Home
WS440 Voice Station Informing Apparatus for Elevator
Contents
1. Fax 54500440 Technology Supporting 021 64802098 User Name Adress Tel The Assocation Zip Fax Quality maintenance notice Maintence Card Dear users Hello The WS440 Voice Station Informing Apparatus for Elevator of you are putting to use our company make the assurement and illustration following 1 The Inspection standards of manufacting and production The manufacting and production of the apparatus has been tested GB7588 1995 Edition ISO9002 1994 and so on 2 Maintence Date The product s maintence date is one year from the date of production If you can not uee the product becase of the quantity problem during the maintence date our company are responsible for maintaining it out of charge Then please shear the notice along the line and post back our company including the trouble artical of the product 3 Avoid responsibility If the product are being breakdown becase the user don t install adjust put to use according to the order in the User Mannual it is excetpt to the maintence date The trouble except to the maintence range but during the maintence date or the requestments after the maintence date our company will still be responsible for it But we will change some fare refer to the material up to the condiction Article Type Code of Production The Place of Installment Indiction of the Trouble User Name Association Adress Zip Tel Fax
2. WS440 Voice Station Informing Apparatus for Elevator USER MANUAL Shanghai Wenshang Innovation Technology Co Ltd WS440 Voice Station Informing Apparatus for Elevator SOSOOOOOCOOCOOCOOSOSOOOOOOOCOOCOOOE Content 1 Summarization ecocococoooooooooooooooooooooooo oo Ol 2 Installation and wiring eccocooooooooooooooooooooo 02 3 Attached drawing ecocoocooooooooooooooooooooooo oo 05 4 Certificate of quality of product s sssssesseeseeecere 10 5 Information feedback table of user eeeeeeeeeeee 6 Quality recognizance eeoeeeeeeeeeeeeeeeeeeeeee ee ee 12 1 Summarization Large scale integrated chips special for speech and large capacity digital memory are applied to WS440 It can meet different needs of voice quality in different situations Its reporting ranges up to 64 storey It has such features as flexible interface reliable operation and strong anti interference Besides station reporting WS440 can report the running direction and broadcast background music too We can customize voice station informing apparatus of foreign language broadcast propagandistic advertisement and the units departments and operation function of each storey according to the requirements of users 2 Product Model WS440G General type It can report the storey serial numbers and running directions of the elevator and broadcast the background music WS440S Special type It can c
3. al communication OTIS Elevator and so on Up leveling A e Leveling leveling switch Direction m Direction chang paec switc Norm level Change pace reser switch Reset Signal voltageE OV Arrive signal E port change Arrive signal 0V pace the elevator power CERTIFICAE ARTICAL Voice Station Informing Apparatus for Elevator TYPE WS440 SERIAL NO THIS APPARATUS HAS BEEN TESTED TO FIND TO BE IN ACCORDANCE WITH THE TECHNICAL REQUIREMENTS NSPECTOR INSP DEPT DATE OF PRODUCTION THE PEOPLE S REPUBLIC OF CHINA SHAGNHAI WENSHANG INNOVATION TECHNOLOGY CO LTD Consumer Information Feedback Table Article of Type WS440 our company Article of eo voltage V auxiliary Parameter storey elevator The place of installment and employing Province urban Time of being employed of the article of our company From Year mont to days The situation after using the product of our company The failure influnces the elevator to function normally the indiction usually happens_ times The main cause of the indiction Your judgements to our company s quantity Your suggestions or different opinions to our company s artical Please post to 588 Gumei Road Caoheing Hi tech Park Shanghai Shanghai Wenshang Innovation Technology CO LTD Zip 201102 Selling Sales 021 64802658
4. connection of the range order of the port with 8241 coding signal of the station informing apparatus The serial Coding The serial Coding number of Code name 8241 number of Code name 8241 port port 1 a L1 1 1 g H1 16 2 b L2 2 6 bl H2 32 3 e L3 4 7 el H4 62 4 f L4 8 g1 H8 The common port of signals above can be either the anode port of the signal electric power or the cathode one It is all connected with the 12th bit of the com port of the station informing apparatus C Other parts are regarded as empty port and needn t connecting 3 The approach of the connection of the station informing apparatus with the elevator operating by serial communication Look at chart 5 A The approach of the connection with SanLing Elevator Look at chart 5 1 Connect the signal of up leveling switch to the port of the station informing apparatus of the elevator and the down leveling switch to the port b 2 Arrival signal is connected to the port stop stop of the station informing apparatus 3 Add up a reset switch or teminal reposition switch on the leveling location of the norm level the first level and then connect it to the port f of the station informing apparatus thus avoiding the misinformation which is resulted from exterior interfere 4 The common port of signal of hatchway leveling switch and norm reset switch is connected to the port com and other empty port is not connec
5. he background music while ordering for example but after finishing installation and utilizing in spot they don t want it they can take part the station informing apparatus and take out the electric circuit board then jump out S1 upright on the electric circuit board Chart 3 7 section port connection chart Signal voltage E ie arrival signal E arrival signal OV the single number of displaying the decile of displaying direction close the door common port changing pace power Chart 4 Binary system coding or BCD coding Connection chart Signal voltage E arrival signal E arrival signal OV low displaying high displaying direction close the door common port changing pace stop the elevator Chart4 A The connection chart of the binary system coding with STEP ELEVATOR control cabinet low displaying high displaying common power Chart 5 Connection chart of the elevator by transportation of serial communication MITSUBISHI Elevator and so on Up leveling Hatchway leveling leveling switch Down leveling a norm level reser switch Signal voltageE OV Arrive signal E Arrive signal 0V Chart5B Connection chart of the elevator by transportation of seri
