Extenders Installation and Operation Manual - KVM
Contents
1. Note Rackmount modules are not available with S Video support NTI XTENDEX 600 Foot Extenders MATERIALS Materials Included with this kit NTI XTENDEX Local Unit NTI XTENDEX Remote Unit 2 120VAC or 240VAC at 50 or 60Hz 9VDC 1 0A AC Adapters only 1 ST C5KM 600 CD with a pdf file of this owner s manual Y Y Y Y Additional materials may need to be ordered depending upon the configuration gt CAT5 5e 6 unshielded twisted pair cable s terminated with RJ45 connectors wired straight thru pin 1 to pin 1 etc see pg 8 for proper EIA TIA 568 B wiring method Note Shielded CAT 5 5e or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission requirements Cable s needed if Local Unit will be located further than 15 from the CPU Model Cable s needed ST C5KVM 600 VKMEXT xx xx 3 6 10 15 25 35 50 75 100 feet ST C5KVMRS 600 VKMEXT xx and DINT xx ST C5KVMA 600 VKMEXT xx and SA xx MF ST C5V 600 VEXT xx ST C5VRS 600 VEXT xx and DINT xx ST C5VA 600 VEXT xx and SA xx MF ST C5SV 600 SVEXT xx ST C5SVA 600 SVEXT xx and SA xx MF ST C5KM 600 VVKINT xx or VVKEXT xx Cables Lengths Available Cable xx Length in feet VKMEXT xx 3 6 10 15 25 35 50 75 100 VEXT xx 3 6 10 15 25 35 50 75 100 DINT xx 6 10 15 SA xx MF 6 12 25 50 SVEXT xx 1 3 6 10 15 25 35 50 75 100 VVKINT xx 3 6 10 15 25 VVKEXT xx 35 50 75 100
2. A a NETWORK 1275 Danner Tel 330 562 7070 wm m m TECHNOLOGIES Aurora 44202 Fax 330 562 1999 E S INCORPORATED www networktechinc com 600 FOOT EXTENDERS Installation and Operation Manual ST C5KVM 600 PS 2 KVM Extender ST C5KVM 600M VMCTINT 3 MM PS 2 KVM Extender sold separately C Man014 Rev 6 26 09 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the U S and other countries COPYRIGHT Copyright 2003 2009 by Network Technologies Inc All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users Note Shielded CAT 5 5e or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission and immunity requirements Note CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground outdoors or between buildings WARNING Outdoor or underground runs of CAT5 cab
3. iem Rete RU a hd Ge hee diee eei Re t de tee PO Bi ied eee 6 Preparation for Installation cites iere ii td ehe Re eee no dade dtd e ridet ri ee eR ada 6 Installation ts iR etre pta ed e eh oH attt dete EHE ed vo vereda 7 Installing The Local Unit models with VGA video connectors eene 7 Installing The Local Unit models with S Video connectors eene nemen 9 Installing the Local Unit models with only KM connectors sssseee emm emm eene 10 Connect The CATS Cable ee eerte e dp NI e eee pM en ea aie ee eae pes 11 Installing The Remote Unit models with VGA video meme 11 Installing The Remote Unit models with S Video connectors sssssseee emm emen 13 Installing The Remote Unit models with only KM connectors sssseeeem em emm emnes 14 Connect the CATS cable nope ea A ae ee PERI Rr i ues 14 Plug in and Boot lp recedere rt det tae RR Oe er er ODE DL ed e a Tt bus 15 Rackmount Modules Optional jc 0 ettet erede Ue tede t EL ed reed epi ae Mae eerta de rated 16 Mount the ST C5RCK 12 Rackmount Extender Module Tray sss eene 16 Gonnectthie CPU s ima depo ttr dc EO d eH Ea red ode E aes 18 Gornnect the DEVICES ur o edere d P der d HE e odii etes co HR be o eb ter 19 Connectithie CATS Cable icin ihnen eerte d de tid er eden 20 Plugzinand Boot Up t e eet e e re LA Gees Pepe
4. Figure 21 Connect AC adapters 21 Figure 22 Buttons for video quality 22 Figure 23 View looking into RJ45 female sssssesseseseeeeeneeneneeneen 24 ii NTI XTENDEX 600 Foot Extenders INTRODUCTION The XTENDEX Series CAT5 Extender XTENDEX is designed to enable one CPU to be controlled by two users one local and one remote The remote user can be located as much as 600 feet away from a PS 2 CPU via Category 5 unshielded twisted pair cable The local user will be located near the CPU Option Rackmount Modules The XTENDEX Series CAT5 Extenders can be ordered as rackmount modules Remote and or Local Units add M to the model number i e ST C5KVM 600M When ordering rackmount modules also order the ST C5RCK 12 Rackmount Extender Module Tray see page 16 The XTENDEX Series Extender is extremely simple to install and has been thoroughly tested to insure reliable performance Through the use of Category 5 cable it is possible to economically increase the flexibility of a computer system Here are some of the features and ways this can benefit any workplace Allows the placement of computer peripherals monitor keyboard and mouse in a location where only these parts are needed without having the CPU there too
