1. 0 25 50 75 100 0 25 50 75 100 Percent Load Percent Load 1400 VA 2200 VA Run Time Mins Run Time Mins 0 25 50 75 100 0 25 50 75 100 Percent Load Percent Load 21 AUDIBLE ALARM CONDITIONS CONDITION ALARM Battery mode utility failure One short beep every ten seconds more than two minutes of run time remaining Low battery Two short beeps every five seconds less than two minutes of run time remaining Battery replacement Two second beep every minute UPS output overload One short beep every second UPS fault Continuous tone FUSE REPLACEMENT PROCEDURES FOR 700 VA MODELS Insert flat blade screw AC Inlet driver into slot and pull fuse holder out to remove Fuse Holder CAUTION Before changing the supply fuse turn off the UPS and unplug the input cord from the AC input power supply and from the UPS 1 Remove the fuse holder by inserting a flat blade screwdriver into the slot and pulling out as indicated in the figure above Remove the input fuse Remove the spare fuse from its position by using the screwdriver to push it out Place spare fuse in the input fuse position and replace the fuse holder The fuse holder will lock into position 5 Reconnect the input power lead to the UPS and the input power lead
2. Ensure UPS is off Disconnect all loads and ensure nothing is lodged in output receptacles Ensure loads are not defective or shorted internally Internal fuse is blown indicating internal fault Do not attempt to open or service the UPS Contact your dealer or LTS Utility indicator flashing UPS not plugged in UPS is operating in battery mode make certain UPS is securely plugged into the wall receptacle UPS input protection has opened UPS is operating in battery mode Save data and close applications Replace UPS input fuse or reset input breaker then restart UPS Utility voltage out of UPS input range UPS is operating in battery mode Save data and close applications Ensure utility supply voltage is within acceptable limits for UPS UPS has reduced battery time Batteries not charged Keep UPS plugged in continuously at least 24 hours to recharge batteries UPS is overloaded Check load level display and remove non essential loads Batteries may not be able to hold a full charge due to age Replace batteries Contact your dealer or LTS for replacement battery kit Fault indicator and diagnostic LED A are illuminated UPS fan failure or battery overcharge UPS requires service Contact your dealer or LTS Fault indicator and diagnostic LED B are illuminated UPS failed the battery test Replace batteries Contact your dealer or LTS f
3. A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed before replacing the batteries e Turn off and disconnect the UPS from utility power prior to opening the battery replacement door Remove rings watches and other metal objects Use a Phillips cross head screwdriver with insulated grips Do not lay tools or other metal objects on top of the batteries If the battery replacement kit is damaged in any way or shows signs of leakage contact your dealer immediately e Do not dispose of batteries in a fire the batteries may explode e f you feel unqualified to replace the battery do not open the battery door Call Liebert Technical Support LTS World Wide Technical Support numbers are located at the end of this section 1 Grasp the front bezel near the top and pull forward 2 Rotate the bezel upward and lay it on top of the UPS 3 Loosen the two screws at top of the battery door and remove door by pulling it forward slightly and lifting it off Lay battery door and screws aside for reassembly 4 700 1000 1400 VA models gently pull battery wiring out and disconnect the two wires one red and one black 2200 VA models pull apart connectors A and B 5 Grasp white pull tabs located on sides of the front battery and pull batteries out of the UPS 6 Unpack new batteries taking care not to destroy the packing 7 Slide new batteries into th
4. RFI They minimize any surges or interference present in the utility line and keep the sensitive equipment protected AUTOMATIC VOLTAGE REGULATOR In normal operation the Automatic Voltage Regulator AVR passes utility AC power to the connected load When utility power voltage is outside acceptable limits the AVR activates It raises undervoltage power and lowers overvoltage power This keeps the UPS output voltage within the connected equipment s tolerances and allows wide utility voltage fluctuations without utilizing battery power BI DIRECTIONAL CONVERTER In normal operation the bi directional converter converts utility AC power into regulated DC power to float charge the battery system Upon a utility power failure the bi directional converter receives its required energy from the battery and inverts it into precise regulated sinewave AC power Charging takes place whenever the UPS is plugged into the wall outlet whether it is ON or OFF and utility power is within acceptable limits BATTERY The PowerSure Interactive utilizes valve regulated nonspillable lead acid batteries At typical room temperatures and with the UPS float charging the battery system will last many years For battery run times refer to the Typical Battery Discharge Curves INPUT OUTPUT TVSS Automatic L and Voltage L EMI RFI Filters Regulator Battery Bi Directional Converter MINI TOWER INSTALLATION 1 Unpack the
