configuration page is shown as below DO Attribute Setting Page Module amp Channel WISE 7901 X304 Channel Power On Value OFF ae Disable y Initial Value 0 Enable Pulse Output Pulse High Figure 5 2 DO Attribute setting page Follow the following steps Vi Specify the channel you are going to configure by selecting channel index from the dropdown list of channel field in Module amp Channel section Input Nickname for each I O channel this nickname will be displayed on the Channel Status page You can specify the initial status to be ON or to be OFF when the hardware
35. egister 16 Bits http wise icpdas com a7
36. emain inactive when the hardware device 1s power up 1t will not be activated until being triggered under certain conditions iv Set up the Year and Month for this Schedule execution duration When you select the start date and end date for the schedule please note the end date must be greater than the start date After you specify the Year and Month in the Date section the calendars corresponding to the Year and Month you specified will appear as shown below http wise icpdas com 27 ICP DAS WISE User Manual Vi Vil Schedule Setting Page _ Schedule Amount _ D den Eco O SCC mes eas Time o mF o mlo mlo sl 20113 20114 20115 20116 Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat 20117 20118 Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Figure 5 11 Schedule Calendar setting page Input the schedule In Range time If you specify an end time that 1s earlier than the start time such as 20 00 00 06 00 00 1t indicates the end time will be set one day after the start date On the calendars click to toggle highlight on the dates you d like to execute or not execute the operations for this Schedule If the date shows a yellow background it indicates the date is In Range that 1s that date falls into the range that will execute the operations On the contrary if the date shows a red background it
37. ernal Register value plus the value in Value field o Indicate assign the new Internal Register value as the original Internal Register value minus the value in Value field 111 In the Value field 4 sources can be used as value O Self Defined Value e a value defined by user Operator Value o 8 v 0 O AI Channel value using Al channel values from the local module Operator vl O AO Channel value using AO channel values from the local module Operator Operator CEET e O Internal Register using value of Internal Register index Operator ee SS iv Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 6 Timer You can change the Timer status to stop or to start the Timer in the THEN ELSE Action statement the editing page for Timer Action Setting is shown as below Figure 6 20 Timer action page http wise icpdas com 51 ICP DAS WISE User Manual Follow the following steps 1 Select the pre defined Timer from the dropdown list of the Index field 11 Please note the Timer you select has to be enabled in Advanced Setting 11 Specify you want to Reset or Start this Timer when this THEN ELSE Action statement is executed iv Click Save button to save the settings The popup window will be closed and return to the Rule settin
38. firmware will take effect after the reboot http wise icpdas com 72 ICP DAS WISE User Manual Appendix Modbus Address Table WISE allows you to retrieve data on hardware devices via Modbus TCP Please Note O The addresses are in Base 0 format O The addresses are listed in Decimal format O The default value of NetID is 1 and you can modify the NetID value in the Ethernet Setting page Please refer to 4 3 Ethernet Setting O The default value of Port is 502 and you can modify the Port value in the Ethernet Setting page Please refer to 4 3 Ethernet Setting O If the data is displayed in Floating format AI channel value AO channel value or Internal Register etc each record of data will take two registers to hold the data The following code example demonstrates how to join the two registers into one floating point value float register_to_float short rl short r2 float f int a amp f a rl a a EL return f Please note for the compilers are different big endian or little endian the floating point composing order might be different For example if rl represent the address of 30040 register and r2 represent the address of 30041 register to join rl and r2 to a floating point in the system is big endian system you will need to call float value register_to_float rl r2 Instead if the system is little endian system you will need to call float value register_to_float r2 r1
39. follow Password Setting Page New Passwort RE Figure 4 6 Password setting page To avoid unauthorized access and altering of data it is required for users to input password before they start to download control logic to the controllers The default password for access control is set as wise You can modify the password and password hint on this page Password length is limited to 16 characters and the password hint length is limited to 20 characters http wise icpdas com 18 ICP DAS WISE User Manual 5 Advanced Setting Advanced Setting provides additional features and allows you to perform channel configuration on hardware devices Click the Advanced Setting button a column of buttons will appear on the left of the page DI Attribute Setting DO Attribute Setting Al Attribute Setting AO Attribute Setting Internal Register Setting Timer Setting Schedule Setting Email Setting CGI Setting Recipe Setting P2P Setting K Ah A A A AAA Please note In order to avoid possible error when performing rule definition IF THEN ELSE please always finish configuration in Advanced Setting before starting to define Rules Avoid unnecessary change in Advanced Setting after you finish rule definition Unexpected errors might occur if you violate this sequence Advanced Setting Rule Setting In case you make any modification please double check your settings and Rules definition to make sure no errors are present
