1. Ver 01 08 00 or later of the standard monitor OS of the GT10 is applicable 2 WVer 01 11 00 or later of the standard monitor OS of the GT10 is applicable 3 Ver 2 91V or later of GT Designer2 is applicable 7 2 Password reset function on the GOT When reading out the project data from the memory loader if the password is set in the project data password entry screen will appear on the GOT After entering the password password is reset by pressing the ENT key on the screen The data will be transferred from the GOT to the memory loader The operation procedure is described below When this function is used Ver 01 08 00 or later of the standard monitor OS of the GT10 is required 1 When the upload is started password entry screen will appear on the GOT Touch the INPUT key GTIC LDR _ Info Password reguired INPUT 2 After inputting password touch the ENT key 3 When the password matches a message notifying Password correct is display Touch the button to close the screen GTIC LDR Into JESC Password correct When the password does not match an error message is displayed If button is touch it returns to the password input screen again PASSHIORD 13 INCORRECT After all data in the memory loader is deleted only the project data and resource data in the GOT are read out to the memory loader 4 It takes longer time to transfer the font data than to transfer the standard mo
2. POWER green 2 3 Communication Specifications Item Specifications Conforming to RS232 Transmission speed 115 200bps Connector shape MINI DIN 6Pins Male GOT communication Conforms to USB2 0 Full speed is supported Performs the conversion between USB and serial in GT10 LDR After serial conversion transmission speed is 115 200bps PC communication areas with excessive dust oily smoke conductive dusts corrosive gas salt LED SET RUN green red orange f air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or exposed Connector shape USB MINI B 5Pins Receptacle to high temperature condensation or rain and wind Not doing so can cause if ERROR green red orange 24 P S VS ificati an electric shock fire malfunction or product damage or deterioration PC Sai ei ower oupply specifications GT Designer2 Ver 2 77F or later ANR selection switch Paddle switch Item Specifications STARTUP MAINTENANCE 1 When GT10 LDR is connected to a PC via the USB hub the power supply of the Data selection switch DC5V DC4 75 to 5 25V PRECAUTIONS Z CAUTION ae m be aD o pea A yea Lovee P i l Aaa Input power supply voltage Supplied from the GOT or PC Supplied from bus e Do not disassemble or modify the memory loader A EA Fee ee ee eee On 9 Switch ALUE SW power Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the memory loader directly Doing so
3. after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 11 2 When the Data selection switch is PROJECT Project data Resource data GT1020 GT1030 Memory loader 1 Turn OFF the Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the trans
4. gt Computer Project Communication configuration GT10 LDR gt Computer Resource Memory information Computer gt GT10 LDA 0S Project lt Note gt The GT10 LDA includes a built in USB RS232 converter Therefore the following communication configuration uses RS232 as standard Details Port No Test Baudrate 115200 bps 10 To write the data from the Memory loader to the GOT 11 To read out the data from the GOT to the Memory 12 Troubleshooting The standard monitor OS communication driver font data and project data are written from the memory loader to the GOT The operation procedure is described below 10 1 When the Data selection switch is PROJECT OS Standard monitor OS Communication driver Font data Project data GT1020 GT1030 Memory loader 1 Connect the memory loader to the GOT 2 Turn ON the GOT by pressing the lower right corner of the GOT The GOT startups with OS installation screen The OS can be transferred from GT Designer2 Version2 without displaying the OS installation screen depending on the combination of the GOT and the standard monitor OS Refer to the following manual for details about OS installation screen L3 GT10 User s Manual 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to WR and select the data to be transferred and transfer direction 4 Press the ENT key to determine the dat
5. GOT OS installation screen is not active Install the data after the OS installation screen is displayed on the GOT OS installation screen isn t active 12 2 LED display on the memory loader If communication cannot be established between the GOT and a PC using memory loader confirm the following status by checking display LED in memory loader State ol Contents POWER LED POWER LED The DC5V power supply from the GOT or the personal computer is is lit normally supplied In case of no communication check the status of ERROR LED The DC 5V power supply from the GOT or the personal computer is not supplied Check the items below POWER LED e Turn ON the power is not lit e Check the connection with the USB cable l e Check the connection with the GOT e Check that PLC is not overloaded when PLC supplies the power to the GOT connected to the memory loader State of ERROR LED Contents Green light Write protection switch ON 9 Turn OFF the Write protection switch This manual confers no industrial property rights or any rights of any other kind Green The GOT type that is set in the data to be transferred differs from that nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be flashing of the GOT to which the data is transferred held responsible for any problems involving industrial property rights which may Check the GOT type to which the memory loader is connected occur as a result of using the content
