Home
Triton Plus Ported RS-422 Data Routers Product Overview
Contents
1. Triton Plus Ported RS 422 Data User Manual Specifications Note Specifications All specifications are subject to change without notice Table 13 Triton Plus Ported RS 422 Data Router Specifications Parameter Value Router Signal type RS 422 data Data rate 115200 kbps Connector DB9 pin female according to SMPTE 207M AC power External power supplies 100 260VAC Maximum power consumption lt 20W Mechanical Dimensions 483 x 45 mm 19 in 2RU Safety Emissions standards Compliant with CE EN55103 1 and 2 FCC part 15 Power Supply TPS PWR 40 40W power supply unit Triton Plus router series AC supply voltage range 100 240VAC 50 60Hz max 1 6A AC mains connector IEC 320 DC output 15V max 2 2A 15V max 1 35A Maximum 43W DC connector DBS female Status monitoring Via LED in front of router CP Control Standard Features Serial port RS 232 for protocol conversion to Triton Plus compact control protocol or to 3rd party protocols Connector DB9 female NCB ports 1 in 1 out Connectors 2 RJ45 Ethernet port 10 100BaseT Ethernet is not supported at this time Connector RJ45 Optional Featur CD S Control panel External control panels available Environmental Equipment will meet guaranteed performance specifications under the following conditions Operating room temperature range 0 Cto 45
2. 31 0 35 62 38 42 1 N Europe 45 45 96 88 70 Germany Austria Eastern Europe 49 6150 104 444 UK Ireland Israel 44 118 923 0499 Copyright Thomson All rights reserved This product may be covered by one or more U S and foreign patents Grass Valley Web Site The www thomsongrassvalley com web site offers the following Online User Documentation Current versions of product catalogs brochures data sheets ordering guides planning guides manuals and release notes in pdf format can be downloaded FAQ Database Solutions to problems and troubleshooting efforts can be found by searching our Frequently Asked Questions FAQ database Software Downloads Download software updates drivers and patches GVGrass valley END OF LIFE PRODUCT RECYCLING NOTICE Grass Valley s innovation and excellence in product design also extends to the programs we ve established to manage the recycling of our products Grass Valley has developed a comprehensive end of life product take back pro gram for recycle or disposal of end of life products Our program meets the requirements of the European Union s WEEE Directive the United States Environmental Protection Agency and U S state and local agencies Grass Valley s end of life product take back program assures proper disposal by use of Best Available Technology This program accepts any Grass Valley branded equipment Upon request a Certifica
3. ferent If both ports are configured as dynamic the port referred as source will be used as a device and the port referred as destination will be used as a controller This makes it possible to use a single bus panel to select one of several machines to control from a single location Router Orientation in D1616 Mode In D1616 mode all ports are fixed port 1 16 as controllers and port 17 32 as devices The control system will see the router as a 16x16 matrix When the router is destination oriented destinations 1 16 are mapped to ports 17 32 while sources 1 16 are mapped to ports 1 16 When the router is source oriented destinations 1 16 are mapped to ports 1 16 while sources 1 16 are mapped to ports 1 16 As in TPS D32P mode this makes it possible to use a single bus panel to select one of several machines to control from a single location Triton Plus Ported RS 422 Data User Manual Configuration Switch SW 9 on the configuration switch defines the router orientation as shown in Table 7 The default setting is Off Table 7 Router Orientation Settings SW 9 SW 9 D1616 Mode Off Destination oriented On Source oriented Future Use Switches 10 17 are currently not in use Ext Address Switches 18 20 are currently not in use Triton Plus Ported RS 422 Data User Manual 13 LED Status LED Status 14 Alarm States The LED located at the front of the router indicates the status of
