1. ler LA EE Manual User Displays When the system is operating one of five displays may be shown Pressing NEXT will alternate between the displays shown below User 1 Typical user display Shows volume remaining to regeneration This screen will not be viewed if the control is set for time clock operation User 2 Displays number of days to next regeneration User 3 Flow Rate Displays present flow rate Not viewed along with SOFTENING or FILTERING Icon if ALT A or ALT b is set in CONFIGURATION 4 and the valve is currently in Standby When 1 0T is set in CONFIGURATION 1 the display will indicate the tank currently in Service A or b in the leftmost digit User 4 Displays total volume in gallons since last reset If a meter is not used this display will be shown but 0 will be displayed PRESS V FOR 3 SECONDS TO RESET TO 0 User 5 Shows current time Setting Time of Day Push NEXT until time of day screen is displayed Press and hold W until SET TIME is displayed and the hour flashes once Press A or V until the correct hour is displayed Then press NEXT The minutes will flash Press A or Y until the correct minute is displayed Press NEXT to return to the User Displays Time of day should only need to be set after power outages lasting more than 8 hours if the battery has been depleted and a power outage occurs or when daylight saving time begins or ends If a power outage lasting more than
2. REGEN N REGEN THI DUSS next wwe a BACKWASH next A vuuvrriey 2 bi RANEY next A REGEN gE 22 m T 2 REGEN gE n m T REGEN l n very jo BACKWASH next A Zz 4 vue SET Noe REGEN next A 4 Page 11 OEM Softener System Setup Step 1S Press NEXT and simultaneously for 5 seconds and release If screen in Step 2S does not appear the lock on valve programming has been activated To unlock press V NEXT amp REGEN in sequence then press NEXT and Y simultaneously for 5 seconds and release Step 2S Choose SOFTENING using A or V Press NEXT to go to Step 3S Press REGEN to exit OEM Softener System Setup Step 3S Choose Brining Direction using A or V This screen is not viewed when Step 2S is set to Filtering Press NEXT to go to Step 4S Press REGEN to return to previous step Step 4S Set Refill location using A or V e PoST to refill the brine tank after the final rinse or e PrE to refill the brine tank four hours before the regeneration time set This screen is not viewed when Step 2S is set to Filtering Press NEXT to go to Step 5S Press REGEN to return to previous
3. New Diagnostics Settings added Software Version Volume Since Last Regeneration Reserve Capacity 63 day Usage History Twin Tank Transfer History and MAV Drive History Form No V3435EE 1 14 2014 U S Patents 6 402 944 6 444 127 6 776 901
4. 8 hours occurs the time of day will flash on and off which indicates the time of day should be reset If a power outage lasts less than 8 hours and the time of day flashes on and off the time of day should be reset and the battery replaced EE Manual NEXT __ REGEN NEXT REGEN V SET wv next REGEN Step 3CS SET MaA m TITANS REGEN V Page 7 Configuration Settings Step 1CS Press NEXT and VY simultaneously for 5 seconds and release Press NEXT and Y simultaneously for 5 seconds and release If the screen in Step 2CS does not appear the lock on the valve is activated To unlock press V NEXT A and REGEN in sequence then press NEXT and YW simultaneously for 5 seconds and release Press NEXT and W simultaneously for 5 seconds and release Step 2CS Use A or Y to select 1 0 for 1 valve 1 25 for 1 25 valve 1 5 for 1 5 valve 2 0 for 2 valve or 1 0F for twin valve If 1 0 1 25 or 1 0T are selected press NEXT to go to Step 4CS If 1 5 or 2 0 are selected press NEXT to go to Step 3CS Press REGEN to exit Configuration Settings Vuvuvarrrreree FL PUL TETEL TTD NANNANAN V Step 3CS Use A or to select meter size Settings available are 1 5 SET 2 0 3 0 1 0r 1 0 Remote Meter or PUL Variable Meter Calibrat
5. have a delayed regeneration at the pre set time Page 10 Configuring the Control Valve for System Controller Operation Select SYS to link control valve to System Controller For communication between control valve and System Controller a three wire communication cable is required Selection requires that a connection to a Clack No Hard Water Bypass V3070FF or V3070FM be made to the two pin connector labeled MAV located on the printed circuit board for WS1 and WS1 25 control valves For valve types WS1 5 and WS2 a connection from a Clack No Hard Water Bypass V3097 BSPT or V3098 BSPT to the two pin connector labeled MAV located on the printed circuit board is required Press NEXT to go to Step 6CS Press REGEN to return to previous step SET LBS FILL NEXT REGEN FIAI EXIT TO DISPLAY SCREENS EE Manual SET vaar TITTTEL NANNAN NEXT REGEN IENE Step 6CS Fill Units If set as a softener if Step 2CS is set to 1 5 and FILL is part of the Regeneration Cycle Sequence FILL UNITS of MIN or LBS can be selected Press NEXT to exit OEM Configuration Setup Press REGEN to return to previous step SET FILL EE Manual next REGEN SET vir RARE next REGEN d 7 BRINE next A VVVVVANVN Dre REGEN gE S m
