AN 025 Getting Started with the KXTI9

image

Contents

1. d AN 025 Tonix i ith the KXTI Kionix Getting Started with the 9 Introduction This application note will help developers quickly implement proof of concept designs using the KXTI9 tri axis accelerometer Please refer to the KXTI9 data sheet for additional implementation guidelines While Kionix strives to ensure that our accelerometers will meet design expectations by default it is not possible to provide default settings to work in every environment Depending on the intended application it is very likely that some customization will be required in order to optimize performance We hope the information provided here will help the developer get the most out of the KXTI9 Circuit Schematic This section shows recommended wiring for the KXTI9 based on proven operation of the part Specific applications may require modifications from these recommendations Please refer to the KXTI9 Data Sheet for all pin descriptions 1 0 Vdd 10 Vdd SCL NC 2 8 NC NC 3 7 INT 4 6 NC 5 1 0UF t Vdd x Figure 1 Application Schematic 36 Thornwood Drive Ithaca NY 14850 USA Kionix 2011 All Rights Reserved Tel 607 257 1080 Fax 607 257 1146 June 22 2011 www kionix com info kionix com Page 1 of 10 AN 025 Quick Start Implementation Here we present four basic ways to initialize the KXTI9 These can vary based on desired operation but generally the initial con
2. 0x10 0 Active Low The interrupt pin will normally be HIGH but will transition to LOW when an interrupt is triggered 1 Active High The interrupt pin will normally be LOW but will transition to HIGH when an interrupt is triggered Enable Disable IEN bit 5 0x20 0 Disabled Interrupt conditions will not be reflected on the physical interrupt pin 1 Enabled Interrupt conditions will be reflected on the physical interrupt pin A Few Interrupt Tips Read the Interrupt Release Register to Clear In latched mode the INT_REL register must be read in order to clear the physical interrupt pin This will also clear the Interrupt Source Registers 1 and 2 and the INT bit 0x10 in the Status Register Microcontroller GPIO Interrupt Handling GPIO configuration is based solely on the connected hardware The KXTI9 can be configured to issue interrupts depending on how the GPIO is programmed to catch them if this is not the case please contact your Kionix Sales Representative Generally when an interrupt is triggered the developer should take the following steps 1 Disable GPIO interrupt 2 Clear GPIO interrupt and generate desired functionality 3 Enable GPIO interrupt These steps should be taken without calling any I2C transactions if done in an interrupt context because the operating system or kernel will not allow busy waiting on an I O operation during an interrupt service routine In
3. onix Page 7 of 10 AN 025 expiration of this timer while reporting of double tap events will occur at the expiration of the second latency timer This timer is defaulted to 0 4 seconds General Tips If the Window Timer is one more than the TDT Timer the engine will only report single tap events This can result in more responsiveness for demanding applications Masking directions that are unused by the application can reduce the occurrence of anomalous tap direction resolutions For more information on the tap double tap engine please see the KXTI9 Product Specification Sample Buffer Function The Sample Buffer Function generates an interrupt when the buffer reaches the sample threshold or becomes full depending on how it has been configured Buffer Resolution In 8 bit mode each 3 axis sample is 3 bytes and the buffer can hold a maximum of 84 samples In 12 bit mode each 3 axis sample is 6 bytes and the buffer can hold a maximum of 41 samples BUF RES bit 6 0x40 0 The buffer will accumulate 8 bit sample data 1 The buffer will accumulate 12 bit sample data Buffer Mode Selection In FIFO Stream and FILO modes the buffer accumulates data until the programmed sample threshold is reached at which point a watermark interrupt WMI is triggered until the buffer sample level is brought below the sample threshold In Trigger mode the buffer will hold the most recent number of samples dictated b
4. the default ODR 50Hz the watermark interrupt will fire every 500ms to indicate that 25 3 axis samples have been collected Buffered data can be read in a block transfer from register 0x7F Timing Requirements There are several timing requirements that developers should keep in mind when working with the KXTI9 12C Clock The 1 C Clock rate can be up to 400Khz Power Up to Communication After the part is powered up it typically takes 10ms before it is ready for lC communication Enable to Valid Outputs In low power 8 bit resolution mode after the part is enabled PC1 bit in Control Register 1 is asserted it takes 50us before the acceleration outputs are valid Software Reset Power On Reset Delay After a Software or Power On Reset the part takes 100ys before it is ready for C communication Accelerometer Placement and Orientation Placement It is important to note that the placement of the accelerometer within the target device can have a significant effect on tap double tap direction resolution If tap detection is desired the part should be placed as far away from the edges of the device housing as possible with the ideal location being at the target device s center of mass Orientation While it is recommended to align the accelerometer s axes with those of the target device it will sometimes be desirable or necessary to alter the part s orientation with respect to the device housing Rotating abo
