Home
Zipato Micro Module Motor Controller User Manual v1.4
Contents
1. Group1 which support MULTILEVEL_SWITCH_REPORT METER_ REPORT_COMMAND_V3 ALARM_REPORT 6 1 REPORT THE SHUTTER POSITION Every time when user presses S1 or S2 and let shutter to move Micromodule will report the position status to controller and after every 10 movement Micromodule will send Multilevel Switch Report to Group 1 as well Multilevel Switch Report Ex Report position at 30 Command Class Multilevel Switch Multilevel Switch Report Value 30 6 2 METER COMMAND CLASS The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current 1 5 load power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller When the power consumption of load vary over 5 it will send Meter report to the nodes of Group as well 6 2 1 INSTANT POWER CONSUMPTION WATT OF SWITCH When receiving Meter Get Command it will report Meter Report Command to the requested node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 OxEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 6 2 2 ACCUMULATED POWER CONSUMPTION KW
2. everything under control MICROMODULE MOTOR CONTROLLER QUICK ra suki GUIDE v1 TRADEMARKS Zipato and the Zipato logo are registered Trademarks All other product names mentioned herein may be trademarks or registered trademarks of their respective companies NOTICE Although Zipato has attempted to ensure the accuracy of the content of this manual it is possible that this document may contain technical inaccuracies typographical or other errors Zipato assumes no liability for any error in this publication and for damages whether direct indirect incidental and consequential or otherwise that may result from such error including but not limited to loss of data or profits Zipato provides this publication as is without warranty of any kind either express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose The published information in the manual is subject to change without notice Zipato reserves the right to make changes in the product design layout and driver revisions without notification to its users This version of the Installation guide supersedes all previous versions ELECTROMAGNETIC COMPATIBILITY When operated according to manufacturer instructions the product complies with all applicable CE harmonised standards from EMC Directive 2004 108 EC and Part 15 of the FCC Rules The connections conducting HF signals must not be damage
3. EC EN 300 220 1 V2 4 1 EN 300 220 2 V2 4 1 EMC 2004 108 EC EN 301 489 1 V1 9 2 EN 301 489 3 V1 6 1 LVD 2006 95 EC EN 60669 2 1 2004 A1 2009 A12 2010 used in conjunction with EN 60669 1 1999 A1 2002 A2 2008 Changes or modifications not expressly approved by Tri plus grupa d o o for compliance could void the user s authority to operate the equipment KE THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE Changes or modifications not expressly approved by Zipato for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the
4. H When receiving Meter Get Command it will report Meter Report Command to the requested node Meter Get Command Command Class Meter Meter Get Scale 0x00 Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x00 Size 4 Meter Value KWh Example Scale 0x00 KWh Precision 2 Size 4 Bytes KW h Meter Value 1 0x00 KWh Meter Value 2 0x01 KWh Meter Value 3 0x38 KWh Meter Value 4 0xA3 KWh Accumulated power consumption KW h Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KW h 6 2 3 AC LOAD VOLTAGE V When receiving Meter Get Command it will report Meter Report Command to the requested node www zipato com 02 Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x04 Size 2 Meter Valuev Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 6 2 4 AC LOAD CURRENT 1 When receiving Meter Get Command it will report Meter Report Command to the requested node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01
