1. e Run Frame run number and frame number of the current frame read e GPS Time Size GPS time and size bytes of the current frame read e UTC date GPS time in explicit UTC date format of the current frame read e SetRefPlots To save on disk a ROOT file that contain the current plots made e GetRefPlots To superpose on the current plots the Reference plots saved in a ROOT file e EditRefPlots To manage for instance change color of the reference plots avail able in memory e Data Source the current frames source file directory or a process accessed through the network The first message on this line is Give me input data e Start Start the data display It creates the configuration file a siesta cards file dd car and starts a Siesta like job interactive with the data display GUI e Stop Stop the read of data A file dd hsto containing the plot is created e Pause Pause the read of data e Next Refresh Continue to read data up to the next plot refresh e Continue Continue to read data e Next Frame Continue to read data up to the next frame e Slider bar Run across the X axis for all the plots last zoomed on X axis e Options Provides access to the Options panel e Debug Provides access to the Debug panel e Help Check this button to get a short information about the dataDisplay e Help Ballons Check this button to get online information about each button browser or input fie
2. TRFCT COHE or CORR button the selected channels are taken 2 by 2 from upper to lower If a channel is pending it is taken as Y variable and the data display will take as X variable the channel you select just after e Plots this browser shows the list of plots created You can select one or several plots and edit or remove them e Save this button allows to save the current plots according to the suffix you put in the name root ps or jpg e Edit this button allows to change the parameters of the plots selected e Edit Clone this button do the same as Edit but the parameters you changed are cloned to all the plots of the same type as the one you edited This is convenient when you want to change for instance the time window size of all the time plots e Edit All this button do the same as Edit but the parameters you changed are cloned to all the plots This is convenient when you want to change for instance the time window size or the resampling frequency of all the plots e Superpose this button put together in the same root pad the plots selected e Unsuperpose this button separate put in different root pad the plots selected e Copy create new plots by doing a copy of the plots selected e Transform transform the selected plots into another type of plots with default values and same channels e PermuteVar this button exchange the variables of the 2D TRFCT or COHE plots selected
3. Edit Cancel Cancel all the changes you made VIRGO Date April 29 2009 Page 32 2 25 9 General informations about the plots e Time plot In the time plots a blue vertical line is present each time at least one frame is missing a green vertical line is present each time the channel is missing a red line is present each time a data sample is corrupted NaN etc e FFT plot Units on the vertical axis are channel units sqrt Hz e 2D plot When title of the plot is varl_vs_var2 it means that varl is on the vertical axis and var2 on the horizontal axis e TrFct plot When title of the plot is varl_over_var2 it means that the Transfert Function plot is FFT varl FFT var2 e Cohe plot When title of the plot is varl_vs_var2 it means that the Coherence Function plot is FFT varl conj var2 FFT var1 FFT var2 2 26 User Functions Panel In this panel you can create or load a C or C function that will be then available in the USER FCT menu of the Data and Plots panel A help button gives you some example on how to write such a function and what is not possible to write currently The list of created or loaded functions are displayed in the browser You can select one of them and compile it But it will be automatically compiled as soon as you need it to do operations on the channels 2 27 Dump Panel In this panel the right browser shows the list of channels that will be dumped on the
4. This button provides a menu Each item of this menu allows to select a source of trigger condition Each time a trigger condition is verified the dataDisplay compute the plots and shows them otherwise the plots are not computed For instance a FFT can be computed with the condition that Qc_Moni_ScienceMode 1 Trigger from channels you can define a list of conditions on channels value using the AND operator For instance Qc_Moni_ScienceMode 1 AND Pr_B5_DC 0 001 AND outlierMoni_Pr_B1_ACp 6 Trigger from ASCII file you provide the name of a file that contains a list of start GPS and duration or Start GPS and Stop GPS Then the dataDisplay will read data only in those time segments Trigger from FrEvent you provide the name of an FrEvent channel and a condition For instance gt EVENT_SNR 10 Then dataDisplay will search for frames where this condition is verified and will compute plots only with those frames 2 24 2 The plots browsers and buttons Clicking on one of those buttons creates a plot if at least one data channel was selected e TIME A time plot of each selected channel is created e CORR A correlation plot between var2 and varl is created e FFT A spectrum plot of each selected channel is created VIRGO Date April 29 2009 Page 21 Save Plots EditClone USER FCT TRIGGER Update Channels Remove Deni i ta pes Crm Steen k pes Move Downl ea
5. Time Window number of seconds of data that are displayed in the time plot Sampling Freq The new frequency at which you resample the data in order to view at larger scales the time evolution This field contains by default the initial sampling frequency of the channel Time Shift Percentage of the time window used to shift the time plot visualization Number of FFT to average number of spectra you average Visualization is done each time you add a spectrum so you can see the progression of the averaging Refresh Period in number of FFTs the refresh of the plot s display is done every time this number of FFTs has been computed Zoom freq min Minimal frequency just for visualization no cut in frequency is really done Zoom freq min Minimal frequency just for visualization no frequency cut is really done Zoom freq max Maximal frequency just for visualization logx on off button to set log scale on horizontal axis VIRGO Date April 29 2009 Page 25 logy on off button to set log scale on vertical axis gridx on off button to set grid lines along horizontal axis gridy on off button to set grid lines along vertical axis autoY on off button to set automatically the right vertical edges unitsY on off button to set right units on the vertical axis noDC on off button to set removal of mean value DC component of the signal 1 Hz on off button to set vertical axis in 1 Hz units instead of 1 sqrt Hz rms
6. e Fixed bug in the better management of missing frames in the TIME plots e Fixed some bugs in the trigger functionality but not yet fully tested e Button TRIGGER on mainbrowser panel now provides three choices Trigger from channels you set a condition on some channels values Then the plots are updated only with data taken in the segments defined by this condition Trigger from Ascii File you provide the name of a file that contains a list of event s GPS times Then the plots will show only the data of the frames that contain those events An automatic Pause is done by default between each event display Trigger from Event you provide the name of a FrEvent see in the procData browser all the names that begin with EVENT and a threshold for instance EVENT _SNR 0 Then the plots will show only the data of the frames where the amplitude of the events is over the threshold An automatic Pause is done by default between each event display 2 10 Bug fixes and new functionalities between v9r09p2 and v9r10 e Coherence or Transfert functions between signals of different frequencies were done by resampling first the highest frequency signal This could introduce aliasing Now the lowest frequency signal is oversampled but the plot is shown only on its meaningful part below the lowest frequency 2 VIRGO Date April 29 2009 Page 9 e Now output signal resulting from an operation on input channels User F
7. on off button to superpose the rms integrate FFT starting from Nyquist frequency on the FFT plot decay The averaging of FFTs uses a moving average Default Put the default values for all the fields or on off buttons OK Acknowledge the changes you made Those changes will affect all the plots of the same type if you used Edit Clone instead of Edit Cancel Cancel all the changes you made 2 25 3 Edit panel of FFTTIME plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards Time Window for Time Freq plot number of seconds of data that are displayed in the time frequency plot Frequency resolution Hz bin width on Y axis or the inverse of the number of seconds over which each FFT is computed Time resolution s bin width on X axis or number of seconds of data between two consecutive averaged FFT computed Sampling Freq The new frequency at which you resample the data in order to view at larger scales the time evolution This field contains by default the initial sampling frequency of the channel Time Shift Percentage of the FFT time window used to shift in time before computing next FFT refresh Period Percentage of the time window used to shift along time horizontal axis the time frequency plot visualization Zoom freq min Minimal frequency just for visualization VIRGO Date April 29 2009
