Danfoss TLX Web Server User Manual L00410494
Contents
1. 1 73 0 1 000 underexcited nd er 080 fa8 0 0 980 eT ra 2 88 0 0 980 underexcited 085 _ vo 3 188 0 0 950 underexcited F 0 90 4 0 0 1 000 underexcited aus P 5 0 0 1 000 underexcited 100 T T en 2 o R 8 a 6 0 0 1 000 underexcited 0 95 a 2 7 0 0 1 000 underexcited 090 E 0 85 8 10 0 1 000 underexcited 3 0 80 9 0 0 1 000 underexcited Illustration 6 17 PF P Setpoint Curves Power Factor To define the Q U setpoint curve select an option from the drop down menu under Reactive power Q L00410494 03_02 43 6 Setup Danfoss enter up to nine pairs of values select under excited or over excited for each Enter the values for each setpoint on the curve of plant nominal AC Reactive power Q voltage nominal power 1 92 0 45 00 EN 2 100 0 0 00 underexcited 45 3 3 104 0 0 00 underexcited F 3 4 112 0 45 00 underexcited 5 4 5 0 0 0 00 underexcited 0 T T Hunan o 2 o ai S g 6 0 0 0 00 underexcited 54 i 3 3 3 2 7 0 0 0 00 underexcited 2 27 z 8 0 0 0 00 underexcited 5 7 9 0 0 0 00 underexcited en Save Cancel Illustration 6 18 Q U Setpoint Curves Reactive Power
2. This menu is visible in plant and inverter views only The date time settings of the inverter can be changed here Time hh mm ss 11 57 41 Date dd mm YYYY 5 e 2010 TimeZone GMT 1 v Ww j ave Cancel Illustration 6 13 Date and Time L00410494 03_02 39 6 Setup Darfi Item Description Time The current time in the following format hh mm ss Be careful when changing the time settings of the inverter as changing the time affects data which are already logged Setting the time back one hour will result in the existing data logged for the last hour being overwritten Date The current date in the following format dd mm yyyy Be careful when changing the date of the inverter as a date change affects data which are already logged Timezone Time zone in which the inverter is located Note The master inverter automatically ensures identical date and time settings and adjustment to summer time throughout the network 6 5 Logging Inverter 6 5 1 6 5 2 40 Logging Interval l Inverter Configure the logging interval of the individual inverter at Inverter Setup Logging Logging intervals 1 minute e 10 minutes e 1 hour Logging interval 10 minutes v Illustration 6 14 Logging Interval Note Web portals support differing logging intervals
3. Item Unit Description Plant name The name of the plant Report date dd mm yyyy The reporting date Report period The reporting period daily weekly monthly Plant production kWh Energy of the entire plant delivered to the utility grid during the reporting period Plant revenue Euro The total revenue for the reporting period Equivalent CO2 emission kg The total CO2 saved for the reporting period Performance ratio A coloured bullet indicates the status of the system See the section Plant Group and Inverter Views for an explanation of Status Red Plant PR lt 50 or Any inverter in the network in fail safe mode or missing from the scan list no contact with the master Yellow Any inverter in the network with PR lt 70 or in Connecting or Off grid mode Green Plant PR gt 70 and all inverters with PR gt 70 and all inverters in On grid mode An irradiation sensor must be installed before the perform ance ratio can be calculated A notification is issued if an inverter has produced insufficient energy compared to the remaining inverters during the re porting period The message will contain a list of inverters producing insuffi cient energy If there are no events the following text is shown All inverters operating OK A notification is issued if one of the PV strings has produced insufficient energy compared to the remaining strings during the reporting period The
4. CO2 kg Allows the conversion of yield kWh This calculation factor for CO2 saving depends on the energy source to power generation ratio Per default it is set to 0 5 C02 kg Ask the local electricity provider for an exact value L00410494 03_02 6 Setup 31 6 Setup Danfoss 6 2 Communication Plant Inverter The communication menu contains the following sub menus see descriptions below Some of the menus are only visible in plant view whereas others are only visible in inverter view 6 2 1 RS485101 Inverter Network Subnet Address Save Cancel Illustration 6 4 RS485 Network Address Change the RS485 network address of the inverter here Ensure that each inverter in the net work has a unique address The RS485 addresses must be selected within the following range network subnet address 2 1 1 to 12 14 254 Note amp Only in very rare cases will it be necessary to change the RS485 address of the inverter as each inverter is delivered with a unique RS485 address 6 2 2 IP Setup 0l inverter The TripleLynx Pro inverter is equipped with two integrated Ethernet interfaces which connec tivity to Ethernet networks The inverter automatically configures a unique IP address An integrated DNS server enables access to the master inverter via its name or serial number For local administration of IP addresses the inverter also supports DHCP in the automatic c
5. Sweep type Sweep interval 15 minutes Illustration 6 37 PV Sweep Inverter View Setup Sweep type Sweep interval 15 minutes Illustration 6 38 PV Sweep Plant View Setup Item Unit Description Sweep type Select Off or Standard sweep Default is Off Sweep interval minutes Set desired frequency of standard PV sweep Default 15 minutes Force sweep Activate once off sweep independent of standard sweep interval The characteristic power curve of a PV string is non linear and in situations where PV panels are partly shadowed for example by a tree or a chimney the curve can have more than one local maximum power point local MPP Only one of the points is the true global maximum power point global MPP Using PV sweep the inverter locates the global MPP rather than just the local MPP The inverter then maintains production at the optimum point the global MPP L00410494 03_02 59 6 Setup 60 Illustration 6 39 Inverter Output Power W versus Voltage V Legend 1 Fully irradiated solar panels Global MPP 2 Partly shaded solar panels Local MPP 3 Partly shaded solar panels Global MPP 4 Cloudy conditions Global MPP PV sweep functionality comprises two options for scanning of the entire curve Standard sweep regular sweep at a pre programmed interval Forced sweep once off manua
6. Note amp A correctly configured SMTP server and internet connection IP and DNS server are necessa ry for receiving e mail messages from the inverter To test the SMTP settings go to Setup gt Messaging on plant view configure a recipient and press the Test Setup button Within a few minutes a test e mail will be sent from the inverter SMTP server address smtp mail com SMTP server port 25 SMTP server user name user Password 00000000 Password again 00000000 E mail sender invi myplant com User authentication IV Illustration 6 7 STMP Setup Item Description SMTP server address Outbox server this information can be requested from the Internet provider see below or LAN administrator SMTP server port Here the server port used for the e mail transfer can be changed At delivery it is configured to port 25 Ask the network administrator before changing this value User name Service provider s user name maximum of 24 characters can be en tered Password Password assigned by the Internet service provider For security rea sons every password character is displayed as an asterisk A max imum of 24 characters can be entered Retype password Retype the password E mail sender address Sender s e mail address used for authenticating the SMTP server An unknown sender address can cause e mail delivery to fail User Authentication As au
7. 0 PV production deviates more than 10 0 Log Submenu 0 General Displays the total production of the entire plant 0 Production log The total energy log for the entire plant accumulated data for the past 20 years 0 Irradiation log The irradiation log of the master inverter provided an irradiation sensor is connected 0 Grid management log Contains an entry for every time the inverter has received a power reduction telegram from an exter nal device The Web Server only displays the latest 20 events and the complete log can be viewed by exporting the log Table 8 2 Plant View Continued L00410494 03_02 Danfots 8 Appendix A Sitemap Main Menu Horizontal menu Page content 0 Setup 2 Submenu 0 Calibration 0 Sensors 0 Irradiation sensor scale mV 1000 W m2 0 Irradiation sensor temp coeff C 0 PV temp offset C 0 Ambient temp offset C 0 SO scale pulses kWh 0 Environment Here the values for CO2 emission and revenue calculation are en tered Submenu 0 Communication 0 GPRS Setup SIM pin code Internet access point User name Password Retype password Network roaming STMP Server address STMP Server port STMP Server user name Password Retype password Email Sender 0 User authentication 0 Communication channel Local network 0 Data warehouse Upload interval U
8. In the photovoltaic status menu all status information and settings related to the PV side of the inverter are displayed 4 3 1 PV Present Values 0 Inverter The voltage current and power detected on each PV input are displayed here 4 3 2 PV Maximum Values Inverter The maximum values of voltage current and power recorded on each PV input are displayed here The maximum values can be reset via Inverter view gt Setup gt Inverter details gt Reset max values 4 3 3 PV Input Energy Inverter The total daily energy produced by all three PV inputs as a sum and by each PV input individu ally are shown Note If two inputs are running in parallel configuration only one value will be shown 20 L00410494 03 02 4 3 4 4 3 5 4 4 AC Grid Inverter 4 4 1 4 4 2 4 4 3 Danfots 4 Status Isolation Resistance Inverter The isolation resistance between the earth and PV arrays is displayed in Ohm Q The isolation resistance is measured during the inverter self test at startup PV Configuration Inverter The current configuration of each PV input is shown This menu section displays the status of values related to the AC side of the inverter Present Values Inverter For each of the three phases the real time AC grid values are displayed for the current phase Item Description Voltageldl Voltage 10 min mean The
9. dynamic allocation of IP addresses DNO Distribution network operator DNS Domain Name System FF Fill Factor FTP File Transfer Protocol GPRS General Packet Radio Service GSM Global System for Mobile Communication ISP Internet Service Provider LAN Local Area Network MAC Media Access Control a unique hardware number of the inverter P P is the symbol for real power and is measured in Watts W PLA Power level adjustment Pnom Power Nominal conditions Pstc Power Standard Test Conditions PR Performance Ratio Q Q is the symbol for reactive power and is measured in reactive volt amperes VAr RCMU Residual Current Monitoring Unit ROCOF Rate Of Change Of Frequency RTC Real Time Clock S S is the symbol for apparent power and is measured in volt amperes VA SIM Subscriber Identity Module SMTP Simple Mail Transfer Protocol SW Software TLX TripleLynx System Requirements The TripleLynx Pro Web Server is operated exclusively from a web browser Internet Explorer from version 5 or Firefox from version 2 with either direct access via PC connection to the Ethernet interface of the communication board see Accessing the TripleLynx or remote access via the internet see Remote Connection For all language versions the Web Server software supports characters compatible with Uni code L00410494 03_02 Darfi 1 Introduction For plant group and inverter name only the following characters are suppo
10. 0 0 0 PV1 Array area m2 0 PV1 Array power W 0 PV2 Array area m2 0 PV2 Array power W 0 PV3 Array area m2 0 PV3 Array power W 0 Environment Here the values for CO2 emission and revenue calculation are en tered 0 Communication 0 RS485 Setup Network Subnet Address oo 0 IP Setup Configuration Automatic man 0 IP address 0 Subnet mask 0 Default gateway DNS Server 0 Remote access Change functional safety set a ng ti 0 Relay 0 Relay functionality Alarm Status Alarm timeout Test alarm 0 Relay functionality Self con sumption Power level Duration Trigger time 0 Inverter details 0 General Inverter name Group name Master mode List of follower inverters 1 Date and time Time Date 0 0 0 0 0 0 2 0 0 0 0 Stop alarm 0 0 0 0 0 0 0 1 1 1 Time zone 1 Reset max values Reset the max values of the inver ter 0 Logging 0 Logging interval 0 Logging capacity 1 Delete event log 1 Delete Production log 1 Delete Energy log 1 Delete irradiation log 0 Messaging 0 Enable disable messaging for the individual inverter 0 Security Change the current security level of the inverter 0 Setup details 0 Setup details 0 Language Country 2 10 min mean 10 min