5. consumer The Limited Product Warranty set forth below is given by Tri plus grupa d o o Europe herein referred to as ZIPATO This Limited Product Warranty is only effective upon presentation of the proof www zipato com 03 of purchase Upon further request by ZIPATO this warranty card has to be presented too EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY ZIPATO MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ZIPATO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD TO THE EXTENT ALLOWED BY LOCAL LAW THE REMEDIES IN THIS WARRANTY STATEMENT ARE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AGAINST ZIPATO THEY DO NOT HOWEVER AFFECT OR RESTRICT THE RIGHTS YOU HAVE AGAINST THE BUSINESS YOU BOUGHT A ZIPATO PRODUCT FROM IN NO EVENT WILL ZIPATO BE LIABLE FOR LOSS OF DATA OR FOR INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL INCLUDING LOST PROFIT OR DATA OR OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE HOWEVER NOTHING IN THIS AGREEMENT LIMITS ZIPATO S LIABILITY TO YOU I IN THE EVENT OF DEATH OR PERSONAL INJURY TO THE EXTENT RESULTING FROM ZIPATO S NEGLIGENCE OR II TO THE EXTENT RESULTING FROM ANY FRAUDULENT MISREPRESENTATION ON THE PART OF ZIPATO OR III TO THE EXTENT ARISING UNDER P
6. is applied LED repeatedly flashes in 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion AUTO INCLUSION The function of auto inclusion will be executed as long as the Micromodule does not have Node ID and is connected to main power Note Auto inclusion timeout lasts 2 minutes during which the node information of explorer frame will be emitted once every several seconds Unlike inclusion function as shown in the table below auto inclusion doesn t require pressing on off buttons on the Micromodule The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z Wave Certificated Primary Controller to access the Setup function and to include exclude associate devices Function Description LED Indication The Z Wave Controller does No node ID not allocate a node ID to the Micromodule 2 second on 2 second off Put your Z Wave controller into inclusion mode by following the instructions provided by the menei controller manufacturer AE one as Pressing Include button three times within 2 seconds will enter inclusion mode Put the Z Wave Controller in exclusion mode One press one Pressing Include button three flash Exclusion times within 2 seconds will enter exclusion mode second on Node ID has been excluded second off Sr 5 gt Pressing Include button three times within 2 seconds will enter inclusi
7. using Z Wave command class user can set a threshold current to get the warning caused by abnormal operation Micromodule have overload protection function and can help to prevent short circuit caused by load make your home smart APPLICATION In Wall Switch 2 relay 1A and 1C Type al iE en COM Relay 1A type CHOOSING A SUITABLE LOCATION Do not locate the Micromodule facing direct sunlight humid or dusty place The suitable ambient temperature is 0 C 40 C Do not locate the Micromodule where there are any combustible substances or sources of heat e g fires radiators boiler etc After putting it into use the body of Micromodule may become little hot on touch which is normal operation MOVING RANGE CALIBRATION It is important to carry out a shutter calibration process before putting controller to use with your shutters Press and hold inclusion button for more than 3 seconds and release before the th second after which Micromodule will start shutter calibration process The process is composed of three consecutive stages The shutter moves to the TOP in first stage and to the BOTTOM in second stage and to the TOP again in third stage After calibration procedure Micromodule will correctly memorize full range of UP and DOWN shutter movement During the shutter calibration process if any emergency happens you can press and release the include button to stop the process If shutter movement direction is
8. ART 1 OF THE CONSUMER PROTECTION ACT 1987 OF THE UNITED KINGDOM SOME STATES OR COUNTRIES DO NOT ALLOW 1 A DISCLAIMER OF IMPLIED WARRANTIES 2 A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR 3 LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS IN SUCH STATES OR COUNTRIES SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY YOU ARE ADVISED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS This Limited Product Warranty applies to ZIPATO branded hardware products collectively referred to as ZIPATO Hardware Products sold by ZIPATO Europe its European subsidiaries affiliates authorized resellers or country distributors collectively referred to as ZIPATO Resellers with this Limited Product Warranty The term ZIPATO Hardware Product is limited to the hardware components and all its internal components including firmware The term ZIPATO Hardware Product DOES NOT include any software applications or programs GEOGRAPHICAL SCOPE OF THE LIMITED PRODUCT WARRANTY This Limited Product Warranty is applicable to Hardware Products sold by Zipato Resellers in all countries listed at the beginning of this document under the heading Countries in which this ZIPATO Lim
