Home
USER MANUAL
Contents
1. 8 Setting the Exit Delay Time This function allows you to activate your system while providing you with time to exit your premises without triggering the alarm system you can adjust the delay time from zero 00 to thirty 30 minutes With your system in programming status enter the number and symbol sequence below and where the question mark 2 appears enter the delay time you wish up to 30 minutes The default factory setting for delay time is one minute ED T2 E GS EB Enter minutes in two digits 00 means no delay 01 means 1 minute delay 30 means 30 minute delay 9 Setting the Entrance Delay Time This function allows you time to enter your premises when your alarm system is armed without triggering the alarm system The entrance delay time can be set from zero 00 to thirty 30 minutes With your system in programming status enter the number and symbol sequence below into your keypad In place of the question mark enter the delay time up to 30 minutes The default factory setting for delay time is one minute Enter minutes in two digits 00 means no delay 01 means 1 minutes delay 30 means 30 minutes delay 10 Siren Sounding Time This function allows you to set the length of time your siren will sound you have a range from silent alarm 00 up to thirty 30 minutes The factory default setting is three 03 minutes With your system in programming status enter the number and symbo
2. the ON OFF switch to the on position Secondly physically move the motion detector about in front of an object as the motion detector warms up you will hear a double beep sound indicating that it has been activated Each motion detector has to be individually activated using this procedure G2 GB ES ny E3 hoa c Enter the number for selected this sensor from 01 08 Trigger motion detector 6 Activating the Smoke Gas Detector For each smoke gas detector you use choose a number from 01 to 08 With your system in programming status on your keypad enter the number and symbol sequence below In the place of first question mark enter the number you have chosen for the sensor After entering the pound sign you will need to physically trigger the smoking gas detector to activate it To trigger the smoke detector depress the clear plastic button on the face of the smoking detector You will hear a double beep sound to indicate that it has been activated Each smoke and gas detector has to be individually activated using this procedure o GB ES G amp A EB ED E Trigger smoke gas detector Enter the number selected for this sensor from 01 08 7 Deactivating All Sensors door window sensor motion detector smoke and gas Detector Deactivating one sensor automatically deactivates all of your sensors To deactivate enter the sequence of numbers and symbols below into your keypad G2 GB E
3. USER MANUAL Introduction Congratulations on purchasing this excellent multifunction home office alarm security system This system has a clearly written English User Manual providing step by step instruction for set up Please note When you plug in your alarm system you will hear a beeping sound which signifies that your unit is functional and ready for setup You must first setup your telephone connection page 2 of this manual and program in a phone number to be stored section 11 of this manual Should you choose not to program in any phone number at this time the beeping will continue until you turn off the anti phone line cutting function section 12 of this manual When this is accomplished the beeping will stop and you will be ready to proceed with the installation of your alarm system STEP 1 Preparation of Sensors for Installation Motion Detectors a turn ON OFF switch to OFF position b open motion detector and install battery c maintain ON OFF switch in OFF position Window Door Sensor a separate sensor from magnetic bar b open the sensor and install battery c keep sensor and bar separate Smoking Detector Install battery Gas Detector Plug power cord into wall outlet Powering Up This keypad dialer has a security enhancing design which locates the power receptacle and on off switch in the interior opening on the back of the keypad dialer unit Turn your keypad so that you are facing the bac
4. ation with lost or copied keychain remotes With your system in programming status enter the number and symbol sequence below into your keypad In the blank space enter the number 1 The default factory setting is 0 OFF GB ES ED 0 function OFF 1 function ON 15 Record Message To record your outgoing message while in programming status press recorder and record your message for a maximum of 10 seconds G3 a c Speak your message into the keypad 16 Play Back To play back recorded message enter the sequence code below and in place of the question mark pick up the phone receiver to hear the message Listen to your message through phone receiver 17 Remote Access to Keypad Dialer You may change your dialer function settings arm disarm monitor remotely by phone The number of times the phone rings before you are connected with the Dialer System can be preset by entering the code sequence below into your keypad In place of the question mark enter the number of rings from one 01 to 12 12 Entering 00 turns off the remote access function The default factory setting is 08 GB o 0 a ED Phone ring setting two digit number from 01 to 12 18 Professional Monitoring Service Function This alarm system has a function which supports the use of professional monitoring service To activate this function with your syst
5. ch sensor Window door sensors may be assigned any number between 9 and 32 motion detectors smoke amp gas detectors any number between 1 and 9 You may not use any number twice each sensor must have its own number 4 Activating Door Window Sensors Each sensor needs to be numbered For each door window sensor choose a number from 9 to 32 With your system in programming status enter the number and symbol sequence below into your keypad dialer In the place of first question mark enter the number you have chosen for the sensor The second question mark comes after the pound_sign In place of the question mark you will need to physically trigger the door window sensor to activate it by bring the magnetic bar and the sensor together and then separating them Activation will be confirmed by a double beeping sound Each door window sensor has to be individually activated using this procedure Enter the number for Trigger selected this door window sensor from 9 sensor 32 5 Activating the Motion Detector For each motion detector you use choose a number from 01 to 08 With your system in programming status enter the number and symbol sequence below into the keypad dialer In place of first question mark enter the number you have chosen for the sensor In place of the second question mark after the pound sign you will need to physically trigger the motion detector to activate it On the motion detector switch