11. Messaging Logging interval Data warehouse service GPRS communication setup Sensor calibration values Environmental settings settings for revenue and CO2 emission PV array settings Via the Web Server software these settings can be dumped to a file and saved locally on a PC Afterwards the file can be loaded to another inverter Upload and set the backup file before the inverter has commenced energy production This en sures the settings are used before being superseded 56 L00410494 03_02 Danfots 6 Setup Upload settings Browse Upload amp Set Illustration 6 32 Settings Backup amp Restore Item Description Backup Dumps the settings and the content of the production log of the particular inverter to a file where the location and file name are specified by the user Browse Press Browse to select an already saved settings file to be uploaded Upload amp Set Pressing this button results in the settings being sent to the inverter in ques tion Note Note that this is an unrecoverable action All earlier settings will be lost and cannot be re stored afterwards 6 11 3 Settings Report Inverter This feature enables generation of a report listing the current functional safety parameters This report has to be signed by the customer the service technician and approved by the DNO For further instructions on how to change the functional saf
12. Note amp A pop up warning appears when an inconsistent pair of values is entered 6 6 4 Fallback Values 1 Plant When the grid management box is selected as reference value enter fallback values Fallback values are automatically activated when communication fails between the master inverter and the grid management box e the master inverter and a follower inverter Set point type Off J save Cancel Illustration 6 19 Fallback Values Item Description Setpoint type OFF The fallback value is disabled The inverters will continue to run with the most recent configuration Constant reactive power Q The inverters will fall back to the value of reactive power Q specified in Va ue Constant power factor PF The inverters will fall back to the value of power factor PF specified in Va ue Value The fallback value for Q or PF 6 7 Messaging Plant Inverter Message types 44 L00410494 03 02 6 7 1 Danfots 6 Setup Yield Event DW upload Performance ratio PR Communication error Com Error Data overwrite e Plant status Each message type can be enabled or disabled individually All message types are disabled as default Recipient Plant To use the TripleLynx Pro messaging functionality define at least one message recipient by name and language A maximum of 10 recipients can be defined By default each rec
13. PCB Temperatures Inverter RPM of Fansl4 Inverter Power Module Temperatures 01 Inverter PCB Part and Serial Numberl01 Inverter PCB Software version inverter Operating Time Inverter Software Version Plant Upload Status Plant PV Sweepl0l Plant Inverter Plant Status Plant 5 Log Logging General Plant Inverter Deratingl Inverter Data Log 0 Inverter Production Log 0 Plant Inverter Irradiation Log l Plant Inverter Event Logl01 inverter Change Log Inverter Grid Management Log 01 Plant Inverter Reactive Powerl01 Inverter 6 Setup Calibrationl01 Plant Inverter Sensorsl01 Plant Inverter PV Array 0 Inverter Environmentl0 Plant Inverter Communication llPlant Inverter RS485 0 Inverter IP Setupl l Inverter Communication Channel l Plant GPRS Setup Plant L00410494 03 02 21 21 21 22 22 22 22 22 23 23 23 23 23 23 23 24 24 26 26 26 26 27 27 28 28 28 29 29 30 30 30 30 31 32 32 32 33 33 Darfi SMTP Setup Plant Data Warehouse Plant FTP Server Upload Remote Access 2 Inverter Relay inverter Relay Functionality Alarml01 Unverter Relay Functionality Self consumption Inverter Inverter Details 01 Inverter General 0 Inverter Date and Timeld1 Plant Inverter Logging Inverter Logging Interval Inverter Logging Capacityl llinverter Delete Logs In
14. go to Setup gt Inverter details 2 2 Operation 2 2 1 Web Server Structure The Web Server overview is structured as follows 12 L00410494 03 02 Danfoss 2 Getting Started Dashes 1My Plant x Group 1 view Status Log Setup 4 Master Overview x 5 x 6 Production graphs Daily 9 06 kW off Monthly 1 00 kWh 100 0 Yearly Performance graphs 0 0 kg Monthly 1 1 02 kWh Yearly Language Contact Logout Security level 0 Danfoss Solar Inverters x 7 Illustration 2 9 Overview 1 Plant name Displays the current plant name Click on the plant name to display the plant view Change the plant name at Setup Plant details 2 Group menu Displays groups of inverters Inverters join group 1 by default Click on a group name to display the group view and a list of inverters in the group Change the group name via Setup gt Inverter details in the inverter view 3 Group members Displays the inverter names in the group currently selected The default inverter name is based on the serial number see section Accessing the Web Server Click on an inverter name to display the inverter view Change the name of the inverter via Setup gt Inverter details in the inverter view 4 Main menu This menu corresponds to the inverter display main menu 5 Sub menu The sub menu corresponds to the main menu item currently selected All sub menu items belon
15. mean voltage V 2 ROCOF ROCOF limit Hz s 2 2 2 Time to disconnect ms 2 2 Time to disconnect ms 1 PV Configuration PV Configuration individual or par allel 1 PV 1 configuration PV 2 configuration 1 PV 3 configuration fare 1 Force inverter power up Turns on grid supply to the control board Table 8 11 Inverter View Continued L00410494 03_02 73 8 Appendix A Sitemap Danfoss Main Menu Horizontal menu Page content b 1 Service 1 Settings backup Performs a settings backup or a restore of the backed up settings 1 Settings report A settings report must be gener ated when one of the functional safety settings has been changed 1 Reset 1 Reset communication board 1 Reset control board 0 PV Sweep 0 Sweep type 0 Sweep interval 0 Force sweep Table 8 12 Inverter View Continued 1 PV3 is not displayed for inverter type rating 10 kW 2 When grid code is an MV country 3 When change functional safety settings is enabled 4 TripleLynx Pro variants only Only visible in the TripleLynx Pro version 74 L00410494 03 02 Danfoss Solar Inverters A S Ulsnaes 1 DK 6300 Graasten Denmark Tel 45 7488 1300 Fax 45 7488 1301 E mail solar inverters danfoss com www solar inverters danfoss com Danfoss can accept no responsibility for possible errors in catalogues brochures and o
16. Ask the service provider Note Changes to the logging interval impact e logging of detailed inverter data inverter logging capacity For more information refer to the section Logging Capacity Logging Ca pacity Ol Inverter This menu displays the current logging capacity of the data log of the particular inverter Inverter gt Setup gt Logging The logging capacity of the inverter depends on the current logging interval configuration With a default logging interval of 10 min the inverter can log its detailed inverter data for a maxi mum of 34 days It will then start to overwrite the old data L00410494 03 02 Danfots 6 Setup 6 5 3 Delete Logs 11 Inverter At security level 1 go to Inverter gt Setup gt Logging to delete the Event production irradia tion and data log of each individual inverter This menu is visible in inverter and group views Note Z Deleting a log is an unrecoverable action and data will be lost 6 6 Grid Management Plant This menu applies to TripleLynx Pro variants only Setup gt Grid management Set up ancillary services such as Power Level Adjustment PLA and Reactive Power in this area 6 6 1 Generallil Plant Nominal plant AC power kVA Q settle time s Control type off v Reference value ment box Illustration 6 15 General Item Description Nominal plant AC power Enter the total nominal AC power for
17. Daily production graphs 0 Monthly 0 Yearly Displays monthly and yearly per 0 Perf h Monthl 0 Performance graphs OT Meny formance graphs if a irradiation 0 Yearly sensor is installed on the master inverter 0 Status b Submenu 1 Reactive power 1 Control type 1 Set point 1 Value 0 Software version Displays the software version of the com board of the master inver ter 0 Upload status 0 Upload Status 0 Signal strength 0 GSM status 0 GSM network name 0 Failed uploads 0 Last error 0 Last upload 0 PV Sweep 0 Inverter name 0 PV1 0 Timestamp 0 Sweep status 0 Umpp 0 Impp 0 Pmpp 0 Uoc 0 Isc 0 FF Fill factor 0 PV2 0 Timestamp 0 Sweep status 0 Umpp 0 Impp 0 Pmpp 0 Uoc 0 Isc 0 FF Fill factor 0 Pv3 0 Timestamp 0 Sweep status 0 Umpp 0 Impp 0 Pmpp 0 Uoc 0 Isc 0 FF Fill factor Table 8 1 Plant View L00410494 03 02 63 8 Appendix A Sitemap 64 Darfi Main Menu Horizontal menu Page content L Submenu 0 Plant Status 0 Plant name 0 Report date 0 Report period 0 Plant production 0 Plant revenue 0 Equivalent CO2 emission 0 Performance ratio gt 70 0 Performance ratio 50 70 0 Performance ratio lt 50 0 Inverter production deviates more than 10
18. Inverter Internal temperatures of the inverter PCB s current temperature maximum temperature 1 Note Some PCB temperatures are only accessible at security level 1 or above L00410494 03 02 Danfots 4 Status 4 7 4 RPM of Fans 1 inverter The internal fan speed is displayed in RPM 4 7 5 Power Module Temperatures 01 Inverter Internal temperature of the inverter power modules current temperature maximum temperature 1 Note Some power module temperatures are only accessible at security level 1 or above 4 7 6 PCB Part and Serial Number Inverter The part and serial number of the control board as well as the power board the communication board and the aux board are displayed here 4 7 7 PCB Software version Inverter The software version of the control board communication board the functional safety process or and the display software are shown here 4 7 8 Operating Timel1 Inverter Total operating time of the power aux control and communication boards 4 8 Software Version Plant Software version of the TripleLynx Pro Web Server 4 9 Upload Status Plant The modem menu displays the current status of the GSM GPRS connection and the status of the data warehouse portal upload Item Description Upload status Current upload status Signal strength Signal strength Should preferably be betw
19. Overview 0 Plant Group Inverter The layout of the overview screen on both plant group and inverter basis is described in Chap ter 2 section Operation 3 2 Graphs Plant Group Inverter 3 2 1 18 The TLX Pro inverter can generate the following graphs on plant group or inverter basis Production graphs Daily Monthly Yearly Performance graphs PR or yield Monthly Yearly The performance graphs display PR only when irradiation is logged Note amp The duration of data displayed in the graphs depends on the logging interval see Logging For a detailed description of each graph shown on each individual level see below Plant View Click on the plant name to display the plant view In plant view the following graphs are gener ated based on data from the entire plant Production graph Interval Unit Description Daily kW Power output W m Irradiation levels when irradiation sensor is installed Data are displayed on an hourly basis Monthly kWh Energy production on a daily basis for the current month to date Yearly kWh Energy production on a monthly basis for the current year to date Performance graph with irradiation sensor installed Interval Unit Description Monthly Performance ratio for the current month to date Yearly Performance ratio for the current year to date Performance graph yield with no irradiation s
20. Plant production Wh PV plant production in report period Plant revenue Euro PV plant revenue generated in report period Equivalent CO2 emission kg PV plant equivalent CO2 emission reduction in re port period Performance ratio above 70 Individual inverter name Performance ratio for individual inverter Performance ratio between 50 and 70 Individual inverter name __ Performance ratio for individual inverter Performance ratio below 50 Individual inverter name __ Performance ratio for individual inverter Inverter production deviates more than 10 Individual inverter name Deviation for individual inverter PV production deviates more than 10 Inverter name PV input 1 Deviation for PV input 1 PV string 1 PV input 2 Deviation for PV input 2 PV string 2 PV input 3 _ Deviation for PV input 3 PV string 3 L00410494 03 02 25 5 Log Danfoss 5 Log 5 1 Logging This section explains the individual logs of the TripleLynx Pro All individual logs can be down loaded as csv file for further processing Not all logs are visible in both plant and inverter views When the internal log of the inverter is full it will overwrite the oldest data first To set up a notification when the internal logging capacity of the inverter is 60 full refer to the section Messaging Note amp In Internet Explorer Firefox and or firewall software the file download export of the lo