4. Data Routers are bi directional ports rather than XY A tradi tional 32x32 router will have a total of 64 connectors 32 in 32 out A ported 32 Router will have a maximum of 32 connectors all configurable to be operated either as Controller or Device In the TPS D32P Ported Data Router the terms Controller and Device are used instead of In Out Source Destination I e a Ported Data Router Con troller can be both signal Source or Destination All ports are coupled according to SMPTE 207M machine control standard Triton Plus Ported RS 422 Data User Manual 7 Connection Details Connection Details Available ports and connectors at the back of the Triton Plus TPS D32P data router are shown in Figure 1 and listed below RS 422 connectors 32 device connectors RS 232 Port RS 232 for external control Power Connectors e A x15VDC power input e B x15VDC power input redundant supply NCB IN Network Control Bus input e OUT Network Control Bus output Configuration switches DIP switches for configuration settings Ethernet Not used at this time Figure 1 Triton Plus TPS D32P Ports and Connectors RS 422 Connectors RS 232 port Power connectors Not in use 2 on lt NCB Configuration switches Ethernet Triton Plus Ported RS 422 Data User Manual Power Supply Pinouts Connection Details The DB9 power pinouts for Triton Plus routers and control panels are given in Table 1 Table 1
5. Power Supply Pinouts Pin Number Description 1 GND Not Conn ected Not Conn ected 15 VDC Not Conn ected Not Conn ected Not Conn ected 15 VDC oo BY wr m Not Conn ected Triton Plus Ported RS 422 Data User Manual Configuration Configuration 10 It is possible to use the router out of the box Changes to the factory set tings can be set with the DIP switches found in the back of the router As factory setting the TPS D32P is shipped with Dynamic ports This means every port can be controller or device depending on the connected equipment Configuration Switches You will find 2x10 DIP switches on the backplane of the router see Figure 1 on page 8 Switches 1 4 set the router Level and the Physical Address for this unit By setting routers and Control Panels on same level routers can be controlled as one i e Audio follow Video Panels in a NCB loop must be configured to the same level as the router s The Levels Physical Addresses can be set according to the following pattern given in Table 2 The default level is 1 Table 2 Levels and Physical Addresses Switch Patterns m oe swa om om D omm Off Off Off Off 1 0 Off Off Off On 2 1 Off Off On Of 3 gt Of Off On On 4 3 Off On Off Off 5 1 off On Off On 6 5 Off On On Off 7 6 Of On On On 8 7 On Off Off Off 9 8 On
6. 2 LED Stats cian ed cure a ea nass 14 Alarm States ea ERES Ais E oe eee Nasa dede REC REDE 14 Router Communicator nnn 15 Serial Connection seres serere tusante eea e rere 15 Maximum Cable Length RS 232 16 NCB Connection 22 422 802 HENS uu EX ars Ve ee ened EAs 16 Connecting Control Panels 16 Pinoutand Cable Type 4 isse re ehe er scien seras 16 Termination Plug eee e e eer ber re be EE S es 17 Control Bus Structure si 3 00 rn sas 18 Maximum Distance Between NCB Devices 18 Connecting RS 422 Signal Cables To Data Router 19 ADphCatons en ee etn miento ae 20 Dynamic san WENA We mt veh y Deere ene es 20 Fixed a ner ea less 20 Specifications cies spas sanieren ea ne aan sarees ea ae 21 Triton Plus Ported RS 422 Data User Manual Contents 6 Triton Plus Ported RS 422 Data User Manual Triton Plus Ported RS 422 Data Routers Product Overview Professional broadcast installations often include a number of tape recorders and other devices that require RS 422 machine control for remote operation To meet these requirements Thomson Grass Valley introduces the Triton Plus TPS D32P Ported Data Router Complex installations cable cost and system design is kept at a minimum Where user friendliness and operational flexibility is appreciated the TPS D32P will fit in perfectly The Ported
7. C Operating relative humidity range 9596 non condensing Equipment will operate without damage under the following conditions Temperature range 10 C to 55 C Relative humidity range lt 95 non condensing Triton Plus Ported RS 422 Data User Manual 21 Specifications 22 Triton Plus Ported RS 422 Data User Manual