8. this documentation and some gif pictures showing dataDisplay data Display package uses ANSI C language compiled with cc and cxx under Unix OSF1 v5 alpha workstations platforms and gcc under Linux platforms It has been compiled under OSF1 v4 or v5 under Linux RedHat 7 or 9 SL4 and under Cygwin so can be used within Windows environment It is based on the Xforms library for the GUI on the Frame library for the data man agement and on the ROOT library for the plots display The installation of dataDisplay needs at least e Xforms library virgoApp Xform 2 e ROOT library virgoApp root 4 e Frame library virgoApp Fr 5 For an online use of the dataDisplay you need also e CSet package virgoApp CSet 6 e Cm package virgoApp Cm 7 For more informations about the packages used you can have a look at the Web page http wwwcascina virgo infn it sDoc Some modified source code of the siesta package 3 is also used The source files are in the directory mysiesta URPlot c replace UHistoL c UFrameL c UJobL c UArrayL c UMathL c USignalL c and their header files and c_hbook h There are two global structures defined in dataDisplay h DyTool and DyPlots and an external structure for each Xforms panel see header files in src xform directory 3 2 Compilation scripts in directory mgr In mgr directory Makefiles dedicated to specific platforms are available e Makefile VIRGO osf1 crx6 compile under O
9. 4 Pr_B1_ACp over Pr_B5_DC_TRFCT 2 e Iso 0 2 ER la lso 5 100 la 0 1 L RAS x Ji 000 o T 20 1 10 w 10 y ey A i mieron z are 59620521 304 Mar22 2007 17 41 47 UTC at0 81926nAvAS gsg620811 204 Ma orari sere deo st9tendeyse 858620520 Mar 22 2007 17 41 46 UTC dt 60s 858620523 Mar 22 2007 17 41 49 UTC dt 1s nAv 1 Figure 1 Example of plots made by the Virgo Data Display 2 User s Manual 2 1 Starting dataDisplay Command is just dataDisplay once you got the Virgo environment When starting dataDisplay you can provide optional arguments VIRGO Date April 29 2009 Page 4 Usage dataDisplay config f start GPS 1 duration o filename t title b q h noplot debug dbglv config name of a configuration file f next argument must be a GPS time in seconds for instance 894368450 or an UTC date between quotes for instance 9 May 2008 13 40 36 1 next argument is the duration in seconds of data to be read o next argument must be with extension jpg or root or eps t next argument is the title that will appear on top of the plots canvas b run in background mode without displaying plots but producing a jpg file q quit when stop is pressed or when all the required frames have been read h to get the help message f followed by the GPS time where to start reading data 1 followed by the number of seconds of data to read o followed by the name of the
10. Page 26 Time Frequency Plot I Figure 5 The FFTTIME plot edit panel e Zoom freq max Maximal frequency just for visualization e Zmin Z value min threshold used for color scale e Zmax Z value max threshold used for color scale e logx on off button to set log scale on horizontal axis e logy on off button to set log scale on vertical axis e logz on off button to set log scale on colors axis e gridx on off button to set grid lines along horizontal axis e gridy on off button to set grid lines along vertical axis e gridz on off button to set log scale on colors axis e autoZ on off button to set automatic computation of min and max on Z axis e unitsZ on off button to set right units on the colors axis e noDC on off button to set removal of mean value DC component of the signal VIRGO Date April 29 2009 Page 27 decay The averaging of FFTs uses a moving average Default Put the default values for all the fields or on off buttons OK Acknowledge the changes you made Those changes will affect all the plots of the same type if you used Edit Clone instead of Edit Cancel Cancel all the changes you made 2 25 4 Edit panel of TRFCT or COHE plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards Time Window number of seconds of data that are displayed in the time plot Sa
11. Suppose you would like to look at the Spectrum of a microphone signal Data are under frame format in a file toto dat First in the main panel select the item Read File of Input Menu Then a Xforms predefined browser will ask you to select the file you want to read The main browser panel is then displayed You see in it a list of channels in the adc browser Select the channel corresponding to the microphone and push the button FFT The plot is made with default parameters as you can verify in the white bottom status line of the main panel If you trust the default parameters just push Start to read the frames and get the FFT plot If you prefer to check or change the parameters select your plot in the plots browser and push the button Edit A panel containing the name of the plot and its parameters is displayed Change the parameters as you want and push OK Then you can Start Once frames reading is finished or if you pushed the Stop button the FFT plot has been recorded under PAW format in the file dd hsto 2 29 2 Read frames online from files Suppose you would like to look at the FFT of a microphone signal Data are currently written under frame format as several frames per file in a directory totoDir You would like to look at the data while they are created First in the main panel select Read Files Online from Input Menu A browser is displayed where you can
12. and bias of the channels when getting data from the dataSender Added GPS time origin under the 2D plots Fixed bugs for RAW 1DTIME and RAWTIME plots for the units and for the automatic Y axis scale update Put character _ instead of characters in the title of a plot when the channel isa SMS data VIRGO Date April 29 2009 Page 12 Fixed many other small bugs like the one of button nColxnRow of mainbrowser panel 2 14 Bug fixes and new functionalities from v9r08 In addition to Fr Xforms and Root this dataDisplay needs only Cm and CSet to run online Default start GPS time indicates now the most recent available data minus one hour Default channels list is now made from the most recent available data minus one hour Added a blue button near the Start date UTC field in the mainpanel This button allows to get the now date 2 15 Bug fixes and new functionalities from v9r06 Possibility to UnZoom Y correctly all the plots superposed in the same Pad This is available by clicking with right button of the mouse on the Y axis Possibility to zoom the Labels on X or Y axis of all the plots This is available by clicking with right button of the mouse on the plot s axis Possibility to zoom the Legends of all the plots This is available by clicking with right button of the mouse on the plot s axis Possibility to multiply the plot by a scaling factor and to add an offset Th
13. code based on ROOT mainly the code in VDyPlot cc Plots building Debug information concerning all the data treatment and building of plots mainly the code in URPlot c Plots creation Debug information concerning all the creation and edition of the plots mainly the code in DyPlot c Inputs offline Debug information concerning all the data read from files mainly the code in DyFiles c Inputs online Debug information concerning all the data read online through Cm or shared memory mainly the code in DyFiles c DyCm c DyDd c Data read Debug information concerning all the frames read mainly the code in DyVar c DyFiles c UFrameL c Channels management Debug information concerning all the channels manage ment and the browsers of channels mainly the code in DyVar c DyXform c Configuration read write Debug information concerning all the configuration read and write mainly the code in DyConfig c VIRGO Date April 29 2009 Page 18 e Speed of read display Debug information concerning the time needed to read data or to display the plots mainly the code in URPlot c DyFiles c DyUtil c e See called functions Show the name of the functions where the dataDisplay is currently passing e Any other stuff Debug information concerning various parts mainly the GUI mainly the code in DyUtil c DyXform c dataDisplay c 2 22 Input Menu This menu allows you to select the source of the frames files or Cm server among th
14. e Move Up move up in the list all the plots selected e Move Down move down in the list all the plots selected e Hide this button puts in hide state all the plots selected This means that they are still available but will not be displayed e Show this button puts in show state all the plots selected This means that they will be displayed e Remove remove from the list all the plots selected e Clear remove all the plots from the list VIRGO Date April 29 2009 Page 23 Default Time Plot Figure 4 The TIME plot edit panel 2 25 The editing plot panels To edit a plot select it in the browser and click on Edit A panel is displayed where you can edit the various parameters and plot options depending on the plot s type For more help about it you can also use the Help Ballons button of the dataDisplay 2 25 1 Edit panel of TIME plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards Time Window number of seconds of data that are displayed in the time plot Sampling Freq The new frequency at which you resample the data in order to view at larger scales the time evolution This field contains by default the initial sampling frequency of the channel minmax If this button is selected the resampling is done by computing the min and max values over 2N sampling instead of co