21. Server operating language temporarily click on Language in the page footer select the required language at logoff this language setting will return to default To change the default Web Server operating language refer to the section Setup Details 2 5 Compatibility in Networks with Other TripleLynx Pro Inverters The specific functionality related to the TripleLynx Pro inverter only works in networks consist ing of TripleLynx Pro inverters Likewise the specific functionality related to the TripleLynx Pro inverter only works in networks of TripleLynx inverters 2 6 Managing the Logged Data via the Integrated Web Server 2 6 1 Graphs The TripleLynx Pro inverter has the ability to generate graphs either based on the entire plant a particular group of inverters or based on each individual inverter The following types of graphs are available Production graphs on daily monthly and annual basis Performance graphs on monthly and annual basis For an in depth description of each graph type refer to the View section of this manual Plant Daily Production Plant Monthly Performance Ratio 64 Hos 7 5 30 44 H o2 20 4 24 boa 10 o4 r 0 0 ne sai OD ae a 2200 Opa ll ee ee a a ee r i 13 5 7 9 u B 9 2 3 572a 2 Show normalized values Illustration 2 11 Production Graph AC Power KW o p Irradiance kW m Performance ratio Illustration 2 12 Performan
22. characters can be found Current users e Useri e User2 Add new user User Password Password again ave Cancel un Illustration 6 34 Users Change the user name and password by clicking on the particular user in the list as shown in the illustration 6 12 3 Profiles 1 Plant The administrator selects which inverters groups the user in question will have access to User user B Can view the following groups All V Jinverter Group Illustration 6 35 Profiles 58 L00410494 03 02 Danfots 6 Setup Each user is referenced via the name configured in the users menu see above All groups belonging to the master inverter are automatically added to the page Note that a user will only have access to the view menu in plant group and inverter views Note User profiles are not stored in the display Therefore transfer of profiles from one inverter to another is not possible via the display 6 13 Plant Details Plant Inverter Enter the name of the plant here The plant name can consist of a maximum of 25 characters including spaces See the section Supported Characters for a list of allowed character types Plant name My Plant The master inverter of the plant is Iny 1 Save Cancel Illustration 6 36 Plant Name 6 14 PV Sweep i Plant Inverter This menu item is available for TLX Pro and TLX Pro only Standard sweep
23. inverter can send out e mail a valid GSM modem and SIM card must have been installed in the inverter or the master inverter must be connected to the internet If the master inverter is placed behind a network router the router must open SMTP port 25 Remember to configure the e mail settings in plant view Setup gt Communication gt SMTP For further details refer to the section SM7P Setup 6 7 2 Yield 1 Plant Check the Enable option to activate yield notification Select yield notification interval Daily weekly monthly or yearly Example Day yield plant name 27 04 2008 325 648 kWh Notification Enable Disable c Interval Daily v Enabled for test recipient Save Cancel Illustration 6 21 Yield 6 7 3 Event 0 Plant If the inverter fails to supply energy to the grid it will generate an event Activate event notifi cation to send out a notification containing a short event text together with an event id either via e mail or sms Note If all inverters in a large plant generate an event at the same time it is not guaranteed that the user will receive all event notifications from every single inverter Notification Enable Disable C Threshold Immediately v Enabled for test recipient Save Cance Illustration 6 22 Event Event threshold The event is sent when the threshold is reached Select a threshold Immediately 10 minutes 46 L0041049
24. locked the SIM into a mobile phone and unblock it 30 Jv Failed to set PIN code The PIN code is wrong Find the correct PIN code before resetting the inverter When the inverter is reset it will set the same PIN code again After two resets the SIM will block be cause it received 3 attempts to set wrong PIN 31 Jv Failed to set GPRS access point name Use only alpha numeric a z A Z 0 9 and dot APN APN is not valid characters for the APN 33 Jv Failed to set GPRS user name User name _ Avoid spaces in the GPRS user name is not valid 34 N Failed to set GPRS password Password is Avoid spaces in the GPRS password not valid 35 v Failed to open GPRS connection The APN user name or password might be wrong or GPRS is not enabled Obtain the GPRS configura tion from the GSM provider 36 Jv Jv Failed to open FTP connection Check that the Internet is connected Check that the FTP server address user name and password are correct 39 N v Failed to start file upload Check that the server and Internet connections are functioning correctly Check that the firewall does not block active mode FTP 40 N Failed to read uploaded file back to verify An attempt to obtain the file listing from the FTP server failed Check that the server and Internet connections are functioning correctly 41 v There is no data log to upload This is not an error All logged data has been sent and the inverter has not yet generated
25. new data 42 v vV The RTC of the master inverter is not set Set the inverter time to enable upload 43 N v The serial number of the master inverter is Check the master inverter serial number not valid 44 N The SIM PIN code is not valid A PIN code must be 4 8 characters long and consist only of digits No other characters are permitted Table 6 1 DW Upload Error Codes Performance Ratiol 1 Plant The follower inverters in the network will use the value from the irradiation sensor connected to the master inverter for their performance ratio calculation When follower inverters are installed in a different environment than the master inverter individual irradiation sensors can be con nected to them to obtain a more accurate calculation of the performance ratio Select Enable to receive notification when performance ratio falls below a limit value If the irradiation falls below 0 20 W m2 notification of performance ratio below limit will not be sent Note BS The PV array settings of the inverter must be configured before the performance ratio can be calculated For further details refer to Inverter gt Setup gt Calibration L00410494 03 02 Danfots 6 Setup Notification Enable Disable C Enabled for test recipient Performance ratio Save Cancel Illustration 6 24 Performance Ratio Ww 6 7 6 Communication Error Plant If the master inverter is unable to
26. 1 Sensors Plant Inverter Irr sensor scale Irr sensor temp coeff PV temp offset Ambient temp offset SO Scale Save Cancel Illustration 6 1 Sensors 56 0 mV 1000 W m 0 0 T 0 pulses kWh Item Unit Description Irradiation sensor scale mV 1000 w m The calibration value of the irradiation sensor The value is usually written on a label at the back of the sensor Note that this value must be entered before the inverter will recognise that there is an irradiation sensor connec ted Irradiation sensor temp co eff Calibration value for internal temperature correction of the irradiation measurement Only used for irradiation sensors with integrated temperature compensation PV temp offset C The temperature sensor may be calibrated using an off set ranging from 5 0 to 5 0 C Ambient temp offset C The temperature sensor may be calibrated using an off set ranging from 5 0 to 5 0 C SO scale pulses kWh In order to use an energy meter SO sensor the scale of the energy meter must be entered here For a description of which sensor to connect to the TripleLynx Pro refer to the TripleLynx In stallation Manual 6 1 2 PV Array Inverter The PV area and the rated PV power STC for the installation are defined here Note amp Refer to Messaging These definitions are required to calculate PV string compari
27. 4 03_02 Danfots 6 Setup 30 minutes 1 hour e 12 hours Example Event at plant name group name inverter name reports event Grid_1 since 21 01 2009 07 59 35 Note Read the inverter event checklist in the TripleLynx User Manual before calling service A table describing the different events and the corresponding event texts which the inverter can generate can also be found here 6 7 4 DW Upload Plant For e mail or sms notification of a data warehouse FTP upload failure select Enable The no tification includes an event code For more information about event codes refer to the Troubleshooting section of this manual Notification Enable Disable c Enabled for test recipient ave Cancel uw D Illustration 6 23 DW Upload L00410494 03 02 47 6 Setup 6 7 5 48 Darfi ID Description Remedy GSM LAN 0 v v No error 17 N v Uploaded file size check did not match The upload file was corrupted during upload Up Part of the file was probably lost load file again 18 N Modem did not connect to any GSM net Check that there is GSM coverage and SIM card is work activated 19 Jv SIM card did not respond to PIN query Replace SIM card SIM card is missing or defect 26 Jv SIM card requests a code not PIN code The SIM card is blocked Find the PUK code insert commonly PUK because SIM is
28. 4 7 Inverter Inverter 4 7 1 4 7 2 4 7 3 22 The status inverter content page displays the general status of the complete inverter Generall01 Inverter Note When calling Service note that the information listed on this web page is required in order to obtain assistance The general settings of the inverter are displayed here Item Description Country Installation country Language Language of inverter display and Web Server software The session lan guage of the Web Server software can also be changed via the footer Name Displays the current name of the inverter Group name Displays the name of the group to which the inverter belongs Operation mode Displays the current mode of operation of the inverter Installation date The date on which the inverter was installed Model Current model and inverter power class Serial number The serial number of the inverter Product number The product number of the inverter Software version The software version of the inverter MAC address The MAC address of the communication board These names can be changed in inverter view at Inverter view gt Setup gt Inverter details DC bus voltagel 4 Inverter The current and maximum values of the DC bus voltage are shown here The DC bus voltages have both a lower and an upper limit PCB Temperatures
29. Interval Unit Description Daily W Active power VA Apparent power VAr Reactive power W PV power Monthly kWh Energy production on a daily basis month to date Yearly kWh Energy production on a monthly basis year to date Performance graph PR with irradiation sensor installed Interval Unit Description Monthly Performance ratio in for the current month to date Yearly Performance ratio in for the current year to date Performance graph yield with no irradiation sensor installed Interval Unit Description Monthly hours Operating time for month to date Yearly hours Operating time for the year to date L00410494 03 02 19 4 Status Danfoss 4 Status 4 1 Status All values displayed in the Status are read only To change the inverter settings see the Setup section For a detailed description of the individual settings refer to the TripleLynx Reference Manual As the values are requested live from the inverter short delays may occur in retrieving data Fetch the newest inverter data by pressing the Reload button 4 2 Ambient Conditions Inverter If external sensors are connected to the inverter their current values are displayed here Ambient conditions Irradiance 120 W m PY module temp 18 C Ambient temp 11 C Irr sensor temp 15 C Refresh Illustration 4 1 Ambient Conditions 4 3 Photovoltaic Inverter
30. MAKING MODERN LIVING POSSIBLE Be ma 0 08 00 Dash Danfoss Solar Inverters Welcome to TripleLynx Pro Danfoss TLX Pro Web Server User Manual Three phase 8 10 12 5 and 15 kW SOLAR INVERTERS Danfots Contents Contents 1 Introduction 5 Introduction 5 Disclaimer 5 List of Abbreviations 6 System Requirements 6 2 Getting Started 8 Access and Initial Setup 8 Setup Wizard 8 Operation 12 Web Server Structure 12 Plant Group and Inverter Views 14 Security Levels 15 Changing the Language 16 Compatibility in Networks with Other TripleLynx Pro Inverters 16 Managing the Logged Data via the Integrated Web Server 16 Graphs 16 Export of Logged Data 17 Yield Notification and Events 17 Upload to Web Portal or FTP Server 17 3 View 18 Overview 0 Plant Group Inverter 18 Graphs Plant Group Inverter 18 Plant View 18 Group View 19 Inverter View 19 4 Status 20 Status 20 Ambient Conditions inverter 20 Photovoltaic Inverter 20 PV Present Values 0 Inverter 20 PV Maximum Values Inverter 20 PV Input Energyl01 Inverter 20 Isolation Resistance Inverter 21 PV Configuration Inverter 21 AC Grid 0 Unverter 21 Present Valuesl01 Inverter 21 L00410494 03 02 1 Contents Darfi Maximum Valuesl01 Inverter Residual Current Monitor 0 Inverter Grid Management Inverter Reactive Powerl Plant Inverterl01 Inverter General 01 Inverter DC bus voltage Inverter
