Home

User manual

image

Contents

1. DEVICE CONSTRUCTION IR Sensor LCD Display Mode selection body ambient Down Button Up Button MODE Button Measurement Trigger Battery Cover eer SY 8 CONFIGURATION I Measuring mode The Non contact Body Infrared Thermometer is specially designed to take the body temperature of ahuman being For this use the Body mode Measurement range for Body mode 32 42 5 C 86 108 F You can also use the thermometer to measure the temperature of an area or an object food liquid or room temperature For this use the Surface mode Measurement range for Surface mode 0 60 C 82 140 F ll Choosing The Temperature Unit C F Fl function Press MODE button for 2 seconds the screen displays F1 Select DOWN for Celsius degrees or UP for Fahrenheit degrees lll Alarm Setup F2 Menu Press MODE touch for 2 seconds the screen displays F1 Press twice MODE touch to get F2 Select UP to increase the threshold by 0 1 C 0 1 F or DOWN to deuce it by 0 1 C 0 1 F The alarm threshold default is 38 C 100 4 F IV Pyrometer display calibration Total Difference This function is only effectictive in Body mode body temperature measurement To adjust the total variation of your Non Contact Body Infrared Thermometer press MODE button for 2 seconds the screen displays F1 Press MODE button two times to get F3 Select UP to increase the d
2. 3 C range Dimensions weight 128x74x36 mm 125g Power supply DC 3V 2 x 1 5V battery Operation environment 0 C 50 C lt 85 RH Equipment batteries case user manual This appliance conforms to the following standards EN 980 Graphic symbols for use in the labeling of medical devices EN 1041 Information supplied by the manufacturer with medical devices EN 60601 1 General requirements for safety EN60601 1 2 General requirements for safety Collateral standard Electromagnetic compatibility 3 USE Aim towards the forehead from a distance of 5 cm 2in press the measuring key the temperature is displayed immediately Making sure there is no hair perspiration cosmetic or cap covered on the forehead When the room temperature is significant difference or there is perspiration on the forehead You can take the temperature behind the ear lobe Making sure there is no hair perspiration cosmetic or cap covered Attention For the first use or when inserting new batteries wait between 10 minutes for the warm up of the apparatus and when inserting the new batteries If the device is not used for a long time once you turn it on again the device will test the room temperature first and will delay turning on for one or two seconds 4 BODY TEMPERATURE MEASUREMENT BODY Body temperature measuring range is 32 0 C 42 5 C If the measurement value is not within a range the display can indicates following communic
3. ates HI when the temperature exceeds 42 5 C Lo when the temperature is below 32 0 C The temperature of the human body varies throughout the day It can also be influenced by numerous external factors age sex type and thickness of skin Temperature according to the age 0 2 years 36 4 C 38 0 C 3 10 years 36 1 C 37 8 C 11 65 years 35 9 C 37 6 C gt 65 years 35 8 C 37 5 C Normal temperature in different parts of body Forehead 35 5 C 37 6 C Ear 35 8 C 38 0 C Oral 35 0 Gi 07 0 C Axilliary 34 7 C 37 3 C 5 DISPLAY Ii Surface wer 1 Ambient temperature measurement 3 Body 2 Body temperature measurement 3 Digital readout W 4 Battery Condition E g 5 Measurement number 3 6 Saved measurement E i 7 Unit 8 Alarm Symbol 9 BAAR 6 DATA READOUT Turn on the unit with button no 7 measurement trigger Then pass between the stored data pressing 3 or 4 button
4. ifference by 0 1 C 0 1 F DOWN to reduce it by 0 1 C 0 1 F Temperature value can be changed in 3 0 3 0 C range In the cases of seasonal or environment changes a verification and adjustment should be carried out V BuzzerON OFF F4 F3 Menu Press MODE button for 2 seconds the screen displays F1 Press three two times MODE Button to get F4 F3 Select UP to open the buzzer asound icon is displayed on the LCDC screen press DOWN to stop it the icon dissapear es L termoplus ROZWI ZANIA W AUTOMATYCE DT 8806 PYROMETER Version 2 0 USER MANUAL WARRANTY 1 GENERAL DESCRIPTION Non Contact Forehead IR Thermometer is designed for body surface and forehead temperature measurement for infants and adults without contact to human body Non Contact Forehead IR Thermometer can also be used to measure the temperature of a baby bottle or bath or room temperature by using the Surface Temp function 2 TECHNICAL SPECIFICATIONS Pyrometer measuring range ambient temperature 0 0 60 0 C body temperature 32 0 42 5 C Display Resolution 0 1 C Accuracy 0 3 C Measuring distance 5 15cm Display LCD with backlight Automatic Data Hold amp Auto power off after 7 sec of idleness Unit selection C F Buzzer indicating about a measurement and alarm threshol exceeding Functions last 32 measurements memorizing measurements calibration in 3

Download Pdf Manuals

image

Related Search

Related Contents

Andis Company HDB-1 User's Manual  平成元年神審第100号 貨物船第二栄勢丸機関損傷事件 〔簡易〕 言渡年  MAC® 5500 Resting ECG Analysis System  ASROCK P4S61 User Manual  取扱説明書・AST-4GB (PDFファイル  ELISA IgM HEV - MP Biomedicals  IM EH99834401 MMD-APxxx1BH SMMS  Hama uRage    Liebherr HC-1060 Premium Plus Series 24" Built-in Fully  

Copyright © All rights reserved.
Failed to retrieve file