40. from The configuration page for WISE 7100 is shown as below Module Name WISE 7115 WISE 7117 WISE 71182 WISE 7119 WISE 7126 WISE 7144 WISE 7151 WISE 7160 WISE 7167 Figure 5 18 WISE 7100 Controller Selection http wise icpdas com 34 ICP DAS WISE User Manual 2 WISE 4000 WISE 4000 offers only WISE 4000 controller The configuration page for WISE 4000 is shown as below Module Name WISE 4000 v 3 Figure 5 19 Select WISE 4000 Controller WISE 7901 WISE 7901 can be used with ICP DAS XBoard The XBoard type you select for the remote WISE controller has to match the actual one The configuration page for WISE 7901 1s shown as below select the add on Xboard from the list Figure 5 20 WISE 7901 Controller Selection xi In the Module Name XBoard Module field select the name of the remote WISE controller from the dropdown list xil Repeat steps 11 x1 After all P2P settings are completed click Save button to save the changes http wise icpdas com 35 ICP DAS WISE User Manual 6 Rules Setting After finishing all Advanced Setting configurations the user can start to edit IF THEN ELSE rules Click the Rules Setting button a Rule Manager table will appear and the list of rules will be displayed on the left side of the page At the left side of the page the status of each rule will be displayed And at the right side of the page will show detail conten
41. g page click Save button to save the settings The P2P Action setting page will be closed and return to the Rule Setting page 6 2 12 Rule Status The Rule Status can be modified to be Disable or Enable in the Action The editing page for Rule Status Action Setting is shown as below http wise icpdas com Rule Status Action Setting index HE status Figure 6 27 Rule Status action page 55 ICP DAS WISE User Manual Follow the following steps 1 11 111 http wise icpdas com Specify the index number of the Rule It has to be a previously saved Rule that is going to be changed in the Action Condition statement from the dropdown list of the Index field Specify the Rule status to be Disable or Enable from the dropdown list of the Status field When the Action being executed the Rule status will be changed to specified status Click Save button to save the settings The Rule Status Action Setting page will be closed and return to the Rule setting page 56 ICP DAS WISE User Manual 6 3 Summary of the Rules After you finish editing all IF condition and THEN ELSE action statements for a rule return to the Rules Setting page and click Save to save all settings of this rule Please note if you want to clear previous settings after you click Clear button you have to click Save to make sure this Clear status is saved Rules Setting page is shown as bel
42. gs page 6 2 7 Schedule You can change the Schedule status to stop or to start the Schedule in the THEN ELSE Action statement the editing page for Schedule Action Setting is shown as below schedule Action Setting Figure 6 21 Schedule action setting Follow the following steps 1 Select the pre defined Schedule from the dropdown list of the Index field Please note the Schedule you select has to be enabled in Advanced Setting 11 Specify you want to Disable or Enable this schedule when this THEN ELSE Action statement is executed 11 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 8 Email You can send a message to an Email group when executing a THEN ELSE Action statement the editing page 1s as below http wise icpdas com 52 ICP DAS WISE User Manual Email Action Setting Email Information Subject Alarm 1 ist Receiver Email Address 2nd Receiver Email Address srd Receiver Email Address 4th Receiver Email Address 5th Receiver Email Address service micpdas com Figure 6 22 Email action page Follow the following steps 1 Select the pre set Email group from the dropdown list of the Index field The Email group information will be displayed for you to verify 1f this 1s the Email group you are going to send the message to 11 Click Save button to save the settings The popup wind
43. his nickname will be displayed on the Channel Status page lll You can set the initial value of the AO channel in the Power On http wise icpdas com 24 ICP DAS WISE User Manual 5 5 Value field The hardware device will output this value when is power on The default initial value is 0 iv Repeat steps i ii After all AO Channel settings are completed click Save button to save the changes Internal Register Setting WISE provides 48 Internal Registers they can be used to hold temporary variables and to read write data via Modbus address The configuration page is shown as below internal Register Setting Page E No 07 E No 08 Nick LESCH C Initial Value fo MINo 15 EA fl E No 17 E No 20 E No 21 E No 22 E No 23 E No 24 Nick J initial Value o b oo EAR ST a E S Nickname EA E 1 inital Vaive e oo e o o o ES MNo32 MNo33 MNo34 MNo35 MNo36 Enable MNo 31_ E O D K Lenz non mNo30 i E e a Wl Value Save Figure 5 8 Internal Register setting page Follow the following steps i A checkbox appears in front of each Internal Register check the checkbox to enable the Internal Register or check the checkbox in the Enable field to enable all Internal Register in the same row also Input a value if you want to set a default value that the Internal Register and set the nicknames for the Inte