9. H_START_ LEVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_ CHANGE or SCENE_ACTIVATION_SET Micromodule won t do any movement change but report alarm to Group that indicate the S1 or S2 not been released When Micromodule detects a overload power it will report alarm to Group1 make your home smart Command_Class_ Alarm Alarm_Report Alarm Type 0x08 Alarm Level OxFF Overload Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0x00 Normal When in Two Push Button switch type S1 or S2 are closed and not released to open and Micromodule receive any control moving command from Z Wave RF it will report alarm to Group1 Command_Class_ Alarm Alarm_Report Alarm Type 0x01 Alarm Level OxFF S1 or S2 close to L Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0x00 S1 and S2 released from L 7 Z WAVE S CONFIGURATION Configuration Parameter 1 Watt Meter Report period 2 0x01 0x7FFF 5 720s 3600s 1 oS 720 hour KWH Meter Report 2 Denied 0x01 Ox7FFF 6 10min 1 hour Threshold of current for Load Caution 2 10 500 Threshold of KWH for Load Caution External switch type 1 1 2 2 1 One Push button 2 Two Push button Configuration Parameter 6 Level report mode 1 1 2 1 Report destination 2 level in 5s 2 Report 10 percent level while running 7 1 WATT METER REPORT PERIOD www Zzipato com If the setti
10. Precision 2 Scale 0x05 Size 2 Meter Valuelll Example Scale 0x05 I Precision 2 Size 2 2 Bytes of Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 6 2 5 LOAD POWER FACTOR PF When receiving Meter Get Command it will report Meter Report Command to the requested node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 6 2 6 Reset Accumulated Power Consumption KWh This command is to reset the Accumulated Power Consumption KWh to 0 Meter Reset Command Meter Reset Command Command Class Meter Meter Reset 6 3 ALARM REPORT COMMAND When Micromodule detects Overload it will send Alarm_Report to Group1 Alarm Type 0x08 Alarm Level 0xFF When receive Alarm_Get command and the Micromodule is not in overload status it will send Alarm_Report Alarm Type 0x08 Alarm Level 0x00 6 3 1 ALARM REPORT When in Two Push Button switch type S1 or S2 close to L and not been release and Micromodule receive some control moving command from Z Wave RF Ex BASIC_SET BINARY_SWITCH_ SET MULTILEVEL_SWITCH_SET MULTILEVEL_SWITC
11. SS_ BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ALARM COMMAND_CLASS_METER_V3 COMMAND_CLASS_SCENE_ACTIVATION COMMAND_CLASS_SCENE_ACTUATOR_CONF COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 TROUBLESHOOTING Micromodule is not working and LED is turned off Cause of Failure Micromodule is not connected to the Main power Micromodule is broken Recommendation Check power connections Don t open up the Micromodule and send it for repair The shutter move direction is reverse Cause of Failure Wrong connection of NC and NO to the motor Recommendation Swap the NC NO connection Micromodule LED light work fine but can not control Cause of Failure No association setting Same frequency interference S1 or S2 are pressed in Two Push Button switch type Micromodule would not accept RF command Recommendation Carry out association Wait for a while to re try Release S1 and S2 Having trouble installing your new product Zipato s website contains the latest user documentation and software updates for Zipato products and services www zipato com You can also find answers in the Zipato Community at community zipato com Zipato Support supportfazipato com LIMITED PRODUCT WARRANTY GENERAL TERMS Nothing in this Limited Product Warranty affects your statutory rights as a
