1. system or recharged directly in the system As over discharging will shorten the working life of the battery it should be charged in time when the display shows L on the highest bit representing low battery The battery should be recharged by 220V 50Hz power supply for about 8 hours Auto shutoff When no operation is exerted on the indicator over one hour it will automatically shut off power supply The indicator backlight will automatically turn off when no operations are performed in 30 seconds The light automatically recovers if the keys are pushed or the scale begin to hoist weights The indicator will automatically shut off in 30 minutes when no operations are exerted Maintenance 1 The electric crane scale is a high precision instrument Good and thoughtful maintenance can raise its reliability which is very important to elongate its service life 2 Although the scale body is proof to water and impacts it should be protected from strong impacts and rain for a long time Pay attention that the scale does not falls from the hook to suffer a violent hit or cause accidents 3 Unless the scale is specially designed to work in high temperature do not leave it in such an environment for too long a time It is worth mentioning that if the scale works all right if the enclosure does not feel too hot less than 70 4 It is prohibited to perform welding on the scale surface to protect the indicator and load cells 5 N
2. OCS XS F1 Crane Scale User s Manual Summary The OCS XS wireless crane scale uses dedicated load cell of high precision and 2 A A D converter based on most advanced technology With the RF and single chip computer technology combined this series provides extreme reliable accuracy and complete software function From time to time we raise performances of our products therefore please be kindly advised that the actual use of custom products may differ from that mentioned hereby Features LCD display with backlight makes it clear to read either in the daylight or at night Small sized indicator provides portability Weighing results are classified into as many as 256 groups statistics and printing can be performed for each category Built in character printer Print out date and category on the report Memorize as many as 2730 weighing records Weight units kg Ib switch 9 The clock and calendar are built in with time and date reliability Auto power shutoff when the scale remains static over one hour Two way data transmission If the indicator is used in the crane scales of OCS XZ series and digitalized the scale the indicator is then capable of not only receiving data but also remote controlling it in tare and other function set up Major technical indexes 1 Accuracy compliant to OIML III standard 2 Battery supply 6V 4AH 3 Radio frequency 430MHZ or 450MHZ 15 frequency points e
3. ach 4 Displayed refreshing rate 5 times sec 5 Excited voltage of load cell DC 5V 5 6 Operating temp Indicator 0C 40C scale body 30 C 70C 7 Continual working hours of scale body per charging 40 hours 8 Unobstructed wireless transmission distance 200 meters Pane XK3196F1 portable wireless Weighing Indicator LCD display ZERO WGHTMS TOTAL STORE STAB LOWVTG SGNL Micro printer Functions of keys ONI power on OFF power off ZERO display 0 TOTAL to display total weight also used in report printing REQ to recall weighing results displaying in reversed turn F1 auxiliary key BLIGHT ON OFF key of the LCD display backlight it is economical to turn it off in strong light situations T C TTL CLR push this key 2 times and all the records are cleared DEL push this key 2 times and the last weighing record is cleared SUM push this key when the weighing is finished the indicator will then start printing out a summary report on weighing of the current category AUTO entry into auto the auto status when the highest bit of the display is A the indicator will automatically put results of each weighing into memo and print it out to exit AUTO push this key again C N to recall the weighing times concerned in the memo CLASS to set the category No 0 255 T S TARE SET to set tare DATE date set TIME time set STORE to st
4. ever overload the scale 6 To elongate the service life of batteries it is better to turn off the backlight in the daylight 7 The weighing system uses lead acid accumulators that should not be over discharged 8 Protect the display from rain 10
5. hing result and prints it out after the scale stable for 4 seconds The time period can be set therefore please request to our suppliers if need be 2 Feeding paper to the printer As it is quite complicated to feed paper to the printer therefore new users could seek advice with local suppliers Step 1 Shut off the power supply and discover the covering plate of the printer Step 2 Loose the screw that fix paper and take out Step 3 Insert paper to the paper feeding slot power on the machine and push SUM The printer then automatically feeds paper Step 4 Cover the plate on the printer 3 Time display set up The indicator has a built in clock Push TIME to enter into set up status After setting up the real time push it again to conform it otherwise push TIME to exit it directly E g to set time 12 08 20 the operator should input 120820 0 between the hour and minute should not be omitted The clock loses less than 1 second per day 4 Date display set up A calendar is built in the indicator Push DATE to enter into set up After setting up the date push the key again to conform it Otherwise exit set up directly by pushing DATE again E g input 020328 for the date March 28 2002 The built in clock and calendar reporting is not subject to the influence of power on off 5 Recharging The scale body and indicator are battery supplied and should be charged respectively with the batteries either unloaded from the