44. ick Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 4 DO Counter You can reset DO counter in THEN ELSE Action statement the editing page for DO counter Action is shown as below DO Counter Action Setting WISE 7901 X303 Channel D ze Figure 6 18 DO counter action page Follow the following steps 1 Select the DO channel to reset DO counter from the dropdown list of channel field in the Module amp Channel section 11 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 5 Internal Register You can modify the value of Internal Register in the THEN ELSE Action statement the editing page for Internal Register Action Setting 1s shown as below Internal Register Action Setting 0 Save Figure 6 19 Internal Register action page Follow the following steps 1 Select the pre defined Internal Register from the dropdown list of the Index field Please note the Internal Register you select has to be enabled in Advanced Setting 11 Specify the Operator in the Operator field The 3 operators are as follow Indicate assign the new Internal Register value as the value in Value field http wise icpdas com 50 ICP DAS WISE User Manual o i Indicate assign the new Internal Register value as the original Int
45. implement control logic on controllers just a few clicks away no programming is required With this powerful and easy to use software it will minimize the learning curve shorten time to market and dramatically reduce the labor and cost spent on system development WISE system architecture 1s shown as below P R SC Kal IP Camera Email gt SMS Modbus TCP 2 THEN E se Rule E ngin Rule Editing S pr e TWE Taaa SI B A were G G Qe Pulse Frequency On Off Switch Warning light RTD sensor thermometer Figure 1 1 WISE system architecture Through Web browser users can access Web Server on ICP DAS WISE controllers to perform tasks such as logic edition and download A Rule Engine will be set up to manage and deploy rules for controllers The Rule Engine will check whether the rules are valid or not and determine the execution of actions under specific conditions for examples setting up I O channel values perform scheduled tasks sending Email or sending SMS message under a specific condition In addition through the Modbus TCP Protocol it enables SCADA software to control and monitor I O channel or system status on controllers in real time http wise icpdas com 7 ICP DAS WISE User Manual WISE system features IF THEN ELSE logic rules execution ability WISE controller equips with an IF THEN ELSE logic Rule Engine it offers up to 36 IF THEN ELSE rules for users to set up the logic conte
46. indicates that date is Out of Range that is that date falls out of the range and will not execute the operations By default all dates will be In Range that 1s during the date range you select the operation will be executed every day Clear All button is used to reset all dates to be In Range whereas Mark All button is for marking all dates to be Out of Range The Weekday button is for you to select all Mondays to Fridays to be In Range and Saturdays and Sundays to be Out of Range that is the operations will be executed during weekdays only On the contrary the Weekend button is for you to set all Saturdays and Sundays to be In Range and all Mondays to Fridays to be Out of Range that is the operations will be executed during weekends only Repeat steps 11 vi After all schedule settings are completed click Save button to save the changes http wise icpdas com 28 ICP DAS WISE User Manual 5 8 Email Setting WISE supports up to 12 Email messages This function allows sending pre input Email message s to pre set Email receiver s under certain conditions The configuration page is shown as below E mail Setting Page SMTP Server IP or Domain Name Sender Name Sender Email Address 1st Receiver Email Address 2nd Receiver Email Address 3rd Receiver Email Address 4th Receiver Email Address 5th Receiver Email Address
47. l WISE Firmware Uploader version 2 0 Module Type WISE 4000 71xx and 790x Series Y IP Address 192 168 255 1 Upload Firmware Select a HEX file Look in ze User_Files D DEBCS73_AUDIO L 2 P5400_Setup_23F My Recent P5400_ 31RevI Documents AEST RT Desktop My Documents My Computer File name WISE 4000Dv114 My Network Files of type Hex Files hex v Cancel Figure 11 12 Select the WISE firmware 11 3 6 Upload WISE firmware program Click Upload Firmware button to start update WISE firmware to the hardware device WISE Firmware Uploader version 2 0 Module Type WISE 4000 71x and 790x Series IP Address 1 92 168 255 1 C AWISE 4000Dv114 HEN Upload Firmware About WISE Figure 11 13 Upload firmware The status of WISE firmware update progress will be shown as below Package Installation Status Installing File le t ao htm Figure 11 14 Display firmware update progress When completing update of the WISE firmware a pop up window will appear to inform the user Close the window to finish firmware upload http wise icpdas com 71 ICP DAS WISE User Manual Information EN Firmware Upload Successful Figure 11 15 Complete firmware update 11 3 7 Module reboot automatically After complete the firmware update process WISE module will automatically reboot The new updated
48. llowing figure illustrates the configuration interface Ethernet Setting Page CO Obtain an IP address automatically DHCP Connection Mode Y e Specify an IP address Figure 4 4 Ethernet setting page Each time when you enter this page 1t will display current network configuration and Modbus settings that are automatically read from the hardware devices For Ethernet settings you can select Connection Mode as Obtain an IP address automatically DHCP to let the controller to get the IP from DHCP server or select Specify an IP address to modify the IP Mask Gateway DNS configuration of the controller manually You can also modify the web server port the Modbus TCP NetID and the Modbus TCP Port in the same way Please note if you make any modification to the network configuration the hardware device will reboot itself and re connect to the web page automatically about 5 seconds later 4 4 Module Setting Module Setting page allows users to select the module type for the plug in X Board as shown below Module Setting Page Save Figure 4 5 X Board Module setting page http wise icpdas com 17 ICP DAS WISE User Manual 4 5 Please select the corresponding X Board module type from the drop down list and save the settings Password Setting Password Setting allows users to change the password and password hint for access control when download logic rules The Password Setting page is as