12. UCT WARRANTY If a product defect occurs ZIPATO s sole obligation shall be to repair or replace any defective Zipato Hardware Product free of charge provided it is returned to an Authorized ZIPATO Service Centre during the Limited Warranty Period Such repair or replacement will be rendered by ZIPATO at an Authorized ZIPATO Service Centre All component parts or hardware products that are replaced under this Limited Product Warranty become the property of ZIPATO The replacement part or product takes on the remaining Limited Warranty Period of the replaced part or product The replacement product need not be new or of an identical make model or part ZIPATO may in its discretion replace the defective product or any part thereof with any reconditioned equivalent or superior product in all material respects to the defective product PRODUCT TYPE WARRANTOR Tri plus grupa d o o Banjavciceva 11 10 000 Zagreb CROATIA TEL 385 0 1 4004 404 FAX 385 0 1 4004 405 DECLARATION OF CONFORMITY d The manufacturer Tri plus grupa d o o declares under our sole responsibility that the product Marketing model Micromodule Motor Controller Regulatory model ph pan08 Trade Brand name Zipato www zipato com is in conformity with the Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC R amp TTE Directive 1995 5 EC and carries the CE marking accordingly The following harmonized standards were applied R amp TTE 1995 5
13. When receives Multilevel Switch Stop Level change Command Micromodule will stop the motor 4 SCENE ACTIVATION COMMAND CLASS 4 1 SCENE ACTIVATION SET COMMAND When Micromodule receives Scene Activation Set command it will read the level of the pre configured Scene ID from EEPROM And it will be controlled as a Multilevel Switch Set command The Dimming Duration of the command will be ignored because Micromodule can not control the speed of motor 5 SCENE ACTUATOR CONFIGURATION COMMAND CLASS 5 1 SCENE ACTUATOR CONFIGURATION SET COMMAND Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 0 Level 0 99 or 255 The current setting of MM Motor Controller will not be override Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 1 Level 0 99 or 255 The Level value in this Command is associated to the Scene ID make your home smart 5 2 SCENE ACTUATOR CONFIGURATION GET COMMAND Command Class Scene Actuator Configuration Scene Actuator Configuration Get Scene ID 1 255 Command Class Scene Actuator Configuration Scene Actuator Configuration Report Scene ID 1 255 Level 0 99 or 255 Dimming Duration 0 OxFE Report the Pre configured Scene ID of MM Motor Controller 6 Z WAVE S GROUPS INTRODUCTION ASSOCIATION COMMAND CLASS VERSION 2 There is only one group called Group1 there is only one node for
14. cept Basic Set Command which value is either 0x00 Bottom or Top 0x63 0xFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 0xFE is not acceptable Command Class Basic Basic Set Value 0x63 or OxFF control the shutter to the top OxFF Command Class Basic Basic Set Value 0x00 0 control the shutter to the bottom 0x00 Command Class Basic Basic Set Value 0x01 0x62 control the shutter to the position between bottom and top 2 BINARY SWITCH COMMAND CLASS 2 1 BINARY_SWITCH_GET When Micromodule receives Binary Switch Get Command it will send Binary Switch Report Command to report the position of the shutter When the report value is 0x00 that means the Shutter is bottom down if the report value is OxFF that mean the Shutter is at the top But if report value is OxFE that means the position is unknown Binary Switch Get Command Command Class Binary Switch Binary Switch Get Binary Switch Report Command Command Class Binary Switch Binary Switch Report Value 0x00 BOTTOM Command Class Binary Switch Binary Switch Report Value OxFE UNKNOWN Command Class Binary Switch Binary Switch Report Value OxFF TOr 2 2 BINARY_SWITCH_SET Micromodule can only accept Binary Switch Set Command which value is either 0x00 Bottom or Top OxFF other value is not acceptable Command Class Binary Switch Binary Switch Set Value OxFF 255 control the shutter to the to
15. ch Report Command Command Class Multilevel Switch Multilevel Switch Report Value 0x00 BOTTOM Command Class Multilevel Switch Multilevel Switch Report Value 0x01 0x62 Between BOTTOM and TOP Command Class Multilevel Switch Multilevel Switch Report Value 0x63 0xFF TOP 3 3 MULTILEVEL SWITCH START LEVEL CHANGE This is the command which is used to move the shutter up to the top or down to the bottom Command Class Multilevel Switch Multilevel Switch Start Level Change Up Down Value 3 3 1 UP DOWN BIT If Up Down Bit 0x00 Shutter move up If Up Down Bit 0x01 Shutter move down If Up Down Bit 0x03 no move Command Class Multilevel Switch Multilevel Switch Start oe Up Down 0x00 