6. of regenerations that have occurred since startup Press the NEXT button to go to Step 6D Press REGEN to return to previous step Step 6D Error Log This display shows a history of the last 10 errors generated by the control during operation Press A or W to view each recorded error Press NEXT to go to Step 7D Press REGEN to return to previous step Step 7D Days since last regeneration This display shows the days since the last regeneration occurred Press NEXT to go to Step 8D Press REGEN to return to previous step Step 8D Volume since last regeneration This display shows the volume of water that has been treated since the last regeneration This display will equal zero when a water meter is not installed Press NEXT to go to Step 9D Press REGEN to return to previous step EE Manual TODAY H 0 laly 400 REGEN Page 19 Step 9D Volume reserve capacity used for last 7 days If the valve is set up as a softener a meter is installed and Set Volume Capacity is set to Auto this display shows day 0 for today and flashes the reserve capacity Pressing A will show day 1 which would be yesterday and flashes the reserve capacity used Pressing A again will show day 2 the day before yesterday and the reserve capacity Keep pressing A to show the capacity for days 3 4 5 and 6 W can be pressed to move backwards in the day series This display does n
7. REGEN Fe oct i NEXT next A REGEN rl GAL x1000 next A REGEN DAY o next A REGEN Li next A vee KAFEA ANNAN next A REGEN REGEN DAY next A REGEN oo GAL REGEN REGEN next A oo EE Manual Diagnostics Step 1D Press A and Y simultaneously for 5 seconds and release If screen in Step 2D does not appear the lock on the valve is activated To unlock press V NEXT A REGEN in sequence then press A and V simultaneously for 5 seconds and release Step 2D Software Version Press NEXT to go to Step 3D Press REGEN to exit Diagnostics Step 3D Volume total used since start up This display shows the total gallons treated since startup This display will equal zero if a water meter is not installed Press the NEXT button to go to Step 4D Press REGEN to return to previous step Step 4D Days total since start up This display shows the total days since startup Press the NEXT button to go to Step 5D Press REGEN to return to previous step Step 5D Regenerations total number since start up This display shows the total number
8. TA NEXT gE n m T BACKWASH NEXT AAZ SET RINSE next V REGEN Step 5F SET ANNE GAL REGEN next REGEN SET TIME REGEN NORMAL NEXT V REGEN Step 1F Press NEXT and YW simultaneously for 5 seconds and release If screen in Step 2CS does not appear the lock on the valve is activated To unlock press V NEXT A REGEN in sequence then press NEXT and Y simultaneously for 5 seconds and release Step 2F Choose FILTERING BACKWASH or FILTERING REGEN see table using A or V Press NEXT to go to Step 3F Press REGEN to exit OEM Filter System Setup SET FILTERING TETIT NANA Step 3F Select the time for the first cycle using A or V Press NEXT to go to Step 4F Press REGEN to return to previous step Step 4F Select the time for the second cycle using A or V If Step 2F is set to FILTERING REGEN press NEXT to program the rest of the cycle times If Step 2F is set to FILTERING BACKWASH press NEXT to go to Step 5F Press REGEN to return to previous step Step 5F Set Regeneration trigger using A or V If value is set to OFF regeneration will be triggered solely by the day override setting see Installer Display Settings Step 4 e a number regeneration will be triggered
9. V will close the B port and keep open the A port until the error is corrected and reset EE Manual Page 9 WS1 WS1 25 and WS1 5 Valves SET SEESI For Clack Corporation alternator systems using WS1 WS1 25 and WS1 5 valves there will be an option to delay the last two cycles of regeneration only Rinse and Fill This feature splits the regeneration into two portions The first portion of the regeneration will start immediately and all programmed cycles before the Rinse and Fill cycles will be performed After all programmed cycles before Rinse and Fill are NEXT A V REGEN completed the control valve will drive to the service position displaying Delayed Rinse Fill Pending When the volume of the on line unit is depleted to 10 of its programmed capacity the control valve will be triggered to finish the second portion of the regeneration and complete A i 5 SET SET T E T the Rinse and Fill cycles and return to Service and be placed into Standby mode and wait to come on line for service Set to oFF to d F L H y deactivate this feature FILL RINSE at EET PITTI TEETLT IE NNNNVANNAANA WS2 Valve SET Merc eee For Clack Corporation alternator systems using the WS2 valve when NEXT is pressed after selecting r ALT A or ALT B a display will allow the user to set the amount of pre service rinse time for the stand L by tank ju
