1. select up to 9999 Litres easy to connect disconnect ME3000 Batch Controller PMS Electromagnetic flowmeter obstructionless bore virtually maintenance free robust construction e high level of performance available in various sizes g ua for heavy recycled water e ideal for outdoor use IP64 front face set batch quantity via touchpad e fully programmable Many safety features displays in either Litres or millilitres easy to connect disconnect e interchangeable with ME995 7 Same size and connection TM 41 Carter Road Brookvale Manutio Sydney NSW 2100 Australia Flow Measurement amp Control Products Ph 61 2 9905 4324 9938 1425 a division of Fax 61 2 9938 5852 MANU ELECTRONICS PTY LTD Web www manuelectronics com au E Page 10 Email sales manuelectronics com au Please see our website www manuelectronics com au for full specifications and other products
2. CONNECTION DIAGRAM TO MANUFLO ME2000 ME2008 BATCH SAFETY UNITS ME2008 2 channel module e m gg a Ths I je i AN it e B Ua DAS D pa a ey FN be a Y i or ENS ELECTRONICS HL d A L d ME2 0 DISPLAY C Ou KA ii U6 rLZL Z X5 Pi L N SHIELD S P SHIELDED CABLE EARTHED X ajl N Q Lu LLI e wt t a gt JE REEE ME6008M t existing wiring 240 vac 2 channel module 2 channel module v 2 TO O E c c o X N 123 45 6 7 8 SH 12V SINKING PULSE E SHIELD PULSE 1 12 VDC NI SHIELD V DB9 Female MSESSSI x 4 s d 2 FLOWMETER 1 FLOWMETER 2 240vac Typically existing MES type flowmeters N DB25 Male PRINTER EPSON LX300 I The flowmeter PULSE and 0 V are parallelled from the 2 channel modules to the ME6008M a division of Mami io C MANU ELECTRONICS PTY LTD Flow Measurement amp Control Products Page 4 www manuelectronics com au SCREEN 2 COUNT MODE CH01 000000 L PRT NXT RST DNE D to screen 1 SCREEN 3 CLEAR BATCH YES SCREEN 8 NEXT BATCH 0055 INC SHF DNE A B C D to screen 1 SCREEN 9 FLOW SETTINGS SET DNE A B C D SCREEN 10A CH01 0001 00 PPU INC SHF NXT DNE A B C D to screen 1 SCREEN 10B A B C D to screen 1 SCREEN 10C CHO01 40 pulses INC SHF NXT DNE D to screen 1 Manutio a Flow Measurement amp Control Product
3. mL L L AE ee 5 L se m o00 00 OL B 0001 20 06 11 10 34 000000 000349 000000 000000 000000 000000 000000 000000 o509 20t ocovosomt odoosvor 0909090mLl 0002 EZ Ucar 43 1 10 49 B 0002 20 06 11 10 34 000000 000000 000450 000000 000000 000000 000000 000000 EET EESE Fee ss POALE cea beewe Manuo om a division of Irama ru MANU ELECTRONICS PTY LTD Flow Measurement amp Control Products Page 1 www manuelectronics com au SETUP 1 The printer supplied by ManuFlo will have its serial port settings already configured as described on Page 8 If using another serial printer then check and if necessary adjust its serial port settings refer to the printer s User Manual 2 Ensure that power is off to the serial printer to the ME6008M and to your existing Batch Controllers from which the flowmeter signals will be obtained 3 Connect the supplied RS232 Communication Cable see Page 8 between the ME6008M s DB9 RS232 port and the DB25 port of the LX300 II or DP8340 serial printer or another serial printer 4 Parallel from the back of your existing Batch Controllers or ME2000 or flowmeters to connect O Volts and Pulse signals from flowmeters to the ME6008M see pages 3 and 4 IMPORTANT If using a paddlewheel type flowsensor then connect the flowsensor to either Channel 1 or to Channel 2 only of the ME6008M as these channels have specialised inputs for paddlewheel water measurement pulses 5 Connect power to
