Home
APS mini Samostatny cteci modul 1195 ver 1 EN
Contents
1. Program gt End Auit program end The program window is divided into three parts as follows e Reading module status visualisation check of the module wiring correctness e HW address setting e Controls for general module settings The following indicators are located in the status line from the left e PC module communication status red communication errors green no errors e Operation parameter setting progress e Verbal description of the communication status HW address setting The HW address of reading modules is 1 by default To connect multiple reading modules to the communication line set a unique address for each of them To set the address via the communication line from your PC take the following steps e Connect the module s to the communication line e Enter the required address into the HW address input field e Press the Set by card key to make the program send an address setting command the module then waits for about 25s for request confirmation by service card reading the service card may be any card whose code has been entered in the Service card field in the program setting menu this waiting process is indicated by a quick double flash of the red LED in the interval of approximately 2s e Once the service card has been read the program starts communicating normally with the reader Operation parameter setting To set the operation parameters entered in the corresponding input
2. TELEKOMUNIKACE ATEUS APS mn STANDALONE READER MODULE Order No 9134162E User and Service Manual Version 1 0 Introduction Dear customer let us congratulate you on having purchased the ATEUS APS mini Standalone Reader Module We hope that this product will make you happy for a long time Since it is a brand new product which is subject to steady improvements we will be pleased to hear your comments and recommendations if any Module Characteristics The ATEUS APS mini chip card reading module is designed for simple personnel access entry and attendance control applications using chip cards It is composed of a main board and reading antenna for contactless chip card code reading The antenna has a standard form of a blank key module for the ATEUS EntryCom door communicator and so it is easy to install it into the door communicator and extend the same with an ATEUS APS mini module Operation Modes Autonomous programming cards are used for programming the access right database adding and deleting cards Offline a PC is used for programming the access right database and setting the reading module reader operation parameters Online the PC communicates continuously with one reading module or a reading module network up to 16 modules and stores all system events into the archives ATEUS APS mini is designed for all operation modes By default it is equipped with 2 programming car
3. ds for adding and removing user rights without the need to interconnect the reader and the PC autonomous mode The PC based reader controlling software in the offline and online modes can easily be downloaded from www 2n cz the Technical support gt Download section You can also download related user manuals from here To communicate with the reading modules using your PC install an RS485 RS232 RS485 USB or RS485 Ethernet communication converter to the communication line Overview of Module Functions in Operation Modes Operation Mode Anebo Autonomous Offline Online Access right defining by programming cards v v v Card reading and door lock release signalling v v v Acoustic alarm status signalling v v v Change of operation and alarm status parameters v v Access right defining by a PC v v Reading module status visualisation event storing in PC v archives event tracking and processing Reader output control directly by PC v Technical Parameters Dimensions 90 x 55 x 25 mm Weight 0 25 kg Power supply 10 15 VDC Max supply current 150 mA ID technology EM Marin Max count of access cards per memory 500 Input type 2 logic level potential less Output arrangement relay 1C contact 2A 24 V Tamper protecting contact optoelectronic Max reading radius typically 8 cm with ISO chip card Communication channel RS485 galvanically non isolated Signalling 3x LED piezo buzzer Operation temperature range 25 500 Max relative humidity
4. fields of the program press the Write key during communication The process of writing is indicated by the progress indicator in the second part of the status line The APS mini Administrator APS mini Events a APS mini ED programs are designed for the use of ATEUS APS mini modules in the online mode In addition to module parameters programming they allow the user to set up the access rights and to monitor and analyse relevant events e g arrivals and departures of persons You can download the first two programs including user manuals free of charge from www 2n cz Technical Support gt Download the third program can be purchased Access Right Setting by Programming Cards You can also program the access rights of the ATEUS APS mini reading modules without a PC using two programming cards which are included in the module delivery Adding cards to the memory Step 1 Step 2 Step 3 Joo Joo Apply the adding programming Apply sequentially all cards that The reader transits card the reader goes into the are to be assigned the access automatically into the programming mode the yellow right in the particular place standard operation mode LED glows in this mode in approximately 15 s after the last card is applied Deleting cards from the memory Step 1 Step 2 Step 3 JJ a Apply the deleting Apply sequentially all cards from The reader transits programming card the reader which the access right is to be aut