6. GT Designer2 GT Designer2 Version 0 Basic Operation Data Transfer Manual 9 2 To read out the data from the memory loader to a PC GT Designer2 Ver 2 77F or later The project data and resource data are read out from the memory loader to a PC GT Designer2 The operation procedure is described below Project data Resource data GT Designer2 Memory loader 1 Connect a PC GT Designer2 to the memory loader with USB cable supplied 2 Select the data to be uploaded in a PC GT Designer2 and read it out from the memory loader Refer to the following manual for details about operating instructions of GT Designer2 KE GT Designer2 Version Basic Operation Data Transfer Manual 10 To write the data from the Memory loader to the GOT The standard monitor OS communication driver font data and project data are written from the memory loader to the GOT The operation procedure is described below 10 1 When the Data selection switch is PROJECT OS Standard monitor OS Communication driver Font data MTSU come Project data ee GT1020 GT1030 Memory loader 1 Connect the memory loader to the GOT 2 Turn ON the GOT by pressing the lower right corner of the GOT The GOT startups with OS installation screen The OS can be transferred from GT Designer2 Version2 without displaying the OS installation screen depending on the combination of the GOT and the standard monitor OS
7. any case it is important to follow the directions for usage MOUNTING PRECAUTIONS NCAUTION e Use the memory loader in the environment that satisfies the general specifications described in GT10 User s manual Never use the product in 1 Overview GT10 LDR memory loader is the memory transfer module that reads writes the data to GT10 or between a PC GT Designer2 Ver 2 77F or later and GT10 LDR GT1020 GT1030 USB connecting cable supplied The wet bulb temperature is 39 C or less 2 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction 3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 4 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 2 2 Performance Specifications Item Specifications User memory Flash ROM 7 5Mbyte Memory Life Number of write times 100 000 times
8. in the project data password entry screen will appear on the GOT After entering the password password is reset by pressing the ENT key on the screen The data will be transferred from the GOT to the memory loader The operation procedure is described below When this function is used Ver 01 08 00 or later of the standard monitor OS of the GT10 is required 1 When the upload is started password entry screen will appear on the GOT Touch the INPUT key GTIC LDR _ Info Password reguired INPUT 2 After inputting password touch the ENT key 3 When the password matches a message notifying Password correct is display Touch the button to close the screen GT 10 LOR ESC Password correct Inte When the password does not match an error message is displayed If button is touch it returns to the password input screen again PASSHIORD 13 INCORRECT After all data in the memory loader is deleted only the project data and resource data in the GOT are read out to the memory loader 4 It takes longer time to transfer the font data than to transfer the standard monitor OS and communication driver It takes approximately 1 minute and 45 seconds to transfer Standard monitor OS Communication driver It takes approximately 8 minutes to transfer Standard monitor OS Communication driver Font data Japanese supporting Europe is installed in the GT10 before shipment from the factory It is
9. is running Switch to determine the transfer direction and the data to be transferred and to start the transfer Switch to prevent the memory loader from being written to the data Described operating instructions of the memory loader 5 LED lighting specification LED Name Status Contents Power is supplied POWER Power is not supplied Before starting the transfer The transfer direction and the data to be transferred are determined SET RUN The transfer is running The transfer is completed The transfer is aborted Write protection switch ON The GOT type that is set in the data to be transferred differs from that of the GOT to which the data is transferred ERROR i E a ine cae ponies OS is different from that of the project data Communication error occurs between the GOT and the memory loader Password is set in the project data OS installation screen is not active An error message appears on the GOT screen Apply remedies according to the display Refer to the Chapter 12 Troubleshooting for details on handling errors 6 Switch operation specification Switch Name RD WR selection switch Data selection switch Write protection switch ENT key Specifications Switch to select read write direction RD The data is read out from the GOT to the memory loader WR The data is written from the memory loader to the GOT Switch to select the data to be transferred e When reading out the data from the GOT to the m
10. monitor OS Communication driver Font data Project data 8 2 Confirmation of communication port Windows XP example follows e In Windows XP click Start Settings Control Panel gt Peformance and Maintenance System Hardware Device Manager D and the window below will be displayed Please confirm the COM number to which the USB driver is allocated COM and LPT e If using Windows 98 Windows 98SE Windows Millennium Edition or Windows 2000 A screen that is equivalent to the one below is displayed by clicking My Computer Control Panel System Device Manager in the menu of the personal computer GT Designer2 Memory loader 1 Turn OFF the Write protection switch 2 Connect a PC GT Designer2 to the memory loader with USB cable supplied 3 Write the data from a PC GT Designer2 to the memory loader e If using Windows Vista A screen that is equivalent to the one below is displayed by clicking Start Control Panel Device Manager in the menu of the personal computer Refer to the following manual for details about operating instructions of GT Designer2 E IDE ATA ATAPI controllers Loe GT Designer2 Version O Basic Operation Data Transfer Manual 5 gt Keyboards Mice and other pointing devices Monitors E Network adapters COM1 Other devices Ports COM amp LPT 9 Communications Po F