5. 8 bit or 12 bit output data rate high pass filter settings WUF_THRESH and WUF_TIMER register values or mask any of the axes Rotation This utility allows the user to monitor the orientation of the accelerometer It can be used to determine whether the accelerometer is in the face up face down left right up or down orientations Options are available to change the resolution 8 bit or 12 bit output data rate TILT_TIMER TILT_ANGLE or HYST_SET hysteresis register values or mask any of the axes Tap Detection This utility allows the user to detect tap double tap events and see the axis and direction in which the events occur Options are available to change the resolution 8 bit or 12 bit output data rate TDT Tap Double Tap Timer TDT_H THRESH TDT_L_ THRESH TDT_TAP_TIMER TDT_TOTAL_TIMER TDT_LATENCY TIMER or TDT_WINDOW_TIMER register values or mask any of the axes The Kionix Advantage Kionix technology provides for X Y and Z axis sensing on a single silicon chip One accelerometer can be used to enable a variety of simultaneous features including but not limited to Hard Disk Drive protection Vibration analysis Tilt screen navigation Sports modeling Theft man down accident alarm Image stability screen orientation amp scrolling Computer pointer Navigation mapping Game playing Automatic sleep mode Theory of Operation Kionix MEMS linear tri axis accelerometers function on the principle of differen
6. cing the user and the pin 1 indicator is oriented so that it is in the top left corner the part is in the Y or UP position If the user then turns the part 90 counter clockwise so that pin 1 is in the bottom left corner it will be in the X or RIGHT position Continued rotation of the part counter clockwise results in the Y or DOWN position when pin 1 is in the bottom right corner and X or LEFT when pin 1 is in the top right corner Setting the part on a flat surface with the part number and pin 1 indicator facing the sky results in the Z or FACE UP state Likewise flipping the part over to expose the physical pins to the sky would be the Z or FACE DOWN state an ee a 7 o BE a Sonor Top Up Right Down Left Face up Face down ee a State Masking Each of the 6 possible tilt position states can be masked using Control Register 2 To mask an entire axis both possible states for that axis will have to be masked Note that to mask a state the bit associated with that state needs to be set to 0 Timers and Thresholds Tilt Timer This timer establishes the number of Tilt ODR cycles that a new tilt state must be active before an interrupt is triggered and the position registers are updated The Tilt ODR is dictated by the OTPA and OTPB bits in Control Register 3 q Kionix 2011 All Rights Reserved ET June 22 2011 Kionix Page 5 of 10 AN 025 Tilt Angle The tilt engine uses acc
7. ed and will not generate an interrupt 1 Events in the Z axis are unmasked and will generate an interrupt Timers and Thresholds WUF Wake Up Function Timer This timer establishes the number of ODR cycles that the acceleration on an unmasked axis must be above the WUF threshold before a wake up interrupt is triggered Each count in this register equals one Motion Detection ODR cycle as dictated by the OWUFA and OWUFB bits in Control Register 3 WUF Threshold This threshold determines how much acceleration is required in an unmasked axis in order to trigger a wake up interrupt that causes the part to transition from inactivity to activity Tap Double Tap Function Tap Direction Resolution and Reporting Interrupt Source Register 1 Indicates the direction of a tap or double tap event Register Name Address Value Hex Binary Bit INT_SRC_REG1 0x15 0001 0101 Value 7 6 5 4 3 2 1 0 X X TLE TRI TDO TUP TFD TFU amp K onix Bit Description TLE X Negative X Reported TRI X Positive X Reported TDO Y Negative Y Reported Z TUP Y Positive Y Reported TFD Z Negative Z Reported TFU Z Positive Z Reported Kionix 2011 All Rights Reserved June 22 2011 Page 6 of 10 AN 025 Note that all tap double tap directions are with respect to the accelerometer itself If the accelerometer s orientati
