CAIR APM Manual

image

Contents

1. f Setup du Warning For important precautions see page two Caution Do not place the control unit on the floor Position the power cord to keep personnel from tripping over it Remove the existing mattress from the bed Unroll the mattress with the hose connection at the foot end of the bed and the therapy cells facing up Secure the straps on the mattress securely to the movable part of the bed frame If the therapy pad is not already on the mattress place it on the mattress and zip it around the tub Hang the control unit on the foot of the bed facing away from the bed Attach the hoses to the control unit Plug in the control unit and the Standby light will illuminate Press the Power button The control unit will start and the green light will illuminate Keep the control unit ON while the patient is on the mattress Fully inflate the mattress by selecting Autofirm Allow 30 60 minutes for full inflation It is not advisable to inflate the mattress with the patient on it When the mattress is fully inflated select the Static mode and place the patient on the mattress Select the appropriate Comfort Adjust level to prevent bottoming out i e providing greater than one inch of air between the patient s sacral area buttocks and the lower safety mattress as outlined below 1 Begin by placing the head of the bed in the appropriate position based on the patient s Clinical condition
2. User Service Manual Joerns Support Surface Cair APM To avoid injury read user s manual before using transforming wound management E Joerns Support Surfaces Cair APM d Danger To reduce the risk of shock adhere to the Important Precautions Important Notice The equipment must be installed and operated in the manner for which it was intended Facility staff user is responsible for reading and understanding the product user manual and contacting Joerns Healthcare if anything in this manual is unclear Joerns will not be held responsible for any injuries resulting from failure to comply with the instructions and precautions in this manual Warning Joerns specialty support surfaces are designed as mattress replacement systems The risk of entrapment may occur when the equipment is placed on bed frames that leave gaps of even a few inches between the mattress and the head panel foot panel and bed or side rails The equipment is NOT to be used when such gaps are present Facility staff user is responsible for ensuring that all mattresses properly fit the bed frames Joerns is not responsible for the placement of its equipment on bed frames that leave gaps between the mattress and the head panel foot panel or bed or side rails which present a risk of harm to patients Warning An optimal bed system assessment should be conducted on each patient by a qualified clinician or medical provider to
3. The power cord may be wrapped around the unit for convenience Wrap the unit in a plastic bag for dust resistance then store the unit in an area appropriate for an electronic medical device Support Surface Gently roll up the support surface expelling any residual air for temporary storage The mattress should be wrapped in plastic and or a clean bag for storage Joerns Support Surfaces Cair APM System Specifications Weight Control Unit sssri roserne siai 7 Ibs 3 kg Mattress ricse 16 Ibs 7 3 kg Maximum Weight Capacity 350 Ibs 159 kg Dimensions Control Unit 7 5 19 cm W x 12 25 31 cm H x 4 10 cm D Mattress 36 91 cm W x 80 203 cm L x 8 20 cm D Electrical Specifications USA 120V AC 60 Hz 0 6A Risk Class 2G Environmental Conditions Operating Conditions Ambient temperature 10 C to 40 C Relative humidity Non condensing Storage And Shipping Conditions Ambient temperature 10 C to 40 C Relative humidity Non condensing Agency Approvals UL listed Medical Equipment UL60601 1 UL Classification refers to the power unit only not the complete mattress replacement system Call for Assistance If you have any questions or require service ona Joerns product please call Joerns at 800 966 6662 Mattress weight capacity only total weight must not exceed bed frame manufacturers specified load capacity 11 Joerns Support Surfaces Cair APM
4. Joerns Healthcare Warranty Program for Joerns Cair APM Support Surface Joerns Healthcare warrants the Cair APM mattress to be sold free from defects in workmanship and materials under normal and proper use for a period of two 2 years on the mattress and one 1 year on the cover and electromechanical mattress components compressors valves printed circuit boards hoses and couplers Damages arising from improper use will not be covered by this warranty Improper use is defined as but not limited to those caused by Burns Use of improper chemical agents Needle punctures cuts or abrasions Excessive loads Staining Negligent or excessive usage Improper maintenance handling and or cleaning Failure to use in the manner indicated in the Cair APM user manual Any modification repair or alteration done to the Cair APM that was not authorized in writing by Joerns will void this warranty Damage caused by use in unsuitable environmental conditions abuse or failure to maintain the product in accordance with user and service instructions is not covered This warranty is extended to the original purchaser of the equipment Parts Joerns Cair APM contains various parts that wear from normal use Joerns obligation under this warranty is limited to supplying replacement parts servicing or replacing at its option any product which is found by Joerns to be defective When requested by Joerns parts must be re