5. For Rackmount Modules the following materials are required not supplied Model Cables needed ST C5KVM 600M ST C5KVMRS 600M VMCTINT xx MM and VMCTINT xx VMRSTINT xx MM and VMRSTINT xx ST C5KVMA 600M VMATINT xx MM and VMATINT xx ST C5V 600M VTINT xx MM and VTINT xx ST C5VRS 600M VRSTINT xx MM and VRSTINT xx ST C5VA 600M VATINT xx MM and VATINT xx Legend xx 3 6 10 15 or 25 foot length MM cables have male connectors on both ends except for the DB9 and are only used with Local Units Note If two users will be connected one local and one remote two of the cables without the MM i e VMCTINT xx will be needed Contact your nearest NTI distributor or NTI directly for all of your KVM needs at 800 RGB TECH 800 742 8324 in US amp Canada or 330 562 7070 Worldwide or at our website at http www networktechinc com and we will be happy to be of assistance NTI XTENDEX 600 Foot Extenders FEATURES AND FUNCTIONS Front View Rear View ST C5KVMRS 600 Local Unit 15 3 4a Front View Rear View ST C5KVMA 600 Local Unit 8b 11c 114 Front View Rear View ST C5SVA 600 Local Unit Front View Rear View ST C5KM 600 Local Unit NTI XTENDEX 600 Foot Extenders FEATURES AND FUNCTIONS Green LED traffic indicator illuminates when there is communication between the local and remote units 2 Yellow LED power indicator illuminat
6. N WARNING Never connect the XTENDEX to an Ethernet card Ethernet router hub or switch or other Ethernet RJ45 connector of an Ethernet device Damage to devices connected to the Ethernet may result Green Traffic LED Yellow Power LED CAT5 Cable to Remote Unit Figure 8 Connect CAT5 cable to Local Unit Installing The Remote Unit models with VGA video connectors 1 Position the Remote Unit such that the CAT5 cable the monitor cable device cables and the AC adapter power connector can each reach the Remote Unit without putting strain on the cables 2 Connect the monitor cable to the female 15HD video connector on the Remote Unit 3 Connect the device s to the Remote Unit see Figure 9 KVM models only a Connect the keyboard to the purple female 6 pin miniDIN connector on the Remote Unit b Connect the mouse to the green female 6 pin miniDIN connector on the Remote Unit 4 If the Remote Unit has RS232 support connect the remote user s RS232 cable from a touch screen monitor to the 9D male port on the Remote Unit 5 If the Remote Unit has audio support connect the cable from the remote speakers to the 3 5mm stereo audio jack on the Remote Unit See Figure 9 11 NTI XTENDEX 600 Foot Extenders ST C5KVMRS 600 Remote Unit Front and Rear View 9D Male RS232 Connector Front View of Remote Unit Rear View of Remote Unit 15HD Female Video Connector 6 pin miniDIN Femal
7. taking up valuable space Allows a PS 2 CPU to be accessed by both a local and remote user up to 600 feet away Compatible with XGA VGA and SVGA systems Provides crisp and clear resolution up to 1024 x 768 600 feet see page 21 for more details Compatible with all NTI switches and splitters enabling the joining of products to create a system that satisfies all networking needs Video quality adjustment for varying lengths of cable is automatic most models see below and page 20 providing optimum image quality Audio frequency response is 20Hz to 20Khz 1Db models with audio support only Digital transmission of audio signals reduces any loss in quality models with audio support only This manual covers each of the XTENDEX Series CAT5 600 Extender models offered Some features described in this manual are available in some models and not in others The chart below shows the features supported in each Model Video Keyboard Mouse Audio RS232 Video Quality Support Support Support Adjustment ST C5KVM 600 VGA Yes No No Automatic ST C5KVMA 600 VGA Yes Yes No Automatic ST C5KVMRS 600 VGA Yes No Yes Automatic ST C5V 600 VGA No No No Manual ST C5VA 600 VGA No Yes No Automatic ST C5VRS 600 VGA No No Yes Automatic ST C5SV 600 S Video No No No Manual ST C5SVA 600 S Video No Yes RCA No Automatic ST C5KVMRS 600 SCI VGA Yes No Yes Manual ST C5KM 600 NO Remote only No No Not Applicable
8. DSR General Interconnect Cable Remote and Local Unit Power Dimensions WxDxH In Local or Remote Dimensions WxDxH In Local or Remote CAT5 5e 6 Solid UTP EIA TIA 568 B wiring w male RJ45 connectors 120V or 240V at 50 or 60Hz 9VDC 1 0A via AC Adapters 2 3 1x3 4x1 Desktop models 1 4x6 8x3 5 Rackmount modules Distances and Resolutions for CAT5 CAT5e and CAT6 Cables Unshielded Twisted Pair UTP Resolutions UTP CABLE DISTANCE feet RESOLUTION CATS CAT5e 600 1024x768 at 60Hz CATS CAT5e 400 1280x1024 at 60Hz CATS CAT5e 300 1600x1200 at 60Hz CATS CAT5e 100 1920x1440 at 60Hz CAT6 300 1024x768 at 60Hz CAT6 200 1280x1024 at 60Hz CAT6 100 1920x1440 at 60Hz 23 NTI XTENDEX 600 Foot Extenders INTERCONNECTION CABLE WIRING METHOD The connection cable between the remote and local is terminated with RJ45 connectors and must be wired according to the EIA TIA 568 B industry standard Wiring is as per the table and drawing below Pin Wire Color Pair Function 1 White Orange 2 T 2 Orange 2 R 3 White Green 3 T 4 Blue 1 R 5 White Blue 1 T 6 Green 3 R 7 White Brown 4 T 8 Brown 4 R Figure 23 View looking into RJ45 female TROUBLESHOOTING Each and every piece of every product produced by Network Technologies Inc is 10096 tested to exacting specifications We make every effort to insure trouble free installation