control the shutter to the top OxFF Command Class Multilevel Switch Multilevel Switch Start Level Change Up Down 0x01 control the shutter to the bottom 0x00 Command Class Multilevel Switch Multilevel Switch Start Level Change Up Down 0x03 Don t move the shutter or stop the moving shutter ATT Ignore_Start_Level Start_Level Dimming Duration Inc Dec Step_size can not be used Micromodule can not control the speed of motor It may have some distance error caused by motor start up time If user founds the error become significant you may use S1 or S2 to move the shutter to the end or remotely move shutter to 0 and 100 which will automatically calibrate this error 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE
16. d or altered in any way by the user TAKE CARE OF YOUR SAFETY Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required DANGER RISK OF ELECTROCUTION All work on the device should only be carried out by trained and skilled electricians Observe the country specific regulations DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT The device has no basic insulation and must therefore be installed in a way that protects against accidental contact DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT When installing a wall plate the distance between the cover s fixing brackets or screws and the connections of the flush mounted MicroModule Motor Controller must be at least 4 mm once installed If the distance is less than 4 mm a deeper installation box must be used The fixing brackets or screws of the cover must not press against the housing Only insulated tools may be used for operation on the device e g an insulated phase tester CAUTION The connected devices and the flush mounted receiver can become damaged if devices are operated that do not correspond to the technical specifications see technical data make your home smart INTRODUCTION Using Micromodule Motor Controlle
17. el operation and higher data rates 9 6 40 100kbps Overload protection Auto reports wattage when variation exceeds 5 Very low power power consumption Over the air firmware update Easy installation SPECIFICATION TECHNICAL SPECIFICATION PROTOCOL Z Wave Plus OPERATING VOLTAGE 100 240VAC MAXIMUM LOAD 5A Resistive load OPERATING TEMPERATURE 0 C 40 C RANGE Minimum 30m indoor 70m outdoor WEIGHT 39g DIMENSIONS 46mm x 15mm x 39mm PACKAGE WEIGHT 68g PACKAGE DIMENSIONS 67mm x 22mm x 162mm REGULATIONS EMC 2004 108 EC R amp TTE 1995 5 EC LVD 2006 95 EC FCC PART 15 WARRANTY 1 year MODELS AND FREQUENCIES EUROPEAN UNION EU version UNITED STATES US version RUSSIA RU version ISRAEL IS version AUSTRALIA AU version INDIA IN version ph pan08 eu 868 42 MHz ph pan08 us 908 42MHz ph pan08 ru 869 02MHz ph pan08 is 916 02MHz ph pan08 au 921 42MHz ph pan08 in 865 20MHz INSTALLATION AND OPERATION Put the in wall Micromodule into a wall box and connect the AC power wire L N to Micromodule connector L N Connect the wall switch to the Micromodule as shown in picture To manually roll the shutter blinds up or down simply press the external switch S1 or S2 The detail is described in Z Wave configuration section External switch type of this manual Micromodule built in meter function can read the Watt KWh V Voltage I Current PF Power Factor of the load by
18. equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet ona circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DISPOSING AND RECYCLING YOUR PRODUCT When it reaches end of life dispose of the product according to your local enviromental laws guidelines and regulations H This symbol on the product or packaging means that according to local laws and regulations needs to be disposed of separately from household waste Once this product has reached the end of its life please take it to a collection point recycle facilites designated by your local authorities some will accept your product for free or simply drop it off at your Zipato re seller store By recycling the product and its packaging in this manner you help to conserve the environment and protect human health At Zipato we understand and are committed to reducing any impact our operations and products may have on the environment To minimize this impact Zipato designs and builds its products to be as environmentally friendly as possible by using recyclable low toxic materials in both products andpackaging make your home smart COPYRIGHT 2015 Tri plus grupa d o o All Rights Reser