5. freight collect to User at User s expense Products shipped by User to Liebert which have incurred freight damage due to User s improper packaging of the product will not be covered by this Warranty and any repairs or replacement parts components or products needed will be invoiced in the full current price amount and returned freight collect to User Subject to the limitations specified herein Liebert will repair or replace at its option without charge for Liebert labor or materials subsequent to it s inspection and F O B Liebert s facility the product shipped to Liebert with a Return Authorization number and warranted hereunder which does not conform to this Warranty Replacement products shipped to User prior to User s shipment of the claimed defective product to Liebert under Liebert s unit exchange option program shall be invoiced in the full current price amount should User fail to return the claimed defective product to Liebert within thirty 30 days of receipt of the replacement product Warranty coverage will be extended only after Liebert s inspection discloses the claimed defect and shows no signs of treatment or use which would void the coverage of this Warranty continued on next page 25 LIMITED WARRANTY continued Items Not Covered By Warranty THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY misuse improper application wrong or inadequate electrical current or connection inadequate water or drain servic
6. overload Load Battery 51 to 75 load Level Indicators 26 to 50 load 0 to 25 load Utility High Low uu MEM Alarm silence Test B ED ON ovo LED OFF UTILITY HIGH LOW MODE OPERATION If high or low voltage conditions occur the PowerSure Interactive UPS will automatically correct the utility voltage by either lowering or raising the input voltage condition The UPS will continue to correct these conditions indefinitely without draining battery power The figure below indicates approximately 51 7596 loading while automatically correcting the utility voltage Load Battery Level Indicators Utility High Low Utility Alarm silence Test On Off BATTERY MODE OPERATION Battery mode occurs in event of extreme input conditions or complete utility failure The battery system along with the bi directional converter generates power for the connected load During battery mode an alarm sounds every 10 seconds This will change to 2 beeps every 5 seconds when battery runs low approximately 2 minutes remaining Each load battery level indicator represents a 25 capacity level As capacity decreases fewer indicators remain illuminated Utility LED will flash every second indicating the UPS is operating from battery mode Battery mode supports a full rated load for approximately 5 minutes before it shuts down To increase this time turn off non essential pieces of equipme
7. pull on the white tabs located on both sides of the battery until wiring is exposed Figure 3 Disconnect red wire figure 4 and the black wire figure 5 2200 VA model Pull apart the Battery harness connector Figure 6 amp 7 Remove batteries Unpack new batteries taking care not to destroy the packing 5 Slide new batteries into the cavity noting the white pull tabs are facing outward 6 For 700 1000 1400 VA models Connect the battery wires first black to black then red to red For 2200 VA models Connect the battery harness connector Push batteries back into cavity NOTE There will be a small spark when connecting the Red to Red connectors on 700 1400 VA models and on the 2200 VA model when connecting the battery harness connector This is normal and will not harm you or the UPS 7 Replace the Battery retaining plate by inserting the 4 screws into their associated holes Tighten the 4 screws to secure the battery retaining plate in place 8 Replace the Battery door by inserting the four 4 screws into their associated holes Tighten the four 4 screws to secure the battery door in place 9 Dispose of batteries in accordance with your local laws and regulations 17 Figure 1 Figure 2 Figure 3 Figure 4 Figure 6 TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the PowerSure Interactive UPS develops a problem Use this infor
8. 0F2 or Panasonic LC R127R2CH1 Panasonic LC R0612CH1 Transfer Time 2 6 ms typical Back up Time See Typical Battery Discharge Curves Recharge Time 3 Hours to 95 capacity after full discharge into 100 load ENVIRONMENTAL Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 45 F to 122 F 15 C to 50 C Relative Humidity 0 to 95 non condensing Operating Elevation Up to 10 000 ft 3000 m at 35 C without derating Storage Elevation 50 000 ft 15 000 m maximum Audible Noise lt 45 dBA at 1 meter AGENCY Safet RFI EMI Immunity UL 1778 c UL Listed FCC Part 15 Subpart B Class A IEC 801 2 Level 4 IEC 801 4 Level 4 IEEE 587 Category A 23 RACKMOUNT SPECIFICATIONS Model Number PS2200RM 120 Model Rating VA W 700 450 1000 670 1400 950 2200 1600 ae 5245721 483 x 457 x 133 483 x 457 x 133 483 x 457 x 133 483 x 457 x 178 DOA SERE 699 x 610 x 279 699 x 610 x 279 699 x 610 x 279 699 x 610 x 305 WEIGHT Ibs kg Unit 41 5 18 9 51 29 23 3 57 2 26 0 86 0 39 1 Shipping 50 82 23 1 59 85 27 2 66 1 30 0 95 3 43 3 INPUT AC PARAMETERS Voltage Range Voltage Raise 120 VAC 25 23 Maintains output to 120 VAC 14 when input is 120 VAC 25 Voltage Lower Maintains output to 120 VAC 10 when input is 120 VAC 23 Frequenc 45 55 Hz or 55 65 Hz auto sensing Input Power Cord 6 ft detachable w 6 ft attached w 6 ft attached w 6 ft at
