1. A B Configuration of DLK645 with front cover off is on Figure A Physical configuration of DLK645 is on Figure B Contacts assignment Contact Function 12V For power supply wiring GND Ground RXD Reader s white wire connection TXD Reader s green wire connection RTE RTE button connection DC Door contact connection NC Normally closed relay contact NO Normally open relay contact COM Common relay contact BEL Bell connection open darin ARM Restricted access mode open drain 6 Integrated Technical Vision Ltd http www itvsystems com ua The Control Panel Operation The Control Panel Operation To operate and program the panel you need only one reader power supply and electric lock It is also desirable to equip a door with door contact and RTE button The DLK645 control panel can operate in one of several modes Main mode Restricted Access mode and Free Pass mode For installation and programming details see Installation and Programming chapters accordingly If the panel is installed and programmed successfully DLK645 receives data sent to it from the remote reader decides whether access should be granted or not and then unlocks the door or not All enrolled ID cards codes are granted access in the Main mode And in Restricted Access mode only ID cards codes with necessary access level are granted access Main Mode Operation Blinking red LED of the reader indicates that the control pane
2. chapter Inputs and Outputs Six inputs for power supply reader RTE button and door contact connection are provided on board the DLK645 control panel Three relay contacts outputs normally closed normally open and common are supplied Output for bell connection open drain and output for Restricted Access Mode open drain are supplied Operating modes The DLK645 access control panel can operate in one of the following operating modes Main Mode Restricted Access Mode and Free Pass Mode In Main mode the panel grants access to all enrolled cards codes In Restricted Access mode access is granted to ID cards with Advanced Access level and on RTE button pressing Advanced Access level is set during programming For programming details see Programming chapter In Free Pass mode the panel unlocks the door for everybody to pass freely e g during fire alarm General Specifications One relay Supply voltage 12 2V Operational temperature 0 55 C Relative humidity 80 without moisture condensation Physical dimensions 64 5 x 64 5 x 11 Weight 60 gram Power consumption 12V 20mA Switchable current on NC NO COM 5A 28V direct current BELL and ARM outputs assume connecting of loading up to 15 V and up to 30mA http www itvsystems com ua Integrated Technical Vision Ltd 5 General configuration General configuration 12V GNDRXD TXD RTE GND DL NC NO COM BELARM
3. intruder alarm system The output is an open drain It is closed to GND when the panel is switching to the Restricted GND Access mode and remains closed until the control of external of external panel switches to the main mode system system http www itvsystems com ua Integrated Technical Vision Ltd 11 Quick Start Quick Start If Restricted Access mode is not required and default settings see further of the control panel agree with the requirements of your access control system follow the procedure of the quick start The DLK645 control panel can start operating in the Main mode once the master card master code is programmed and users cards codes are enrolled Therefore all you need to operate the panel is to program the master card master code and enroll several users cards codes To program the master card master code proceed as follows 1 Short jumper PGM on the panel s baseplate 2 Energize the control panel The LED of the reader starts to blink yellow 3 Pass a card enter a code which will be used as the master card master code hereafter to the reader Alternately blinking red yellow and green LED indicates that the master card master code is successfully programmed Code of the master card is recorded in zero memory register 4 De energize the panel 5 Take off the jumper PGM 6 Energize the control panel To add a new card code proceed as follows 1 Pass the master card master code to the rea
4. purporting to act on its behalf to modify or to change this warranty nor to assume for it any warranty or liability concern ing this product In no event shall ITV Ltd be liable for any direct indirect or consequential damages Loss of anticipated profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product http www itvsystems com ua Integrated Technical Vision Ltd 3 Contents Design Change Disclaimer ccccceceeeeeeeeeeeceeeeeeeeeeeeaeeeeeeeeenaeeeeeeeeeaas 2 Reproduction Disclaimer nnn 2 Trademarks ELI RIA LIRE Lig 2 Training and technical support n 2 Complete Delivery ni ene 2 Limited Waranty eseas ia aAA e aaah 3 General Description 5 General Specifications eet 5 General Configuration iisi rali nata lager Rate dannata rana 6 The Control Panel Operation rennene 7 Installation terrai ae 9 Mounting iia nia he richie laicale iano 9 WING iaia RL Asili nia 10 Quick Statt maree aa 12 Programming Atrani a ots sateusianitde Ri ili iii e 13 Programming the master card code 13 Shifting menu items of the programming Mode 13 Adding New Cards i eieae iota aiani Ia e arr 14 Deleting Cards eneidiaa rn 14 Setting door time rio ila nsoh a Hea ao 15 Setting lock timMe lt c iui e 15 Sett
