Agilent 4263B LCR Meter 100 Hz to 100 kHz
Contents
1. 0120 421 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe amp Middle East Austria 0820 87 44 11 Belgium 32 0 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 0 10 855 2100 France 0825 010 700 0 125 minute Germany 01805 24 6333 0 14 minute lreland 1890 924 204 Israel 972 3 9288 504 544 Italy 39 02 92 60 8484 Netherlands 31 0 20 547 2111 Spain 34 91 631 3300 Sweden 0200 88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 0 118 9276201 Other European Countries www agilent com tind contactus Revised March 27 2008 Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 1995 2000 2003 2004 2008 Printed in USA April 15 2008 5964 6181E Bee Agilent Technologies
2. Other instrument functions Test signal level monitor Voltage current Error Correction Open Short Load Comparator HIGH IN and LOW for each displayed parameter Save recall 10 instrument states from non volatile memory Front end Protection Vmax V 8 C Vmax lt 250 V Vmax V 276 Vmax lt 1000 V C in Farads Handler interface Negative logic and isolated Signals are HIGH IN LOW No Contact EOM Index Alarm Keylock Ext Trigger GPIB interface Instrument control TALK only mode for LISTEN only printers using GPIB or Centronics GPIB converter Physical characteristics Power 90 132 Vac or 198 264 Vac 47 66 Hz 45 VA typical Operating temperature 0 to 45 C Dimensions 320 W x 100 H x 300 H mm Weight 4 5 kg typical Test Fixtures Accessories for the Agilent 4263B 16060A transformer test fixture 16065C external bias adapter 16089C Kelvin IC clip leads Allows fast connections to For external dc bias of DUT Vmax IC package clip 1 meter length transformers lt 40 Vdc 16089A Kelvin clip leads 16034G Test fixture Large clip 1 meter length For SMD components 16089B Kelvin clip leads Component dimensions L x W Medium clip 1 meter length 0 6 mm x 0 3 mm to 5 0 mm x 1 6 mm 16089D Alligator clip leads Four clips 1 meter length Ordering information Agilent 4263B LCR Meter Furnished accessory power cable Options 4263B 001 Add N M DCR Measurement Function 42
3. S he SF 100M N 7 SIX ch IM 7 A 0 85 0 15 0 095 0 36 1 4 ae 4 eas F Fa ok Ri Z N KO 20m 2X0 Zm 14x10 Zm 51x10 Leet 1x10 izm 12 ly 0 85 0 15 0 09 0 16 0 8 1 410 Zm sail 6 P 6 p 6 6 Q 20m 2x0 m 1X10 Zm 19102m 3 710 Zm Z 0 85 0 15 0 09 0 16 0 7 1 1 i T 5 T lt b t e T a t 5 T ai A 20m 2x0 Zm 1X10 Zm 15x10 Zm 31x102 1x10 Zm Ik x 0 85 0 15 0 09 0 16 0 7 1 1 ii Ta Pi T 4 t 4 P 4 E A 2X10 Zm 2x10 Zm 1X10 Zm 1 510 Zm 3X10 Izm 1X10 2m l N 0 85 0 15 0 09 0 16 05 0 83 oe 27am 2 Zm 1 zm 15 Zm 31 2m 10 7 Zo 10 N Z 0 85 0 17 0 12 0 2 0 6 0 97 4 ye 027m 022 mi 01 Zm 018 12mi 0 35 12m 1 3 1 l N 4 0 85 0 4 0 4 0 4 0 6 0 97 ze S 0 02 Zm 0 022 1zm 0 015 1Zm 0 04 iZmi 0 08 1Zmi 0 35 1Zmi 100m S 7 at amp 0 85 0 4 0 4 0 4 0 6 0 97 10m 0 012 1Zmi 0 012Zm 0 00757 12m 0 028 Zmi 0 056 1Zmi 0 26 1Zmi A Im 100H2 120Hz TkH z_ 10klz 100kkz oc 100 120 Ik 10k 20k 100k Frequency Frequency Hz Option 002 only Figure 1 Conversion diagram Table 1 Measurement accuracy of reading Measurement conditions Warm up time 15 min Ambient temperature 23 5 C Test signal voltage 1 Vrms Test cable length 0 meter Open and short corrections performed 6 Measurement time Medium or Long Other test condition data is available in the operation man
