4000 Brochure
Contents
1. General purpose model MAX 6 000rpm MAX 5 350xg High Speed model MAX 16 000rpm MAX 23 470xg 4000 General purpose model Maximum Speed 6 000rpm Maximum RCF 5 350xg OT The table top centrifuge can centrifuge 68 x 15 mL tubes 16 x 50 mL Conical tubes or 4 x 250 mL bottles It was developed for use as a general purpose centrifuge The 4000 4200 models share these features E Simple design and operability E The chamber opening is 27 5 cm high and 38 cm wide full open type Samples can be easily inserted and removed mw An automatic interlock lid is employed Patent pending The lid automatically locks when closed and automatically opens when rotation stops m The operating status lamp on top of the lid can be seen at a distance Seven lamp colors are user selectable Patented E Five different buzzer sounds indicating the end of operation can be selected and the volume can be adjusted A viewing port is employed so that rotation of the rotor can be observed This can also be used during GMP inspection Centrifuging is possible with the samples just balanced by eye Not applicable when using swinging bucket or fixed angle rotors at 5 000 rpm or higher Conditions for centrifuging can be set and displayed in two ways i e g s RCF and rpm speed Settings for the rotation radius can also be changed which helps obtain a precise RCF di
2. 00rpm 4000 0 to 16 300rpm 4200 10rpm increments Digital display From 20 to 5 350xg 4000 20 to 23 470xg 4200 10xg increments Digital display From 0 to 5 900xg 4000 0 to 24 360xg 4200 10xg increments Digital display with Hold from 1 sec to 99 sec in 1 sec increment setting indication from 1 min to 99 min in 1 min increment setting indication from 1 sec to 99 min 59 sec combination setting indication of minutes and seconds Memory flushing for spin down 5 types and No Sounding Volume Large Small 7 types and No flashing Model 4000 115V 6 6A 220V 3 5A 230V 3 4A Model 4200 115V 7 5A 220V 3 5A 230V 3 3A 560W 2 0MJ h 4000 550W 2 0MJ h 4200 Single phase AC115V 10 50 60Hz 15A Single phase AC220V 10 230V 10 50 60Hz 8A 44 W x 56 D x 31 H cm 36kg 4000 38kg 4000 CE marking 38kg 4200 40kg 4200 CE marking IEC 61010 2 020 All specifications and external appearance subject to change without notice On Model 4000 4200 only use KUBOTA made rotor adapter and tube rack Do not attempt use rotors adapters or tube racks made by other manufacturers The rotor mentioned in the catalogue is usable on other KUBOTA centrifuge models For details refer to the catalogues relevant to each model Follow instructions given in the relevant Instruction amp Service Manual for operating centrifuges BE URL http www centrifuge jp Kubota has acquired ISO 9001 and ISO 13485 certif
3. 12 x 0 2mL PCR 5 90 6 3 x 20 24 16 000 16 890 24 x 0 4mL 5 40 6 1 x 26 48 16 000 23 180 055 7580 12 x 0 5mL 70 7 9 x 25 34 16 000 19 180 This rotor is not tool less rotor 24 x 1 5 2mL 9 50 11 x 36 42 16 000 23 470 AT 2730M eee Tube size mm Adaptor ominal Capacity diam x length Maximum Speed Maximum RCF Maximum Speed Maximum RCF Code No mm Xg mm Xg J 14 x 0 2mL PCR 5 90 6 3 x 20 24 lt 14 000 16 430 Autoclavable at 134 C 30 x 0 4mL 5 40 6 1 x 260 48 14 000 20 380 055 1240 This is a bioshield rotor Samples will not leak out from the rotor even if the 14 x 0 5mL 70 7 9 x 25 34 14 000 17 530 tubes break It has received accreditation from the C A M R of the UK 30 x 1 5 2mL 9 50 11 x 360 42 14 000 21 040 Fixed angle rotor l Tube size mm 2000 Adaptor Nominal Capacity diam apt petal Maximum RCF ar Maximum RCF sar Xg Xg AT 508C T w 015 15 80 16 5 x970 120 6 000 5 110 6 000 5 110 055 1120 plastic g ji 8x14mL_ 1016 17 x 100 6 000 4 990 6 000 4 990 055 0550 ba we 8 x 15mL Conical tube 17 x 121 6 000 5 270 6 000 5 270 055 1280 8 x 50mL plastic 227 26 40 287x980 115 6 000 4 990 6 000 4 990 055 1110 J Te 8 x 50mL Conical tube 30 x 117 6 000 5 350 6 000 5 350 U kaai 16 7 x129 5270 6000 5 2