5. Crisp easy to read graphics for intuitive set up and therapy control Specially designed enclosure for low noise and durability Integrated swing out hanging brackets for fixing to most bed types Suitable for special needs patients in specific clinical specialties Therapy Mattress System Features Twenty individual therapy cells help to evenly distribute the patient s weight and maximize pressure redistribution Modular cell design mattress for ease of cleaning re assembly and cost effective service Specially designed CairLock feature allows mattress to remain inflated without any power up to 12 hours Eight inch deep therapy cells are constructed of highly durable polyurethane coated nylon to provide adequate support and prevent bottoming out for most patients within weight limit Lower safety mattress not required Lower mattress therapy enclosure is constructed from 100 heavy weight 1680 Denier nylon with 1 5 oz Urethane coating and incorporates bed attachment loops for stability Maximum weight capacity of 350 Ibs Anti kink easy clean air supply hose set Quick CPR deflation flag Therapy Pads Many healthcare facilities are facing the challenge of infection control Joerns quilted therapy pads are treated with an antimicrobial to protect the therapy pad from the growth of mold mildew and bacteria Key features and benefits Treated with a highly effective bacteriostatic agent to inhibit the growth of bacte
6. shock fire or personal injury adhere to the following instructions Failure to do so could result in personal injury or equipment damage 1 Use this product only for its intended purpose as described in this manual Only use attachments and or accessories that are recommended by the manufacturer 2 If this product has a damaged power cord or plug is not working properly has been dropped or damaged or has been dropped into water do not operate it For examination and repair return the product to Joerns 3 Keep the control unit and power cord away from heated surfaces e g space heaters 4 Never block the air openings of the product Do not place the control unit on a surface such as a bed or couch where the air opening and or filter compartment located on the back of the control unit may be blocked Keep the air openings free of lint and hair 5 Never drop or insert any object into any opening or hose 6 Do not spill food or liquids onto the control unit If a spill does occur turn off the unit disconnect it from its power supply and allow at least 24 hours for drying 7 Do not use the product outdoors or where aerosol spray products are used 8 Plug this product only into a properly grounded outlet Refer to Grounding Instructions 9 Ensure nothing is placed on the power cord and ensure it is not located where it can be stepped on or tripped over 10 Do not attempt to service the control unit Pl
7. can offer you the expertise assistance and products to bring your facility into compliance Joerns Support Surfaces Cair APM Joerns Compliance Solutions Matching the right bed components in order to meet regulatory guidelines can be complex That is why Joerns offers a wide array of compliance options We assist customers in selecting compliant accessories recommended for their specific bed model Creating a Safer Care Environment While the guidelines apply to all healthcare settings hospitals nursing homes and home care long term care facilities have particular exposure since serious entrapment events typically involve frail elderly or dementia patients For More Information To learn more about compliance options with Joerns products visit our website at www joerns com or contact our Customer Care representatives at 800 826 0270 and ask for free informational publications To learn more about entrapment zones assessment methods and guidelines concerning entrapment contact Joerns Healthcare at 800 826 0270 or consult the FDA website http www fda gov MedicalDevices ProductsandMedicalProcedures GeneralHospitalDevicesandSupplies HospitalBeds default htm Joerns Support Surfaces Cair APM Table of Contents Important Precautions c ccceeeeeeeeeeeeeeeeeeeneeeeee 2 INTFOCUCTION 0 ccccceceecesecneseeesseeeseeceseeeeseeeaueeeeeeeesnaues 4 Shear and Friction Reduction Indications