10. Water Specialist EE Control Valve Programming and Cover Drawing Manual Page 2 EE Manual EE Manual Page 3 Table of Contents BE Front Cover and Drive ASsembly aiee ana e aae a a E E G A asad cyessssqutezatansantecstaese 4 Regeneration and Error Screens Button Operations and Functions sessssesessesssresterrssesrssrstssreesteertrsreresenrssreresrerestte 5 USET TIS DIAS ioaea EA TE A E E E AEI E es tipo st A A A E 6 Configuration SetUNo Sorra a E R O oeeadesces tee ceses T OEM Softener System SSD sena EE A AAEE AEA E EEE EEE 11 Settimo Options Tables pencu a E A a E A A E 14 OEM Filter System Setups sencon rasan E E a EA A a A a AAE S 15 Installer Display Settini s iosnosea aa oE E E E T E S 17 WIA PMOSPICS erona naa a E A A E N Ra TE 18 Page 4 EE Manual EE Front Cover and Drive Assembly Drawing No Order No Description Quantity 1 V3175EE 01 WS1EE FRONT COVER ASSEMBLY 1 2 V3107 01 WS1 MOTOR 1 3 V3106 01 WS1 DRIVE BRACKET amp SPRING CLIP 1 4 V3408EE O4BOARD WSITHRU 2 EE PCB 5 DIGIT REPL 1 5 V3110 WS1 DRIVE GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 Not Shown V3186 WS1 AC ADAPTER 120V 12V i V3186 01 WS1 AC ADAPTER CORD ONLY Not Shown V3178 WS1 Drive Back Plate 1 Refer to Control Valve Service Manual for other drawings and part numbers AC Adapter US Internation
11. al Setting Options Table Filters should only use shaded options Volume Regeneration Time Day Result Capacity Option Override Reserve capacity automatically estimated AUTO NORMAL oFF Regeneration occurs when volume capacity falls below the reserve capacity at the next Regen Set Time Reserve capacity automatically estimated AUTO NORMAL Any number Regeneration occurs at the next Regen Set Time when volume capacity falls below the reserve capacity or the specified number of days between regenerations is reached er Reserve capacity not automatically estimated Bae NORMAL oFF Regeneration occurs at the next Regen Set Time when volume capacity reaches 0 R FF FF Reserve capacity not automatically estimated Regeneration occurs at the next Regen Set Time when the specified number of days oFF NORMAL Any number between regenerations is reached Na Reserve capacity not automatically estimated y NORMAL Any number Regeneration occurs at the next Regen Set Time when volume number F capacity reaches 0 or the specified number of days between regenerations is reached o Reserve capacity NOT automatically estimated Regeneration occurs immediately when volume capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when volume capacity reaches 0 volume capacity reaches 0 Reserve capacity automatically estimated Regeneration occurs when volume capacity falls below the
12. al Relay Specifications 12V DC Relay with a coil resistance Supply Voltage 120 VAC 230V AC not less than 80 ohms If mounting relay under the cover check for proper mounting dimensions on the backplate Supply Frequency 60 Hz 50 Hz ET On OO Output Voltage 12 VAC 12 VAC Ee a Output Current 500 mA 500 mA PC Board Relay Terminal Block Relay RLY 1 Coil COM Coil When replacing the battery align positives and push down to fully seat Correct ION Battery replacement is 3 volt ele Battery gt lt lithium coin cell type 2032 g Th Orientation ne A p Battery Fully Seated e PC Board Relay a Terminal Block EE Manual TIME REGEN REMAINING MIN BACKWASH Page 5 Regeneration and Error Screens Regen Screen Displays the time remaining in the current cycle Pressing REGEN advances to the next cycle Error Pi Error Screen H F Jj Alternated flashing Err and error code every 3 seconds Clear by disconnecting the power supply at the PC board and reconnecting or press NEXT and REGEN Prd S bY REGEN Prd FILL RINSE NEXT REGEN REGEN simultaneously for 3 seconds In Alternator Systems when a unit is waiting to initiate the first cycle step of regeneration REGEN Pndg is displayed STbY is displayed in Alternator Systems when a valve is in Standby state REGEN Pndg RINSE FILL is displayed whenever a ze