31. Note If the initial and confirmation settings are different grid code selection is cancelled the wizard recommences step 5 Tf initial and confirmation settings match but are incorrect contact service Step 6 of 7 Replication To replicate the settings from steps 1 to 6 to other inverters in the same network Select inverters Click Replicate Note When the PV configuration installed PV power and PV array area of follower inverters in the network differ from that of the master do not replicate Set up the follower inverters individ ually L00410494 03_02 11 Darfi 2 Getting Started 6of7 Setup Wizard Step Replicate settings to other inverters WM All Name v Inv_1 iv Inv_2 Replicate Previous Next Illustration 2 7 Step 6 of 7 Replication Step 7 of 7 Inverter startup The inverter will start automatically when the installation sequence is complete see the TripleLynx Installation Manual and solar radiation is sufficient The startup sequence including self test takes a few minutes The inverter is now configured and ready to use Illustration 2 8 Step 7 of 7 Inverter startup To change the setup later access the inverter via the integrated web interface or the display at inverter level To change the name of the inverter go to Setup gt Inverter details To enable master mode
32. Overview Displays the main page with over all group status 0 Inverters Here a list of all inverters belong ing to this particular group togeth er with a colour bullet indicating their current status is shown 0 Production graphs 0 Daily Displays daily monthly and yearly production graphs 0 Monthly 0 Yearly 0 Performance graphs 0 Monthly Displays monthly and yearly per formance graphs provided an irra 0 Yearly diation sensor is installed on the master inverter Table 8 5 Group View L00410494 03_02 67 8 Appendix A Sitemap Danfoss 8 3 Inverter View Main Menu Horizontal menu Page content 0 View Submenu 0 Overview Displays the main page with over all inverter status information i F Displays the daily monthly and 0 Production graphs 9 Dally yearly production graphs of the 0 Monthly specific inverter 0 Yearly Displays monthly and yearly per 01 Pa Performance graphs 0 Monthly formance graphs provided an irra 0 Yearly diation sensor is installed on the master inverter or on this particu lar inverter 0 Status p Submenu 0 Ambient conditions 0 Irradiance w m 0 PV module temp C 0 Ambient temp C 0 Irr sensor temp C 0 Photovoltaic 0 PV Present values 0 PV input 1 0 Voltage V 0 Current A 0 Power W 0 PV input 2 0
33. Voltage V 0 Current A 0 Power W 0 PV input 3 0 Voltage V 0 Current A 0 Power W 0 PV Maximum values PV input 1 0 Voltage V 0 Current A 0 Power W PV input 2 0 Voltage V 0 Current A 0 Power W PV input 3 0 Voltage V 0 Current A 0 Power W 0 PV input energy 0 Total kWh 0 PV1 kWh 0 PV2 kWh 0 PV3 kWh 0 Isolation resistance 0 Resistance MQ 1 Minimum MQ 1 Maximum MQ 1 PV configuration 1 PV input 1 1 PV input 2 1 PV input 3 Table 8 6 Inverter View 68 L00410494 03 02 Darfi 8 Appendix A Sitemap Main Menu Horizontal menu Page content b Submenu 0 AC grid 0 Present values On Phase 1 L1 Phase 2 L2 Phase 3 L3 0 Voltage V 1 10 min mean V 1 L1 L2 V 0 Current A 1 DC cont of current mA 0 Frequency Hz 0 Power W 1 Apparent power S VA 1 Reactive power Q VAr 1 Maximum values of AC Phase 1 0 Voltage V 0 Current A 0 Power W Phase 2 0 Voltage V 0 Current A 0 Power W Phase 3 0 Voltage V 0 Current A 0 Power W 0 Residual current monitor 0 Current mA 1 Maximum value mA Table 8 7 Inverter View Continued L00410494 03 02 69 8 Appendix A Sitemap Danfoss Main Menu Horizontal menu Page content b Submenu 0 Grid mana
34. a percentage of the nomi nal plant power or directly in kVAr Enter the values for the setpoint curve under Q U Curve Relay Configuration 4 Plant When grid management box is selected as reference value configure the discrete inputs K1 K4 Each of the 16 combinations of the four discrete inputs corresponds to a specific plant output power level PLA and a reactive power output K1 K2 K3 K4 Reactive power gt E E Q Power factor PF Active M M VM Power level in D NW amp e 100 0 0 0 1 00 oj 6 amp Cc 0 0 0 0 1 00 amp amp Cc 30 0 0 0 1 00 og or A amp 100 0 0 0 1 00 e gi amp 60 0 0 0 1 00 o 8 100 0 0 0 1 00 o o Cc 100 0 0 0 1 00 o e amp 100 0 0 0 1 00 amp ec 100 0 0 0 1 00 oi amp e 100 0 0 0 1 00 amp ce amp oj 100 0 0 0 1 00 9 g a 100 0 0 0 1 00 e og 100 0 0 0 1 00 amp amp 100 0 0 0 1 00 e oj ce 100 0 0 0 1 00 o ko amp e 100 0 0 0 1 00 Save Cancel Illustration 6 16 Relay configuration L00410494 03 02 Danfots 6 Setup Item Description K1 K4 active Enable check or disable uncheck t
35. average voltage sampled over 10 min L1 L20 Phase to phase voltage Current l Current DC content of current The DC content of the AC grid current Frequency Frequency Power 0l The power on the current phase Apparent power S Apparent power on the phase in question Reactive power Q The reactive power on the phase in question Maximum Values Inverter The maximum voltage current and power values registered on the AC grid phase 1 2 and 3 are displayed here Reset the maximum values at Inverter view gt Setup gt Inverter details gt Reset max values Residual Current Monitor 0 Inverter The current and max current value seen by the Residual Current Monitor Unit RCMU Item Description Current Displays the rms value of residual current Maximum valuel l Displays the maximum recorded rms value of residual current 4 5 Grid Management Inverter Grid management displays the current status of power level adjustment current production and settings for frequency stabilization The grid management menu is only displayed if the functionality is enabled in the current grid code L00410494 03 02 21 4 Status Darfi 4 6 Reactive Power Plant The setpoint type and setpoint value of reactive power are displayed here for TLX Pro var iants only Item Description Setpoint type Displays the setpoint type Value Displays the value of the setpoint
36. ce Graph 16 L00410494 03 02 2 6 2 2 6 3 2 6 4 Danfoss 2 Getting Started Export of Logged Data Data logged by the TripleLynx Pro inverter can be exported or downloaded to a PC For further information refer to Log Yield Notification and Events Using the master inverter functionality the TripleLynx Pro inverter can send notifications by e mail or sms of production status warning in the event of inadequate production level inverter events Requirements for notification by e mail or sms All inverters are TripleLynx Pro inverters The master is connected to the internet or has a GSM modem installed All settings regarding e mail Setup gt Communication and GSM Setup gt Communica tion gt GPRS setup respectively are configured correctly Requirements for sms only a GSM modem is installed in the master inverter or an e mail to sms account from the ISP internet service provider is established For further information on notifications refer to Setup Messaging Upload to Web Portal or FTP Server The master inverter collects the data from all TripleLynx Pro inverters in its network The data can be uploaded to a web portal or an FTP server when the master inverter is connected to a network with internet access or e has a GSM modem installed For data upload frequency refer to Setup Communication Data Warehouse DW L00410494 03 02 17 3 View Darfi 3 1
37. communicate with one or more inverters in its network a message will be sent to the specified recipient The notification is sent when communication has failed for 60 minutes or more Notification Enable F Disable Enabled for test recipient Save Cancel Illustration 6 25 Communication Error uw oO 6 7 7 Data Overwrite 0 Plant Check Enable to activate a notification when the datalog content reaches the 60 limit of data capacity without a log upload Notification Enable Disable c Enabled for test recipient Cancel Illustration 6 26 Data Overwrite 6 7 8 Plant Status Plant Check Enable to activate a plant status e mail on a daily weekly or monthly basis The e mail contains important information about the energy production of each PV input PV string and each inverter This can help discover failures due to soiling partial failure of solar cells or a faulty inverter circuit L00410494 03_02 49 6 Setup 50 Darfi Notification Enable Disable Notification period Daily v Inverter income deviation 0 0 PY income deviation 0 0 Enabled for M test recipient Illustration 6 27 Plant Status Example In this example the recipient test receives a daily e mail with the following notifications INVERTER PRODUCTION DEVIATES MORE THAN 5 When the energy produced by an inverter within the plant deviates more than 5 compar
38. ct Logout Security level 0 Danfoss Solar Inverters Illustration 2 10 Plant View L00410494 03_02 2 3 Danfoss 2 Getting Started Item Unit View Description Plant Inverter and Group Overall plant sta Red Plant PR lt 50 or tus Any inverter in the network in fail safe mode or missing from the scan list no contact with the master Yellow Any inverter in the network with PR lt 70 or in Connecting or Off grid mode Green Plant PR 70 and all inverters with PR 70 and all inverters in On grid mode x Red Inverter PR lt 50 or inverter has an error Yellow Inverter PR between 51 and 70 or inver ter in Connecting mode Green No errors and inverter PR 70 and inverter in On grid mode 1 x Current production kW X x Real time energy production level Yield today kWh x x Cumulative yield for the day Total revenue Euro x x Cumulative revenue earned since initial startup Total CO2 saving kg Xx x Cumulative CO2 saved since initial startup Performance ratio xX x Real time performance ratio Total yield kWh x x Cumulative yield since initial startup Power limit adjust x Maximum power limit as of nominal inverter AC output ment rating Note To calculate performance ratio PR an irradiation sensor is required see Setup gt Calibra tion Security Levels Three predefined security lev
39. duration of derating due to PV power Temperature Hour Total duration of derating due to the inverter temperature Power Level Adjust Hour Total duration of derating due to Power Level Adjustment ment 0l D Frequency stabiliza Hour Total duration of derating due to frequency stabilization tion Reactive power Hour Total duration of derating due to reactive power D If enabled by the current grid code 5 4 Data Log l Inverter The TripleLynx Pro inverter logs detailed data for a total of 34 days at 10 minute logging inter vals before it starts to overwrite the data Logged data Data Unit Timestamp dd mm yy hh mm Irradiance W m 2 Ambient temperature C Module temperature go PV voltage per string V PV current per string A PV power per string W PV energy per string Wh Grid voltage per phase V Grid current per phase A Grid power per phase W Apparent power sum of phases VA Grid power total W Grid energy per phase Wh Today s energy production measured by S0 coun Wh ter DC content of grid current per phase mA Residual grid current mA Grid frequency mean of phases Hz DC bus voltages V Internal temperatures C Apparent power per phase VA Reactive power per phase Var Inverter operation mode Latest inverter event PLA present value Reactive power abs Q Reactive power cos Reactiv
40. e power mode D When sensor connected 2 When counter connected 5 5 Production Log Plant Inverter These data are logged at inverter level L00410494 03_02 27 5 Log Danfoss Daily energy production data during the past week The weekly energy production data for the past 4 weeks The monthly energy production for the past 12 months The yearly energy production for the past 20 years If inverter exchange is required data can be transferred to the new inverter Refer to the sec tion Settings Backup for further information At plant level this log displays the sum of energy production for all inverters in the network 5 6 Irradiation Log Plant Inverter When the inverter is equipped with an irradiation sensor these data are logged at inverter lev el Daily irradiation of the past week Weekly irradiation for the past 4 weeks Monthly irradiation for the past 12 months Annual irradiation for the past 20 years If inverter exchange is required data can be transferred to the new inverter Refer to the sec tion Settings Backup for further information In plant view this menu displays the irradiation log of the master inverter 5 7 Event Log Inverter The event log menu displays the 20 most recent inverter events Latest 20 events displays event ID date and time status on off for each of the most recent 20 events See the section Troubleshooting in t