5. Access mode switching If door remains open after the end of door time then bell activates for the pro grammed time Blinking yellow red LED of the reader indicates that the control panel is in the Re stricted Access mode Output of the Restricted Access mode is closed to GND On presentation of a card with programmed attribute of Restricted Access mode switching or RTE button pressing the control panel grants access and switches the Restricted mode OFF The unit switches the Restricted mode ON when a door is closed or door time is up Restricted Access mode output is broken when the door is open and closed when the door is closed or door time expired If no card is programmed the necessary attribute the Restricted Access mode cannot be switched on http www itvsystems com ua Integrated Technical Vision Ltd 7 The Control Panel Operation Switching off the Restricted Access mode To switch the Restricted Access mode OFF pass a card with programmed attribute of Restricted Access mode switching to the reader The control panel switches to the Main mode and grants access to registered cards If door remains closed after card presentation to the reader then control panel stays in the Restricted Access mode when door time expires Beeping buzzer and blinking red LED of the reader indicate that error is detected during switching the Restricted Access mode ON Free Pass Mode Operation Sometimes situations arise when a door should be open
6. DLK645 Access Control Panel Installation Manual DLK645 ACCESS CONTROL PANEL This manual covers installation programming and utilization of DLK645 access control panel Read this manual carefully prior to installing and programming the unit Design Change Disclaimer Information due to design changes and product improvements in this manual is the subject to change without notice ITV reserves the right to change the product design any time that will subsequently affect the contents of this manual ITV assumes no responsibility for any mistakes that can appear in the manual The company guarantees that this Installation Manual is up to date and corresponds with the unit you purchase Reproduction Disclaimer All rights to this document are preserved by ITV Ltd Copying printing and any other kind of unauthorized reproduction of this document or a part of it is prohibited Trademarks ITV is a registered trademark of ITV Ltd Training and technical support ITV Ltd provides training in installation programming and utilization of DLK645 access control panel For detailed information about the training and discussing of our particular requirements to the unit please contact our personnel It is recommended for the staff intended for sales and installation of DLK645 access control panel to take instruction courses conducted by ITV company Technical support assumes the calls of trained specialists End users must apply to t
7. an ID card used as a door key Codes of cards are recorded and stored in memory cells of the panel Proximity cards may be in shape of plastic cards keytrinkets etc Two access levels access in the Main mode and access in Restricted Access mode can be programmed for cards with the DLK645 control panel Master card code Master card code is used to switch the panel to different menu items of the program ming mode Any ID card code may be registered as master card code Master card code is used for programming only it cannot be used to access through an access point Refer also to Programming chapter Reader Readers are devices assigned for reading information from cards and transmitting it to control panel DLK645 can control one access point using an external reader The control panel is compatible with readers produced by ITV Ltd which have RS interface RTE Request to Exit button To exit from the premises a button wired to the control panel is used This button is called RTE Request To Exit button If someone opens a door otherwise than pressing RTE button by reenergizing locking device opening lock with a key etc bell acti vates for the programmed time RTE button may be used for remote door opening as well RTE button pressing grants access both in the Main and Restricted Access modes Door Contact DC In access control systems various sensors can supervise door status opened or closed magnetic door sensor sen
8. cessary menu item To do this pass master card to the reader or press on reader keyboard five times consecutively Steady lighting yellow LED indicates that the panel is in Programming Advanced Access Level menu item of programming 3 Pass an enrolled user card to the reader or enter user code Steady red LED indicates that the card code has no additional attributes Steady green LED in con trast means a card code has an attribute of Restricted Access mode switching 4 Pass the card to the reader or enter user code Steady green LED indicates that the card is programmed the attribute of Restricted Access mode switching To shift to the Main mode pass the master card to the reader or press on reader keyboard consecutively four 4 times To shift to the next item of programming menu pass the master card to the reader or press on reader keyboard once The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds Programming the attribute of Free Pass mode switching Any user can be programmed the attribute of Free Pass mode switching which provides the ability to switch ON the Free Pass mode To set the attribute of Free Pass mode switching to a card follow this procedure 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Shift to the necessary menu item To do this pass mast