49. ly modify the date time of the hardware device clock here After you finish modification click Save to save all changes to the hardware devices WISE 790x also has the ability to sync the clock to an SNTP time server for time synchronization through the network The Time Synchronization Setting 1s shown as follow 1 Inthe Sync Interval field select the time interval to specify how often will the WISE 580x automatically connect to SNTP time server for time synchronization through the network If you select disable it means the time synchronization function will not be performed 11 Inthe SNTP Time Server field input the IP address or domain name of the SNTP Time Server Please refer to the link time windows com this is a standard SNTP server from Microsoft for Windows operating system to synchronize the system time i In the Port field input the port number which the SN TP time server open for connection the default port number will be 123 After all settings are completed click Save button to save the changes And please remember all settings will take effect only when they have been downloaded to modules 1f you close the Web page before finishing Download to Module all settings will be disappeared as well http wise icpdas com 16 ICP DAS WISE User Manual 4 3 Ethernet Setting Ethernet Setting allows you to perform network configuration on hardware devices The fo
50. nt After completing rule edition and downloading rules to the WISE controller the Rule Engine will loop execute the rules in accordance with the execute order under specific conditions No programming is required to implement logic content on controllers WISE provides user friendly Web UI pages for editing control logic on the controllers It enables to implement logic edition by a few clicks on the mouse to set up and deploy logic rules without writing a single line of code No extra software tool is required all operations can be done through the Web browsers WISE HMI interface runs on regular Web browsers To edit control logic it only requires a browser to connect to the Web server on WISE controller No extra software tool installation is needed on the target PC 9 Support various hardware controllers that are with different I O types The wide range of I O function modules ICP DAS provided allows users to find best solutions that meet their requirements Please refer to the following table for modules and functions Functions Without Display With Display Analog Input Modules Multi Function I O WISE 71xx Digital I O Series Relay Output amp Digital Input I O Expansion Boards WISE 7901 WISE 7901D SMS WISE 4000 WISE 4000D Figure 1 2 WISE Series Products Provide Timer and Schedule operation WISE features two kind of timing functions Timer and Schedule It allows user to schedule specific date or time fo
51. o connect to Web server on WISE controller In order to get a better operation experience 1280x1024 resolution is recommended The main page of WISE controller Web page 1s shown as below Submit PL Welcome to ICP DAS WISE web configuration page Hardware Mtormadon WISE Engine Version 1 20 OS Version 2 049 Module Name WISE 7901 Di channels 6 DO channels 17 Al channels A AO channels 0 SS ome ae AAN sn lt ET A Dy OI autor Fi CAUTE td Basic Setting Set up Time Ethernet and Module type Figure 3 1 Login page of WISE Web UI You will be required to enter the password to login into the page before performing logic settings The login section is on right upper corner and the default password is After login the main web page of WISE controller is shown as below Welcome to ICP DAS WISE web configuration page Hardware formation WISE Engine Version OS Version Module Name Di channels DO channels Al channels AO channels SC see Basic Setting Set up Time Ethernet and Module type Figure 3 2 Main page of WISE Web UI http wise icpdas com 12 ICP DAS WISE User Manual Six buttons will appear on the upper part of the Web page Basic Setting Advanced Setting Rules Setting Channel Status Upload from Module Download to Module The main page will display the WISE firmware version information module information and general operating procedures The proce
52. oad from Module button 61 ICP DAS WISE User Manual 7 Download to Module Download button allows you to download edited rules from Web UI to hardware devices Click the Download to Module button the download process will be started Current download progress will be displayed as below Downloading Do not close this window 0 Figure 7 1 Showing download progress When the download process is finished the popup window will notify the user the saving process 1s completed The download process is completed 100 Figure 7 2 Message showing a successful download Close the popup window and go back to the Rules Setting window About 3 seconds after the download is completed the hardware device will automatically reboot and start to run the rules that have been downloaded At this time you can still edit or modify the content of the rules http wise icpdas com 62 ICP DAS WISE User Manual 8 Upload from Module Upload button allows you to retrieve Rules Setting information from the hardware devices and edit them at this Rules Setting page Click Upload from Module to start the upload process When the upload process is finished the window showing progress status will notify the user the process is completed The upload process is completed 100 Figure 8 1 Message showing a successful upload Click close to close the upload process window to finish upload Now the rules have