8. Off Off On 10 9 On Off On off 11 10 On Off On On 12 T On On Off Off 13 12 On On Off On 14 13 on On On Off 15 14 an On On On 16 15 Triton Plus Ported RS 422 Data User Manual Configuration Audio Video Mode The TPS D32P router can be assigned to either the video level or the audio level of a router system selectable with switch SW 5 on the configuration switch If you re using the Data Router in an Audio follow video setting the Data Router can be set as Video giving an Audio follow Data function Breakaway is also possible with this set up Table 3 gives the settings for SW 5 The Default mode is Off Table 3 Audio Video Modes SW 5 SW 5 Router Mode Off Controlled as Audio On Controlled as Video D1616 Mode If The TPS D32P Ported Data Router is to be configured as a D1616 router this DIP switch SW 6 must be ON The TPS D32P will then be configured as 16 inputs 1 16 and 16 outputs 17 32 and will be identical with the existing Triton Plus D1616 Data Router Table 3 gives the settings for SW 6 The Default mode is Off Table 4 D1616 Mode SW 6 SW 6 D1616 Mode Off TPS D32P mode On D1616 mode Power Alarm The Power Alarm is set with DIP switch SW 7 When using a redundant power supply the power alarm should be ON If only one power supply is connected this DIP must be off Settings are shown in Table 5 The default mode is Off The TPS D32P will give an alar
9. Ov crass valley User Manual Revision 5 JANUARY 2009 THOMSON i amp beyond images amp bey nd KEMAX Affiliate with the N V KEMA in The Netherlands CERTIFICATE Certificate Number 510040 001 The Quality System of Grass Valley Inc 400 Providence Mine Road 15655 SW Greystone Ct 10 Presidential Way Nevada City CA 95945 Beaverton OR 97006 3 Floor Suite 300 United States United States Woburn MA 01801 United States Nederland B V Weiterstadt Germany Rennes France 4800 RP BREDA Brunnenweg 9 Rue du Clos Courtel The Netherlands D 64331 Weiterstadt Cesson Sevigne Cedex Germany France Technopole Brest lroise 17 rue du Petit Albi BP 8244 2300 South Decker Lake Blvd CS 73808 95801 Cergy Pontoise Salt Lake City UT 84119 29238 Brest Cedex 3 Cergy France United States France 7140 Baymeadows Way Suite 101 Jacksonville FL 32256 United States Including its implementation meets the requirements of the standard ISO 9001 2000 Scope The design manufacture and support of video hardware and software products and related systems This Certificate is valid until June 14 2009 This Certificate is valid as of August 30 2006 Certified for the first time June 14 2000 fe 7 7 uc K 7A H Pierre Sall President KEMA Registered Quality The method of operation for quality certification is defined in the KEMA General Terms And Conditions For Quality And Environmental Management Systems Ce
10. e as follows e Bit rate 19200 bit s e Data bits 8 bits e Stop bits 1 e Parity No parity For further detail concerning this protocol please refer to the following manual Compact Router Control Protocol The DB9 female connector for the serial port s of the router has the fol lowing pinout Table 9 Table 9 Serial Connection Pinout Pin RS 232 Mode 1 Not in use Tx Rx Not in use GND GND RTS CTS oO col NW BY wy Do Not Connect Note If the standard RS 232 cable specification DCE is followed A cable with Male Male or Female Female connectors at the cable ends is used for Rx Tx crossed connection A cable with Male Female connectors at the cable ends is used for a straight through connection Triton Plus Ported RS 422 Data User Manual 15 Router Communication Maximum Cable Length RS 232 IEEE has specified the maximum cable length for an RS 232 connection to 15 meters Longer distances can be installed depending on the environ mental conditions of the installation site It is the responsibility of the installer user to secure a proper installation of the RS 232 connection NCB Connection Viathe Network Control Bus system several routers and control panels can be interconnected Up to 16 levels of routers or combinations of routers can be controlled The NCB system and all RS 232 ports interchange the system status T
11. his means that any control system either from Grass Valley or from a third party manufacturer connected to any RS 232 port in the NCB loop will have access to all communication data on the bus Connecting Control Panels To get a control panel working with a specific router configure the control panel to the same level as the router Several panels can be configured to control the same router Panels can also be connected to a router via the RS 232 interface Please refer to your control panel manual for installation Pinout and Cable Type 16 Triton Plus routers and Control Panels use RJ45 connectors for the Network Control Bus ports The following pinout shown in Table 10 is used Table 10 RJ45 Connector Pinouts Pin Description Illustration 1 Not Connected Not Connected Data retour Data Data Data retour Not Connected ofl s Dm MO AJ wy n5 Not Connected Triton Plus Ported RS 422 Data User Manual Router Communication The following connection example Figure 2 shows connection of four Triton Plus devices with RJ45 connectors and bus termination Figure 2 Four Devices Connected Together Using RJ45 Note Each device at the end of the chain has a termination plug indicated with the letter T This termination plug must be inserted in the correct connection port If not no NCB communication is possible Termination Plug The termination plug that i