13. by the value specified in gallons See Setting Options Table for more detail Press NEXT to go to Step 6F Press REGEN to return to previous step Step 6F Set Regeneration Time Options using A or V If value is set to e NORMAL means regeneration will occur at the preset time on 0 means regeneration will occur immediately when the volume capacity reaches 0 zero or e NORMAL on 0 means regeneration will occur at one of the following the preset time when the volume capacity falls below the reserve or the specified number of days between regenerations is reached whichever comes first or immediately after 10 minutes of no water usage when the volume capacity reaches 0 zero NORMAL is the default if Step 5CS is set to ALT A or ALT B and NORMAL on 0 is not available on 0 is the default if Step 2CS is set to 1 0T and NORMAL on 0 is not available This step will not appear if Step 5F is set to off or Step 5CS is set to SYS See Setting Options Table for more detail Press NEXT to go to Step 7F Press REGEN to return to previous step Page 16 EE Manual Step 7F Set Relay Operation using A or V The choices are SET riit e Set Time on Relay activates after a set time at the beginning of a foes regeneration and then deactivates after a set period of time The start of E E L H Y Z m T regeneration is defined as the first backwash cycle or Dn brine cycle whichever co
14. d to be used with the alternator or separate source functions nfiguring th ntrol Valve for No Har ter B ration SET NAANAANANA eee Select nHbP for control operation For no hard water bypass operation the three wire communication cable is not used rra Parit MEETS Selection requires that a connection to MAV or a Clack No Hard Water Bypass Valve is made to the two pin connector labeled MAV located on the printed circuit board If using a MAV the A port of the MAV must be plugged and the valve outlet connected to the B port When set to nHbP the MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NOTE If the control valve enters into an error state during regeneration mode the no hard water bypass valve will return to the open Position if not already there nfiguring th ntrol Valve for r r ration SET RENRERNERU SEIT E9727 Select SEPS for control operation For separate source operation the three wire communication cable is not used TIEEETLLLLNANNANNANN Selection requires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin connector labeled MAV located on the printed circuit board The C port of the MAV must be connected to the valve inlet and the A port connected to the separate source used during regeneration The B port must be connected to the fee
15. d water supply When set to SEPS the MAV will be driven closed before the first regeneration cycle and be driven open after the last regeneration cycle NOTE If the control valve enters into an error state during regeneration mode the MAV will return to the open position if not already there Selecting the Control Valve to act as an alternator 519 0 and higher Use 3 wire Interconnect Cables for all communication between units 518 3 and lower Use 2 wire Interconnect Cables for twin alternators with independent flow meters Prior to starting the programming steps connect the communication cable to each control valve board s three pin connector labeled COMM CABLE Also connect the meter cord to either control valve to the three pin connector labeled METER O ener Softener Valve Programming Steps Set to ALTA Connect the outlet plumbing of ALT A Set to ALT b valve to the MAV s A port and connect Connect the outlet plumbing of ALT b valve to the Configuration Settings SIEP OCS the MAV s two pin wire connector to the MAV s B port No electrical connections are required two pin connector labeled DRIVE on between the ALT b valve and the MAV the ALT A valve If set up for a filter in Step 5F set Volume Capacity in Gallons in Step 6F select Regeneration Time Option on 0 and in Step 3I select Day Override oFF NOTE If the control valve is in an error state during regeneration mode the MA
16. efill 2 0 or 1 5 set to MIN softening only 0 1 99 0 minutes 0 1 99 0 minutes Service 1 480 minutes NA If 1 5 or 2 0 is selected in Step 2CS cycles can be set to oFF The user can initiate manual regeneration The user has the option to request the manual regeneration at the delayed regeneration time or to have the regeneration occur immediately 1 Pressing and releasing the REGEN button REGEN TODAY will flash on the display and the regeneration will occur at the delayed regeneration time The user can cancel the request by pressing and releasing the REGEN button 2 Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control by pressing NEXT and REGEN simultaneously for 3 seconds Page 6 General Operation ER CAPACITY REMAINING SOFTENING hunan E GAL REGEN MORAY NEXT REGEN AV so REMAINING DAY NEXT REGEN Alv gE SOFTENING TIEA GAL MN B NEXT REGEN Alv gE m GAL x1000 NEXT REGEN ALV TIME mpa ILLI NEXT REGEN AV next A kA REGEN 8 TIME NEXT REGEN AV gE TIME