53. ow Rules Setting Page ELSE Condition Internal Regist Action1 Action1 Eat Condon nema Regter x Aatom E o Repeat A Timer y Action2 po Court al Action2 ja One Ti Ze EE z ao Figure 6 28 Clear Save Rules Each time you finish editing a Rule will go back to the Rules Setting main page All statements of edited Rules will be displayed Rules Setting main page is shown as below PR Overview Rule bec Description Delete DI Channel0 ON gt Timer1 Start Swap Reset All Settings Enable Edit Status el Skala PARAR H Rule 3 Enable Description Internal Register triggers AO Channel setting Internal_register1 111 AND register 222 Rule 6 Rule 7 Rule 8 Rule 9 Rule 10 Rule 11 Rule 12 Rule 13 Rule 14 Rule 15 Rule 16 Rule 17 Rule 18 lt IF gt lt THEN WISE 7901 X304 AO0 0 5 V DD DD DD DDR ISIgIgIgIeIelglRlRlllglelele Rule 19 Figure 6 29 Rule setting main page http wise icpdas com 57 ICP DAS WISE User Manual Click Rules Setting button to display detail rules description Rules can be downloaded to the hardware device immediately after you successfully set up one or more rule s http wise icpdas com 58 ICP DAS WISE User Manual 6 4 Rule Manager The Rule Manager allows easy modification and deployment with existing rules B
54. ow will be closed and return to the Rule settings page 6 2 9 CGI You can send a CGI Command to a Remote Server when executing a THEN ELSE Action statement the editing page 1s shown as below CGI Action Setting reien A Figure 6 23 CGI Command action page Follow the following steps i Select the pre set CGI Command action from the dropdown list of the Index field Please note the CGI Command Index you select has to be enabled in Advanced Setting 11 Click Save button to save the settings The popup window will http wise icpdas com 53 ICP DAS WISE User Manual be closed and return to the Rule settings page 6 2 10 Recipe You can execute a Recipe action in THEN ELSE Action statement the editing page for Recipe Action is shown as follow el Recipe Action Setting Figure 6 24 Recipe action page Follow the following steps 1 Select the pre set Recipe action from the dropdown list of the Index field Please note the Recipe Index you select has to be enabled in Advanced Setting 11 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 11 P2P Through P2P function the data DO AO or Internal Register from remote WISE controllers can be incorporated into THEN ELSE Action statements To set up P2P Action Setting first of all you will need to assign an index number and specify
55. ow will pop up Bue ee Cl Rule 1 Rule 2 Rule 3 Rule 4 Figure 6 32 Rule Reset setting page Rules that are previously edited will be listed on the page select the rule to be cleared and then click Save button the rule you select will be reset Reorder reorder existing rules Click Reorder button a window as shown below will pop up Rule Reorder MATA None v D El Rule 1 Rule 2 Rule 3 Rule 4 Rule 5 Rule 6 Rule 7 Rule 8 Rule 9 Rule 10 Rule 11 Rule 12 Rule Content 1 Rule Content 2 Rule Content 3 Rule Content 4 None None None None None None None None Rule 13 None Rule 14 None Rule 15 None Rule 16 None Rule 17 None Rule 18 None Rule 19 None Rule 20 None Rule 21 None Rule 22 None Rule 23 None Rule 24 None Rule 25 None Rule 26 None Rule 27 None Rule 28 None Rule 29 None Rule 30 None Rule 31 None Rule 32 None Rule 33 None Rule 34 None Rule 35 None Rule 36 None Figure 6 33 Rule Reorder setting page A menu will appear at the top of the page it contains a drop down list for selecting the target rule and a pair of Move Up Move Down buttons to move target rule to the desired location All rule locations will be listed in sequence currently support 36 rule locations If the rule content of a specific rule location has been previously edited
56. page ooooonnncnnnnncnnnnnnnonnnnnnnnnnnnonaninennss 41 Ru Condition setine Paren caida 43 Schedule condition setine Par 43 Freute 6 11 P2P IF Condition setting Paren ci does neiiiaciaie n s 44 Figure 6 12 P2P IF Condition detail setting page 45 Figure 6 13 Rule Status IF Condition setting page 45 Figure 6 14 One Time Action amp Repeat Action tems oooocnnnnnnnnnnnnncnnnnnnnnnos 47 Lee ER aC opa E 48 Proure odo DO AC On Pace aa a a a 49 Fisure 6 17 e DI counter acton page ci iia 49 Frietre0 18 DO COUMter ACUON PAT a EEEE 50 Figure 6 19 Internal Register action EE ee ee Dee 50 Ficu 6 20 gt Timer acom pare nin 51 Fisure 6 21 Schedule action s ting irc dial 92 Proute 6 27 gt GE ACUDA A 53 Preure 6 23 COT Command action EE 53 Protire 0 24 Recipe ee RE 54 Pistite 6 23 PZPaChon Patan don 54 Fisure 6 26 P2P action detail setting E 55 Figure 627 E Ee ee ee 55 Le TEEN 57 Figure 6 29 Rule setting Main page 57 Ficure 6 30 Rule Manager setine Dat Ai 59 Figure 6 31 R le Copy EH A 59 Figure 6 32 Rule Reset set ne Pace uti 60 Figure 6 33 Rule Reorder setting page cccccccccccssssssseeccccceeaeeesseeccceeeeesaaaseeeeeeess 60 Figure 6 34 gt R le Swap EELER 6l Figure 7 1 Showing download progress ccccccccssseessseececceecaeeesseeeceeeeeeaaaeseeseeeess 62 Figure 7 2 Message showing a successful download 62 Figure 8 1 Message showing a successful upload