5. max 93 non condensing Installation cable length 1 5m Configurable Operation Parameters Parameter Values to be programmed Lock release timeout 23 259 5 Door ajar delay 2 255s Acoustic signalling time tamper 2 255s Acoustic signalling time door breaking 2 255s Acoustic signalling time door ajar 2 255s Second input function outgoing button handle contact Assembly To assemble the reading module use dowels and appropriate screws Figs 1 2 Pull the interconnecting cable into the tube and connect it to the installation box Having tightened the screws put on the cover to the top and then rotate and press the bottom part until the arresting catches click Figs 3 4 To disassemble the reading module cover release the arresting catches with the key provided in the delivery and remove the cover by moving the bottom part up Figs 4 5 Fig 5 Fig 6 Assembly Recommendations The ATEUS APS mini reading module is based on the passive RF ID technology sensitive to external RF interference This interference can be either radiated from the surrounding environment or conducted Therefore it is not recommended to install the modules near potential electromagnetic field sources such as PC monitors within the distance of up to 3 m or various household and industrial electrical appliances You are also advised to use recommended power supplies linear in o
6. nsmission cables only for the data bus shielded cables or twisted pairs In the last data bus module last line module attach the terminating resistor by inserting a shorting jumper onto contacts S20 Parameter and Access Right Setting by PC ad The APS mini Reader setting software is dcc UE designed for Windows 95 Windows NT 4 0 ODO 4 Status and higher operating systems and requires Last card Code visualisation no installation The program is intended for eo k the offline mode of the reading modules It pe allows you to program_ operation pw Address T I parameters for every ATEUS APS mini a module connected to the RS485 data bus hos Set by cand HW adress t can not be used for access right setting General properties TS To connect the modules to your PC you Strike time po A need either an RS485 RS232 or Door ajar delay 20 RS485 USB communication converter with Tamper signet 33 General automatic communication direction parameter reversal or an RS485 Ethernet converter orced door signal 30 i R i 3 Pug with the following settings 8 data bits even a ase e parity 19 200 bits per second 1 stop bit le Data transfer OK The main program menu contains the following commands Program gt Setting displays settings of the PC COM port and service card code Start Stop PC module communication control Write writes the general parameters to be configured into the reading module
7. omatically into the goes into the programming removed in the particular place standard operation mode mode in approximately 15 s after the last card is applied Clearing of all programmed cards Step 1 Step 2 Step 3 4 JJ JJ Apply the deleting Apply the deleting programming The reader transits programming card the reader card 5 times in a sequence the automatically into the goes into the programming reader clears the card memory standard operation mode mode 2N TELEKOMUNIKACE a s Mod ansk 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz WWW 2n CZ 2005 2N TELEKOMUNIKACE a s Praha OV 1195 v 1
8. rder to minimise conducted interference From this point of view it is also necessary to consider mutual interference of reading modules keep the minimum inter module distance of 50 cm This distance can also be affected negatively by adjacent metallic structures in case of doubts perform a practical on site test before assembling Metal surfaces near the antenna may absorb the electromagnetic field or detune the module antenna and thus impair the proper function and reading distance we recommend you to carry out a practical test in this case too Module Wiring Wire description Colour Meaning Red 12 VDC power supply Blue OV Black RS485 line A conductor White RS485 line B conductor Green RS485 line shield Yellow Input 1 Gray Input 2 Orange NC relay contact Brown C relay contact Violet NO relay contact The reading module inputs must be controlled by a potentialless contact Connecting the input to OV is considered the active status Power supply interconnection The door communicator power supply can be used for supplying the main board advantageously The only condition is that this power supply should have a power reserve for feeding the reader module 150mA and door lock depending on the type The rated voltage of the power supply must be 10 15V dc If the existing power supply fails to comply with these conditions install a new one for the reader Door lock contacts interconnection The relay contacts are u
9. sed for door lock switching Use contacts C and NO for standard locks which unlock by the presence of voltage and contacts C and NC for locks that get unlocked in the case of voltage failure and keep locked while voltage is present Carry voltage from the power supply through these contacts to the door lock If you have a contact on the door that gets activated with the door open carry the contacts to input 1 and OV yellow and blue wire If you do not have this type of contact on your door interconnect the input 1 and OV wires Without this interconnection the door lock would unlock only for approximately 0 5 s because non activated door switch terminals would report an open door The input 2 function can be set for the outgoing button or handle contact The outgoing button is used in the knob knob door mode for opening the door to a person coming from the interior leaving the building The handle contact is used in the knob handle door mode If you do not have the handle contact on your door installed and the door contact is activated on input 1 interconnect the input 2 and OV wires and set the input 2 function at the handle contact By doing so you avoid the broken door alarm message when the door is handle opened from the inside RS485 data bus interconnection You can connect an RS485 data line to the A B and OV wires Up to 16 ATEUS APS mini reading modules can be connected to this three wire line Use data tra
Download Pdf Manuals
Related Search
Related Contents
INSTRUCTION MANUAL SCOT Mode d`emploi Calendrier indicatif KitchenAid KSDB900ESS Installation Guide SGX-CA500 - Pioneer cyclesports Siemens CI24RP00 refrigerator Benchmarking Survey User Manual Version 1.0 January 2011 Web Server Module User`s Manual PART Y: IGW Modeling Tutorial Mode d`emploi Massive 45995/29/17 Copyright © All rights reserved.