Home
GV-AS Controller Quick Start Guide
Contents
1. GeoUision The Vision of Security Quick Start Guide GV AS EV Controller Thank you for purchasing GV AS EV Controller This guide is designed to assist the new user in getting immediate results from the controllers For advanced information on how to use the GV AS100 1010 110 1110 120 210 2110 410 4110 810 8110 and GV EV48 please refer to GV AS EV Controller User s Manual on Software CD C I o ASEV QG D GeoVision 2015 GeoVision Inc All rights reserved Under the copyright laws this manual may not be copied in whole or in part without the written consent of GeoVision Every effort has been made to ensure that the information in this manual is accurate GeoVision Inc makes no expressed or implied warranty of any kind and assumes no responsibility for errors or omissions No liability is assumed for incidental or consequential damages arising from the use of the information or products contained herein Features and specifications are subject to change without notice Note No memory card slot or local storage function for Argentina GeoVision Inc 9F No 246 Sec 1 Neihu Rd Neihu District Taipei Taiwan Tel 886 2 8797 8377 Fax 886 2 8797 8335 http www geovision com tw Trademarks used in this manual GeoVision the GeoVision logo and GV series products are trademarks of GeoVision Inc Windows and Windows XP are registered trademarks of Microsoft Corporatio
2. 1110 120 This section covers the basic settings required to start running GV AS100 1010 110 1110 120 For more settings on GV AS100 110 120 refer to 5 Optional Devices for GV AS100 110 120 The section numbers listed here refers to the GV AS Controller User Manual April 20 2015 1 C GeoUision 1 1 GV AS100 1010 Connect card readers Optional Connect AS100 1010 to a reader 1 2 1 Connecting Card Readers 4 Connect input devices Connect AS100 1010 to input devices Ex a push button to exit 0_ 5 C GeoVision 1 2 2 Connecting Input Devices SUL atk EAA Connect output devices m Connect AS100 1010 to output devices Ex a door lock GV AS100 1 2 3 Connecting Output Devices 4 C Geovision Connect to PC Connect the controller to a computer through RS485 connection AS100 or network connection AS100 amp AS1010 1 2 4 Connecting the PC Connect to Power Connect AS100 1010 to power using the supplied adaptor 1 2 5 Connecting the Power 4 GV AS1010 Programming the GV AS100 1010 Create a Master Card AS100 or Enroll Delete Card AS1010 to add and delete cards For other settings use the built in keypad to type the commands 1 3 Programming Mode 2 April 20 2015 C GeoVision 1 2 GV AS110 1110 Connect card readers Optional Connect AS110 1110 to a reader
3. 4110 810 8110 to readers through Wiegand or RS 485 interface Connect input devices Connect AS410 4110 810 8110 to input devices Ex a push button to exit 5 2 2 Connecting Input Devices Connect output devices Connect AS410 4110 810 8110 to output devices Ex a door lock 5 2 3 Connecting Output Devices Connect Backup Battery Optional Connect AS410 4110 810 8110 to backup battery in case the main power supply fails 5 2 4 Connecting Backup Battery Connect to Power Connect AS410 4110 810 8110 to power using the supplied 12V DC adaptor 5 2 5 Connecting the Power Connect to PC Connect AS410 4110 810 8110 toa computer to access its Web interface and connect with GV ASManager 9 2 6 Connecting the PC GV AS410 4110 810 8110 6 April 20 2015 C GeoVision 2 3 GV EV48 Connect card readers Connect EV48 to readers through RS 485 interface 6 2 1 Connecting RS 485 Card Readers C GeoVision GV EV48 C GeoVision GV EV48 Connect output relay Connect EV48 output relays to the corresponding floor on the elevator control panel b Reset 6 2 2 Connecting Output Relay GV EV48 Connect Backup Battery Optional Connect EV48 to backup battery in case the main power supply fails 6 2 3 Connecting Backup Battery Connect to Power Connect EV48 to power using the supplied 12V DC adaptor 6 2 4 Connecting the Power Connect to PC