6. em in programming status enter the number and symbol sequence below into the keypad In place of the question mark enter the four digit CONTACT ID number To deactivate this function enter the coded sequence into the keypad and in place of the question mark enter 0000 Notice this system will support professional monitoring service which use the CONTACT ID the local number of the professional monitoring service must be enter as the first or second number only in the Stored Phone Number GB GB ED a ED professional CONTACT ID code must be 4 numbers Exit Programming Status When you have completed programming the system s functions push the button Exit on the keypad after 30 second system will automatically exit programming status Resetting Your System Functions Press 0000 to reset your system to the factory default setting The factory default password is 1234 STEP 3 Keypad Dialer Operation Arming Function all sensors active Home Arm Function all sensors active except motion detectors To ARM the alarm system press the away button and hold for 3 seconds To HOME ARM the alarm system After system is in the arm position press home button and hold for 3 seconds To DISARM the alarm system press password disarm For emergency press panic button Key fob Operation To arm system press lock button To disarm system press unlock b
7. en your phone line is cut or disconnected this function must be turn on to be operational With your system in programming status enter the number and symbol sequence below into the keypad In place of the question mark press 1 to turn on this function or 0 to turn off this function The default factory setting is 1 ON When this function is activated and the alarm system is armed line interruption is signaled by three siren blasts at ten second intervals followed by beeping at five second intervals When the alarm system is disarmed line interruption is signaled by beeping at ten second intervals 3 3 ED Es 0 means function is off 1 means function is on 13 Anti Interference Defense This function provides a warning siren alarm when the alarm system is being interfered with by a device operating on the same frequency Once turned on this function becomes active whenever the alarm system is armed To activate this function with your system in programming status enter the number and symbol sequence below into your keypad In the blank space enter the number 1 The default factory setting is 0 OFF GB G2 G2 ED 0 function OFF 1 function ON 14 Protecting Against Disarming Signals from Lost Keychain Remotes This function prevents anyone from disarm your alarm system with a lost keychain remote This function protects your premises from penetr
8. k of the unit You will see an open rectangular slot Inside this slot on the right is the power cord receptacle and the on off switch a Plug the power cord into power receptacle and then into your wall outlet b Turn keypad dialer power switch ON Power switch is located back of Keypad In open slot power receptacle is located back of Keypad In open slot Attach Siren Insert plug of your alarm siren into siren jack on keypad dialer Attaching telephone to keypad dialer a Insert your telephone line into the LINE jack of the keypad dialer b Insert the line from your telephone into the TEL jack of the keypad dialer Notice A phone line inserted into the wrong dialer phone jack may prevent the accessibility of the keypad dialer from a remote location by telephone STEP 2 Programming The System Each component of the alarm system has to be activated to become functional all activation takes place when the system is in programming status Exit Programming Status When you have completed programming the system s functions push the button Exit on the keypad after 30 second system will automatically exit programming status To place system into programming status enter the factory password numbers 1 2 3 4 and push the button program you can substitute your own password for factory password see section 1 You are now in programming status and in position to program any of
9. l sequence below into your keypad In place of the question mark enter the length of siren sounding time from zero 00 to thirty 30 minutes o ES ES ES EB Enter minutes in two digits 00 means silent alarm 01 means 1 minutes sound 30 means 30 minutes sounds 11 Programming Stored Phone Numbers To program your dialer with the phone numbers you want called when the alarm is triggered up to six numbers enter the number and symbol sequence below into your keypad In place of the question mark enter the phone number If your calling location requires a calling prefix e g New York requires you to dial 1 first enter the prefix along with your phone number If you want to change any stored phone number re enter the sequence code for that number and enter the new number you do not have to delete the old number as the system will automatically replace it with the new number Stored first phone number 3 1 phone number ED E G2 EB Stored second phone number 3 2 phone number ES ao ED ED ED Stored third phone number 3 3 phone number ES ES 0 a ED Stored fourth phone number 3 4 phone number o ES a EB Stored fifth phone number 3 5 phone number ES o ES a ED Stored sixth phone number 3 6 phone number a OG ED means enter your phone number 12 Phone Line Anti Cut Monitoring This system is programmed with an alarm function to alert you wh
10. the changes listed below Factory password 1234 Programmable Functions 1 Changing The Password Push the symbols and number sequence below substituting your own four number code in place of the question mark symbol GB 0O 00 aaea Enter your new 4 digit password 2 Activating Your Key Fob Remote With your system in programming status enter the number and symbols sequence below In place of the question mark 2 push any of the four buttons on your key fob remote You will hear two beeping sounds indicating that your remote control key fob is now activated Boga amp amp Push any button on key fob 3 Deactivating Your Key Fob Remote If you lose a key fob you need to prevent access to your home alarm system by someone with the lost remote Deactivate while in programming status by entering the number and symbol sequence below which will deactivate all key fob remotes After deactivation follow section 2 in order to reactivate your remaining key fob remotes on a new frequency o amp ED EB Activating the sensors Each individual sensor Motion detector window door sensor smoking gas detector has to be individually activated while unit is in programming status This system is unique in letting you know exactly which sensor is setting off the alarm Each sensor is programmed to have its own numerical identity To perform this you first assign atwo digit numbers to ea
11. utton To home arm system press house button For emergency press alarm button Remote Operation by Phone Dial the phone number that is connected to your alarm system and after approximately 8 rings the number of rings can be changed see section 17 Remote Access to Keypad Dialer you will hear two Beeping sounds That is the signal to enter the password This will be followed by two beeping sounds Follow the beeps by entering the number of the function you want to activate To arm system press number I To disarm system press number 2 To monitor your home press this allows 30 seconds of listening time press for an additional 30 seconds To exit press 4P What to do When The Alarm Auto Dialer call you When you receive the recorded message from your alarm system you have three options Functions press This allows you to monitor your premises for 30 seconds You can press again for an additional 30 seconds press This allows you to turn off the automatic calling system If you do not turn off The system will continue dialing all of your stored phone numbers Handing up phone System will proceed to dial the next stored numbers While the system is dialing through the stored number you can not call in to your phone