19. ile the shutter is moving In this switch type the inclusion exclusion reset association function can also be fulfilled by pressing S1 just like the operation of include button When S1 is short pressed the shutter will move up toward TOP OxFF If during this movement S1 is short pressed again the shutter will stop moving A third short pressing of S1 will move the shutter down toward BOTTOM 0x00 If during this movement S1 is short pressed again the shutter will stop moving And so on Inverting direction and stopping 7 5 2 TWO PUSH BUTTON THE DEFAULT SETTING IS TWO PUSH BUTTON 2 If this setting is configured as Two Push Button S1 and S2 input will be valid but will not accept pressing S1 and S2 at the same time In this switch type the inclusion exclusion reset association function can also be fulfilled by pressing S1 or S2 just like the operation of include button When S1 is pressed and held more than 1 5 seconds the shutter will move up toward TOP OxFF and the shutter will stop moving when S1 is released When S2 is pressed and held for more than 1 5 seconds the shutter will move down toward BOTTOM 0x00 and the shutter will stop moving when S2 is released When S1 is short pressed the shutter will move up toward TOP OxFF If during this movement S1 i short pressed again S1 again the shutter just keep moving up toward TOP OxFF The easy way to stop this moving is short pressing S2 When S2 is short pressed the shutte
20. ited Product Warranty applies The Limited Product Warranty will be honored in any country where ZIPATO or its authorized service providers offer warranty service subject to the terms and conditions set forth in this Limited Product Warranty However warranty service availability and response times may vary from country to country and may also be subject to registration requirements LIMITATION OF PRODUCT WARRANTY ZIPATO warrants that the products described below under normal use are free from material defects in materials and workmanship during the Limited Product Warranty Period set forth below Limited Product Warranty Period if the product is used and serviced in accordance with the user manual and other documentation provided to the purchaser at the time of purchase or as amended from time to time ZIPATO does not warrant that the products will operate uninterrupted or error free or that all deficiencies errors defects or non conformities will be corrected This warranty shall not apply to problems resulting from a unauthorized alterations or attachments b negligence abuse or misuse including failure to operate the product in accordance with specifications or interface requirements c improper make your home smart handling d failure of goods or services not obtained from ZIPATO or not subject to a then effective ZIPATO warranty or maintenance agreement e improper use or storage or f fire wate
21. ng is configured for 1hour set value 720 the Micromodule will report its instant power consumption every 1 hour to the node of corresponding Group The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr Default value is 1 hour 7 2 KWH METER REPORT PERIOD If the setting is configured for 1hour set value 6 the Micromodule will report its Accumulated Power Consumption KW h every 1 hour to the node of corresponding Group The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days Default value 1 hour 7 3 THRESHOLD OF CURRENT FOR LOAD CAUTION This is a warning when the wattage of load exceeds the preset threshold value If the setting value is 500 when the load current over this value Micromodule will send current meter report command to the node of corresponding Group Default value 500 7 4 THRESHOLD OF KWH FOR LOAD CAUTION This is a warning when the KWh of load over the preset threshold value If the setting value is 10000 when the Accumulated Power Consumption of Relay1 or Relay2 over this value Micromodule will send KWh Meter Report command to the node of corresponding Group minimum value is 1KWh and default value is 10000 kWh 7 5 EXTERNAL SWITCH TYPE 7 5 1 ONE PUSH BUTTON When the configuration setting is One Push Button only S1 input will be valid The control moving commands can be accepted in this switch type wh