4. 2 2 1 Connecting Card Readers 4 Connect input devices Connect AS110 1110 to input devices Ex a push button to exit 2 2 2 Connecting Input Devices Y Connect output devices Connect AS110 1110 to output devices Ex a door lock 2 2 3 Connecting Output Devices y Connect to PC Connect the controller to a computer through RS485 connection AS110 or network connection AS110 amp AS1110 2 2 4 Connecting the PC GV AS110 1110 Connect to Power Connect AS110 1110 to power using the supplied adaptor 2 2 5 Connecting the Power 4 Programming the GV AS110 1110 Create an Enroll Card and a Delete Card to add and delete cards For other settings use the built in keypad to type the commands 2 3 Programming Mode April 20 2015 3 C GeoVision 1 3 GV AS120 Connect card readers Optional Connect AS120 to a reader through Wiegand interface 3 2 1 Connecting a Wiegand Reader Connect input devices Connect AS120 to input devices Ex a push button to exit 3 2 2 Connecting Input Devices Connect output devices Connect AS120 to output devices Ex a door GV AS120 lock 3 2 3 Connecting Output Devices RS485 Connection Connect to PC 3 2 4 A RS 485 Connection Connect AS120 to a computer through RS485 connection or network connection Network Connection 3 2 4 B Network Connection Connect to Power Connect AS12
5. Connect EV48 to a computer to access its Web interface and connect with GV ASManager 6 2 5 Connecting the PC April 20 2015 T eo GeoUision 3 Accessing the Web Interface of the GV AS Controllers After connecting the required wires and cables for the following GV AS Controllers access the Web interface of the GV AS Controller to define the devices connected GV AS1010 1110 210 2110 410 4110 810 8110 and GV EV48 The section numbers listed here refers to the GV AS Controller User Manual Set network configurations Assign a static IP address or set up DDNS to map a dynamic IP address to a static domain name Chapter 7 Installing on a Network Set card readers Define the connected readers by selecting the corresponding doors gates Set Function Configuration Specify the function and the authentication mode for each door gate 8 2 1 Function Configuration Set Parameter Configuration Set the door operation for different situations and enable alarms for each door gate 8 2 2 Parameter Configuration Set Input Configuration Name the input devices connected and set the input type and input function 8 2 6 Input Configuration Set Output Configuration Name the output devices connected and set the output type function and conditions 8 2 7 Output Configuration Static IP address 7 1 Fixed IP connection Dynamic IP address 7 2 DHCP Connection Set Wiegand readers 8 2 8 Wiegand Function Se
6. 0 to power using the supplied 12V DC adaptor 3 2 5 Connecting the Power Add and delete cards Create an Enroll Card and a Delete Card to add and delete cards 3 3 Programming Mode 4 April 20 2015 C GeoVision 2 Physical Wiring for GV AS210 2110 410 4110 810 8110 and GV EV48 2 1 GV AS210 2110 Wiegand Connect card readers 4 2 1 A Wiegand Readers Connect AS210 2110 to readers through Wiegand or RS 485 interface RS485 4 4 2 1 B RS 485 Readers Connect input devices Connect AS210 2110 to input devices Ex a push button to exit 4 2 2 Connecting Input Devices v Connect output devices Connect AS210 2110 to output devices Ex a door lock 4 2 3 Connecting Output Devices 4 Connect Backup Battery Optional Connect AS210 2110 to backup battery in case the main power supply fails 4 2 4 Connecting Backup Battery Connect to Power Connect AS210 2110 to power using the supplied 12V DC adaptor 4 2 5 Connecting the Power 4 15 Gi ASS 10 isk qa Connect to PC Connect AS210 2110 to a computer to access as aia T its Web interface and connect with GV ASManager GV AS210 2110 4 2 6 Connecting the PC April 20 2015 5 C GeoVision Wiegand 5 2 1 A Wiegand Readers RS485 5 2 1 B RS 485 Readers 2 2 GV AS410 4110 810 8110 Connect card readers Connect AS410