15. left browser This list is increased by using the DUMP button of the Data and Plots panel Button Remove allows to remove some of them Button Clear removes all of them Button Full Frame replace the dump of channels by a dump of the full frame received The dump is done according to the dump level chosen The content of the left browser can be saved in a file by using the button Save Dump information is visible only after the button Start of the mainpanel has been pushed 2 28 Output Panel In this panel you can decide if you want to write on disk the frames received by the dataDisplay At any time you can start and stop writing by checking or not the button Write frames in file You can choose a tag that defines the list of channels that will be written on disk the name of the directory where will be written the frames and the number of frames per file If the directory does not exist it will be created at first frame s writing The maximum number of bytes that you can write within a dataDisplay session is 10 GB Writing of data is done as soon as the Start button of the mainpanel is VIRGO Date April 29 2009 Page 33 pushed even if no plot is shown If some plots are shown the corresponding channels are automatically included in the data written on disk VIRGO Date April 29 2009 Page 34 2 29 Five typical uses of the data Display 2 29 1 Read frames offline from a file
16. name of the producer of the shared memory to which you connect e Read Directory Take data from all the files in a directory Just select one file of the directory you want to add e Read Files Online Take data from a directory where frames are currently written in files There is a condition for using this option all the files in the directory must have the same generic name containing an incremented number When asked just select one file of the directory you want to add e Read Wave Files Take data from audio wave files In this case only one channel named fraudio is created VIRGO Date April 29 2009 Page 19 e Use fixed Cm Name Declare the data Display to the Cm Name Server If you select this menu item you are asked for a Cm name default is your login name or the last Cm Name used e Files List It opens a panel showing the list of input files that have been selected up to now and that are going to be read by the data Display once button Start has been pushed 2 23 Configurations Menu In this menu you can Load a configuration Save the present configuration with the name previously used or Save as the present configuration using an other name Each configuration file produced by the data Display is a car Siesta cards file Each time you push the Start button the current configuration is automatically saved in a file dd car This is independant of what you do with the Con
17. output jpg file noplot plots are not displayed while running but a jpg is produced at the end debug followed by the level of debug If config is provided dataDisplay creates its dd car file and starts immediately to read frames according to the configuration provided Each time the button Start is pushed a configuration file dd car is created in the directory where the dataDisplay was started If you do not have write permission in this directory dd car is written in your home directory 2 2 To be done in a next version Replace by in the Slow Monitoring channels names Fix the bug of one additional second of missing frames on TIME plots when receiv ing frames from a dataSender In the menu of Read Files do not interpret a link to a directory as a file when we click on it Better test the TRIGGER functionality and simplify the user interface especially for triggers lists in ASCII files Add an anti alias filtering when dataDisplay resamples the data VIRGO Date April 29 2009 2 3 2 4 Page 5 Put in USER FCT and TRIGGER the possibility to use home made functions mean rms brms filters Improve the way FFT of derivative or primitive is currently done Replace the siesta type main loop by a FdIO type main loop This would simplify the management of the plots especially the superposition of signals with different sampling frequencies Do the Draw of the plots only once for al
18. select any file of the directory totoDir The main browser panel is then displayed You see in it a list of channels in the adc browser Select the adc corresponding to the microphone and push the button FFT The plot is made with default parameters as you can verify in the white bottom status line of the main panel If you trust the default parameters just push Start to read the frames and get the FFT plot The data Display will read the last frame of the files already present in the directory and will wait for the next file to be written in this directory until you push the Stop button For now the data display is only able to read online files whose name is made of a generic name with an incremented number in it for instance FR12 dat FR22 dat FR32 dat or myframe_43 myframe_44 2 29 3 Read frames online from a Cm server Suppose you would like to get frames from a Cm server a Frame Builder for instance Choose Connect to a Cm Server in the Input Menu Select one Cm server in the list presented and double click or click on OK Then list of channels is get or one frame is read and the Data and Plots panel should show the list of available channels Then once you created your plots push the Start button You should normally get frames from the Cm server and view the desired plots online 2 29 4 Read frames online from a shared memory Suppose you wou
19. to do the link under Cygwin 3 4 The main functions and structures This data Display package uses two global C structures DyTool and DyPlot pointed respectively by the pointers Dy and Plot i e DyTool It contains general parameters useful for most of the data display func tions For instance Dy gt Order is the status of the data Display Stop Pause Start Each parameter of this structure is described in the header file dataDis play h e DyPlot It contains the parameters of each plot one DyPlot structure per plot pointed by Plot i Each parameter of this structure is described in the header file dataDisplay h The two previous structures are used in almost all the functions Here is a non exhaustive list of the data display functions still to be updated e main Arguments can be passed to this function the name of the configuration file the number of frames to read and the debug level In function main the Xform library is initialized Rest of the initialization is done by the function DylInit the panels are set and the main panel is displayed before entering the infinite fi do_forms GUI events loop VIRGO Date April 29 2009 Page 38 e DyReadFirstFrame It reads a first frame of the files list or from the Cm server and uses it to build the variables lists of the Data and Plots panel This function is called each time you get a new configuration Config Menu or a new source of frames In
20. CNRS INFN Centre Nationale de la Recherche Scientifique Istituto Nazionale di Fisica Nucleare MJIN IRG VIRGO Data Display Users s Manual D Verkindt D Buskulic LAPP phone 00 334 50 09 16 00 email verkindt lapp in2p3 fr VIR 008A 08 Version v9rl2p5 Date April 29 2009 VIRGO A joint CNRS INFN Project Project Office INFN Sezione di Pisa Via Livornese 1291 56010 San Piero a Grado Pisa Italia Secretariat Telephone 39 50 880 327 or 880 352 FAX 39 50 880 350 e mail virgo pisa infn it VIRGO Date April 29 2009 Page 1 Contents 1 Introduction 3 2 User s Manual 3 2 1 Starting databisplay ou 3s 42 da e ale ad eee 3 2 2 To be done in a next version hoe A ea i e la 4 2 3 Bug fixes and new functionalities between v9r12p4 and v9r12p5 5 2 4 Bug fixes and new functionalities between v9r12p3 and v9r12p4 5 2 5 Bug fixes and new functionalities between v9r12p2 and v9r12p3 6 2 6 Bug fixes and new functionalities between v9r11p5 and v9r12 or v9r12p1 OVIL ZDA lt q a a a ate aa Sk a aS BAR Bee Bw a 6 2 7 Bug fixes and new functionalities between v9r11p4 and v9rllp5 7 2 8 Bug fixes and new functionalities between v9rllp1 and v9rllp4 8 2 9 Bug fixes and new functionalities between v9r10 and v9rllpl 8 2 10 Bug fixes and new functionalities between v9r09p2 and v9rl10 8 2 11 Bug fixes and new functionalities between v9r09p1 and v9r09p2 9 2 12 Bug fixes and ne