17. ent the number of hours ago that the transfer occurred The display alternates with the volume that was treated before the tank transferred Press NEXT at any time to go to Step 12D Press REGEN to return to previous step TIME TIME gt H n REGEN L t REGEN LI TODAY TODAY REGEN A V NEXT Press and hold A and W buttons for 3 seconds while in Step 12D to reset the MAV drive history in both the retracted and extended piston rod position To view the old MAV drive history data for retracted and extended rod position press and hold REGEN and A while in Step 12D Press NEXT to advance display to the old MAV drive history TIME a TIME SOFTENING mn FTENIN TODAY L Lj laly EXIT DIAGNOSTICS M Li Slaw A gt TODAY REGEN Step 12D MAV Drive History in the direction of retracted piston rod position Display will only be shown if 1 0T is selected in Step 2CS or OFF is not selected in Step 5CS Up to a four digit number will appear after the L which stands for latest and A which stands for average Drive time is measured in 1 100 of a second i e a 17 10 second move is displayed as 1710 Press NEXT at any time to go to Step 13D Press REGEN to return to previous step TIME REGEN TIME s Hiii SOFTENING H 125 Step 13D MAV Drive History in the direction of extended piston rod position Di
18. ion Variable meter pulses of 0 1 150 0 PPG can be selected SET veneer Press NEXT to go to Step 4CS Press REGEN to return to previous step GAL REGEN TITINYAN Step 4CS Selecting the use of an outside signal to initiate a regeneration Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located on the printed circuit board Following is an explanation of the options oFF feature not used NOTE In a twin alternating system each control must have a separate dP signal or dP switch One dP signal or one dP switch cannot be used for both controls on0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will be signaled to the unit In a twin alternating system the MAV will transition first to switch units so that the signaled unit can start regeneration After the MAV has fully transitioned the regeneration begins immediately Note For WS1 WS1 5 control valves programmed for twin alternating if the dP function on0 is set the Delayed Rinse and Fill feature is not available dEL If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the scheduled delayed regeneration time In a twin alternating system once the dP switch is triggered the PC Board will display REGEN TODAY and when the delayed regen time comes the control will switch tanks and the triggered unit will
19. mes first NEXT _ REGEN SET TIME Ce i MIN next _ REGEN Step 9F SET TIME vanan uu REMAINING ee PITETULLENNNNANNY A REGEN NEXT e Set Gallons Filtering on Relay activates after a set number of gallons have been used while in service and then deactivates after a set period of time or after the meter stops registering flow whichever comes first e Set Gallons Filtering Regen on Relay activates after a set number of gallons have been used while in service or during regeneration and then deactivates after a set period of time or after the meter stops registering flow whichever comes first eERROR Relay closes whenever the valve enters error mode and immediately deactivates when error mode is exited If set to ERROR Steps 8F and 9F will not be shown e Set Off If set to Off Steps 8F and 9F will not be shown Press NEXT to go to Step 8F Press REGEN to return to previous step Step 8F Set Relay Actuation Time or Gallons using A or V The choices are e Relay Actuation Time After the start of a regeneration the amount of time that should pass prior to activating the relay The start of regeneration is defined as the first backwash cycle or brine cycle whichever comes first Ranges from 1 second to 200 minutes e Relay Actuation Gallons Relay activates after a set number of gallon
20. o to step 31 Press REGEN to exit Installer Display Settings Step 3I Day Override When volume capacity is set to oFF sets the number of days between regenerations When volume capacity is set to AUTO or to a volume sets the maximum number of days between regenerations If value set to oFF regeneration initiation is triggered solely by volume used If value is set in days allowable range from 1 to 28 regeneration initiation will be called for on that day regardless of actual water usage Set Day Override using A or V e number of days between regeneration 1 to 28 or OFP See Setting Options Table for more detail on setup Press NEXT to go to step 41 Press REGEN to return to previous step Step 4I Next Regeneration Time hour Set the hour of day for regeneration using A or V The default time is 2 00 This display will show REGEN on 0 GAL if on 0 is selected in Set Regeneration Time Option in OEM Softener System Setup or OEM Filter System Setup Press NEXT to go to step 5I Press REGEN to return to previous step Step 5I Next Regeneration Time minutes Set the minutes of day for regeneration using A or V This display will not be shown if on 0 is selected in Set Regeneration Time Option in OEM Softener System Setup or OEM Filter System Setup Press NEXT to exit Installer Display Settings Press REGEN to return to previous step EXIT INSTALLER DISPLAY SETTINGS Page 18 A V