57. r control logic execution or perform specific tasks such as time delay http wise icpdas com 8 ICP DAS WISE User Manual Real time remote alarm via SMS or Email and CGI command sending functions WISE supports SMS Email and CGI command sending functions SMS and Email functions are important functions for real time message communication The sending action can be added to the logic edition as part of logic control to provide real time message transmission function or sending CGI command for device control in response to specific events Fully P2P function between WISE controllers WISE offers P2P function that enables WISE controllers to directly communicate with other remote WISE controllers on networks All WISE controllers can freely share their status information such as I O channel value DI DO Counter or Internal Register to each others The P2P operations can be incorporated into WISE logic rules as Condition statements or Action statements for Condition evaluation criteria or Action executions Recipe function for Group Action operation WISE provides Recipe function that allows to execute a sequence of actions previously saved in the Recipe to response to IF THEN ELSE logic rules Conditions Different Recipe sets can be edited to meet various requirements for different applications 9 Real time monitoring system status of controllers WISE supports Modbus TCP Protocol for users to perform real time monitoring and cont
58. recommended that you close all other applications ore starting Setup This will make it possible to update want sys i boot your lo ng ill tem Files without having to reboot y WARNING Before you install backup you customized Files because they will be overwritten Click Next to continue Figure 11 1 Install WISE Firmware Uploader http wise icpdas com 66 ICP DAS WISE User Manual O Choose the installation location to install WISE Firmware Uploader Click Install to start the installation 5 WISE Firmware Uploader version 2 0 Setup Choose Install Location Setup will install WISE Firmware Uploader version 2 0 in the following Folder To install in a different Folder click Browse and select another Folder Click Install to start the installation Destination Folder EM ICPDASYWISE Firmware Uploader Space required 426 0KB Space available 4 7GB 11 5 24 at FFI 8 1 Figure 11 2 Select installation directory O The installation progress will be shown as below please wait till the installation is completed 5 WISE Firmware Uploader version 2 0 Setup Installing Please wait while WISE Firmware Uploader version 2 0 is being installed Output Folder C WINDOW S system32 BRRRRRRRRRRRR Figure 11 3 Display installation progress Oo When the installation is completed click Finish to close the process 6 WISE Firmware Uploader version 2 0 Setup Completing the WISE Firmware
59. rnal Register this nickname will be displayed on the Channel Status page http wise icpdas com ICP DAS WISE User Manual li After you finish all the Internal Registers selections and settings click Save button to save the settings 5 6 Timer Setting WISE provides 12 groups Timer for timing functions The Timer status can be Not Timeout or Timeout They can be included in the IF Condition statements The Timer Action can be Start or Reset The Start Action will start to run the Timer and if the Start Action is triggered one more time when the Timer is running the Timer will restart again The Reset action will reset the Timer and stop running the Timer The Timer will be in Timeout status only when the Timer is running and reached the setting time otherwise the status of Timer will remain in Not Timeout The Timer setting interface is shown as below Figure 5 9 Timer setting page Follow the following steps i Timer Amount field is required Select the total number of timer you are going to use from the dropdown list ll Specify the timer you want to set up by selecting its index number from the dropdown list of the Index field lll Period field is required for each timer please input the period interval in units of seconds iv Specify the initial status of each timer from the dropdown list of the Initial Status field Select Start indica
60. rol of the controllers Please refer to Appendix 1 for the mapping table of controller system information and Modbus TCP protocol Address In addition WISE provides an easy to view HMI web interface for real time monitoring It allows users to get important real time system information even without SCADA software Password protection for access control when download logic rules WISE HMI web page offers password protection it allows users to modify the password for access control when download the logic rules This document is intended to give you a full range instruction to WISE 790x WISE 790xD controllers You will be able to learn how to edit logic of the rules and how to download the rules to the controllers for conditional execution http wise icpdas com 9 ICP DAS WISE User Manual 2 Before Connection Before connecting to WISE Web HMI pages please complete the following steps for network configuration The network configuration of the controllers has to be set up for users to connect to Web server on WISE controllers Please make sure the Init Normal switch on the controller has been switched to Normal position Connect the controller to power supply and to the network The Init Normal switch position is shown as below Figure 2 1 The switch is located at the back of the controller Install and execute MiniOS7 Utility MiniOS7 Utility can be downloaded from the following link please download version v