22. on mode One press one RESA Within 1 second press Include flash button again for 5 seconds until LED is off 0 5 second on IDs are excluded Oececcondiott Have Z Wave Controller entered in association mode ear OR One press one psec hae Pressing Include button three flash times within 2 seconds will enter association mode There is 1 group Group 1 for the Micromodule Including a node ID allocated by Z Wave Controller means inclusion Excluding a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller PROGRAMMING 1 BASIC COMMAND CLASS The Micromodule will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET When Micromodule receives Basic Get Command it will send Basic Report Command to report the position of the shutter When the make your home smart report value is 0x00 that mean the shutter is at the Bottom if the report value is 0x63 or OxFF that mean the shutter is at the Top any other value between 0x01 0x62 imply shutter is at the position between top and bottom Basic Get Command Command Class Basic Basic Get Basic Report Command Command Class Basic Basic Report Value 0x00 BOTTOM Command Class Basic Basic Report Value 0x01 0x62 Between BOTTOM and TOP eae Class Basic Basic Report Value 0x63 0xFF TOP 1 2 BASIC_SET Micromodule can ac
23. p OxFF But if the shutter is on the way down this command will stop the shutter Command Class Binary Switch Binary Switch Set Value 0x00 0 control the shutter to the bottom 0x00 But if the shutter is on the way up this command will stop the shutter 3 MULTILEVEL SWITCH COMMAND CLASS VERSION 3 3 1 MULTILEVEL SWITCH SET Micromodule can accept Multilevel Switch Set Command which value is either 0x00 Bottom or Top 0x63 or OxFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 OxFE is not acceptable Command Class Multilevel Switch Multilevel Switch Set Value 0x63 or OxFF 255 control the shutter to the top OxFF Command Class Multilevel Switch Multilevel Switch Set Value 0x00 0 control the shutter to the bottom 0x00 Command Class Multilevel Switch Multilevel Switch Set Value 0x01 0x62 control the shutter to the position between Bottom and Top 3 2 MULTILEVEL SWITCH GET When Micromodule receives Multilevel Switch Get Command it will www zipato com send Multilevel Switch Report Command to report the position of the shutter When the report value is 0x00 that mean the shutter is at the Bottom if the report value is 0x63 or OxFF that means the shutter is at the top any other value between 0x01 0x62 imply shutter is at the position between top and bottom Switch Multilevel Get Command Command Class Multilevel Switch Multilevel Switch Get Multilevel Swit
24. r acts of God or other catastrophic events This warranty shall also not apply to any particular product if any ZIPATO serial number has been removed or defaced in any way ZIPATO IS NOT RESPONSIBLE FOR DAMAGE THAT OCCURS AS A RESULT OF YOUR FAILURE TO FOLLOW THE INSTRUCTIONS FOR THE ZIPATO HARDWARE PRODUCT LIMITED PRODUCT WARRANTY PERIOD The Limited Product Warranty Period starts on the date of purchase from ZIPATO Your dated sales or delivery receipt showing the date of purchase of the product is your proof of the purchase date You may be required to provide proof of purchase as a condition of receiving warranty service You are entitled to warranty service according to the terms and conditions of this document if a repair to your ZIPATO branded hardware is required within the Limited Product Warranty Period Other than in respect of products for domestic use in particular those listed in the first and last boxes in the table below this Limited Product Warranty extends only to the original end user purchaser of this ZIPATO Hardware Product and is not transferable to anyone who obtains ownership of the ZIPATO Hardware Product from the original end user purchaser PRODUCT WARRANTY PERIOD TABLE Micromodule Motor Controller PRODUCT WARRANTY E PERIOD y IMPORTANT The content of Product Type listed above is subject to change please refer to the www zipato com for latest update PERFORMANCE OF THE LIMITED PROD