21. ot appear if 1 01 is set in Step 2CS if ALT A or ALT B are selected in Step 5CS or anytime the reserve capacity is not determined by the control Press NEXT at any time to go to Step 10D Press REGEN to return to previous step Step 10D Volume 63 day usage history This display shows day 0 for today and flashes the volume of water treated today Pressing A will show day 1 which would be yesterday and flashes the volume of water treated on that day Continue to press A to show the maximum volume of water treated for the last 63 days If a regeneration occurred on the day the word REGEN will also be displayed This display will Press NEXT at any time to go to Step 11D Press REGEN to return to previous step Step 11D Twin Tank Valve transfer history only displays when 1 0T was selected in Step 2CS Use A or to scroll through the last i g TODAY gt A V REGEN show dashes if a water meter is not installed Step 11D TIME wee TENN A 3 REGEN 7 gt i rl Li NEXT 10 tank transfers The first position in the display ranges from 0 to 9 with the lowest number being the most recent transfer The second position in the display will be either A or b If A then the tank with the valve on it was in service if b the tank with the in out head on it was in service The next three digits repres
22. reserve capacity at the next no An number AUT NORMAL on 0 ug 9 2 Regen Set Time or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve capacity automatically estimated Regeneration occurs at the next Regen Set Time when volume capacity falls below the AUTO NORMALon0 Any number SS ina gens pact reserve Capacity or the specified number of days between regenerations is reached or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve capacity not automatically estimated An Regeneration occurs at the next Regen Set Time when the specified number of days y NORMAL on 0 Any number 8 alee s P y number between regenerations is reached or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve capacity NOT automatically estimated oFF Regeneration occurs immediately when volume capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when Reserve Capacity estimate is based on history of water usage Reserve Capacity estimate is not available with alternator systems or Twin Tank Valve EE Manual NEXT Page 15 OEM Filter System Setup Cycle Sequence Adjustable Default Times minutes Filtering Backwash 8 o o Cycle is non adjustable not shown in cycle sequence programming ETREZE FILTERING MIET
23. ro capacity tank has transferred to an off line state and is currently waiting to initiate the second portion of a regeneration cycle Viewed only when Delayed Rinse and Fill is set to ON Button Operation and Function Scrolls to the next display Pressing once and releasing will schedule a regeneration at the preset delayed regeneration time Pressing again and releasing will cancel the regeneration Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle Pressing in the program levels will go backwards to the previous screen NEXT REGEN NEXT REGEN V Changes variable being displayed Key sequence to lock and unlock program settings Holding for 3 seconds initiates a control reset The software version is displayed and the piston returns to the home service position resynchronizing the valve Used with valve type 1 0T holding for at least 3 seconds causes a switch in the tank in Service without cycling REGEN A the regeneration valve After tank switch days remaining and capacity remaining status is retained for each tank until the next regeneration Regeneration Cycles and Times Backwash 1 120 minutes 1 120 minutes Regenerant Draw Slow Rinse UP or DN 1 180 minutes 1 180 minutes Fast Rinse Regenerant Refill 1 120 minutes 1 120 minutes 0 1 200 0 Ibs 1 99 0 GAL Regenerant R
24. s NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Set System Capacity using A or V The System Capacity setting should be based on the volume of resin and LBS of salt fill set in Step 9S Press NEXT to go to Step 11S Press REGEN to return to previous step Step 11S Set Volume Capacity using A or V If value is set to e AUTO capacity will be automatically calculated and reserve capacity will be automatically estimated e OFF regeneration will be triggered solely by the day override setting see Installer Display Settings Step 41 e a number regeneration will be triggered by the value specified in Gallons If oFF or a volume is used the hardness display will not be allowed to be set in Installer Display Settings Step 2I See Setting Options Table for more detail Press NEXT to go to Step 12S Press REGEN to return to previous step Step 12S Set Regeneration Time Options using A or VW If value is set to e NORMAL means regeneration will occur at the preset time e on 0 means regeneration will occur immediately when the volume capacity reaches 0 zero or e NORMAL on 0 means regeneration will occur at one of the following the preset time when the volume capacity falls below the reserve or the specified number of days between regenerations is reached whichever comes first or immediately after 10 minutes of no water usage when the volume capacity reaches 0
