Viewstation OR Service Manual

image

Contents

1. PA 117 7793 10 11 AM 2006 09 29 FIGURE 6 5 Example Normal Monitoring Mode 19 Verify that patient data from a specific Spectrum OR can be displayed through the Viewstation OR With the Spectrum OR in normal monitoring mode and properly connected to the Viewstation OR network proceed as follows a From the Viewstation OR menu bar select the System Setup button b Select the Equipment Setup tab From the Equipment Setup tab disconnect any active equipment by selecting the Disconnect button c Select the Connect button The Device ID dialog box opens listing all Spectrum OR bedside monitors available on the network d Select the desired Spectrum OR to be connected e Select the Done button The Spectrum OR data should now be displayed on the Viewstation OR Viewstation OR Service Manual 0070 10 0665 6 7 Installing Viewstation OR Software Appendix A This page intentionally left blank 6 8 0070 10 0665 Viewstation ORTM Service Manual zx Appendix B 7 1 CMOS Setup Verification sessssececsssseseossssesecsossssecososssssesossssee 7 2 7 2 Independent Display Functional Requirements 7 7 Viewstation OR Service Manual 0070 10 0665 CMOS Setup Verification Appendix B 7 1 7 1 1 CMOS Setup Verification Verify that the VGA and serial cables are connected between the display s and the CPU Connect the keyboard and mouse touch pad to the CPU Power ON the Viewsta
2. Introduction This section of the service manual initially provides a high level overview of the Viewstation OR network followed by more detailed information Overview The Viewstation OR network is a comprehensive patient care monitoring system designed for use in a hospital setting The system is intended to be installed and used in a fixed non portable permanent location that serves as a secondary viewing station The Viewstation OR network consists of the following modules e Viewstation OR CPU Spectrum OR Bedside Monitor Independent Display Proprietary Ethernet Network Hardware and software components within each module provide system wide functionality and connectivity The monitoring capacity of the system is one Spectrum OR that is connected to the Viewstation OR CPU through the Ethernet network This service manual focuses on the Viewstation OR and Ethernet modules The Viewstation OR is a combination of both hardware e g CPU and display and software components i e Viewstation OR software application Core Functions The Viewstation OR is capable of displaying the following digital physiological parameters as monitored by the Spectrum OR 1 Heart Rate BPM 2 SpOz SAT 3 4 Invasive Blood Pressures SYS DIA Mean 4 Non Invasive Blood Pressure SYS DIA Mean 5 Two Temperatures 6 Respiration Rate RR 7 Inspired Expired CO 8 CO 9 CI 10 CCO 11 CCI 12 SvO 13 PAWP 0070
3. Verify the power LED on the display is ON This is usually located on the front panel On LCDs turn OFF the power switch and turn it back on Verify the logo is briefly displayed If the No Signal message is displayed on the screen no video signals are reaching the display Verify that the cable between the display and the CPU is making a good connection that the connector screws are tight and pins on the connectors are straight If the problem persists it is likely due to a problem within the CPU Verify that AC power switch is ON at the Viewstation OR CPU Reboot the Viewstation OR CPU Verify that the power and hard drive LEDs are illuminated and the fans are operating e If the display still does not come ON the problem is likely within the CPU e If the hard drive LED does not illuminate the problem is likely related to the CPU or the motherboard e If the fans are not operating the problem is likely the power supply Viewstation ORT Service Manual 0070 10 0665 2 3 Troubleshooting Repair Information The display comes ON but the Viewstation OR CPU does not complete self test Note the point at which the self test stopped e g passed through the memory check CMOS check Drive check Depending on where it stopped this may mean replacement of the motherboard memory chip or the hard drive is necessary The unit went through self test but did not get to the Viewstation OR operating screen It stays at
4. Pull the system hard drive rack out through the front of the chassis 2 5 7 Floppy Drive and Disclosure Hard Drive s Removal 1 Remove the four 4 screws securing the 3 5 inch floppy drive to the drive rack 2 Remove the cable retainer bracket from the floppy drive 3 Loosen the screws securing the cable retainer bracket to the floppy drive Remove the cable retainer bracket 4 Disconnect the power connectors and ribbon cables from the drive s 5 Remove the floppy drive from the drive rack 2 6 0070 10 0665 Viewstation ORTM Service Manual Repair Information Disassembly Instructions 2 5 8 CD ROM Drive Removal 1 Remove the two 2 screws securing the drive to the chassis 2 Press on the locking lever and pull the drive out of the chassis 2 5 9 Motherboard Removal 1 Remove the ATX power supply connector from J10 on the motherboard 2 Remove the ATX 12 V power connector from J12 on the motherboard 3 Disconnect the 40 pin ribbon cable from the CD ROM drive to the IDE2 connector 4 Disconnect the 40 pin ribbon cable from the hard drives to the IDE1 connector 5 Disconnect the 34 pin ribbon cable from the Floppy drive to the FDD1 connector 6 Disconnect the ribbon cable from PO serial port to J15 on the motherboard 7 Disconnect the ribbon cable from P1 serial port to J16 on the motherboard 8 Disconnect the ribbon cable from the unmarked serial port to J11 on the motherboard 9 Disconnect the speaker connector
5. Display Functional Reouirement eme eem 7 7 Electrical Requirements usi tere Y ETE RE DURER AE URSUS URS ER tana EORUM RR ERA 7 7 Power Supply irit petu EROR D ep E ES 7 7 Display Resolutions sirin etie ido de eg OE PRESS 7 7 Display Aspect Ratio iit icc ete de aee enne e ed re ERR eee o dodo sons conan La ek o nnda 7 7 Color Suppo GE 7 7 Image Brightness 7 7 Image Conlrdst as ete e det eege E 7 7 Viewing Angle M E 7 7 Mechanical R quirem nts sim 5 rro eR PAERUR EE ON AS VURASEUR EELER 7 8 ii 0070 10 0665 Viewstation ORTM Service Manual Table of Contents Connectors Cable Termination at the Viewstation OR PC 7 8 Mounting escitas HERE qr chy PO Eee ERR o eo EE EXE MEER EE rence 7 8 Environmental and Agency Reouirements emen enne nennen ree nere 7 8 Compliance e eed 7 8 Viewstation OR Service Manual 0070 10 0665 iii Table of Contents This page intentionally left blank iv 0070 10 0665 Viewstation ORTM Service Manual Foreword Introduction Foreword The Viewstation OR Service Manual is a guide for technically qualified personnel who perform maintenance and or repair on the Viewstation OR and its Ethernet network This manual conveys system wide information that is divided into sections For quick reference each chapter s title page displays a table of contents that indicates sectionally the topics covered This publication
6. and the receiver is located with the independent display Data signals are carried by CAT5 Ethernet cable and link the Viewstation OR CPU with the display s NOTE Both the transmitter and the receiver require a 110 VAC connection Viewstation OR Service Manual 0070 10 0665 1 5 System Modules Components and Peripherals Instrument Description The extenders can be separated by a maximum of 400 ft 122 m cable distance with a screen resolution of 1280 x 1024 1 3 3 Network Switches e An Ethernet switch is used if there are multiple Spectrum ORs on the network or if there is more than one Viewstation OR CPU connected to the Spectrum OR e The switch routes data from the Spectrum OR to all Viewstation OR CPUs on the network e The switch can be the Panorama E LAN switch or an independent switch dedicated to the Viewstation OR network 1 3 4 Mouse Touch Pad e The mouse touch pad enables changes to be made on the Independent Display e The mouse touch pad is connected to the KVM receiver via the PS2 mouse connector 1 3 5 Displays 1 3 5 1 Supplied ELO Compatible Touch Screen Display e A Surface Acoustical Wave SAW touch screen is supported as the standard input device on the 19 display The touch screen operates independent of a mouse or touch pad interface The actual touch screen and its controller are integrated into the display The touch screen communication is accepted by Viewstation OR via a serial por