21. D plot rsa eda 29 2 25 7 Edit panel of 1DTIME plot 30 2 25 8 Edit panel of 2D plot siena aree a re A Bl SO eR 31 2 25 9 General informations about the plots 32 ser Functions Panel a Sss s amp pniti poi G4 Oy e lee ele da 32 Dump Pamela eS agit ione eee 32 OQu tp t Panelen tac tat cst ae a a oe co oe RAI She A thd Pe ee i 32 Five typical uses of the data Display 2 34 2 29 1 Read frames offline from a file 34 2 29 2 Read frames online from files 34 2 29 3 Read frames online from a Cm server 0 34 2 29 4 Read frames online from a shared memory 34 2 29 5 Read frames from the dataSender 35 Developer s Manual 36 Overview and Installation ea lie he as at ders a ee DS 36 Compilation scripts in directory mgr 200 36 Compilation with CMT in directory cmt i sd wd eed aa ia 37 The main functions and structures 2 04 lle el ele a 37 Example of data display working steps oaoa aa a 39 VIRGO Date April 29 2009 Page 3 1 Introduction The output of the Virgo Online Acquisition is numerical data structured as Frames Those frames contain raw data for instance ADC values as well as processed data h values results of online monitoring or online analysis To view and plot such data the VIRGO experiment uses the dataDisplay software described in this note The data Display gives the possibility to dump data to hear the da
22. SF1 in Virgo environment VIRGO Date April 29 2009 Page 37 e Makefile LAPP linux egcs compile under RedHat Linux v7 or v9 or SL4 The command is for instance gmake f Makefile VIRGO osf1 cxx6 There are also Makefiles with suffix nocm like Makefile VIRGO osf1 cxx6_nocm They compile an offline version of the dataDisplay uses only Frame Root and Xforms libraries that take input frames only from files or shared memory All the Makefiles contain an include of the file Make macros which contains the com mon parts independant of the platform and an include of the file Make requirements which contains the maximal list of the needed packages The mgr directory contains also a script named makeUtil to compile any additional tool like sound2frame c provided in the Dy package 3 3 Compilation with CMT in directory cmt In cmt directory thanks to JM Teuler and F Carbognani an updated requirements file is available To use it you need to have installed first the CMT package or to be already in the Virgo standard software environment Under OSF1 or Linux just go into the cmt directory and do the command cmt config followed by the command gmake To compile under Cygwin you need first to uncomment some lines in the requirements file and to comment others see instructions in the requirements file A script named build_cygwin is also available in the cmt directory It case of problem it can used
23. al axis y nBin number of bins on vertical axis y min Minimal value of the plot on vertical axis y max Maximal value of the plot on vertical axis Shift n samplings shift in number of data samples between varX and varY varX can be identical to varY Refresh Period Number of seconds of data between two refreshes of the plot visualization stat on off button to get statistics number on the plot logx on off button to set log scale on horizontal axis logy on off button to set log scale on vertical axis logz on off button to set log scale on colors axis gridx on off button to set grid lines along horizontal axis gridy on off button to set grid lines along vertical axis gridz on off button to set grid lines along colors axis autoX on off button to have an automatic set of xmin xmax ymin and ymax while plotting the data unitsY on off button to set right units on the horizontal and vertical axis color on off button to use 2D plot with colors on third axis cont on off button to use 2D plot with colored contours on third axis lego on off button to use 3D plot with squares in each bin surf on off button to use 3D plot with interpolated surface scat on off button to use 2D plot with scattered points Default Put the default values for all the fields or on off buttons OK Acknowledge the changes you made Those changes will affect all the plots of the same type if you used Edit Clone instead of
24. alization Zoom freq min Minimal frequency just for visualization Zoom freq max Maximal frequency just for visualization Zmin Z value min threshold used for color scale Zmax Z value max threshold used for color scale logx on off button to set log scale on horizontal axis logy on off button to set log scale on vertical axis logz on off button to set log scale on colors axis gridx on off button to set grid lines along horizontal axis gridy on off button to set grid lines along vertical axis VIRGO Date April 29 2009 Page 29 gridz on off button to set log scale on colors axis autoZ on off button to set automatic computation of min and max on Z axis unitsZ on off button to set right units on the colors axis noDC on off button to set removal of mean value DC component of the signal decay The averaging of FFTs uses a moving average Default Put the default values for all the fields or on off buttons OK Acknowledge the changes you made Those changes will affect all the plots of the same type if you used Edit Clone instead of Edit Cancel Cancel all the changes you made 2 25 6 Edit panel of 1D plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards nBin number of seconds of data that are displayed in the time plot Refresh Period Number of seconds of data between two plot visu
25. alization re freshes x min Minimal value of the plot on horizontal axis x max Maximal value of the plot on horizontal axis logx on off button to set log scale on horizontal axis logy on off button to set log scale on vertical axis gridx on off button to set grid lines along horizontal axis gridy on off button to set grid lines along vertical axis stat on off button to get statistics number on the plot autoX on off button to have an automatic set of xmin and xmax while plotting the data unitsX on off button to set right units on the HORIZONTAL axis Default Put the default values for all the fields or on off buttons OK Acknowledge the changes you made Those changes will affect all the plots of the same type if you used Edit Clone instead of Edit Cancel Cancel all the changes you made VIRGO Date April 29 2009 Page 30 2 25 7 Edit panel of 1DTIME plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards Time Window number of seconds of data that are displayed in the 1d time plot Time Window for statistics number of seconds of data over which 1D distribu tion is done Sampling Freq The new frequency at which you resample the data in order to view at larger scales the time evolution This field contains by default the initial sampling frequency of the channel refresh Percent Per
26. cal line on the plot or when frame is absent blue vertical line the value under the colored line is not anymore 0 but is equal to the one of the previous bin Possibility to compute min and max over N samples instead of resampling over N samples For now only implemented in TIME plot Possibility to show plots only when a set of conditions on channels is fullfilled trigger functionality Implementation not yet finished 2 13 Bug fixes and new functionalities from v9r09 FFT Transfert Function and Coherence can now be computed with a running av erage button decay of the respective Edit panels Time frequency plot has a new Edit panel where parameters Time window for FFT computation and Number of FFTs to average have been replaced by time resolution and frequency resolution Two new buttons in the mainpanel SetRefPlots allows to save in a file the current plots as reference plots for a later usage and GetRefPlots allows to superpose the reference plots to the current plots In case of plots FFTTIME 1DTIME and RAWTIME or RAW in two dimensions camera images superposition of plots is replaced by the difference between current plot and reference plot Bug fixed in the last updated of a time plot when refresh period was over 50 In URPlot c added xxxIniFrame functions that do initialization for each plot when a first frame is read This fix the bug of not receiving the units slope
27. centage of the time window used to shift along time hori zontal axis the time frequency plot visualization nBin Number of bins of the 1D distribution each vertical line of the plot Min Minimal value of the y axis if autoY not selected Max Maximal value of the y axis if autoY not selected Z max Z value threshold used for color scale logx on off button to set log scale on horizontal axis logy on off button to set log scale on vertical axis logz on off button to set log scale on colors axis gridx on off button to set grid lines along horizontal axis gridy on off button to set grid lines along vertical axis gridz on off button to set log scale on colors axis noDC on off button to set removal of mean value DC component of the signal unitsY on off button to set right units on the Y axis Default Put the default values for all the fields or on off buttons OK Acknowledge the changes you made Those changes will affect all the plots of the same type if you used Edit Clone instead of Edit Cancel Cancel all the changes you made VIRGO Date April 29 2009 Page 31 2 25 8 Edit panel of 2D plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards x nBin number of bins on horizontal axis x min Minimal value of the plot on horizontal axis x max Maximal value of the plot on horizont