9. E AND EXCLUSIVE REMEDY IS REPAIR OR REPLACEMENT OF THE LIEBERT PRODUCT AS SET FORTH HEREIN IF USER S REMEDY IS DEEMED TO FAIL OF ESSENTAIL PURPOSE BY A COURT OF COMPETENT JURISTICTION LIEBERT S RESPONSIBILITY FOR PROPERTY LOSS OR DAMAGE SHALL NOT EXCEED ONE TIMES THE NET PRODUCT PURCHASE PRICE IN NO EVENT SHALL LIEBERT ASSUMEANY LIABILITY FOR INDIRECT SPECIAL INCIDENTAL EXEPLARY OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER INCLUDING WITHOUT LIMITATION LOST PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA WHETHER ANY CLAIM IS BASED UPON THEORIES OR CONTRACT NEGLIGENCE STRICT LIABILITY TORT OR OTHERWISE Miscellaneous NO SALESPERSON EMPLOYEE OR AGENT OF LIEBERT IS AUTHORIZED TO ADD OR VARY THE TERMS OF THIS WARRANTY Warranty terms may be modified if at all only by a writing signed by a Liebert officer This Warranty is effective as of the date of receipt of full payment and supersedes all previous warranties Liebert reserves the right to supplement or change the terms of this Warranty in any subsequent warranty offering to User or others In the event that any provision of this Warranty should be or becomes invalid and or unenforceable during the warranty period the remaining terms and provisions shall continue in full force and effect This Warranty is given in and intended to be construed under the laws of the State of Ohio This Warranty represents the entire agreement between Liebert and User with respect to the subjec
10. ROTECTION PowerSure Interactive 700 2200 VA 120 V UsER MANUAL English IMPORTANT SAFETY INSTRUCTIONS WARNING Do not attempt to service this product yourself except to replace the battery Opening or removing the cover may expose you to dangerous voltages even when the AC cord is disconnected from the electrical outlet Refer all servicing to qualified service personnel 1 SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS THAT SHOULD BE FOLLOWED DURING INSTALLATION AND MAINTENANCE OF THE UNINTERRUPTIBLE POWER SYSTEM UPS AND BATTERIES CONSERVER CES INSTRUCTIONS CETTE NOTICE CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SECURITE 2 This product is not intended for use with life support and other U S FDA designated critical devices See Limited Warranty 3 CAUTION A BATTERY PRESENTS A RISK OF ELECTRICAL SHOCK OR BURN FROM HIGH SHORT CIRCUIT CURRENT OBSERVE PROPER PRECAUTIONS ATTENTION UNE BATTERIE PRESENT UN RESQUE DE CHOC LECTRIQUE OU DE BRULURE PAR TRANSFERT D NERGIE SUIVRE LES PRECAUTIONS QUI S IMPOSENT 4 WHEN REPLACING THE BATTERIES USE THE SAME NUMBER AND TYPE OF BATTERIES PROPER DISPOSAL OF BATTERIES IS REQUIRED REFER TO YOUR LOCAL CODES FOR DISPOSAL REQUIREMENTS POUR LE REMPLACEMENT UTILISER LE MEME NOMBRE ET TYPE DE BATTERIES L ELIMINATION DES BATTERIES EST REGLE MENTEE CONSULTER LES CODES LOCAUX A CER EFFET 5 Read all safety and operating instruc
11. UPS carefully noting the packing method Retain the box and packing material for possible future shipment CAUTION The UPS is heavy see specifications Take proper precautions when lifting or moving it 2 Visually inspect the UPS for freight damage Report damage to the carrier and your dealer 3 Locate the UPS indoors where it cannot be accidentally disconnected Locate it in an area with unrestricted airflow away from water flammable liquids gases corrosives or conductive contaminants Maintain a minimum of four 4 inches 102 mm clearance around the UPS Maintain an ambient temperature range of 32 to 104 F 0 to 40 C NOTE UPS operation in temperatures above 77 F 25 C reduces battery life 4 Ensuring load equipment is turned off plug all loads into the UPS output receptacles 5 Plug the UPS into a dedicated wall receptacle properly protected by a circuit breaker or fuse in accordance with the National Electric Code ANSI NFPA 70 or local codes Use a 15 amp rated device for the 700 1000 or 1400 VA units and a 30 amp device for the 2200 VA unit The wall receptacle must be grounded 6 Turn on the UPS by pressing the On Off button then turn on the connected load equipment The UPS is ready for normal operation RACKMOUNT INSTALLATION 1 Unpack the UPS carefully noting the packing method Retain box and packing material for possible future shipment CAUTION The UPS is heavy see specification
12. URE INTERACTIVE MINI TOWER Fault Indicator PowerSeat INTERACTIVE Load Battery nore Level Indicators Utility High Low Indicator Utility Battery Status Indicator Alarm Silence Battery Test Button On Off Button Output Receptacles DB 9 Interface Port 1 AC Inlet Intellislot Communications Port Circuit Protector or Fuse Site Wiring Fault Indicator PERERIN 700 VA 1000 1400 VA 2200 VA 9 POWERSURE INTERACTIVE RACKMOUNT Fault Indicator Utility High Low Indicator Load Battery Utility Battery Level Indicators Status Indicator Alarm Silence Battery Test Button On Off Button 2200 Model 700 1400 Models 700 Model has detachable cord 1 Output Receptacles 2 DB 9 Interface Port 3 AC Inlet 4 Intellislot Communications Port 5 Circuit Protector or Fuse 6 Site Wiring Fault Indicator 10 OPERATION NORMAL MODE OPERATION During normal operation utility power provides energy to the UPS The filters and the power conditioning circuit process this power to provide computer grade power to connected loads The UPS maintains the batteries in a fully charged state The front panel displays the percentage of load on the UPS output The figure below indicates approximately 51 7596 loading 76 to 10096 load Flashes to indicate