41. ect By default each PV input is configured to run in auto detect mode thus minimising PV configu ration errors When selecting individual or parallel configuration ensure the configuration corre sponds to the physical wiring of the inverter For further information refer to the TripleLynx Reference Manual This setting is accessible for TripleLynx Pro variants only Note amp For PLA settings in TripleLynx Pro variants see the section Grid Management Setup gt Setup details For networks of TripleLynx Pro inverters plant power output level can be controlled via the Danfoss Grid Management Box as follows Configure the grid management box inputs at plant level Setup gt Setup details See the illustration Power Level Adjustment The grid management box sends set point values for reactive power and PLA to the master inverter For further information refer to the Danfoss Grid Management Box Manual L00410494 03 02 Danfots 6 Setup Power level adjustment Kl K2 K3 K4 Active K M M 7 Power level in 9 El eE 100 0 a A Cad e T AMAA E a A FA FE Ti cE 9 9 9 10 ce e 4 7 10 7 7 9 100 0 Illustration 6 31 Power Level Adjustment Item Description K1 K4 active Enable check or disable uncheck the individual inputs K1 K4 If the input is disabled its s
42. ed to the total average of the plant the report shows the inverter name Note that the plant must contain more than one inverter to obtain this notification PV PRODUCTION DEVIATES MORE THAN 3 When a PV string within a specific inverter deviates more than 3 compared to the average of the inputs on this inverter the e mail reports the name of inverter and PV input Note that a minimum of two individual PV inputs must be activated on the inverter to obtain this notification For example two individual inputs are adequate but two inputs in parallel are not L00410494 03_02 Danfots 6 Setup Plant name My plant Report date 30 07 2010 Report period Yesterday Plant production 421422 Wh Plant revenue 126 30 Euro Equivalent CO2 210 710 kg emission PERFORMANCE RATIO ABOVE 70 Inverter 1 89 1 Inverter 2 97 8 Inverter_3 75 3 Inverter_5 85 2 Inverter_6 89 0 Inverter_7 93 9 PERFORMANCE RATIO BETWEEN 50 AND 70 Inverter_4 67 2 PERFORMANCE RATIO BELOW 50 none INVERTER PRODUCTION DEVIATES MORE THAN 10 Inverter_4 11 2 Inverter 6 10 7 PV PRODUCTION DEVIATES MORE THAN 10 Inverter 3 PV input 1 13 4 PV input 2 6 3 PV input 3 7 1 Inverter_6 PV input 1 12 3 PV input 2 10 8 PV input 3 15 Table 6 2 Example of E mail Notification L00410494 03 02 51 6 Setup Panfot Content of E mail Notification
43. een 16 31 GSM signal strength GSM network name The network to which the modem is currently connected GSM status Displays the current GSM network status Failed uploads Number of consecutive failed uploads Last error Event ID together with timestamp time and date of the last event Refer to the GSM Manual for a further description of the event ID s Last upload Timestamp of last successful upload Table 4 1 Upload Status For further information refer to the GSM Manual L00410494 03 02 23 Darfi 4 Status 4 10 PV Sweep Plant Inverter To view the result of the most recent PV sweep performed go to Plant level Plant gt Status gt PV sweep Inverter level Inverter gt Status gt PV sweep To export the data click on Export Inverter level Item Unit Description Status PV1 PV input 1 Timestamp hh mm ss Time of most recent PV sweep Umpp V DC voltage at global MPP Impp A Current at global MPP Pmpp W Power production at global MPP FF Fill factor Pmpp Uoc Isc Uoc V Open circuit voltage at global MPP Isc A Short circuit current at global MPP Number of MPP Total of global and local MPP detected Status Confirmation of successful PV sweep PV2 PV input 2 Timestamp hh mm ss Time of most recent PV sweep Umpp V DC voltage at global MPP Impp A Current at global MPP Pmer W Power p
44. els filter user access to menus and options Security levels Level 0 End user no password is needed e Level 1 Installer service technician Level 2 Installer service technician extended When logged on to the Web Server as Admin access is at security level 0 Subsequent user ac counts created provide access to a predefined subset of menus according to user profile Define user profile at Plant gt Setup gt Web Server gt Profiles Access to levels 1 and 2 requires a service logon comprising a user ID and a password e The service logon provides direct access to a specific security level for the duration of the current day Obtain the service logon from Danfoss Enter the logon via the Web Server logon dialog e When the service task is complete log off at Setup gt Security e The Web Server automatically logs off the user after 10 minutes of inactivity Security levels are similar on the inverter display and the Web Server L00410494 03 02 15 2 Getting Started Danfoss A security level grants access to all menu items at the same level as well as all menu items of a lower security level Throughout the manual a 0 1 or 2 inserted after the menu item indicates the minimum security level required for access 2 4 Changing the Language The Web Server automatically operates in the same language as the inverter language setting The default operating language is English To change the Web
45. ensor installed Interval Unit Description Monthly hours Operating time for month to date Yearly hours Operating time for the year to date L00410494 03 02 Panfot 3 View 3 2 2 Group View Click on the group name to display the group view In group view a list of all inverters in the current group is displayed detailing overall status see Operation e real time production level total power output In group view the following graphs are generated based on data from the current group Production graph Interval Unit Description Daily kWh Energy production for the current day Monthly kWh Energy production on a daily basis for the current month to date Yearly kWh Energy production on a monthly basis for the current year to date Performance graph PR with irradiation sensor installed Interval Unit Description Monthly Performance ratio in for the current month to date Yearly Performance ratio in for the current year to date Performance graph yield with no irradiation sensor installed Interval Unit Description Monthly hours Operating time for month to date Yearly hours Operating time for the year to date 3 2 3 Inverter View Click on the inverter name to display the inverter view In inverter view the following graphs are generated based on inverter data Production graph
46. ety settings of the inverter refer to the TripleLynx Reference Manual where a description of the complete procedure is given The service related menus are described below Note that some of the menus are visible on plant level or inverter level only 6 12 Web Server Plant 6 12 1 Admin Plant Change the admin password for Web Server access here Current password New password Retype password Change Cancel Illustration 6 33 Admin Master Password For optimal security select a number letter combination consisting of at least eight characters for the password h Changing the password here automatically changes the password for each inver ter L00410494 03_02 57 6 Setup Danfoss Note In case the username or password is forgotten the current username and password can be reset via the display This is done via Setup gt Reset password on the display of the inver ter If the password is reset via the display of the master inverter the password will auto matically be reset for every inverter belonging to this master 6 12 2 Users Plant Via this menu the administrator can assign access for up to 10 different users A user can ac cess different groups of inverters or individual inverters Which inverters or groups the particu lar user will have access to is configured in the Profiles menu In the section Supported Charac ters a list of allowed
47. g ged data might be prevented by pop up blockers Refer to the program supplier for further information and options 5 2 General 0 Plant Inverter Displayed in inverter view Total energy production Total operating time Time of power down previous day Time of power up current day Displayed in plant view Total energy production for entire plant Note amp Time of power down and power up are displayed only when the inverter has been operating 5 3 Derating Inverter Derating the output power is a means of protecting the inverter against overload and potential failure The log records total duration of derating To view the distribution of the various types of derating level 1 security access is needed For more information on derating refer to the TripleLynx Reference Manual This menu is visible at inverter and group levels 26 L00410494 03 02 Danfots 5 Log Value Unit Description Off grid counter Hour Total duration of disconnection from grid Total derate coun Hour Total duration of power production limitation ter Grid voltage Hour Total duration of derating due to the grid voltage Grid current Hour Total duration of derating due to the grid current Grid power Hour Total duration of derating due to the grid power PV current 4 Hour Total duration of derating due to the PV current PV power 1 Hour Total
48. ge magnitude can be changed here Note that this is a functional safety setting This menu is only visible if remote access has been enabled see section Remote Access For more information on how to change the functional safety settings of the inverter refer to the TripleLynx Reference Manual where the procedure for changing the functional safety setting of the inverter is described in detail Voltage max 10 min mean 300 Y Time to disconnect on voltage max 10 min 200 ms Save NB You are updating inverter Cancel Illustration 6 29 10 Min Mean Item Description Voltage max 2 Upper 10 minute average voltage limit Time to disconnect 2 Time limit for inverter disconnection from grid 6 10 3 ROCOFI I Inverter ROCOF limit 5 000 Hz s Time to disconnect 2000 ms Illustration 6 30 ROCOF Enter the settings for the Rate of Change of Frequency ROCOF here For more information on ROCOF and functional safety settings refer to the TripleLynx Reference Manual This setting can only be changed if remote access has been enabled see section Remote Ac cess L00410494 03_02 53 6 Setup Darfi Item Description ROCOF limitl2 Trip setting in Hz s Time to disconnect 2 Time limit for inverter disconnection from grid 6 10 4 PV Configuration Inverter 54 Configure the individual PV inputs here Select Individual Parallel e Auto det
49. gement 0 Power level adjustment 0 Power level adjustment 0 Current production W 0 Frequency stabilization 0 Maximum power W 0 Activation frequency Hz 0 Slope 0 Deactivation frequency Hz 0 Reactive power 0 Setpoint type 0 Value 0 Inverter 0 General 0 Country 0 Language 0 Inverter name 0 Inverter group name 0 Inverter operation mode 0 Installation date 0 Inverter model 0 Inverter serial number 0 Inverter product number 0 Inverter SW version 0 MAC address 1 DC bus voltage 1 Upper V 1 Maximum upper V 1 Lower V 1 Maximum lower V 0 PCB temperatures 0 PCB 1 Aux C 1 PCB 2 Ctrl C 1 PCB 3 Pow C 0 PCB 1 Max Aux C 1 PCB 2 Max Ctrl C 1 PCB 3 Max Pow C 1 Internal conditions RPM of fans 1 Fan 1 RPM 1 Fan 2 RPM 1 Fan 3 RPM 1 Fan 4 RPM 0 Power module tempera tures 0 Power module 1 C 1 Power module 2 C 1 Power module 3 C 1 Power module 4 C 1 Power module 1 Max C 1 Power module 2 Max C 1 Power module 3 Max C 1 Power module 4 Max C 0 PCB Serial numbers Power board serial number 0 POW AUX board serial number 0 AUX Com board serial number Control board serial number 0 CTRL 0 COMM 0 PCB product numbers Power board part number 0 POW AUX board part number 0 AUX Control board
50. ging to a particular main menu item are displayed here 6 Content area The Web Server main menu and sub menus are identical to the menus in the inverter display The sub menu content displayed here corresponds to the sub menu selected Overview On some pages a horizontal menu is provided for im proved readability 7 Footer Options on the footer bar Language Opens a pop up window Click on the country flag to change the language of the Web Server to the desired language for the active session L00410494 03_02 13 2 Getting Started Panfoss Contact Opens a pop up window which displays Danfoss contact informa tion Logout Opens the log in log out dialog box Security level Displays the current security level as explained in the section Security Levels Note The content of the main menu changes depending on which view is currently selected the plant a group of inverters or an individual inverter The active view is indicated by text in red 2 2 2 Plant Group and Inverter Views 14 The overview screens for plant view group view and inverter view display the same overall status information Dasfott My Plant Group 1 View Status Log Setup My Plant Overview Production graphs e All inverters are present 2 2 Daily 17 57 kW Off Monthly 7 77 kWh 100 0 Yearly Performance graphs 0 0 kg Monthly 6 Yearly 908 69 kWh Language Conta