4. the ME6008M e if an ac powered unit then connect 240 vac mains power to the ME6008M e if a DC powered unit then connect 12 VDC power 6 Turn power on to the serial printer and to the ME6008M The printer online indicator will come on The ME6008M will show the power on screen for about 3 seconds then will show Screen 1 see the Menu Tree section on page 5 7 Ensure that the correct printer model is selected menu screen 11B This is usually pre configured by ManuFlo 8 Parameters including input pulse scaling are factory set to 1 pulse per unit L Parameters including pulse scaling can be reprogrammed to suit your specific installation see menus 10A and 10B e g if using 25mm MES25 admixture flowmeter set pulses unit to 0555 00 and units to Litres if using 50mm RPFS P water flowmeter set pulses unit to 0020 00 and units to Litres 9 Power up the Batch Controllers or ME2000 or flowmeters and perform normal batching operations At completion of each batch after a programmable delay time another record will print logging the batch IMPORTANT PRINT MODE For the ME6008M to automatically print out batch quantities the RUN key must be selected The unit is then in Count Mode Screen 2 on the Menu Tree diagram on Page 5 To Read Batch Log via a Personal Computer PC using the PC serial port To read the entire batch log via a PC e connect a communications cable see page 8 between the ME6008M serial port and the PC
5. C 2 Amps Optional 100 vac or 240 vac powered as from Aug 2015 Order Code ME6008M 8 channel Batch Monitor Printer Driver Unit 240 vac powered ME6008M 110 8 channel Batch Monitor Printer Driver Unit 110 vac powered ME6008M DC 8 channel Batch Monitor Printer Driver Unit 12 24 VDC powered FP RS232 port on front of ME6008M includes RS232 to USB converter cable in addition to the RS232 port at the back of ME6008M for easy access to download data to laptop LX300 II DP AC Due to continuous product improvement specifications are subject to change without notice rM 41 Carter Road Brookvale Mami 1071 Sydney NSW 2100 Australia Flow Measurement amp Control Products Ph 61 2 9905 4324 9938 1425 a division of l Fax 61 2 9938 5852 Web www manuelectronics com au Email sales manuelectronics com au MANU ELECTRONICS PTY LTD Page 9 Other ManuFlo Products Typical Batch Controller The entered quantity e g 50 L batching is automatically dispensed installation Simple Accurate Reliable thousands in use Available ex stock Water Storage Tank Solenoid ME995 7 Batch Controller RPFS P Paddlewheel Flow Sensor x H economical simple insertion flowmeter EE with a range of pipe adapters In various sizes and materials easy to clean for fresh or mild recycled water simple to use and calibrate set batch quantity via rotary dials z