61. rue Click Save button to save the settings The Rule Status Condition Setting page will be closed and return to the Rule setting page 46 ICP DAS WISE User Manual 6 2 THEN ELSE Action In the THEN ELSE Action statement the following values or status can be included AO DO DI Counter DO Counter Internal Register Timer Schedule Email CGI Recipe P2P Rule Status K A A A A AAA AAA Select the component for Action statement from the combo box and then click the right side button a window will pop up for you to edit detail information The THEN Action statement will be executed only when the result of IF condition statement is found true otherwise the ELSE Action statement will be executed In order to meet application requirement for some Actions WISE offers options to execute the Action one time or repeatedly O One Time when the IF Condition is TRUE this Action will be executed once and only once This Action will not be executed again until the IF Condition turns to be TRUE again O Repeat when the IF Condition is TRUE this Action will be executed repeatedly until the IF Condition turns to be FALSE PA A ELSE Rule Status x B Action1 E None x al z z a e operator NET a Figure 6 14 One Time Action amp Repeat Action Items 6 2 1 AO You can execute an action in AO channel in THEN ELSE
62. se icpdas com 75 ICP DAS WISE User Manual DI Ch 13 10033 0 OFF 1 ON Input Register Unit Register 16 Bits By Channel AI Ch 0 30020 2 Float l Type Setting By Channel AI Ch 1 30022 2 Float Type Setting By Channel AI Ch 2 30024 2 Float Type Setting By Channel AI Ch 3 30026 2 Float Type Setting By Channel AI Ch 4 30028 2 Float Type Setting By Channel AI Ch 5 30030 2 Float Type Setting By Channel AI Ch 6 30032 2 Float Type Setting DI Counter 0 30060 0 65535 DI Counter 1 30061 0 65535 DI Counter 2 30062 0 65535 DI Counter 3 30063 0 65535 DI Counter 4 30064 0 65535 DI Counter 5 30065 0 65535 DI Counter 6 30066 0 65535 DI Counter 7 30067 Int 0 65535 DI Counter 8 30068 Int 0 65535 DI Counter 9 30069 Int 0 65535 DI Counter 10 30070 Int 0 65535 DI Counter 11 30071 Int 0 65535 DI Counter 12 30072 Int 0 65535 ine 0 65535 ju ju ju om Oom om Int mm om ju ju Oom om om http wise icpdas com 76 ICP DAS WISE User Manual DO Counter 12 30202 0 65535 Holding Register Unit Register 16 Bits By Channel AO Ch 0 40020 2 Float Type Setting By Channel AO Ch 1 40022 2 Float l Type Setting By Channel AO Ch 2 40024 Z Float Type Setting By Channel AO Ch 3 40026 2 Float l Type Setting 3 Internal Register Data This table stores 48 sets of Internal Register data provided by WISE controller Parameter Name Modbus Length Data Range Address Type Holding Register Unit R
63. t of each rule that was previously defined by the users The rule setting page is shown as below Rule Overview Rule Manager Copy Delete Reorder Swap Reset All Settings Enable No Edit Figure 6 1 Rules setting page On the left side of the page a Rule Manager table will appear at the top of the page It provides the Copy Reset Reorder Swap and Reset all Setting functions More detail information for Rule Manager will follow Under the Rule Manager table the list of rule contains four items Enable No Edit Status Edit E Edit Edit Edit Figure 6 2 Enable rules edit rules and status display Enable A checkbox appears before each rule check the checkbox to enable the rule and this rule will be executed after being downloaded otherwise it will only be stored temporarily No Indicates the identification number of the rule To avoid possible error http wise icpdas com 36 ICP DAS WISE User Manual it is recommended to assign the identification number in sequence Edit Click the Edit button to edit detail logic content of the rule Status OK indicates this rule is successfully defined Error indicates there is error occurs Disable indicates this rule not be executed Please note if you make modification in Advanced Setting after finish defining the rules it might cause unexpected error due to the changes some vari
64. t the total number of P2P settings you are going to use from the dropdown list Assign an index number to the P2P setting from the dropdown list of the Index field In the IP field input the IP of the remote WISE controller that you want to communicate with In the Modbus TCP NetID field input the NetID of the remote WISE controller In the Modbus TCP Port field input the Modsbu TCP port of the remote WISE controller In the Scan Interval field input the time interval in seconds The controller will communicate with the target remote controller every specified time interval The default value is 5 seconds In the Polling Timeout field input the time in milliseconds The time for the controller to send Modbus command to the remote WISE controller and wait for the response The default value is 500 ms In the Connection timeout field input the time in seconds The time for the controller to connect with the remote WISE controller and wait for the response The default value is 3 seconds In the Disconnection Retry Interval field input the time interval in seconds The controller will try to connect with remote WISE controller every specified time interval after disconnection The default value is 5 seconds In the Module Type field select the type of the remote WISE controller The module type currently divided into three categories 1 WISE 7100 WISE 7100 offers WISE 71xx controllers to choose
65. tes the timer will start to count as soon as the hardware device is power up Stop indicates the Timer will remain off when the hardware device is power up it will not be activated until being triggered under certain conditions The default setting of initial Status 1s Stop vV Repeat steps 11 iv After all timer settings are completed click Save button to save the changes http wise icpdas com 26 ICP DAS WISE User Manual 5 Schedule Setting WISE provides 12 groups of Schedules to setup prescheduled routine tasks The status of Schedule function can be In Range or Out of Range they can be included in the IF Condition statements The Action of Schedule can be Enable or Disable Please note if the Schedule is disabled the status will be Out of Range Schedule setting page is shown as below te OO WG e ee Clear Al Weekday Figure 5 10 Schedule setting page Follow the following steps 1 Select the total number of schedule you are going to use from the dropdown list of the Schedule Amount field 11 Specify the schedule you want to set up by selecting its index number from the dropdown list of the Index field 111 Specify the initial status of each schedule from the dropdown list of the Initial Status field Enable indicates the schedule will be activated as soon as the hardware device is power up Disable indicates the schedule will r