4. 70 055 1280 Vivaspin 6 O Vivaspin 20 30 x 117 5 350 6 000 5 350 I Amicon Ultra Free CL 16 3 x77 4 270 6 000 4 270 055 1330 I Amicon Ultra 4 17x 129 5 270 6 000 5 270 055 1280 J Q Amicon Ultra 15 30 x121 6 000 5 350 6 000 5 350 Specifications Model 4000 4200 Maximum Speed Maximum RCF Maximum Capacity Drive system Control system Acceleration Deceleration Alarm display Speed setting Speed indication RCF setting RCF indication Timer setting and indication Sounds for informing centrifuging stop Colors of lamps to inform centrifuging condition Rated voltage and Rated current Power consumption and Heat output Power requirements Dimensions Weight Certificates of conformity CE Marking 6 000rpm 4000 16 000pm 4200 5 350xg 4000 23 470xg 4200 1 020mL Direct drive Direct connection with brushless motor Micro processor control Brushless motor Speed RCF Time Acceleration amp Deceleration 5 channel memories Acceleration 2 level selections Rapid and Slow Deceleration 3 level selections Rapid Slow and Natural deceleration Lid open Imbalance Over speed Rotor mounting abnormally Function for detecting an occurrence of electrical abnormally in motor inverter speed sensor Digital display From 300 to 6 000rpm 4000 300 to 16 000rpm 4200 10rpm increments Digital display From 0 to 6 3
5. ated on the right in blue Flow Cytometer 17 x121 17 x121 17 Ke 12t 3 500 3 500 3 500 3 500 2 200 2 340 2 2 0 2 300 Bucket Code No Bucket Code No 053 5840 053 5840 055 1160 053 7130 053 4980 This convenient tube rack can accommodate blood collecting tubes of various sizes such as 5 mL 7 mL 10 mL as well as 15 mL glass tubes J E 61 x 118 61 x 130 61 x 137 600 61 8 x 1000 134 4 600 61 8 x 1000 134 4 cap size 480 31 cap size 48 0 12 cap size 37 cap size 31 3 500 3 500 3 500 3 500 3 500 3 500 2 330 055 4850 2 380 055 4850 2 290 2 260 2 250 055 0430 2 300 055 0450 can be used without adaptors can be used without adaptors OOO COO oO OO g The maximum speed and maximum RCF of ST 504M indicated in the brackets 055 5760 Anti biohazard sealing adapter For use with 50mL Conical tubes NFR BW PREP RPRPRPRrPrPOONOAU NOUBWNEF OO 05 055 4310 Anti biohazard sealing adapter For use with 50mL Oak ridge tubes g6 055 7400 Adaptor for 15mL glass tube Equipped with sealing cap patent pending bd g6 024 1400 Rubber c
6. e optional _ Bucket Code TA Bucket Code No Nominal Capacity F Tube size mm diam x length Swinging m e a E Maximum Speed rpm bucket rotor E E A a Maximum RCF xg xg Tube Rack Adaptor Code No Bucket Code No 053 5820 Buckets are optional Tube Rack Adaptor Code No Bucket Code No 053 0020 Sealing caps and O rings Code No 055 0964 Buckets are equipped with rotor Sealing caps are optional 36 x 1 5 2mL 950 11 x 360 42 48 x 1 5 2mL 9 50 11 x360 42 9 50 11 x360 42 12 50 13 3 x 46 110 12 50 13 7 x 62 110 Tube Rack Adaptor Code No No j 4 800 3 500 3 500 3 500 3 500 4 250 1 880 2 290 2 300 055 4800 Bucket Code No Adaptor Code No pis B 055 0260 055 1190 053 5040 The maximum speed and maximum RCF of ST 722M indicated on the left in The maximum speed and maximum RCF of ST 2504MS indicated on the right in blue Buckets and sealing caps are optional _ Tube Rack Adaptor Code No Sealing caps and O rings Code No 055 0964 D Ss 4 x 100mL 4 x 100mL 4 x 175 225mL glass glass Conical bottle 38 46 5 x 83 120 38 46 5 x 113 120 61 x 118 61 x 137 3 500 4 800 4 800 2 330 4 250 4 250 055 4770 055 1200 055 1200 The maximum speed and maximum RCF of ST 722M indicated on the left in The maximum speed and maximum RCF of ST 2504MS indic