8. eleration due to gravity to determine tilt position state As such it is unable to determine the rotational position of the part when the Z axis is in parallel with the direction of gravitational acceleration This state for the purposes of the Tilt Angle variable is referred to as zero degrees The Z axis must be a certain angle away from the direction of gravity in order for tilt changes to be registered on the X and Y axes The Tilt Angle register is used to tell the engine at what angle it should start looking at X and Y axis acceleration instead of Z Motion Detection The Wake Up Function generates an interrupt when the part transitions from an inactive to an active state as determined by the WUF_TIMER and WUF_THRESH register values If the interrupt is configured in unlatched mode it will be de asserted when the part transitions from an active to an inactive state Axis Masking It is possible to mask all wake up events which occur on a particular axis or axes This is done with the three bits XBW YBW and ZBW in Interrupt Control Register 2 XBW bit 7 0x80 0 Events in the X axis are masked and will not generate an interrupt 1 Events in the X axis are unmasked and will generate an interrupt YBW bit 6 0x40 0 Events in the Y axis are masked and will not generate an interrupt 1 Events in the Y axis are unmasked and will generate an interrupt ZBW bit 5 0x20 0 Events in the Z axis are mask
9. er the capture has finished The status bar is used to notify the user of a capture in progress The application will continue to collect data until the user clicks the Stop button or the resulting capture file has exceeded the file size limits 1Gigabyte We recommend collecting the data for at least 120 seconds Captured data will be saved as a list of comma separated values csv Each entry in the list is comprised of a time followed by the raw count for each axis x y and z respectively Select Save or Save As from the File menu to save the file Open the saved file using Excel Calculate the average of the samples This gives the noise of the accelerometer in raw counts q Kionix 2011 All Rights Reserved ET June 22 2011 Kionix Page 9 of 10 AN 025 SensorCalc This application allows the user to test and calculate the zero g offset and sensitivity parameters of the accelerometer Once the accelerometer is properly placed relative to the Earth s gravity simple mouse clicks initiate a series of test sequences that result in the display of raw count data SensorMap This application allows the user to read and write to specific registers of the accelerometer The registers and their values are all displayed simultaneously on one color coded grid Motion This utility allows the user to test whether the accelerometer has detected motion on any of the axes Options are available to change the resolution
10. figurations that a developer will want to try are 1 read back acceleration data 2 activate the tilt position function 3 activate the tap double tap function and 4 activate the sample buffer function These cursory solutions are provided as a means for configuring the part to a known operational state Note that these conditions just provide a starting point and the values may vary as developers refine their application requirements 1 Read Back Acceleration Data Write 0x80 to Control Register 1 to assert PC1 Power Control bit set the G range to 2g and set the resolution to 8 bits Register Name Addresa l Hex Binary Binary CTRL_REG1 0x1B 0001 1011 0x80 1000 0000 Acceleration data can now be read from the XOUT YOUT and ZOUT registers Value 2 Activate Tilt Position Function Write 0x01 to Tilt Timer Here we assume a 80ms timer will be sufficient this is based on the default Tilt Output Data Rate of 12 5Hz Write 0x81 to Control Register 1 to assert PC1 and TPE Tilt Position Enable bit set the G range to 2g and set the resolution to 8 bits Register Name Address g Hex Binary Hex Binary TILT_TIMER 0x28 0010 1000 0x01 0000 0001 CTRL_REG1 0x1B 0001 1011 0x81 1000 0001 Changes to tilt position state will now be reflected in bit 4 of STATUS_REG INT bit bit 0 of INT_SRC_REG2 TPS bit TILT_POS_CUR and TILT_POS_PRE registers and also on the p
11. hysical interrupt pin if IEN is asserted in INT _CTRL_REG1 3 Activate Tap Double Tap Function Write 0x84 to Control Register 1 to assert PC1 Power Control bit and TDTE Tap Double Tap Enable bit set the G range to 2g and set the resolution to 8 bits R uister Name Address Value g Hex Binary Hex Binary CTRL_REG1 0x1B 0001 1011 0x84 1000 0100 Tap double tap events will now be reflected in bit 4 of STATUS_REG INT bit bits 2 and 3 of INT_SRC_REG2 TDTS1 and TDTSO bits and INT_SRC_REG1 tap direction registers and also on the physical interrupt pin if IEN is asserted in INT_CTRL_REG1 4 Activate Sample Buffer Function Write 0x19 to Buffer Control Register 1 to set the sample threshold to 25 Write 0x80 to Buffer Control Register 2 to enable the buffer in FIFO mode Write 0x80 to Control Register 1 to assert PC1 Power Control bit set the G range to 2g and set the resolution to 8 bits q Kionix 2011 All Rights Reserved June 22 2011 Ktonix Page 2 of 10 AN 025 Recister Name Address Value g Hex Binary Hex Binary BUF_CTRL1 0x32 0011 0010 0x19 0001 1001 BUF_CTRL2 0x33 0011 0011 0x80 1000 0000 CTRL_REG1 0x1B 0001 1011 0x80 1000 0000 Watermark interrupts will now be reflected in bit 4 of STATUS_REG INT bit and bit 5 of INT_SRC_REG2 WMI bit and also on the physical interrupt pin if IEN is asserted in INT_CTRL_REG1 At