13. a single flexible package Monitoring and control on site or remote from systems of any size or location Service and support through more than 100 service centers around the world and a 24 hour Customer Response Center world Specifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners SL 23550 2 98 Rev 5 0 27
14. d with stand alone computers network workstations network servers or UNIX hosts via the DB 9 female connector located on the rear of the UPS This capability is used in applications requiring the UPS to provide status and power monitoring information to the computer system For example during a utility power failure the information can be used by the computer s operating system or application program to automatically save information in buffers to close files and shut down operations prior to battery capacity depletion Monitoring of the UPS via a computer system is easily made with a Liebert SiteNet amp 1 shutdown kit sold separately Consult your local Liebert representative to determine the correct software kit for your application The kit includes special purpose cable and shutdown software UPS INTELLIGENT COMMUNICATIONS The PowerSure Interactive UPS has the capability to communicate intelligently with stand alone computers network workstations network servers or UNIX hosts via the DB 9 female connector located on the rear of the UPS By purchasing the optional Liebert SiteNet 2 software package sold separately intelligent communications allows the following capabilities Quantitative monitoring of utility and UPS power Quantitative monitoring of internal UPS parameters Periodic tests of battery quality and replacement notification Timed and delayed shutdown of the UPS Logging of power disturbances and anomal
15. ds into the UPS output receptacles 9 Turn on the UPS by pressing the On Off button then turn on the connected load equipment The UPS is ready for normal operation CONTROLS AND INDICATORS On Off Button The On Off button controls output power to connected load s CAUTION Pressing the On Off button when AC utility is not present will cause the UPS to begin operating from battery This should not be performed unless the UPS input is connected to a properly grounded receptacle Load Battery Level Indicators ALL GREEN The Load Battery Level Indicators have dual functions During normal mode operation LED indicators display electrical load placed upon the UPS and during battery mode operation LED indicators display battery capacity remaining Each LED designates a 25 load or battery capacity increment All four LED indicators illuminate at full load battery capacity If the UPS becomes loaded beyond full rating the top LED indicator will flash continuously while an alarm sounds Utility Battery Status Indicator GREEN An illuminated LED indicates the power button is on and utility power is available A flashing LED along with an alarm signifies utility voltage is out of specification and UPS is operating in battery mode Utility High Low Indicator AMBER An illuminated LED indicates the UPS is correcting utility power due to a utility overvoltage or undervoltage condition Fault Indicator GREEN The Fault indicator i
16. duct specified herein is originally installed for use in the United States the User This Warranty is not transferable or assignable without the prior written permission of Liebert Assignment of Warranties Liebert assigns to User any warranties which are made by the manufacturers and suppliers of components of the Liebert product and which are assignable but Liebert makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this Warranty to such components Descriptions Liebert warrants for the period and on the terms of the Warranty set forth herein that the product will conform to the descriptions contained in Liebert s final invoices orders and Liebert product brochures Liebert does not control the installation and use of any Liebert product Accordingly it is understood that the Descriptions are NOT WARRANTIES OF PERFORMANCE and NOT WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE Warranty Claims Procedure Within a reasonable time but in no case to exceed thirty 30 days after User s discovery of a defect User shall contact Liebert at 800 222 5877 and request a Return Authorization number User shall ship the product with proof of purchase to Liebert freight prepaid Liebert products shipped to Liebert without a Return Authorization number will be refused and returned