25. r user can control connected roller shutters and blinds finely adjust their position with his Z Wave controller Z Wave remote or simple push of a button Micromodule Motor Controller is Z Wave Plus enabled device which makes it compatible with any Z Wave enabled network regardless of the manufacturer Slim design makes it easy to fit in majority of wall boxes New smart relay calibration technology reduces inrush current caused by the load and enables module to work perfectly with all kinds of roller shutters and blinds Micromodule is able to detect position of the Shutter by using the patterned power measuring method so it can be remote controlled not only fully up or down but also can be adjusted to ex 30 or 50 When manually operated by the push button Micromodule Motor Controller can also memorize the position and send the new shutter position to its controller ex IP Gateway OVERVIEW FIGURE 1 Dimensions unit mm love P as INCLUDE_BUTTON PACKAGE CONTENT 1PC Micromodule Motor Controller 1PC Quick Installation Guide www zipato com FEATURES Slim compact remote Z Wave module switches and controls all parametres of power that your electrical appliances consume Precise feedback about roller position Max load up to 1100W Zero crossing switch Higher output power enhances communication rangel 2 5dBm output power compared to 2 5dBm 300 series New Z Wave 500 series chip supports multichann
26. r will move down toward BOTTON 0x00 WIf during this movement S2 is short pressed again S2 again the shutter just keep moving down toward BOTTON 0x00 The easy way to stop this moving is short pressing S1 When in Two Push Button switch type S1 or S2 are pressed and not released and PANO8 receive any control moving command from Z Wave RF Ex BASIC_SET BINARY_SWITCH_SET MULTILEVEL_ SWITCH_SET MULTILEVEL_SWITCH_START_LEVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE or SCENE_ ACTIVATION_SET PANO8 won t do any change in position but report alarm to Group Alarm_Type 1 Alarm_level 0xFF this indicate that the S1 or S2 not been release ATT To avoid misunderstanding that RF command does not work it is recommended to check the status of S1 and S2 7 6 LEVEL REPORT MODE Mode 1 In 5 seconds period after controlled by a moving command make your home smart it will report the destination level when received request command Out of the 5 seconds period it will report the actual level of the shutter when received request command Mode 2 Whenever the shutter moves past a 10 percent level it will auto report the level to Group 1 node Z WAVE COMMAND CLASSES COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SWITCH_BINARY COMMAND_CLA
27. reversed this may be caused by the wrong connection of NC and NO to the motor please change NC and NO connection and execute calibration process again For safe issue please select the motor which can stop by itself when going to bottom end or top end LED INDICATION State Type LED Indication Regardless of up and down position or open closed status Led will flash every second during Motor Motor activate state When S1 or S2 close to L activate the LED will flash even when the motor stop by itself this is to let user know the S1 or S2 are still closed and not being released yet Under normal operation when the Micromodule has not been allocated a node ID the LED flashes No node ID on and off alternately at 2 second intervals By pressing S1 S2 or Include button it will stop flashing temporarily When Micromodule is in learning mode LED Learning flashes on and off alternately and repeatedly at 0 5 second intervals When overload state occurs the Micromodule is disabled and LED flashes on and off alternately at 0 2 second intervals Micromodule will send alarm_type 8 alarm_Level 0xFF to Group1 Overload state can be cleared by disconnecting and reconnecting the Micromodule to the main power Overload www zipato com 01 ADDING TO Z WAVE NETWORK In the front casing there is an include button with LED indicator below which is used to carry out inclusion exclusion reset or association When first power
28. ved No part of this manual may be reproduced or transmitted in any form without the expressed written permission of Tri plus grupa d o o www zipato com 04
Download Pdf Manuals
Related Search
Related Contents
Texte intégral PDF Macchina avvolgitrice serie SP Istruzioni イモビバイパスアダプター (IBA-01) BenQ DC E510 User`s Manual - Downloaded from ManualsCamera APC Rack Mounting Bracket for NetBotz Camera Pod 160 Manual de usuario de la Cámara UVD-IP-XP3DNR(-P) LevelOne FCS-3000 webcam Orbiter Manual Formatting Used in This Manual Copyright © All rights reserved.
Failed to retrieve file