11. not necessary to transfer the font data when the used font is not changed 7 3 Error display function If an error occurs between the GOT and the memory loader during the transfer an error message will appear on the GOT screen Apply remedies according to the display ee Chapter 12 Troubleshooting Turning OFF and ON the power or touching the screen will close the error message screen When this function is used Ver 01 08 00 or later of the standard monitor OS of the GT10 is required MITSUBISHI conas ST T0 LDR Error ESC Wrong GOT model is connected Error message on the GOT A 8 Installation of Driver Setting Software When the communication between a PC GT Designer2 Ver 2 77F or later and the memory loader is performed driver installation communication port setting is required 8 1 Driver installation When the communication between a PC GT Designer2 and the memory loader is performed driver installation is required Refer to the following manual for details about driver installation cs GT Designer2 Version Basic Operation Data Transfer Manual 9 Transfer procedures between a PC and the Memory loader 9 1 To write the data from a PC GT Designer2 Ver 2 77F or later to the memory loader The standard monitor OS communication driver font data and project data are written from a PC GT Designer2 to the memory loader The operation procedure is described below Standard
12. the ENT key Failure to do so cancels the operations that have been os made oe e The second pressing of the key starts the transfer When the standard monitor OS and communication driver are transferred from the memory loader to the GOT starting up the GOT with OS installation screen is FEE required No Specifications 1 POWER LED 2 SET RUN LED 3 ERROR LED LED to show power status LED to show that the settings are being checked the transfer is running LED to show error status 4 RD WR selection switch Switch to select read write direction 5 Data selection switch Switch to select the data to be transferred 6 ENT key Switch to determine the transfer direction and the data to be transferred and to start the transfer 7 Write protection switch Switch to prevent the memory loader from being written to the data 8 USB port Connection port with a PC with protection cap 9 Reference plate operating instructions Described operating instructions of the memory loader 10 Reference plate error contents Described lighting status of ERROR LED 11 Transfer cable Cable to be connected with the GOT 12 Strap hole A hole to attach a strap 13 Part to be labeled Space to be labeled created by user 14 Rating plate Nameplate a 7 Function specification 7 1 Transfer function 1 Standard monitor OS Font data Communication driver Project data p e 2 Project data Resource data PC GT Designer
13. the directions for usage MOUNTING PRECAUTIONS CAUTION Item Specifications Conforming to RS232 Transmission speed 115 200bps Connector shape MINI DIN 6Pins Male USB connecting cable supplied Flash ROM 7 5Mbyte GOT communication Memory Life Number of write times 100 000 times Conforms to USB2 0 Full speed is supported Performs the conversion between USB and serial in e Use the memory loader in the environment that satisfies the general POWER green PC communication GT10 LDR After serial conversion transmission specifications described in GT10 User s manual Never use the product in speed is 115 200bps areas with excessive dust oily smoke conductive dusts corrosive gas salt LED SET RUN green red orange i t h p USB MINI B 5Pi R tacl air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or exposed onnector shape 5 ins Receptacle to high temperature condensation or rain and wind Not doing so can cause ERROR green red orange 2 4 Power Supply Specifications an electric shock fire malfunction or product damage or deterioration RD WR selection GT Designer2 Ver 2 77F or later f switch Paddle switch Item Specifications STARTUP MAINTENANCE 1 When GT10 LDR is connected to a PC via the USB hub the power supply of the PRECAUTIONS USB hub must be supplied by the AC adopter of the USB hub GT10 LDR connected to the USB hub may not work properly depe
14. 131 2 147 m s2 3 times each in X Y and Z directions Registration Bundled Items The company name and the product name to be described in this manual are Operating atmosphere Must be free of lamp black corrosive gas flammable gas or excessive amount of electroconductive dust particles and must be no the registered trademarks or trademarks of each company Bundled item Quantity direct sunlight Same as for saving Effective Nov 2008 GT10 LDR memory loader 1 Operating altitude 2 2000 m 6562 ft max Specifications are subject to change without notice USB cable 1m 1 Overvoltage category 3 ll or less GT10 LDR Memory loader USER S MANUAL This manual 1 Pollution degree 4 2 or less Safety Precaution Read these precautions before using Cooling method Self cooling Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage NCAUTION Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In