9. der Buzzer beeps five times indicating that the panel is in the programming mode 2 Blinking green LED indicates that the panel is in Adding New Cards Codes menu item of programming Pass a card code to the reader Beeping buzzer indicates the user number that is number of memory register where the card code is added for example long beep pause long beep pause one short beep indicate the 001 user number Confirm code entering by pressing key One long beep means that the card is already enrolled in the unit Two long beeps mean that the unit memory is overloaded all memory registers are occupied 3 To add more cards codes return to step 2 Now the panel is ready for the operation with the following factory defaults Door time 10 seconds Lock time 5 second Bell time 0 seconds Lock type Maglock To exit the programming mode and switch to the Main mode pass the master card master code to the reader seven 7 times consecutively Otherwise switch OFF and then switch ON the power supply of the DLK645 control panel The control panel switches to the main mode automatically when no card is passed to the reader or no key pressed within 40 seconds 12 Integrated Technical Vision Ltd http www itvsystems com ua Programming Programming Programming chapter describes how to enroll delete users cards and program some parameters for the DLK645 panel to work properly Master card switches the unit to program
10. ds Deleting Cards To delete a card from the DLK645 control panel s memory you must know the user number A card may be deleted using another card preceding it in the list of enrolled cards Therefore it is recommended to list all cards indicating users numbers and names To delete a card code follow the steps below 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Shift to Deleting Cards item of programming menu To do this pass master card to the reader or press on reader keyboard once more Blinking red yellow LED indicates that the panel is in Deleting Cards menu item of programming 3 Pass a card previous to a card you wish to delete to the reader For example pass a card with register number 010 to delete a card with register number 011 Buzzer beeps the user number of the deleted card To delete a code enter the code or its memory register and press 4 To delete more cards codes return to step 2 14 Integrated Technical Vision Ltd http www itvsystems com ua Programming The list of registered cards is circular that is to delete the first card in the list use the last one If there is only one user in the list pass this only card to the reader to delete it To shift to the Main mode pass the master card to the reader or press on reader keyboard consecutively eight 8 times To shift to the next it
11. e master card are deleted from the control panel s memory To shift to the Main mode pass the master card to the reader or press on reader keyboard one time The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds Hardware reset to factory defaults Hardware reset to factory defaults erases everything from the DLK645 control panel except the list of cards and the master card code and restores the default setting This procedure may be useful if the panel experienced programming problems or you wish to delete earlier programming To reset the DLK645 panel to factory defaults proceed as follows 1 Cut off the power of the access control panel 2 Join BEL and RTE contacts of the panel 3 Power on the panel 4 Wait for 15 20 seconds till buzzer beeps discretely and LED blinks red yellow and green alternately 5 Cut off the power and disjoin BEL and RTE contacts Now the panel is reset to the following factory defaults Default door time 10 seconds Default lock time 5 second Default bell time 0 seconds Default lock type Maglock Users cards codes and master card code are not deleted from the panel s memory during resetting to factory defaults 18 Integrated Technical Vision Ltd http www itvsystems com ua General Notions General Notions To avoid misunderstandings some general notions are clarified below ID card In access control systems each user has
12. em of programming menu that is Setting door time pass the master card to the reader or press on reader keyboard one time The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds Setting door time Factory default of door time is 10 seconds Door time can be set in one second increments from one 1 to thirty one 31 seconds To set door time proceed as follows 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Shift to Setting Door Time item of programming menu To do this pass master card to the reader or press on reader keyboard twice again Alternately blinking yellow green and red LED indicates that the panel is in Setting Door Time menu item of programming 3 Pass any card either enrolled or not to the reader as many times as required For example to set door time to 30 seconds pass a card successively 30 times to the reader Door time can be set using reader keyboard For example to set door time to 10 seconds enter 1 0 One second blinking red LED and beeping buzzer indicate that an error is detected during programming you presented a card to the reader more than 31 time To clear the error condition and set door time less than 31 second exit the programming mode and then return to Setting door time menu item of programming To shift to the Mai