4. 63B 002 Add 20 kHz Test Frequency Test fixtures are not furnished as standard Manual options 4263B ABA U S English localization 4263B ABJ Japan Japanese localization 4263B 0OBW Add service manual Cabinet options 4263B 1CM Rackmount kit 4263B 1CN Handle kit Rack flange and handle kit are not compatible Calibration certificate option 4263B 1A7 ISO 17025 compliant calibration 1 Accessories and options are priced individually 2 Manual is not furnished as standard Test fixtures and accessories 16034E G H SMD component test fixture 16043 60011 12 3 terminal SMD test fixture 16044A Test fixture Options 16044A ABA U S English localization 16044A ABJ Japan Japanese localization 16047A E Axial and radial test fixture Options 16047E ABA U S English localization 16047E ABJ Japan Japanese localization 16334A SMD tweezer test fixture 16048A 0 94 meter BNC test leads 16048 60030 0 94 meter SMC test leads 16048D 1 89 meter BNC test leads 16048E 3 8 meter BNC test leads 16060A Transformer test fixture 16065A 200 Vdc external voltage bias fixture 16065C 40 Vdc external voltage bias adapter 16089A Large Kelvin clip leads 16089B Medium Kelvin clip leads 16089C Kelvin IC clip leads 16089D Alligator clip leads 16089E Kelvin clip leads 3 Must specify one of language options ABA or ABJ for operation manual of 16047E for shipment with product Web Resource www agilent com find lIcrmeter
5. Introduction The Agilent Technologies LCR meter makes fast measurements on compo nents It is optimized for applications that require precision and versatility The instrument s performance ranges from general bench top impedance measurements to complex trans former coil and electrolytic capacitor measurements The LCR meter offers fast reliable and versatile testing at a low cost Satisfy your needs for Fast system test throughput e Maximize testing with rapid 25 ms measurements e Minimize user intervention with pass fail testing e Communicate results with display and GPIB e Automate testing with built in handler interface Agilent 4263B LCR Meter 100 Hz to 100 kHz Technical Overview Fault free results e Test with confidence using contact check function e Remove parasitics with error cor rection e Get the best data with 0 1 basic accuracy e Eliminate trigger timing errors with trigger delay function Versatile measurements e Select from 11 impedance parameters e Add three complex transformer parameters with Option 4263B 001 e Set signal level with 5 mVrms resolution e Monitor actual ac voltage and current levels e Pick from many test fixtures and accessories e Save and recall up to ten measurement setups Agg Agilent Technologies Display LCD with back light Displays measurement values instrument states and comparator results Four terminal pair Reduces errors due to cabl
6. e extension Key Parameters and Specifications Test frequencies 100 Hz 120 Hz 1 kHz 10 kHz 100 kHz Option 4263B 002 adds 20 kHz AC test signal levels 20 m 1 Vrms 5 mVrms steps Measurement parameter Select the desired test parameter Monitor actual Trigger mode Choose internal external or manual trigger Pe a edly 5 EA Eede ra abe E SA SA FETA L e 98 E O AS I amp V monitor ac voltage and current levels Frequency Save recall Store and retrieve up to 10 measurement states Cable Extend front panel cable length from 0 to 4 meters Comparator Select values for HIGH Contact check IN and LOW testing Verify reliability of test connections Select one of five test frequencies Open short load Correct for test fixture and cable errors Basic accuracy 0 1 Impedance parameters IZI R X IYI G B L D Q U Option 4263B 001 adds transformer measurement functions turns ratio mutual inductance and dc resistance Cable length settings 0 1 2 4 meters Bias 1 5 and 2 0 Vdc Error correction Open short and load Built in system features GPIB and handler interfaces Measurement time typical 25 ms at best conditions Contact check time typical 5 ms per measurement High quality results System features for test automation Evaluate transformers and coils See five digits of data e Maximize accuracy with error win Option 4263B 001 e Make pr
