1. Set value is added or subtracted to actual measured value by sensor Available configuration parameters data type is 2 Byte DEC e default value 32536 e 32536 offset is 0 0C e From 1 to 100 value from 0 1 C to 10 0 C is added to actual measured temperature e From 1001 to 1100 value from 0 1 C to 10 0 C is subtracted to actual measured temperature Parameter no 120 Digital temperature sensor reporting If digital temperature sensor is connected module reports measured temperature on temperature change defined by this parameter Available configuration parameters data type is 1 Byte DEC e Default value 5 Temperature is reported on 0 5 C change e 0 Reporting disabled e 1 127 0 1 C 12 7 C step is 0 1 C Technical Specifications 50 60HZz 24 30VDC output resistive load Rated load current of DC 1 X 10A 30VDC output resistive load Output circuit power of 2300W 230VAC AC output resistive load Output circuit power of 240W 24VDC DC output resistive load Digital temperature 50 125 C sensor range Sensor must be ordered separately Operation temperature 10 40 C Distance up to 30 m indoors depending on building materials Dimensions WxHxD 41 8x36 8x15 4mm package 79x52x22mm 28g 34g Electricity consumption For installation in boxes 2 60mm or 2M Switching Weight Brutto with package In case of load other
2. than resistive pay attention to the value of cos and if necessary apply load lower than the rated load Max current for cos o 0 4 is 3A at 250VAC 3A at 24VDC L R 7ms Z Wave Device Class BASIC_TYPE_ROUTING_ SLAVE GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Z Wave Supported Command Classes COMMAND_CLASS_ ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_ MANUFACTURER_SPECIFIC COMMAND_CLASS_ POWERLEVEL COMMAND_CLASS BASIC COMMAND_CLASS_SWITCH_ALL COMMAND_ CLASS _ SWITCH_BINARY COMMAND_CLASS_ SENSOR_MULTILEVEL_V7 COMMAND_CLASS_ MULTICHANNEL _V2 COMMAND CLASS ASSOCIATION COMMAND_CLASS_ CONFIGURATION COMMAND_CLASS_ MANUFACTURER_SPECIFIC COMMAND_CLASS_VERSION COMMAND_CLASS_ MARK COMMAND_CLASS _ BASIC COMMAND _ CLASS SWITCH_BINARY Endpoint 1 COMMAND_CLASS_ ZWAVEPLUS_INFO COMMAND_CLASS_ VERSION COMMAND_CLASS_ MANUFACTURER_SPECIFIC COMMAND_CLASS_ POWERLEVEL COMMAND_CLASS _ BASIC COMMAND_CLASS_ SWITCH_ALL COMMAND_CLASS_ SWITCH_BINARY COMMAND CLASS SENSOR_MULTILEVEL_V7 COMMAND_CLASS_ ASSOCIATION COMMAND _CLASS_ CONFIGURATION COMMAND_CLASS_ MANUFACTURER_SPECIFIC COMMAND_CLASS_ VERSION COMMAND_CLASS_ MARK COMMAND_CLASS _ BASIC COMMAND _CLASS_ SWITCH_BINARY Endpoint 2 12 Device Class GENERIC_TYPE_SENSOR_BINARY SPECIFIC_TYPE_NOT_ USED Command Classes COMMAND_CLASS_ SENSOR_BINARY COMMAND_CLASS BASIC This product can be included and operated in any Z Wave network with other Z Wave certified d
3. D relay module does not save the state after a power failure it returns to off position Parameter no 63 Output Switch selection Set value means the type of the device that is connected to the output The device type can be normally open NO or normally close NC Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 When system is turned off the output is OV NC e 1 When system is turned off the output is 230V or 24V NO Parameter no 80 Reporting to controller This parameter defines if reporting regarding power level multilevel etc are reported to controller or not Available configuration parameters data type is 1 Byte DEC e Default value 1 e 0 reporting to controller is disabled e 1 reporting to controller is enabled NOTE Disabling reporting is recommended in case Z wave modules communicate in association groups without using main controller Parameter no 100 Enable Disable Endpoint 2 Enabling 12 means that Endpoint 12 will be present on UI Disabling it will result in hiding endpoint according to parameter set value Note that hiding endpoint has no impact on it functionality Available configuration parameters data type is 1 Byte DEC e default value 1 e 1 Endpoint 12 enabled e 0 Endpoint 12 disabled NOTE After parameter change module has to be reconfigured Parameter no 110 Temperature sensor offset settings
4. Qubino The INNOVATIVE and SMALLEST Flush 1D relay ORDERING CODE Z WAVE FREQUENCY ZMNHND1 868 4 MHz ZMNHND2 921 4 MHz ZMNHND3 908 4 MHz ZMNHND4 869 0 MHz ZMNHND5 916 0 MHz This Z Wave module is used for switching on or off the electrical device e g light fan etc The module can be controlled either through Z wave network or through the wall switch The module is designed to be mounted inside a flush mounting box hidden behind a traditional wall switch Module supports connection of digital temperature sensor It is designed to act as repeater in order to improve range and stability of Z wave network Supported switches Module supports mono stable switches push button and bi stable switches The module is factory set to operate with bi stable switches Installation e Before the installation disconnect power supply e Connect the module according to electrical diagram e Locate the antenna far from metal elements as far as possible e Do not shorten the antenna Danger of electrocution e Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician e Even when the module is turned off voltage may be present on its terminals Any works on configuration changes related to connection mode or load must be always performed by disconnected power supply disable the fuse Note Do not connect the module to loads exceeding recommende