6. CORE INDICATES WHICH DIGIT IS CURRENTLY SELECTED PRESS INC TO INCREMENT THE DIGIT CURRENTLY SELECTED PRESS SHF TO MOVE THE UNDERSCORE TO THE NEXT DIGIT PRESS NXT TO ENABLE A CHANGE OF THE TIME PRESS DNE TO SAVE DATE CHANGES AND RETURN TO SCREEN 1 SCREEN 12B ENTER THE TIME e THE UNDERSCORE INDICATES WHICH DIGIT IS CURRENTLY SELECTED PRESS INC TO INCREMENT THE DIGIT CURRENTLY SELECTED PRESS SHF TO MOVE THE UNDERSCORE TO THE NEXT DIGIT PRESS NXT TO ENABLE A CHANGE OF THE DATE PRESS DNE TO SAVE TIME CHANGES AND RETURN TO SCREEN 1 rm 41 Carter Road Brookvale Mami 1071 Sydney NSW 2100 Australia Flow Measurement amp Control Products Ph 61 2 9905 4324 9938 1425 aon Fax 61 2 9938 5852 MANU ELECTRONICS PTY LTD Web www manuelectronics com au Page 7 Email sales manuelectronics com au ME6008M DB25 Male DB9 Female DB9 Male DB9 Female 2 Transmit 2 x ER 2 Transmit 5 5 5 Serial Printer ME6008M logger Computer ME6008M logger RS232 Communication Cable RS232 Communication Cable ME6008M to Printer ME6008M to Computer via back serial port usually via ME6008M s front serial port but can use the back serial port after disconnecting printer The serial port of the attached printer or PC terminal must be set to the following p emm omamis 5 Printer Serial Port Settings ME6008M Pulses Per Unit setting toprintLitres toprintmls 0075 00 0000 08 0046 00 0000 05 0030 00 0000 03 Pul
7. D TOTALS e PRESS PRT TO ENABLE PRINTING e PRESS NXT TO DISPLAY THE NEXT CHANNELS GRAND TOTAL e PRESS RST TO CLEAR EITHER THE GRAND TOTALS OR BATCH HISTORY e PRESS DNE TO RETURN TO THE PREVIOUS SCREEN SCREEN 5 PRINT FLOW HISTORY e PRESS LST TO PRINT THE LAST BATCH RECORDED e PRESS ALL TO PRINT THE TOTAL BATCH HISTORY RECORDED e PRESS SUM TO PRINT THE GRAND TOTALS e PRESS DNE TO RETURN TO SCREEN 1 SCREEN 6A RESET GRAND TOTALS e PRESS YES TO RESET THE GRAND TOTALS e PRESS NXT TO RESET THE BATCH HISTORY e PRESS DNE TO RETURN TO SCREEN 1 SCREEN 6B RESET BATCH HISTORY e PRESS YES TO RESET THE BATCH HISTORY e PRESS NXT TO RESET THE GRAND TOTALS e PRESS DNE TO RETURN TO SCREEN 1 SCREEN 7 CONFIGURE THE BATCH MONITOR e PRESS BAT TO ENTER THE NEXT BATCH NUMBER REQUIRED e PRESS FLW TO ENTER THE K FACTORS FOR EACH CHANNEL e PRESS PRS TO ENTER THE PRINT DELAY OR PRINTER MODEL e PRESS TME TO ENTER THE DATE OR TIME rm 41 Carter Road Brookvale Mami Tenn Sydney NSW 2100 Australia Flow Measurement amp Control Products Ph 4 61 2 9905 4324 9938 1425 aon Fax 61 2 9938 5852 MANU ELECTRONICS PTY LTD Web www manuelectronics com au Page 6 Email sales manuelectronics com au ME6008M SCREEN 8 ENTER BATCH NUMBER e THE UNDERSCORE INDICATES WHICH DIGIT IS CURRENTLY SELECTED e PRESS INC TO INCREMENT THE DIGIT CURRENTLY SELECTED e PRESS SHF TO MOVE THE UNDERSCORE TO THE NEXT DIGIT e PRESS DNE TO RETURN T