25. s has passed through the meter Ranges from 1 to 200 gallons Press NEXT to go to Step 9F Press REGEN to return to previous step Step 9F Set Relay Deactivate Time using A or V e If Set Time on is selected in Step 7F the relay will deactivate after the time set has expired Ranges from 1 second to 200 minutes e If Set Gallons Filtering on or Set Gallons Filtering Regen on is selected in Step 7F the relay will deactivate after the time set has expired or after the meter stops registering flow whichever comes first Ranges from 1 second to 20 minutes Press NEXT to exit OEM Filter System Setup Press REGEN to return to previous step EXIT OEM FILTER SYSTEM SETUP EE Manual NEXT V REGEN SET HARDNESS vues TITEL NNNNA A REGEN NEXT SET REGEN DAY TITTENNAN NEXT SET TIME Wee AN REGEN Af Lj a V REGEN SET TIME PE REGEN cl A V REGEN NEXT Page 17 Installer Display Settings Step 1I To enter Installer Display press NEXT and A simultaneously for about 5 seconds and release Step 2I Hardness Set the amount of influent hardness using A or V This display will not be viewed if FILTERING BACKWASH or FILTERING REGEN is selected in Step 2F or if oFF or a number was selected in Step 11S Press NEXT to g
26. splay will only be shown if 1 0T is selected in Step 2CS or OFF is not selected in Step 4CS Up to a four digit number will appear after the L which stands for latest and A which stands for average Drive time is measured in 1 100 of a second i e a 17 15 second move is displayed as 1715 Press and hold A and W for 3 4 q d CI Co SOFTENING pq L I 4 seconds while in Step 13D to reset the MAV drive history in both the extended and retracted piston rod position To view the old MAV drive history data see Step 12D Press NEXT at any time exit Diagnostics Press REGEN to return to previous step Page 20 EE Manual Revision History 12 7 2012 PAGE 5 Added Used with valve type 1 0T 1 14 2014 NOTE All screen displays have been changed due to the larger LCD display PAGE 4 V3175EE 01 WS1EE FRONT COVER ASSEMBLY V3408EE 04BOARD WS1THRU2 EE PCB 5 DIGIT REPL new board and cover drawings added relay information PAGE 5 Regeneration cycle times have been updated PAGE 7 Programming steps have all been updated to reflect the enhancements Added Step 3CS PAGE 10 Added Step 6CS PAGE 11 Added Softener System Setup PAGE 12 Step 13S Relay Operation setup PAGE 14 Added Setting Options Table PAGE 15 Added OEM Filter System Setup PAGE 16 Step 7F Relay Operation setup PAGE 17 New Installer Display Settings PAGE 18
27. st prior to returning to service Set to oFF to deactivate this feature With 1 0T set the same TEE EEETE IEAA NNNNANANNAANA display appears and is set in a similar manner NEXT A V REGEN SET ww Pr E 3 w RINSE A V ReceN in fn Retracted Extended Valve A in Service Position Valve B in Service Position MAV piston rod Retracted MAV piston rod Extended Note Clack Twin Alternator Operations e Twin alternating systems can be programmed with a day override setting combined with the normal volume based regeneration programming A twin alternating system in this configuration will then regenerate based on the volume used or the day override if there is a period of low water usage e Twin alternating systems can be programmed as a time clock only based regenerating system In this configuration the days remaining are counted only on the unit that is in service The unit in Stand by Mode only notes days in diagnostics which results in time clock only twin regeneration initiation e Twin alternating systems can be programmed for a delayed regeneration time The system will allow an immediate transfer of the MAV to switch tanks and place a fully regenerated unit in service once a unit becomes exhausted The exhausted unit will then be placed into Stand by Mode and allowed to
28. step Step 5S Select the time for the first cycle using A or V For valve types 1 5 and 2 0 oFF is also available Press NEXT to go to Step 6S Press REGEN to return to previous step Step 6S Select the time for the second cycle using A or V For valve types 1 5 and 2 0 oFF is also available NOTE The display will flash between cycle number and time and brine direction UP or dn Press NEXT to go to Step 7S Press REGEN to return to previous step Step 7S Select the time for the third cycle using A or V For valve types 1 5 and 2 0 oFF is also available Press NEXT to go to Step 8S Press REGEN to return to previous step Step 8S Select the time for the fourth cycle using A or V For valve types 1 5 and 2 0 oFF is also available Press NEXT to go to Step 9S Press REGEN to return to previous step Page 1 2 SET BS ey at next V REGEN Step 10S SET CAPACITY 11171 FR atom x1000 next AV REGEN Step 11S SET AIRNRRRSOSEEFITTT GAL REGEN next V REGEN Step 12S SET TIME REGEN NORMAL NEXT REGEN EE Manual Step 9S Select the pounds for the fifth cycle using A or V For valve types 1 5 and 2 0 oFF is also available NOTE if Step 2CS is set to 2 0 or Step 7CS is set to MIN Fill will be in minutes Pres