66. ve WISE Firmware Uploader version 2 0 from your computer WISE Firmware Uploader version 2 0 will be uninstalled From the Following Folder Click Uninstall to start the uninstallation Uninstalling From C ICPDAS WISE Firmware Uploader l WISE Firmware Uploader Installer built on 2011 5 24 at FF 07 38 18 Figure 11 7 Remove WISE Firmware Uploader 2 http wise icpdas com 68 ICP DAS WISE User Manual o When the uninstall process is completed click Finish to finish the uninstallation WISE Firmware Uploader Uninstall Completing the WISE Firmware Uploader version 2 0 Uninstall WISE Firmware Uploader version 2 0 has been uninstalled From your computer Click Finish to close this wizard Figure 11 8 Complete uninstalling WISE Firmware Uploader 11 3 Update WISE firmware Please follow the six steps below to update the WISE firmware program on the hardware devices 11 3 1 Before update O Please visit WISE product web site http wise icpdas com or contact ICP DAS service to obtain the latest version of the WISE firmware program Copy the file to the computer that you previously installed WISE Firmware Uploader O Connect the hardware device that you are going to update WISE firmware to the network Please verify and make a note of the hardware device IP address you will need it later in the process 11 3 2 Execute WISE Firmware Uploader O Taking Windows XP as an example click Start
67. what data you are going to use in the Action statements Secondly you will need to set up detail settings for the Action settings The configuration page for setting up index and Action 1s shown as below P2P Action Setting 1 po ka Figure 6 25 P2P action page Follow the following steps 1 Assign an index number to the P2P Action Setting from the dropdown list of the Index field http wise icpdas com 54 ICP DAS WISE User Manual 11 111 Specify the data for use in the Action statements from the dropdown list in the Action field Click on the button an Action setting page will appear for setting up detail information of the Action settings The configuration page for Action settings 1s shown as below vil 192 168 100 246 P2P Action Setting 1 w WISE 7105 Module Action ME IS e 192 168 100 246 Remote DO Action Setting Module amp Channel WISE 7105 Channel 0 v IN yi Channel Value Figure 6 26 P2P action detail setting page For detail information of Action Setting please refer to THEN ELSE Action sections regarding DO AO and Internal Register Please note The operators and are not supported in the AO and Internal Register Actions of P2P Click Save button to save the settings The popup Action Setting page will be closed and return to P2P Action On the P2P Action settin
68. will be executed repeatedly until the IF Condition turns to be FALSE Vi All selected Actions will be listed on the Recipe page Click on the radio checkbox to select the target Action you can edit the selected Action by click on Edit button or delete the Action from the list by click on Delete button To rearrange the order of the Action click the Move Up DI or Move Down D button to move the target Action to the desired order To delete all Actions click on the Clear All button to remove all actions from the list vil Repeat steps 11 vi After all Recipe settings are completed click Save button to save the changes 5 11 P2P Setting WISE supports up to 8 P2P Setting This function enables WISE controllers to communicate with other remote controllers directly The remote controllers can freely share their data such as I O value DI DO Counter or Internal Register status information with local WISE controller The configuration page is shown as below P2P Setting Page Modbus TGP Neti Modbus TCP Port 5 Sec Range 0 65535 Polling Timeout 500 millisecond s Range 1 10000 Connection Timeout 3 Sec Range 0 65535 Disconnection Retry Interval 5 Sec Range 3 65535 Module Type Module Name WISE 7126 v Save Figure 5 17 P2P setting page http wise icpdas com 28 ICP DAS WISE User Manual Follow the following steps 1 11 111 IN V1 Vil Vill 1X Selec
69. y a few simple steps users can easily change the rule orders or make modification with previously edited rules The Rule Manager table is shown as below Rule Manager Copy Reorder Delete Swap Reset All Settings Figure 6 30 Rule Manager setting page Rule Manager offers 5 functions Copy Copy the content of previously edited rule to another rule Click Copy button a window as shown below will pop up Ve Rule Copy Copy to HC Rule 1 Rule 5 Rule 9 E Rule 13 HC Rule 17 HC Rule 21 1 Rule 25 E Rule 29 HF Rule 33 Rule 2 Rule 6 C Rule 10 Rule 14 Rule 18 HC Rule 22 Rule 26 Rule 30 Rule 34 HC Rule 3 HC Rule 7 Cl Rule 11 E Rule 15 HC Rule 19 CL Rule 23 C Rule 27 Cl Rule 31 Rule 35 Rule 4 Rule 8 O Rule 12 Rule 16 Rule 20 Rule 24 Rule 28 HC Rule 32 Rule 36 Figure 6 31 Rule Copy setting page Select the source rule from the first field and then select the destination s from the second fields multiple rule destinations is allowed Click Save button to copy the content of the source rule to all destination rules http wise icpdas com 59 ICP DAS WISE User Manual Reset allows to clear rule content of previously edited rules Click Reset button a window as shown bel