7. bear at least one of these marks EMI EMC If the customer chooses a display that only meets the ITE requirements of Council Directive 89 336 EEC for electromagnetic emissions EN 55022 EN 61000 3 2 EN 61000 3 3 and immunity EN 55024 then the display when connected to the Viewstation OR PC may experience degraded performance due to its lower non MDD compliant electromagnetic immunity 0070 10 0665 Viewstation OR Service Manual Appendix B Independent Display Functional Requirements This page intentionally left blank Viewstation ORT Service Manual 0070 10 0665 7 9 0070 10 0665 Rev C July 17 2010 Mindray DS USA Inc e 800 MacArthur Boulevard e Mahwah NJ 07430 e USA e Dom Customer Service 1 800 288 2121 e Intl Customer Service 1 201 995 8000 e Dom Fax 1 800 926 4275 e Intl Fax 1 201 995 8680 e www mindray com Mindray Medical Netherlands B V e PO Box 26 e 3870 CA Hoevelaken e The Netherlands e Tel 31 33 25 44 911 e Fax 31 33 25 37 621 Mindray UK Limited e 3 Percy Road e St John s Park e Huntingdon e Cambridgeshire PE29 6SZ e United Kingdom Tel 01480 416840 Fax 01480 436588 Mindray Medical France SARL e Europarc Cr teil 123 Chemin des Bassins e 94035 Cr teil Cedex France Tel 0 1 45 13 91 50 e Fax 0 1 45 13 91 51 Mindray Medical German GmbH e Zwischen den B chen 4 e 64625 Bensheim e Germany Tel 49 6251 17524 0 e Fax 49 6251 17524 20 Mindray Medical International Ltd
8. e 2813 Office Tower Convention Plaza e No 1 Harbour Road e Wanchai e Hong Kong e Tel 852 2793 5596 e Fax 4852 2344 8824 0002 08 8918
9. may have been updated to reflect product design changes and or manual improvements NOTE Unauthorized servicing may void the remainder of the warranty Check with the factory or with a local authorized Service Representative to determine the warranty status of a particular instrument Warnings Precautions and Notes Please read and adhere to all warnings precautions and notes listed here and in the appropriate areas throughout this manual A WARNING is provided to alert the user to potential serious outcomes death injury or serious adverse events to the patient or the user A CAUTION is provided to alert the user signaling that special care is necessary for the safe and effective use of the device They may include actions to be taken to avoid effects on patients or users that may not be potentially life threatening or result in serious injury but about which you should be aware A NOTE is provided when additional general information is applicable Viewstation ORTM Service Manual 0070 10 0665 v Introduction vi Warnings Warnings WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING Do not attempt to use the Viewstation OR including cabling for any purpose other than its intended use Route cables neatly Ensure cables are not in the way of patient or hospital personnel Loading any unauthorized software including utilities on the V
10. retainer brackets CD ROM Drive and System Hard Drive 1 Install the replacement drive into the chassis 0070 10 0665 Viewstation ORTM Service Manual Repair Information 2 6 6 2 6 7 2 6 8 2 6 9 Re assembly Instructions 2 Connect the power and ribbon cables to the rear of the drive 3 Secure the drive to the chassis with the four 4 screws two on either side Auxiliary Fan 1 Connect the DC power connector to the fan 2 Verify that the label on the fan is facing the rear of the chassis which indicates the airflow is blowing out 3 Secure the fan to the rear chassis with the four 4 screws CMOS Battery Replacement Locate and remove the existing battery from the motherboard and replace it with a new CR 2032 battery 3V The positive terminal should be visible After battery replacement verify set up the CMOS per the CMOS Setup Verification information on page 7 2 Closing the Unit 1 Install the top and secure it with four 4 screws Rebooting and Testing the System 1 Reconnect the cables to the Viewstation OR CPU 2 Power ON the CPU and the display 3 If the system hard drive has been replaced the operating software must be reloaded Use the instructions included with the system software CDs to load the software and configure the system If the instructions are not available contact your local Service Representative or Technical Support Department Viewstation ORT Service Manual 0
11. the Parts List Ordering Information NOTE Mindray DS USA Inc maintains a policy of continuous development of product improvement and reserves the right to change materials specifications and prices without notice The following table lists the parts and part numbers associated with the Viewstation OR CPU DESCRIPTION Power Supply ATX PART NUMBER 0014 00 0075 01 AGP Display Board Motherboard Pentium 4 067 1 00 0220 02 067 1 00 0052 01 CD RW 0992 00 0178 01 System Hard Drive 0992 00 0084 07 Floppy Disk Drive 0992 00 0121 CMOS Battery 0146 00 0078 Auxiliary Fan CPU Case Only Cable IDE Drive 0119 00 02 14 03 0012 00 1546 01 Cable Floppy Drive 0012 00 1354 AC Power Cord 110V Domestic 0012 25 0001 Keyboard PS 2 0992 00 0108 Mouse PS 2 0992 00 0233 01 Patch Cable 10 CAT 5E crossover Patch Cable 6 straight pinned 0012 00 1392 05 0012 00 1274 01 Patch Cable 1 straight pinned 0012 00 1274 04 Patch Cable 2 straight pinned 0012 00 1274 05 Patch Cable 3 straight pinned 0012 00 1274 06 Patch Cable 10 straight pinned 0012 00 1274 07 ESD Protector Adapter 0137 00 0001 01 Touch Pad 0992 00 0238 01 Ethernet Switch 5 port 0992 00 0248 01 Ethernet Switch 8 port 0992 00 0248 02 0070 10 0665 Ordering Information Parts Replacement This page intentionally left blank 3 4 0070 10 0665 Viewstation ORTM S
12. the Viewstation OR CPU and the Spectrum OR are secure Verify that the LEDs on the network port of the Viewstation OR CPU are illuminated as follows left hand LED continuously ON right hand LED flashing 2 If the connection between the Spectrum OR and the Viewstation OR CPU is a direct connection via a crossover Ethernet cable verify that the cable connection is secure 3 If the connection between the Viewstation OR CPU and the Spectrum OR uses an Ethernet switch Verify that the cable connections between the Ethernet switch and the Viewstation OR CPU are secure Verify that the cable connections between the Ethernet switch and the Spectrum OR are secure Power cycle the Ethernet switch e Verify that the Power LED on the Ethernet switch is illuminated Each port on the Ethernet switch has a corresponding Port Status light that indicates that the cable connection has been established For each cable that is connected to the Ethernet switch verify that the corresponding Port Status light is illuminated If the Port Status light is not illuminated plug the cable into an available port and verify that the Port Status light for this new port is illuminated 4 Verify that the LEDs on the Comm Port of the Spectrum OR are illuminated as follows Yellow LED continuously ON Green LED flashing If either LED is not illuminated it may indicate that the Comm Port is defective Viewstation ORT Service Manual 007
13. the blue screen no desktop icons Clear the error and event logs contact a Service Representative for instructions and save the config tool The mouse touch pad does not function l Verify that the connections at the rear of the Viewstation OR CPU are secure and that they are in the appropriate locations 2 Check connections to the KVM Extender Transmitter amp Receiver 3 Repower the KVM Extender by disconnecting AC power from the transmitter and receiver 4 Reboot the system Is the mouse functional e f not install a new PS2 touch pad mouse and reboot the system again 5 Is the touch pad mouse functional now f not this may mean replacement of the Mother PCB No touch screen response only on supplied touch screen displays 1 Verify that the connections at the rear of the CPU are secure and that they are in the appropriate locations 2 Check connections to the KVM Extender Transmitter amp Receiver 3 Power cycle the KVM Extender by disconnecting AC power from the transmitter and receiver and then reconnecting the AC power 4 Clean the touch screen panel 5 Reboot the system Is the touch screen functional f not this may mean replacement of the touch screen display or the touch screen controller card 0070 10 0665 Viewstation ORTM Service Manual Repair Information Troubleshooting Network Communication Loss From a Spectrum OR Monitor 1 Verify that the Ethernet connections between