17. e cavity noting the white pull tabs are facing outward 8 700 1000 1400 VA models connect the battery wires first red to red then black to black 2200 VA models first connect top battery connector A to bottom battery connector A then connect UPS connector B to the top battery connector B NOTE There will be a small spark when connecting the black connectors on 700 1400 VA models and connector B on the 2200 VA model This is normal and will not harm you or the UPS 9 Replace battery door by inserting the two metal tabs into the slots at the base of the UPS and pushing it closed at the top Tighten the two screws to lock the battery door closed 10 Flip the bezel back into place and align bottom clips to the lower slots in the battery door Once aligned push bezel back onto the UPS until it latches into position This may require a gentle tap 11 Dispose Recycle of old batteries in accordance with your local laws and regulations 15 MINI TOWER BATTERY REPLACEMENT Pull bezel forward Rotate bezel on top Remove battery door 700 VA Model To Disconnect Gently pull wiring away To Connect Connect red wire to red terminal then black wire to black terminal by pushing towards connector 1000 1400 VA Model To Disconnect Gently pull wiring away To Connect Connect red wire to red terminal then black wire to black terminal by pushing upward 2200 VA Model To Disconnect Pull apart connec
18. es negligence inappropriate on site operating conditions corrosive atmosphere repair by non Liebert designated personnel accident in transit tampering alterations exposure to the elements Acts of God theft installation contrary to Liebert s recommendations or in any event if the Liebert serial number has been altered defaced or removed THIS WARRANTY DOES NOT COVER shipping costs installation costs circuit breaker resetting or maintenance or service items and further except as may be provided herein does NOT include labor costs or transportation charges arising from the replacement of the Liebert product or any part thereof or charges to remove the same from any premises of User THIS WARRANTY IS VOID if User allows the battery on the Liebert product to discharge below the minimum battery voltage cutoff point In order to prevent such discharge User should not leave the unit power in the On position for more than two 2 days without AC power being supplied to the Liebert product Also In order to guard against this discharge User must recharge the battery every six 6 months when the Liebert product is not in use REPAIR OR REPLACEMENT OF AND EXCLUDES ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Limitations THIS WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE USER S SOL
19. ies Contact your local Liebert representative dealer or reseller for more information about SiteNet 2 software UPS INTELLISLOT COMMUNICATIONS The PowerSure Interactive UPS contains an Intellislot communications port for the optional internal communications such as the Ethernet SNMP card Optional SiteNet amp SNMP Manager software is available to allow communication through several network management systems Contact your local Liebert representative dealer or reseller CAUTION TO MAINTAIN SAFETY SELV BARRIERS AND FOR ELECTROMAGNETIC COMPATIBILITY SIGNAL CABLES SHOULD BE SEGREGATED AND SEPARATELY RUN FROM ALL OTHER POWER CABLES WHERE APPLICABLE MAINTENANCE The PowerSure Interactive UPS requires very little maintenance The batteries are valve regulated nonspillable lead acid and require that they be kept charged to obtain their designed life Whether ON or OFF the UPS continuously charges the batteries when connected to the utility supply When storing the UPS for any length of time it is recommended to plug the UPS in for at least 24 hours every four to six months to ensure full recharge of the batteries The PowerSure Interactive UPS is designed to allow the user to safely replace the batteries Read the safety cautions before proceeding Contact your local Liebert representative dealer or reseller to obtain the appropriate replacement battery kit MINI TOWER BATTERY REPLACEMENT CAUTION
20. light emitting diode LED bar display to indicate load percentage or battery capacity depending upon the mode of operation It also provides self diagnostics a combination alarm silence battery test button and two levels of alarms when the unit is operating on battery The PowerSure Interactive has an interface port for communications between the UPS and a LAN server or other computer system This port provides detailed operating information including voltages currents and alarm status to the host system when used in conjunction with Liebert SiteNet software SiteNet software can also remotely control UPS operation CAUTION This equipment has been tested and complies with limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC rules These limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference which the user must correct at his own expense MAJOR COMPONENTS TRANSIENT VOLTAGE SURGE SUPPRESSION TVSS AND EMI RFI FILTERS These UPS components provide surge protection and filter Electromagnetic Interference EMI and Radio Frequency Interference