9. EE ede e e 21 Video Quality 0 blu dest moto cote ett don ale reo d Up ea 22 TechnicalSpecifIcatlons 1 ep rr er IRE Pe eedem UAI Dese tena deste ete Sa gla cao eade totas 23 Interconnection Cable Wiring Method nennen nenne innen ener enne 24 Troubleshooting ior truth ed dede t de dre E o ei NI dod ofi 24 Indext s ied tdt tente tun ied 25 Watrahty InfOrmmationi PO t ten Pte tentus 25 TABLE OF FIGURES Figure 1 Connect the Local Unit with VGA video RS232 support to the 7 Figure 2 Connect the Local Unit with Audio support to the CPU ssssssssesssee eene 8 Figure 3 Connect the local user to the XTENDEX Local nennen enne nennen nennen nennen 8 Figure 4 Connect stereo speakers to XTENDEX Local Unit with audio support sssseseeene emm eene 9 Figure 5 Connect the S Video Local Unit to the s video audio 5 ene enemies 9 Figure 6 Connect S Video display and speakers to Local Unit with s video support sssee eem 10 Figure 7 Connect Local Unit with only keyboard and mouse support enne nnne nennen nennen 10 Figure 8 Connect CAT5 cable to Local Unit ccc ces
10. been made to them See Figure 14 Rear View of Remote Unit 9 VDC ADAPTER Green Traffic LED Barrel Yellow Power LED Power Connector 9VDC 1 0A OUTPUT Outside Inside barrel e barrel 2 1 mm x 5 5 mm Female Figure 14 Connect the AC adapter to the Remote Unit 3 Turn ON the CPU and Monitor They should each react as if they were directly connected to each other Note The green LED on each RJ45 connector will illuminate anytime data traffic is passing between the Local and Remote Units indicating proper CAT5 cable connection and communication See Figure 14 15 NTI XTENDEX 600 Foot Extenders Rackmount Modules optional If ST C5 600M Series XTENDEX rackmount modules Local and or Remote modules are being installed then an ST C5RCK 12 Rackmount Extender Module Tray must be used sold separately to mount the modules to a RACK The ST C5RCK 12 provides a convenient mounting method for up to 12 Local and or Remote XTENDEX modules Note Rackmount Local modules are compatible with rackmount Remote modules or desktop Remote units Mount the ST C5RCK 12 Rackmount Extender Module Tray 1 The ST C5RCK 12 Rackmount Extender Module Tray was designed to be directly mounted in a rack It includes a mounting flange to make attachment easy 2 Install 4 cage nuts supplied to the rack in locations that line up with the holes in the mounting flange on the tray Then secure the tray to the r
11. chart 23 ST C5RCK 12 16 technical specification 23 video quality adjustment 22 WARRANTY INFORMATION The warranty period on this product parts and labor is two 2 years from the date of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regarding repairs and or returns A return authorization number is required for all repairs returns Note CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground outdoors or between buildings WARNING Outdoor or underground runs of 5 cable could be dangerous and will void the warranty Manual 014 Rev 6 26 09
12. e Headphone out typically located on the CD ROM e To connect the ST C5SVA 600 to a CPU it may be necessary to use an RCA phono to 3 5mm stereo jack adapter e The audio output of the XTENDEX with audio support is compatible with self powered stereo speakers PREPARATION FOR INSTALLATION Locations should be chosen for the monitors mice and keyboards that also have space to connect the Remote and Local Units within the distance provided by the cables If extension cables are needed contact NTI for the cables required e 5 cables must be run to the locations where the Remote and Local Units will be connected Be careful to route the cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the video signal i e AC motors welding equipment etc All cables should be installed in such a way that they do not cause stress on their connections to the equipment Extended lengths of cable hanging from a connection may interfere with the quality of that connection Secure cables as needed to minimize this e Properly shut down and disconnect the power from the CPU and monitors to be separated If other equipment is involved whose connections are being interrupted be sure to refer to the instruction manuals for that equipment for proper disconnection and re connection procedures before proceeding Note CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any
13. s video port on the Local Unit c If the Local Unit has audio support connect the cable from the local speakers into the 3 5mm jack on the local unit ST CSVA 600 Local Unit Front View Rear View 3 5mm Stereo Audio Jack SVEXT xx MM S Video Display Speakers Local User s Display Figure 6 Connect S Video display and speakers to Local Unit with s video support Installing the Local Unit models with only KM connectors 1 Plug the cables of the Local Unit into the back of the CPU See Figure 7 a Connect the green 6 pin miniDIN cable end with the mouse symbol on it to the mouse port on the back of the CPU b Connect the purple 6 pin miniDIN cable end with the keyboard symbol on it to the keyboard port on the back of the CPU DEVICE CONNECTORS olo 6 miniDIN Female Connector 6 pin miniDIN GREEN MOUSE Male Connector PURPLE KEYBOARD PS 2 CPU ST C5KM 600 Local Unit Front View Figure 7 Connect Local Unit with only keyboard and mouse support 10 NTI XTENDEX 600 Foot Extenders Connect The CAT5 Cable Rear View of Local Unit Connect the CAT5 cable to the Cat 5 port on the Local Unit See Figure 8 When properly inserted the cable end should snap into place XJANILX Note If an RJ45 wall outlet is being used connect the other end of the extension cable to the RJ45 wall outlet