51. he TripleLynx Reference Manual for more information on specific events The complete event log consists of max 1000 entries which can be viewed by exporting the event log This menu is visible in inverter view only 5 8 Change Log Inverter Displays the most recent 20 entries from the change log of the inverter The change log records Changes to functional safety parameters Each logon with service password View the content of the change log by exporting the log 28 L00410494 03 02 Danfots 5 Log Note amp The change log keeps track of all modifications made to parameters accessed at security lev el 2 The log includes Parameter changed New setting Timestamp User name of user making the change View the change log at Inverter view gt Log Change Log 5 9 Grid Management Log Plant Inverter Contains a power reduction telegram received from the master inverter The Web Server only displays the latest 20 entries The complete log can be viewed by export ing the log 5 10 Reactive Power l Inverter This menu item is available for TripleLynx Pro variants only Grid codes where reactive power is enabled Displays a log of the sum of generated reactive energy Under excited Over excited L00410494 03_02 29 6 Setup Darfi 6 1 Calibration Plant Inverter Configuration of individual sensors PV arrays and environmental settings 6 1
52. he individual inputs K1 K4 If the input is disabled its state is ignored considered off Power level in PLA setting Output power reduction as percentage of the plant nominal AC power Reactive power Reactive power Q output in or kVAr Power factor Output power factor PF 6 6 3 Setpoint Curves Plant The TripleLynx Pro inverter is capable of generating reactive power on basis of predefined set point curves either Reactive power Q as a function of the grid voltage e Power factor PF as a function of the plant output power The setpoint curves are defined by values and displayed as a graphical curve Over excited energy is always displayed above the horizontal axis and under excited energy below the axis The curve ends are always horizontal meaning that the inverters will operate with the first set point 1 below that power or voltage level and with the last setpoint 9 above that power or voltage level The reference for the grid voltage is measured on the grid side of the master inverter The reference for the plant output power is calculated by the master inverter Reactive power generation will follow the specified setpoint curves when sufficient PV power is available To define the PF P setpoint curve enter up to nine pairs of values select under excited or over excited for each of Nominal plant AC power Power Factor PF
53. id inappropriate activation of self con sumption Time of day Set Trigger time to the desired time of self consumption activation in the format hh mm ss Self consumption is automatically de activated when the sun sets and the inverter disconnects from the grid 6 4 Inverter Details Inverter 6 4 1 General 0 Inverter The specific inverter settings for the TripleLynx Pro variant are defined here Selecting a master Changing the name of the inverter or the group to which it belongs If the particular inverter is a master in its network view the list of follower inverters by pressing the Show list button The inverter is delivered with default names for both inverter and group see the table below 38 L00410494 03 02 Danfots 6 Setup Inverter name inv4 Inverter group name Group 1 Inverter is master Iv Scan network Inverter is master of 4 inverter s Show list Illustration 6 12 Inverter Details Item Description Inverter name The name of the inverter At delivery this name corresponds to the serial number of the inverter A maximum of 15 characters can be entered see the section Supported Characters for a complete list of the valid characters Inverter group name In order to group the inverters of the plant into different groups a group name is needed A maximum of 15 characters can be used see the section Supported Characters for a comp
54. ipient receives all available message types from the inverter In the following sections the specific messages notifications which can be sent by the inverter are described in more detail Recipient Recipient id test recipient v Recipient alias test recipient Language English v SMS Email E Time 9 00 wn ave Cancel Test setup Illustration 6 20 Recipient Item Description Recipient id A preconfigured alias the name can be changed Recipient alias An alias to be used as a name reference for the recipient SMS The mobile number of the recipient including international country code E mail The e mail address of the recipient Language Defines the language in which the recipient wants to receive the message Time Specifies the time of day when the recipient wants to receive the notification This does not apply to event messages as they are sent according to the threshold speci fied in Messaging gt Event Test setup Tests the current recipient If both e mail and text messages SMS have been con figured a test e mail as well as a text message SMS will be sent Note Before the master inverter can send SMS messages a GSM modem together with a valid SIM card must have been installed and configured Refer to the GSM Manual L00410494 03 02 45 6 Setup Danfoss Note Before the master
55. l sweep Standard sweep Plant Inverter Use standard sweep to optimise yield when there are permanent shadows on the PV panel The characteristic will then be scanned at the defined interval to ensure production remains at the global MPP Procedure at plant and inverter level 1 Under Sweep Type select Standard sweep 2 Under Sweep Interval enter the desired sweep interval in minutes 3 Click on Save Note amp Select the sweep interval with care During the sweep inverter production will be reduced by up to 20 Therefore to ensure maximum overall yield an appropriate sweep interval is important The optimum interval will vary for each installation and can be established by ex perimentation Forced sweep Inverter Forced sweep operates independently of the standard sweep functionality and is intended for longer term evaluation of the PV panels The recommended procedure is to perform an initial forced sweep after commissioning and save the results in a log file Comparison of future L00410494 03_02 Darfi 6 Setup sweeps to the initial sweep will indicate the extent of power loss due to degeneration of the solar panels over time A forced sweep comprises the following steps 1 Disconnection of inverter from the grid 2 Measurement of open circuit voltage of the PV panels 3 Reconnection of inverter to the grid 4 Resumption completion of PV sweep 5 Resumption of no
56. lete list of the valid characters To add more inverters to the same group just enter the same group name for all inverters Inverters are delivered with the default group name Group 1 Inverter is master This check box needs to be enabled if this particular inverter is the master inverter in the network Enabling the master check box and pressing Save generates an automatic network scan and the Scan network button will appear Per default the master check box is unchecked Scan network Press this button to scan for connected inverters The names of the inverters found will appear in the list Check manually that all connected inverters have been found A network scan can be renewed at any time Newly found inverters will be added to the list and inverters not present in the network anymore will automatically be deleted from the list NOTE The Scan network button is only visible if the inverter is set up as the master inverter Show list Pressing the Show list button will open a pop up window which displays the names of all the inverters currently connected to the master together with their current status Via the pop up window it is possible to perform a quick communication check from the master inverter to the other inverters This is done by pressing the Check communication button NOTE The Scan network button is only visible if the inverter is set up as the master inverter 6 4 2 Date and Timeld 1 Plant Inverter
57. lishing access via the internet The Getting Started chapter explains initial setup and operation of the Web Server The remaining chapters explain functions in each menu The final chapter Site Map provides an overview of all menu items 1 1 1 Disclaimer Copyright and Limitation of Liability By using this manual the user agrees that the information contained herein will be used solely for operating equipment from Danfoss or equipment from other ven dors provided that such equipment is intended for communication with Danfoss equipment over an Ethernet serial communication link Danfoss does not warrant that a software program produced according to the guidelines provided in this manual will function properly in every physical hardware or software environ ment In no event shall Danfoss be liable for direct indirect special incidental or conse quential damages arising out of the use or the inability to use information con tained in this manual in particular Danfoss is not responsible for any costs includ ing but not limited to those incurred as a result of lost profits or revenue loss or damage of equipment loss of computer programs loss of data the costs to sub stitute these or any claims by third parties Names of products and companies mentioned in this manual may be registered trademarks of their respective owners Do not use data obtained from the inverter for billing purposes Data collected by the Tri
58. m amount and time to trip Modifications made to parameters at security level 2 are recorded See the section Change Log To change other functional safety settings refer to the TripleLynx Reference Manual 6 3 Relay 0 Inverter 6 3 1 Relay Functionality Alarm Inverter Configure the inverter relay for use with an external alarm or self consumption The default configuration is alarm enabled self consumption disabled Relay functionality Alarm Self consumption Status Enabled Disabled Alarm timeout s Illustration 6 10 Relay functionality Alarm To use this feature connect an external notification device e g a lamp to the relay output of the TripleLynx Pro inverter For further instructions on how to connect the device refer to the TripleLynx Installation Manual If the alarm is triggered it will remain active for the period of time defined under Alarm time out the value 0 disables the time out functionality and the alarm will sound continuously While the alarm is active it can be stopped at any time by pressing the Stop button The relay output can be tested by pressing the Test button The alarm is activated by the occurrence of a predefined inverter event Refer to the TripleLynx Reference Manual for a complete list of which events can enable the external alarm output of the TripleLynx Pro inverter L00410494 03_02 37 6 Setup Danfoss Note Z The external alarm functionali
59. message will contain a list of inverters and the corre sponding PV string where the production comparison has is sued the notification If there are no events the following text is shown All strings operating OK Inverter event List of inverters which have had events If there are no errors the following text is shown All inverters operating OK Inverter income deviation PV income deviation Table 6 3 Content of E mail Notification 6 8 Date and Time Plant See section Setup Inverter details Data and Time 6 9 Security Plant Inverter Enter the security password here The password defines the user security level ranging from 1 to 3 Changing the security level via the master changes the security level for every inverter in the network The current user access level is displayed in the footer of the Web Server as Security Level xx 52 L00410494 03 02 Danfots 6 Setup 6 10 Setup Details 01 Plant Inverter 6 10 1 Detailsl 1 Inverter Enter the language and grid code of the inverter here Language English F Grid Illustration 6 28 Setup Details Item Description Language Changes the display language inverter display and the default Web Server language Country Changes the current grid code of the inverter Note that this is a functional safety setting 6 10 2 10 Min Mean 2 Inverter The 10 minute average of the grid volta