28. ct menu are associated to different objects totol 2 3 of the same class toto e Slow Monitoring channels can now be used as inputs of Operations on channels User Fct menu e Result of an Operation on input channels can be a logical one For instance Pr_B1_ACp lt 0 01 AND Pr_B5_DC gt 0 15 OR Qc_Moni_ScienceMode gt 1 e A better management of missing frames in the TIME plots e An option cohe2D in the Coherence plots editing panel allows to show a 2D plot with all the coherence coefficients This allows to see cross coherence between different frequency domains e Some bugs fixed in the edition of plots e fixed bugs in the automatic plots changes when changing of input data raw 50Hz trend e Resampling of data can now be done in the 1D plot e A button color2D has been added in the main panel It allows to choose among 6 dif ferent color palettes for the 2D FFTTIME RAW cameras images COHETIME TRFCTTIME 1DTIME plots e Pause and Continue buttons can now be used when connected to the dataSender e A Trigger can be defined Button TRIGGER on mainbrowser panel It can be used button Trigger pushed on mainpanel and optionally there is an automatic Pause of the dataDisplay at each event encountered This TRIGGER still needs some tests 2 11 Bug fixes and new functionalities between v9r09p1 and v9r09p2 e Fixed wrong use of DyDecodeVar in DyFiles c e Connection to a shared memory is now based on Fd v5r0 co
29. de see DyFdShm c e Fixed a bug in DyGetDefaultFromPlot function of DyPlot c e Fixed a bug in conversion of date to GPS time month name without upper case was not seen e Now the plots configuration nColumns x nRow is saved into the configuration dd car VIRGO Date April 29 2009 Page 10 2 12 Bug fixes and new functionalities between v9r09 and v9r09p1 e No more file dd root saved on disk e Button Save near plots browser saves now in a Root file only the displayed plots e Time delay reduced between pushing the Stop button and beginning to work on the plots e No possibility now to select two ffl files or a ffl and a frames file So no more crashes when changing input data source e Possibility to superpose plots with different sampling frequencies e No more time axis problem when resampling trend data at low frequencies e GPS time shown under plots is now correct when using online connection e Possibility to visualize SMS data even if their sampling frequency is lower than frame frequency e Possibility to visualize data even if they are resampled at a frequency lower than frame frequency e Automatic update of plots parameters when changing the startGPS time e Automatic update of plots and channels names when changing data source type raw data 50Hz trend data e Automatic deselect of channels or plots in the browsers when button Auto deselect is activated e Default parameters of a new
30. e following options e Read FFL Take a set of ffl files frame files list as frames source A file selector allows you to select several files in a raw to search in directories first line and to put a tag on the files names second line Default tag is in this case ffl Each time you select this type of source the files are added to an internal list of files that you can view and modify using the option File List of this Input Menu e Read File Take a set of files as frames source A file selector allows you to select several files in a raw to search in directories first line and to put a tag on the files names second line Each time you select this type of source the files are added to an internal list of files that you can view and modify using the option File List of this Input Menu e Connect Online Take data online from a Cm server If you select this menu item you get the list of Cm servers available and you must choose one of them e Connect to DataSender Take data online from a dataSender If you select this menu item you get a panel with by default a connection to the Cascina dataSender You can then choose to connect to an other dataSender or choose the file you want to read through the dataSender Clicking on a directory allows you to see its content e Read Shared Memory Take data from a shared memory If you select this menu item you get an input field where you must provide the
31. ef plots button in the options panel Added a panel to manage the reference plots files available in memory and get them from files Improved the SuperposeExternalPlot feature available when right clicking on a plot s line VIRGO Date April 29 2009 Page 7 Added a RemoveRefPlot feature in the menu available when right clicking on a plot s line Added possibility to Hide temporarily some plots Hide button next to plots browser Added in Options panel the possibility to logx and logy on all plots to change size of legends stat boxes titles time strings axis labels on all the plots Fixed bugs in the automatic update when changing of input file data type raw 50Hz or trend data Use of the CIXFSelector selector of files also for Load Config and Get Reference Plot Added a cursor bar in the mainpanel to move along data in the last zoomed plot Added a button Transform in the mainbrowser panel that allows to change a plot from one type to an other Fixed a bug in RAWTIME plots default parameters Added channels names on the axis label of plot 2D Delete the unused plots still in memory after each Stop Improved and simplified the audio output capability soundSim in URPlot c Added possibility to take also wav audio files as input data Added in the Dy package a utility sound2frame that converts wav audio files into frames files and vice versa Improved the deb
32. es will affect all the plots of the same type if you used Edit Clone instead of Edit Cancel Cancel all the changes you made 2 25 5 Edit panel of TRFCTTIME or COHETIME plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards Time Window for Time Freq plot number of seconds of data that are displayed in the time frequency plot Frequency resolution Hz bin width on Y axis or the inverse of the number of seconds over which each FFT is computed Time resolution s bin width on X axis or number of seconds of data between two consecutive averaged FFT computed Sampling Freq The new frequency at which you resample the data in order to view at larger scales the time evolution This field contains by default the initial sampling frequency of the channel Time Shift Percentage of the FFT time window used to shift in time before computing next FFT Number of FFT to average number of spectra you average to produce one time slice of the time frequency plot Visualization is done each time a time slice is ready average computed Take care if you choose for instance 10 the value real time window for plot visualization will be 10 times the value you put in the field Time window for Time Freq plot refresh Period Percentage of the time window used to shift along time horizontal axis the time frequency plot visu
33. f frames is slower but independent of any TOC failure Skip Missing Frames when selected missing frames in the data stream read are not searched nor displayed blue vertical lines by the dataDisplay VIRGO Date April 29 2009 Page 17 Plots not shown when selected this button allows to make all the plots without viewing them Once dataDisplay has been stopped resulting plots can be find as usual in the file dd hsto Persistant reference plots when selected the reference plots in memory are superposed to the plots displayed No vertical colored lines when selected no red green or blue vertical lines in the plots appear anymore to indicate corrupted or missing data Full white Canvas when selected All the canvas appears white like the pads Slower but nicer fonts when selected the fonts used in all the plots are Helvetica 62 instead of Times 22 Trigger ON when selected the trigger function defined in the data and plots panel is used to selected the segments of data to be displayed Pause when trigger when selected dataDisplay goes into Pause each time the trigger function defined in the data and plots panel has triggered 2 21 The debug panel Debug level level of debug information Checks Used only for debugging so only for developpers Close to this button a white square allows to set the debug level Plots drawing Debug information concerning all the drawing painting part of the
34. fig Menu items 2 24 Data and Plots This panel is the central part of the data Display It shows buttons and browsers to select some frame s channels and to create plots 2 24 1 The data browsers and buttons e Slow Monitoring Stations the list of slow monitoring stations sms contained in the frames Selecting one gives you the list of data channels it contains e SMS Data the list of channels of the selected sms You can select one or several of them and push a plot button TIME 1D FFT It will create a plot for each channel selected To deselect a channel click on it To deselect all the channels use the button deselect all A small input box under the browser allows you a fast search of a name in the browser e ADC Data the list of frame s adc channels You can select one or several of them and push a plot button TIME 1D FFT It will create a plot for each channel selected To deselect a channel click on it To deselect all the channels use the button deselect all A small input box under the browser allows you a fast search of a name in the browser e Processed Data the list of frame s proc channels This is were you can find any processed reconstructed data You can select one or several of them and push a plot button TIME 1D FFT It will create a plot for each channel selected To deselect a channel click on it To deselect all the channels use the button deselect all A