6. hode look at chart 3 A The a b e f g port of the station informing apparatus should be connected with 5 section signals of 7 section numeral tube signal which displays the single number of storey bl cl g1 should be connected with 3 section signals which displays the decile number of storey B Stop stop is the signal of changing speed arrival It is the triggering signal of the station informing apparatus and is usually essential to be connected Up and down are the signals of running direction Close is the door closing signal Whether these signals are to be connected depends on the requirements of users When connected if the station informing apparatus receives door closing signal close and direction signal up after informing each storey it will inform up If receives door closing signal and direction signal down it will inform down direction If the signal isn t connected the station informing apparatus will not inform up or down C The common port of signal is connected with the com port of the station informing apparatus 2 The connection with the elevator which uses binary system or BCD A The products of Shanghai DiSeng ShengYang FuShi and other kind of elevators which use XINGSHIDA control cabinet can refer to Chart 4 B Put the port a of the station informing apparatus on the lowest and then put it up in turn Setting the example of 8421 the following chart lists the corresponded
7. is the stroke of 7 section numeral tube signal look at table one If operating in other ways of coding or by transportation of serial communication the input signal and the definition of the port of the Station Informing Apparatus will be different Look at each wiring diagram for details So before installing the Station Informing Apparatus you should make definite the type and way of storey displaying of the elevator then take up installing and wiring referring to our wiring diagram relevant in this manual a f b aot WS440 g 220V 220V Station Informing c Apparatus d Chart 1 the stroke of 7 section numeral Chart 2 power input isolation tube signal 5 The directions of installation and wiring 1 The place to install The station informing apparatus is usually fixed on a suitable place on the top of the cage All the signals are inputed from the signal box which is on the top of the cage 2 Working power The working power of the station informing apparatus is 220v altemating current If the working power inputed is seriously interfered then we must add an isolation transformer whose electric power is 5 10VA and 1 1 between the station informing apparatus and the input power Look at chart 2 3 The approach of the connection between the station informing apparatus and the elevator 1 The connection of the elevator which uses 7 section numeral tube signal It has nothing to do with the connection of anode and cat
8. ted B The connection with elevator OTIS Look at chart 5B 1 Connect the hatchway leveling switch signal to port a of the station informing apparatus and up signal to port b Changing pace signal can be connected to port e or port stop stop which depends on the spot 2 Add up a reset switch or teminal reposition switch on the leveling location of the norm level the first level and then connect it to the port f of the station informing apparatus thus avoiding the misinformation which is resulted from exterior interfere 3 The common port of leveling direction changing pace and reset signal is connected to the common port com of the station informing apparatus 4 Other parts are regarded as empty port and needn t connecting 4 Other special ways of connection As the communication port of the elevator does not reach a united standard home and abroad and the way of storey displaying is quite different the station informing apparatus can t be matched to the elevator in a united way of equipping parts of special elevators don t have the stand clock thus regarding door opening signal or break signal as arrival signal and some other parts of elevator users ask for broadcasting voice when it closes If the special ways of elevator connection doesn t fit to the wiring diagram above a special wiring diagram will be enclosed herewith for you 5 Adjusting the background music If users asks for broadcasting t
9. ustomize special function according to the requirements WS440C Communication type By transportation of serial communication 3 Technology Parameter 1 Working electric power AC220V 50HZ include sound box 2 Input signal DC or AC according to specific requirements of order 4 Input signal In order to ensure strong anti interference optoelectronic isolation is applied to the input lead of this station informing apparatus Input signal can be taken from seven section numeral tube signal binary system coding signal or other form of storey signal which displays storey in lift car It can meet different needs of elevator high level input efficiency same cathode or low level input efficiency same anode direct current signal or alternating current signal As for seven section numeral tube signal the definition of input and output signal and the port of the station informing apparatus as follows The serial The serial Code name Definition Code name Definition number of port number of port 1 a 9 up up 2 the single number 10 down b displaying of down direction storey 3 11 door closing e close signal 4 12 common f com signal port 5 g 13 stop change speed and stop 6 bl 14 stop the elevator the decile 7 displaying of 15 el isplaying o 220V eis storey Swer 8 gl 16 0V p The a b bl e el f g gl in the table above
Download Pdf Manuals
Related Search
Related Contents
NEC CLOUD STORAGE User Guide - T SpectronIQ PD-3000HD User's Manual Handbuch NetConnect Premium V1_02 2010-07-06 Catskill Craftsmen 89095 Instructions / Assembly Guide du forum - Carrefours pour l`emploi TE 76 / TE 76 P TE 76-ATC TE 76 P-ATC MxxxL2 Series Operation Manual MANUAL DE INSTRUCCIONES Cooler Master V700 USB-/Internet-Funk-Wetterstation Copyright © All rights reserved.