13. emory register further called a user number is indicated with buzzer beeps A digit corre sponds to number of beeps zero is indicated as one long beep and digits are sepa rated with a pause Fill out a paper chart listing all enrolled cards codes with users names and numbers To add a new card code proceed as follows 1 Pass the master card to the reader or press button of reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Blinking green LED indicates that the panel is in Adding New Cards menu item of programming Pass a card to the reader or enter code on reader keyboard Beeping buzzer indicates the user number that is number of memory register where the card is added for example long beep pause long beep pause one short beep indicate the 001 user number One long beep means that the card code is already enrolled in the unit Two long beeps mean that the unit memory is overloaded all memory registers are occupied 3 To add more cards codes return to step 2 To shift to the Main mode pass the master card to the reader or press on reader keyboard consecutively nine 9 times To shift to the next item of programming menu that is Deleting cards pass the master card to the reader or press on reader keyboard once The control panel switches to the main mode automatically when no card is passed to the reader and no keyboard button is pressed within 40 secon
14. er card to the reader or press on reader keyboard six times consecutively Blinking red LED indicates that the panel is in Programming the attribute of Free Pass mode switching menu item 3 Pass an enrolled user card to the reader or enter user code Steady red LED indicates that the card has no additional attributes Steady green LED in contrast means a card code has an attribute of Free Pass mode switching 4 Pass the card to the reader or enter user code Steady green LED indicates that the card is programmed the attribute of Free Pass mode switching To shift to the Main mode pass the master card to the reader or press on reader keyboard consecutively three 3 times To shift to the next item of programming menu that is Programming Lock Type pass the master card to the reader or press on reader keyboard once The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds Programming Lock Type This menu item of programming allows specifying any lock as ordinary door lock or electromagnetic lock with built in sensor of open door To set type of lock follow this procedure 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Shift to the necessary menu item To do this pass master card to the reader or press on reader keyboard seven times consecutively Steady red LED
15. for free pass to everyone e g in case of fire earth quake or any other disaster For such cases the panel has Free Pass mode In this mode reader LED blinks green and yellow alternately Access point switches into Free Pass mode when a card with programmed attribute of Free Pass mode switching is passed to the reader At the appropriate card presenta tion door lock relay activates and door sensor together with RTE button are not activated While Access point is in Free Pass mode the locking device is locked and the panel does not respond to cards passing PIN entry or RTE button pressing 8 Integrated Technical Vision Ltd http www itvsystems com ua Installation Installation Installation chapter contains information concerning mounting of the control panel procedure and wiring diagrams Mounting DLK645 access control panel is to be mounted inside the premises It is recommended that the panel should be mounted in a secure place close to a controlled door or behind the false ceiling Reader is located exterior to the room to be accessed approximately at a level of door handle For reader mounting details refer to the reader manual Mounting of the panel proceeds as follows Open the housing of the panel Remove carefully the main printed circuit board Mark out two holes on a wall using back housing as a master plate Drill two holes 6 mm in diameter Set in nailing plugs Secure back hosing to the wall th
16. gh relay contacts To save contacts from damage protect them with diode connected in reverse to current supply of the coil The diode must be con opened when nected to connection terminals of lock voltage applied Note the fact that some cheap electric door strikes Electric lock are not intended for being energized for prolonged DLK645 time Program relay time as short as possible to avoid coil overheating HGA0059Q0069 Note that when type of electric lock opened at RTEGND DL NC NO COMBEL voltage applied is used door remains closed at de energizing To open a door at power loss use either locks which can be opened mechanically or locks that are locked when voltage applied When power supply without backup is used momentary unlocking of door during 10 milliseconds may take place at power loss Bell Bell output can be used to connect a siren consumption current at most 30mA to the panel or the panel to an alarm system The output is an open drain Time of bell sound duration can be programmed For to Zn programming details see Programming chapter Bell is to be connected to GND and BEL terminals of the control panel to GND To install the bell refer to the manual of this bell Electric lock locked when voltage applied Connecting Restricted access mode output Restricted access mode output is intended for integration of DLK645 control panel with other systems e g