35. is is available by clicking with right button of the mouse on the plot or for TIME plots by providing the scale and oftset parameters in the edit panel Possibility to superpose on the plot a reference taken from an other ROOT file This is available by clicking with right button of the mouse on the plot Macros containing the user s operations on the signals are kept now in the configu ration file dd car and also copied in virgoData DyAlgo Possibility to do RAWTIME plots This is useful especially when reading data which are already computed spectra and doing quickly a spectrogram Possibility to get data from a dataSender which reads the data on disks and provide them to the dataDisplay through Internet Need to do the command cmdomain Cascina before starting the dataDisplay Bugs fixed in the use of the and buttons close to the plots browser Possibility to change the plots distributions in the ROOT Canvas button ColxRaw in the mainbrowser panel VIRGO Date April 29 2009 Page 13 Possibility to define a refresh period larger than the time window used to compute the FFT for Spectrum Transfert Function or Coherence Function 2 16 Bug fixes and new functionalities from v9r05 Possibility to Scale as last on Y axis of a plot Zoom Y as last but respecting the local scale of the plot Possibility to zoom the Stat box of all the plots Possibility to rescale a plot on Y axis menu scale when clicking
36. l or only just before the Canvas Update Bug fixes and new functionalities between v9r12p4 and v9r12p5 Use the frame format v8 and frame library v8r01 Fixed a time offset problem when reading trend data time axis was correctly offset but not the data contained by the plot Put a security against full frames received from a Cm server number of channels in frame received must always be lower than twice the number of plots Changed what is displayed by the coherence plot Now what is shown is the module instead of the module module Fixed a bug in the conversion of GPS to UTC used under the plots only visible when looking at data before 1st Jan 2009 Bug fixes and new functionalities between v9r12p3 and v9r12p4 Fixed a bug in the FFTOfPrimitive function of VDyPlot cc Put units of transfer function module in the right order and removed sqrt Hz Fixed a bug in the zmin zmax of the 2D RAW plots camera images Added an option to square the plots useful to have the right dimensions of camera images Fixed a bug in the use of Update Channels when connected online Fixed a bug on GPS time displayed below the plots when doing a zoom and when using a Framelib version that has not the leap seconds of the data read Added an item Unzoom ALL Z can be convenient for camera images Increased size of legends in the plots VIRGO Date April 29 2009 2 5 2 6 Page 6 Bug fixes and new functionalities between v9r12p2 and
37. ld like to get frames from a shared memory 8 where a Siesta program is writing frames Choose Connect to Shm in the Input Menu Provide the name VIRGO Date April 29 2009 Page 35 of the shared memory writer and click on OK Then the Data and Plots panel should show the list of available channels Then once you created your plots push the Start button You should normally get frames from the shared memory and view the desired plots at the rythm of the shared memory writer 2 29 5 Read frames from the dataSender Suppose you would like to get frames from a dataSender that reads data from files and provides them through Ethernet Choose Connect to dataSender in the Input Menu Choose a dataSender name and a file to read or a directory to read and click on OK Then the Data and Plots panel should show the list of available channels Then once you created your plots push the Start button You should normally get frames from the dataSender and view the desired plots at the rythm that can sustain the dataSender VIRGO Date April 29 2009 Page 36 3 The Developer s Manual 3 1 Overview and Installation The data Display version described here can be found in the virgoApp Dy directory organized as the following e in src src mysiesta src aform src userfct directories source code and header files e in mgr directory the compilation Makefiles e in doc directory
38. ld of each panel of the data display VIRGO Date April 29 2009 Page 16 Info Line This line at the bottom of the main panel informs you about the last action made or the current status of the data display Data Display vxrypz curr sl pata an Pios te union mumo ouou e 1 ee vr cen orm Login me cal Figure 2 Main panel of the Virgo Data Display 2 20 The options panel Color2D this button allows to select predefined color tables for the 2D and time frequency plots Log Lin X put Log or Linear scale on the X axis of all the plots Log Lin Y put Log or Linear scale on the Y axis of all the plots Zoom all legends Zoom in or out the legends of all the plots Zoom all stat boxes Zoom in or out the statistics boxes of all the plots Zoom all time strings Zoom in or out the time strings under all the plots Zoom all titles Zoom in or out the titles of all the plots Zoom all labels on X Zoom in or out the X axis labels of all the plots Zoom all labels on Y Zoom in or out the Y axis labels of all the plots Auto deselect Plots selected lines in the plots browser are automatically dese lected each time and Edit Plot panel is closed Auto deselect Channels selected lines in the channels browsers are automati cally deselected each time a plot is made no TOC on off button to read frames without the files TOC Table of Contents In this case reading o
39. mpling Freq The new frequency at which you resample the data in order to view at larger scales the time evolution This field contains by default the initial sampling frequency of the channel Time Shift Percentage of the time window used to shift the time plot visualization Number of FFT to average number of spectra you average Visualization is done each time you add a spectrum so you can see the progression of the averaging Refresh Period in number of FFTs the refresh of the plot s display is done every time this number of FFTs has been computed Zoom freq min Minimal frequency just for visualization no cut in frequency is really done Zoom freq max Maximal frequency just for visualization logx on off button to set log scale on horizontal axis logy on off button to set log scale on vertical axis gridx on off button to set grid lines along horizontal axis gridy on off button to set grid lines along vertical axis autoY on off button to set automatically the right vertical edges unitsY on off button to set right units on the vertical axis noDC on off button to set removal of mean value DC component of the signal decay The averaging of FFTs uses a moving average 2Dcohe A bi coherence plots 2D is made instead of the usual coherence plot Default Put the default values for all the fields or on off buttons VIRGO Date April 29 2009 Page 28 OK Acknowledge the changes you made Those chang
40. mputing an average over N sampling Time Shift Percentage of the time window used to shift the time plot visualization ymin Minimal value of the time plot on vertical axis ymax Maximal value of the time plot on vertical axis Filter Band fmin fmax Min and max frequency of the pass band filter applied on the data before time plot visualization VIRGO Date April 29 2009 Page 24 logx on off button to set log scale on horizontal axis logy on off button to set log scale on vertical axis gridx on off button to set grid lines along horizontal axis gridy on off button to set grid lines along vertical axis autoY on off button to have an automatic set of ymin and ymax while plotting the data unitsY on off button to set right units on the vertical axis noDC on off button to set removal of mean value DC component of the signal Default Put the default values for all the fields and buttons OK Acknowledge the changes you made Those changes will affect all the plots of the same type if you used Edit Clone instead of Edit Cancel Cancel all the changes you made Small circles near each input field If such buttons are selected they indicate that EditClone should apply to those fields even if they have not been changed 2 25 2 Edit panel of FFT plot Name the name of the plot By default it is derived from the channels name Do not put any blank in the plot name this is not managed by Siesta cards
41. n the Edit button of the plots browser is pushed It opens the plot panel Once you changed the plot s parameters you push the button Ok and the function DyEd itPlotCallBack is called In this editing process the following functions have been called DyEditPlot DyPlotToPanel DyRaisePanel DyEditPlotCallBack DyPanel ToPlot DyUpdatePlotBrowser DyClosePanel e DyUpdatePlotBrowser called each time you add or delete a plot in the list e DyPlotToPanel called each time you edit a plot It puts values from the Plot structure to the edition panel e DyPanelToPlot called each time you have edited a plot It puts values back from the edition panel to the Plot structure e DyPutDefaultInPlot called each time you create a new plot by pushing button 1D 2D TIME in the Data and Plots panel e UFrIFileCmIni UFrIFileCmSim These are modified copies of the functions used in siesta to get frames from the network Some added lines allow to interact with the data Display event loop Are also available UFrIFileOnlineSim to read VIRGO Date April 29 2009 Page 39 frames online and UFrIFileDdIni UUFrIFileDdSim to get frames from the Data Distribution server e DyGetConfigfile called when you push the button Load Config of the Config File panel This function calls DyGetConfig e DyGetConfig This function reads a car file using the functions DyGetClocks FromConfig DyGetFilesFromConfig a