14. to pins 1 4 red to pin 1 on J20 10 Disconnect the green LED connector to pins 11 13 green to pin 11 on J20 11 Disconnect the power switch connector to pins 7 and 17 blue to pin 7 on J20 12 Disconnect the reset switch connector to pins 9 and 19 red to pin 9 on J20 13 Disconnect the red LED connector to pins 10 and 20 black to pin 10 on J20 14 Remove the 10 screws that secure the motherboard to the chassis 15 Remove the six Standoffs and washers from the back of the CPU 2 each on the unused serial port the parallel port and the unused VGA port 16 Remove the motherboard from the chassis Viewstation ORT Service Manual 0070 10 0665 2 7 Re assembly Instructions 2 6 2 6 1 2 6 2 2 6 3 2 6 4 2 6 5 Repair Information Re assembly Instructions This section provides information to assist the technician in re assembling components of the Viewstation OR CPU See FIGURE 1 3 for reference Motherboard Assembly 1 Secure the motherboard to the chassis using 10 screws 2 Attach the six Standoffs and washers on the back of the CPU 2 each on the unused serial port the parallel port and the unused VGA port 3 Connect the ATX power supply connector to J10 on the motherboard 4 If present connect the ATX 12 V power connector to J12 on the motherboard 5 Connect the 40 pin ribbon cable from the CDROM drive to the IDE2 connector 6 Connect the 40 pin ribbon cable from the hard drives to the IDE co
15. 0 10 0665 2 5 Disassembly Instructions Repair Information 2 5 Disassembly Instructions This section provides information to assist the technician in disassembly and removal of individual components for replacement The displays and network switches do not contain any user replaceable parts and are serviced on an exchange or replacement basis WARNING Disconnect AC power prior to any disassembly 2 5 1 Cover Removal 1 Remove the two 2 screws on the rear of the chassis 2 Slide the cover toward the rear and lift off 2 5 2 Front Panel Removal Grab the panel in the opening at the bottom and lift up and away from the chassis 2 5 3 Power Supply Removal 1 Disconnect the ATX power connector and the 12V power connector from the motherboard 2 Disconnect the power connectors from the floppy drive CD ROM drive system hard drive and disclosure hard drives 3 Remove the four 4 screws securing the power supply to the rear of the chassis 2 5 4 AGP Video Board Removal 1 Remove the screw securing the board to the chassis 2 Lift the board out of the AGP slot 2 5 5 Auxiliary Fan Removal 1 Disconnect the DC power connector from the motherboard 2 Remove the four 4 screws securing the fan to the rear of the chassis 2 5 6 System Hard Drive Removal 1 Remove the four 4 screws 1 internal 3 external securing the hard drive rack 2 Disconnect the power connectors and ribbon cables from the drive s 3
16. 070 10 0665 2 9 Re assembly Instructions Repair Information This page intentionally left blank 2 10 0070 10 0665 Viewstation OR Service Manual z0 Parts Replacement 3 1 Introduction eee e eee e eee eee eee eee e eene eee sense se sese se ssesssseeeeeeesssss sees 3 2 3 2 Available Replacement Parts and Assemblies 9 2 3 3 Product Variations Lecce ee eee eee eee eene esee esee ees sosse e eeesessss sees 3 2 3 4 Exchange Program eee ee eese eese eese sesso sesssesessseceesssesessss 3 2 3 5 Parts Pricing Information ccce esee eee ee eee ee neos ossoeeesssesessss 3 2 3 6 Ordering Information e eee ecce ee eee ee eee eee eese sesso seeeesssssse eee 3 3 Viewstation ORT Service Manual 0070 10 0665 Introduction 3 1 3 2 3 3 3 4 3 5 Parts Replacement Introduction This section of the service manual contains a list of replacement parts for the Viewstation OR network Available Replacement Parts and Assemblies Mindray DS USA Inc provides replacement parts at a board or assembly level In most cases individual components on boards and assemblies are not available Contact the Service Department or your local authorized Service Representative for additional details Product Variations Product variations due to differences in line voltages or option differences may require different components These variations
17. 10 0665 Viewstation ORTM Service Manual Instrument Description Introduction The Viewstation OR is capable of displaying the following waveforms as monitored by the Spectrum OR Up to seven waveforms of ECG dependent upon the ECG lead set that is being utilized Up to four waveforms of Invasive Blood Pressure One waveform of Pulse Oximetry SPO PON One waveform of Respiration 5 One waveform of CO The maximum number of waveforms displayable is 12 and the minimum number is 3 e Waveforms are acquired externally from the Spectrum OR and then presented to the Viewstation OR either directly by a crossover Ethernet cable or through an Ethernet Switch via the E LAN Protocol 1 1 3 Connectivity The Viewstation OR network is a single channel system that is designed for displaying patient data that is received from a Spectrum OR monitor via an Ethernet network Viewstation OR Service Manual 0070 10 0665 1 3 Viewstation OR Block Diagrams Instrument Description 1 2 Viewstation OR Block Diagrams The following block diagrams illustrate wired configurations for the Viewstation OR network 1 2 1 Basic Configuration The basic configuration is a network of devices that transmits patient data from a Spectrum OR monitor to a single independently configurable display As depicted in Figure 1 1 the basic configuration of the Viewstation OR is e Spectrum OR Monitor e Viewstation OR computer CPU Independent Dis
18. Cloth dampened with Semi Annually Clinical Engineer mild detergent Cables Inspect Bio Medical Semi Annually Clinical Engineer CPU ACTIVITY AREA ACTION TECHNICAL LEVEL METHOD SCHEDULE Cooling Fans Clean Bio Medical Forced air Semi Annually Clinical Engineer Power Supply Clean Bio Medical Forced air Semi Annually Fans Clinical Engineer Floppy Drive Clean Bio Medical Forced air Semi Annually Clinical Engineer Connections Inspect Bio Medical Semi Annually Clinical Engineer Case Inspect Bio Medical Semi Annually Clinical Engineer Cabling Inspect Bio Medical Annually Clinical Engineer Battery Replacement Information UNIT BATTERY TYPE TYPICAL LIFE Motherboard CMOS Lithium Coin cell CR2032 10 Years or equivalent 0070 10 0665 Viewstation ORTM Service Manual so Connections and 5 1 Hardware Installation Parts Configuration Viewstation ORT Service Manual 0070 10 0665 Hardware Installation Parts 5 1 Hardware Installation Parts Connections and Configuration This section of the manual covers the equipment interconnection and software configuration DESCRIPTION PART NUMBER 5 port switch 0992 00 0248 01 8 port switch 0992 00 0248 02 Mouse 0992 00 0233 01 KVM Extender 0992 00 0150 03 2 port Video Splitter 0992 00 0232 01 Touch Pad 0992 00 0238 01 ELO compatible Touch Screen Display 19 0160 00 0093 01 Ethernet Patch Cable 0012 00 1274 XX Ethernet Cross