12. on does not coincide with that of the project device some conversion must be done to the tap direction output Direction Masking Each of the 6 possible tap double tap directions can be masked using Interrupt Control Register 3 To mask an entire axis both possible directions for that axis will have to be masked Note that to mask a direction the bit associated with that direction needs to be set to 0 Timers and Thresholds Tap ODR The output data rate for the tap double tap engine is variable between 12 5Hz and 1600Hz The Tap ODR is dictated by the OTDTH bit in Control Register 2 and the OTDTA and OTDTB bits in Control Register 3 All tap timers are based on this ODR which defaults to 400Hz Each count in every tap timer represents one cycle of this Tap ODR when using data rates of 400Hz or less Each count represents two ODR cycles when using 800Hz or four ODR cycles when using 1600HZz TDT Tap Double Tap Timer This timer establishes the minimum time separation between the first tap and the second tap in a double tap event This timer defaults to 0 3 seconds IDT H THRESH This is the 9 bit upper jerk threshold for all tap events If the performance index PI of a potential tap event is greater than this threshold the event cannot be classified as a tap event This threshold is defaulted to 7j jerk Performance index is calculated as follows X X current X previous Y Y current Y previous Z Z cur
13. rent Z previous PI X Y Z TDT L THRESH This is the 7 bit lower jerk threshold for all tap events If the performance index of a potential tap event is less than this threshold the event cannot be classified as a tap event This threshold is defaulted to 1j Note that this register also contains bit O of the TDT_H_THRESH in its MSB TDT TAP TIMER This register contains two timers which dictate the minimum and maximum times that a potential tap event must be above the performance index low limit TDT_L_ THRESH and below the performance index high limit TDT_H_THRESH Bits 0 through 2 represent the low limit which defaults to 0 005 seconds while bits 3 through 7 represent the high limit which defaults to 0 05 seconds TDT TOTAL TIMER This register sets the total amount of time that the two taps in a double tap event can be above the performance index threshold TDT_L_THRESH This timer is defaulted to 0 09 seconds TDT LATENCY TIMER This timer is triggered on a tap event and represents the time period that a tap event will only be characterized as a single tap The second tap of a double tap event must occur outside of this timer This timer is defaulted to 0 1 seconds TDT WINDOW_TIMER This timer represents the total time for the entire tap event single or double to occur Reporting of single tap events on the physical interrupt pin will occur at the q Kionix 2011 All Rights Reserved June 22 2011 K
14. terrupt Polling If physical interrupts are not used a polling mechanism can be devised which checks the INT bit in STATUS REG This mechanism should then look at INT SRC _REG2 to determine which engine caused the interrupt and what steps should be taken before clearing the interrupt source information by reading the INT_REL register Digital Engine Operation Tilt Position Function Position Nomenclature and Reporting Tilt Position Current Indicates the current tilt position of the device Defaults to 0x20 left Tilt Position Previous Indicates the previous tilt position of the device Defaults to 0x20 left Kionix 2011 All Rights Reserved June 22 2011 K onix Page 4 of 10 AN 025 Address Value Hex Binary Bit 7 6 5 4 3 2 1 0 TILT_POS_CUR 0x10 0001 0000 Value X X LE RI DO UP FD FU TILT_POS PRE 0x11 00010001 Value X X LE RI DO UP FD FU Register Name Bit Description LE Left State X RI Right State X DO Down State Y UP Up State Y FD Face Down State Z FU Face Up State Z Note that all tilt position states are with respect to the accelerometer itself If the accelerometer s orientation does not coincide with that of the project device some conversion must be done to the tilt position state outputs Orientation If the part is set on its edge with the part number fa
15. this should not be necessary if using the default value for Tilt Angle but it s worth looking into if problems continue q Kionix 2011 All Rights Reserved June 22 2011 Ktonix Page 8 of 10 AN 025 WUF Wake Up Function Interrupt Not Working Make sure that the WUF engine is enabled WUFE bit in Control Register 1 Try altering the threshold requirements to achieve desired operation If the part is waking up too easily try increasing the threshold If the interrupt is not firing at all the threshold may be set too high Try shortening the timer requirements and make sure the acceleration on an unmasked axis is above the threshold until the expiration of the WUF Timer TDT Tap Double Tap Interrupt Not Workin Make sure that the TDT engine is enabled TDTE bit in Control Register 1 Try altering the threshold requirements to achieve desired operation If the part is generating interrupts too often perhaps due to a large noise floor created by excessive environmental vibrations try increasing the performance index low threshold TDT_L_THRESH and or reducing the performance index high threshold TDT_H_THRESH If the interrupt is not firing at all perhaps the low threshold may be set too high or the high threshold may be set too low There are many timers in this engine which have to work together closely so for standard operation if one timer is changed the other timers may need to be changed propor