42. nd DyGetPlotFromConfig When you give to DyGetConfig a Siesta cards file it only look at the siesta cards beginning with keywords UJMasterClocks UFrIFile UFrIFileOnline UFrIFileCm UFrIFileDd or UFrUnpack cards Moreover after a UFrUnpack card there must be always a card beginning with UHplot1D UHPlot2D UHplotTime UHplotF FT UHpTfct or UH sound e DySetVar This function is called by the DySetPlot function or each time you select a channel in the Data and Plots panel It takes the channel name and type adc or sms data used when a plot is created e DyRaz It is called by the Clear buttons of some browsers and by the buttons Cleaning and Reset All of the main panel Depending on the argument passed it resets the input files list arg 1 the plots arg 2 that means plots list clocks list except the frame clock and all the Plot structure variables the list of data to dump arg 3 the dumped data panel arg 4 the PAW graphical windows only arg 5 or all the previously cited items plus the frame clock arg 0 3 5 Example of data display working steps In the function main fl_do_loop is called within an infinite loop This means that Xforms is indefinitely waiting for an X event any change in the currently displayed panels Once you got a configuration file read via the DyGetConfig function or once you got a frames source whose first frame is read by DyReadFirstFrame and once you set and edited yo
43. ning message e Input To choose the dataDisplay s source of data under frame format This is the first action to do e Configurations To save or load a configuration file This configuration is for now a car file siesta e Data and Plots Once a first frame has been read from the source you selected the adc data or slow monitoring data it contains are shown in the Data and Plots panel Then you can dump or plot those adc or sms channels e Dump To see the current dump of the data you selected e Output Provides access to the Output panel where can be set the options when writing on disk the frames read e Cleaning Remove the graphical windows from the screen VIRGO Date April 29 2009 Page 15 e Reset All Reset all and put the data display in a just started state Except the list of plots in the mainbrowser panel e start Run Frame To set run and frame numbers of the first frame to read e start GPS time duration To set the GPS time of the first frame to read If used then Start Run Frame are put to 1 and 0 and are not used Duration is the number of seconds of data over which you want the display to run once you have pushed the button Start Negative value means infinite e start UTC date same as start GPS time but in explicit UTC date format You can modify this field instead of start GPS time and the start GPS time field will be updated automatically
44. o Data amp Plots Figure 3 The Data and Plots panel of the Virgo Data Display e FFTTIME A time frequency plot for each selected channel is created e TR FCT A transfer function plot between var2 and varl is created e TRFCTTIME A time transfer function plot between var2 and varl is created e COHE A coherence plot between var2 and varl is created e COHETIME A time coherence plot between var2 and varl is created e 1D A distribution plot of each selected channel is created e 1DTIME A time 1D plot of each selected channel is created e 2D A 2d plot is created showing var2 y axis versus varl x axis e RAW A plot is created showing raw values of a 1D or 2D data vector e RAWTIME A plot is created showing versus time raw values of a 1D data vector for instance a spectrum e AUDIO Selected channel can be hear over a given duration after button Stop has been pressed e DUMP Put the selected channels in the list of data channels to dump while reading frames Selecting one channel and pushing one of these buttons creates a plot or audio or dump with default parameters that you can change using the Edit button of the plots browser Selecting several channels of SMS data ADOC or Processed Data VIRGO Date April 29 2009 Page 22 browsers and pushing one of those buttons creates as many plots or audio or dump as there are channels selected If you push 2D
45. on the plot Possibility to rescale a signal in a plot around its Y mean value Possibility to superpose the differential on the plot Possibility to superpose the integral summed from the end of the plot Possibility to superpose the integral summed from the start the plot Possibility to redo operations on signals without starting dataDisplay always from the same directory Macros containing the operations on the signals are kept by default in virgoData DyAlgo Possibility to superpose plots even for signals of different sampling frequencies Possibility to do plots with signals that have sampling frequencies not submultiple of the fastest signal Possibility to change the order of the plots using the and buttons close to the plots browser Possibility to visualize a 1D time plot showing the evolution in time of the 1D distribution of a signal Possibility to superpose the rms curve integration of the spectrum starting at the Nyquist frequency over the spectrum plot rms is not in units sqrt Hz 2 17 Bug fixes and new functionalities from v9r04 Update of channels list button Update Channels according to the GPS start value Explicit use of ffl frame files list files to access huge amount of data Possibility to visualize the raw values of a data vector FrVect of 1 or 2 dimensions This allows to visualize Cameras images or to plot spectra data versus frequency that could be present in a FrProcData structu
46. plot are aligned on those of the plots of same type already present in the browser e Possibility to do Edit Clone without changing parameters of a plot just clicking on the round button next to parameter s field e Possibility to visualize bits of the signal shown on a TIME plot button Bits in the TIME plot edit panel e Possibility to use Pause and Continue buttons when reading data from dataSender e Added TRECTTIME and COHETIME plots that are time frequency plots showing evolution in time of the transfert function only the module and of the coherence function e Added UnZoomX to solve the problem of superposed plot not fully displayed after a zoom unzoom e Possibility to use ZoomAllXAsLast ZoomAllYAsLast UnZoomAllX or UnZoomA ITY also with 2 dim plots VIRGO Date April 29 2009 Page 11 Waiting for an automatic tool I have added a Update Time Freq item in the Zooms menu that updates any frequency axis according to the last zoom made on a time frequency plot When using GetRefPlots the 2D plots are superimposed with their correspond ing reference plots and any other 2 dim plot is replaced by the difference with its reference plot When using GetRefPlots the 1D and 2D plots limits are updated automatically UnZoomY does not take into account anymore the zeros at the end of TIME plot not completely filled When channels is absent or corrupted green or red verti
47. put menu DyMakeSiestaFile called when you save a configuration or most commonly by the DyStart function that is called when you push the button Start Using the structure Plot the data source and the clocks list DyMakeSiestaFile builds the configuration file Siesta cards file dd car that will be used when you push the Start button It calls successively DyMakeClockString DyMakeFileString and DyMakePlotString DySiestaLike called by DyStart just after the call to DyMakeSiestaFile It does the same job as the central part of Siesta siesta c but includes some modification to allow interaction between the siesta loop and the Xforms events loop e DyInteractionSim this function is called by DySiestaLike each time a new frame is read In addition it updates the current run and frame numbers displayed in the main panel It gives the possibility to the user to interact with the GUI while frames are read for instance to use the Stop or Pause buttons DyStart called when the Start button of the main panel is pushed It calls the functions DyMakeSiestaFile and DyStestaLike DySetPlot called each time you push a button like 1D 2D TIME of the Data and Plots panel It looks at the channels you selected and for each of them add a plot in the plots list DyUpdatePlotBrowser and sets its default parameters DyPutDefaultInPlot DyEditPlot It does the same kind of job but this function is called whe
