User manual for Serial Bridge Art. 20003101

image

Contents

1. LOAD 14 04 2014 gt 8 12 16 20 lt Comelit Connected gt Scenarios nan Scenarios lt Morning Gef Start Tour SCH Relax TV The Shutters section can be used to open or close one shutter or all the shutters in a room 1 Press to access the shutters section 2 Press v to close the shutters in the controlled room and press A to stop downward movement Or Press aA to open the shutters in the controlled room and press wv to stop upward movement The blue bar indicates that the shutters in the controlled zone are working 1 Press to access the shutters section 2 Press a specific room for example DAY ZONE and control the individual elements using Av Press vy to close the shutter and press A _ to stop downward movement Or Press A to open the shutters in the controlled room and press ye to stop upward movement The blue bar indicates that the shutter in the controlled zone is working e The blue arrow indicates whether the shutter is opening or closing This menu can be used for monitoring consumption though graphs and tables al KI Consumption gt Press to access the Consumption menu Scroll through available meters Meter currently displayed Scroll through days months years log Change day month year log mode Change unit of measurement Change graph table display Total consumption val
2. gt CAIGIJCICICIGCIZIGA s E D a ea e a DEI E GAS settings Meter _ GAS Unit of measurement mc 1 00000 Scale factor Setup Consumption Reset Reset count lt 17 14 07 04 2014 Reset meters are you sure No Yes 10 This menu can be used to set the maximum consumption setpoints for hours days months and years in order to obtain an immediate visual comparison on the graph and in the consumption table when the set setpoint for the period is exceeded Yellow 75 of the set setpoint Red 100 of the set setpoint Meter select the meter for which you want to set the setpoints Time Month day Year set the maximum consumption setpoint for the corresponding time interval This menu can be used to set the meter rates according to time bands The information will then be used to construct the consumption graphs in the Consumption menu Home Consumption 1 Meter select the meter for which you want to set the setpoints for example Elect consumption 2 Rates set the rates according to time 3 Time slot set the start and end of each time band and associate the time bands with the corresponding rate for every day of the week CAUTION daily rate programming must refer to the whole 24 hour cycle any hours not programmed by the user will be set by the system automatically This menu can be used to view the settings for the pulse mete
3. This menu can be used to set which consumption values to display on the consumption menu decide which consumption value to display on the homepage change the maximum consumption setpoints by hour day month or year change the rates by day and time band Toolbar select which meter to monitor via the toolbar on the homepage Currency enter the currency symbol you want to set for calculating consumption CO2 constant enter the CO2 constant to monitor the CO2 not released into the atmosphere in the case of energy production systems photovoltaic systems The CO Saved graph can be viewed via Home Consumption HOME CONSUMPTION CO SAVED This menu can be used to rename the meters connected to the system and select the meters that you wish to view in the consumption menu area Description description associated with the meter Visibility makes the meter in the consumption menu visible x lt Comelit Setup Consumption Setpoints Thresholds lt Consumption thresholds Meter consumption H Time kWh Day kwh Month kWh Year kWh Setup Consumption Rates SES Rates lt Rate Electricity production Elect consumption 1 kWh 2 kWh 3 kWh 4 kWh 5 kWh Select a rate Mon Tue Wed Thur Fri Sat Sun Meter Rates Time slot Start End
4. da 3 06 SITTING ROOM D oh ENTRANCE LED We lt Comelit Connected gt lt lt Corr eit NG The Other Lights Irrigation Automations section can be used to control the corresponding elements gt Press Other J D hts ui Irrigation 7 Automations to access the relevant sections and control the zones using the ON OFF commands Element statuses some controlled elements in the room e g DAY ZONE are active all controlled elements in the room e g DAY ZONE are active Irrigation legend Irrigation E 18 gt Press WEN to access the relevant sections press a specific room for example DAY ZONE and control the individual elements using the ON OFF commands timed irrigation If there is an adjustment slider gt move the slider 1 to set the desired intensity If RGB lights are used their colour and brightness can be adjusted gt Click the element you wish to set 2 and select the desired tone on the colour spectrum 3 gt Move the slider to set the desired intensity 4 ERR element oft single active element other outputs legend lights legend timed light Shutter x lt Comelit Shutters ra DAY ZONE an x Comelit Connected gt lt Shutters DAY ZONE a gt KComelif Connected gt Consumption Consumption lt