5. d values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Package contents e Flush 1D relay Electrical diagram 230VAC Option for different load power supply DPLS L N Notes for the diagrams N Neutral lead L Live lead QA _ Input for electrical device power supply QB Output for electrical device 12 Input for switch push button or sensor l1 Input for switch push button TS Terminal for digital temperature sensor only for Flush 1D relay module compatible digital temperature sensor which must be ordered separately Electrical diagram 24VDC Option for different load power supply DPLS Notes for the diagrams N VDC L VDC QA _ Input for electrical device power supply QB Output for electrical device 12 Input for switch push button or sensor l1 Input for switch push button TS Terminal for digital temperature sensor only for Flush 1D relay module compatible digital temperature sensor which must be ordered separately Note Output contact is voltage free dry contact so also loads with different power supply can be connected to the module S Service button used to add or remove module from the Z Wave network Durability of the module depends on applied load For resistive load light bulbs etc and 10A current consumption of each individual electrical device the durability exceeds 100 000 switches of each indi
6. evices from any other manufacturers All constantly powered nodes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network Important disclaimer Z Wave wireless communication is inherently not always 100 reliable and as such this product should not be used in situations in which life and or valuables are solely dependent on its function Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to change and improvement without notice NOTE User manual is valid for module with SW version S1 SW version is part of P N Example P N ZMNHNDx H1 1P1 CE X Qubino Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info qubino com Tel 386 5 335 95 00 Web www qubino com Date 06 05 2015 Document Qubino_Flush 1D relay PLUS user manual_V1 0_eng
7. from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e Default value 0 e 0 Auto OFF disabled e 1 32535 1second 0 01s 32535 seconds 325 35s Auto OFF enabled with define time step is 1s or 10ms according to parameter nr 15 Parameter no 12 Automatic turning on output after set time When relay is OFF it goes automatically ON after time defined by this parameter Timer is reset to zero each time the module receive OFF command regardless from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e Default value 0 e 0 Auto ON disabled e 1 32535 1second 0 01s 32536 seconds 325 35s Auto ON enabled with define time step is 1s or 10ms according to parameter nr 15 Parameter no 15 Automatic turning off on seconds or milliseconds selection Available configuration parameters data type is 1 Byte DEC e Default value 0 e 0 seconds selected e 1 milliseconds selected NOTE This parameter is valid for both turning on and turning off parameters Parameter no 30 Saving the state of the relay after a power failure Available configuration parameters data type is 1 Byte DEC e default value 0 e 0Q Flush 1D relay module saves its state before power failure it returns to the last position saved before a power failure e 1 Flush 1
8. oller to other Z Wave modules Associated Groups Group 1 default reporting group reserved for the main controller Group 2 basic on off triggered at change of the output state and reflecting its state up to 16 nodes Group 3 basic on off triggered at change of the input 12 state and reflecting its state up to 16 nodes Configuration parameters Parameter no 1 Input 1 switch type Available configuration parameters data type is 1 Byte DEC e default value 1 e 0 mono stable switch type push button e 1 bi stable switch type Parameter no 2 Input 2 contact type Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 NO normally open input type e 1 NC normally close input type Parameter no 10 Activate deactivate functions ALL ON ALL OFF Available configuration parameters data type is 2 Byte DEC e default value 255 e 255 ALL ON active ALL OFF active e 0 ALL ON is not active ALL OFF is not active e 1 ALLON is not active ALL OFF active e 2 ALLON active ALL OFF is not active Flush 1D relay module responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controller belonging to the system Parameter no 11 Automatic turning off output after set time When relay is ON it goes automatically OFF after time defined by this parameter Timer is reset to zero each time the module receive ON command regardless
9. vidual electrical device Module Inclusion Adding to Z wave network e Connect module to power supply with temperature sensor connected if purchased e bring module within maximum 1 meter 3 feet of the main controller e enable add remove mode on main controller e auto inclusion 30 minutes after connected to power supply or e press service button S for more than 2 second or e press push button I1 three times within 3s 3 times change switch state within 3 seconds NOTE When connecting temperature sensor to module that has already been included you have to exclude module first Connect the sensor and re include the module Module Exclusion Reset Removing from Z Wave network e Connect module to power supply e bring module within maximum 1 meter 3 feet of the main controller e enable add remove mode on main controller e press service button S for more than 6 second or e press push button I1 five times within 3s 5 times change switch state within 3 seconds in the first 60 seconds after the module is connected to the power supply By this function all parameters of the module are set to default values and own ID is deleted If service button S is pressed more than 2 and less than 6 second module is excluded but configuration parameters are not set to default values Association Association enables Flush 1D relay module to transfer commands inside Z Wave network directly without main contr
Download Pdf Manuals
Related Search
Related Contents
1 Sensor inductivo NBB8-18GM60-A2-V1-3G-3D Niles Audio VCS-2D-HP User's Manual Akai AMD75 home audio set Operating manual I P BG PL H RO 3Com 10014302 Network Router User Manual NanoHARD Extenders Installation and Operation Manual - KVM KitchenAid KUDH24SE User's Manual Copyright © All rights reserved.