60. on figuration Alternatively IP addresses can be administrated manually under Setup gt Communication gt IP setup View the inverter IP address via the display at Setup gt Communication setup gt IP setup Note g For manual configuration ensure that each inverter has a unique IP address 32 L00410494 03_02 6 2 3 6 2 4 Danfots 6 Setup Item Description Configuration Options e Manual e Automatic The following settings are obtained automatically if automatic configuration is selected otherwise they have to be entered manually They are only visible when Configuration gt Manual is chosen IP address IP address Subnet mask Subnet mask Standard gateway IP address of the Internet gateway This address can be requested from the network administrator DNS server This parameter can be requested from the network administrator Communication Channel Plant This menu item is available for TLX Pro and TLX Pro only Selection of a communication channel is the first step in configuration of email transmission and FTP upload Communication channel Local network Illustration 6 5 Communication Channel Item Description Communication channel Select the desired communication channel for FTP upload and email transmission Select GSM or Local network Default is Not present Procedure Select GSM to tran
61. oss Solar Inverters A S Safety test passed Illustration 2 1 Product Label 6 The Web Server logon dialog opens 7 Type admin in the user and password fields and click Log in 8 At initial logon the inverter runs a setup wizard 2 1 2 Setup Wizard Step 1 of 7 Master setting To set up a master inverter click on Set this inverter as master A scan runs to identify inverters in the network 8 L00410494 03_02 Danfoss 2 Getting Started A pop up window shows the inverters successfully identified Click OK to confirm that the correct number of inverters has been found Setup Wizard Step 1 of 7 To establish the master inverter click on set this inverter as master A network scan will begin Next Illustration 2 2 Step 1 of 7 Master Setting To change this setting later refer to Setup Inverter Details Step 2 of 7 Display language Select display language Note that this selection defines the language in the display not the grid code The default language is English Setup Wizard Step 2 of 7 Display language English v Previous Next Illustration 2 3 Step 2 of 7 Display Language To change the language setting later refer to Setup Setup Details Step 3 of 7 Time and date Enter time in 24 hour format date time zone Accuracy is important because date and time are used for logging purposes Adjustment for da
62. part number 0 CTRL Com board part number 0 COMM 0 PCB software versions Control board 0 CTRL Functional safety processor 0 FSP Display software version 0 DISP Communication board 0 COMM Table 8 8 Inverter View Continued 70 L00410494 03 02 Danfots 8 Appendix A Sitemap Main Menu Horizontal menu Page content b 1 Operating time Power board 1 POW h AUX board 2341 h 1 AUX h Control board 2341 h 1 CTRL h Communication board 1 COMM h Submenu 0 PV Sweep 0 Status 0 PV1 Timestamp 0 PV1 Umpp 0 PV1 Impp 0 PV1 Pmpp 0 PV1 FF 0 PV1 Uoc 0 PV1 Isc 0 PV1 FF 0 PV1 Status 0 0 PV3 12 5 KW and 15 kW ratings only Table 8 9 Inverter View Continued L00410494 03 02 71 8 Appendix A Sitemap 72 Darfi Main Menu Horizontal menu Page content 0 Log 2 Submenu 0 General 0 Total Production kWh 0 Total Operating time h 1 Derating 1 Off grid counter 1 Total de rate h 1 Grid voltage h 1 Grid current h 1 Grid power h 1 PV current h 1 PV power h 1 Internal temperature h 1 Power level adjustment h 1 Frequency stabilization h 1 Reactive power h 0 Data log Displays the overall content of the data log individual log records are viewed when exporting the log 0 Production log This log displa
63. pleLynx inverter regarding the power generated by the PV plant may deviate from those displayed by the energy meter with up to 3 Values are calculated on the basis of active power unless otherwise indicated L00410494 03 02 5 1 Introduction 1 1 2 1 1 3 Darfi Symbol Explanatory note Italics 1 Indicates reference to a section of the present manual 2 Italics are also used to indicate an operation mode e g operation mode Connecting used in text 1 Encloses a path of menu navigation 2 Also used to enclose abbreviations such as kW x superscripted in headlines Indicates security level Plant Menu item accessible at plant level Group Menu item accessible at group level or above Inverter Menu item accessible at inverter level or above gt Indicates a step within menu navigation Note useful information I Caution important safety information Hu Name of plant group or inverter in sms or e mail mes sage eg plant name Site Map Symbol Explanatory note b Indicates a submenu x Defines current security level where x is between 0 3 Table 1 1 Symbols List of Abbreviations APN Access point name for GPRS DW upload Data warehouse upload of logged inverter data also known as web portal upload DHCP Dynamic Host Configuration Protocol
64. pload time FTP server address FTP server port FTP mode FTP user name Password Password again oosoosoo oooooo SELSLLE8 2208 0 SMTP Setup esse nrag Submenu Nominal Plant AC power Q and PF settle time Control type Reference value 1 Constant reactive power Q visible for Ref value set to Reac tive Power Q 1 Constant power factor PF visi ble for Ref value set to Power Factor PF K1 K2 K3 K4 Power level Reactive power Q 1 Grid Management 1 General 1 Relay configuration this menu is available when Gen eral Reference value Danfoss Grid Management Box Power Factor PF 1 PF P curve 1 Up to nine data sets of this menu is available when Gen Nominal plant AC power and Pow eral Reference value Set point er Factor PF curve PF P 1 Q U curve 1 Up to nine data sets of this menu is available when Gen plant nominal AC voltage and Re eral Reference value Set point active Power Q curve Q U 1 Fallback values ee L m m Set point type Table 8 3 Plant View Continued L00410494 03_02 65 8 Appendix A Sitemap Danfoss Main Menu Horizontal menu Page content 0 Setup Submenu 0 Messaging 0 Recipient 0 Recipient ID 0 Recipient Alias 0 Language 0 SMS 0 Email 0 Time 0 Yield 0 Notification 0 Interval 0 Li
65. rmal production Procedure 1 Click on Force Sweep L00410494 03_02 61 7 Remote Connection Darfi 7 Remote Connection 7 1 Remote Connection For network management purposes the following inverter ports are used for communication Application Protocol Default Port No WEB TCP UDP 80 fixed FTP TCP UDP 21 changeable via Setup Communication gt Data warehouse on plant level SMTP TCP UDP 25 changeable via Setup gt Communication gt SMTP on plant level EtherLynx UDP 48004 fixed Consult the ISP for proper installation of the modem and router For support of third party equipment refer to the network administrator Note amp Inverter Ethernet communication is not protected against internet hazards Therefore imple mentation of IT safety precautions is required before connecting the inverter to the internet These precautions include firewall VPN etc 62 L00410494 03 02 Danfots 8 Appendix A Sitemap 8 Appendix A Sitemar 8 1 Plant View x Defines current security level where x is 0 1 or 2 Defines whether this page is shown when logged in as user Main Menu Horizontal menu Page content 0 View b Submenu 0 Overview Displays the main page with over all plant status information F Displays daily monthly and yearly 0 Dail 0 Production graphs 0
66. roduction at global MPP FF Fill factor Pmpp Uoc Isc Uoc V Open circuit voltage at global MPP Isc A Short circuit current at global MPP Number of MPP Total of global and local MPP detected Status Confirmation of successful PV sweep PV3 Timestamp hh mm ss Time of most recent PV sweep Umpp V DC voltage at global MPP Impp A Current at global MPP Pmer W Power production at global MPP FF Fill factor Pmpp Uoc Isc Uoc V Open circuit voltage at global MPP Isc A Short circuit current at global MPP Number of MPP Total of global and local MPP detected Status Confirmation of successful PV sweep Plant level The plant level view displays the same data as at inverter level for each inverter in the solar power plant For further information about PV sweep functionality refer to the section Status PV Sweep 4 11 Plant Status Plant The plant status report details energy production for the overall plant and also individual PV in puts and individual inverters The report provides the information required to identify failures due to soiling partial failure of solar cells and faulty inverter circuits 24 L00410494 03 02 Danfots 4 Status This report is also available as an email message For further information refer to the section Setup Plant status Item Unit Description Plant name Name of PV plant Report date Date of report Report period Duration of period covered by report
67. rted Letters abcdefghijklmnopqrstuvwxyz Capital letters ABCDEFGHIJKLMNOPQRSTUVWXYZ Numbers 0123456789 Special characters _ Note No spaces are allowed in inverter name L00410494 03_02 2 Getting Started Danfoss 2 Getting Started 2 1 Access and Initial Setup 2 1 1 Access via PC Ethernet Interface Change the Web Server logon and password of the master inverter immediately for optimal security when connecting to the internet To change the password go to Setup Web Server Admin Setup Sequence 1 Select which inverter will be set up as master 2 Open the cover of this inverter Refer to the TripleLynx Installation Manual for instruc tions 3 Connect the inverter RJ45 interface to the PC Ethernet interface using a patch cable network cable cat5e crossed or straight through 4 On the PC wait until Windows reports limited connectivity if no DHCP is present Open the internet browser and ensure pop ups are enabled 5 Type http invertername in the address field Find the serial number on the product label located on the side of the hous ing Invertername is the final 10 digits of the serial number 1 Type TLX 10kW PV input 1000 VDC max 3 x 12 A 250 800VDC MPP Output 3 x 400 VAC N PE 50 Hz Class I 10 kW nom 3 x 15 A max Chassis IP54 Temp 25 C to 60 C SEU TUT lem 139F0001123402G210 CE VDE0126 1 1 Made in Denmark Dant
68. s used A maximum of 24 charac ters can be entered Password The password for the FTP web portal account A maximum of 24 characters can be entered Start log upload now Tests the FTP upload immediately To check status go to Plant gt Status gt Upload status Note A prerequisite for a successful data transfer to the data warehouse is a valid and active por tal account Receive further details directly from the data warehouse web portal provider When registering the inverter at a data warehouse web portal provider the serial number of the inverter which sends the data to the portal is often needed In this case it is the serial num ber of the master inverter The serial number of the inverter can be found via Status gt Inver ter or on the name plate on the side of the inverter Use the last 10 digits 36 L00410494 03 02 Danfots 6 Setup 6 2 7 Remote Access 1 Inverter As per default it is not possible to change the functional safety settings of the inverter via the Web Server To be able to do so enable the remote access check mark Note that this must be done individually for each inverter in the system Change functional safety settings Enable e Disable c Illustration 6 9 Change Functional Safety Settings The following functional safety parameters can be set here Rate of change of frequency maximum amount and time to trip 10 minute mean value of grid voltage maximu
69. smit FTP upload and emails via the optional GSM modem Select Local network to transmit FTP upload and emails via Ethernet Email and FTP upload configuration Selection of a communication channel is required to define a route for email transmission and or FTP upload To fully activate email communication or FTP upload additional configuration is required For further information refer to the sections GPRS Setup SMTP Setup and Data Warehouse FTP Upload Note that when the communication channel is set to Not present no FTP upload or email transmission will take place even when GPRS SMTP and or Data Warehouse are configured SMS configuration For SMS communication no communication channel setting is required For configuration of SMS communication refer to the section Recipient GPRS Setup l Plant Configure the GPRS settings of the inverter here They are required so the GSM modem can connect to the internet to send e mails or upload data to a web portal or FTP server L00410494 03 02 33 6 Setup Darfi This menu is visible when the master inverter is equipped with a GSM modem and a valid SIM card SIM pin code 1234 Access point name GPRS Internet User name users Password f res Password again feccoere i Network roaming C Illustration 6 6 GPRS Setup for GSM networking Note amp In order for messaging or DW upload FTP server upload
