Home
SLC-600, 1200, 1800 User Manual
Contents
1. even when the AC mains or generator voltage is extremely low or extremely high There are four stages of boost normal and buck drop operations regulating the output of the SLC within 105 to 130VAC even when the input voltage varies from 75 to 150VAC For 230V models the output voltage is regulated within 200 to 250VAC even when the input voltage varies from 150 to 280VAC Furthermore the SLC filters noise and arrests surges spikes to to protect your sensi tive equipment BEFORE INSTALLATION Please unpack the SLC from the packing box and inspect the unit for shipping damage If damage is found notify the carrier and your dealer Otherwise save the packing box and material for later use You must ship the unit in its original or equivalent packing material for any war ranty work to be performed INSTALLATION INSTRUCTIONS 1 Make sure the unit is turned off Place the SLC within 2 meters 6 feet of a grounded 3 wire electrical outlet 2 IMPORTANT Before plugging in the SLC into the electrical outlet make sure that the utility voltage is appropriate for the specific SLC model The proper power and voltage of your model are printed in the rear panel label You can also check the power and voltage table printed in this manual 3 Plug in the SLC into the power outlet Next plug in the equipment to be protected into the SLC s outlets Make sure that the maximum power rating of the SLC is not exceeded 4 Turn on the SLC with
2. 600 1200 1800 SLC 600E 1200E 1800E TSi Power Corporation 1103 West Pierce Antigo WI 54409 U S A Phone 715 623 0636 FAX 715 623 2426 Internet www tsipower com e mail sales tsipower com Copyright 1997 TSi Power Corporation All rights reserved TSi Power s ongoing product improvement process makes specifications subject to change Other company s product names herein are for identification purposes only and may be trademarks of their respective companies Super Line Conditioner IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS FOR YOUR SUPER LINE CONDITIONER THAT SHOULD BE FOLLOWED DURING INSTALLATION AND MAINTENANCE PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR SUPER LINE CONDITIONER CAUTION The 3 wire power cord supplied with the unit pro vides earth ground for the unit s chassis to prevent electrical shock Plug the unit into a 3 wire commercial grounded AC receptacle with the grounding conductor connected to earth ground at the service equipment Removal of the grounding pin from the plug or use of a 3 wire to 2 wire adaptor may result in a shock hazard CAUTION Hazardous voltage inside Do not remove cover There are no user serviceable parts inside All repairs should be performed by trained service personnel INTRODUCTION Your TSi Power Super Line Conditioner SLC is designed to provide computer grade power
3. INPUT FREQUENCY INPUT VOLTAGE RANGE OUTPUT VOLTAGE RANGE EFFICIENCY TRANSFER TIME RESPONSE TIME HYSTERESIS SPIKE amp SURGE PROTECTION NOISE FILTERING TEMPERATURE RANGE HUMIDITY SIZE WEIGHT SPECIFICATIONS 50 60 Hz 75 150VAC 120V models 150 280VAC E amp EC models 105 130VAC 120V models 200 250VAC E amp EC models Higher than 97 under full load Less than 2ms from one mode to next Within 2 cycles of new input AC before switching over to a new mode Minimum of 6V to prevent unnecessary switchovers caused by momentary sags on AC line commonly induced by copiers and laser printers This will improve reliability of both line conditioner and equipment Extremely fast solid state surge suppressor responding within nanoseconds to shunt upto 26000 amps of surge current or upto 280 Joules of energy Custom EMI RFI noise filter provides upto 45 dB of common mode attenuation and 35 dB of differential mode attenuation at 1OMHz OPERATING 20 C 50 C STORAGE 40 C 60 C 0 95 relative humidity non condensing WIDTH 6 152 mm HEIGHT 4 102 mm DEPTH 8 203 mm SLC 600 600E 600EC 8 Ibs 3 6 kg SLC 1200 1200F 1200EC 11 Ibs 5 0 kg SLC 1800 1800F 1800EC 15 Ibs 6 8 kg LIMITED WARRANTY TSi Power warrants this product to be free from defects in materials and workmanship for two 2 years from the date of pu