19. IRQ5 2E8H IRQ10 Disabled Viewstation OR Service Manual Appendix B POWER MANAGEMENT SETUP CMOS Setup Verification ACPI Function Power Management Video Off Method Enabled User Defined V H Sync Blank Video Off In Suspend Yes Suspend Type Stop Grant Modem Use 3 Suspend Mode Disabled HDD Power Down Disabled Soft Off by PWR BTTN Instan Off CPU THRM Throttling 50 076 Wake Up by PCI Card Disabled Power On by Ring Disabled Resume by Alarm Disabled X Date of Month Alarm 0 X Time hh mm ss Alarm 0 0 0 Reload Global Timer Events Primary IDE O Enabled Primary IDE 1 Enabled Secondary IDE O Enabled Secondary IDE 1 Enabled FDD COM LPT Port Enabled PCI PIRQ A D H Enabled PNP PCI CONFIGURATIONS PNP OS Install No Reset Configuration Data Disabled Resources Controlled By Auto ESCD X IRQ Resources X DMA resources PCI VGA Palette Snoop Disabled PC HEALTH STATUS CPU Warning Temperature Disabled System Temp CPU Temp Chassis Temp CPU FAN Speed FAN1 Viewstation OR Service Manual 0070 10 0665 kk CMOS Setup Verification Appendix B PC HEALTH STATUS System FAN Speed FAN2 O RPM Chassis FAN Speed FAN3 O RPM Vcore V de VCC3 V W 5 V ER 12 V V 12 V Rx VBAT Ex 5VSB V W Shutdown Temperature Disabled CPU Fan Failure Warning Enabled Sys Fan Failure Warning Disabled Aux Fan Failure Warning Disabled FREQUENCY VOLTAGE CONTRO
20. L Auto Detect PCI Clk Disabled Spread Spectrum Modulated Enabled 7 6 0070 10 0665 Viewstation OR Service Manual Appendix B 12 7 2 1 7 2 1 1 7 2 1 2 7 2 1 3 7 2 1 4 7 2 1 5 7 2 1 6 7 2 1 7 Independent Display Functional Requirements Independent Display Functional Requirements Electrical Requirements Power Supply The power supply accepts the input voltage and frequency range of local power distributors such as 120VAC 60Hz for domestic US CANADA installations 230VAC 50Hz for European installations and 240VAC 50Hz for UK installations Display Resolution The independent display supports one of the following as a native resolution a 1920x 1080 b 1706 x 960 c 1366x768 d 1280x 1024 e 1024 x 768 Display Aspect Ratio The independent display supports at least one of the following image aspect ratios a 16 9 or 16 10 b 5 4 c 4 3 Color Support The independent display supports at least a 24 bit 16 7 million color palette Image Brightness The independent display image brightness is determined by the customer Image Contrast The independent display image contrast ratio is determined by the customer Viewing Angle The independent display Horizontal and Vertical viewing angles are determined by the customer Viewstation OR Service Manual 0070 10 0665 7 7 Independent Display Functional Requirements Appendix B 7 2 2 7 2 2 1 7 2 2 2 7 2 3 7 2 3 1 Mechanical Req
21. Service Manual Datascope Viewstation OR mindray NORTH AMERICA 0070 01 0665_revC indd 1 3 10 10 5 38 13 PM Service Manual Datascope Viewstation OR NORTH AMERICA Microsoft and Windows are US registered trademarks of Microsoft Corporation Spectrum OR is a US trademark of Mindray DS USA Inc Viewstation OR is a U S trademark of Mindray DS USA Inc Copyright Mindray DS USA Inc 2008 All rights reserved Contents of this publication may not be reproduced in any form without permission of Mindray DS USA Inc 0070 10 0665 Viewstation OR Service Manual Table of Contents FOPEW Ol DEE v Warnings Precautions and Notes iie eerte te HE EIS e sde En SENEE EKARTEA e e Re EEEE R e v Warning Seane freie tette os ean Pee gine tut ANNO vi PRECAUTIONS eem EE EL m M E vii HowTo Gestalt nen n eR utin trs eh eS ii Instrument Description OUCH OM EE 1 2 uM EUER 1 2 Core Functions 1 2 VE m 1 3 Vi wstation OR Block Diagrams nectit ate e e ea Ud et at ec d qoe dtr a ete 1 4 Basic Configurations s eee e ere A ree N elt ee 1 4 Multiple Display Gonfig rdlion 7 ciu dr Pos o eile e aedibus 1 5 System Modules Components and Peripherie 1 5 Viewstation OR CPU 5s e oe ROGO Ep tenet utente eei ates 1 5 Keyboard Video and Mouse Touch Pad KVM Exiender 1 5 Network Switches 1 6 Mouse Touch Pad 1 6 Bp e ed de e ld ite dela e SE 1 6 Supplied ELO Compatible Touc
22. Service Manual 0070 10 0665 6 3 Installing Viewstation OR Software Appendix A 9 After re booting the desktop will be visible and then the first IDS System Config Tool will open see FIGURE 6 2 D ET m IDS System Config Tool Screen Setup IP Address Exit Display Resolution 1024 x 768 32 bits 75hz ELAN IP Address HEN Bixee BE od r Display Calibration r Language Configuration p Emergency Disk 4 Calibrate Ruler To Screen Size a inguage sen enn Create Load English United States v Ruler xe Vertical SI Database Operations Factory Default Date Time 7 Set Date Time Format pan roma System Password Setup MM_DD_YYYY Time Format Change Password HH MM x FIGURE 6 2 DS System Config Tool 10 Set the ELAN IP address 7 6 6 1 is the default IP address Change the address to avoid any future IP address error 11 Select the Screen Resolution from the Screen Setup list box NOTE The Screen Setup drop down list box will only show supported display resolutions 0070 10 0665 Viewstation OR Service Manual Appendix A Installing Viewstation OR Software 12 Using the 15 cm ruler calibrate the Vertical and Horizontal rulers for the proper screen size on the Independent display 13 Select the Date and Time formats 14 The default system password is system If
23. an or the auxiliary fan is noisy or turns too slowly replace that component The Power Supply should be replaced as an assembly rather than replacing its internal fan Motherboard Backup Battery Replacement Locate the battery BT1 on the motherboard Remove the battery from its socket and install a new battery observing the proper polarity The CPU s CMOS settings will have reset to the manufacturer s defaults and must be changed to meet company requirements This must be accomplished prior to returning the unit to use See CMOS Setup Verification on page 7 2 Viewstation OR Network Verify the mechanical integrity of all cables wires and network connections including bedside monitors Replace any frayed or kinked cables Test communication integrity with a network analyzer or cable tester Check and verify the proper operation of the Status and System LEDs on all switches Viewstation OR Service Manual 0070 10 0665 System Maintenance 4 4 4 4 1 Preventative Maintenance System Maintenance Preventative Maintenance The Viewstation OR network requires periodic cleaning inspection and testing Use the following tables for each maintenance procedure Displays ACTIVITY TECHNICAL AREA ACTION LEVEL METHOD SCHEDULE Screen Clean User See Operators manual As required P N 0070 00 0663 01 Touch Calibrate User Built in system software As required Screen Case Clean Bio Medical
24. are reflected where necessary on the parts lists Exchange Program Mindray DS USA Inc offers an exchange program for many circuit boards and assemblies This program provides the most expedient method of servicing the equipment A standard charge for this service is made Contact the National Repair Center in Mahwah New Jersey for details concerning this program The printed circuit boards make extensive use of multi layer and surface mount technology Individual component replacement is not recommended on these boards Board exchange or replacement is the most efficient method of repair for these types of assemblies Circuit board and assemblies that show evidence of improper repair techniques and that are damaged in the process are not considered for exchange Damaged boards are invoiced at full value and no exchange credit is applied Parts Pricing Information Current replacement parts and exchange charges are determined by contacting the Order Entry Department 0070 10 0665 Viewstation ORTM Service Manual Parts Replacement 3 6 Viewstation ORT Service Manual Ordering Information Replacement parts and assemblies are available Please follow these guidelines when ordering replacement items for the Viewstation OR network PON Include the description of the part Include the unit s model and serial number Include the software part number and revision Include the part number exactly as it appears in