70. son for the plant status report 30 L00410494 03 02 6 1 3 Illustration 6 2 PV Array Darfi PY1 array area PY1 array power PY2 array area PY2 array power PY3 array area PY3 array power 40 0 m2 6000 wW 40 0 m2 6000 wW 40 0 m2 6000 wW Item Unit Description PV1 array area m2 Input 1 total PV array area PV1 array power WwW Input 1 total rated output of PV panels PV2 array area m2 Input 2 total PV array area PV2 array power Ww Input 2 total rated output of PV panels PV3 array area m2 Input 3 total PV array area PV3 array power W Input 3 total rated output of PV panels Environment Plant Inverter Via the environment menu in plant view the values for total reimbursement and total CO2 emis sion can be configured Start value for yield count Reimbursement ct kWh CO emission factor Cancel Illustration 6 3 Calculation Values kwh p 00 Je cent kg kwh Item Unit Description Start value for yield count kWh Defines the value an offset from where the yield count used in the calculation of reimbursement and CO2 emission begins Reimbursement ct kWh Euro cent per KWh Defines a value for the financial yield Note Defining this value requires considerable knowl edge of the individual reimbursement models of the different countries The default value is 0 00 CO2 emissions factor
71. st of recipients 0 Event 0 Notification 0 Threshold 0 List of recipients 0 DW Upload 0 Notification 0 List of recipients 0 Performance ratio 0 Notification 0 List of recipients 0 Performance ratio 0 Communication error 0 Notification 0 List of recipients 0 Data overwrite 0 Notification 0 List of recipients 0 Plant status 0 Notification 0 Interval 0 Income deviation 0 PV deviation 0 List of recipients Submenu 0 Date and time Changes the date and time set tings for the entire plant 0 Plant details Here the name of the plant is specified 0 Security Changes the plant access level 0 Setup details 0 Power level adjustment Here the current relay configura tion is specified 1 Service 1 Replicate Replicates the installation settings of the master inverter to the other inverters 0 Web Server 0 Admin Changes the admin password p 0 Users Defines new users 0 Profiles Defines the current user profile which group of inverters can the particular user see 0 PV Sweep 0 Sweep type 0 Sweep interval Table 8 4 Plant View Continued 1 PV3 is not displayed for inverter rating 10 kW 2 TripleLynx Pro only 66 L00410494 03 02 Danfots 8 Appendix A Sitemap 8 2 Group View Main Menu Horizontal menu Page content 0 View is Submenu 0
72. tate is ignored considered off Power level in PLA setting Output power reduction as percentage of the plant nominal AC power rating 6 11 1 Replicate 1 Plant To make the configuration of the TripleLynx Pro inverter easier for installers and service techni cians in connection with either commissioning or service it is possible to distribute replicate the general settings of the master inverter to the other inverters in the network It is not possible to choose to only replicate some of the settings all the settings specified are replicated Specify which inverters to replicate to These settings can be replicated from the master to any inverter in its network Time and Date Setup details Language E Country Messaging Logging interval Environmental settings settings for revenue and CO2 emission L00410494 03_02 55 6 Setup Darfi Note It is only possible to replicate the settings of the master inverter to the other inverters in the network 6 11 2 Settings Backup nverter When settings are changed the inverter backs up its production log and updates settings stor ed in the display unit Stored data are Timestamp Setup details Language Country PV Configuration Energy production log Irradiation log Communication setup RS485 network address IP configuration IP address Inverter details Inverter name Group name Inverter type
73. the entire plant This value is necessary for correct calculation of the absolute reactive power Q Q and PF settle time Enter the system settling time for reactive power regulation Range 10 60 seconds Control type Specifies whether the control should be Open loop enabled or Off disabled Reference value Select a reference for reactive power e Grid management box e Reactive power Q e Power factor PF e Setpoint curve PF P e Setpoint curve Q U Grid management box The grid management box receives setpoint values for reactive power and PLA from the DNO Configure the grid management box inputs under Relay configuration For more information refer to the TripleLynx Reference Manual and the Danfoss Grid Man agement Box Manual Reactive power Q Enter the fixed setpoint value for the plant reactive power Q as either L00410494 03_02 41 6 Setup 6 6 2 42 Darfi percentage value of the nominal plant AC power Range 0 60 of the nominal plant AC power over excited or under exci ted value of Q kVAr Power factor PF Enter the fixed setpoint value for the plant power factor Range 1 0 8 over excited or under excited Setpoint curve PF P The power factor is defined as a function of the plant output power Enter the values for the setpoint curve under PF P Curve Setpoint curve Q U Reactive power is defined as a function of the grid voltage either as
74. thentication type exclusively SMTP authentication is supported If the authentication check box is checked remember to enter the ac count information of the e mail This information will be forwarded by the internet provider L00410494 03_02 35 6 Setup Panfot 6 2 6 Data Warehouse l Plant FTP Server Upload Upload interval Daily v Upload time 23 hr 59 min FTP server address www meteocontrol de FTP server port 21 FTP mode Active FTP server user name 27810QP3310 Password 20000000 Password again 00000000 Start log upload now Illustration 6 8 Data Warehouse Item Description Upload timel Time of day when the upload takes place only used when upload interval is configured to daily Upload intervall Hourly Daily Weekly Monthly Disabled FTP server addressl The FTP server address is user configurable It can be a name or IP address A maximum of 24 characters can be entered FTP server port FTP server port is user configurable Default port is 21 FTP model FTP connection mode is user configurable The following options exists Passive Active Default mode is Active FTP server user namel Both the user name and the password for the FTP session web portal upload established by the TripleLynx Pro inverter can be configured by the user If empty the serial number of the inverter i
75. ther printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved Rev date 2011 11 01 Lit No L00410494 03_02
76. ty only works per individual inverter it cannot be configured on plant basis 6 3 2 Relay Functionality Self consumption Inverter Relay functionality Alarm Self consumption Power level W Duration m Trigger time 0 P 0 2 Illustration 6 11 Relay Functionality Self consumption Item Unit Description 0 Power level Ww Minimum output power level at which the relay must activate 0 Duration minutes Time minutes the output power must be above the minimum output power level 0 Trigger time hh mm ss Time of day the relay must activate Self consumption is applicable when a power consuming unit is connected to the inverter By default the self consumption functionality is disabled To enable self consumption go to Inverter gt Setup gt Relay gt Relay functionality and select Self consumption Once enabled the self consumption functionality is activated by output power level or a time of day Set up the conditions for activation as follows Output power level Set Power level to the desired minimum output power level for activation of self consumption The default value of Power level is 3000W Set the Duration period Self consumption will activate when output exceeds the minimum power level for the period defined in Duration The default value of Duration is 1 minute The Duration function serves to avo
77. verter Grid Management Plant Generalli1 Plant Relay Configuration Plant Setpoint Curvesli1 Plant Fallback Values Plant Messagingl01 Plant Inverter Recipient Plant Yield 0 Plant DW Upload Plant Performance Ratiol Plant Communication Errorl01 Plant Data Overwritel l Plant Plant Status Plant Date and Timel01 Plant Security Plant Inverter Setup Details 0 Plant Inverter Details Inverter 10 Min Mean 2 Inverter ROCOFI2 Inverter PV Configuration Inverter Servicel11 Plant Replicate 1 Plant Settings Backup inverter Settings Report Inverter Web Serverl Plant Adminl01 Plant L00410494 03 02 Contents 34 36 37 37 37 38 38 38 39 40 40 40 41 41 41 42 43 44 44 45 46 47 48 49 49 49 52 52 53 53 53 53 54 55 55 56 57 57 57 Contents Users Plant Profilest Plant Plant Details Plant Inverter PV Sweep l Plant Inverter 7 Remote Connection Remote Connection 8 Appendix A Sitemap Plant View Group View Inverter View L00410494 03 02 58 58 59 59 62 62 63 63 67 68 Danfoss 1 Introduction 1 Introduction 1 1 Introduction These instructions describe the TripleLynx Pro Web Server and explain how to use it Refer to the download area at www danfoss com solar for the newest instructions The Remote Connection chapter contains information for estab
78. via GSM to work it is essential that the GPRS setup has been configured correctly Item Description SIM pin code Here the SIM PIN code is entered if applicable The PIN code can consist of 4 8 characters Access point name Connection information from the GPRS service provider This information together with a user name and password can be requested by the SIM card supplier and is needed in order for the inverter to be able to dial in to the internet Max 24 characters User name User name assigned by the GPRS service provider Max 24 characters Password Password assigned by the GPRS service provider For security reasons every password char acter is displayed as an asterisk Password again Retype the password Network roaming e Checked Enabled e Not checked Disabled Per default the network roaming check box is not checked If checked the GPRS modem is allowed to connect to the internet via a network which is not the home network a network which does not belong to the network of the telephone compa ny Roaming is not a free service and the telephone company will most likely impose extra charges 6 2 5 SMTP Setup Plant In the SMTP setup menu the mail server settings for exchanging e mails are specified Parame ters here include SMTP server logon password sender address and authentication type 34 L00410494 03 02 Danfots 6 Setup
79. ylight savings is automatic L00410494 03 02 9 2 Getting Started Danfoss Time hh mm ss 17 I 14 Date dd mm YYYY 21 11 2010 TimeZone GMT 1 Previous Next Illustration 2 4 Step 3 of 7 Time and Date To change these settings later refer to Setup Inverter details Set Date and Time Step 4 of 7 Installed power For each PV input enter surface area installed power For more information refer to the TripleLynx Reference Manual I Incorrect setting can have serious consequences for production efficiency Setup Wiz P 1 array area 40 0 m2 PY1 array power 6000 wW PV2 array area 40 0 m P 2 array power 6000 wW PY3 array area 40 0 m PY3 array power 6000 wW Previous Illustration 2 5 Step 4 of 7 Installed Power To change the installed power refer to Setup Calibration PV Array 10 L00410494 03_02 Danfoss 2 Getting Started Step 5 of 7 Grid code Select the grid code to match the location of the installation To meet medium voltage grid re quirements select a grid code ending in MV The default setting is undefined Select the grid code again to confirm The setting is activated immediately Correct selection is essential to comply with local and national standards Grid Germany Previous Illustration 2 6 Step 5 of 7 Grid Code
80. ys the accumulated production data for the past 20 years This log can be exported 0 Irradiation log Provided an irradiation sensor is installed on the inverter this log displays the accumulated irradia tion data for the past 20 years This log can be exported 0 Event log Displays the latest 20 inverter events The complete event log can be viewed when exporting the log 1 Change log This log contains an entry for ev ery time any of the functional safe ty related parameters of the inver ters has been changed The Web Server displays the latest 20 events the complete change log can be viewed when exporting the log 0 Grid management log The grid management log contains an entry for every time the inver ter has received a power reduction telegram The Web Server only displays the latest 20 events the complete log can be viewed when exporting the log 0 Reactive Power 0 Reactive energy underexcited kVArh 0 Reactive energy overexcited kVArh Table 8 10 Inverter View Continued L00410494 03 02 Darfi 8 Appendix A Sitemap Main Menu Horizontal menu Page content 0 Setup b Submenu 0 Calibration 0 Sensors oO 0 Irradiation sensor scale mV 1000 W m 0 Irradiation sensor temp coeff C PV temp offset 2 C Ambient temp offset C SO scale pulses kWh j 0 PV Array 0