5. m Sunset variation Enable NTP automatic time date from Internet I User codes 3 Select the menu entry you want to configure Dynamic DNS Advanced Firmware IP address 172 24 2 186 Subnet Mask 255 255 0 0 Gateway 172 24 255 254 Primary DNS 172 24 0 30 Secondary DNS 172 24 0 44 MAC address 00 04 A3 CE D5 75 Connected gt This menu can be used to set the device date and time as well as the Astronomical dawn dusk device Comelit Date and time Date and time the values can only be changed when enable NTP is deactivated Enable NTP automatic time date from Internet enables automatic updating of date and time via the web Only works if the bridge is connected to the Internet Time difference select the reference time difference Automatic switch to DST select Automatic Europe only to set the automatic switch to DST only with enable NTP active select Specify date to specify the time interval in which DST is applied Automatic switch to DST From To dE Astronomical dawn dusk device Sends commands at sunset and sunrise see Setup Advanced Rules according to the latitude and longitude of the installation site to avoid installation of external dawn dusk devices Latitude Longitude set the relevant coordinates for automatic updating of the dawn dusk clock Sunrise variation Sunset variation adjust these values to bring the sunrise and sunset ti
6. default to access all user sections except SetUp and Alarms without sections except SetUp and Alarms without entering the user password A user password entering the user password It is nevertheless should nevertheless be set for accessing the necessary to know the VEDO control panel Setup and Alarms sections user code configured via Safe Manager in order to access the Alarms section and set a password for accessing the Setup section serial bridge user code to access all user serial bridge user code to access all user sections sections except Alarms It is nevertheless necessary to know the VEDO control panel user code configured via Safe Manager in order to access the Alarms section VEDO control panel user code to access all user sections using the VEDO user code configured via Safe Manager default 111111 gt To set a new user code enter a new password and press Save This menu can be used to associate a dominion name for remote connection with the public IP address of the Serial Bridge Art 20003101 1 Enable DDNS service tick this option to enable the DNS service 2 DNS service select for example Comelit DNS to use the free Comelit service 3 Press Comelit DNS registration and complete user registration making a note of the data entered on the website www comelitdns com to which you are automatically directed You must be connected to the Internet to carry ou
7. Press to return to the previous screen Comelit Connected gt 5 The menu icons change depending on the type of system installed and the functions available To navigate the menu simply press the icon corresponding to the desired function The icons on the home screen provide feedback on the status of the active elements within the relevant section Status of the icons on the home screen no active element some active elements Un all elements active Scenarios x lt Comelit Status of the alarm icon on the home screen CON NGA NGA UAN NGA Alarm Alarm Alarm Alarm Alarm Alarm deactivated Alarm activated across Alarm partially activated Sabotage fault Alarm memory In alarm across the entire system the entire system only a few areas and or a few partial settings are active The Alarm section can be used to activate deactivate and view the status of the alarm system areas OH Alarm lt This chapter illustrates alarm section operation for VEDO series control panels The display looks 4 different for S series control panels 1 1 Alarm system status icon System Deactivated d Sc ei bk p2 TE P142 s Bo P r System Deactivated System Activated SE E ATM Alarm partially activated Fee Alarm deactivated Alarm activated across the entire JJ 2 system only a few areas and or a few partial settings are active di ez Gn Ge NG A a A a Alarm in progress bg prog In eabotaoe A
8. USER MANUAL 20003101 BI _ sneus0 Wa Home SERIAL BRIDGE 0 ve 0 gt H ve m a m 0 SNLVLS Y3MOd cl St gt PsP mm nw m m AA e OI User manual for Serial Bridge Art 20003101 www comelitgroup com Comel lit Bea Passion ond Innovation come NG INDEK OT OC CO EE 3 ACCESS EO WOD DAG TE 3 Description OF TING En CT 3 Alarm for VEDO control panels EE 4 KEEN 5 Other Lights Irrigation At Fotoe gbeeeugeedeuCu Eege nnmnnn nnmnnn nnmnnn nnnm 6 TEE 7 COPS TOMI eege 7 SOO E 7 SO UU EE 8 ocup Dale and TIME ege 8 SER aE e E 9 OCUP CONSUMI O saran aii aaa A E E E TE 9 EIERE eege 9 SUMS Sr SION Ee 10 DEIN CONSUIMDUONS TT 10 Setup GCONSUMPUON 1 SENG EE 10 Sep COMSUMPNON A MESEI sasagaran aaa EE 10 SENI USE a 0 ak samba aa ab an nabi a kran aa aaa akan a naa a aaa aa eo eaaa alaba a aa aaa baan jaan aa ee nara ika a ee eee eee 11 SEI ee 11 x lt Comelit The multifunctional Serial Bridge module makes it possible to communicate with the SimpleHome home automation system and with S Series and VEDO anti intrusion systems It can be used as follows Weekly schedule programming sends commands to outputs zones scenarios and thermostats within the system Rule management programs logic rules for the generation of an event Scenario management programs scenarios for sending commands to the SimpleHome automation system and or the S Series or VEDO securi