25. ation OR CPU Insert the software installation CD and boot up the Viewstation OR CPU Select Full Install option Pon Select Yes for the Are you sure message a Wait for the Ghost process to complete b c When the Remove CD and reboot message displays remove the CD and verify the HDD LED is not illuminated d Press the Ctrl Alt and Del keys A message will appear prompting to press any key to re boot Wait for the additional files to be copied Press any key to re boot the system 0070 10 0665 Viewstation ORTM Service Manual Appendix A Installing Viewstation OR Software 5 After the re boot the IDS System Installer window opens see FIGURE 6 1 IDS System Installer Name Serial Number r Display Configuration Single Display Dual Display Install FIGURE 6 1 IDS System Installer Window NOTE Before typing any information turn off the Num Lock on the keyboard 6 Enter the system name in the Name field This name must be unique within the entire Hospital and Panorama networks The name must contain only numbers and letters and can be no more than 15 characters long 7 Type the serial number located on the front panel of the computer in the Serial Number field Do not use the dash in the serial number 8 Click the Install button When the installation is complete the IDS System Installer window closes and the system will re boot Viewstation ORT
26. ce ID number This number will be entered into the Viewstation OR Equipment Setup Tab Return to the previous menu by choosing Previous Menu Save the information by pressing Save Current Power cycle the monitor Viewstation ORT Service Manual 0070 10 0665 5 5 Connections and Configuration Connections and Configuration This page intentionally left blank 5 6 0070 10 0665 Viewstation ORTM Service Manual co Appendix A 6 1 Installing Viewstation OR Software eere O72 Viewstation OR Service Manual 0070 10 0665 Installing Viewstation OR Software Appendix A 6 1 6 1 1 6 1 1 1 6 1 1 2 6 1 2 Installing Viewstation OR Software Introduction Required Parts and Equipment DESCRIPTION PART NUMBER Software Installation Disc Viewstation OR 0996 00 0170 0001 15 cm ruler part of accessory kit 0353 00 0004 01 Prerequisites 1 The Spectrum OR monitor must be configured to communicate with the Viewstation OR CPU The Enable Network must be set to wired A valid IP address and SubNet Mask must be entered 2 All components of the system must be connected prior to installing the software Spectrum OR monitor Independent display and mouse touch pad e KVM extender Ethernet network Software Installation NOTE It is imperative that you read and perform the steps listed in the Prerequisite section prior to starting the sofrware installation Remove the front cover from the Viewst
27. d unit and cause damage Remove fingerprints and stains by using a liquid lens cleaner and a soft cloth To prevent scratches on the front panel of the display screen observe the following precautions when cleaning DO NOT use abrasive cleaning materials to clean a touch screen DO NOT wipe a dry screen DO NOT use alcohol or chlorinated hydrocarbon solvents Use a fine softhair brush to carefully brush away dust and dirt particles Use a soft sponge moistened with cleaner solution to wipe the touch screen clean 0070 10 0665 Viewstation ORTM Service Manual Preventative Maintenance 4 2 4 2 1 4 2 2 4 2 3 4 2 4 4 3 Viewstation OR CPU Viewstation OR CPU The following internal cleaning procedures should only be performed by a trained qualified electronic technician Turn off the AC power and unplug the AC main power cord and all other cables from the rear panel from the Viewstation OR CPU before attempting internal cleaning Clean the display in an area free of blowing dust dirt and lint Cleaning Use an anti static vacuum to carefully remove accumulated dust dirt and lint from the various surface areas Be careful not to dislodge components connectors or printed circuit boards Visual Inspection Perform a visual check to verify that all dust dirt and lint has been completely removed and that connectors and printed circuit boards PCBs are properly seated Fans If the power supply f
28. e Memory Frequency For System BIOS Cacheable Video BIOS Cacheable Delay Transaction Delay Prior to Thermal AGP Aperture Size MB ICH4 LAN On Chip VGA 0070 10 0665 Disabled Enabled Enabled Floppy CDROM HDD O Enabled Disabled Disabled On Fast Disabled 6 250 Setup Enabled 1 4 Non OS2 Yes Enabled By SPD 2 5 7 3 3 AUTO Enabled Enabled Enabled 16 Min 64 Enabled On Chip VGA Setting Enabled CMOS Setup Verification ADVANCED CHIPSET FEATURES On Chip Frame Buffer Boot Display INTEGRATED PERIPHERALS On Chip Primary PCI IDE DE Primary Master PIO DE Primary Slave PIO DE Primary Master UDMA DE Primary Slave UDMA On Chip Secondary PCI IDE DE Secondary Master PIO DE Secondary Slave PIO DE Secondary Master UDMA DE Secondary Slave UDMA USB Controller USB 2 0 Controller USB Keyboard Support AC97 Audio Init Display First IDE HDD block Mode POWER ON Function X Hot Key Power On Onboard FDC Controller Onboard Serial Port 1 Onboard Serial Port 2 UART Mode Select Onboard Parallel Port Parallel Port Mode PWRON After PWR ail Onboard Serial Port 3 Serial Port 3 Use IRQ Onboard Serial Port 4 Serial Port 4 Use IRQ Digital I O 0070 10 0665 Appendix B 8 MB Auto Enabled Auto Auto Auto Auto Enabled Auto Auto Auto Auto Enabled Enabled Disabled Auto PCI Slot Enabled BUTTON Only Ctrl F 1 Enabled 3F8 IRQ4 2F8 IRQ3 Normal 378 IRQ7 SPP Off 3E8H
29. endent Display All text and graphics are presented on an Independent Display that utilizes an external AC power supply Graphics information is transmitted through a graphics cable from an AGP Graphics Card The Independent Display follows the specifications detailed in section 7 2 Independent Display Functional Requirements 0070 10 0665 Viewstation ORTM Service Manual z0 Repair Information 2 1 Introduction eee eee eee eee eee eene eene e sess osse se eesesssseeeeeeessssss ees 2 2 2 2 Safety Precautions eeee esee eee eee ee eee eee esos es esso eeeesssssseeeeesssssse 272 2 3 Equipment and Special Tools Required ccccccccccscccsccscccccees 2 2 2 4 Troubleshooting ccce e eee eee e eee eee e eee eee sees essoeseesseseessse sees 2 3 2 5 Disassembly Instructions ecce ee eee eee eese eee sese eseseeesseseess 276 2 6 Re assembly Instructions eeeee ee eee eee eee e ees eee eessscssesssseess 2 8 Viewstation ORT Service Manual 0070 10 0665 Introduction 2 1 2 2 2 3 Repair Information Introduction This section provides the necessary technical information to perform repairs to the system The most important prerequisites for effective troubleshooting are a thorough understanding of the system functions and the theory of operation If necessary refer to the appropriate Viewstation OR Operating Instructions Manual P N 0070 00 0663 01 which d
30. ervice Manual zo 9 Preventative Maintenance 4 1 ELO Compatible Touch Screen Displays eere eere eene 4 2 4 2 Viewstation OR CPU ccce esee eene eee ee eee ee eee sese sesso sese see eose seno 4 3 4 3 Viewstation OR Network e ceee ee eee eee eee eee ee eese sese sose se ssoe 4 3 4 4 System Maintenance eee e eene e eee e eee nn eene e sese sese esses KEE EE eeon 4 4 Viewstation ORT Service Manual 0070 10 0665 ELO Compatible Touch Screen Displays Preventative Maintenance 4 1 4 1 2 ELO Compatible Touch Screen Displays The display panel and housing should be cleaned as required but at least semi annually The following internal cleaning procedures should only be performed by a trained qualified electronic technician NOTE Never use an abrasive glass cleaner containing highly concentrated ammonia and strong base chemicals since they damage the surface treatment WARNING Do not clean the display while it is ON and or plugged in Care and Cleaning of an LCD Display Clean the LCD display with a lightly moistened soft cloth Care and Cleaning of a Touch Screen For the best performance it is recommended that the touch screen display s be kept clean You can use any standard glass cleaner to clean the screen Always remember however to use a cloth or towel to apply the cleaner Glass cleaner sprayed directly on a display could possibly leak inside a non seale