17. heir local dealers or installers If you do not have a dealer in your area you can contact us at support itvsystems com ua Complete Delivery The following items are supplied from the factory with the primary delivery of DLK645 access control panel DLK645 access control panel reader of ITV Ltd manufacture diode 1N4007 LED L 53 ID plastic dowel screws 4 pieces user manual 2 Integrated Technical Vision Ltd http www itvsystems com ua Limited Warranty ITV Ltd warrants that for a period of eighteen months from the date of purchase the product shall be free of defect in materials and workmanship under normal use and that in fulfillment of any breach of such warranty ITV Ltd shall at its option repair or replace the defective equipment upon return of the equipment to its repair depot This warranty applies only to defects in parts and workmanship and not damaged incurred in shipping or handing or damaged due to causes beyond the control of ITV Ltd such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of ITV Ltd This warranty contains the entire warranty ITV Ltd neither assumes nor authorizes any other person
18. indicates that the panel is in Programming Lock Type menu item 3 Pass an enrolled user card to the reader or enter user code Green LED indicates that the type of lock is set to ordinary lock Yellow LED means electromagnetic lock type http www itvsystems com ua Integrated Technical Vision Ltd 17 Hardware reset to factory defaults 4 To change lock type pass the card or enter user code once more To shift to the Main mode pass the master card to the reader or press on reader keyboard consecutively two 2 times To shift to the next item of programming menu that is Erasing the panel memory pass the master card to the reader or press on reader keyboard once The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds Erasing DLK645 Memory If necessary all cards codes can be erased from the DLK645 control panel s memory The following procedure explains how to do this 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Shift to the required menu item of programming To do this pass master card to the reader or press on reader keyboard eight times consecutively Steady lighting red LED and beeping buzzer indicate that the panel is in Erasing DLK645 Memory menu item of programming 3 Pass any card or enter any user code to the reader twice All users cards and th
19. ingibellitime aarslin idea iaia lara oi 16 Programming the attribute of Restricted Access mode switching 16 Programming the attribute of Free Pass mode switching 17 Erasing DLK645 Memory 17 Hardware reset to factory defaults 0 0 ceeeeeeeeeeeeeeennnneeeeeeeeeeee 18 General NOHOMS puiriii ii ire 19 Programming reference sheet iii 20 4 Integrated Technical Vision Ltd http www itvsystems com ua General Description General Description DLK645 access control panel is designed for use in stand alone Access Control Systems The panel provides control of access for one access point The unit is to be installed indoors in a secure place not far from a supervised door For installation details see Installation chapter Remote reader connected to the panel performs all light and audible indication Tricolor LED provides for the light indication with red yellow and green colors Built in buzzer provides for the audible indication with long and short beeps DLK645 is compatible with all proximity type cards The unit can accommodate up to 256 ID cards or keyboard codes Code must be from 4 up to 10 digits long No PC or hardware programmer is required to program the unit All programming of DLK645 access control panel is executed using master card master code and any other card either registered or unregistered or keyboard For programming details see Programming
20. l is in the Main mode When enrolled ID card code is passed to the reader the LED lights steady green relay activates for programmed lock time or till door is locked and door opens for the programmed door time or till door is closed Relay stays activated for lock time or less in case of door contact break Door contact is not inquired during lock time if electromagnetic locks with built in sensor of open door are used This option is set in programming mode in Lock type programming menu item A user will not forget to shut the door since reader s buzzer starts to beep five seconds before the end of door time Buzzer will not beep if door time is less than 3 seconds When unregistered ID card is passed or invalid code entered to the reader the panel denies access and indicates an error with short about a second blinking red LED and beeping buzzer Bell sounds for a programmed time in case that door time is up but the door is still open or that the door is opened without ID card presentation or RTE button pressing Restricted Access Mode Operation Switching ON the Restricted Access mode To switch the Restricted Access mode press RTE button for five seconds Releasing of RTE button starts door time counting Reader s buzzer beeps Opened and then closed door both actions within door time switches the Restricted Access mode ON Restricted Access mode cannot be switched on if no user is programmed the attribute of Restricted