8. ME6008M Batch Monitor Printer Driver Unit FEATURES e Prints QA batch totals automatically programmable delay or manually e Internally logs 500 batch events downloadable to your laptop PC via optional front access DB9 RS232 connector that also comes with a RS232 to USB adapter e Monitors up to 8 channels of water and admixture e Channel units in millilitres or Litres Revised Software e Batch number ID time and date e Real time clock e Grand Totals and batch history can also be printed or dumped to a PC on demand e User friendly menu tree e Programmable pulse scaling K Factor e P65 rated touchpad The Manu Electronics ME6008M has been designed to interface from Batch Controllers to loggers or serial printers and will provide automatic end of batch printing and datalogging of 500 batch events All records are time stamped from the units Real Time Clock The unit is operated from a front panel keypad with a LCD 2 line display Selections are made from a four function soft key tree structured menu SAMPLE PRINTOUTS ME6008M Batch Monitor Printer Driver WIDE COMPACT dot matrix tractor feed dot matrix paper roll X300 1l printer DP8340 printer 204mm wide printout 84mm wide printout 80 characters 40 characters l or USB connection Y to your DATE TIME CH 1 CH 2 CH 3 CH 4 CH S CH 6 CH 7 cis RAT N w AUAM ones CH CH 5 CH 6 CH 7 C H B L L mL mL mL
9. O SCREEN 1 SCREEN 9 CHANGE FLOW SETTINGS OR K FACTOR e PRESS SET TO SET THE K FACTOR FOR EACH CHANNEL see Table 2 on Page 8 e PRESS DNE TO RETURN TO SCREEN 1 SCREEN 10A ENTER THE K FACTOR FOR EACH CHANNEL e THE UNDERSCORE INDICATES WHICH DIGIT IS CURRENTLY SELECTED PRESS INC TO INCREMENT THE DIGIT CURRENTLY SELECTED PRESS SHF TO MOVE THE UNDERSCORE TO THE NEXT DIGIT PRESS NXT TO SELECT CHANNEL UNIT L or mL PRESS DNE TO RETURN TO SCREEN 1 SCREEN 10B ENTER THE UNIT FOR EACH CHANNEL PRESS INC TO SELECT L Litres or mL milliliters e PRESS NXT TO GO TO THE NEXT CHANNEL e PRESS DNE TO RETURN TO SCREEN 1 SCREEN 10C PULSE THRESHOLD BEFORE PRINTING A BATCH default is 40 pulses e PRESS INC TO INCREMENT THE DIGIT CURRENTLY SELECTED e PRESS SHF TO MOVE THE UNDERSCORE TO THE NEXT DIGIT e PRESS NXT TO GO TO THE NEXT CHANNEL e PRESS DNE TO RETURN TO SCREEN 1 SCREEN 11A ENTER THE PRINT DELAY THE PRINT DELAY IS THE TIME OF INACTIVITY ON ALL CHANNELS THAT INDICATES THE END OF A BATCH IT CAN BE SET FROM 2 TO 99 SECONDS PRESS INC TO INCREMENT THE DIGIT CURRENTLY SELECTED PRESS SHF TO MOVE THE UNDERSCORE TO THE NEXT DIGIT PRESS NXT TO ENTER PRT PRINTER MODEL PRESS DNE TO RETURN TO SCREEN 1 SCREEN 11B ENTER THE PRINTER MODEL e PRESS INC TO SELECT EITHER THE LX300 I OR THE DP8340 PRINTER e PRESS NXT TO RETURN TO SCREEN 114A e PRESS DNE TO RETURN TO SCREEN 1 SCREEN 12A ENTER THE DATE e THE UNDERS
10. s to screen 1 MENU TREE SCREEN 1 SCREEN 0 BATCH MONITOR MANU ELECTRONICS RUN SHW SET ME6008M V2 3 A B C D A B C D SCREEN4 CH01 000000 PRT NXT RST DNE A B C D to screen 1 SCREEN 6A RESET GRAND TOT YES NXT DNE SCREEN 5 PRINT FLOW HIST LST ALL SUM DNE D A B C D to screen 1 to screen 1 SCREEN 6B RESET BATCH HIS YES NXT DNE D SCREEN 7 to screen 1 29 05 11 08 56 BAT FLW PRS TME A B C D SCREEN 11A PRINT DELAY 02S INC SHF NXT DNE A B C D SCREEN 12A DATE 29 05 11 INC SHF NXT DNE A B C D to screen 1 to screen 1 SCREEN 11B SCREEN 12B PRT LX300 TIME 08 56 47 INC NXT DNE INC SHF NXT DNE A B C D A B C D to screen 1 to screen 1 a division of MANU ELECTRONICS PTY LTD Page 5 www manuelectronics com au ME6008M OPERATING INSTRUCTIONS SCREEN 0 POWER ON SCREEN e LASTS APPROXIMATELY 3 SECONDS GIVES CURRENT