31. escribes instrument functions and features in full detail Safety Precautions In the event the instrument covers are removed make certain you observe the following warnings and general guidelines Do not short component leads together e Observe proper ANTI STATIC precautions Equipment and Special Tools Required You will need the following equipment and or special tools when performing repairs on the system e Anti Static Wrist Strap e Anti Static Mat e 1 Phillips Screwdriver e 2 Phillips Screwdriver e Slotted Screwdriver Laptop Computer with 100MB Network Interface Card used for network troubleshooting 0070 10 0665 Viewstation OR Service Manual Repair Information Troubleshooting 2 4 Troubleshooting Prior to troubleshooting a network problem check the following areas All AC and DC power connections are secure All Ethernet cable connections are secure e Affected cable runs should be tested with a cable tester for continuity IP addresses e Valid IP addresses should be verified for all devices on the Panorama Patient Monitoring Network Bedside monitor configuration Network configuration should be verified within the monitor s installation menu Refer to Spectrum OR Communication Configuration on page 5 5 of this service manual Viewstation OR configuration Patient and IP address configuration should be verified The display or the Viewstation OR CPU does not come ON A u
32. h Screen Display sss ee 1 6 Customer Supplied Compatible Displows 1 6 Theory of Opergfiori sea eo agde dla lote avete eee ee a epe bae qe 1 7 CPU uten ee REB tueatur Ra epe Deed 1 7 Motherboard E 1 8 Motherboard connections via PCI and AGP connectors 1 8 iH c 1 8 CDROM Drive nonce ain eU eh edita Rivas OC wee ates 1 8 AGP Graphics Dual Display Card rte rate river i i ede vele shades bs ete kr Reds 1 8 ATX Power Suppl yz esse ia td EP T P Pn RD ERR EE t Eget 1 8 35 inch e 1 8 InideperidentiDISplay sssa ege RT EDAD p Restos os dd eta aine d rues 1 8 Repair Information 1 Introduction EE 2 SIE 2 2 Equipment and Sp cial Tools Requited ai ai 2 2 lire irem PE 2 3 Disassembly Instructions 42 6 Cover Removal ui li e eee ee bise ape eee e eo PE Yee cede oe eb im ie spa etd eee oes 2 6 Front Panel Removal 2 da T aee d qi pae D eti aora din qai tes 2 6 Power Supply Removal 55 5 bilis m HR i pa ec Vp A EN E i Ee io e petes 2 6 AGP Video Board Removal eb een eie denen eii at Ee HR 2 6 Abxiliary Fan Removal id ls did 2 6 System Hard Drive EE 2 6 Floppy Drive and Disclosure Hard Drive s Remo 2 6 CD ROM Drive Removal 2 7 Motherboard Removal 2 7 Re assembly Instructions sco tense ho ech a obe ee ab ad e SEA 2 8 Motherboard Assembly 5 5 de 2 8 AGP Video Board Assembly et itte EE hte tilde 2 8 Power Supply Assembly itt ote t
33. he physical platform on which the computer s electronic circuitry and processors reside The computer s microprocessor is docked on the motherboard The microprocessor executes the application software The following components also reside on the motherboard Random Access Memory RAM e Read Only Memory Basic Input Output System ROM BIOS e Associated Processing Logic e EIDE controller for 3 5 floppy drive and system hard drives e Mouse touch pad and keyboard controllers Network Interface Ports e Comm Ports Motherboard connections via PCI and AGP connectors e Serial Interface Comm Ports e AGP Graphics Display Card System Hard Drive The system hard drive stores the Operating System Windows XPE and Viewstation OR application software It is controlled by EIDE controller circuitry on the motherboard CD ROM Drive The CD ROM drive is used to load software and to copy error logs It is controlled by EIDE controller circuitry on the motherboard AGP Graphics Dual Display Card The AGP Graphics Display card sits in the J19 slot on the motherboard ATX Power Supply The ATX switching Power Supply provides power for all electronic assemblies within the Viewstation OR CPU Regulated voltages are 5 5 12 and 12 Volts The power supply has a universal AC input and is rated for 460 Watts minimum 3 5 inch Floppy Drive This drive is installed in the system but is not currently used for any applications Indep
34. iewstation OR will cause the application to no longer be suitable for medical patient monitoring use Do not connect or attempt to connect or reconfigure any equipment to the Viewstation OR unless Mindray DS USA Inc has explicitly approved the hardware in writing This includes all commercially available networking hardware i e switches routers etc or peripherals i e Printers even if they are the same brand as recommended by the configuration of the system and supplied by Mindray DS USA Inc Do not attempt to load any devices or device drivers onto the Viewstation OR If the user connects or attempts to connect any equipment to the Viewstation OR it may not operate as intended Only qualified and trained Service Personnel should attempt to service the equipment Service is defined as any activity requiring the cover to be removed for internal adjustments parts replacements repairs or software upgrades of any kind to insure compatibility To insure compatibility with the operating system and applications software use only supplied and or approved components to repair any part of the Viewstation OR Use of unauthorized software devices accessories or cables other than those approved may render the application unsuitable for medical patient monitoring It may also result in increased electromagnetic Emissions or decreased Immunity of the system All of the equipment on the Viewstation OR network must utilize the hospital e
35. it needs to be changed press the Change Password button fill out the fields and press OK see FIGURE 6 3 System Password Dialog x Old Password New Password Confirm Password Cancel FIGURE 6 3 System Password Dialog 15 After the Password Dialog closes click on the Save Configuration button to save NOTE If a new display resolution was selected during configuration it will be set when the Save button is pressed 16 Click on the real time clock in the lower right hand corner of the display to set the current date and time for the Windows system Select the OK button when all changes have been made do not alter the time zone setting NOTE When in the monitoring mode the Viewstation OR will display the connected monitor s time If no patient is admitted the time will not be displayed 17 IF the Viewstation OR network is setup to communicate to the Spectrum OR monitor through a crossover CATS cable the Viewstation OR ELAN network card speed setting must be re configured NOTE If the Viewstation OR is connected to the Spectrum OR monitor via an ELAN switch no configuration changes are required the system is defaulted to 100Mbps Full Duplex Skip to step 18 To change this setting Press the Start key in the lower left of the display Press Control Panel Double click on the Network Connections Icon Right click on the ELAN connection Press Properties Click on the Configure but
36. itter use VGA to VGA cables to connect the 2 VGA output ports to the displays If a display has a touch screen connect the touch screen cable from PO on the CPU to the touch screen connector on the display e If the distance between the Viewstation OR CPU and the displays is more than 50 ft a Longview Companion will be used If the display has a touch screen connect a touch screen cable from PO on the Viewstation OR CPU to the KVM transmitter female serial port Attach the touch screen cable from the serial port on the receiver to the touch screen port on the display 0070 10 0665 Viewstation ORTM Service Manual Connections and Configuration 5 2 4 Connections and Configuration Spectrum OR Communication Configuration In order to communicate to the Viewstation OR CPU each Spectrum OR must be configured for Ethernet protocol and have an IP Address and Subnet Mask ID assigned to it Follow the instructions for configuring a bedside monitor for wired networks Enter the Installation Menu by pressing and holding the TRENDS key during power up Release the TRENDS key when the Installation Menu appears Go to the System Information Sub Menu Set Enable Network to Wired Enter an IP Address that matches the IP Address scheme 7 6 6 X where X any number from 2 to 255 Do not duplicate an existing IP address that has been assigned to any other device on the network Ensure that the Subnet Mask ID is 255 255 255 0 Record the Devi