7. ication Products in this catalogue are designed for use by people having the requisite technical knowledge and must always be used with care People who do not have adequate technical knowledge or training should use our products only under appropriate supervision or else hazards are likely to occur The rotor or bucket appears to be damaged or corroded e The defined lifetime of the rotor expires The equipment emits a burnt smell e You receive a minor electric shock when you touch the equipment with your bare hand Any other abnormality or indication of failure is noticed In the event of any observed abnormality in the equipment or its parts to prevent occurrence of functional failure or accidents immediately turn off the power switch disconnect the power cable plug from the mains socket and contact your local distributor or Kubota Corporation if there is no local distributor in your neighbourhood Always discontinue use if any of the DISCONTINUE Conditions listed at USE right are evident INDICATIONS For your safe use of the equipment be sure to read the instruction manual carefully before you start operations Do not misplace the instruction manual Keep the instruction manual nearby so you can refer to it whenever necessary Safety Precautions e Spare parts for repair are typically available for a period of 10 years after production is discontinued except when spare parts cannot be p
8. ode No 352006 352018 352059 Nalgene plastic tube Code No 3110 0500 No 3110 9500 No 3117 9500 SS 07 055 1280 Adaptor for 15mL conical tube 15mL 50 mL 4x5 L 50 50 mL tube cal tuk tul Ol tube 17x121 27 38 x 1000 110 27 36 4 x 85 j 110 270 36 4 x 85 110 27 38 x 1000 110 30 x117 30 x117 30 x117 30 x117 3 500 3 500 5 000 3 500 4 800 3 500 5 000 3 500 4 800 3 500 3 500 2 330 2 270 4 640 2 200 4 150 2 380 4 860 2 260 4 250 2 380 2 330 055 4780 055 6070 055 1170 053 5010 053 0040 053 5020 053 4970 KUBOTA 4000 4200 The number of times allowed for autoclaving are limited Please refer an instruction manual Plate size mm Bucket Micro plate rotor Test plates Nominal Capacity diam x length Maximum Speed Maximum RCF Maximum Speed Maximum RCF Code tic PT 21M du x9 i x9 wil EEE 2 x PCR plate 6 x micro plate 013 86 W x 128 D x 62 H 3 100 5 000 3 100 Equipped with rotor 2 x deepwell plate g0 13 Autoclavable at 121 C Plate size mm Adaptor Nominal Capacity dian ey Maximum Speed Maximum RCF Maximum Speed Maximum RCF E pm Xg pm Xg 2 x PCR plate 8 x micro plate Is 86 W x 130 D x 89 H 1 080 2 400 1 080 Qi 055 6370 914 4 x deepwell plate 0 13 Tube size mm 40900 4200 Adaptor Nominal Capacity diam x length tla acd RCF ale tas patel RCF Code No
9. rocured e This catalogue is not for distribution in the USA Canada or Mexico as the products shown are not for sale in these countries KUBOTA CORPORATION http www centrifuge jp 29 9 Hongo 3 chome Bunkyo ku Tokyo 113 0033 Japan Tel 81 3 3815 1331 Fax 81 3 3814 2574 E mail f trade kubotacorp co jp Copyright 2011 KUBOTA CORPORATION M MAR Printed in Japan
10. splay ve centrifuge comes with a function that allows a delayed start from when the samples are set Patent pending The delayed operation start is particularly useful for serum separation pe timer can be easily set to the desired combination of minutes and seconds When setting the timer to 5 minutes 30 seconds for example there is no need to convert this time interval to 330 seconds for input For example To set 3 minutes 30 seconds To set 5 minutes 40 seconds 210 seconds 340 seconds 3 minutes 30 seconds 5 minutes 40 seconds Compared to other conventional company units Conventional setting method New setting method There is a memory flashing function for easy spin down operation Patented The duration of the spin down operation from 1 to 99 seconds is automatically memorized At the next operation simply pressing a convenient key will start the spin down operation for the memorized duration Compact design Since the centrifuge cabinet has a shorter depth there are more options for device location a Free run can be used for the deceleration curve according to the sample and objective Due to the direct drive and a brushless motor free run natural deceleration applies smooth deceleration providing a clear separation plane rpm e For the slow acceleration the characteristic Speed changeover speed Na can be set from 0 to