21. mation to determine whether external factors cause the problem and how to remedy the situation 1 The fault indicator will flash every second to indicate the UPS detected a problem An alarm will sound alerting that the UPS requires attention One or more additional load battery level LED segments will be illuminated to provide a diagnostic aid to the operator as described below D indicator Load Battery z Fault indicator flashes every second A indicator Utility High Low Utility Alarm silence Test e On Off e A UPS fault fan failure battery overcharge NOTE The internal fan operates intermittently as needed B UPS failed battery test D UPS shutdown due to output overload time out A amp B UPS shutdown due to main input relay failure output short circuit A amp D UPS shutdown due to over temperature condition B amp D UPS shutdown due to command from communication ports remote shutdown or SNMP The fault indicators will be illuminated indefinitely while battery charger is operational or for a maximum of 5 minutes while battery charger is not operational If a problem persists consult your dealer or contact Liebert Technical Support LTS World Wide Technical Support numbers are located at the end of this section TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION UPS fails to start when On Off button is pressed UPS output short circuited or overloaded
22. nt Such as idle computers and monitors WARNING Turning off the UPS while in battery mode will result in loss of output power The figure below displays approximately 51 75 battery capacity remaining 76 to 100 load Load Battery EM 5196 to 7596 load Level Indicators BE 26 to 50 load 0 to 25 load Flashes to indicate low battery Utility High Low Utility MEE Alarm silence Test e On Off e BATTERY RECHARGE MODE The UPS resumes normal operation once utility power is restored Atthis time the bi directional converter begins recharging the battery whether the UPS in ON or OFF COMMUNICATIONS INTERFACE PORT The PowerSure Interactive UPS contains a standard DB 9F recepticle located on the rear of the UPS unit Several signals are provided on this port and are assigned as follows PIN ASSIGNMENT DESCRIPTION 1 Low Battery open collector 2 UPS TxD typical RS 232 levels 3 UPS RxD typical RS 232 levels 4 Remote Shutdown 5 12V DC 1 0 mA max battery operation 5 Common 6 7 8 9 No connection Low Battery open emitter Utility Fail open emitter Utility Fail open collector Pin Assignment Collector to Emitter Open Collector 330 Ohms o Open Emitter Maximum voltage and current on pins 1 7 8 9 is 80V DC 10 0 mA UPS MONITORING The PowerSure Interactive UPS has the capability of being monitore
23. or replacement battery kit UPS shut down Fault indicator and diagnostic LED D are illuminated UPS overloaded or load equipment is faulty Check load level display and remove non essential loads Recalculate load VA and reduce number of loads connected to UPS Check load equipment for faults UPS shuts down with the Fault indicator and diagnostic LEDs A amp B are illuminated UPS shutdown due to internal failure UPS requires service Contact your dealer or LTS UPS shuts down with the Fault indicator and diagnostic LEDs A amp D are illuminated UPS shutdown due to an internal over temperature condition Ensure UPS is not overloaded ventilation openings not blocked or room ambient temperature not excessive Wait 30 minutes to allow UPS to cool then restart UPS If it does not restart contact your dealer or LTS UPS shuts down with the Fault indicator and diagnostic LEDs B amp D are illuminated UPS shutdown due to a command from the communications port s Your UPS has received a signal or command from the attached computer If this was inadvertent ensure the communication cable used is correct for your system For assistance contact your dealer or LTS 20 POWERSURE INTERACTIVE TYPICAL BATTERY DISCHARGE CURVES Discharge times are at 25 C ambient 1000 VA T T c E E c c 2 2
24. recautions To replace batteries refer to the battery replacement procedure If you feel unqualified to replace the batteries do not open the battery door Refer all servicing to qualified service personnel CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic INTRODUCTION amp SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure Interactive Uninterruptible Power System UPS It provides conditioned power to microcomputers and other sensitive electronic equipment Upon generation AC power is clean and stable However during transmission it may be subject to voltage sags spikes or complete power failure which may interrupt computer operations cause data loss or even damage equipment The PowerSure Interactive protects equipment from these disturbances The PowerSure Interactive comes in nominal power ratings of 700 1000 1400 or 2200 VA Complete specifications appear near the end of this section The PowerSure Interactive is a compact line interactive UPS A line interactive UPS continuously conditions and regulates its output voltage whether the utility power is present or not It supplies connected equipment with clean sinewave power to simulate as much as possible the power generated by the utility Sensitive electronic equipment operates best from sinewave power For ease of use the PowerSure Interactive contains a