6. o delete the last weighing record push DEL and the display reads Clr If need be push DEL again to conform it Note The records will not be lost at power off unless the above operations are operated 3 Report printing This function works in some occasions that re printing is called for A variety of combined statistical methods are provided 1 Summary report printing Push TOTAL two times successively and the printer will print out reports on all the weighing recorded E g WEIGH BILL TOTAL 5245kg 003 15 12 2101 002 08 59 1806 001 08 57 1338 2 Classified summary reports printing To print a classified report the operator must set up class before hands refer to CLASS SET Push TOTAL and then push CLASS so that the lowest bit on the display shows H After that push TOTAL once again and the printer start printing The format is as follows WEIGH BILL CLASS 05 DATE 2002 07 12 TOTAL 5245kg SUM 0003 NO TIME NW kg 003 09 12 2101 002 08 59 1806 001 08 57 1338 3 Date summary report printing It is unnecessary to set up date printing on the same date otherwise refer to DATE setting Push in turn the keys TOTAL DATE and TOTAL The printer then prints out a report of weighing in a day The printing format is as follows WEIGH BILL DATE 2002 07 12 TOTAL 5245kg SUM 0003 NO TIME NW kg 003 09 12 2101 002 08 59 1806 001 08 57 1338 Note Once the date se
7. onform it 4 Weighing To weight an object the operator should suspend it on the hook and read the data shown on the display The net weight is available by putting the unpacked object on the hook and push ZERO 5 Store up and print out the weighing result After the object is suspended and stabilized push STORE to record the weight at the same time add 1 to the list No The indicator will then print out the weighing result The format is as follows 001 08 57 2352 It is only effective to push STORE to record one weighing result Repeat the above operations pushing STORE after suspension and the indicator automatically prints out a second result as follows 002 08 59 1806 For a summary report for several consecutive weighing push SUM and a heading will be added automatically The format is as follows WEIGH BILL DATE 2000 08 18 CLASS 09 TOTAL 1358kg SUM 0021 NO TIME NW kg 0021 09 57 2202 0020 09 53 1906 0001 08 56 2352 6 Memory display The built in memory can store up to 2730 records Push REQ to check the weighing records When the memory is used up delete records in time by pushing T C two times 7 Clear up the memory It is necessary to clear up the memory when little space is left or the recorded data is out of date Push T C and the display reads Clr Push T C a second time to conform the above operation if need be 8 Clear up the latest record When the operator intends t
8. ore up the weighing result and print it out CE PRINT to clear the incorrect input Operational directions of indicators 1 Turn on Turn on the scale body before the indicator is on 1 After turning on the device the display reads in turn the software edition No e g 1 0 and maximum capacity Afterwards it counts in reverse turn to 11111 and the display will remain the same reading unless it receives a radio signal 2 If the radio signals come steady and the display reads 0 it is ready to work 2 Weighing operations An operator only needs to push ZERO in the event that printing is unnecessary Simple printing operation In auto status the indicator automatically records and printing the result out when the scale is stable In manual status the operator only needs to push STORE to accomplish recording and printing If the classified statistical function is called for set up the category before weighing 1 ZERO If it is necessary to set tare push ZERO so that the display reads 0 and the light on the bit turns on 2 TARE SET This function is applied when the tare weight is already known Push T S and the display window shows P 0 Then push T S again It is unnecessary to input decimal point e g input 31505 instead of 3150 5kg 3 Set up class NO Push CLASS to display the original class No If the No is not to be changed push CLASS again otherwise input a new No and then Push CLASS to c
9. t is changed make sure to re set it to report the actual date 4 Multi parameters report printing Sometimes multi classified printing is required e g to print out weighing report of one category in a day We thus offer this function which once appeared only in weighing systems that worked with a computer Set up the parameters required and push TOTAL PARAMETER 1 PARAMETER 2 and TOTAL again For instance to print out a report on the weighing operated by Mr Zhang on August 18 2002 with the class No 07 The parameters involved are class No and date Therefore the operational steps are as follow class NO set up push CLASS 07 and CLASS again DATE set up push DATE 020818 and DATE again Input classified statistical commands TOTAL CLASS DATE and TOTAL 5 Recall weighing results printing This function is set to recall weighing history and re print reports in reversed turn Push REQ and the indicator will display net weights recorded Push PRINT to print those records out Push REQ to check the next weighing result At the end of the memory the display will designate End Push ZERO to exit recalling 4 Other operate 1 Auto storing up It is optional to set up auto storing up After pushing AUTO and the highest bit on the display reads A the indicator enters into AUTO status The indicator exits AUTO status if AUTO is pushed again or it is powered off In the AUTO status the indicator automatically records the weig

Download Pdf Manuals

image

Related Search

Related Contents

Zoar Residential Home Service User Guide  DICENTIS - Bosch Security Systems  Toshiba 1000 & 1000+ UPS User`s Manual  petSCAN RT100 User guide  Motorola SX700R 12-Mile FRS/GMRS Radio Walkie Talkie NIMH SX700  J, K, Z AND TWIN MANIFOLD VALVES  Samsung 12I-RAC Wall-mount with Good Sleep Mode, 3.516 kW User Manual  Configuring and Troubleshooting Windows  cerec ac - Sirona Support  Telenetics 2185 User's Manual  