8. fOr USE ccccseessseeeseeseseeneseeeeseeeeneseenaues 4 Spinal Cord Injury Pressure Redistribution Pain Management Feat reS iisen eaae e rekane enian aaa Eanan a AEEA 5 Therapy Control Unit Features Therapy Mattress System Features Therapy Pads Optional Accessories Grounding INStructions cccccesseeneeeeeeeeeeeeeeenee 6 SetU priiis uurin uaan svcacsenstueceseteeeetesceeessnst 7 Operatii siisi sssospi sna kanamaias s rnna nn sapaka Kaasani 7 Patient Comfort Controls and Monitoring Additional Features c s sssssseseeeeeeeeeeeeeeeeeees 8 CPR CairLock Transport Power Failure Troubleshooting iis ccccceciccescceeccssccsceees ssccteeceesecteecessee 9 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Control Nursing Procedures cccccesseeccesesseeeseeneeeeeeeeeeeeeeneees 9 Recommended Linen Changing the Therapy Pad Patient Positioning and Comfort Incontinence Safety information cccccceeseeneeeeeeeeeeeeeeeeeeeeeeeeeeees 9 Patient Migration Traction Skin Care Bed Height Gloann serre EREE 10 Control Unit General Cleaning Disinfecting Therapy Pad Steam Cleaning Maintenance cccccceceeeeeseeeeeeeeeeeeeeeeeseeeeeeeneeneeeees 10 Storage and Care cececeeeeeceeeeeneeeeeeeeneeeeneeeeneeeeneees 11 Control Unit Support Surface System Specifications ccececeeeeeeeeeeeeeeeeeeeeees 11 Weight Dimensions Electrical Specifications Environmental Condit
9. 2 Select the highest or most firm Comfort Adjust setting 3 Hand Check Place a hand with three 3 fingers if head of bed at 30 or higher or four 4 fingers if head of bed lower than 30 stacked vertically beneath the cells of the mattress and above the safety mattress directly between the lowest point of the patient s sacral area buttocks The smallest finger should be resting on the safety mattress 4 Sequentially reduce the Comfort Adjust setting to the firmness level where the height of the three 3 or four 4 fingers can slide with minimal resistance between the patient s sacral area buttocks and the lower safety mattress This is the proper Comfort Adjust setting for the patient to assure proper inflation of the air cells and prevent bottoming out of the mattress 5 Document the patient s Comfort Adjust setting for future reference and re evaluate with the Hand Check as the patient s condition warrants Joerns Support Surfaces Cair APM dull cath Ce i Ainrin J hel Ld E hed Gott Figure 2 Operation de Warning For important precautions see page two d Caution The patient s head should be positioned in the center of the top section of the mattress When using the mattress system always ensure that the patient is positioned properly within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used Patien
10. adjunct to pain management interventions Note Pressure redistribution and pain management are conditions and diagnoses for which the Cair APM may be indicated Occasionally there are orthopedic and neurological patients that require body positioning to be maintained in specific alignment The use of the Cair APM for these patients should be considered on an individual basis and discussed with the attending physician Features The Cair APM is comprised of two components e Therapy control unit e Therapy mattress system Therapy Control Unit Features Three modes of operation Autofirm Static and Alternate Autofirm mode provides maximum air inflation designed to assist both patients and caregivers during patient transfer and treatment Static mode is a static pressure redistribution mode Alternate mode inflates and deflates the air cylinders in an A B A B pattern that ensures the patient is always supported Five therapeutic comfort control settings to maximize patient compliance and promote healing Closed loop pressure sensor control system eliminates concerns of changes in mattress interface pressure due to ambient temperature and pressure changes Joerns Support Surfaces Cair APM Quick disconnect hose feature allows for rapid attach and CPR deflate at the control unit Automatic panel lock out to avoid unwanted or accidental adjustments Compact lightweight and portable control unit is quiet robust and powerful
11. al side air bolster solution which can enhance the facility s entrapment risk management program Easy to engage Ready Valve for instant inflation and deflation Transfer friendly deflate for ease of assisted transfer or when bolsters are not required Unique contoured design allows ease of ingress egress while providing additional protection and comfort and supporting patient compliance Designed to fit on most key Joerns therapeutic support surfaces Promotes maximum independence by allowing caregiver to decide when added protection is required Cair Rails Inflation Deflation Set the control unit to Autofirm mode or the highest comfort control setting to achieve quick inflation Locate the Ready Valve by unsnapping the flap on the hose set Turn the Ready Valve to inflate or deflate as desired Return the control unit to the desired settings and snap the open flap closed Note CairRails are meant to provide a documentable and functional intervention for the risk management issues of falls and entrapment but in no way guarantee the prevention of falls or entrapment occurrences When using the mattress system always ensure that the patient is positioned properly within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used Grounding Instructions di Warning Use a properly grounded three prong 120V AC outlet for this product Failur