25. ride in our products and are pleased that you have chosen them Under certain circumstances we offer with our products the following Two Year Warranty Against Defects in Material and Workmanship Please read your Warranty carefully This Warranty sets forth our responsibilities in the unlikely event of defect and tells you how to obtain under this Warranty TWO YEAR LIMITED WARRANTY AGAINST DEFECTS IN MATERIAL AND WORKMANSHIP The Liebert product is warranted to be free from defects in material and workmanship for a period of two 2 years from the date of product purchase If any part or portion of the Liebert product fails to conform to the Warranty within the warranty period Liebert at its option will furnish new or factory remanufactured products for repair or replacement of that portion or part Additionally if the Liebert product should fail to operate upon initial start up or should fail to operate upon initial start up or should cease to operate within ten 10 days of start up Liebert will provide User a new replacement product subject to the limitations below but at no cost to User for Liebert labor or transportation charges arising from the replacement of the product if Liebert determines the failure of the product was due to a defect in material or workmanship Warranty Extends to First Purchaser for Use Non transferable This Warranty is extended to the first person firm association or corporation for whom the Liebert pro
26. s Take the proper precautions when lifting or moving the UPS 2 Visually inspect the UPS for freight damage Report any damage to the carrier and your dealer 3 Locate the UPS indoors where it cannot be accidentally disconnected Locate it in an area with unrestricted airflow away from water flammable liquids gases corrosives or conductive contaminants Maintain a minimum of four 4 inches 102 mm clearance in front and rear of the UPS Maintain an ambient temperature range of 32 to 104 F 0 to 40 C NOTE UPS operation in temperatures above 77 F 25 C reduces battery life Gently lay UPS on its bottom side so that the front bezel is facing you 5 The Rackmount UPS must be supported by a shelf or rails The front bezel will not support the weight of the UPS CAUTION To increase the stability of the rack enclosure place the UPS in the lowest possible rack position 6 Refer to the Installation instructions supplied with the Rack Slide or Shelf Kits to complete the installation procedures 7 After the UPS has been installed in the Rack enclosure plug the UPS into a dedicated wall receptacle properly protected by a circuit breaker or fuse in accordance with the National Electric Code ANSI NFPA 70 or local codes Use a 15 amp rated device for the 700 1000 or 1400 VA units and a 30 amp device for the 2200 VA unit The wall receptacle must be grounded 8 Ensuring load equipment is turned off plug all loa
27. s the second uppermost LED contained in load battery level indicators A flashing LED indicates the UPS has detected a problem An alarm sounds to alert that the UPS requires attention Refer to Troubleshooting Guide Alarm Silence Battery Test Button The Alarm Silence Battery Test button serves a dual purpose During normal mode operation press button for at least one half second to test capacity of the battery system The UPS will operate in battery mode for approximately 15 seconds The illuminated LED indicators in Load Battery Level determine battery mode capacity in 25 increments During battery mode operation or active alarm condition this button functions as the alarm silence feature Pressing this button for at least one half second will silence the alarm After the alarm is silenced the PowerSure Interactive will reactivate the alarm system to alert of additional problems The low battery alarm is the single alarm that cannot be silenced During a Battery Test if the top two LEDs do not illuminate allow the UPS to recharge the batteries for 24 hours After 24 hours retest the batteries If the batteries have been retested and the top two LEDs still do not illuminate contact your dealer or Liebert Technical Support LTS for a battery replacement kit Site Wiring Fault Indicator RED An illuminated LED indicates the UPS has detected a miswired utility receptacle Contact a qualified electrician for assistance POWERS
28. t matter herein and supersedes all prior or contemporaneous oral or written communications representations understandings or agreements relating to this subject 26 O Lieber 1050 Dearborn Drive Columbus OH 43229 614 888 0246 PowerSure Interactive 700 2200 VA 120 V Technical Support US AL 1 800 222 5877 PAS 614 841 6755 44 0 1793 553355 4331487 5152 Germany 49 89 99 19 220 Italy 39 2 98250 1 Netherlands eorr rentes 00 31 475 503333 Interne rne nime etre ee nee tiere ds upstech liebert com Webssite nnne http Awww liebert com Worldwide FAX Tech Support 614 841 5471 The Company Behind The Products While every precaution has been taken to ensure Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions With more than 500 000 installations around the globe Liebert is the world leader in computer protection systems Since its founding in 1965 Liebert has developed a complete range of support and protection systems for sensitive electronics Environmental systems close control air conditioning from 1 5 to 60 tons Power conditioning and UPS with power 1998 Liebert Corporation All rights reserved throughout the ranges from 250 VA to more than 1000 kVA Integrated systems that provide both environmental and power protection in