4. range of the UPS minimize battery usage and provide even greater protection to your equipment For an UPS to work with most effectively with a SLC the SLC should be plugged into the wall and the UPS should be plugged into one of the outlets of the SLC CAUTION Do not plug in the SLC into the output sockets of an UPS Doing so could prevent the SLC from providing the maximum range of voltage regulation and filtering You will also lose the benefit of using the SLC to reduce the need for the UPS to operate on battery POWER AND VOLTAGE MODEL POWER NOMINAL OUTPUT NUMBER in Watts VOLTAGE SOCKETS SLC 600 600 120V 50 60Hz 4 x NEMA 15R SLC 1200 1200 120V 50 60Hz 4 x NEMA 15R SLC 1800 1800 120V 50 60Hz 4 x NEMA 15R SLC 600E 600 230V 50 60Hz 4 x IEC 320 SLC 1200E 1200 230V 50 60Hz 4 x IEC 320 SLC 1800E 1800 230V 50 60Hz 4 x IEC 320 SLC 600EC 600 230V 50 60Hz 2 x SCHUKO SLC 1200EC 1200 230V 50 60Hz 2 x SCHUKO SLC 1800EC 1800 230V 50 60Hz 2 x SCHUKO AC OUTPUT SOCKETS n LA NEMA 15R SCHUKO IEC 320
5. rchase from TSi Power or its authorized representatives TSi Power will repair or at its option replace any defective component s during this warranty period To make a request or claim for service under this limited warranty the original purchaser must return the product in the original shipping container or equivalent to TSi Power or its authorized distributor accompanied by a written receipt showing the date of purchase dealer s name and both the model name and serial number of the product Warranty does not cover transportation costs Damage by misuse acci dent or unauthorized tampering of the product is not covered by the war ranty NO OTHER WARRANTIES ARE EXPRESSED OR IMPLIED TSI POWER IS NOT LIABLE FOR CONSEQUENTIAL DAMAGES THIS WAR RANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE LIMITATION OF LIABILITY IN NO EVENT SHALL TSI POWER OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUP TION LOSS OF BUSINESS INFORMATION OR OTHER PECUNIARY LOSS ARISING OUT OF THE USE OR INABILITY TO USE THIS TSI POWER PRODUCT EVEN IF TSI POWER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOME STATES DO NOT ALLOW THE LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU TSi POWER Operating Manual SLC
6. the power switch One of the four indicator lights will turn on Which one will turn on depends upon the condi tion of the utility voltage see section below on indicator lights Your equipment connected to the SLC are now ready to be turned on INDICATOR LIGHTS The front panel indicator lamps display the status of the SLC in the following manner BOOST2 This light is on when the AC input voltage is ex tremely low requiring a 2nd stage of boost in order to raise the voltage to normal levels BOOST1 This light is on when oos the AC input voltage is moderately low requiring single boost stage in order to raise the voltage to normal levels NORMAL This light is on when the AC input voltage is normal and no boost or buck is required BUCK This light is on when the AC input voltage is too high and thus requires a buck stage to reduce the voltage to normal levels AC FUSE In case of an overload the input fuse will open and none of the front indicator lights will be on even if the power switch is turned on and the SLC is plugged in To replace the fuse first unplug the SLC from the wall remove the fuse from the rear panel and replace with a fuse of the same type and rating printed adjacent to the fuse cap HOW TO USE AN UPS WITH YOUR SLC An Uninterruptible Power Supply UPS can provide AC power to your equipment during power outages or fluctuations Your SLC working together with an UPS can increase the operating
Download Pdf Manuals
Related Search
Related Contents
Solo_Duetto -IT - schede Philips Drip tray grey HD5235 Garmin ecoRoute ecoRoute Supplement User Manual Operating Instruction ~ Dental Lab Work Station ~ Garantía Wattio NGS Expression 12" GNU Emacs Manual DSC-TX300/TX300V RV Manual doméstica elgin decora – jx-2080 Copyright © All rights reserved.
Failed to retrieve file