21. ming mode and shifts it from one menu item of programming to another The master card programming is described below To set the control panel parameters such as door time lock time etc any card either enrolled or not can be used Programming the master card code To place the DLK645 control panel to programming mode you must first program the master card The master card is used for programming only To program the master card proceed as follows 1 Short jumper PGM on the panel s baseplate 2 Energize the control panel The LED of the reader lights steady yellow 3 Pass a card which will be used as the master card hereafter to the reader or enter code on reader keyboard Alternately blinking red yellow and green LED indicates that the master card is successfully programmed Code of the master card or master code is recorded in zero memory register If a registered card is passed to the reader error signal will sound 4 De energize the panel 5 Take off the jumper PGM 6 Energize the control panel Shifting menu items of the programming mode The first step in programming the DLK645 control panel is to place it into programming mode Pass the master card to the reader You can verify that the unit switched to the programming mode from the main mode as buzzer beeps five times The master card passed consecutively to the reader or reader keyboard button pressing changes menu items of the programming mode in the following
22. n mode pass the master card to the reader or press on reader keyboard seven 7 times consecutively To shift to the next item of programming menu that is Setting lock time pass the master card to the reader or press on reader keyboard one time The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds Setting lock time Factory default of lock time is 1 second Lock time can be set in one second incre ments from two tenth 0 2 to thirty one 31 seconds To set the lock time proceed as follows 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Shift to setting Lock Time menu item of programming To do this pass master card to the reader or press on reader keyboard three times more Blinking yellow green LED indicates that the panel is in Setting Lock Time menu item of programming 3 Pass any card either registered or unregistered to the reader as many times as necessary For example to set lock time to 5 seconds pass a card successively 6 times to the reader lock time will be set to 5 seconds http www itvsystems com ua Integrated Technical Vision Ltd 15 Programming Lock time can be set using reader keyboard For example to set lock time to 5 seconds enter 5 One second blinking red LED and beeping buzzer indicate that an error is detected d
23. or unregistered to the reader as many times as necessary For example to set bell time to 10 seconds pass a card successively 10 times to the reader Bell time can be set using reader keyboard For example to set bell time to 7 seconds enter 7 One second blinking red LED and beeping buzzer indicate that an error is detected during programming you presented a card to the reader more than 31 time To shift to the Main mode pass the Master card to the reader or press on reader keyboard five 5 times consecutively To shift to the next item of programming menu that is Programming the attribute of restricted access mode pass the master card to the reader or press on reader keyboard one time The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds Programming the attribute of Restricted Access mode switching A user can be programmed the attribute of Restricted Access mode switching which gives that user the privilege to access through the secured door in both Main and Restricted Access mode and provides the ability to switch OFF the Restricted Access mode To set this attribute to a card follow this procedure 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 16 Integrated Technical Vision Ltd http www itvsystems com ua Programming 2 Shift to the ne
24. rough the two holes as shown on figure below with the two ITV Systems provided screws Place the main printed circuit board into the control panel housing Connect up wires Replace the top cover and secure it with the two residuary screws Fixing back housing Fixing top cover PCB AI mounting props Top cover off Top cover on http www itvsystems com ua Integrated Technical Vision Ltd 9 Wiring Wiring Power Supply Power supply energizes the control panel It is recommended to use PSU 1 5 power supply with battery backup manufactured by ITV Ltd This power supply provides 12V power rated at 1 5A 12V and GND terminals are supplied for supply voltage wiring Operating voltage range is 10 8V through 15V Voltage capability is 16 V Reader The control panel is delivered together with remote reader of ITV Ltd manufacture which is specially programmed to work with the unit 5 Readers of other vendors cannot be used 6066 to work with the DLK645 control panel 12V GNDRXD TXD RT Terminals 12V GND RXD and TXD are used for reader connection as shown on Figure to the right Reader is to be mounted on a wall next toa door at a level of door lock For installation and programming details refer to reader s user manual Door contact The DLK 645 control panel can be wired to control the status of the door To avoid situations of several users passing through the door at a time or door remaining open after user acces
25. s 6 Programming the attribute of Restricted Access mode switching Om I Crt SPO ES SOUL IEC Ey 1OF O 7 Programming the attribute of Free Pass mode switching o AI Log HO RED CRIS SO IVO XD x On o 8 Programming Lock Type o AG aud O XD CRI 2 SO XO xD ND ALI RO 9 Erasing DLK645 memory OW COOOL OO OOO HSH A DT TITO ml All users cards and master card are deleted 100105