12. cally return to the mode it was in prior to Autofirm in approximately 10 minutes or it can manually be returned to therapy mode once patient has been repositioned Unless contra indicated it is desirable to keep the head of the bed in the low position to provide optimal pressure redistribution and minimize the risk of shearing injuries Elevating Patient into Sitting Position The special properties of the Cair APM therapy pad reduce the opportunity for shear and friction that may occur when raising the head of other beds As with any surface sliding can be expected therefore patients should be repositioned after elevation The knee gatch or foot of the bed may be elevated first to help prevent the patient from sliding when the head of the bed is elevated Incontinence Moisture against the skin surface leads to maceration or softening of the tissues To prevent maceration we recommend you use an incontinence barrier pad to absorb the excess moisture In the event of incontinence or excess drainage on the therapy pad excess fluid should be wiped off the bed surface Safety Information Patient Migration Specialty bed products are designed to redistribute pressure and the shearing friction forces on the patient s skin The risk of gradual movement and or sinking into hazardous positions of entrapment and or inadvertent bed exit may be increased due to the nature of these products Traction With any traction or unstabl
13. d with a mild detergent and warm water If disinfection is desired a combination cleanser disinfectant may be used as explained in Disinfecting section Patient care equipment that does not come in contact with mucous membranes or non contact skin requires low level disinfection Wiping surfaces with a properly prepared detergent or disinfectant carries out low level disinfecting Processing of dirty patient care equipment should take place in a designated area away from clean or sterile supplies and food preparation areas Detergent disinfectants should not be mixed with other germicides or detergents Using the proper dilution ensures the most effective killing power of the disinfectant Wash hands often and well including after removal of gloves Patient care equipment that is used in isolation areas should be disinfected in accordance with all internal policies and procedures regarding such equipment Disinfecting When there is visible soilage and between patients we recommend that the unit and mattress be disinfected with a tuberculocidal disinfectant Disinfectant should be registered with the Environmental Protection Agency EPA e Use rubber gloves and eye protection Prepare detergent disinfectant registered by EPA as hospital disinfectant solution according to instructions on label for correct use dilution With support surface deflated thoroughly wipe down entire mattress as air cells will lie flat Be s
14. djust Comfort Control Make sure the Lockout function is disabled To disable press the up and down Comfort Adjust arrows simultaneously Call Joerns at 800 966 6662 if problem persists Nursing Procedures Recommended Linen Special linens are not necessary for the Cair APM There is no need for a bottom sheet as the therapy pad should be covering the therapy cells at all times The patient should never be lying directly on the therapy cells Based upon the patient specific needs the following linens may be utilized Draw or slide sheet to aid in positioning and to further minimize friction and shearing Incontinence barrier pad for patients incontinent of urine and or stool and patients with heavily draining wounds Top sheet blanket and or bedspread as needed for patient comfort Minimal amount of padding between the patient and bed for optimum performance Changing the Therapy Pad e Place the therapy pad over the therapy cells fitting the corner of the cushions into the corner of the therapy pad Similar to a fitted sheet e Attach the therapy pad to the mattress by zipping it to the mattress tub Patient Positioning and Comfort General Repositioning Patients should be turned and repositioned per individual turning schedule or per facility policy It may be helpful to activate the Autofirm mode to achieve Joerns Support Surfaces Es Cair APM a firm surface for repositioning purposes The unit will automati
15. e fractures maintain physician directed angle of articulation and guard against risks of patient migration or inadvertent deflation of patient surface Skin Care Monitor skin conditions regularly particularly in areas where incontinence and drainage occur or collect and consider adjunct or alternative therapies for high acuity patients Early intervention may be essential to preventing serious skin breakdown Joerns Support Surfaces Cair APM Bed Height To minimize the risks of falls or injury the patient surface should always be in the lowest practical position when the patient is unattended Make sure areas under and around the frame are clear of objects persons and parts of body before ad justing height Cleaning Warning Unplug the control unit from its power source Failure to do so could result in personal injury or equipment damage Warning Do not expose the unit to excessive moisture that would allow for liquid pooling Personal injury or equipment damage could occur Caution Do not use harsh cleansers detergents such as scouring pads and heavy duty grease removers or solvents such as acetone Equipment damage could occur Control Unit Wipe off dust If necessary clean the housing exterior with a disinfectant solution or a mild detergent and a damp cloth Then wipe dry General Cleaning If there is no visible soilage with possible body fluids we recommend that the mattress system be cleane