12. m and the front LED will blink red when one of the power supplies connected fails Table 5 Power Alarm Settings SW 7 SW 7 Power Alarm Off Disables power alarms On Enables power alarms Triton Plus Ported RS 422 Data User Manual 11 Configuration 12 Power Up Mode Switch SW 8 on the configuration switch defines the power up mode The TPS D32P router provides two modes for powering up the system e Mode 1 switches all ports as disconnected e Mode 2 switches all ports according to the latest setting buffered in the router s processor system Settings for SW 8 are given in Table 6 The default mode is Off Table 6 Power up Settings SW 8 SW 8 Power Up Mode Off Mode 2 On Mode 1 Router Orientation Crosspoint commands in control protocols are using source and destina tion when controlling routers This must be mapped to ports in the router When controlling RS 422 every port is bi directional and includes both a source and a destination The mapping is different in D1616 mode and TPS D32P mode Router Orientation in TPS D32P Mode By default the router is destination oriented SW 9 DIP is OFF A bi direc tional connection is made between the two ports If both ports are config ured as dynamic the port referred as source will be used as a controller and the port referred as destination will be used as a device When the router is source oriented SW 9 DIP is ON the mapping is dif
13. nnections Table 11 RS 422 Signal Connections Device Controller Pin 2 Tx Pin 2 Rx Pin 3 Rx Pin 3 Tx Pin 4 GND Pin 4 GND Pin 5 Future use Pin 5 Future use Pin 6 GND Pin 6 GND Pin 7 De Pin 7 Rx Pin 8 Rx Pin 8 Tx The RS 422 connectors on the rear of each unit are arranged as given in Table 12 Table 12 RS 422 Connector Arrangement Triton Plus Ported RS 422 Data User Manual 19 Router Communication 20 Applications Dynamic Fixed The first example Figure 4 shows how to connect two Video Tape Recorders VTRs with traditional AV Routers for signal transport and a TPS D32P Ported Data Router for RS 422 Machine Control Both VTRs can be used as Player or Recorder depending on their local remote setting Figure 4 Dynamic Application Example Player Recorder Device Controller Controller Device nd Loss Triton Plus Data router The second example Figure 5 shows a VTR and NLE Computer i e NLE Non Linear Editor The units can both be Player or Recorder for audio and video while the Computer is Controller Master and always controlling the device VTR Slave This leaves RS 422 Machine Control Data to always operate in one mode Fixed Figure 5 Fixed Application Example NLE PC VTR Player Recorder Triton Plus ANN routers Device Controller all Triton Plus Data router
14. rtifications Integral publication of this certificate is allowed KEMA Registered Quality Inc Accredited By 4377 County Line Road ANAB Chalfont PA 18914 ANAB Ph 215 997 4519 Fax 215 997 3809 CRT 001 073004 Ov grass valley Triton Plus PORTED RS 422 DATA ROUTER LL LLL LLL TL LLLI DE ouaaa III TI i i aooaa LI LI LI LI LI LI LI LI LI m L L Lj Lj L Lj L Lj Lj Contacting Grass Valley International France 800 8080 2020 or 33 1 48 25 20 20 United oo Support Centers 24x 7 800 8080 2020 or 33 1 48 25 20 20 24x7 1 800 547 8949 or 1 530 478 4148 Hong Kong Taiwan Korea Macau 852 2531 3058 Indian Subcontinent 91 22 24933476 Asia Southeast Asia Malaysia 603 7805 3884 Southeast Asia Singapore 65 6379 1313 China 861 0660 159 450 Japan 81 3 5484 6868 Local Support Centers Australia and New Zealand 61 1300 721 495 Central South America 55 115509 3443 available Middle East 971 4 299 64 40 Near East and Africa 800 8080 2020 or 33 1 48 25 20 20 business hours Belarus Russia Tadzikistan Ukraine Uzbekistan 7 095 2580924 225 Switzerland 41 1 487 80 02 Europe S Europe Italy Roma 39 06 87 20 35 28 Milan 39 02 48 41 46 58 S Europe Spain 34 91 512 03 50 Benelux Belgium 32 0 2 334 90 30 Benelux Netherlands