7. 20 9 2 4 A Connecting GV AS100 110 120 Connect readers through RS 485 Connect GV ASNet with readers through RS 485 interface 9 2 4 B Connecting GV Readers and GV GF Fingerprint Readers Connect Backup Battery Optional Connect GV ASNet to backup battery in case the main power supply fails 9 2 4 C Connecting Backup Battery Connect to Power Connect GV ASNet to power using the supplied 12V DC adaptor Connect to PC Connect GV ASNet to a computer to access its Web interface and connect with GV ASManager eo GeoUision 5 2 Accessing the Web Interface of GV AS100 110 120 The section numbers listed here refers to the GV AS Controller User Manual Set network configurations Assign a static IP address or set up DDNS to map a dynamic IP address to a static domain name Chapter 7 Installing on a Network Set Wiegand readers ASBox only Set card readers 9 3 2 A Function Setting Define the connected readers by selecting the corresponding doors gates Set RS485 or TCP IP readers 9 3 2 G Extended Reader Set Function Settings Specify the function and the authentication mode for each door gate 9 3 2 A Function Setting Set Parameter Settings Set the door operation for different situations and enable alarms for each door gate 9 3 2 B Parameter Settings Set Input Output Settings ASBox only Name the input output devices connected and define the input output sensors 9 3 2 F In Ou
8. fter the controller is installed on a network GV AS100 110 120 can also connect with GV ASManager for advanced settings Refer to 4 Setting GV AS Controller on GV ASManager for details 10 April 20 2015 C GeoVision 5 1 Physical Wiring of GV ASBox and GV ASNet The section numbers listed here refers to the GV AS Controller User Manual Physical Wiring of GV ASBox Physical Wiring of GV ASNet Connect GV AS100 110 120 Connect GV ASBox with GV AS100 110 120 9 1 4 A Connecting GV AS100 110 120 Connect a Wiegand reader GV ASBox supports connection with one Wiegand reader 9 1 4 B Connecting a Wiegand Reader Connect readers through RS 485 Connect GV ASBox with readers through RS 485 interface 9 1 4 C Connecting GV Readers and GV GF Fingerprint Readers Connect input devices Connect GV ASBox to input devices Ex a push button to exit 9 1 4 D Connecting Input Devices Connect output devices Connect GV ASBox to output devices Ex a door lock 9 1 4 E Connecting Output Devices Connect Backup Battery Optional Connect GV ASBox to backup battery in case the main power supply fails 9 1 4 F Connecting Backup Battery Connect to Power Connect GV ASBox to power using the supplied 12V DC adaptor Connect to PC Connect GV ASBox to a computer to access its Web interface and connect with GV ASManager April 20 2015 11 Connect GV AS100 110 120 Connect GV ASNet with GV AS100 110 1
9. i April 20 2015 eo GeoUision Built in Battery GV AS1010 110 1110 120 210 410 810 amp GV EV48 When the controller runs out of battery the local time on the controller will be reverted back to 1999 12 31 The controller time can be found on the Web interface of the controller on the Time Setting page and in the Access Monitor Alarm Monitor Event Monitor of GV ASManager Time Configuration D n C GeoVision System Local Time Basic Setting Local Time 2014 04 25 13 42 11 Network Setting Time Zone 8 00 Other Setting Firmware Update Local Time Account Setting Advanced Setting Disable Function Setting Setup Parameter Farti Hour Min Timez Parameter Part dis Sas Year Month Date Input Setting When you see the controller year shown as 1999 or 2000 disconnect the controller from power and reconnect it to power If the year is still shown as 1999 or 2000 the controller battery needs to be replaced When this occurs connect the controller to a backup battery and maintain connection with GV ASManager at all times When connected to GV ASManager the controller s time will be synchronized with GV ASManager s time April 20 2015 lil C GeoUision GV AS Controller Quick Start Guide This guide lists the basic steps required to set up a GV AS Controller For detailed instructions refer to the section number listed below each step 1 Basic Setup for GV AS100 1010 110