15. 2 Data Transfer data 3 Standard monitor OS Font data Communication driver Project data MITSUBISHI p S 4 Standard monitor OS Communication driver Project data Resource data GT1020 GT1030 Memory loader O Available to transfer x Unavailable to transfer selection switch Transfer direction Standard monitor OS Resource data Project data Communication Operation driver 1 PC GT Designer2 Memory loader O O After all data in the memory loader is deleted the data O selected with GT Designer2 is written to the memory loader all at once 2 Memory loader PC GT Designer2 The project data or resource data is read out from the memory loader to a PC GT Designer2 PROJECT 3 Memory loader gt OS All data in the memory loader is written to the GOT GOT PROJECT Only the project data in the memory loader is written to the GOT PROJECT os After all data in the memory loader is deleted all data in the GOT is read out to the memory loader 4 GOT gt Memory loader PROJECT Ver 01 08 00 or later of the standard monitor OS of the GT10 is applicable 2 Wer 01 11 00 or later of the standard monitor OS of the GT10 is applicable 3 Ver 2 91V or later of GT Designer2 is applicable 7 2 Password reset function on the GOT When reading out the project data from the memory loader if the password is set
16. 2 and Z directions product Make sure to learn all the product information safety information and For GOT1000 Series sold separately Under continuous 5 to 9Hz Loos o o n And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Shock resistance Conforms to JIS B3502 IEC 61131 2 147 m s2 3 times each in X Y and Z directions Registration Bundled Items The company name and the product name to be described in this manual are Operating atmosphere Must be free of lamp black corrosive gas flammable gas or excessive amount of electroconductive dust particles and must be no the registered trademarks or trademarks of each company Bundled item Quantity direct sunlight Same as for saving Effective Nov 2008 GT10 LDR memory loader 1 Operating altitude 2000 m 6562 ft max Specifications are subject to change without notice USB cable 1m 1 Overvoltage category s ll or less GT10 LDR Memory loader USER S MANUAL This manual 1 Pollution degree 4 2 or less Safety Precaution Read these precautions before using Cooling method Self cooling Before using this product please read this manual and the relevant manuals F o Overview 1 The wet bulb temperature is 39 C or less l hate l 1 A Manual caret and pay M aientionto sataty To Mande GT10 LDR memory loader is the memory transfer module that reads writes the data to 2 Do not use or store the GOT under pressure higher
17. 21 0 82 mm inch Weight 0 2kg 1 ROM in which new data can be written without deleting the written data Fuse Power consumption 0 7W 140mA DC5V or less 3 External Dimensions External Dimensions MITSUBISHI POWER SET RUN ERROR E om RD WR GOT gt LDR LDR gt GOT ENT _ 8 PROJECT o 405 PROJECT 2 pee N o c oi A R 2 GT10 LDR 70 2 75 WRITE PROTECT OFF ON CL a Unit mm inch Weight 0 2kg kl 28 0 LZ 4 Part Name MITSUBISHI POWER SET RUN ERROR C ie CO WR 1 LDR gt GOT 4 0S PROJECT 5 lt lt A GT10 LDR 7 8 OF ON m oS No 1 POWER LED 2 SET RUN LED 3 ERROR LED 4 RD WR selection switch 5 Data selection switch 6 ENT key 7 Write protection switch 8 USB port 9 Reference plate operating instructions 10 Reference plate error contents 11 Transfer cable 12 Strap hole 13 Part to be labeled 14 Rating plate Nameplate LED to show power status LED to show error status A hole to attach a strap Cable length Switch to select read write direction Switch to select the data to be transferred Connection port with a PC with protection cap Described lighting status of ERROR LED Cable to be connected with the GOT Space to be labeled created by user 240 9 44 Unit mm inch Specifications LED to show that the settings are being checked the transfer
18. 6 oY Printer Port LPT1 MB Processors Sound video and game controllers System devices Universal Serial Bus controllers Gi lt A Standard Universal PCI to USB Host Controller 9 2 To read out the data from the memory loader to a PC GT Designer2 Ver 2 77F or later The project data and resource data are read out from the memory loader to a PC GT Designer2 The operation procedure is described below FR Project data Resource data USB Root Hub GT Designer2 Memory loader 1 Connect a PC GT Designer2 to the memory loader with USB cable supplied 2 Select the data to be uploaded in a PC GT Designer2 and read it out from the memory loader Check following GT10 LDR is indicated at A GT10 LDR COM is indicated at B indicates Me COM number used in Memory loader Refer to the following manual for details about operating instructions of GT Designer2 GT Designer2 Version Basic Operation Data Transfer Manual Install the GT Designer2 again when is displayed Select the GT Designer2 COM number as the COM number currently assigned on the screen above 8 3 Setting GT Designer2 Click Communication Communicate with GT10 LDR Communication configuration tab Select the same COM number as the COM number of the personal computer when the setting communication port screen appears Click Update Communicate with GT10 LDR GT10 LDR
19. A JY997D29501C Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor 2 Specifications 2 1 General Specifications a MITSUBISHI Changes for the Better Item Specifications Manual Manual name Contents Number Operating ambient temperature 0 to 40 C GT10 LDR Memory loader Model Code Storage ambient temperature 20 to 60 C Describes the GT10 hardware relevant content such as part names external dimensions mounting power supply wiring specifications and introduction to USER S MANUAL Operating ambient humidity 10 to 90 RH non condensing JY997D24701 GT10 User s Manual 09R819 Manual Number JY997D29501C 10 to 90 RH non condensing Storage ambient humidity GRAPHIC OPERATION TERMINAL GOTiooo option devices sold separately Sweep Count GT Designer2 Describes methods of the GT Designer2 Under intermittent 5 to 9Hz This manual describes the part names dimensions mounting and Version2 Basic installation operation basic operation for S H 080529ENG Conforms to JIS b f Sen specifications of the product Before use read this manual and manuals of Operation Data drawing and transmitting data to 1D7M24 Vibration resistance B3502 and Veen 9 to 150Hz Seme f 10 times each in X Y relevant products fully to acquire proficiency in handling and operating the Transfer Manual GOT1000 series IEC61131
20. ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 11 2 When the Data selection switch is PROJECT MITSUBISHI Project data Resource data GT1020 GT1030 Memory loader 1 Turn OFF the Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made wil
21. R LED is not lit Power is not supplied T B POWER LED is not lit Before starting the transfer GOPLDR cor Orange light The transfer direction and the data to be transferred are determined Ke oT m S SET RUN Green flashing The transfer is running c oa 8 Green light The transfer is completed Red flashing The transfer is aborted 240 9 44 5 POWER LED is not lit No errors ight 1 Write protection switch ON V aiima Green light p TA Green flashing The GOT type that is set in the data to be transferred differs from that of the GOT to which the data is transferred 70 2 75 0 55 lt gt The data to be transferred is broken m _ 1 ERROR Red light The major version of the standard monitor OS is different from that of the project data Unit mm inch e 8 Weight 0 2kg Red flashing Communication error occurs between the GOT and the memory loader Password is set in the project data Orange Green 1 OS installation screen is not active 4 Part Name 1 An error message appears on the GOT screen Apply remedies according to the display Refer to the Chapter 12 Troubleshooting for details on handling errors MITSUBISHI 6 Switch operation specification POWER SEVRUN ERROR Switch Name Specifications on 10 Switch to select read write direction WR bei selection RD The data is read out from the GOT to the memory loader au eeser WR The data is written from the memory loader to the GOT 11 4 ie l
22. Refer to the following manual for details about OS installation screen lt 3 GT10 User s Manual 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to WR and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 10 2 When the Data selection switch is PROJECT Project data Sal GT1020 GT1030 Memory loader 1 Connect the memory loader to the GOT and turn ON the GOT 2 Set the Data selection switch to PROJECT and the RD WR selection switch to WR and select the data to be transferred and transfer direction 3 Press the ENT key to determine the data to be transferred and transfer dir
23. a to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 10 2 When the Data selection switch is PROJECT MITSUBISHI _conocs Project data GT1020 GT1030 Memory loader 1 Connect the memory loader to the GOT and turn ON the GOT 2 Set the Data selection switch to PROJECT and the RD WR selection switch to WR and select the data to be transferred and transfer direction 3 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection swit
24. can cause a memory loader malfunction or failure e When unplugging the cable connected to the GOT do not hold and pull the cable portion Doing so can cause the memory loader or cable to be PC environment In the case connect the GT10 LDR directly to the USB port on the PC The use of 100 thousand times is due for replacement operating force 2 55N 0 69N ENT key Write protection switch Slide switch Fuse Power consumption 0 7W 140mA DC5V or less External dimensions W70 2 75 xH110 4 33 xD21 0 82 mm inch 0 2kg damaged or can cause a malfunction due to a cable connection fault e Do not bent at a sharp angle or tie the memory loader cables Doing so can cause the breaking of the cables DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS Weight ROM in which new data can be written without deleting the written data CAUTION e Make sure to transport the memory loader and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail 3 External Dimensions 5 LED lighting specification External Dimensions Cable length bas A POWER LED is lit Power is supplied gt POWER POWE
25. cation driver are transferred from the memory loader to the GOT starting up the GOT with OS installation screen is required 7 Function specification 7 1 Transfer function 1 Standard monitor OS Font data Communication driver Project data eee pe ee EEEe ___ 2 Project data Resource data PC GT Designer2 Data Transfer data 3 Standard monitor OS Font data Communication driver Project data MITSUBISHI 4 Standard monitor OS Communication driver Project data Resource data GT1020 GT1030 Memory loader O Available to transfer x Unavailable to transfer selection switch Transfer direction Standard monitor OS Resource data Project data Communication Operation driver 1 PC GT Designer2 Memory loader O O After all data in the memory loader is deleted the data O selected with GT Designer2 is written to the memory loader all at once 2 Memory loader gt PC GT Designer2 The project data or resource data is read out from the memory loader to a PC GT Designer2 PROJECT 3 Memory loader gt OS All data in the memory loader is written to the GOT GOT PROJECT Only the project data in the memory loader is written to the GOT PROJECT os After all data in the memory loader is deleted all data in the GOT is read out to the memory loader 4 GOT gt Memory loader PROJECT
26. ch ON Turn OFF the Write protection switch The GOT type that is set in the data to be transferred differs from that of the GOT to which the data is transferred Check the GOT type to which the memory loader is connected The data to be transferred is broken or the major version of the standard monitor OS is different from that of the project data e Write the standard monitor OS communication driver and project data from GT Designer2 to the memory loader again and then transfer them to the GOT again e Set the Data selection switch to PROJECT OS and read out all data from the GOT to the memory loader and then transfer them to the GOT again Communication error occurs between the GOT and the memory loader e Check the connection with the communication cable e Check that power supply is stable lighting of POWER LED Password is set in the project data Reset the password with the numeric keypad on the GOT OS installation screen is not active Install the data after the OS installation screen is displayed on the GOT This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the caus