14. 1d Audio Plug white RCA plug for connecting to the left channel audio model ST C5SVA 600 only 12 Keyboard Connector purple female 6 miniDIN for connecting the remote user s keyboard 13 Mouse Connector green female 6 miniDIN for connecting the remote user s mouse 14a RS232 Connector 9D male for connecting the remote user s touchscreen monitor models with RS232 support only 14b Audio Jack 3 5mm stereo audio jack for connecting to remote speakers models with audio support only 15 9VDC 1 0A connection jack for the AC adapter 16a Video Connector 15HD female for connecting the remote user s monitor 16b S Video Connector 4 pin miniDIN female for connecting the remote user s S video display S Video models only 17 Buttons for manually adjusting video quality models ST C5V 600 ST C5SV 600 and ST C5KVMRS 600 SCI only Front View ST C5KVMA 600 Remote Unit ear View NTI XTENDEX 600 Foot Extenders Front View ST C5SVA 600 Remote Unit Rear View 13 12 Front View 1 Rear View ST C5KVMRS 600 SCI Remote Unit 3 15 Front View Rear View ST C5KM 600 Remote Unit XTENDEX Kvm ST C5KVM 600M REMOTE UNIT O XTENDEX kvm ST C5KVM 600M LOCAL UNIT www networktechinc col ST C5KVM 600M www net tworktechinc com ST C5KVM 600M ST C5KVM 600M ST C5KVM 600M Remote Module Local Module Front and Rear Views Front and Rear Views All XTENDEX
15. 600 foot extender modules have the same connections 18 USER 05 SCSI Il Female for connecting cable between module and the user devices 19 CPU 05 SCSI II Female for connecting cable between the module and the CPU NTI XTENDEX 600 Foot Extenders LIMITATIONS e Hot plugging of devices is supported provided devices were originally connected at power up e order for two users to share a PS 2 CPU the user in control must pause for at least 3 seconds before another user can take control After the 3 second pause either user can take control of the CPU For models with RS232 support e RS232 ports on the Local and Remote Units will support serial devices other than touchscreen monitors as follows 2 simple devices i e mice connected to each unit or 1 complex device i e serial modem RS232 command port on an NTI switch connected to either the Remote or Local Unit e In order for two users to share a PS 2 CPU the user in control must pause for at least 3 seconds before another user can take control After the 3 second pause either user can take control of the CPU e RS232 port supports all baud rates up to 56K bits per second and the attached CPU must be configured accordingly For models with audio support e The audio input of the XTENDEX with audio support is compatible with the following standard CPU audio outputs Line out typically lime green in color Speaker out typically orange in color
16. XTENDEX Series products should not be run underground outdoors or between buildings WARNING Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty NTI XTENDEX 600 Foot Extenders INSTALLATION Installing The Local Unit models with VGA video connectors 1 Plug the cables of the Local Unit into the back of the CPU See Figure 1 a Connect the blue 15HD cable end to the VGA port on the back of the CPU b Connect the purple 6 pin miniDIN cable end with the keyboard symbol on it to the keyboard port on the back of the CPU KVM models only Keyboard c Connect the green 6 pin miniDIN cable end with the mouse symbol on it to the mouse port on the back of the CPU KVM models only Mouse DEVICE LIGHT GRAY RS232 CONNECTORS i 0000 9D Female Connector 6 pin miniDIN 6 pin miniDIN F JE Male Connector SERIAL CONNECTOR 9D Male RS232 Connector BLUE VIDEO PS 2 CPU eS ai dM VIDEO MEE ST C5KVMRS 600 Local Unit EY o Front View 00000 _15HD Male 15HD Female Video Connector Video Connector Figure 1 Connect the Local Unit with VGA video and RS232 support to the CPU d Ifthe Local Unit has RS232 support connect the light gray 9D cable end to the RS232 port on the back of the CPU e Ifthe Local Unit has Audio support connect the black 3 5mm stereo plug into the lin
17. ack using four 10 32 x 3 4 screws supplied Be sure to tighten all mounting screws securely 7 Q S Q 10 32 x 3 4 gt S Cage Nuts Rack Screws Tse supplied supplied Ww 3 Figure 15 Mount ST C5RCK 12 Extender Module Tray in a rack 3 Slide each module into the tray and line up the holes in the mounting plate on the module with corresponding holes in the tray Secure the module s using the two screws provided Blank plates and screws are provided to cover empty module spaces Frontview of ST C5RCK 12 with XTENDEX Extender Modules s 4 e 4 72 g x N LESTE 7 Fd Fi X X x N N EN N N c LJ EA EX EYE Q Q c 4 Secure XTENDEX module s to the ST C5RCK 12 using the screws provided Figure 16 Secure each module to the tray 4 Secure the power supply for each module to the power supply cable management shelf at the rear of the tray using the bracket and screw supplied 16 NTI XTENDEX 600 Foot Extenders Rearview of ST C5RCK 12 with XTENDEX Extender Modules Plug power connector into Extender module ce Power supply mounting bracket ec Secure each power supply to the tray supplied with each module using the bracket and screw provided Figure 17 Secure each power supply to the tray 17 NTI XTENDEX 600 Foot Extenders Connect the CPU Connect a cable between the Local Unit and the CPU Use the appropriate cable for the applicatio