16. e same time to disengage the Lockout function The Lockout function will return in approximately three minutes Note The unit is designed to lock out all the adjustment controls after the patient has been positioned correctly In approximately three minutes after the last button has been pushed Lockout is enabled Additional Features Warning A possible fire hazard exists This product is suitable for use with oxygen administering equipment of the nasal mask or half bed length tent type only To prevent personal injury or equipment damage ensure that the oxygen tent does not extend below the mattress CPR CPR deflation can be done by disconnecting the hose set from the control unit The mattress will deflate within 30 seconds deflation time varies depending on patient weight and profile Disconnect the hose set from the control unit by pressing both connectors and pulling the hose set away from the control unit To resume therapy reattach the hose set to the control unit Figure 3 CairLock The mattress system comes equipped with our specially designed CairLock therapy connectors to provide greater reliability and comfort In the event of a power failure the connectors can be interlocked together to keep the therapy cells inflated for up to 12 hours Disconnect the two hoses from the control unit and interlock the two ends by pressing them together Figure 4 and Figure 5 Transport To transport the patient
17. e to use a grounded outlet could result in personal injury or damage to equipment or house wiring including risk of fire A qualified electrician should be contacted to correct the wiring and ensure a properly grounded outlet Before installing this product have the electrical system checked to make sure the electrical circuits and the electrical service are properly grounded Having a three prong outlet does not necessarily mean it is grounded Sometimes two prong outlets are replaced with a three prong type even though there is no ground wire There is always a chance of a loose connection or poor installation of a ground wire that causes the loss of proper ground at the outlet Inadequate grounding at electrical outlets can occur even if there is a ground wire Wires can become loose over time at the connection to the outlet Note To install new wires on a circuit requires a qualified electrician How to Determine if Your Outlet has the Proper Grounding Most hardware stores sell circuit testers Figure 1 that can be used to test an outlet for proper grounding The tester plugs into an outlet and by observing the indicator lights one can determine if the outlet is properly grounded For a higher level of assurance an electrician should be requested to thoroughly test the electrical system with more reliable equipment If repair or replacement of the cord or plug is necessary please contact Joerns for assistance
18. ease call Joerns for any service requests 11 The therapy pad top cover of this product is not air permeable and may present a suffocation risk It is the responsibility of the caregiver to ensure that the patient can use this product safely Save These Instructions for Future Reference Bed System Entrapment Information In April 1999 the U S Food and Drug Administration FDA in partnership with representatives from the hospital and post acute bed industry including Joerns Healthcare national healthcare organizations patient advocacy groups and other federal agencies formed the Hospital Bed Safety Workgroup HBSW The workgroup s goal is to improve the safety of bed frames for residents and patients in all health care settings who are most vulnerable to the risk of entrapment The efforts of the FDA and the HBSW culminated in the FDA s release of recommended guidelines intended to reduce the risk of entrapment including dimensional limits for critical gaps and spaces between bed system components and clinical guidance for assessment and implementation of bed side rails in various health care settings Entrapment zones involve the relationship of bed components often directly assembled by the healthcare facility rather than the manufacturer Therefore compliance is the responsibility of the facility As the leading manufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare
19. ensure maximum safety of the patient The assessment should be conducted within the context of and in compliance with the state and federal guidelines related to the use of restraints and bed system entrapment guidance including the Clinical Guidance for the Assessment and Implementation of Side Rails published by the Hospital Bed Safety Workgroup of the U S Food and Drug Administration Further information can be obtained at the following web address http www fda gov MedicalDevices ProductsandMedicalProcedures GeneralHospitalDevicesandSupplies HospitalBeds default htm When using the mattress system always ensure that the patient is positioned properly within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used du Danger Explosion Hazard Do not use in the presence of flammable anesthetics Do not use in the presence of smoking materials or open flame Air flowing through the air mattress will support combustion following instructions Failure to do so could result in personal injury or equipment damage e Immediately after using the Cair APM unplug it from its power source e Do not place or store the product where it can fall or be pulled into a tub or sink e Do not place or drop the product into water or other liquid Do not remove the back of the control unit Refer servicing to Joerns Warning To reduce the risk of burns
20. in bed set mode to Static and turn the control unit off Unplug the power cord from the outlet Transport can be done with the unit plugged into the mattress or by using the CairLock feature Figure 3 Figure 5 Power Failure In the event of a power failure if power is restored within approximately one hour the control unit will return to previous settings If the duration of a power failure extends beyond an hour the control unit will default to Standby mode when power is restored Press Power and reset the preferred mode and comfort level as described in the Operation section In the event of a power failure cells should remain inflated for up to 12 hours In case of an extended power failure transfer the patient to a hospital mattress or other surface In an extended power fail and if the mattress has been in alternate mode we recommend equalization of the air cell pressure by disconnecting the hoses from the control unit and using the CairLock mode Troubleshooting Therapy Surface is Not Inflating Ensure the hose connection from the therapy mattress system mattress to the control unit is securely connected Ensure that the control unit is plugged into an AC outlet Ensure that the power is not on Standby If on Standby press the Power button Ensure that all air cells are connected to the internal mattress manifold Call Joerns at 800 966 6662 if problem persists Unable to Change Therapy Mode or A
21. ion Agency Approvals Call for Assistance cccccceceeeceeeeeceeeeeseeeneaeaeaeeneeees 11 Wana A A E E L T 12 Introduction The Cair APM provided by Joerns Healthcare is a unique therapy system that provides pressure redistribution by alternating pressure between adjacent A B air cells The pressure in the therapy cells automatically alternates on a regular basis to maximize wound healing d Warning The risk of entrapment can arise when equipment is placed on bed frames that leave gaps of even a few inches between the mattress and the head panel foot panel and bed or side rails The equipment is NOT to be used when such gaps are present See Important Precautions section of this manual The Cair APM mattress replacement system is suitable for both the treatment of existing pressure ulcers Stage through Stage IV as well as for those who have been assessed at risk from the complications of immobility The Cair APM is quiet comfortable and simple enough for single caregiver installation The user friendly controls allow for easy adjustment of patient comfort Additionally low friction and low shear materials together with average interface pressures well below capillary closure levels means that the Cair APM meets the comfort and clinical requirements of your patients up to 350 Ibs We have ensured that the Cair APM addresses key areas in the treatment of compromised skin pressure redistribution and reduct
22. ion in both friction and shearing forces Shear and Friction Reduction Shearing occurs when the skin is stationary in relation to the support surface while the underlying tissues and vessels are stretched and damaged When a patient s skin rubs against another surface the result is friction The top surface of the Cair APM therapy pad is constructed from a very smooth nylon fabric with low friction and low shear properties to protect the patient s skin from these damaging forces Indications for Use Note The selection of a pressure redistribution surface needs to be based on each individual patient s clinical condition diagnosis and or co morbidities The choice and use of a support surface is one factor in a holistic program of wound care and treatment Spinal Cord Injury The Cair APM is not recommended for use by patients with unstable spinal fractures Advice should be obtained from the appropriate physician before using the Cair APM system for these patients Pressure Redistribution Rehabilitation Dermatology Amputations Pressure Ulcers Neurology Burns Pain Management AIDS Oncology Arthritis The Cair APM provides distribution of weight over the total body surface area which redistributes pressure against bony prominences and provides desirable immersion and envelopment For patients experiencing severe pain and discomfort due to pressure and or positioning limitations consider the Cair APM as an
23. ria and fungi Constructed from a very smooth nylon fabric with low friction and shear properties to protect the patient s skin from damage Breathable moisture vapor permeable fabric allows air to circulate beneath the pad and wicks away excess moisture This keeps the patient dry and helps to prevent skin maceration Designed for optimal comfort moisture vapor transfer stain resistance and ease of laundering Joerns Support Surfaces Cair APM Optional Accessories Additional therapy pads Quick inflation pump Integrated CairRails risk management side air bolsters two inch side bolsters that inflate on both sides of the patient along the mattress edge to provide additional support and to provide a gentle reminder to the patient that they are near the edge of the mattress Constructed with lower ingress egress area CairRails Integrated CairRails risk management air bolsters offer a bilateral side bolster solution designed to address healthcare s growing concerns of liability in relation to patient falls and entrapment CairRails are being recognized by some of the nation s leading healthcare systems for improving their patient safety and risk management programs CairRails are recommended for patients requiring additional support during patient care and transfer CairRails can help reduce costs while ensuring optimal clinical outcomes and increasing patient safety CairRails Features and Benefits e A bilater
24. t Comfort Controls and Monitoring Figure 2 Power The Power button is used to turn the power on and off Standby The unit starts up in Standby Press the Power button to inflate the mattress When the Standby light is on it may also indicate that there has been a power interruption and the therapy control unit is ready to be turned back on Press the Power button and reset the preferred mode of therapy and comfort level Modes Autofirm Autofirm mode provides maximum air inflation designed to assist both patients and caregivers during patient transfer and treatment The unit will automatically return to the mode it was in prior to Autofirm either Static or Alternate in approximately 10 minutes Therapy Modes Static and Alternating e Static The unit starts in the Static mode which is the standard air therapy e Alternate The air cylinders are inflated and deflated in an A B A B pattern that ensures the patient is always supported E Joerns Support Surfaces Cair APM Comfort Adjust The Comfort Adjust function is located in the center of the control panel The Cair APM can be customized to meet individual patient needs within a therapeutic window See Setup section for more information This function will not work in Autofirm mode Lockout This feature is to prevent any unauthorized changes to the patient settings To unlock and make adjustments to the settings press both up and down comfort arrows at th
25. turned for inspection at the customer s expense Credit will be issued only after inspection Service Most service requests can be handled by the facility Maintenance Department with assistance from the Joerns Product Service Department Most parts requested can be shipped next day air at the customer s expense Should a technician be required one will be provided by Joerns at our discretion Only the Joerns Product Service Department can dispatch authorized technicians Canadian Office 1000 Clarke Road Suite 6 London ON Canada N5V 3A9 P 866 546 1151 F 519 451 8662 2010 Joerns Healthcare 6110078 RevC 10 1208 Post Acute Acute HomeCare VA Government 5001 Joerns Drive 19748 Dearborn Street Stevens Point WI 54481 Chatsworth CA 91311 P 800 826 0270 P 800 966 6662 F 800 457 8827 F 800 232 9796 WW Joerns J IiHealthcare www joerns com email info joerns com
26. ure to reach all areas underneath and in between air cells Allow to air dry If dust or other soiling has accumulated along air hoses remove using swabs moistened with detergent disinfectant as necessary Allow all components to air dry Wrap mattress in plastic and return to storage area Thoroughly wipe down outside of control unit and allow to air dry Cover with plastic and return to storage area Remove gloves and dispose wash hands Therapy Pad The therapy pad can be wiped down with a disinfectant solution or a mild detergent with a damp cloth If heavily soiled the therapy pad can be laundered in a washer and dryer with warm water no more than 120 Fahrenheit A non bleach detergent should be used sparingly Wipe dry or allow to air dry Steam Cleaning Do not use any steam cleaning device on the unit Excessive moisture can damage mechanisms in this unit Maintenance Warning Only facility authorized personnel trained by Joerns should perform preventative maintenance Preventative maintenance performed by unauthorized personnel could result in personal injury or equipment damage Any maintenance done without Joerns s authorization will invalidate any warranties on this product Storage and Care When the product is not in use properly store the power cord Failure to do so could result in personal injury Note Clean the Cair APM as described in the previous section prior to storage Control Unit