11. t 121 C and a fixed angle rotor that can be autoclaved at 134 C Biohazard proof swinging bucket rotor ST 2504MS is rated for 4 800 rpm 4 300 x g Sealing caps optional can be used which are effective for separation of acid fast bacteria A lightweight fixed angle rotor AT 508C accommodating 8 x 50 mL Conical tubes has been developed The RCF which is important for separation is as much as 5 350 x g Compare the RCF with others The design has been developed to accommodate the recycling of materials Parts made of resin materials are marked so that they can be easily sorted The unit shown in the picture is used with the combination tube rack Code No 055 0880 for various size of blood collection tubes A table with casters for mounting the centrifuge Code No 047 3830 It has 2 drawers which are convenient for storage and can be fixed with an adjuster 50 W x 55 D x 53 H cm Rotor Bucket Tube Rack Table for Model 4000 4200 Nominal Capacity ae Tube size mm diam x length Swinging ETE E RETE E Maximum Speed rpm bucket rotor e e Maximum R RCF x g Bucket Code No 053 5820 Buckets are optional Tube Rack Adaptor Code No Bucket Code No 053 0020 Sealing caps and O rings Code No 055 0964 __ Buckets and sealing caps are optional _ Tube Rack Adaptor Code No Sealing caps and O rings Code No 055 0964 Buckets are equipped with rotor Sealing caps ar
12. the maximum speed in increments of 100 rpm e For the slow deceleration the natural deceleration without braking starting speed Nb can be set from the maximum speed to 0 in decrements of 100 rpm Maximum Speed Model 4000 6 000rpm Model 4200 16 000rpm Rapid deceleration Slow deceleration Slow acceleration Rapid acceleration Time High speed model 4200 Maximum Speed 16 000rpm Maximum RCF 23 470xg The Microtiter rotor accommodating 24 x 2 mL tubes is rated for 16 000 rpm 23 470 x g A high speed microtiter rotor can also be used The 4000 4200 models share these features A tool less rotor is employed for easy rotor tor changing Excluding the RA 2724M w No tools are required when setting or changing applicable rotors The Microtiter rotor RA 2724M can be operated at 16 000 rpm Model 4200 An automatic interlock lid is employed A tube rack Code No 055 0880 055 1140 has been The lid automatically opens when rotation stops developed to accommodate blood collecting tubes The lid can also be set to be opened by pressing the lid of various sizes such as 5 mL 7 mL 10 mL and 15 open key after rotation stops mL glass tubes simultaneously with the st 722M sT 2504Ms swinging bucket rotor Blood collecting tubes can be centrifuged using this tube rack Biohazard proof rotor that can be autoclaved There is a swinging bucket rotor that can be autoclaved a
13. ushion Maximum 16 tubes of 5 7 mL blood collecting tubes made by Termo Venoject II can be used 5 7mL blood collecting tubes made by SEKISUI Insepack II Termo Venoject II Nipro Neotube Beckton Dickinson Vacutenar can be used Tube for flow cytometry can also be used Vacutenar 8 mL blood collecting tubes for CPT cell separation nominal 16 x 125 made by Beckton Dickinson can be used 5 10mL blood collecting tubes made by SEKISUI Insepack II Termo Venoject II Nipro Neotube Beckton Dickinson Vacutenar can be used Tube for flow cytometry can also be used Sealing adaptors for biohazard proof for 50 mL conical tube Code No 055 5760 for 50 mL OakRidge tube Code No 055 4310 can be used With adaptors Code No 055 7400 and cushions Code No 024 1400 15mL glass tubes can be used With adaptors Code No 055 1280 15mL conical tubes can be used This is sealing bucket and it is equipped with sealing cap and O ring silicone 175 225 mL BD Falcon tubes Code No 352076 No 352075 require cushions Code No 352090 200 mL Nunc bottles Code No 376813 require cushions Code No 377585 Nalgene and Herolab 250mL flat bottom bottles can be used Various sputum tube capacities can be used Contact our distributor for details Verify plate strength before centrifuging Plates in lower position may fracture Optional tray is available Code No 055 6370 Nalgene plastic tube Code No 3110 0120 No 3117 0120 BD Falcon plastic tube C