37. mergency power system Failure to do so will result in loss of monitoring during extended periods of power failure Do not put MPSOs Multiple Portable Socket Outlets i e multiple outlet extension cords used with the Viewstation OR on the floor Do not overload MPSOs Use only MPSOs that comply with the requirements of IEC 60601 1 1 Do not clean the display while it is ON and or plugged in Disconnect AC power prior to any disassembly 0070 10 0665 Viewstation OR Service Manual Precautions Introduction Precautions CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION This system is intended for use in a hospital or clinical setting and to be operated by trained and authorized personnel who are acting on the orders of a physician Its purpose is the real time monitoring of a patient s physiological parameters For proper operation do not obstruct the fan air holes For proper operation never place fluids on top of this equipment In case of accidental spillage wipe clean immediately and have the system serviced to ensure no hazard exists For proper operation do not use any components of the Viewstation OR network with a frayed or damaged power cord Do not operate the Viewstation OR or any of its components if they have been dropped or the case has been damaged Use only the supplied power cords If a substitute is necessary only use Hospital Grade power cord
38. nnector 7 Connect the 34 pin ribbon cable from the Floppy drive to the FDD1 connector 8 Connect the ribbon cable from PO serial port to J15 on the motherboard 9 Connect the ribbon cable from P1 serial port to J16 on the motherboard 10 Connect the ribbon cable from the unmarked serial port to J11 on the motherboard 11 Connect the speaker connector to pins 1 4 red to pin 1 on J20 12 Connect the power LED connector to pins 11 13 green to pin 11 on J20 13 Connect the power switch connector to pins 7 and 17 blue to pin 7 on J20 14 Connect the HDD LED connector to pins 10 and 20 black to pin 10 on J20 AGP Video Board Assembly 1 Plug the Graphics adapter into the AGP slot on the Motherboard 2 Secure the board to the chassis using one 1 screw Power Supply Assembly Secure the power supply to the rear of the chassis with 4 screws Connect the ATX power supply connector to J10 on the motherboard e Connect the ATX 12 V power connector to J12 on the motherboard A L NM Plug a power connector onto each hard drive and into the floppy drive Floppy Drive 1 Install the replacement drive into the drive rack and secure with four 4 screws 2 Connect the power and ribbon cables to the rear of the drive 3 Slide the drive rack into the front of the chassis Secure the drive rack with three 3 screws 4 Install a cable retainer bracket to each of the drives 5 Tighten the screws that secure the cable
39. over Patch Cable 0012 00 1392 XX Ethernet Cable UTP Plenum Bulk 0175 00 0095 XX 0175 00 0096 XX Ethernet Cable UTP Non Plenum Bulk Extension VGA Cable 0012 00 1629 XX VGA cable Male to Male 10 FT 0012 00 0994 01 0070 10 0665 Viewstation OR Service Manual Connections and Configuration Connections and Configuration 5 2 Connections and Configuration Mouse Keyboard E LAN Monitor 1 Touch Screen PO FIGURE 5 1 Viewstation OR CPU Connections 5 2 1 Touch Pad Mouse and AC Power Cable Connection The following touch pad mouse and AC power cable connections to the Viewstation OR CPU are common for all configurations e A touch pad or mouse attached to the PS2 mouse port on the Viewstation OR CPU will be used to navigate An optional PS2 extender cable is available The AC power cable attached to the Viewstation OR CPU is connected to the hospital emergency power supply 5 2 2 Spectrum OR Connection to Viewstation OR CPU e For each Spectrum OR that is connected directly to the Viewstation OR CPU a crossover Ethernet patch cable is used The cable connects the CS1 port of the Comm Port on the Spectrum OR to the patient network port on the Viewstation OR CPU e For each Spectrum OR that is connected to the Viewstation OR CPU through an Ethernet switch straight Ethernet patch cables are used One cable connects the CS1 port on the Comm Port of the S
40. pectrum OR to an open port on the switch A second cable connects an open port on the switch to the patient network port on the Viewstation OR CPU Viewstation OR Service Manual 0070 10 0665 5 3 Connections and Configuration Connections and Configuration 5 2 3 5 2 3 1 5 2 3 2 Display Connection to Viewstation OR CPU Single Display The display is connected to the Monitor 1 port on the Viewstation OR CPU as follows e If the distance between the Viewstation OR CPU and the display is less than 50 feet a VGA to VGA cable is used Additionally if the display is a touch screen connect a touch screen cable from PO on the Viewstation OR CPU to the touch screen port on the display e If the distance between the Viewstation OR CPU and the display is more than 50 feet a KVM Extender is used Additionally if the display is a touch screen connect a touch screen cable from PO on the Viewstation OR CPU to the KVM transmitter female serial port Then attach another touch screen cable from the serial port on the KVM receiver to the touch screen port on the display Two Displays Both displays must have the same resolution and aspect ratio The distance between the Viewstation OR CPU and the display must be less than 50 feet to use this configuration Connect one end of a VGA cable to the Monitor 1 port on the Viewstation OR CPU see FIGURE 5 1 and connect the other end to the Video Input port of the video splitter From the video spl
41. play Touch Pad INDEPENDENT DISPLAY TOUCH PAD LJ CPU SPECTRUM OR MONITOR FIGURE 1 1 Basic Components of the Viewstation OR The basic configuration can be varied to include two identically configured displays per Viewstation OR computer and may also access the Spectrum OR monitor through an Ethernet network switch see Figure 1 2 4 0070 10 0665 Viewstation ORTM Service Manual Instrument Description System Modules Components and Peripherals 1 2 2 Multiple Display Configuration SPECTRUM OR MONITOR ELAN T BL EN seen TO PANORAMA PATIENT SWITCH ER MONITORING NETWORK OR GATEWAY CPU VIDEO CPU i em mm m TOUCH SCREEN ee deal ee TOUCH PAD TOUCH PAD FIGURE 1 2 Example Multiple Display Configuration of the Viewstation OR 1 3 System Modules Components and Peripherals 1 3 1 Viewstation OR CPU The application software and the Windows XP Embedded operating system reside on the system hard drive within the Viewstation OR CPU Independent displays provide a graphic display of patient waveforms and other data 1 3 2 Keyboard Video and Mouse Touch Pad KVM Extender e The KVM Extender is used when displays keyboard and mouse touch pad are not located in the same room as the Viewstation OR The KVM Extender consists of a transmitter and receiver connected via CAT5 cable e The transmitter is located with the Viewstation OR CPU
42. ret terr a iet be e bone e A er eae 2 8 Floppy RE 2 8 CD ROM Drive and System Hard Drive sss em eee een eene eren rne Erika 2 8 Viewstation OR Service Manual 0070 10 0665 i Table of Contents Auxiliary Egger cd 2 9 CMOS Battery Replacements Se entier eaten haee en E ode EN ERE Nt RBS EN Fe ERIS ENSK s spends 2 9 Closing ET 2 9 R booting and Testing the System cecinere tectae rto oig en a ehe e doeet cete see ert eoa 2 9 Parts Replacement ecce ee eee eee eee eee e eee eese sse se esso sese osse se ssosesesseseeesseeeeesseoeeessceeesssseessss s S T hires pec E 3 2 Available Replacement Parts and Assemblies csse em eme emere nnne 3 2 Product Variations eege Et o I ide ned er eve eee e de o ME bci t RO E adeptes 2 Exchange Program 2 Parts Pricing Information 2 Ordering Information rasa chem ege attt e e dan ds ovdi een o Leto 3 3 Preventative Maintenance eeeee ee eee eere reete eee eee eese eese esee eee eesosssssesesscse eee eeeeeeeeeeeeeeeeeee A 1 ELO Compatible Touch Sereen Displays cta iii Care and Cleaning of an LCD Display Care and Cleaning of a Touch Screen MD niger E EE Cleaning doas eU E M o EM nC NONU Me HIE Visual Inspection aeo ep n P ere pe ep t E e ap Rp ed pei e PA Ee Ra Cub ations Motherboard Backup Battery Replacement Viewstation OR Hebwork seeeesereereerree System ihi vi cies sevssesievuacsessdonsviw
