Home

WS2306 Quick Manual - Wireless Weather Station with Weather Boy

image

Contents

1. o e oo Battery Compartment Sensor sockets e Base Station o lo N E O N Battery Sockets o b compartment and PC FB COM port gt CO Ya y N o ki Setting up using batteries 1 Sensors Pull and remove the protective rain cover to reveal three socket ports and the battery cover Insert the cables of the wind and rain sensors in the correctly marked sockets Slide open the battery compartment and checking the correct polarity insert 2 x AA LR6 1 5V batteries and replace the cover and rain cover 2 Base Station Now open the battery cover at the back of the unit and checking the correct polarity insert 3 x AA LR6 1 5V batteries and replace the battery cover Setting up using the AC DC power adaptor 1 Sensors Set up the sensors as described above in Setting up using batteries 2 Base Station Using the AC power adaptor included in this set plug it into mains supply and connect it to the 6 0V DC adaptor socket located at the side of the base station Performing a function test After powering up the units the base station has to synchronize to the sensors before the weather data can be received The synchronization mode lasts for 15 minutes During the synchronization mode perform the following function test to check operation 1 Check that the wind vane and fan of the wind sensor can freely rotate by moving the vane gently and also blowing into the fan to em
2. WIRELESS WEATHER CENTRE WS2306 Quick Set Up Manual 12 34 00 PR 10 10 TENDENCY LA CROSSE TECHNOLOGY Quick Set Up Manual Weather Station Using cable connection or 433MHz for wireless transmission of weather data this unique weather station can be powered using batteries or AC power or r needs in the home or office both at the same time for all your w Open carefully and check that the following contents are complete ltem Consisting of Fittings Illustration Base 1 Main unit 1 AC DC 240V Station power Adaptor optional use included Thermo 1 Main unit 1 10 metre cable Hygro 2 Rain protection optional Sensor cover connection to the base station included 2 Wall mounting screws 3 Plastic anchors for screws Wind 1 Main unit with 1 1 x U bolts for Sensor wind vane mast holder 2 10 metre cable 2 2x Washers already attached 3 2x Nuts E 4 to the main unit 4 2x cable ties Ft 3 Mast holder Rain 1 Base and funnel Sensor 2 10 metre cable already attached to the main unit Heavy CD ROM 1 2 metre computer Weather English version only cable for PC Q7 RO PC function only Z software optional use included Setting Up Important Operating power is supplied to both the wind and rain sensors by the thermo hygro sensor Thermo Hygro Sensor Battery Cover
3. nits can be positioned virtually anywhere to within a 100m radius of the base station so decide which method is best suited to you For cable connecting please ensure that the 10 metre cable included in this set meets with your distance requirements see accessories in the main user manual for adding extension cables To change from 433MHz to cable connection or vice versa simply connect or disconnect the 10 metre cable from the base station to the sensor The base station will automatically detect the connection and read the weather data If the data cannot be received then press and hold the PLUS key for 2 seconds to synchronize the base station with the sensor Important Ensure all signals can be received and or all cable distances meet with your requirements at the point of fixing particularly before you start drilling any mounting holes Wind sensor Secure the main unit to the shaft of the mast holder using the single screw provided with the front of the sensor marked E facing in the East West direction otherwise wind direction will not be accurate Now fix the entire unit to a suitable mast using the U bolt 2 washers and nuts or the 2 cable ties found in this set Note For best results mount the wind sensor onto a mast to allow the wind to freely travel from all directions to enable an accurate reading ideal mast size should be from 81 9 0 4 m Ensure that the 10 metre cable of the wind sensor meets your distance req
4. uirements Rain sensor The rain sensor should be mounted horizontally about 0 6 0 9m off from the ground in an open area away from trees or other coverings to allow rain to fall naturally for an accurate reading Note For best results ensure the base is horizontal to allow maximum drainage of any collected rain Thermo hygro Sensor To wall mount the thermo hygro sensor fix the wall holder onto the desired wall 2 screws are supplied plug the sensor firmly into the wall holder and then carefully replace the rain cover back over the thermo hygro sensor Note After mounting the units should the weather data not be received then press and hold the PLUS key for 2 seconds to synchronize the base station with the sensor Weather station for use with your PC Use your PC to read the latest weather data collected by the weather station Just simply install the software from the enclosed CD ROM onto your PC For full details see the Heavy Weather PC software instructions in the CD ROM English version only System Requirements The minimum system requirement for use of Heavy Weather PC software is Operating system Windows 98 or above Processor Pentium 166 MHZ or above processor RAM 32MB or above Hard disc 20MB free space CD ROM drive Distributed by Sontax Australia Phone 1800 653 238 Email sales sontax com au Website www sontax com au Printed in China
5. ulate wind speed and direction 2 Holding the rain sensor in both hands with the longest side facing you tilt the unit from side to side and hear the rain counter flip which emulates rainfall 3 The base station will start to receive the 433MHz data transmitted from the sensors Data such as rainfall will not be updated as regularly as lets say the outdoor temperature since it does not rain constantly all the time and therefore these readings may take up to two minutes before being shown on the LCD 4 Now using the DISPLAY key on the base station toggle between different weather modes on the LCD to check that the weather readings can be received for the relevant sections for example outdoor temperature and humidity etc Note Should any outdoor data not be received from the sensors when is displayed then check all cables are correctly inserted and press and hold the PLUS key for 2 seconds to hear a beep and the base station will synchronize to the sensors transmitting signal Wind speeds that read zero does not mean reception failure it simply means that there was no wind at the time of reading the data Mounting the units Users must take their living surroundings into consideration before deciding which method is best suited for them Connection by cable is advantageous in that data from the sensors to the base station is interference free Using 433MHz wireless transmission gives users little restriction so that all u