29. then go into regeneration Note For WS1 WS1 5 control valves programmed for twin alternating if the dP function dEL is set the Delayed Rinse and Fill feature is not available HoLd If the dP switch is closed a regeneration will be prevented from occurring while there is switch closure In a twin alternating system the regeneration of a unit can be prevented upon switch closure If the unit depletes the capacity down to zero it will not be allowed to switch tanks to regenerate until the switch is open Note For WS1 WS1 5 control valves programmed for twin alternating the Delayed Rinse and Fill feature can be set Press NEXT to go to Step 5CS Press REGEN to return to previous step Page 8 EE Manual SET SET enn Step 5CS This display will not appear if 1 0 was selected in Step J a 2CS Allows selection of one of the following using A or V te gt O e the Control Valve to have no hard water bypass NEXT A V REGEN NEXT IN V REGEN e the Control Valve to have a separate source during the regeneration e the Control Valve to act as an alternator cycle or e the Control Valve to operate with the System Controller Select OFF when none of these features are used Only use Clack No Hard Water Bypass Valves or Clack Motorized Alternating Valves MAV with these selections Clack No Hard Water Bypass Valves 1 or 1 25 V3070FF or V3070FM are not designe
30. to Off Steps 14S and 15S will not be shown Press NEXT to go to Step 14S Press REGEN to return to previous step EE Manual SENINE a Oo ue next _ REGEN SET TIME vau REMAINING MIN PITTTELTINNNNANNY REGEN ber LATV Page 13 Step 14S Set Relay Actuation Time or Gallons using A or V The choices are e Relay Actuation Time After the start of a regeneration the amount of time that should pass prior to activating the relay The start of regeneration is defined as the first backwash cycle Dn brine cycle or UP brine cycle whichever comes first Ranges from 1 second to 200 minutes e Relay Actuation Gallons Relay activates after a set number of gallons has passed through the meter Ranges from 1 to 200 gallons Press NEXT to go to Step 15S Press REGEN to return to previous step Step 15S Set Relay Deactivate Time using A or V e If Set Time on is selected in Step 13S the relay will deactivate after the time set has expired Ranges from 1 second to 200 minutes e If Set Gallons Softening on or Set Gallons Softening Regen on is selected in Step 13S the relay will deactivate after the time set has expired or after the meter stops registering flow whichever comes first Ranges from 1 second to 20 minutes Press NEXT to exit OEM Softener System Setup Press REGEN to return to previous step EXIT OEM SOFTENER SYSTEM SETUP Page 14 EE Manu
31. zero NORMAL is the default if Step 5CS is set to ALT A or ALT B and NORMAL on 0 is not available on 0 is the default if Step 2CS is set to 1 01 and NORMAL on 0 is not available This step will not appear if Step 11S is set to oFF or Step 5CS is set to SYS See Setting Options Table for more detail Press NEXT to go to Step 13S Press REGEN to return to previous step Step 13S Set Relay Operation using A or V The choices are SET rELAY e Set Time on Relay activates after a set time at the beginning of a regeneration and then deactivates after a set period of time The start of regeneration is defined as the first backwash cycle or Dn brine cycle whichever comes first SET TIME NEXT REGEN AV an e Set Gallons Softening on Relay activates after a set number of gallons have been used while in service and then deactivates after a set period of time or after the meter stops registering flow whichever comes first e Set Gallons Softening Regen on Relay activates after a set number of gallons have been used while in service or during regeneration and then deactivates after a set period of time or after the meter stops registering flow whichever comes first ERROR Relay closes whenever the valve enters error mode and immediately deactivates when error mode is exited If set to ERROR Steps 14S and 15S will not be shown e Set Off If set
Download Pdf Manuals
Related Search
Related Contents
Zerodraft Foam Sealant Instructions NEC MultiSync LCD1980SX (Black) Cornelius Agitator Gear Motor Capacitor ED/DF User's Manual designimplementa00ande - Calhoun: The NPS CN112S-1*00-*T00 Friedrich Albert Fallou (1794-1877) et sa « Pédologie » DP-C-Serie, Funktionsparameter - INSTR20381099 Installation ManualAPUV2,4,5,.8.qxd CERA HIDROFUGANTE American Standard Williamsburg Kitchen Faucets 4751 Series User's Manual Copyright © All rights reserved.