18. and operation of our products If problems are experienced while installing this product please look over the troubleshooting chart below to see if perhaps we can answer any questions that arise If the answer is not found in the chart please check the FAQs Frequently Asked Questions at our website at http www networktechinc com or contact us directly for help at 1 800 742 8324 800 RGB TECH in US amp Canada or 1 330 562 7070 worldwide We will be happy to assist any way we can Problem Cause Remote or Local Unit e Power supply is not connected or sure outlet is live and AC adapter is plugged in yellow power LED does plugged in one for the Remote and one for the Local not illuminate Make sure 9VDC jack is fully connected Local power LED does keyboard connector is not e Check keyboard connection not illuminate when the properly plugged in CPU is powered No Video on monitor One or more video cables is loose Check all video cable connections or disconnected No power to Remote or Local Make sure yellow LEDs are illuminated for local and Units remote If not see solutions for first two problems above e With all the cables properly connected reboot the CPU e Video Cable was not attached e Check cable connections Make sure they are snapped when CPU was booted in properly and completely and reboot e CAT5cable is not connected Video Picture is not sharp All Video Cables are not fi
19. e Connector VGA Multi Scan Monitor PS 2 KEYBOARD PS 2 MOUSE Remote User s Keyboard Monitor and Mouse Figure 9 Connect the Extended Components to the Remote Unit ST C5KVMA 600 Remote Unit Front View XTENDEX 3 5mm Stereo Audio Jack e Speakers Figure 10 Connect speakers to the Remote Unit 12 NTI XTENDEX 600 Foot Extenders Installing The Remote Unit models with S Video connectors 1 Position the Remote Unit such that the CAT5 cable the s video cable speaker cable and the AC adapter power connector can each reach the Remote Unit without putting strain on the cables 2 Connect one 4 pin miniDIN end of another SVEXT xx MM cable to the Remote Unit 3 Connect the other 4 pin miniDIN end of the SVEXT xx MM cable to the s video port on the display 4 Ifthe Remote Unit has audio support connect the speakers to the 3 5mm jack on the Remote Unit see Figure 11 ST C5SVA 600 Remote Unit Front View Rear View Audio Jack S Video Display Remote User s Display Figure 11 Connect components to an S Video Remote Unit 13 NTI XTENDEX 600 Foot Extenders Installing The Remote Unit models with only KM connectors 1 Position the Remote Unit such that the CAT5 cable the keyboard cable mouse cable and power supply cable can each reach the Remote Unit without putting strain on the cables 2 Connect the keyboard to the purple female 6 pin miniDIN c
20. e out spkr or headphones jack on the back of the CPU See Figure 2 Notes If all 3 jacks are available use the jack marked line out The line out jack is typically lime green and may be marked with this symbol J The spkr jack is typically orange and may be marked with this symbol mq The headphones jack may be marked with this symbol NTI XTENDEX 600 Foot Extenders AUDIO CONNECTOR ONE WILL BE MARKED line out spkr headphones OR WITH THIS SYMBOL gt BLACK AUDIO ST C5KVMA 600 Local Unit Front View PS 2 CPU 3 5mm Stereo Plug Figure 2 Connect the Local Unit with Audio support to the CPU 2 Make connections for a local user see Figure 3 Connect the cable from the local user s VGA monitor to the female 15HD port on the Local Unit a b Connect the local user s keyboard to the purple 6 pin miniDIN female port on the Local Unit c Connect the local user s mouse to the green 6 pin miniDIN female port on the Local Unit ST C5KVMRS 600 Local Unit Front and Rear View 9D Male RS232 Connector Front View of Local Unit 15HD Female Video Connector 6 pin miniDIN Female Connector Multi Scan Touch screen Monitor PS 2 KEYBOARD PS 2 MOUSE Local User s Keyboard Monitor and Mouse Figure 3 Connect the local user to the XTENDEX Local Unit NTI XTENDEX 600 Foot Extenders d If the Local Unit has RS232 support connect the local user
21. ections for the ST C5KVMA R 600M remote unit using a VMATINT xx cable xx 3 6 10 15 or 25 foot length Use the appropriate cable for the application see chart below Make sure all connections are firmly seated 0 05 SCSI II series 45HD Female VGA 1 Multi Scan VMATINT 3 6 10 15 25 V deo Connector Monitor Connect to ST C5KVMA R 600M Local Unit or Remote Unit at USER 6mD Female Keyboard Connector Purple c annu moon nano uuu x en ooo was onpi CN 2 caononaQdanagnoud naa ac gOgouonuuocets ono Be epa eal 6mD Female Mouse Connector Green REAR VIEW ST C5KVMA R 600M www networktechinc com Remote Unit ST C5KVMA 600M Figure 19 Connect cable between user and module Cables for connecting 600M modules to user devices Features Supported Cable To Use Video Keyboard Mouse Audio RS232 VMCTINT xx Y Y N N VMATINT xx Y Y Y N VMRSTINT xx Y Y N Y VTINT xx Y N N N VATINT xx Y N Y N VRSTINT xx Y N N Y xx 3 6 10 15 or 25 foot length 19 NTI XTENDEX 600 Foot Extenders Connect the CAT5 cable Connect the CAT5 cable to the CAT5 port on the front of the Local Unit see Figure 20 When properly inserted the cable end should snap into place Connect the other end of the cable to the CAT5 port on the Remote Unit or other Ethernet RJ45 connector of an Ethern