10. n April 2015 C GeoUision Contents OTE ES castes vtre eis ene EE E easel EE auatenaniwad do natn EE EOE EEE E S i Important Note for Maintaining Power Supply ccceccecceeceeceeeeeeeeseeceeceeeeeeesseeseeees ii GV AS Controller Quick Start GUIdC 0 ccc eee ccc ecceeeeeeeeteeeeeeeeeeeeeeeseeseeeeeeseneeseeeaeenes 1 1 Basic Setup for GV AS100 1010 110 1110 120 0 cece eccseeeeeeaeeeeeeneeees 1 Me CO OF VO VG reece T 2 tA NP 1 TITIO aac tet eta ates sented wipers were totnnnntlapimannateedinvatenduceeweeier 3 Bo NFO arse seers te cacti E A E EEE E 4 2 Physical Wiring for GV AS210 2110 410 4110 810 8110 and GV EV48 5 ET GYA ZTO e TU Ree ne ce A ES 5 2 2 GV AS410 4110 810 911 Oeaicenccccicestiontavtnvaneantdtactnnecieacestieantorstastnmpicaeeennes 6 P ON EVI o e E ee 7 3 Accessing the Web Interface of the GV AS Controllers ccccccecceeceeeeeseeeeeeeeeees 8 4 Setting GV AS Controller on GV ASManager ccccccecceecseeceeeceeeeeseeeeeeeeeeeaeeeeeees 9 5 Optional Devices for GV AS100 110 120 0 cece eec eee eeceeeseeeeeeeeeeeeeeeeeaeeneees 10 5 1 Physical Wiring of GV ASBox and GV ASNEt cccccccecceeeceeeeeeceeeeeeeeeeaeeees 11 5 2 Accessing the Web Interface of GV AS100 110 120 nnnnannnnnnennnnnnennnnnnnn 12 April 20 2015 C GeoUision Important Note for Maintaining Power Supply To make sure GV AS EV Controllers can function pro
11. perly during a power outage be sure to replace the internal battery on the controllers when needed It is also recommended to install a backup battery for compatible GV AS Controllers Refer to the following sections in GV AS Controller User Manual for instructions on how to install a backup battery GV AS100 110 120 through GV ASBox See 9 7 4 F Connecting Backup Battery GV AS100 110 120 through GV ASNet See 9 2 4 F Connecting Backup Battery GV AS210 2110 See 4 2 4 Connecting Backup Battery GV AS410 4110 810 8110 See 5 2 4 Connecting Backup Battery GV EV48 See 6 2 3 Connecting Backup Battery Replaceable Button Cell GV AS100 2110 4110 8110 For GV AS100 2110 4110 8110 you can replace the battery on your own when you see low battery messages and icons in GV ASManager fy File Monitoring View Setup Personnel Language Tools Window Help Aa 2 SGG USSRQ S 2228 0 Controllers 16x16 Status ar en Duress Tamper Fire Alarm Held Open Tailgating Urgent Code Card Mode Card Mode Card Mode Card Mode Card Mode Card Mode Access Monitor Event Monitor 4 b x Info Low Battery Door AS400 Local Time 3 18 2014 4 38 56 PM i GO amp 3 18 2014 4 42 39 PM Note Make sure the plastic insulation film under the battery is removed when using GV AS100 2110 4110 8110 for the first time The low battery messages and icons will appear if the plastic film is not removed i
12. t Function 12 April 20 2015
13. t RS485 or TCP IP readers 8 3 1 Extended Reader Note The Wiegand Function and Output Settings pages are not available for GV AS1010 1110 and GV EV48 For GV EV48 the Input Setting page is also not available April 20 2015 C GeoUision 4 Setting GV AS Controller on GV ASManager After setting up the Web interface connect the GV AS Controller to a GV ASManager Through GV ASManager you can set up the doors and enroll cards The section numbers listed here refers to the GV ASManager User Manual Install GV ASManager Install GV ASManager from the supplied software DVD Chapter 2 Installation Set GV AS Controllers Establish connection between the controllers and GV ASManager 4 2 1 Configuring a Controller Set doors gates Enable the doors on the controllers and configure settings as needed 4 2 2 Configuring a Door Add cards to GV ASManager Enroll cards into GV ASManager and define the card types 4 3 Adding Cards April 20 2015 9 C GeoUision 5 Optional Devices for GV AS100 110 120 To access GV AS100 110 120 on a network an optional device GV ASBox or GV ASNet is required GV ASBox also supports connection with additional input devices output devices and readers through Wiegand interface and RS 485 interface GV ASNet supports additional readers through RS 485 connection You will need to first complete the physical wiring of GV ASBox or GV ASNet before accessing the Web interface A
Download Pdf Manuals
Related Search
Related Contents
Imperial 2207001TNO16 Installation Guide Tripp Lite Standard Computer Power Extension Cord, 10A, 18AWG (IEC-320-C14 to IEC-320-C13), 6-ft. Dezembro/ Janeiro 2011 Instructions / Assembly Stage Eindwerk - DSpace at Howest VIZIO XVT3D424SV LCD TV Action Instruments 2014, mode d`emploi Copyright © All rights reserved.
Failed to retrieve file