27. ch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 4 Press the ENT key again to start the transfer SET RUN LED will be green flashing 5 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring loader The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory loader The operation procedure is described below 11 1 When the Data selection switch is PROJECT OS MITSUBISHI o y Project data Communication driver Standard monitor OS Resource data Se DeGoT GT1020 GT1030 GTIGLDR Memory loader 1 Turn OFF the Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated
28. e ambient temperature 20 to 60 C USER S MANUAL Manual Number JY997D29501C GRAPHIC OPERATION TERMINAL GOTOO GT10 User s Manual Describes the GT10 hardware relevant content such as part names external dimensions mounting power supply wiring specifications and introduction to JY997D24701 09R819 option devices sold separately Operating ambient humidity 10 to 90 RH non condensing Storage ambient humidity 10 to 90 RH non condensing Sweep Count GT Designer2 Describes methods of the GT Designer2 Under intermittent 5 to 9Hz This manual describes the part names dimensions mounting and Version2 Basic installation operation basic operation for H 080529ENG Conforms to JIS i ee specifications of the product Before use read this manual and manuals of Operation Data drawing and transmitting data to D7M24 Vibration resistance B3502 and viDranon 9 to 150Hz aseme f 10 times each in X Y relevant products fully to acquire proficiency in handling and operating the Transfer Manual GOT1000 series IEC61131 2 and Z directions product Make sure to learn all the product information safety information and For GOT1000 Series sold separately Under continuous 5 to 9Hz Oo om Ard store t ana opm Ce o S And store this manual in a safe place so that you can take it out and read it E oa whenever necessary Always forward it to the end user Shock resistance Conforms to JIS B3502 IEC 61
29. e of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN JY997D29501C a MITSUBISHI Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor A 2 Specifications 2 1 General Specifications Changes for the Better Item Specifications Manual Manual name Contents Number Operating ambient temperature 0 to 40 C GT10 LDR Memory loader Model Code Storag
30. ection SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 4 Press the ENT key again to start the transfer SET RUN LED will be green flashing 5 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 11 To read out the data from the GOT to the Memory loader The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory loader The operation procedure is described below 11 1 When the Data selection switch is PROJECT OS MITSUBISHI s ga Project data B Bor x Communication driver Standard monitor OS Resource data ea MITSUBISHI comes GT1020 GT1030 GeLDR Memory loader 1 Turn OFF the Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the
31. emory loader PROJECT OS The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory loader PROJECT The project data and resource data are read out from the GOT to the memory loader e When writing the data from the memory loader to the GOT PROJECT OS The standard monitor OS font data communication driver and project data are written from the memory loader to the GOT PROJECT The project data is written from the memory loader to the GOT Switch to prevent the memory loader from being written to the data ON The data cannot be written neither from the GOT or a PC GT Designer2 to the memory loader OFF The data can be written from the GOT or a PC GT Designer2 to the memory loader Switch to determine the transfer direction and the data to be transferred and to start the transfer The transfer starts by pressing the key twice e The first pressing of the key determines the read write direction and the data to be transferred After the read write direction and the data to be transferred are determined if RD WR selection switch and Data selection switch are operated the operations that have been made will be canceled The ENT key must be pressed within 30 seconds after the first pressing of the ENT key Failure to do so cancels the operations that have been made e The second pressing of the key starts the transfer When the standard monitor OS and communi
32. fer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 12 1 GOT error message When communication between the GOT and the memory loader does not work check the following contents depending on the GOT error messages GOT error message Remedy Write protection switch is ON Write protection switch ON Turn OFF the Write protection switch The GOT type that is set in the data to be transferred differs from that of the GOT to which the data is transferred Check the GOT type to which the memory loader is connected Wrong GOT model is connected The data to be transferred is broken or the major version of the standard monitor OS is different from that of the project data e Write the standard monitor OS communication driver and project data from GT Designer2 to the memory loader again and then transfer them to the GOT again e Set the Data selection switch to PROJECT OS and read out all data from the GOT to the memory loader and then transfer them to the GOT again Corrupt data or OS version variance Communication error occurs between the GOT and the memory loader e Check the connection with the communication cable e Check that power supply is stable lighting of POWER LED Communication error GOT contains a system password Password is set in the project data Reset the password with the numeric keypad on the