FIRMWARE VERSION SCREEN 1 MAIN MENU e PRESS RUN TO ENABLE COUNTING TO COMMENCE e PRESS SHW TO DISPLAY THE CURRENT GRAND TOTALS FOR EACH CHANNEL e PRESS SET TO CONFIGURE THE BATCH MONITOR SCREEN 2 COUNT MODE e PRESS PRT TO PRINT THE CURRENT BATCH DATA e PRESS NXT TO DISPLAY THE NEXT CHANNEL e PRESS RST TO CLEAR THE CURRENT BATCH DATA e PRESS DNE TO RETURN TO THE PREVIOUS SCREEN SCREEN 3 CLEAR BATCH e PRESS YES TO CLEAR THE CURRENT BATCH DATA ONLY e PRESS DNE TO RETURN TO THE PREVIOUS SCREEN SCREEN 4 SHOW CURRENT GRAN
11. s port using the serial to USB adapter if necessary e start HyperTerminal software on the PC HyperTerminal is supplied as a part of Windows up to Windows XP or can be downloaded from the Internet at sites such as http www hilgraeve com hyperterminal trial http hyperterminal private edition findmysoft com http download cnet com HyperTerminal Private Edition 3000 2155 4 10966768 html e ensure the PC s serial port settings are as described page 8 e ensure printer is switched off to avoid the event log also printing out on the printer On the ME6008M go to Screen 5 PRINT FLOW HIST see page 5 and press ALL and the ME6008M will dump the batch log to the PC MSM RS Rdvsd s NCSENUD MGM O MANU ELECTRONICS PTY LTD Flow Measurement amp Control Products Page 2 www manuelectronics com au CONNECTION DIAGRAM TO MANUFLO BATCH CONTROLLERS c 3S Ifid PULSE SHIELD ME H H FLOWMETER 2 L AS 1Nd SHIELD The flowmeter PULSE and 0 V are parallelled from the back of the Batch Controllers to the ME6008M SHIELDED CABLE EARTHED EY SS Se a s O Jl FLOWMETER 1 RS232 V DB9 Female AN DB25 Male UNITS TENS HUNDREDS 6 6 6 P M ee E EE gt lt C2 Re TT3IHS O ZO ria 5 Qo T A c o 4 CN LLI Lu Zw i ao Manu o TM a division of gt MANU ELECTRONICS PTY LTD Flow Measurement amp Control Products Page 3 www manuelectronics com au
12. ses Litre 19 46 l RPFS P 25mm RPFS P 32m RPFS P 40mm 20 1000 555 0001 00 0 1 0000 10 Pulses Per Unit settings ammi AA a NA 0020 00 0000 02 1000 0001 00 0555 00 0000 56 Notes e To avoid possible noise causing bad records there is a default threshold of 40 pulses before a batch is logged rM 41 Carter Road Brookvale Mami 1071 Sydney NSW 2100 Australia Flow Measurement amp Control Products Ph 61 2 9905 4324 9938 1425 a division of l Fax 61 2 9938 5852 Web www manuelectronics com au Email sales manuelectronics com au MANU ELECTRONICS PTY LTD Page 8 ME6008M TECHNICAL SPECIFICATIONS ME6008M Printer Driver Unit 8 Channels 1 amp 2 will accept ManuFlo RPFS P oaddlewheel sensors or NAMUR sensors 1 5 kHz each channel 500 batches circular buffer Optional RS232 to USB adapter TECHNICAL SPECIFICATIONS PRINTERS LX300 II Printer DP8340 Printer Type Narrow carriage dot matrix impact printer Dot matrix printer 9 pins 80 columns 9 pins 40 columns 115mm paper width Paper feed Continuous friction 1x Serial set to 9600 baud 1x Parallel 1x Serial set to 9600 baud 8kb buffer 1 5 kb buffer 337cps high speed draft 12cpi 2 lines per second bi directional 270cps draft 12cpi 67cps NLQ 912cpi 366 w x 275 d x 159 h mm 202 w x 200 d x 98 h mm 1 9 kg 49kg 0 00 0 00 O Power supply 240vac powered otandard 12 VD