26. s door contact supervising the door status is provided Reader DLK645 S900 gt Door After a valid access sensor of the door connected to contact een DL and GND terminals of the DLK645 control panel wiring locks the door immediately behind the user It is recommended to provide a controlled door with a door closer RTE button The DLK 645 control panel can be wired to monitor a remote device which is intended to open the con trolled door from the interior side of the supervised DLK645 room The RTE button can be mounted on the safe side of the door or at a receptionist s desk The control panel responds to RTE button breaking with a contact RTE button requires no programming simply connect it to terminals GND and RTE of the control panel RTE button Bell output activates if deblocking button on the wining electric lock is used instead of RTE button pressing RXDTXDRTE GND 10 Integrated Technical Vision Ltd http www itvsystems com ua Wiring Electric lock The panel can control most types of locking devices thanks to availability of normally closed and normally 920898086 open relay contacts and possibility of programming ESRI NOC lock time within wide range of values 0 2 through 31 second Electric lock is to be connected to terminals NO or NC and COM of the control panel Commutation of inductive load electric lock for instance causes high energy electric impulse induced throu
27. sequence Blinking green LED indicates the panel is in Adding New Cards menu item of pro gramming Blinking red yellow LED indicates that the panel is in Deleting Cards menu item of programming Alternately blinking yellow green and red LED indicates that the panel is in Setting Door Time menu item of programming Blinking yellow green LED indicates that the panel is in Setting Lock Time menu item of programming Blinking yellow LED indicates that the panel is in Setting Bell Time menu item of programming Steady lighting yellow LED indicates that the panel is attribute of Restricted Access mode switching menu item of programming Blinking red LED indicates that the panel is programming the attribute of Free Pass mode switching Steady red LED indicates Lock type programming menu item http www itvsystems com ua Integrated Technical Vision Ltd 13 Programming Steady lighting red LED and steady beeping buzzer indicate that the panel is in Erasing DLK645 Memory menu item of programming Door contact must be closed before programming the access control panel Q If during programming no card is passed to the reader or no button is pressed on its keyboard within 40 seconds the DLK645 control panel switches to the main mode automatically Adding New Cards The most basic programming of DLK645 is adding new cards codes Every card has a unique code which is recorded in memory register of the control panel A m
28. sor of the turnstile rotor position inductive sensor of car passing through the road barrier etc Door Contact terminal of DLK645 access control panel connects these sensors Door time If door sensor is open corresponding access point goes into alarm Alarm is not invoked if contact is opened during Door Time interval This interval starts when access is granted and lasts for the programmed time or terminates on opening and subsequent closing of door contact http www itvsystems com ua Integrated Technical Vision Ltd 19 Programming reference sheet Programming reference sheet Use this reference sheet to facilitate memorization of programming procedures The following notation conventions are used below BOR oPeconkh long beep short beep steady red LED blinking red LED steady green LED blinking green LED steady yellow LED blinking yellow LED master card code unregistered user card enrolled user card Placing the control panel to the programming mode Oe dddoodos 1 Adding new cards da 4 2 Deleting cards da 3 Setting door time Ha seconds 4 Setting lock time Ow U to 3 seconds 5 Setting bell time Om Oo A GG 7 User number is 001 G GG MEANT Woh G Q User card 011 is deleted GO OG IATA IW 770000 Door time is set to 6 udd DA EA A E AA OOL Lock time is set E OGG DET Oe OO Aas Bell time is set to 15 second
29. uring programming you presented a card to the reader more than 31 time To clear the error condition and set lock time less than 31 second exit the programming mode and then return to Setting lock time menu item of programming To shift to the Main mode pass the master card to the reader or press on reader keyboard consecutively six 6 times To shift to the next item of programming menu that is Setting bell time pass the master card to the reader or press on reader keyboard one time The control panel switches to the main mode automatically when no card is passed to the reader within 40 seconds First presentation of a card while setting the lock time sets it to 0 2 seconds Second presentation of the card sets the lock time to 1 second The all subsequent card presentations increase the lock time by one second Setting bell time Factory default of bell time is 0 seconds Bell time can be set in one second increments from one 1 to thirty one 31 seconds To set bell time proceed as follows 1 Pass the master card to the reader or press on reader keyboard Buzzer beeps five times indicating that the panel is in the programming mode 2 Shift to Setting bell time menu item of programming To do this pass master card to the reader or press on reader keyboard four times consecutively Blinking yellow LED indicates that the panel is in Setting Bell Time menu item of programming 3 Pass any card either registered