22. es when power has been supplied to the unit 3 Cat 5 RJ45 female for connecting the CAT 5 cable 4a Video Connector 15HD female for connecting the local user s VGA monitor 4b S Video Connector 4 pin miniDIN female for connecting the local user s S video display S Video models only 5a RS232 Connector 9D male for connecting the local user s touchscreen monitor models with RS232 support only 5b Audio Jack 3 5mm stereo audio jack for connecting to local speakers models with audio support only 6 Mouse Connector green female 6 miniDIN for connecting the local user s mouse 7 Keyboard Connector purple female 6 miniDIN for connecting the local user s keyboard 8a Video Connector blue 15HD male for connecting to the video port on the CPU or KVM switch 8b S Video Connector black 4 pin miniDIN male for connecting to the s video port on the video source S Video models only 9 Mouse Connector green male 6 miniDIN for connecting to the mouse port on the CPU or KVM switch 10 Keyboard Connector purple male 6 miniDIN for connecting to the keyboard port on the CPU or KVM switch 11a RS232 Connector light gray 9D female for connecting to the RS232 port on the CPU or KVM switch models with RS232 support only 11b Audio Plug 3 5mm stereo audio plug for connecting to CPU audio line out models with audio support only 11c Audio Plug red RCA plug for connecting to the right channel audio model ST C5SVA 600 only 1
23. et device Damage to devices connected to the Ethernet may WARNING Never connect the XTENDEX to an Ethernet card Ethernet router hub or switch result ST C5KVMA R 600 Remote Unit Front View XAGNALX Yellow Power LED Green Traffic LED ST C5KVMA R 600M Remote Unit Front View SSS 2 XTENDEX kvm ST C5KVM 600M LOCAL UNIT CAT5 Cable up to 300 feet Connect Local unit to either rackmount Remote Unit module ST C5KVMA R 600M or desktop Remote Unit ST C5KVMA R 600 XTENDEX kvm ST C5KVM 600M REMOTE UNIT Figure 20 Connect the CAT5 cable between the Local and Remote Units 20 NTI XTENDEX 600 Foot Extenders Plug in and Boot Up 1 Plug the power cord s from the monitor s into power outlet s 2 Connect the AC adapter power connectors to the 9VDC ports on the Remote and Local Units AC adapter shown in Figure 21 3 Plug the AC adapters into power outlets The Power LED yellow on the CAT5 connector of each unit should illuminate indicating that a proper power connection has been made 4 Turn ON the CPU and monitor s The CPU and monitor s should each react as if they were directly connected to each other The green Traffic LEDs on the Remote and Local Units see Figure 20 should blink indicating there is proper communication between them Note A loss of signal blank screen may be experienced for an instant during the auto
24. eversed Cat5 cable is too long Check cable connections Cat 5 cable can be no more than 600 feet in length IBM Scroll Point mouse is not recognized by CPU Only one IBM Scroll Point mouse is connected at either the Local or Remote unit In order for an IBM Scroll Point mouse to be recognized an IBM Scroll Point mouse must be connected at both the Local and Remote extender units Otherwise it will be recognized and work only as a Microsoft Intellimouse Image is not displayed properly lacks definition Models with RS232 Support Signal is being skewed by the CAT5 cable and not being received correctly by the monitor Check the user s manual for the monitor projector or display equipment for an automatic adjustment or auto configure This is most common to LCD type monitors No RS232 communication e One or more RS232 cables is loose or disconnected Check all RS232 cable connections Models with Audio Support No audio Audio cable is not properly plugged in e Speakers are not plugged in e 5 cable is not properly connected Check all cable connections Verify speakers are connected and powered Check 5 cable connections INDEX cables needed 2 cables to CPU 18 cables to user 19 cat5 cable pinout 24 installation desktop 7 installation rackmount 16 limitations 6 mount to a rack 16 preparation to install 6 Rackmount modules 16 resolution
25. le could be dangerous and will void the warranty CE Statement We Network Technologies Inc declare under our sole responsibility that the ST C5KVM 600 M STCSKVMRS 600 M STC5VMA 600 M ST C5V 600 M STC5VRS 600 M ST C5VA 600 M ST C5SV 600 and ST C5SVA 600 is in conformity with European Standard EN55022 Federal Communications Commission Radio Frequency Interference Statement This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that might cause undesired operation This device complies with Part 15 of the FCC rules This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment Warning This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications TABLE OF CONTENTS nwt Serie tee cine eRe ee te eet Em 1 Materials 4 eee ad 2 Features and FUNCUONS Ase teen ade dete el det eee idea ede eee nel de le eae 4 Limitations A E
26. matic video quality adjustment process after powering up This may also occur if the XTENDEX senses a loss of or weak signal connection in the CATS5 cable ST C5KVMA 600M Local Unit Rearview SSE ekk www networktechinc com ST C5KVMA 600M REAR VIEW ST C5KVMA L 600M Local Unit Figure 21 Connect AC adapters 21 NTI XTENDEX 600 Foot Extenders VIDEO QUALITY Automatic Video Quality Adjustment see chart on page 1 Video quality adjustment is done automatically to assure the image is as clear as possible Note When the cable is longer than 300 feet some colored lines can be seen at the black to white transitions This is a normal behavior and is caused by the different twisting rates of each pair of wires the CAT5 cable Manual Video Quality Adjustment see chart on page 1 It is possible that on initial startup the image on the monitor will not be as crisp as the image normally is This is due to the frequency characteristics of the CAT5 cable It be necessary to press the or buttons see Figure 22 until the image is crisp and clear Press the button if the image is not crisp and clear enough Press the button if the image has been over corrected such that horizontal lines appear to trail or shadow at the edge of an open window A momentary press of either button will make a minor change in the image If either button is pressed and held the changes made will be gradual and continu
27. n see chart below Figure 18 shows the proper connections for the ST C5KVMA L 600M using VMATINT xx MM cable xx 3 6 10 15 or 25 foot length AUDIO CONNECTOR O ONE WILL BE MARKED line line out out speaker headphones OR WITH THIS SYMBOL gt Make sure all connections are firmly seated 6mD Male Mouse Connector Green D 6mD Male Keyboard Connector Purple o PS 2 CPU 3 5mm Stereo Plug VMATINT 3 6 10 15 25 MM 0 05 SCSI Il series Connect to ST C5KVMA L 600M Local Unit at CPU 0000 00000 00000 15HD male Video Connector REAR VIEW gt ST C5KVMA L 600M Local Unit f LN 9 www networktechinc com ST C5KVMA 600M Figure 18 Connect cable between CPU and module Cables for connecting 600M modules to a CPU Cable To Use VMCTINT xx MM Features Supported Video Keyboard Mouse Audio RS232 VMATINT xx MM VMRSTINT xx MM VTINT xx MM VATINT xx MM VRSTINT xx MM lt lt lt lt lt lt gt gt gt lt lt lt 2 lt 1212 lt 2 xx 3 6 10 15 or 25 foot length 18 lt lt 7 NTI XTENDEX 600 Foot Extenders Connect the Devices Connect a cable to the monitor keyboard mouse speakers if supported and touch screen RS232 cable if supported and then to the Local or Remote Unit at the connector marked USER Figure 19 shows the proper conn
28. onnector on the Remote Unit 3 Connect the mouse to the green female 6 pin miniDIN connector on the Remote Unit ST C5KM 600 Remote Unit Front View 6 pin miniDIN Female Connector PS 2 MOUSE PS 2 KEYBOARD Remote User s Keyboard and Mouse Figure 12 Connect keyboard and mouse to Remote Unit Connect the CAT5 cable Make sure the CAT5 cable has been installed in accordance with the Preparation for Installation instructions on page Connect the CAT5 cable to the Cat 5 port on the Remote Unit See Figure 13 When properly inserted the CAT5 cable end should snap into place Rear View of Remote Unit Note If an RJ45 wall outlet is being used connect the other end of the extension cable to the RJ45 wall X ou t le t WARNING Never connect the XTENDEX to an Ethernet card Ethernet router hub or switch or other Ethernet RJ45 connector of an Ethernet device Damage to devices connected to the Ethernet may result CATS5 Cable to Local Unit Figure 13 Connect the CAT5 cable to the Remote Unit 14 NTI XTENDEX 600 Foot Extenders Plug in and Boot Up 1 Plug the power cord from the monitor into the power outlet 2 Connect each AC adapter power connector to the 9VDC ports on the Remote and Local Units Plug each AC adapter into a power outlet The yellow LED on the RJ45 connector of both the Remote and Local Units should illuminate indicating that a proper power connection has
29. ous Ultimately the image quality should improve to a satisfactory level Once the adjustment is made it should not be necessary to change it again as the new settings are stored in memory and become the default settings with each startup Note When the cable is longer than 300 feet some colored lines can be seen at the black to white transitions This is a normal behavior and is caused by the different twisting rates of each pair of wires the CAT5 cable Side view of ST C5V 600 Remote Unit XTENDEX v O G Press using pen or other pointed object to improve Front View screen image ST C5V 600M ST C5V 600M Remote Unit Figure 22 Buttons for video quality adjustment If the image still lacks definition configuration adjustments may need to be made to the attached video display equipment This is a problem most often seen in LCD displays Check the manual for the equipment having the poor display and look for an auto adjust or auto configure feature Once this is done you may need to repeat the Video Quality Adjustment procedure described above to achieve the best image 22 NTI XTENDEX 600 Foot Extenders TECHNICAL SPECIFICATIONS Models with VGA Video Video Compatibility SVGA XGA VGA Video Coupling DC Video Connectors HD15 male to CPU HD15 female to monitor Input Output Impedance 75 Ohms Input Horizontal Frequency Range 15kHz to 130 Hz Input Vertical F
30. requency Range 30 Hz to 150 Hz Sync Types Supported Separate and composite TTL Level and sync on green Video Maximum Levels 1 45Vp p Models with S Video Video Compatibility All s video displays and sources Video Coupling DC Video Connectors 4 pin miniDIN male to video source 4 pin miniDIN female to display Video Maximum Levels 1 45Vp p Input Output Impedance 75 Ohms Models with Keyboard Mouse support Keyboard Mouse Connectors Female 6 pin miniDIN to Keyboard and Mouse Male 6 pin miniDIN to CPU device ports Mouse and Keyboard Compatibility All PS 2 mice and keyboards Keyboard and Mouse Current Rating 500mA maximum Models with Audio Support Audio Connectors 3 5mm stereo jack to speakers 3 5mm stereo plug to CPU VGA Video Models RCA phono plug to audio source S Video Models Signal Type Line Level stereo unbalanced Audio Frequency Response 20Hz to 20Khz 1dB Signal to noise ratio 76 dBA Total Harmonic Distortion and Noise 0 017 Stereo Crosstalk 70 dB Audio Maximum I O Levels 3 1Vp p Output Impedance Max 2K Ohms unbalanced THD N Models with RS232 Support 0 017 F 20 20KHz RL 2K Ohm Vout 1 Vrms RS232 Connectors 9D male to device 9D female to CPU RS232 Baud Rate 56K bps maximum no adjustment for baud rate is needed RS232 Compatibility RXD TXD RTS DTR CTS
31. rmly e Check all connections Make sure all cables are fully or is smeared seated seated e CAT5 cable is too long e Verify length is within specified limits 600 CAT5 cable is not properly e Check cable connections Make sure they are snapped connected in properly and completely Video not adjusted e Check cable connections and power cycle If model has manual quality adjustment buttons see page 22 for adjustment instruction NTI XTENDEX 600 Foot Extenders Problem The picture on the monitor is black and white rather than color Cause The video cable was not attached to the CPU when it was booted With the cables all properly connected reboot the CPU A constant vertical wobble appears down the screen CAT5 cable is too close to a strong power source Reroute CAT5 cable if possible Monitor sometimes loses sync causing it to go blank for a second or two Electrical power system is very noisy particularly the ground e CAT5 cable is not properly connected Make sure the interconnection cable is not near any power lines Check cable connections Make sure they are snapped in properly and completely Wrong or missing characters from those typed The keyboard may be in the wrong mode Disconnect keyboard at Remote Unit end and reconnect Reboot the system CPU doesn t detect the keyboard and the mouse e Keyboard cable or mouse cable are loose or r
32. s RS232 cable from a touch screen monitor to the 9D male port on the Local Unit e Ifthe Local Unit has audio support connect the cable from the local speakers to the 3 5mm stereo audio jack on the Local Unit See Figure 4 ST C5KVMA 600 Local Unit Front View XTENDEX SFO wy Speakers Figure 4 Connect stereo speakers to XTENDEX Local Unit with audio support Installing The Local Unit models with S Video connectors 1 Plug the cables of the Local Unit into the back of the s video source See Figure 5 a Connect the 4 pin miniDIN male cable end to the s video port on the video source b Ifthe Local Unit has audio support connect the red RCA plug to the right speaker jack on the audio source and connect the white RCA plug to the left speaker jack on the audio source Note Refer to the owner s manual of the s video audio source to determine how the left and right audio channels are labeled 4 pin miniDIN Male S Video Connector XTENDEX 20 White RCA Plug DVD Player t Left Channel Red RCA Plug ST C5SVA 600 Local Unit Right Channel Front View Figure 5 Connect the S Video Local Unit to the s video audio source NTI XTENDEX 600 Foot Extenders 2 Make connections for a Local User see Figure 6 a Connect one end of an SVEXT xx MM cable to the s video port on the display b Connect the other end of the same SVEXT xx MM cable to the
33. seceeeesceeeeenseceeeenseeeeneceeeeesansesessoesessuneesdenuetesebecesneceeeseasteesecedsesssneeteenenaeees 11 Figure 9 Connect the Extended Components to the Remote Unit eee enne nnne 12 Figure 10 Connect speakers to the Remote Unit ssssssssssesseeeeeeenneen nennen nennen 12 Figure 11 Connect components to an S Video Remote 13 Figure 12 Connect keyboard and mouse to Remote Unit sssssssssesseeene enn enne nnnm nemen ennemis 14 Figure 13 Connect the CAT5 cable to the Remote Unit nennen eere 14 Figure 14 Connect the AC adapter to the Remote 15 Figure 15 Mount ST C5RCK 12 Extender Module Tray in a rack sssssssseeeeeeneeenen nennen nnne nnne emen enne 16 Figure 16 Secure each module to the 16 Figure 17 Secure each power supply to the tray ciiise daia iaia aiai riae ii iaa iria a 17 Figure 18 Connect cable between CPU and 18 Figure 19 Connect cable between user and module 19 Figure 20 Connect the CAT5 cable between the Local and Remote Units nennen 20