15. s mentioned in the previous section is necessary when you want to avoid closing the loop with a long cable The termination plug is a standard RJ45 plug with the following internal wiring shown in Figure 3 Figure 3 RJ45 Termination Plug Wiring 1 8 E Pin 3 is connected to Pin4 34 56 Pinsis connected to Pin 6 Triton Plus Ported RS 422 Data User Manual 17 Router Communication Control Bus Structure The Network Control Bus structure follows the standard MIDI bus defini tion The NCB is defined as a closed chain of units This means that the NCB OUT of the last unit must be connected to the NCB IN of the first unit in the NCB chain To avoid problems with the control of Triton Plus units the installer user has to assure that the bus structure is installed according to this definition Note The total number of Triton Plus devices in an NCB chain is limited to 50 Maximum Distance Between NCB Devices The standard MIDI definition allows a maximum cable length of 200 250 meters between two devices Longer distances can be made with MIDI repeater units To avoid grounding problems all NCB ports have opto cou pled inputs 18 Triton Plus Ported RS 422 Data User Manual Router Communication Connecting RS 422 Signal Cables To Data Router All router ports on the TPS D32P are coupled in accordance to the SMPTE 270M standard This is the broadcast standard for RS 422 machine control Refer to Table 11 for pin co
16. te of Recycling or a Certificate of Destruction depending on the ultimate disposition of the product can be sent to the requester Grass Valley will be responsible for all costs associated with recycling and disposal including freight However you are responsible for the removal of the equipment from your facility and packing the equipment to make it ready for pickup For further information on the Grass Valley product take back system please contact Grass Valley at 800 80 80 20 20 or 33 1 48 25 20 20 from most other countries In the U S and Canada please call 800 547 8949 or 530 478 4148 and ask to be connected to the EH amp S Department Additional in formation concerning the program can be found at www thomsongrassvalley com environment THOMSON images amp beyond y 4 Triton Plus Ported RS 422 Data User Manual Contents Triton Plus Ported RS 422 Data Routers Product OvervieW o oooooooo eh e e ht 7 Connection Details 00 ccc eect tee n 8 Power Supply Pinouts ice eek e evade er E wedded ais 9 Configuration ur ois sdua pede spied Re sat Seed See e en sa cn 10 Configuration Switches 10 Audio Video Mode 11 D1616 Mode me ERR E a he e e aaa LL Power Alarm cL 2 VAR ae Ne A REY nO TI Power Up Mode pintas rd pete 12 Router Orientation sas ersan 4 00 neue 20 e YEA EY ENS 1
17. the router At start up the LED will alternate between red R and green G every 500ms for about two seconds After the start up sequence the LED will indicate the Alarm state of the router The LED can either be red R green G or have no light N The LED state is described in Table 8 below with twenty letters each repre senting 100ms which totals an alarm sequence of two seconds The X indi cates that the LED keeps the color it has the moment the alarm sequence begins green or no light Table 8 LED Alarm States Description LED State Alarm Comment No Alarm Continuous Green Light GGGGG GGGGG GGGGG GGGGG Status OK Long Red Blinking RRRRR NNNNN RRRRR NNNNN Power is too low One Short Red Blink RXXXX XXXXX XXXXX XXXXX Power A failed Only active if power alarm Two Short Red Blinks XXXXX XXXXX RXRXX XXXXX Power B failed DIP is set Triton Plus Ported RS 422 Data User Manual Router Communication Router Communication You gain access to the router for communication purposes by connecting the router s serial port to your computer Serial Connection Connection can by made trough the serial port s of the router see also Con nection Details on page 8 for connection details The communication parameters are configurable Please refer to the pro tocol documentation of the appropriate communication control protocol Example The protocol parameters of the Triton Plus Compact routers ar
Download Pdf Manuals
Related Search
Related Contents
Harbor Freight Tools Pipe/Tubing Notcher Product manual QuickBooks 2006 User Guide ElectronS.R.L. lyon – 23-25 octobre 2014 Copyright © All rights reserved.