48. re of a frame Possibility to plot spectra in 1 Hz units instead of 1 sqrt Hz VIRGO Date April 29 2009 Page 14 2 18 New functionalities from v9r00 e Possibility to do operations on signals before doing plots for instance you will be able to do a plot on the variable Pr_B1_ACq Pr_B1_ACp sin Pr_B5_DC blue button USERFCT above the proc data browser and button USER FONCTIONS of the mainpanel e Possibility to propagate zoom on X or Y axis on all the plots e Possibility to superpose several signals on the same plot buttons SAME and UN SAME near the plots browser e Possibility to exchange the two variables in a plot 2D a plot TrFct transfert func tion plot or Cohe coherence function plot button EXCHANGE near the plots browser e Possibility to visualize also Sim data in addition to Adc Proc and Sms data e Possibility to update the list of channels with respect to the GPS start time button UPDATE CHANNELS under the simdata browser e A predefined list of servers to connect to when using dataDisplay online button PREDEFINED near the Cm servers browser e Date indicated in the mainpanel under the start GPS time is now in UTC and is updated directly when you change the start GPS time 2 19 The main panel The main panel fig 1 is made of the following buttons and fields e Help A short help to start using the data display e QUIT Quit data display if you answer Yes to the war
49. small input box under the browser allows you a fast search of a name in the browser A delete button allows to delete new channels produced with the User Fct button VIRGO Date April 29 2009 Page 20 e Simulated Data the list of frame s sim channels This is were you can find any simulated data You can select one or several of them and push a plot button TIME 1D FFT It will create a plot for each channel selected To deselect a channel click on it To deselect all the channels use the button deselect all A small input box under the browser allows you a fast search of a name in the browser e Update Channels Changing the start date in the mainpanel and clicking on this button will update the channels lists according to the start date e filter If you write Em BD 01 in this field and press Return then the first items of the corresponding browser will be Em_ACBDCE01 Em_ACBDMCOI Em_SEBDNEOI If you write then all the channels will be presented in alphabetic order e search If you write Em WE in this field the channel s name Em_ACBDWEO1 will be found e USER FCT This button provides a menu The item Operation String of this menu allows the user to define its own operation on the signals and to create new proc signals that can be used to do plots The other items are predefined functions that apply on the adc sim or proc signals previously selected e TRIGGER
50. ta to plot the data to select the data to be viewed to edit plots and superpose them It uses a simple Graphical User Interface Xforms GUI and the graphical capabilities of a standard tool used at CERN ROOT e Xforms 2 is a light and quite easy GUI a free software with many useful GUI objects and a convivial GUI designer e The graphical tools of ROOT 4 are used to view the plots We have added specific features like multizoom start GPS time superposition of reference plots or export of the plots data in ASCII files Figure 1 shows an example of the plots made by the dataDisplay dataDisplay v9r11pl started by verkindt on Apr 21 2007 07 45 00 UTC sac Pr_B1_ACp__ TIME Pr_B1_ACp_1D Pr_B1_ACp_ FFT Pr_B1_ACp_FFTTIME E F Entries 128 20 oat Mean2 194e 08 Z y 0 02 RMS 7 162e 06 do k o 10 0 027 2 10 0 044 i 10 i i fi 10 Ei ul saul ni ol 1w 41m44 41m46 41m48 0 00002 0 0 00002 1 10 10 10 dp 41m45 41m46 41m47 41 mie 858620518 Mar 22 2007 17 41 44 UTC 858620520 Mar 22 2007 17 41 46 UTC dt 58620522 2591 Mar 22 2007 17 41 48 UTC t 0 8192s nAv 152 858620519 2875 Mar 22 2007 17 41 45 UTC Pr_B1_ACp vs Pr_B5_DC_COHE pers Pe_B1_ACp ever Pr B5 DO TRFCT SaWE_FOxLvdt vs SaWE_FOzLvdt_ 2D Gx_B1_Image_ RAW a 1 10 2 ap Kde pao Ein e 100 ca 0 8 107 O 18 i200 1 o E 2 16 180 ost io 1 10 10 10 10 0 ia is 0
51. ugging messages Use colors Created the functions Dy DebugX XX Added more comments and debug messages in URPlot c Simplified the way of compiling under Cygwin build_cygwin no more needed Improved this documentation Bug fixes and new functionalities between v9r11p4 and v9r11p5 Fixed a bug on the time axis of the FFTTIME plots Fixed a bug on the time axis of the RAWTIME plots Fixed a bug in the search fields of the data and plots mainbrowser panel Added possibility to ask remotely through a Cm command that dataDisplay put current plots into a jpg file Added possibility to request ffl directory to the dataSender VIRGO Date April 29 2009 Page 8 e Removed timeout on the frames reception through Cm e Added possiblity to write on disk the frames received button Output on main panel 2 8 Bug fixes and new functionalities between v9r11p1 and v9r11p4 e Put all options like skipFrame noTOC Color2D etc into a specific panel accessible through the Options button of the mainpanel Added possibility to save plots in ps or jpg format Added possibility to run the dataDisplay in background and produce a jpg file Added possibility to stop a dataDisplay remotely through a Cm command Several bug fixes and improvements that I do not remember 2 9 Bug fixes and new functionalities between v9r10 and v9r11p1 e Fixed bug in the management of last data in the buffer for the TIME plots
52. ur plots DySetPlot and DyEditPlot you can push the Start button DyStart that calls DySiestaLike This action has a first consequence the building of a configuration file dd car This is a Siesta cards file which is then read by the function DyStestaLike Within the DySiestaLike loop a periodic call to the function DyInteractionSim allows interactivity with the user Each time you push the Stop button while DySiestaLike is running a plots file dd hsto is written to disk and the DySiestaLike loop is stopped References 1 Frame format specifications Internal notes LIGO T970130 F E and VIR SPE LAP 5400 102 see also http lapp in2p3 fr virgo FrameL VIRGO Date April 29 2009 Page 40 2 Xforms library open source since 2001 http savannah nongnu org projects xforms and http savannah nongnu org download xforms 3 Siesta see documentation in virgoApp siesta xxx doc 4 Root library for data handling and visualization http root cern ch 5 Frame library Virgo note VIR MAN LAP 5400 108 1997 see also http lapp in2p3 fr virgo FrameL 6 CSet package see documentation in virgoApp CSet xxx doc 7 The Cm library Virgo note VIR MAN LAL 5100 112 1998 8 Frame distribution through shared memory Virgo note VIR MAN LAP 5400 113 2000
53. v9r12p3 Improve messages to the users when data are not available Added a menu for connection to a shared memory Fixed a bug in shared memory reconnection mechanism Added possibility to update channels list when connected online Cm or when connected to a shared memory Securized the code to receive frames online against UFrCurFrameH NULL Added possibility when clicking on plot s line with right mouse button to get FFT of Nth derivative or Nth primitive Bug fixes and new functionalities between v9r11p5 and v9r12 or v9r12p1 or v9r12p2 Reduce size of the mainbrowser panel and reorganize buttons in it Put white color in each pad Added option to put white color also in the full ROOT canvas Ask now for a password when connecting for the first time to a dataSender Fixed a bug in the connection to dataSender Simplified and improved the online Cm connection management Use now the function UHplotSetTime also for the 2D plots Fixed a bug in UHplotSetTime function and transfered this function into DyUtil c Added a function UHplotUpdateEnv in URPlot c Added filter for each channels browser of the mainbrowser panel Typing Sc Gc make the browser show first all the channels whose name contains Sc and finishes with Ge Added possibility of several colors for the Reference Plots Choice of color can be done with a number next to file name Added possibility to superpose reference plots while running see persistent r
54. w functionalities between v9r09 and v9r09pl 10 2 13 Bug fixes and new functionalities from v9r09 11 2 14 Bug fixes and new functionalities from v9r08 2 20 12 2 15 Bug fixes and new functionalities from v9r06 12 2 16 Bug fixes and new functionalities from v9r05 2 204 13 2 17 Bug fixes and new functionalities from v9r04 13 2 18 New functionalities from v9r00 4 ok Ye BE ee EE eae Ys 14 2 19 The main panel 643 cu degno strie ato ot ae ee A ee eg 14 220 THe Options ae li ur Lt os aso de n feb Sods He fo ed GA eee di 16 DSL Thedeb g panel croce a oo at Pe eas ae Pes nso Gh es GR Ge a ok a ee es 17 2 22 Input Men s conei a a a a r a Goh orata Pea Boe es 18 2 23 Configurations Menu aoaaa dee e ee eae ee aS ES ES 19 224 DataaAnd Plots a l art dead toda hig te de SG ey SE Be ee 19 2 24 1 The data browsers and buttons 19 2 24 2 The plots browsers and buttons 20 2 25 The editing plot panels ossi natale OE Se eee 23 2 25 1 Edit panel of TIME plot aoaaa a 23 VIRGO Date April 29 2009 2 26 2 27 2 28 2 29 The 3 1 3 2 3 3 3 4 3 5 Page 2 2 25 2 Edit pamelor PIN plot 3 howe els ae lai 24 2 25 3 Edit panel of FFTTIME plot n ho drill E Sek Oe 25 2 25 4 Edit panel of TRECT or COHE plot lt i ius ee de p ee 2 2 25 5 Edit panel of TRFCTTIME or COHETIME plot 28 2 25 0 Edit pane lot L

Download Pdf Manuals

image

Related Search

Related Contents

Veritas 2 User manual 2013.indd  Bedienungs- anleitung  FMC-50 取扱説明書  Series 200 Vacuum Degasser  クリーン F シューズカバー  Instruction Manual - Albatros Golf Solutions  Teufel MediaStation 6 WLAN  liste SUP - Le Grand Chalon  972B DualMag - MKS Instruments, Inc.  

Copyright © All rights reserved.
Failed to retrieve file