7. ecise measurements with correction Measure turns ratio mutual 0 1 basic accuracy e Use performance specified with inductance and dc resistance e Select from 11 impedance 0 1 2 and 4 meter cables e Easily make connections with parameters e Test device contact failure with 16060A transformer test fixture e Verify device performance at contact check function e Measure parameter responses with simulated operating conditions e Automate testing with GPIB variable signal levels e Monitor actual test signal voltage interface and current levels e Reduce ground loops with isolated handler interface e Continue testing after ac power loss with continuous memory e Perform pass fail testing with comparator function High In Low Simplify transformer testing Make reliable impedance measurements Make electrolytic capacitor measurements e Obtain versatile testing with a large capacitance range e Keep costs down with built in dc bias source The 4263B LCR meter is designed for e Protect your investment high automated applications energy protection on terminals e Increase test throughput with fast system measurements e Make reliable handler measure ments with contact check function Quickly evaluate electrolytic capacitors Specifications Measurement accuracy gs 0 85 0 15 0 1 0 48 1 9 Accuracy N a W i 8 T i T aa not specified 2 9X10 IZmi 2 9X10 IZmi 5 6X10 iZmi 3 8X10 IZmi 7 7X10 IZmi NS N la
8. s as Agilent Email Updates www agilent com find emailupdates Get the latest information on the products and applications you select Agilent Direct www agilent com find agilentdirect Quickly choose and use your test equipment solutions with confidence Remove all doubt Our repair and calibration services will get your equipment back to you performing like new when promised You will get full value out of your Agilent equipment throughout its lifetime Your equipment will be serviced by Agilent trained techni cians using the latest factory calibration procedures automated repair diagnostics and genuine parts You will always have the utmost confidence in your measurements Agilent offers a wide range of additional expert test and measurement services for your equipment including initial start up assistance onsite education and training as well as design system integration and project management For more information on repair and calibration services go to www agilent com find removealldoubt www agilent com For more information on Agilent Technologies products applications or services please contact your local Agilent office The complete list is available at www agilent com find contactus Americas Canada Latin America United States 877 894 4414 305 269 7500 800 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan
9. ual oF wh For Z Y L C R X G and B accuracy Ae refer to Table 1 Table 1 equations yield accuracy based on frequency and DUT characteristic impedance Zm Zm is from Figure 1 Conversion Diagram D accuracy De Ae 100 Q accuracy Qe where Qm x De lt 1 Qm 2xDe 1 QmxDe U accuracy Ue 0 573 x Ae Ae Accuracy of Z Y L C R X G and B De D accuracy Dm Measured value of D Qe OQ accuracy Qm Measured value of Q Ue U phase angle accuracy Zm DUT impedance at test frequency in Hertz Other Specifications Measurement parameters ranges Parameter Range IZI R X 1 mQ to 100 MQ lY G B 10 nS to 1000S C 1 pF to 1 F L 10 nH to 100 kH D 0 0001 to 9 9999 Q 0 1 to 9999 9 u 180 to 180 A 999 99 to 999 99 Option 4263B 001 DC resistance 1 mQ to 100 MQ Mutual inductance 1 uH to 100 H typical Turns ratio 0 9 to 200 typical Measurement conditions and functions Test frequency 100 Hz 120 Hz 1 kHz 10 kHz 100 kHz Option 4263B 002 adds 20 kHz AC test signal level 20 m 1 Vrms 5 mVrms steps Bias Internal 1 5 and 2 0 Vdc External 0 to 3 0 Vdc Ranging Auto and Hold Trigger nternal Manual and External Trigger delay time 0 to 9999 ms in 1 ms steps Test cable lengths 0 1 meter f lt 100 kHz 2 meter f lt 10 kHz 20 kHz 4 meter f lt 1 kHz Measurement time SHORT MEDIUM 25 ms 65 ms LONG 500 ms