33. l be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 12 Troubleshooting 12 1 GOT error message When communication between the GOT and the memory loader does not work check the following contents depending on the GOT error messages GOT error message Write protection switch is ON Remedy Write protection switch ON Turn OFF the Write protection switch The GOT type that is set in the data to be transferred differs Wrong GOT model is from that of the GOT to which the data is transferred connected Corrupt data or OS version variance Communication GOT contains a system password OS installation screen isn t active Check the GOT type to which the memory loader is connected The data to be transferred is broken or the major version of the standard monitor OS is different from that of the project data e Write the standard monitor OS communication driver and project data from GT Designer2 to the memory loader again and then transfer the
34. lect the GT Designer2 COM number as the COM number currently assigned on the screen above 8 3 Setting GT Designer2 Click Communication Communicate with GT10 LDR Communication configuration tab Select the same COM number as the COM number of the personal computer when the setting communication port screen appears Click Update Communicate with GT10 LDR GT10 LDR gt Computer Project GT10 LDR gt Computer Resource Memory information Communication configuration Computer gt GT10 LDR 05 Project lt Note gt The GT10 LDRA includes a built in USB RS232 converter Therefore the following communication configuration uses A5232 as standard Details Port No Baudrate 115200 v bps Test 9 Transfer procedures between a PC and the Memory loader 9 1 To write the data from a PC GT Designer2 Ver 2 77F or later to the memory loader The standard monitor OS communication driver font data and project data are written from a PC GT Designer2 to the memory loader The operation procedure is described below Standard monitor OS Communication driver Font data Project data GT Designer2 Memory loader 1 Turn OFF the Write protection switch 2 Connect a PC GT Designer2 to the memory loader with USB cable supplied 3 Write the data from a PC GT Designer2 to the memory loader Refer to the following manual for details about operating instructions of
35. m to the GOT again e Set the Data selection switch to PROJECT OS and read out all data from the GOT to the memory loader and then transfer them to the GOT again Communication error occurs between the GOT and the memory loader error e Check the connection with the communication cable e Check that power supply is stable lighting of POWER LED Password is set in the project data Reset the password with the numeric keypad on the GOT OS installation screen is not active Install the data after the OS installation screen is displayed on the GOT 12 2 LED display on the memory loader If communication cannot be established between the GOT and a PC using memory loader confirm the following status by checking display LED in memory loader State of POWER LED POWER LED is lit POWER LED is not lit State of ERROR LED Green light Green flashing Red light Red flashing Red amp Green Orange amp Green Contents The DC5V power supply from the GOT or the personal computer is normally supplied In case of no communication check the status of ERROR LED The DC 5V power supply from the GOT or the personal computer is not supplied Check the items below e Turn ON the power e Check the connection with the USB cable e Check the connection with the GOT e Check that PLC is not overloaded when PLC supplies the power to the GOT connected to the memory loader Contents Write protection swit
36. nding on the Data selection switch CAUTION DC5V DC4 75 to 5 25V Input power supply voltage Supplied from the GOT or PC Supplied from bus Tactile switch power Switch e Do not disassemble or modify the memory loader Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the memory loader directly Doing so can cause a memory loader malfunction or failure e When unplugging the cable connected to the GOT do not hold and pull the cable portion Doing so can cause the memory loader or cable to be damaged or can cause a malfunction due to a cable connection fault e Do not bent at a sharp angle or tie the memory loader cables Doing so can cause the breaking of the cables DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS CAUTION e Make sure to transport the memory loader and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail PC environment In the case connect the GT10 LDR directly to the USB port on the PC The use of 100 thousand times is due for replacement operating force 2 55N 0 69N ENT key Write protection switch Slide switch External dimensions W70 2 75 xH110 4 33 xD
37. nitor OS and communication driver It takes approximately 1 minute and 45 seconds to transfer Standard monitor OS Communication driver It takes approximately 8 minutes to transfer Standard monitor OS Communication driver Font data Japanese supporting Europe is installed in the GT10 before shipment from the factory It is not necessary to transfer the font data when the used font is not changed 7 3 Error display function If an error occurs between the GOT and the memory loader during the transfer an error message will appear on the GOT screen Apply remedies according to the display ee Chapter 12 Troubleshooting Turning OFF and ON the power or touching the screen will close the error message screen When this function is used Ver 01 08 00 or later of the standard monitor OS of the GT10 is required MITSUBISHI conces GT10 LDR Error ESC Wrong GOT model is connected Error message on the GOT A 8 Installation of Driver Setting Software When the communication between a PC GT Designer2 Ver 2 77F or later and the memory loader is performed driver installation communication port setting is required 8 1 Driver installation When the communication between a PC GT Designer2 and the memory loader is performed driver installation is required Refer to the following manual for details about driver installation GT Designer2 Version Basic Operation Data Transfer Manual 8 2 C
