EAZY-RL V1
Contents
1. 30mm 37mm Figure 1 operate upper limit lower limit voltage correction LED shut down time Connect to power LED digital tube displays voltage value by detect from voltage Interface Figure 1 short press SET button to setting the value to be SET flashing press the ENTER button can make the set value from 0 to 9 increasing circulation first is to be set the upper limit voltage values short press SET three times the second group is set the lower limit voltage values voltage lower limit values setting could not be beyond the upper limit values if the lower limit values cannot be set please set the upper limit values higher first short press SET button to enter the third set of values for the voltage correction the default is 0 set the range of 0 5 0 5 V the fourth set of values for the digital tube automatically shut down time such as dl0 means digital tube has been bright dl9 means digital tube shut down after nine minutes press SET after the completion of the set digital tube are no longer flashing at this time into voltage detection control state real time display of external input DC voltage value when detecting the voltage exceeds the upper limit value when the voltage the relay close normally open on normally closed off until the voltage is drop lower than the voltage lower limit relay to release normally closed connected norma
2. EAZY V3 Controller User s Manual Thank you for using this product of our company the EAZY V3 controller uses the LED digital tube displays procedures for intelligent control to achieve the voltage control function and voltmeter functions battery charge and discharge etc In case of any printing or translation error we apologize for the inconvenience Features Voltmeter display range DC 0 99 9 V Voltage detection error 0 1V Operating Power DC10 16V Timer Range 0 999 minutes Relay parameters Coil Voltage DC 12V A set of conversion normally open and normally closed Contact load 10A 277V AC or 10A 30V DC Contact resistance lt 100mQ 1A 6VDC Mechanical durability 10 millions Electricity durability gt 100 000 10A 250VAC Operating Temperature 40 85 C Set display shut the minimum current values are 6mA 12V delay released The pre set parameters can be saved after power off Attention Do not reverse input voltage polarity Use this product to control the high voltage electrical equipment must electrical professionals to operate high voltage danger LOAD POWER AC DC NC Normally closed contact of relay LOAD NO Normally open contact of relay COM Common terminal TIo Input signal to force relay close voltage NC COM NO INPUT f o Short circuit 1 amp 2 switch to the switch input Se ae Short circuit 2 amp 3 switch to 5 16V input 2 3 Controller power
3. lly open off If the pre set voltage upper and lower limits values set to the same such as 12 0V when controller detected voltage values at 12 0 fluctuations may cause the relay contact frequent action We recommend to set the voltage to maintain the difference between the upper and lower limits The factory default setting is relay closed for a voltage exceeding the upper limit the relay released when the voltage is below the lower limit if you want the voltage below the lower limit relay close you can press the SET button for three seconds then release the button the contact of relay state will be reverse Detecting voltage condition short press the ENTER can display the state of the relay closing timer decimal point right flashing means timing when the relay release time to stop when relay close again will time in timing process can be long press ENTER for 3 seconds to reset value Switch pulse input terminals can be an external switch or voltage signals 5 16 v to force control relay close when external switch or continuous voltage signal input relay close when the switch or signal disappears relay controlled by the voltage detection Note The detection voltage terminal access to reliable have not loose wiring around the circuit board insulation may lead to the induced voltage detection values is not accurate
Download Pdf Manuals
Related Search
Related Contents
16-port 1 user IP USB/PS2 KVM Switch CS1716i Télécharger le document MVS 20 USER MANUAL - Minipack Help Center AIR COMPRESSOR Compresor de aire Compresseur d`air Punto Top-Plus-RoboStar inglese Rosewill RCW-H9011 Philips DM4S6S10F ®OO - hama.com LB DVR User's manual Copyright © All rights reserved.
Failed to retrieve file