43. s For proper operation use only approved accessories with this product Dispose of single use items in accordance with hospital policy Proprietary software is written directly to some of the PC boards within the CPU Replacement of the PC boards with off the shelf PC boards may compromise the proper operation of the Viewstation OR How To Get Help Mindray DS USA Inc maintains a worldwide network of Sales Clinical and Service representatives For U S Canada and Latin America please contact Mindray DS USA Inc Sales Tel 800 288 2121 800 MacArthur Blvd Sales Fax 800 926 4275 Mahwah NJ 07430 Sales Tel 201 995 8237 Sales Fax 201 995 8659 Service Tel 800 288 2121 Service Fax 201 995 0119 For International Offices refer to the contact information at the end of this service manual Viewstation OR Service Manual 0070 10 0665 vii Introduction How To Get Help This page intentionally left blank viii 0070 10 0665 Viewstation ORTM Service Manual 10 Instrument Description 1 1 Introduction A 1 2 1 2 Viewstation OR Block Diagrams 4 ee eee eee eee eee e eee eee teu 1 4 1 3 System Modules Components and Peripherals 1 5 1 4 Theory of Operation e eee eese eee eee eee ee ente eese sesso ette ees ss sos eee 1 7 Viewstation ORT Service Manual 0070 10 0665 Introduction 1 1 Instrument Description
44. t e Use of the touch screen does not preclude the use of a mouse or touch pad 1 3 5 2 Customer Supplied Compatible Displays e See Appendix B or contact Customer Support for requirements 1 6 0070 10 0665 Viewstation ORTM Service Manual Instrument Description Theory of Operation 1 4 Theory of Operation The system design is based on an ATX computer architecture Basic system data processing configuration includes an ATX computer an Independent Display with Mouse Touch Pad and an Ethernet distribution network CAUTION Proprietary software is written directly to some of the PC boards within the CPU Replacement of the PC boards with off the shelf PC boards may compromise the proper operation of the Viewstation OR 1 4 1 CPU Each of the Viewstation OR CPU hardware items e g hard drives controls etc are identified below The hardware is marked with labels identifying all connections FRONT FIGURE 1 3 Viewstation OR CPU Internal Side View 1 ATX Power Supply 7 CD ROM Drive 2 Microprocessor Heat Sink Fan 8 Memory Modules 2 3 12V power input 9 ATX Power Connector 4 AGP Video Card 10 System Hard Drive 5 PCI 1 not used 11 IDE 1 connector 6 PCI 2 not used 12 IDE 2 connector Viewstation OR Service Manual 0070 10 0665 1 7 Theory of Operation 1 4 2 1 4 2 1 1 4 3 1 4 4 1 4 5 1 4 6 1 4 7 1 4 8 Instrument Description Motherboard The motherboard is t
45. tion OR CPU While the memory test is being performed press the Del key on the keyboard to enter the CMOS Setup menu Follow the on screen instructions to move through the menus and setup or verify the CMOS exactly as it appears below When completed select SAVE to CMOS and EXIT to enter these settings into memory BIOS SETUP Pentium 4 Motherboard STANDARD CMOS SETUP Date mm dd yy Set to current Date Time Set to current Time IDE Primary Master ST380021A IDE Primary Slave ST3200822A IDE Secondary Master LITE ON LTR 522465 or L TR 523275 IDE Secondary Slave None Drive A 1 44M 3 5 in Drive B None Video EGA VGA Halt On All But Keyboard Base Memory 640K Extended Memory 1047552K Total Memory 1048576K 0070 10 0665 Viewstation ORTM Service Manual Viewstation OR Service Manual ADVANCED BIOS FEATURES CMOS Setup Verification Virus Warning CPU L1 and L2 Cache Quick Power On Self Test First Boot Device Second Boot Device Third Boot Device Boot Other Device Swap Floppy Drive Boot Up Floppy Seek Boot Up Numlock Status Gate A20 Option Typematic Rate Setting X Typematic Rate chars Sec X Typematic Delay Msec Security Option APIC Mode MPS Version Control for OS OS Select For DRAM gt 64MB Report No FDD For WIN 95 Small Logo EPA Show ADVANCED CHIPSET FEATURES DRAM timing Selectable X CAS Latency Time X Active to Precharge Delay X DRAM RAS to CAS Delay X DRAM RAS Precharg
46. ton next to the Network adapter name Viewstation OR Service Manual 0070 10 0665 6 5 Installing Viewstation OR Software Appendix A Select the Advanced Tab see FIGURE 6 4 for reference e Select the Link Speed amp Duplex In the value window select 100Mbps Half Duplex Press OK to save the setting Intel R PRO 1000 MT Desktop Adapter Properties Adaptive Inter frame Spacing 100Mbps Full Dupl 1000Mbps Full Duplex 100Mbps Full Duplex Seer T 100Mbps Half Duplex a 10Mbps Full Duplex Locally ed Address Log Link State Event Pone i Duplex Offload Receive IP Checksun ome Offload Receive TCP Checks Offload TCP Segmentation Offload Transmit IP Checksui Offload Transmit TCP Checks QoS Packet Tagging Receive Descriptors FIGURE 6 4 Network Connections Window Close the Network Connection window 6 0070 10 0665 Viewstation OR Service Manual Appendix A Installing Viewstation OR Software 18 Restart the Viewstation OR CPU as follows a Press the Start button in the lower left corner of the display b Press the Shut Down icon in the dialog box c From the pulldown menu select Restart and press the OK button The system should restart in normal display mode see the example in FIGURE 6 5 NOTE The example in FIGURE 6 5 depicts waveforms and digital data from a Spectrum OR that is actively monitoring a patient Patient data may not be displayed depending on the current monitoring status of the Spectrum OR
47. uirements Connectors Cable Termination at the Viewstation OR PC The independent display includes a display video interface cable 6 ft length minimum The cable must terminate at the Viewstation OR CPU with a standard analog video input 15 pin HD15 VGA male connector for analog RGB Mounting The mounting method of the independent display is determined by the customer Environmental and Agency Requirements Compliance Operating Temperature Humidity amp Elevation Requirements REQUIREMENT DESCRIPTION TEST LIMITS amp NOTES Temperature 10 to 40 degrees Celsius Humidity 20 to 80 non condensing Safety It is recommended that the independent display comply with the requirements of Council Directive 93 42 EEC Medical Device Directive MDD for safety and electromagnetic emissions and immunity If the customer chooses a display that only meets the safety requirements of UL 60950 1 CSA C22 2 No 60950 1 for EU Council Directive 73 23 EEC then a medical isolation transformer must be installed in series with the display s power supply and the AC mains if the display is in the Patient vicinity With either MDD for US CAN UL 60601 1 or 73 23 EEC for US CAN UL 60950 1 CSA C22 2 No 60950 1 compliance the external labeling shall indicate that the display has been tested to and successfully passed those requirements by bearing the UL C UL CSA mark or any other NRTL approved agency mark s The display will
48. usedsasyaueos EEN S EE EEN deegsde duslead sivas RERE IRELE NIE EENEI NEE EES EEan iiaeie Preventative Mainienance eet rete ppt eee e e e rr OO Seedy ben eere ev souk Ee Connections and Configuration ee eee eee esee eee eene eee eee eee e eese ss sso see eesessssseseeeesesssseseeeessesss D 1 Hardware Installation Parts 5 eit nene ene deter eee ed e ea eue aee rie EL Ea e a Ei S 5 2 Connections dnd Configuration tdi ela Rant tete dt tv OR UR gd 5 3 Touch Pad Mouse and AC Power Cable Connechon otr S rI Ir I rI rr I rr rr r rrrrrrrrEnt 5 3 Spectrum OR Connection to Viewstation OR CPU eem een een eene 5 3 Display Connection to Viewstation OR CRU 5 4 Single Display eed ret ostende tn tet aia Festo eee dq 5 4 Two Displays Tett eee b a da D dd es avn A oT eben Beh cat d dts 5 4 Spectrum OR Communication Configuration sese Appendix A eee e ee eee eee eene InstallingViewstation OR Soltware 2 2 sas eee coe a am dat elim eam ae PRO d en enit Introduchon ETE Required Parts and Equipment Prerequisites socios iii E Software Installation ee sae o pete e Sa Eet dE ee Appendix B MM P A CMOS Setup Verification 5 4 1er teet eee ee te Rd eh nte odo ea gen tn d o e erede 7 2 BIOS SETUP Pentium A MotherBGGra s sitos estote te ott et Lo RS fonts 7 2 Independent