38. o Switch to select the data to be transferred e When reading out the data from the GOT to the memory loader PROJECT OS The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory loader 5 Dela sclecuen switch PROJECT The project data and resource data are read out from the GOT to the memory loader 44 e When writing the data from the memory loader to the GOT PROJECT OS The standard monitor OS font data communication driver and project data are written from the memory loader to the GOT PROJECT The project data is written from the memory loader to the GOT Switch to prevent the memory loader from being written to the data Write protection switch ON The data cannot be written neither from the GOT or a PC GT Designer2 to the memory loader OFF The data can be written from the GOT or a PC GT Designer2 to the memory loader GT10 LDR Switch to determine the transfer direction and the data to be transferred and to start the transfer The transfer starts by pressing the key twice e The first pressing of the key determines the read write direction and the data to be transferred 7 8 ENT ke After the read write direction and the data to be transferred are determined if RD WR selection switch and Data selection switch are operated y the operations that have been made will be canceled The ENT key must be pressed within 30 seconds after the first pressing of
39. onfirmation of communication port Windows XP example follows e In Windows XP click Start Settings Control Panel Peformance and Maintenance System Hardware Device Manager D and the window below will be displayed Please confirm the COM number to which the USB driver is allocated COM and LPT e If using Windows 98 Windows 98SE Windows Millennium Edition or Windows 2000 A screen that is equivalent to the one below is displayed by clicking My Computer Control Panel System Device Manager in the menu of the personal computer e If using Windows Vista A screen that is equivalent to the one below is displayed by clicking Start Control Panel Device Manager in the menu of the personal computer E IDE ATA ATAPI controllers 5 gt Keyboards gt Mice and other pointing devices Monitors B Network adapters COM1 Other devices aF Ports COM amp LPT a Communications Po F lt B aF Printer Port LPT1 Processors Sound video and game controllers System devices Universal Serial Bus controllers oem lana nananana Standard Universal PCI to USB Host Controller USB Root Hub Check following GT10 LDR is indicated at A GT10 LDR COM is indicated at B indicates the COM number used in Memory loader Install the GT Designer2 again when is displayed Se
40. s noted in this manual The data to be transferred is broken or the major version of the Warrant standard monitor OS is different from that of the project data oe Write the standard itor OS ication dri Aree Mitsubishi will not be held liable for damage caused by factors found not to be eE ee ee ee the cause of Mitsubishi opportunity loss or lost profits caused by faults in the f data from GT Designer2 to the memory loader again and then ae i i Red light t i Mitsubishi products damage secondary damage accident compensation ransfer them to the GOT again f i i Sa s caused by special factors unpredictable by Mitsubishi damages to products e Set the Data selection switch to PROJECT OS and read out all other than Mitsubishi products and to oiher duties data from the GOT to the memory loader and then transfer them MSUIS AI poe i to the GOT again Communication error occurs between the GOT and the memory A For safe use loader Red flashing Check the connection with the communication cable e This product has been manufactured as a general purpose part for general e Check that power supply is stable lighting of POWER LED industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Rede G Password is set in the project data e Before using the product for special purposes such as nuclear power electric ede sreen Reset the password with the numeric keypad on
41. than the atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction The precautions given in this manual are concerned with this product GT10 or between a PC GT Designer2 Ver 2 77F or later and GT10 LDR 3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the In this manual the safety precautions are ranked as DANGER and CAUTION machinery within the premisse i ifs Category II applies to equipment for which electrical power is supplied from fixed facilities Indicates that incorrect handling may cause hazardous The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous 4 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation conditions resulting in medium or slight personal injury or physical damage GT1020 GT1030 2 2 Performance Specifications 2 3 Communication Specifications Item Specifications Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow
42. the GOT power aerospace medicine or passenger movement vehicles consult with f f Mitsubishi Electric Orange amp OS installation screen is not active e This product has been manufactured under strict quality control However Green Install the data after the OS installation screen is displayed on the when installing the product where major accidents or losses could occur if the GOT product fails install appropriate backup or failsafe functions in the system afa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN