Home
IRDA-WELDER User Manual
Contents
1. 10 IRDA Workstation T862 User Manual 3 Soldering operation VClean up the welding plate with a brush lt TA cz t a at NR a 0 so N 12 te Ix 5 oy y Me t A tL m r s gt s amp ne 2 A gt 77 wg Qe a 2 4 an tug P B 2 Put the tin ball and spread soldering flux not too thick only a thin layer of it on the soldering plate 8 Put the chip in the accurate place after the solvent volatilizes out of soldering flux heat the tin ball until it melts and solder the chip 11 IRDA Workstation T862 User Manual a i a j Ma i i 4 Using the lead free soldering iron Switch on the power set the temperature that you need turn on the switches Caution 1 Do not cut the power off right after the work finished You need to wait until the fan cools down the lamp body 2 Keep the lamp body clean and the ventilation opening free of any obstructions 3 The guide rod and the focusing support should be spread with lubricant regularly 4 Pull out the power plug if you don t use it for a long term 5 Be careful of operating under high temperature conditions 12 IRDA Workstation T862 User Manual Warranty statement Reminder These machines are very heavy between 8 to 15 kilograms and are not designed to be shipped on airplanes but in containers that do not move We are not the shipping company th
2. The previous setting value demonstrated on the keyboard d splay monitor after you turn on the machine 3 Put PCB on the corresponding notch in PCB support and adjust the pinch nuts of locating ring and focusing support then adjust the height of infrared lamp body the ideal height between lamp and the unsoldering article is 20 30mm 4 Select the suitable heating temperature Select the suitable heating temperature of infrared lamp between 100 350 C according to the chip size that need to be unsoldered When you unsolder chips which are about 15x15mm you adjust the infrared lamp s temperature to 240 300 C When unsoldering chips which are about 30x30mm you adjust the infrared lamps temperature at 300 350 The infrared ray lights directly infrared ray is the strongest when the temperature is up to 350 you need pay attention to the timing and prevent from burning out the chip 5 Adjust the focus The minimum focal diameter of infrared lamp body is 15mm the maximum is above 30mm adjust them according to different chips Usually the ideal height between lamp and the chip is 20 30mm Adjust the focusing knob by the size of the chip Ideally the bright spot IRDA Workstation T862 User Manual should cover the whole chip 6 Turn on the two switches on the front panel for the pre heating plate and the infrared lamp 2 Unsoldering operation Adjust temperature make the center of the infrared lamp aim at the unsoldered chip
3. IRDA SMD amp BGA Rework Station T862 User Manual IRDA Workstation T862 User Manual CONTENT De INCALUTEOS ee E N OAE A E E 2 2 lechnical Parameteissu e rear 2 S List OF content a Baar e aS 2 4 Description of the main parts ccccccccsscccccccccccccsccccccsscece 3 CT Man DOoQy ses 3 2 FTONE ANC ee eisen 4 3 Back Dane le ua air 4 4 FOCUSING SUPPOTL une 5 Ss 1nStalaon s einer 6 CL install tne suide 700 ee a a 4 2 Install the locana TInS u neu 5 5 Complete Assembly aa 5 4 Connecting wire of the lamp body ss0000000nnnnnnensonnenns 7 6 Operating instructions nes ee 7 1 SEAR GING seen 7 2 Unsoldering Operation 8 5 Solder 2 operan Oheen a 8 4 Usine the soldering Von a 9 7 CAUTION near 9 a VV ALL aM nennen en 10 IRDA Workstation T862 User Manual Features Use of infrared welding technology which is developed independently Use of an infrared heat lamp Heat is easy to pierce and distribute evenly which overcome disadvantage burn out elements of traditional welding machines Easy operation You just need one day training and you can operate it skillfully No need for unsolder tools RDA Welder T 862 can unsolder all the elements between 15 and 25 mm This machine has 350W hot melt system Its preheating area is 80x 120mm Infrared heating without heated air flowing No impact on circumjacent small elements It is suitable for all of the elements es
4. e airplane crew the customs agent or the carrier in your country and therefore take no responsibility for damage caused in transit Corollary When our machines leave QC they are tested 100 new and in perfect condition These machines consist of modules Should you receive a faulty or damaged module we will be happy to replace it However we will not replace the complete machine this is not covered by our warranty PUHUI is responsible to give proper guidance of the use and installation of the machine if you don t follow these it will void the warranty 13
5. pecially Micro BGA elements IRDA Workstation T862 User Manual 2 Technical parameter AC220V S0Hz Working Voltage AC110V 60Hz Infra red lamp body temperature adjustable 100 C 350 C Preheating dish temperature adjustable 60 C 200 C Components BEE SEE IRDA Workstation T862 User Manual T 862 illustrated explaining 1 The whole machine Protection Cover of the fan The end covering Lamp body Filter and Cover a 936 soldering iron support I oy Focus holder 936 soldering iron Focusing knob Holder for PCB board M Welder base working bench Front panel IRDA Workstation T862 User Manual 2 Front Panel Infrared lamp Peak temperature 936 temperature display Preheater plate temperature display Infrared Lamp Switch soldering Iron Switch Preheater plate Switch IEDA I e BMBABGA Rework Hation SCH NE DIT see electrons fools com Temperature level regulation Button Back Panel Connecter for Power Input Connecter for 936 infrared Lamp soldering ron IFA LIGHT GUN IRDA Workstation T862 User Manual 3 Focusing support IR Lamp Cooling Fan Guide rod Focusing knob P Focusing support Pinch nut of focusing support Pinch nut of locating ring Locating ring IRDA Workstation T862 User Manual Installat on 1 Install the guide rod Loosen the pinch nut of focusing suppor
6. t put the guide rod in according to the direction of arrow icon pointing Note The Infrared Head Body Mounting and Focus Assembly will be installed in the T 862 chassis later The direction of guide rod N 2 Inventory all Items confirm no parts are missing If parts are missing call 0086 538 6138575 3 Put the locating ring in Loosen the pinch nut of locating ring put the locating ring in according to the arrow icon pointing and fasten the nut to the appropriate height Locating ring The direction of the locating ring 4 Machine Assembled O Loosen the pinch nut of focusing support Http www tech168 cn 7 IRDA Workstation T862 User Manual O Pick up focusing support make the guide rod aim at the corresponding nut on the base then rotate the guide rod O Fasten the focusing support by rotating pinch nut of it O Rip off the protective film of the filter Rotation Direction 5 Connecting the wire of the lamp body Get the adapter of connecting wire plug in the socket of infrared lamp connecting wire Rotate set screw clockwise 6 Attach IR Eye protective filter with the supplied screw and nut T 862 Operation Circuit Board Support Welder base work bench IRDA Workstation T862 User Manual 1 Starting 1 Inspect the infrared lamp body temperature sensor and power line and see if they are n good connection 2 Turn on the power switch then use self checking first
Download Pdf Manuals
Related Search
Related Contents
Highway Addressable Remote Transducer ES Manual de instrucciones Tricity Bendix AW 1054 W User's Manual jeep grand cherokee 2” suspension lift kit User Manual @CIG2008 - Oracle Documentation 20ーー年 8月 4日改訂 Copyright © All rights reserved.
Failed to retrieve file