16. tial capacitance Acceleration causes displacement of a silicon structure resulting in a change in capacitance A signal conditioning CMOS technology ASIC detects and transforms changes in capacitance into an analog output voltage which is proportional to acceleration These outputs can then be sent to a micro controller for integration into various applications For product summaries specifications and schematics please refer to the Kionix MEMS accelerometer product sheets at http www kionix com sensors accelerometer products php q Kionix 2011 All Rights Reserved June 22 2011 Ktonix Page 10 of 10
17. tionally Accelerometer USB Development Kit Kionix offers an Accelerometer USB Development Kit that can be used to quickly begin the development of applications and firmware that incorporate Kionix accelerometers including the KXTI9 The Development Kit provides a common interface to Kionix evaluation boards For additional information regarding the development kit please refer to Kionix Application Firmware Development Kit user s manual Here is a brief description of the applications and utilities supported by the development kit SensorScope This application allows the user to monitor data coming from the attached sensor This data can be saved to a file or viewed in real time With only two verification steps the application will display a series of graphs representing acceleration with respect to time for each axis This data can be used to measure the noise of the accelerometer by using the following steps Place the evaluation board on a flat surface in the desired orientation Tochange the application settings select Settings from the Edit menu On this menu the following settings can be changed Sampling Rate The rate at which the software queries the accelerometer for axis data Realtime Interval The amount of data the software will buffer and display in real time Select the capture button The application will begin to capture data immediately Captured data is written to a file and will not be viewable until aft
18. ut the Z axis at intervals of 90 degrees or about the X or Y axes at intervals of 180 degrees should not impact functionality However it is highly recommended that the device is not rotated 90 or 270 degrees about the X or Y axes Due to the asymmetrical nature of the tilt position function altering the orientation of the Z axis in this manner can cause incorrect screen rotation direction resolution Interrupt Configuration The physical interrupt has 8 possible configurations based on two states for each of the three customizable variables located in Interrupt Control Register 1 Alternate Unlatched Response IEU bit 2 0x04 0 Normal mode Latched or pulse response is dictated by the IEL bit q Kionix 2011 All Rights Reserved June 22 2011 Ktonix Page 3 of 10 AN 025 1 Alternate mode If the motion interrupt feature is enabled response will always be unlatched regardless of the value of the IEL bit This means that when a motion event is detected the interrupt will transition When the motion event has ended the interrupt will return The transition state and return state are determined by the polarity bit IEA Latched Pulsed IEL bit 3 0x08 0 Latched mode When an interrupt is triggered it will remain active on the pin until cleared 1 Pulse mode When an interrupt is triggered it will cause a short 50us pulse on the pin and clear itself Polarity IEA bit 4
19. y the programmed sample threshold until one of the other embedded engines triggers an interrupt At this point the buffer will fill up the rest of the way and if enabled a buffer full interrupt BFI will be triggered For more information on the operation of the sample buffer please see the KXTI9 Product Specification Troubleshooting All Interrupt Issues Make sure the KXTI9 is configured to issue interrupt signals in the way that your GPIO is programmed to handle them An oscilloscope on the physical interrupt pin can be a valuable tool to confirm physical interrupt operation Double check the Tilt Position State Mask bits in Control Register 2 Tilt Position Function the axis mask bits in Interrupt Control Register 2 Wake up Function and or the Tap Double Tap Mask bits in Interrupt Control Register 3 Tap Double Tap Function The Tilt Timer WUF Timer and TDT Timer s are based on their respective Output Data Rates so make sure the correct cycle time is used when calculating the expected timer length please refer to the KXTI9 product specification Tilt Interrupt Not Working Make sure that the Tilt Position engine is enabled TPE bit in Control Register 1 Try shortening the timer requirements and make sure the next state transition does not occur until after the expiration of the Tilt Timer Try increasing the Tilt Angle to ensure that the engine can see the transition between the X and Y axes and the Z axis