9. ific a specific area across the area open omitted area isolated sabotaged faulty in m alarm in fault Indicates that the alarms are active Indicates that the system is not ready for activation and forcing is required Climate KCOMelif zone status legend E zone oO Zone faulty Zone isolated EH Zone excluded el Zone in standby Zone in sabotage BEDROOM xComelit O1 LIVING ROOM 23 62C De Drv Activates partial 1 across a specific Activates partial 2 across a specific Activates partial 1 and 2 across a area and deactivates partial 2 if area and deactivates partial 1 if specific area o Indicates that the partial sets are Indicates that the partial set is Indicates that the partial set is active active oo Indicates that the system is not Indicates that the system is not Indicates that the system is not ready for activation and forcing is ready for activation and forcing is ready for activation and forcing is required required required SE Intrusion Zones Jl gt Press Oz to view the status of zones in an area lt Area 1 gt gt Usel lt gt to scroll through the system partitions IN Entrance door gt Press an entry on the list e g Entrance door to omit or isolate the zone Comelit Connected C gt The climate section can be used to monitor and adjust room temperatures gt Pre
10. larm Memorv Area 2 SEN Alarm in memory alert Alarm in progress System in sabotage xComelit Connected gt 1A Alarm control buttons for the entire system Sc Deactivates the alarms activated Displayed the status of zones Activates the alarms across the across the entire system across the entire system open entire system omitted isolated sabotaged faulty in alarm CES Pe Activates partial 1 across the entire Activates partial 2 across the entire Activates partial 1 and 2 across the system and deactivates partial 2 system and deactivates partial 1 entire system if active if active H Alarm J gt Press Zones to view the status of zones across the l entire system lt Zen gt gt Use to scroll through the zone statuses open omitted isolated sabotaged faulty in alarm e Entrance door gt Press an entry on the list e g Entrance door to omit or isolate the zone xComelit Connected gt man Zone alarm status bar kt Deactivated Total Act Zone alarm deactivated Zone alarm activated Partial zone alarm activated Area 1 Area 1 Area 1 In sabotage Alarm memory Alarm in progress Area in sabotage Zone alarm in memory alert Alarm in progress 2A Alarm control buttons for an area Ome Intrusion Zones Deactivates the alarms activated in Displays the status of zones Activates the alarms for a spec
11. mes forward or set them back For example if you want to switch on the outside lights at sunset leave the sunset variation at 0 If you want to switch them off 2 hours before sunrise set the sunrise variation to 120 min x lt Comelit Setup Timer enabling nun Enable Timers lt Day timer Timer number 2 Day el Timer enabling d Timer start HH MM 00 00 Enabled days MMo MTu MWe Th MFr MSa MSu Timer End HH MM 00 00 Enabled days MMo MTu MWe MTh M Fr MSa MSu Setup Consumption Consumption Display Thresholds Rates Reset Consumption a ae lt CO Saved gt bridge lt 14 04 2014 gt Toolbar AA 077042044 0 00kW na GE Ga Okg Currency CO2 constant kg 8 E a Setup Consumption Display H Display meters Description Visibility Electricity A Gas E Water m Input 2 E Input 3 E This menu can be used to activate deactivate the programmed timers and change timer operating times days Timer number select the timer you want to activate orogrammed via Setup Advanced Timers Timer enabling enables the selected timer Timer start timer start time The timer start times can be changed Enabled days days on which the timer will be started The timer operating days can be changed N B with the virtual timer the Timer end times can also be changed
12. r module used to measure water GAS etc Meter select the meter for which you want to change the settings Unit of measurement enter the unit of measurement for that meter Scale factor enter a multiplication factor if you want to convert different units of measurement for example from litres to imperial gallons 4 54609 This menu can be used to reset all meters gt Press Yes to reset all meters x lt Comelit Setup User Codes Change codes Home automation login New user code Re enter user code lt xComelit Connected gt CC Setup Dynamic DNS uuu Dynamic DNS lt DNS client not enabled Enable DDNS service E DNS service Comelit DNS registration DDNS code 0004A3CED575 Activation code C557E350907E74A2 Username indicate service access username Password indicate service access password Host indicate dns name Ir KComelif Connected gt 11 This menu can be used to change the user code v The code can consist of letters a z capitals or lower case and or digits 0 9 v The password is case sensitive a difference is detected between capitals and lower case letters V Min length 4 characters Max 10 characters Home automation login the drop down menu can be used to set the Home automation login as S series control panels VEDO control panels no user code default to access all user no user code
