1. or from an outside phone Refer to the Phone Menu on page 5 for available options House Phone Press three times The system disconnects the outside phone line and asks you for a passcode Outside Phone 1 Call the premises phone number 2 Ifthe call is answered by either a person or a telephone answering device press three times to disconnect the answering party and access the system 3 Enter your passcode when prompted If the phone is not answered by a person or telephone answering device the system answers after a programmed number of rings Enable Installer Access Master User only My system supports this feature Use this option to grant system access to an alarm company representative From the Control Center Enter the Master User passcode and wait until the system times out control center display stops flashing If using the Master User token present the token several times until the system announces Turning the system off From the Phone Menu 1 From the Phone Menu press 3 to select System Maintenance 2 Press 3 to select System Test Menu 3 Press 6 to enable installer access Disable Installer Access To disable installer access to the system turn the system on Using the Key Fob Key Fob Button Configuration Optional Your alarm company representative must complete the table below Select only one option for each button Button Assignments Butto
2. Easy Series User s Guide EN Intrusion Control Panel Easy Series User s Guide Using the Control Center Using the Control Center Display States ff The system is off No alarm or trouble A conditions exist You can turn the system on Ze if jh The system is on occupied Nas ON ied Turning the System On or Off occupie Select an option from the table below to turn your system on gt ON unoccupied or off Exit Delay in progress system on occupied or Wait for the icon on the control center to turn red and for unoccupied Exit Delay to start before you leave the building Option Description Present token Follow control center instructions The control center announces the time remaining at designated intervals Circle segments turn on one at a time to provide a visual status of Exit Delay status During the last 10 sec it sounds a quick beep before the system turns on You have _60 _ sec to exit the building before an alarm occurs Entry Delay system on occupied or unoccupied Enter passcode Follow control center instructions The control center sounds a quick beep during Entry Delay Circle segments turn off one ata time to provide a visual status of Entry Delay status An alarm occurs if you do not turn the system off in the designated time Amber display First half of Entry Delay Invalid Passcode Entry Limit Red display Second half of Entry D
3. e warning of danger e Install smoke detectors in all locations as identified by local code or law Smoke detectors on each level Smoke detectors in or near sleeping areas e Practice an escape plan Because there might be very little time between detection of a fire and the time it becomes deadly every family member must understand how to quickly evacuate according to the plan e Have a primary and alternate escape route Because stairwells and hallways could be blocked during a fire exiting through a bedroom window must be part of the escape plan If the sleeping area is above the ground floor install a means of safely descending outside the building if one does not already exist e Arrange to meet at a location away from the house such as a neighbor s house so you know that everyone is accounted for e Ifthe alarm was accidentally sounded silence the bell reset the detectors and immediately notify your alarm company that there is no emergency situation EN50131 Compliance EN50131 1 Security Grade 2 Environmental Class II Logical Key Number of Unique Combinations Six digit Passcode 15 625 42 000 000 000 Key Fob 2 800 000 000 000 000 Only Numbers 1 to 5 are allowed For technical support please contact 2006 Bosch Security Systems Inc FO1U025111B as Recyclable BOSCH
4. elay You have _ 20 _ sec to turn the system off before an alarm occurs com X There is a system problem Follow all control Nt center instructions One or more points are faulted Follow all control center instructions Press lt to turn the system on unoccupied Press to turn the system off Refer to Key Fob Button Configuration on page 4 for more key fob options 9 You have _ _ attempts to correctly enter a passcode before the system locks out the control center for _3__ minutes Your alarm company representative sets these values Too many faulted points ef lt e Control center test Icons alternately flash Sa 7 2 AS OS The control center sounds a quick double beep five min before the end of the test Your alarm company sets these time entries 2 Bosch Security Systems Inc 8 06 FO1U025111B Easy Series User s Guide Using the Control Center Refer to page 5 for a complete list of User Menu options User Authority Turn the system on or off 1 Start a two way voice session 1 Access the System Maintenance Menu Change own passcode Access the User Menu Refer to the Phone Menu on page 5 for more information Only the Master User can access the full User Menu Users 2 to 21 can change only their own passcode Refer to the Emergency Buttons Phone Menu on page 5 for more information Your alarm company must activate these buttons in the Chime Mode
5. n w ee BOO PO a __ EO oOo ooo o o o E E Seres OOO ewr SOS riwitslss SSS Bws lt P OSS Easy Series User s Guide Silencing an Alarm Silencing an Alarm If an alarm occurs the system waits 30 sec before sending the alarm report to the central station Your alarm company can adjust the delay time To abort the alarm during this delay time present your token enter your passcode or press gt on the key fob The alarm is silenced You have sec to abort an alarm User Passcode and Point Descriptions User Passcodes User 0 Installer If an alarm occurs and the system sends the Alarm report when the delay time ends present your token enter your passcode or press I on the key fob to send an Alarm Cancel report The alarm is silenced You have min to send an Alarm Cancel report Your alarm company sets these time entries Alarm and Trouble Events Your system can send up to alarm or trouble events until you turn off the system or reset it Your alarm company sets this value a User __ Passcode Description Pi Masted o n2 D A A Ee ti S Oa a C EB S S e o T ee S G Points Point 0 on board tamper switch input ro CO a Bosch Security Systems Inc 8 06 FO1U025111B Easy Series User s Guide System Information System Information Phone Line Seizure Your security system includes a telephone line seizure feature Your alarm company can p