29. tached w NEMA 5 15 P NEMA 5 15 P NEMA 5 15 P NEMA L5 30 P OUTPUT AC PARAMETERS Output Receptacles 6 5 15R 125208 103 VAC to 132 VAC Max Current Rating 5 8 A 18 3A Frequenc 50 Hz or 60 Hz Waveform Sinewave Utility Mode Overload 200 for gt 2 cycles 110 for gt 5 minutes Battery Mode Overload 150 for gt 1 cycle 110 for gt 30 seconds BATTERY PARAMETERS Type Valve regulated nonspillable lead acid Qt x Voltage x Rating 2 x 12V x 7 0 or 7 2 AH 3 x 12V x 7 0 or 7 2 AH 4 x 12V x 7 0 or 7 2 AH 8 x 6V x 12 AH Batt Mfg Part Number CSB GP1270F2 or Panasonic LC R127R2CH1 Panasonic LC R0612CH1 Transfer Time 2 6 ms typical Back up Time See Typical Battery Discharge Curves Recharge Time 3 Hours to 95 capacity after full discharge into 100 load ENVIRONMENTAL Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 5 F to 122 F 15 C to 50 C Relative Humidit 0 to 95 non condensing Operating Elevation Up to 10 000 ft 3000 m at 35 C without derating Storage Elevation 50 000 ft 15 000 m maximum Audible Noise lt 45 dBA at 1 meter AGENCY Safety RFI EMI Immunity UL 1778 c UL Listed FCC Part 15 Subpart B Class A IEC 801 2 Level 4 IEC 801 4 Level 4 IEEE 587 Category A 24 LIMITED WARRANTY Liebert Corporation and its division Emerson computer power herein Liebert manufacture in our opinion the finest systems and products available We take p
30. tions A amp B To Connect Push connections A together amp connections B together 16 RACKMOUNT BATTERY REPLACEMENT CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed before replacing the batteries e Turn off and disconnect the UPS from utility power prior to opening the battery replacement door Remove rings watches and other metal objects Use a Phillips cross head screwdriver with insulated grips Do not lay tools or other metal objects on top of the batteries If the battery replacement kit is damaged in any way or shows signs of leakage contact your dealer immediately e Do not dispose of batteries in a fire the batteries may explode If you feel unqualified to replace the battery do not open the battery door Call Liebert Technical Support LTS World Wide Technical Support numbers are located at the end of this section 1 Using a Phillips cross head screwdriver loosen the 4 screws around the battery door as in Figure 1 Carefully remove the battery door by pulling it forward Lay the battery door and screws aside for reassembly 2 Again using a Phillips cross head screwdriver loosen the 4 screws holding the battery retaining plate as in Figure 2 Carefully remove the battery retaining plate by pulling it forward Lay the battery retaining plate and screws aside for reassembly 3 700 1000 1400 VA models Gently
31. tions before operating the UPS Adhere to all warnings on the unit and in this manual Follow all operating and user instructions 6 Turn the UPS off and unplug it before cleaning Use only a soft cloth never liquid or aerosol cleaners 7 The UPS is designed for data processing equipment Do not plug appliances such as hair dryers heaters vacuum cleaners or electric drills into the UPS output receptacles 8 WARNING Do not modify input cable Consult your dealer if connector does not match the utility receptacle The UPS must be grounded at all times while in use Turn the UPS off before unplugging 2 10 11 12 13 it or the safety ground will be removed Operate UPS only from a properly grounded 120 VAC outlet 2 wire plus ground The UPS is equipped with a grounded NEMA 5 15P or L5 30P input power plug depending upon model Do not defeat the safety purpose of this plug If unable to fully insert the plug into the wall outlet contact a qualified electrician for assistance Route power supply cords so they are not walked on or pinched Never block or insert any object into the ventilation holes or other openings Maintain a clearance of four 4 inches 102 mm around the UPS for proper air flow and cooling Always turn off the UPS and unplug it before starting the battery replacement procedure Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required p
32. to the input AC supply 6 Restart the UPS The UPS is ready for normal operation NOTE For 1000 1400 and 2200 VA units press the reset circuit protector button 22 MINI TOWER SPECIFICATIONS Model Number PS700MT 120 PS1000MT 120 PS1400MT 120 PS2200MT 120 Model Rating VA W 700 450 1000 670 1400 950 2200 1600 Unit WxDxH 5 5 x 14 4 x 6 8 x 17 5 x 6 8 x 17 5 x 7 6 x 20 1 x 7 0 140 x 365 x 8 9 172 x 447 x 8 9 172 x 447 x 13 2 194x511 x 178 227 227 336 Shipping W x D xH 10 5 x 19 2 x 12 0 x 22 25 x 14 12 0 x 22 25 x 14 13 0 x 25 0 x 11 75 265 x 492 307 x 581 x 358 307 x 581 x 358 18 5 330 x 635 x x 300 470 WEIGHT Ibs kg Unit 29 9 13 6 43 4 19 7 49 4 22 5 81 7 37 1 Shipping 33 1 15 0 46 5 21 1 52 5 23 9 87 0 39 5 INPUT AC PARAMETERS Voltage Range 120 VAC 25 23 Voltage Raise Maintains output to 120 VAC 14 when input is 120 VAC 25 Voltage Lower Maintains output to 120 VAC 10 when input is 120 VAC 23 Frequency 45 55 Hz or 55 65 Hz auto sensing OUTPUT AC PARAMETERS 103 VAC to 132 VAC Frequency 50 Hz or 60 Hz Waveform Sinewave Utility Mode Overload 200 for gt 2 cycles 110 for gt 5 minutes Battery Mode Overload 150 for gt 1 cycle 110 for gt 30 seconds BATTERY PARAMETERS Type Valve regulated nonspillable lead acid Qt x Voltage x Rating 2 x 12V x 7 0 or 7 2 AH 3 x 12V x 7 0 or 7 2 AH 4 x 12V x 7 0 or 7 2 AH 8 x 6V x 12 AH Batt Mfg Part Number CSB GP127