13. ss to access the Climate menu gt Press the desired room for example BATHROOM Room temperature 4 2 Boiler air conditioning Zon indicator 3 Room displayed 4 Automatic mode 5 Manual mode 6 Forcing of timed custom mode 7 Room temperature adjustment slider 8 Desired temperature 9 System on off 4 0 Summer winter mode selection cooling heating management OFF gt Press system on to change the status to system off and vice versa I S a gt Press summer mode ez to switch to winter mode and vice versa gt Press the H icon to set the climate to manual mode and use the and selectors or the adjustment slider to adjust the temperature of the room The icon will turn blue gt Press the A icon to set the climate to automatic mode and use the programming set on the master supervisor The icon will turn blue indicates that timed custom mode has not been activated on the master supervisor indicates that timed custom mode has been activated on the master supervisor A options Automatic mode Manual mode and Forcing timed custom mode are not available if the Serial Bridge is set as a main device MASTER Other Lights Irrigation Automations Lights lt OFF Day ZONE on OFF teja nge W EEGEN x Comelit Connected gt Lights lt DAY ZONE gt OFF ENTRANCE LED SITTING ROOMMED
14. t this procedure User registration Hostname l myhostname comelitans com Email address user comelit it N lt Password M have read the terms and conditions of service KE gt 4 Press gt to register the product A confirmation email will be sent to the email address entered during the user registration process follow the instructions in the message to complete the activation procedure 5 Return to the Serial Bridge WEB page and enter the email address used for registration the password and the submitted hostname in the Username Password and Host fields 1st edition 05 2014 code 2G40001101
15. ty system Management via browser allows the user to directly access the security and home automation systems from an internet browser in order to control the security system or the automation system by means of simple commands Configuration must take place via the WEB interface To access the Web pages via browser from PC tablet smartphone Local connection 1 Open your browser 2 Enter the address 192 168 1 252 or the IP address provided by your installer in the address bar and press enter 3 If requested enter the user password provided by your installer default 111111 and confirm Remote connection 1 Open your browser 2 Enter the hostname provided by your installer e g XXXXXX comelitdns com in the address bar and press enter 3 If requested enter the user password provided by your installer default 111111 and confirm eoo NETES ANNA comelitdns com Current page header Date and consumption toolbar 3 Buttons for accessing the internal pages used to view and control the available functions and to configure the device lr 3 4 Connection and authentication status message connected not authenticated not authorised Other 5 Logout button Q i l Shutters Lights E gt Press Alarm Climate Other to access the respective sections A gt Press BER to return to the initial screen jali etup bridge 1 17 14 07 04 2014 0 00kW ___ 2 T A gt
16. ue for the displayed graph Instant load consumption value lf the maximum consumption setpoints have been set see Setup Consumption Setpoints the consumption limits are displayed e In graph mode yellow line from 75 to 100 red line over 100 e In table mode the check boxes are coloured to indicate the consumption level from 0 to 75 from 75 to 100 over 100 The Scenarios section can be used to activate programmed scenarios gt Press the scenario to activate it Reverie the blue bar indicates that the scenario is being executed x lt Comelit Setup 17 14 07 04 2014 bridge Enter User Password LC This menu can be used to configure the date and time enable timers configured via Setup Advanced set consumption setpoints and rates change the user code set a dynamic DNS address and access advanced settings Date and time Enable Timers 1 Press Setup to access the menu 2 Enter the user password default 111111 Consumption j and confirm Setup Date and Time Date and time Date and time DD MM YYYY HH MM Date and time Time difference GMT 1 00 Rome Brussels Copenhag Automatic switch to DST Automatic Europe only Astronomical dawn dusk device Sunrise 06 34 Sunset 20 05 Use the stop as a decimal point Latitude 45 8782 Ju Longitude Sunrise variation So Oo Ko N 3 R 5 be lt gt