6. n Options System Status Default Turn System On Occupied Turn System On Custom Turn Output On or Off Turn Output On for Two Seconds Silent Panic Operation C My system sends a Silent Key Fob Panic report Key Fob LED Status Description A key fob button was pressed The LED either stops flashing or one of the other status indicators in this table occurs Red fast flash The system is in alarm or silent panic feature was used Red slow flash Exit delay in progress system occupied or unoccupied Red on steady The system is on occupied or unoccupied An error occurs while turning the system on The system does not turn on as expected Alternating red and green Green fast flash The system is not ready to turn on A button programmed for system status also shows this status Green slow flash The system is off and is ready to turn on The button programmed for system status also shows this status Either O or O was pressed to turn an output on continuously or turn it on for two seconds Either i or O was pressed to turn an output off Green on steady Red on steady and slow green flash Green on steady and slow red flash Bosch Security Systems Inc 8 06 F01U025111B Easy Series User s Guide Phone Menu Phone Menu Before you can access the Phone Menu you must start a phone session Refer to page 4 for instructions Turn system on and stay inside Turn system
7. ne on which they are located Smoke detectors might not be able to warn in time about fires started by explosions improper storage of flammables overloaded electrical circuits or other types of hazardous conditions e If phone lines are out of service reports from the security system to the central station cannot be sent Phone lines are vulnerable to compromise by several means e Inadequate maintenance and failure to test are the most common causes of alarm failure To ensure that all system components work correctly test your system regularly and have it inspected according to local code or law Although having a security system can make you eligible for reduced insurance premiums the system is no substitute for insurance Warning devices cannot compensate you for loss of life or property Bosch Security Systems Inc 8 06 FO1U025111B Fire Safety and Evacuation Residential fire is a leading cause of accidental death Most fire related deaths occur at night when occupants suffocate in their sleep from smoke and toxic gases rather than from burns To help reduce this risk use the following guidelines e Minimize fire hazards Smoking in bed cleaning with flammable liquids such as gasoline leaving children home alone and using unsafe holiday decorations are some of the common causes of household fire e Install a fire alarm system The primary purpose of this system is to alert people by giving the earliest possibl
8. on and leave a Turn on custom protection E Turn System On or Off Only use this option on non UL systems Exit Two Way Voice Session Enter user passcode Users 1 to 21 Ea iS Set date and time ic Full system test Phone Menu i System test menu System Maintenance Ed Event history Reset system a Exit Add new user Change user User Menu Delete user Exit Me les Only the Master User can access the full User Menu Users 2 to 21 can only change their own passcode Operate Outputs To turn an output on or off press the corresponding number key on the phone Exit End phone session Bosch Security Systems Inc 8 06 FO1U025111B Listen to person at control center End voice session To add or change a user To hear this option custom protection must be enabled Talk to person at control center The voice session only lasts 90 seconds To reset the timer press 1 on the phone during talk mode or 2 during listen mode Warning device test Battery test Communication test Control center test Point test Operate outputs OR Expert Programming Enable Installer Access Refer to Enable Installer Access on page 4 for more Exit system test menu information Most recent events Events by date Last alarm event Last 10 events Exit Change token Record description Change passcode Change key fob Exit Output Descriptio
9. rogram your system to send reports over the phone line to the central station You cannot use your phone when the system is sending reports to the central station If the central station cannot receive reports your phone service might be unavailable for up to 20 minutes as the system tries to contact the central station If your phone service is interrupted your security system cannot send reports to the central station unless it has another way of sending them Limitations Not even the most advanced security system can guarantee coverage against burglary fire or environmental threats All security systems are subject to possible compromise or failure to warn for a variety of reasons including but not limited to the following e Ifsirens or horns are placed outside the hearing range of people in remote areas of the building or in areas that are frequently closed they do not provide the intended protection e If intruders gain access through unprotected points of entry the system cannot detect their entrance e If intruders have the technical means of bypassing or disconnecting all or part of the system they cannot be detected e Ifthe AC power supply is off and the standby battery is either missing or dead detectors cannot detect intrusion e Smoke detectors cannot detect smoke in chimneys walls or roofs or smoke blocked by a closed door They cannot detect smoke or fire on a level of the building different from the o
10. system before you can use them Press and hold the appropriate emergency button for two sec If Chime Mode is on the control center sounds a tone to start an alarm whenever a perimeter point is faulted and the system is off Button s to Alarm To turn Chime Mode on or off Enabled Hold Cadence ar ee Hr Ae Panic Steady Hold 2 sec ON OFF To adjust the volume of the control center Key Fob met me ST vee A Adding or Changing Users Tokens and Key CE gt be gt X Fobs Hold 2 sec LOW MEDIUM HIGH QUIET m m Quiet Control Center Exit Delay and Entry Delay tones are silenced pala eee tADD CHANGE oexere Audio Interface Speak into this area to talk to someone on the telephone This system supports up to 22 users during a two way voice session e User 1 Master user Default passcode is 1234 55 e Users 2 to 21 System users e User 22 Duress user The system sends a Duress report when the Duress user s passcode is used to turn the system off You cannot assign a token or key fob to the Duress user Your alarm company must enable the Duress user The length for all passcodes can be four or six digits depending on system programming Follow all control center instructions Bosch Security Systems Inc 8 06 FO1U025111B 3 Easy Series User s Guide Starting a Phone Session Starting a Phone Session You can perform several functions with your security system from the house phone